Deep brain stimulation (DBS) is a therapy for treating a number of neurological and psychiatric disorders. The treatment involves the implantation of quadripolar electrodes into condition-specific targets in the human brain and injecting electrical pulses across a depth electrode brain interface (EBI). In our previous work (Yousif et al., 2007; Yousif et al., 2008) using a static finite element method (FEM) model solving Laplace’s equation, it was revealed that the resistance of the depth EBI which changes over time post-implantation, has a significant effect on the electric field induced in the surrounding neural tissue. In the present study, we extend our previous EBI model to look at the influence of frequency dependent reactivity of the EBI on the time-varying induced potential distribution, by using the approach of combining a complex FEM model with Fourier analysis. The main finding of the present study is that, once the electric pulses pass through the peri-electrode space, the pulse waveform is distorted, and such distortion is different with changing biophysical properties of the EBI over distinct post-implantation stages. In particular during the acute stage, the interface of lower reactivity behaves similarly to a low-pass filter, and distorts the fast rise and fall of the square pulse; whereas in the chronic stage the stimulating amplitude of the square pulse is reduced >30% by the interface of higher reactivity, and this amplitude slightly falls off during the plateau phase of the waveform (Figure). This indicates that the reactivity of the EBI significantly influences the stimulus waveform in the time domain. In conjunction with our previous studies, we conclude that to make accurate predictions of the stimulation-induced current distribution in the human brain using FEM structural models, both the resistive and reactive components of the EBI need to be taken into account.

Acknowledgements: This work is funded by a grant (id 78512) from the Medical Research Council, UK.

tn_07-29-2008-11-09_86b
tn_86b
07-29-2008-11-09_86b
86b

References

1. Yousif N, Bayford R, Bain PG, Liu X (2007) Brain Research Bulletin 74:361-368

2. Yousif N, Bayford R, Wang S, Liu X (2008) Neuroscience 152:683-691

Conference: Neuroinformatics 2008, Stockholm, Sweden, 7 Sep - 9 Sep, 2008.

Presentation Type: Oral Presentation

Topic: Live Demonstrations

Citation: Yousif N, Bayford R and Liu X (2008). The influence of the reactivity of the electrode-brain interface in therapeutic deep brain stimulation. Front. Neuroinform. Conference Abstract: Neuroinformatics 2008. doi: 10.3389/conf.neuro.11.2008.01.126

Copyright: The abstracts in this collection have not been subject to any Frontiers peer review or checks, and are not endorsed by Frontiers. They are made available through the Frontiers publishing platform as a service to conference organizers and presenters.

The copyright in the individual abstracts is owned by the author of each abstract or his/her employer unless otherwise stated.

Each abstract, as well as the collection of abstracts, are published under a Creative Commons CC-BY 4.0 (attribution) licence (https://creativecommons.org/licenses/by/4.0/) and may thus be reproduced, translated, adapted and be the subject of derivative works provided the authors and Frontiers are attributed.

For Frontiers’ terms and conditions please see https://www.frontiersin.org/legal/terms-and-conditions.

Received: 28 Jul 2008; Published Online: 28 Jul 2008.

* Correspondence: Nada Yousif, Imperial College London, London, United Kingdom, n.yousif@imperial.ac.uk