<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">781566</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2021.781566</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Computational Modelling and Big Data Analysis of Flow and Drug Transport in Microfluidic Systems: A Spheroid-on-a-Chip Study</article-title>
<alt-title alt-title-type="left-running-head">Kheiri et&#x20;al.</alt-title>
<alt-title alt-title-type="right-running-head">Spheroid-Chip Computational Modelling and Analysis</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Kheiri</surname>
<given-names>Sina</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1489918/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kumacheva</surname>
<given-names>Eugenia</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Young</surname>
<given-names>Edmond W.K.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1488329/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<label>
<sup>1</sup>
</label>Department of Mechanical and Industrial Engineering, University of Toronto, <addr-line>Toronto</addr-line>, <addr-line>ON</addr-line>, <country>Canada</country>
</aff>
<aff id="aff2">
<label>
<sup>2</sup>
</label>Department of Chemistry, University of Toronto, <addr-line>Toronto</addr-line>, <addr-line>ON</addr-line>, <country>Canada</country>
</aff>
<aff id="aff3">
<label>
<sup>3</sup>
</label>Institute of Biomedical Engineering, University of Toronto, <addr-line>Toronto</addr-line>, <addr-line>ON</addr-line>, <country>Canada</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1375402/overview">Z. Hugh Fan</ext-link>, University of Florida, United&#x20;States</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/21654/overview">Andrzej Przekwas</ext-link>, CFD Research Corporation, United&#x20;States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1240415/overview">Ting-Yuan Tu</ext-link>, National Cheng Kung University, Taiwan</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Edmond W.K. Young, <email>eyoung@mie.utoronto.ca</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Biosensors and Biomolecular Electronics, a section of the journal Frontiers in Bioengineering and Biotechnology</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>23</day>
<month>11</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="collection">
<year>2021</year>
</pub-date>
<volume>9</volume>
<elocation-id>781566</elocation-id>
<history>
<date date-type="received">
<day>22</day>
<month>09</month>
<year>2021</year>
</date>
<date date-type="accepted">
<day>27</day>
<month>10</month>
<year>2021</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2021 Kheiri, Kumacheva and Young.</copyright-statement>
<copyright-year>2021</copyright-year>
<copyright-holder>Kheiri, Kumacheva and Young</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these&#x20;terms.</p>
</license>
</permissions>
<abstract>
<p>Microfluidic tumour spheroid-on-a-chip platforms enable control of spheroid size and their microenvironment and offer the capability of high-throughput drug screening, but drug supply to spheroids is a complex process that depends on a combination of mechanical, biochemical, and biophysical factors. To account for these coupled effects, many microfluidic device designs and operating conditions must be considered and optimized in a time- and labour-intensive trial-and-error process. Computational modelling facilitates a systematic exploration of a large design parameter space <italic>via</italic> in&#x20;silico simulations, but the majority of in&#x20;silico models apply only a small set of conditions or parametric levels. Novel approaches to computational modelling are needed to explore large parameter spaces and accelerate the optimization of spheroid-on-a-chip and other organ-on-a-chip designs. Here, we report an efficient computational approach for simulating fluid flow and transport of drugs in a high-throughput arrayed cancer spheroid-on-a-chip platform. Our strategy combines four key factors: i) governing physical equations; ii) parametric sweeping; iii) parallel computing; and iv) extensive dataset analysis, thereby enabling a complete &#x201c;full-factorial&#x201d; exploration of the design parameter space in combinatorial fashion. The simulations were conducted in a time-efficient manner without requiring massive computational time. As a case study, we simulated &#x3e;15,000 microfluidic device designs and flow conditions for a representative multicellular spheroids-on-a-chip arrayed device, thus acquiring a single dataset consisting of &#x223c;10 billion datapoints in &#x223c;95&#xa0;GBs. To validate our computational model, we performed physical experiments in a representative spheroid-on-a-chip device that showed excellent agreement between experimental and simulated data. This study offers a computational strategy to accelerate the optimization of microfluidic device designs and provide insight on the flow and drug transport in spheroid-on-a-chip and other biomicrofluidic platforms.</p>
</abstract>
<kwd-group>
<kwd>organ-on-a-chip</kwd>
<kwd>cancer spheroids</kwd>
<kwd>drug delivery</kwd>
<kwd>full-factorial experiments</kwd>
<kwd>microfluidic design space exploration</kwd>
<kwd>hierarchical clustering</kwd>
</kwd-group>
<contract-sponsor id="cn001">Natural Sciences and Engineering Research Council of Canada<named-content content-type="fundref-id">10.13039/501100000038</named-content>
</contract-sponsor>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction</title>
<p>Over the past few decades, microfluidics (MFs) has emerged as a powerful platform for fundamental and applied research in cell biology, soft robotics, medicine, drug screening, materials science, and analytical chemistry (<xref ref-type="bibr" rid="B57">Whitesides, 2006</xref>; <xref ref-type="bibr" rid="B54">Tian and Finehout, 2009</xref>; <xref ref-type="bibr" rid="B60">Young et&#x20;al., 2012</xref>; <xref ref-type="bibr" rid="B41">Pak et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B44">Rajendra et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B36">Moore et&#x20;al., 2017</xref>; <xref ref-type="bibr" rid="B19">Humayun et&#x20;al., 2018</xref>; <xref ref-type="bibr" rid="B23">Khuu et&#x20;al., 2019</xref>; <xref ref-type="bibr" rid="B12">Gevorkian et&#x20;al., 2021</xref>). For all applications, the design of an MF device with optimized geometry is a vital first step of the engineering process, but the optimization process is usually conducted in a trial-and-error manner and is, therefore, time- and labour-intensive (<xref ref-type="bibr" rid="B3">Chakraborty, 2010</xref>; <xref ref-type="bibr" rid="B18">Huang, 2013</xref>). Many factors have to be considered and tested, such as the geometry and dimensions of microchannels or microwells, operating conditions such as fluid flow rates, and fluid properties. It is highly desirable to utilize a rational approach to the design process that would reduce the number of experimental trials and make it more time-efficient.</p>
<p>Computational modelling enables systematic exploration of a large parameter space <italic>via</italic> in&#x20;silico simulations aimed at the optimization of the design and operation of an MF device prior to experiments (<xref ref-type="bibr" rid="B10">Enderling and Rejniak, 2013</xref>). In silico simulations have been extensively used for lab-on-a-chip platforms to simulate fluid flow and transport phenomena, including droplet formation (<xref ref-type="bibr" rid="B50">Sontti and Atta, 2017</xref>, <xref ref-type="bibr" rid="B51">2020</xref>; <xref ref-type="bibr" rid="B35">Mohamed et&#x20;al., 2019</xref>), micro-mixing (<xref ref-type="bibr" rid="B61">Zhang et&#x20;al., 2008</xref>; <xref ref-type="bibr" rid="B53">Suh and Kang, 2010</xref>), bacteria growth and culture (<xref ref-type="bibr" rid="B15">Hohne et&#x20;al., 2009</xref>; <xref ref-type="bibr" rid="B56">Westerwalbesloh et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B26">Kim et&#x20;al., 2019</xref>; <xref ref-type="bibr" rid="B22">Kheiri et&#x20;al., 2020</xref>), particle sorting and separation (<xref ref-type="bibr" rid="B14">Han et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B31">Lu and Xuan, 2015</xref>; <xref ref-type="bibr" rid="B2">Amin Arefi et&#x20;al., 2020</xref>; <xref ref-type="bibr" rid="B11">Fallahi et&#x20;al., 2020</xref>), biomechanical forces (<xref ref-type="bibr" rid="B24">Kim et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B45">Rousset et&#x20;al., 2017</xref>), and drug delivery (<xref ref-type="bibr" rid="B16">Hossain et&#x20;al., 2012</xref>; <xref ref-type="bibr" rid="B48">Soltani and Chen, 2012</xref>; <xref ref-type="bibr" rid="B49">Soltani et&#x20;al., 2016</xref>; <xref ref-type="bibr" rid="B8">d&#x2019;Esposito et&#x20;al., 2018</xref>). In the specific case of MF devices for cell biology studies, computational fluid dynamics (CFD) was used to investigate molecular transport in a bilayer membrane-based MF device and examine the effect of flow-induced shear stress on endothelial cells (<xref ref-type="bibr" rid="B58">Wong et&#x20;al., 2017</xref>). The CFD model provided guidelines for the design of MF devices operating within a range of physiological shear stresses while ensuring efficient transport of biomolecules through the membrane. In another computational study, a mathematical model coupled with numerical simulations led to an optimal design of MF devices for studies of endothelial cell migration and angiogenesis (<xref ref-type="bibr" rid="B27">Kuzmic et&#x20;al., 2019</xref>). A computational framework was established to elucidate the effect of MF device geometry on cell migration and angiogenesis in a double-channel design with interconnected migration ports. Several studies have focused on the simulations of drug delivery to multicellular tumour spheroids (MCTSs) in a spheroid-on-a-chip platform (<xref ref-type="bibr" rid="B25">Kim et&#x20;al., 2008</xref>; <xref ref-type="bibr" rid="B37">Moshksayan et&#x20;al., 2018</xref>). More specifically, these simulations explored the effect of MF device geometry including microwell and microchannel dimensions on drug supply and uptake by MCTSs. Recently, a numerical study of the design of a tumour-on-a-chip platform was performed to determine its optimal performance in screening multidrug combinations (<xref ref-type="bibr" rid="B13">Hajari et&#x20;al., 2021</xref>).</p>
<p>In the vast majority of numerical studies, the in-silico models are generally applied to a small set of conditions or parametric levels and employed only for &#x201c;one-factor-at-a-time&#x201d; (OFAT) experimental designs. For example, in modelling and simulating bacteria growth and glucose transport to bacterial colonies on-chip, the effect of glucose concentration was simulated while all other parameters were maintained invariant (<xref ref-type="bibr" rid="B56">Westerwalbesloh et&#x20;al., 2015</xref>). Similarly, the effect of fluid flow and viscosity was modelled to study cancer cell loading in microwells of the MF device (<xref ref-type="bibr" rid="B13">Hajari et&#x20;al., 2021</xref>). Inlet fluid flow rate and viscosity were varied systematically across three different values and thus nine parameter combinations were used overall, but the geometric characteristics of the MF device and MCTS properties were left constant to reduce the parameter space. Generally, computational models were treated as in&#x20;silico analogs of experimental setups to simulate an experiment that could have been conducted using standard OFAT or factorial experimental designs. While such numerical studies hold great promise by i) simulating the output result without running an experiment and ii) providing a greater analytical power than is possible with experiments, these models would offer an even greater benefit if a larger parameter space could be explored. By definition, full factorial design (FFD) investigates the effects of all the selected factors and their interactions on the outcome(s) of the experiment (<xref ref-type="bibr" rid="B7">Das and Dewanjee, 2018</xref>). The term &#x201c;full-factorial&#x201d; refers to the fact that once the various factors of interest and the different levels within each factor have been selected, every conceivable combination of levels in the parameter space will be simulated and analyzed; this is distinct from &#x201c;fractional factorial design,&#x201d; where only a fraction or subset of the parameter space is tested and analyzed. Such simulations may reveal the most effective design and operating parameters that have not been considered or experimentally explored. For spheroid-on-a-chip MF platforms, the need for optimization is particularly important, as modifications of the geometry of the MF devices can significantly affect cell culture microenvironment and, subsequently, impact cell aggregation and MCTS structure and fate (<xref ref-type="bibr" rid="B59">Young and Beebe, 2010</xref>; <xref ref-type="bibr" rid="B38">Ong et&#x20;al., 2017</xref>; <xref ref-type="bibr" rid="B62">Zuchowska et&#x20;al., 2017</xref>). An approach in which MCTS culture and drug delivery conditions are &#x201c;screened&#x201d; in a time- and labour-efficient manner would be highly advantageous, as numerous operating conditions and geometrical constraints create a large parameter space in MF spheroid-on-a-chip platforms. Here, we report an efficient computational strategy for simulating fluid flow and transport of low-molecular-weight solutes (drugs) in an MF spheroid-on-a-chip platform (<xref ref-type="bibr" rid="B55">Wang et&#x20;al., 2016</xref>). The platform is comprised of a large array of MCTSs compartmentalized in cylinder-shaped microwells connected with a common channel used for the continuous supply of cell culture medium and/or drug solution to the MCTSs (<xref ref-type="bibr" rid="B39">Ota et&#x20;al., 2011</xref>; <xref ref-type="bibr" rid="B47">Schneider et&#x20;al., 2013</xref>; <xref ref-type="bibr" rid="B55">Wang et&#x20;al., 2016</xref>). We show that based on (&#x3e;15,000) MF device designs and flow conditions acquired in a single dataset across a large parameter space (operating conditions, geometrical constraints, and different material porosity), these simulations can be effectively utilized to identify the most effective MF device design. The computational strategy combined and utilized four key factors: i) the governing physical equations; ii) parametric sweeping; iii) parallel computing; and iv) extensive dataset analysis, which all together enable a complete &#x201c;full-factorial&#x201d; exploration of the design parameter space in a combinatorial fashion. Importantly, the simulations were conducted in a time-efficient manner without requiring massive computational time. The computational model integrated multiple physical interfaces to examine advective and diffusive modes of drug delivery to MCTSs in MF devices with various geometries and examined the impact of MF device design on drug transport. This study demonstrates the power of the computational strategy and offers insights on drug transport phenomena in MF devices under a broad range of experimental conditions and MF device designs.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>Materials and Methods</title>
<p>The overall workflow of the computational framework (<xref ref-type="fig" rid="F1">Figure&#x20;1</xref>) consists of five major stages: i) definition of the MF device geometry or design selection, ii) construction of the in-silico model, which involves mesh generation, specification of the governing equations, and selection of the values or levels of all factors, iii) parametric sweeping across the entire parameter space, iv) parallel computing, and v) post-processing and analysis. The computational model was built using COMSOL Multiphysics 5.5 software (COMSOL, Stockholm, Sweden), a finite-element-based commercial CFD package. To capture the set of governing equations needed to model flow and molecular transport, two distinct COMSOL physics interfaces were coupled together, namely 1) the Laminar Flow (<italic>spf</italic>) interface and 2) the Transport of Diluted Species (<italic>tds</italic>) interface. An automatic solution-adaptive mesh refinement tool was used to regenerate the mesh and maintain mesh quality within an acceptable range for all simulations (<xref ref-type="sec" rid="s10">Supplementary Material</xref>). The criterion for convergence in the simulations was selected to be a drop of four orders of magnitude <inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mn>10</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>4</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Computational modelling workflow for microfluidic design optimization, involving: (1) design selection, (2) model construction including mesh generation, specification of governing equations, and selection of parametric levels, (3) parametric sweeping, (4) parallel computing, and (5) post-processing and analysis.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g001.tif"/>
</fig>
<sec id="s2-1">
<title>MF Device Geometry: Our Spheroid-on-a-Chip Model</title>
<p>Array-type MF devices have been extensively used for spheroid formation and drug screening (<xref ref-type="bibr" rid="B30">Liu et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B46">Sabhachandani et&#x20;al., 2016</xref>; <xref ref-type="bibr" rid="B37">Moshksayan et&#x20;al., 2018</xref>). They can accommodate hundreds of cell-laden droplets in the microwells (<xref ref-type="bibr" rid="B55">Wang et&#x20;al., 2016</xref>; <xref ref-type="bibr" rid="B17">Huang et&#x20;al., 2017</xref>). As a case study, our computational study focused on a particular design shown schematically in <xref ref-type="fig" rid="F2">Figure&#x20;2</xref>. The MF device consists of parallel rows of cylindrical microwells positioned on a side of a microchannel &#x201c;supply line.&#x201d; The parallel rows of channels are connected to a single inlet and a single outlet <italic>via</italic> serial divisions. Cell-laden droplets are compartmentalized in the microwells, and subsequently, transform into MCTSs embedded in a hydrogel scaffold. The geometry of the microwells determines droplet size, which in turn, controls MCTS dimensions (<xref ref-type="bibr" rid="B21">Kaminski and Garstecki, 2017</xref>). This MF platform has the following advantages: i) the capability to form uniformly sized MCTSs, ii) the ability to monitor individual MCTSs in real-time, and iii) long-term MCTS culture, enabled by the use of a suitable hydrogel scaffold. Because droplet generation is controlled by the relationship between the channel geometry and the microwell aspect ratio (<xref ref-type="bibr" rid="B47">Schneider et&#x20;al., 2013</xref>), the design of such MF devices to study, for example, the biomechanical forces exerted on the MCTSs or drug delivery to the MCTSs is a challenging task. While the effect of MF device geometry on droplet formation has been studied (<xref ref-type="bibr" rid="B6">Cohen et&#x20;al., 2010</xref>), the effect of these constraints on fluid flow and transport of biological molecules such as drugs or nutrients has yet to be examined (<xref ref-type="bibr" rid="B28">Lee et&#x20;al., 2012</xref>; <xref ref-type="bibr" rid="B47">Schneider et&#x20;al., 2013</xref>; <xref ref-type="bibr" rid="B55">Wang et&#x20;al., 2016</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Spheroid-on-a-chip device design and geometry. <bold>(A)</bold> 3D illustration of the array-based spheroid-on-chip microfluidic device used in this study. <bold>(B)</bold> Illustration of single supply channel (SSC) and double supply channel (DSC) designs of the spheroid-on-a-chip device. <bold>(C,D)</bold> Geometric parameters considered in the design optimization of the SSC and DSC spheroid-on-a-chip designs.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g002.tif"/>
</fig>
<p>Here, our goal was to simulate the effects of geometrical and non-geometrical constraints on the transport of drugs and nutrients to the arrays of MCTSs in the spheroid-on-a-chip MF platform illustrated in <xref ref-type="fig" rid="F2">Figure&#x20;2A</xref>. In all simulations, MCTS diameter was 100&#xa0;&#xb5;m. To demonstrate the versatility of our computational strategy, we studied both the single-supply-channel (SSC) design (shown in <xref ref-type="fig" rid="F2">Figure&#x20;2A</xref>) and a modified double-supply-channel (DSC) design that has not been reported (<xref ref-type="fig" rid="F2">Figure&#x20;2B</xref>). Five different geometric parameters of the MF device were examined, each with a specific range of values (<xref ref-type="table" rid="T1">Table&#x20;1</xref>
<bold>)</bold>.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Geometrical, material, and operating conditions used in current spheroid-on-a-chip design study.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameter</th>
<th align="center">Notation</th>
<th align="center">Range</th>
<th align="center">Steps</th>
<th align="center">Number of conditions</th>
<th align="center">References</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Inlet velocity left</td>
<td align="center">Q<sub>1</sub>
</td>
<td align="left">0.01&#x2013;0.02&#xa0;ml/h</td>
<td align="left">0.01, 0.02&#xa0;ml/h</td>
<td align="center">2</td>
<td align="left">
<xref ref-type="bibr" rid="B42">Patra et&#x20;al. (2016)</xref>; <xref ref-type="bibr" rid="B37">Moshksayan et&#x20;al. (2018)</xref>
</td>
</tr>
<tr>
<td align="left">Inlet velocity right</td>
<td align="center">Q<sub>2</sub>
</td>
<td align="left">0.01&#x2013;0.02&#xa0;ml/h</td>
<td align="left">0.01, 0.02&#xa0;ml/h</td>
<td align="center">2</td>
<td align="left">
<xref ref-type="bibr" rid="B42">Patra et&#x20;al. (2016)</xref>; <xref ref-type="bibr" rid="B37">Moshksayan et&#x20;al. (2018)</xref>
</td>
</tr>
<tr>
<td align="left">Infusion width left</td>
<td align="center">W<sub>L</sub>
</td>
<td align="left">&#x223c;0&#x2013;60&#xa0;&#xb5;m</td>
<td align="left">0.1, 20, 30, 40, 60&#xa0;&#xb5;m</td>
<td align="center">5</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Cohen et&#x20;al. (2010)</xref>; <xref ref-type="bibr" rid="B40">Ota et&#x20;al. (2010)</xref>; <xref ref-type="bibr" rid="B32">McMillan et&#x20;al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">Infusion width right</td>
<td align="center">W<sub>R</sub>
</td>
<td align="left">20&#x2013;60&#xa0;&#xb5;m</td>
<td align="left">20, 30, 40, 60&#xa0;&#xb5;m</td>
<td align="center">4</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Cohen et&#x20;al. (2010)</xref>; <xref ref-type="bibr" rid="B40">Ota et&#x20;al. (2010)</xref>; <xref ref-type="bibr" rid="B32">McMillan et&#x20;al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">Infusion height left</td>
<td align="center">H<sub>L</sub>
</td>
<td align="left">&#x223c;0&#x2013;60&#xa0;&#xb5;m</td>
<td align="left">0.1, 20, 30, 40, 60&#xa0;&#xb5;m</td>
<td align="center">5</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Cohen et&#x20;al. (2010)</xref>
</td>
</tr>
<tr>
<td align="left">Infusion height right</td>
<td align="center">H<sub>R</sub>
</td>
<td align="left">20&#x2013;60&#xa0;&#xb5;m</td>
<td align="left">20, 30, 40, 60&#xa0;&#xb5;m</td>
<td align="center">4</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Cohen et&#x20;al. (2010)</xref>
</td>
</tr>
<tr>
<td align="left">Chamber radius</td>
<td align="center">R</td>
<td align="left">80&#x2013;160&#xa0;&#xb5;m</td>
<td align="left">80, 120, 160&#xa0;&#xb5;m</td>
<td align="center">3</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Cohen et&#x20;al. (2010)</xref>
</td>
</tr>
<tr>
<td align="left">Porosity</td>
<td align="center">
<inline-formula id="inf2">
<mml:math id="m2">
<mml:mi>&#x3c6;</mml:mi>
</mml:math>
</inline-formula>
</td>
<td align="left">0.2&#x2013;0.9</td>
<td align="left">0.2, 0.5, 0.7, 0.9</td>
<td align="center">4</td>
<td align="left">
<xref ref-type="bibr" rid="B20">Hwang et&#x20;al. (2010)</xref>
</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2-2">
<title>Governing Physical Equations</title>
<p>Molecular transport was modeled as time-dependent and three-dimensional, and included advection and mass transfer in the porous domain. Molecular transport was thus governed by the advection-diffusion equation:<disp-formula id="e1">
<mml:math id="m3">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>c</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>S</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>D</mml:mi>
<mml:msup>
<mml:mo>&#x2207;</mml:mo>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mi>c</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi mathvariant="bold-italic">u</mml:mi>
<mml:mo>&#x22c5;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>where <inline-formula id="inf3">
<mml:math id="m4">
<mml:mrow>
<mml:mo>&#xa0;</mml:mo>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the species concentration (mol/m<sup>3</sup>), <inline-formula id="inf4">
<mml:math id="m5">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the supply influx (mol/m<sup>3</sup>&#x22C5;s), <inline-formula id="inf5">
<mml:math id="m6">
<mml:mrow>
<mml:mo>&#xa0;</mml:mo>
<mml:mi mathvariant="bold-italic">u</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the fluid velocity (m/s), and <inline-formula id="inf6">
<mml:math id="m7">
<mml:mi>D</mml:mi>
</mml:math>
</inline-formula> is the diffusion coefficient of the molecular species (m<sup>2</sup>/s). Fluid flow was considered time-dependent, three-dimensional, laminar, and incompressible, and was thus governed by the continuity and Navier-Stokes equations:<disp-formula id="e2">
<mml:math id="m8">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>&#x3c1;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2b;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mo>.</mml:mo>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:mi mathvariant="bold-italic">u</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>
<disp-formula id="e3">
<mml:math id="m9">
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi mathvariant="bold-italic">u</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="bold-italic">u</mml:mi>
<mml:mo>&#x22c5;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mi mathvariant="bold-italic">u</mml:mi>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>&#x3bc;</mml:mi>
<mml:msup>
<mml:mo>&#x2207;</mml:mo>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mi mathvariant="bold-italic">u</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>&#x3c1;</mml:mi>
<mml:mi mathvariant="bold-italic">f</mml:mi>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>where <inline-formula id="inf7">
<mml:math id="m10">
<mml:mrow>
<mml:mtext>&#xa0;</mml:mtext>
<mml:mi>&#x3c1;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the fluid density (kg/m<sup>3</sup>); <inline-formula id="inf8">
<mml:math id="m11">
<mml:mi mathvariant="bold-italic">u</mml:mi>
</mml:math>
</inline-formula> is the fluid velocity (m/s), <inline-formula id="inf9">
<mml:math id="m12">
<mml:mrow>
<mml:mtext>&#xa0;</mml:mtext>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the pressure (Pa), <inline-formula id="inf10">
<mml:math id="m13">
<mml:mi>&#x3bc;</mml:mi>
</mml:math>
</inline-formula> is the dynamic viscosity of the fluid (Pa&#x22C5;s), and <inline-formula id="inf11">
<mml:math id="m14">
<mml:mi mathvariant="bold-italic">f</mml:mi>
</mml:math>
</inline-formula> is the body force per unit volume (N/m<sup>3</sup>). <xref ref-type="disp-formula" rid="e2">Eqs 2</xref> and <xref ref-type="disp-formula" rid="e3">3</xref> represent conservation of mass (continuity equation) and momentum (Navier-Stokes equations), respectively. Here we assumed the body force term was zero as we ignored gravity and assumed there were no other external field-induced forces present. To study drug transport and penetration into spheroids, the spheroids in our simulations were treated as porous media (defined as a &#x201c;matrix domain&#x201d; in COMSOL) surrounded by the primary fluid domain where MF flow was occurring. Porous media flow within the spheroid was governed by:<disp-formula id="e4">
<mml:math id="m15">
<mml:mrow>
<mml:mfrac>
<mml:mo>&#x2202;</mml:mo>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:msub>
<mml:mi>&#x3b5;</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mo>.</mml:mo>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:mi mathvariant="bold-italic">v</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">Q</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>where <inline-formula id="inf12">
<mml:math id="m16">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b5;</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the porosity (or void fraction) of the matrix domain, <inline-formula id="inf13">
<mml:math id="m17">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#xa0;v</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the velocity inside the matrix domain, and <inline-formula id="inf14">
<mml:math id="m18">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">Q</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is a mass source within the matrix domain (kg/m<sup>3</sup>&#xb7;s). The velocity field within the porous domain can be calculated using Darcy&#x2019;s law:<disp-formula id="e5">
<mml:math id="m19">
<mml:mrow>
<mml:mi mathvariant="bold-italic">v</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mi>&#x3ba;</mml:mi>
<mml:mi>&#x3bc;</mml:mi>
</mml:mfrac>
<mml:mo>&#x2207;</mml:mo>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:math>
<label>(5)</label>
</disp-formula>where &#x3ba; and <inline-formula id="inf15">
<mml:math id="m20">
<mml:mi>&#x3bc;</mml:mi>
</mml:math>
</inline-formula> are the permeability of the porous material (m<sup>2</sup>) and dynamic viscosity of the fluid material (Pa&#x22C5;s), respectively. Solving the velocity field within the matrix domain determined the advection mode of drug transport. The diffusion mode of transport, in contrast, was calculated using Fick&#x2019;s law:<disp-formula id="e6">
<mml:math id="m21">
<mml:mrow>
<mml:mi mathvariant="bold-italic">J</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2212;</mml:mo>
<mml:mtext>D</mml:mtext>
<mml:mo>&#x2207;</mml:mo>
<mml:mi mathvariant="italic">c</mml:mi>
</mml:mrow>
</mml:math>
<label>(6)</label>
</disp-formula>where <inline-formula id="inf16">
<mml:math id="m22">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
<mml:mi mathvariant="bold-italic">J</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the diffusive flux (mol/m<sup>2</sup>&#x22C5;s), which points in the negative direction of the concentration gradient. Finally, drug transport was solved through mass conservation in which both advection and diffusion modes of transport were included using the following:<disp-formula id="e7">
<mml:math id="m23">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi mathvariant="italic">c</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2b;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mo>&#x22c5;</mml:mo>
<mml:mi mathvariant="bold-italic">J</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="italic">v</mml:mi>
<mml:mo>&#x22c5;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mi mathvariant="italic">c</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>R</mml:mi>
</mml:mrow>
</mml:math>
<label>(7)</label>
</disp-formula>where <inline-formula id="inf17">
<mml:math id="m24">
<mml:mi>R</mml:mi>
</mml:math>
</inline-formula> is the drug reaction rate (mol/m<sup>3</sup>&#x22C5;s). This reaction rate was set to zero in all our simulations.</p>
</sec>
<sec id="s2-3">
<title>Parametric Sweeping</title>
<p>To tackle this large combinatorial problem of &#x3e;15,000 modelling scenarios, we employed parallel computing using the CAD Compute Cluster from CMC Microsystems and divided the various scenarios into smaller subsets to be run simultaneously on different parallel processors (<xref ref-type="bibr" rid="B1">Afzal et&#x20;al., 2017</xref>). Using this large computational resource (eight nodes, Dual 14-core, 2.4&#x2013;3.3&#xa0;GHz CPU), the total computational time was reduced &#x223c;10-fold compared to running the same CFD simulation on a single desktop workstation (7-core, 2.1&#x2013;3.2&#xa0;GHz&#x20;CPU).</p>
</sec>
<sec id="s2-4">
<title>Post-Processing and Analysis</title>
<p>For all simulations, pressure, velocity, and concentrations were analyzed and evaluated in 2D and 3D configurations. The 2D and 3D plots were generated using COMSOL Multiphysics plotting functions. For 1D plotting and investigation, the data were extracted and exported from the CFD model using volume averaged evaluation functions. Five key metrics of flow and transport in the spheroid domain were extracted: concentration, velocity, shear rate, advective flux, and diffusive flux. These metrics were normalized between 0 and 1 before being compiled into heatmaps. Clustered heatmaps were generated based on the exported data and post-processing by the Seaborn library and clustering functions in Python (<xref ref-type="sec" rid="s10">Supplementary Material</xref>). For convenience of describing specific device designs, we established a naming convention based on the concatenation of the six design parameters selected for the given design. An executable standalone application was also designed and created using the application builder module in COMSOL Compiler (<xref ref-type="sec" rid="s10">Supplementary Material</xref>).</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>Results and Discussion</title>
<sec id="s3-1">
<title>Velocity and Pressure Distribution in a Single Row of Microwells</title>
<p>We conducted numerical simulations with our model to examine the effects of different parameters on biomechanical forces, fluid transport, and drug uptake in and around tumour spheroids cultured on-chip. First, a single row of the device, which includes 50 microwells, was modeled to determine the steady state pressure gradient and velocity field in the microchannel (<xref ref-type="sec" rid="s10">Supplementary Figure S4</xref>). Using a prescribed inlet flow rate of 0.01&#xa0;ml/h, we found the maximum pressure in the microchannel to be 17.5&#xa0;Pa and confirmed that the pressure drop between any two adjacent microwells was consistent along the entire length of the microchannel (<xref ref-type="sec" rid="s10">Supplementary Figure S4A</xref>). Fluid velocity inside the microwells was &#x223c;10&#xd7; lower compared to the fluid velocity in the main microchannel (<xref ref-type="sec" rid="s10">Supplementary Figure S4B</xref>
<bold>)</bold>. Notably, the velocity magnitudes inside the chambers were found to be &#x223c;0.02&#xa0;mm/s (<xref ref-type="sec" rid="s10">Supplementary Figure S4C</xref>), consistent with typical physiological conditions in tumour tissue (<xref ref-type="bibr" rid="B4">Chary and Jain, 1989</xref>).</p>
<p>To explore a larger design space, we examined the DSC design consisting of two parallel supply microchannels on either side of the spheroid-containing microwells (<xref ref-type="fig" rid="F3">Figure&#x20;3A</xref>). Note the DSC design consisted of the same set of geometrical parameters and range of values as the SSC design. Flow rates for both channels were first prescribed at 0.01&#xa0;ml/h. Under this condition, velocity magnitudes inside the spheroid chambers were &#x223c;0.02&#xa0;mm/s, similar to the SSC design (<xref ref-type="fig" rid="F3">Figure&#x20;3B</xref>). We examined fluid flow circulation inside the microwell (<xref ref-type="fig" rid="F3">Figures 3C,D</xref>
<bold>)</bold> and found that the streamlines formed two flow vortices that surrounded the spheroid. These vortices in the DSC device were not observed in the SSC design <bold>(</bold>
<xref ref-type="sec" rid="s10">Supplementary Figure S2</xref>
<bold>)</bold>. Furthermore, adding the second supply microchannel not only improved circulation of the fluid inside the microwell, but also improved the uniform distribution of surface shear forces on the spheroid (<xref ref-type="fig" rid="F3">Figure&#x20;3E)</xref> compared to the SSC design (<xref ref-type="sec" rid="s10">Supplementary Figure S2</xref>). We next simulated fluid flow inside the spheroids (treated as a porous medium) to better understand the effects of adding the second supply microchannel to flow through the internal spaces of the spheroid (<xref ref-type="fig" rid="F3">Figure&#x20;3F</xref>). We found that fluid motion had two high velocity regions corresponding to the locations closest to the supply microchannels on the two sides, while the rest of the spheroid observed velocity magnitudes that were an order of magnitude lower. Taken together, these initial simulations revealed several major differences between SSC and DSC designs that motivated further exploration into ways to optimize the design to achieve maximum drug transport efficiency for the purposes of developing a rapid high-throughput spheroid drug screening tool. Before conducting such a massive design space exploration, however, we experimentally validated our computational model by using the actual spheroid-on-a-chip platform and the select experimental flow conditions.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Representative results of flow and transport simulations in COMSOL. <bold>(A)</bold> A single unit of the double-supply channel (DSC) design of the spheroid-on-a-chip device, consisting of the microwell for spheroid formation and culture, two supply channels, two connecting channels, and the spheroid itself (shown in yellow). <bold>(B,C)</bold> Velocity streamlines in the DSC device. <bold>(D)</bold> Velocity vectors showing fluid flow circulation overlaying streamlines of flow in the microwell. <bold>(E)</bold> Velocity magnitude of fluid flow on the surface of the spheroid, shown as arrow surface and surface contours. <bold>(F)</bold> Velocity vectors within the spheroid (treated as porous medium).</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g003.tif"/>
</fig>
</sec>
<sec id="s3-2">
<title>Experimental Validation of the Computational Model</title>
<p>We conducted a series of experiments to validate our computational model, using an SSC array-type MF device to form MCF-7 breast cancer MCTSs and examine the effect of different flow rates on drug uptake. The experimental MF device contained 200 MCTSs in the microwells that were organized in four parallel rows (<xref ref-type="fig" rid="F4">Figure&#x20;4A</xref>). The microwells were connected to a common channel used to supply cell culture medium and drug treatment [for more details on fabrication, MCTS formation, and cell staining protocols see <xref ref-type="sec" rid="s10">Supplementary Material</xref> and (<xref ref-type="bibr" rid="B5">Chen et&#x20;al., 2021</xref>; <xref ref-type="bibr" rid="B43">Prince et&#x20;al., 2021</xref>)]. The cell suspension occupied 100% of the microwells in the form of cell-laden droplets; MCTSs formed within 72&#xa0;h of cell culture. The viability of breast cancer cells in the MCTSs was evaluated using NucBlue (Hoechst 33342, nuclei) and NucGreen (dead cells), showing &#x223c;89% viability throughout the entire spheroid array (<xref ref-type="fig" rid="F4">Figure&#x20;4B</xref>
<bold>)</bold>. We also confirmed the expression of E-cadherin and F-actin <italic>via</italic> immunostaining to examine proper localization of cell-cell junctions and the presence of actin cytoskeleton, respectively (<xref ref-type="fig" rid="F4">Figure&#x20;4C</xref>). Next, MCTSs were treated with 10-&#xb5;M Doxorubicin (Dox) under two different flow rates, Q, of 0.01 and 0.02&#xa0;ml/h. The results showed that after 2&#xa0;h of drug treatment by perfusion, drug uptake at Q &#x3d; 0.02&#xa0;ml/h was significantly higher than the uptake at Q &#x3d; 0.01&#xa0;ml/h (<xref ref-type="fig" rid="F4">Figure&#x20;4D</xref>). To validate our computational model, we simulated the experimental geometry and flow conditions in&#x20;silico using the same corresponding geometry and conditions <bold>(</bold>
<xref ref-type="fig" rid="F4">Figure&#x20;4E</xref>). As predicted, the fluxes of drug molecules into the MCTSs at Q &#x3d; 0.02&#xa0;ml/h were significantly higher than at Q &#x3d; 0.01&#xa0;ml/h (<xref ref-type="fig" rid="F4">Figure&#x20;4F</xref>
<bold>)</bold>. The increase in flow rate resulted in approximately five-fold increase in the total flux of the drug. Moreover, we compared and analyzed the penetration of drug molecules into the MCTSs using the CFD model (<xref ref-type="sec" rid="s10">Supplementary Material</xref>). The results revealed that the increase in the flow rate of drug treatment significantly enhanced the penetration of the MCTSs with a drug (<xref ref-type="fig" rid="F4">Figure&#x20;4G</xref>
<bold>)</bold>. Thus, the experiments validated our model, thereby enabling us to study changes in drug transport under different conditions and uncover optimal MF device design parameters for a particular application.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Doxorubicin (DOX) uptake by spheroid under two different flow rates (<italic>n &#x3d;</italic> 5). <bold>(A)</bold> A fragment of the 100&#xa0;&#x3bc;m-diameter arrays of MCF-7 breast cancer spheroids after loading. Scale bar is 1&#xa0;mm. <bold>(B)</bold> Brightfield and fluorescence (NucGreen<sup>&#xae;</sup>/NucBlue) images of formed MCF-7 breast cancer spheroids after 72&#xa0;h cell culture. Scale bar is 50&#xa0;&#xb5;m. <bold>(C)</bold> Immunofluorescence staining of tumour spheroids after 72&#xa0;h of cell culture by E-cadherin antibody (green), DAPI (blue) and F-actin (red). Scale bar is 25&#xa0;&#xb5;m. <bold>(D)</bold> Fluorescence images of spheroids after 2&#xa0;h perfusion of 10&#xa0;&#xb5;M DOX under different flow conditions. Scale bar is 100&#xa0;&#xb5;m. <bold>(E)</bold> The defined geometry and porous medium domain in COMSOL Multiphysics. <bold>(F)</bold> Results of drug penetration within the spheroid are visualized as arrows based on the total flux of molecules. <bold>(G)</bold> Results of total flux of DOX evaluated in the midplane of spheroid when Q &#x3d; 0.01&#xa0;ml/h and 0.02&#xa0;ml/h.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g004.tif"/>
</fig>
</sec>
<sec id="s3-3">
<title>Using the Computational Model as a Design Tool</title>
<p>To better understand and compare the effects of device design on drug delivery and biomechanical forces on the spheroids, we used a systematic computational approach that allowed the exploration of &#x3e;15,000 device designs and flow scenarios in a single simulation dataset. Our computational model covered a large parameter space representing a full-factorial experimental design, the results of which can be used during the design stage of the MF device to study the impact of design changes on drug transport. In total our complete dataset includes 10 billion datapoints (&#x223c;15,000 scenarios <inline-formula id="inf18">
<mml:math id="m25">
<mml:mo>&#xd7;</mml:mo>
</mml:math>
</inline-formula> <inline-formula id="inf19">
<mml:math id="m26">
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mo>&#x223c;</mml:mo>
<mml:mn>7</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mn>10</mml:mn>
</mml:mrow>
<mml:mn>5</mml:mn>
</mml:msup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> finite elements per fluid flow and porous medium domain) resulting in &#x223c;95&#xa0;GBs of data. In the following sections, we describe results from the massive dataset, where we simulated the drug transport of Dox, a widely used drug for tumor therapy (<xref ref-type="bibr" rid="B33">Mehta et&#x20;al., 2012</xref>), as our model&#x20;drug.</p>
</sec>
<sec id="s3-4">
<title>Drug Permeation Depends on Spheroid Porosity</title>
<p>Our parametric &#x201c;design screen&#x201d; of &#x3e;15,000 simulations enabled us to systematically investigate the effects of individual parameters on drug uptake <italic>a posteriori</italic>. One physical property of spheroids that plays an important role in drug delivery is the spheroid porosity (<xref ref-type="bibr" rid="B48">Soltani and Chen, 2012</xref>; <xref ref-type="bibr" rid="B49">Soltani et&#x20;al., 2016</xref>). Here, we focused on the effects of spheroid porosity on the velocity field and drug delivery inside the spheroid when the inlet flow rates Q<sub>1</sub> and Q<sub>2</sub> were both 0.01&#xa0;ml/h, and considered advective and diffusive modes of transport separately. We studied the effects of porosity by extracting the simulated results in DSC designs and four different porosities, <inline-formula id="inf20">
<mml:math id="m27">
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.2</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>, 0.5, 0.7, and 0.9, while keeping the geometry, fluid flow, and drug properties the same. We found that changes in porosity increased the total flux of the drug by &#x223c;17&#xd7; when porosity increased from <inline-formula id="inf21">
<mml:math id="m28">
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.2</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>, to <inline-formula id="inf22">
<mml:math id="m29">
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.9</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> (<xref ref-type="fig" rid="F5">Figure&#x20;5C</xref>). However, velocity magnitudes (as viewed on the sagittal <italic>yz</italic> plane) were similar across all porosities. Thus, spheroid porosity clearly influences the drug/nutrient delivery, but has minimal effect on the velocity magnitudes within the spheroid.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Total molecular flux and velocity magnitudes for different spheroid porosities. <bold>(A)</bold> A single unit of the double-supply channel (DSC) design of the spheroid-on-a-chip device, where the defined cross-section represents the sagittal yz-plane. <bold>(B)</bold> 3D contours of velocity magnitude and 3D vectors of drug flux around the spheroid when &#x3c6; &#x3d; 0.9. <bold>(C)</bold> Velocity magnitudes (2D surface plot) and vectors of drug flux within the sagittal yz-plane for &#x3c6; &#x3d; 0.2, 0.5, 0.7, and 0.9.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g005.tif"/>
</fig>
</sec>
<sec id="s3-5">
<title>Drug Permeation Depends on Mode of Transport</title>
<p>Diffusive and advective fluxes are concurrent processes in biological tissues where fluid flow exists, such as the interstitial flow within the stroma. Studying both diffusion and advection transport modes in the spheroid-on-a-chip provides insight into the dynamics of drug uptake while also opening the door to applying our computational models for novel drug design based on transport efficiency (<xref ref-type="bibr" rid="B34">Minchinton and Tannock, 2006</xref>; <xref ref-type="bibr" rid="B9">Dewhirst and Secomb, 2017</xref>). The delivery of adequate concentrations of anticancer drugs to cancer site strongly depends on the structure and drug transport mechanism in tissue. While the effects of structure on tumor response has been studied (<xref ref-type="bibr" rid="B52">Steuperaert et&#x20;al., 2017</xref>; <xref ref-type="bibr" rid="B29">Li et&#x20;al., 2021</xref>), the effect of transport-related factors that play an important role in the delivery of anticancer drugs are much less studied (<xref ref-type="bibr" rid="B9">Dewhirst and Secomb, 2017</xref>). Our model considered both diffusion and advection modes of transport separately, facilitating the evaluation of drug transport mechanisms in our different device designs.</p>
<p>Using our model, we assessed the drug transport modes for Dox under various conditions (see summary of conditions in <xref ref-type="sec" rid="s10">Supplementary Table S1</xref>). First, we arbitrarily selected one device design (W<sub>R</sub> &#x3d; H<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; H<sub>L</sub> &#x3d; 25&#xa0;&#x3bc;m, Q<sub>1</sub> &#x3d; Q<sub>2</sub> &#x3d; 0.01&#xa0;ml/h, <inline-formula id="inf23">
<mml:math id="m30">
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.5</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>, C<sub>dox</sub> &#x3d; 10&#xa0;&#xb5;M) and varied only the chamber radius from 80, 120, and 160&#xa0;&#xb5;m (the complete dataset is summarized in the sections below). When we compared the advection and diffusion transport modes by visualizing 3D volume contours of flux, we found significant differences between the rates of change in diffusion and advection fluxes (<xref ref-type="fig" rid="F6">Figure&#x20;6</xref>
<bold>)</bold>. Closer inspection of the graphs revealed that the transport of drug molecules was diffusion-dominant for smaller microwells (80&#xa0;&#x3bc;m) but advection-dominant for larger microwells (160&#xa0;&#x3bc;m). Note that we refer to a transport mode as &#x201c;dominant&#x201d; if the volume-averaged flux of the dominant mode is (or exceeds) 10x greater than the volume-averaged flux of the other mode. If the flux ratio between modes is less than 10, we consider it a mixed-mode scenario. Our simulations showed that even a single change in one geometric feature (e.g., chamber radius) can substantially affect the drug uptake mechanisms. These results can be further used as a convenient tool to assist pharmacodynamics studies and help identify limiting factors for drug delivery to spheroids cultured on-chip.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>3D volume contours of diffusion and advection fluxes for different microwell sizes of R &#x3d; 80, 120, and 160&#xa0;&#x3bc;m (W<sub>R</sub> &#x3d; H<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; H<sub>L</sub> &#x3d; 25&#xa0;&#xb5;m).</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g006.tif"/>
</fig>
</sec>
<sec id="s3-6">
<title>Drug Delivery Efficiency and Biomechanical Forces</title>
<p>As stated above, adding a second supply microchannel to the device creates vortices inside the microwell and significantly affects the fluid flow around the spheroid. To examine the impact of device geometry and flow patterns on drug transport, we studied drug penetration and uptake by measuring the drug concentration at the center of the spheroid over time using a 3D point probe in COMSOL.</p>
<p>Drug concentration time profiles at the center of the spheroid were plotted for a myriad of different conditions <xref ref-type="fig" rid="F7">(Figure&#x20;7</xref>). We applied two different flow conditions of interest, corresponding to when supply channel flow rates were i) equal (Q<sub>1</sub> &#x3d; Q<sub>2</sub>) (<xref ref-type="fig" rid="F7">Figure&#x20;7A</xref>), and ii) unequal (Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub>) (<xref ref-type="fig" rid="F7">Figure&#x20;7B)</xref>. For each of these flow conditions, the dataset was further divided by varying spheroid porosity <inline-formula id="inf24">
<mml:math id="m31">
<mml:mi>&#x3b5;</mml:mi>
</mml:math>
</inline-formula> (rows) and chamber radius <italic>R</italic> (columns). Finally, for each specific <inline-formula id="inf25">
<mml:math id="m32">
<mml:mi>&#x3b5;</mml:mi>
</mml:math>
</inline-formula> and <italic>R</italic>, we plotted four different groups of curves that allowed us to compare effects of geometry: i) all SSC designs, ii) our &#x201c;reference&#x201d; DSC design where H<sub>R</sub> &#x3d; H<sub>L</sub> &#x3d; W<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m (maximum connecting channel size), iii) varying H<sub>R</sub> and H<sub>L</sub> independently (W<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m), iv) varying W<sub>R</sub> and W<sub>L</sub> independently (H<sub>R</sub> &#x3d; H<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m). The &#x201c;reference&#x201d; DSC design was chosen arbitrarily from the set of simulated designs to allow convenient comparison between different designs.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Concentration vs time profiles simulated at the spheroid core up to <italic>t</italic>&#x20;&#x3d; 120&#xa0;min under different geometric conditions and spheroid porosities (<italic>&#x3c6;</italic>) for <bold>(A)</bold> Q<sub>1</sub> &#x3d; Q<sub>2</sub> and <bold>(B)</bold> Q<sub>1</sub> &#x3d; 2 &#xd7; Q<sub>2</sub>. Legend: &#x201c;SSC Design&#x201d;&#x2014;entire range of SSC designs; &#x201c;Reference DSC Design&#x201d;&#x2014;H<sub>R</sub> &#x3d; H<sub>L</sub> &#x3d; W<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m; &#x201c;Variations in H&#x201d;&#x2014;W<sub>R</sub> &#x3d; W<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m are constant and H varies independently; &#x201c;Variations in W&#x201d;&#x2014;H<sub>R</sub> &#x3d; H<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m are constant and W varies independently.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g007.tif"/>
</fig>
<p>For equal supply channel flow rates (<xref ref-type="fig" rid="F7">Figure&#x20;7A</xref>
<bold>)</bold>, drug delivery was clearly more efficient in all DSC designs compared to the SSC designs, as the drug concentration at the spheroid core was higher for all DSC designs compared to SSC designs in the same amount of time. The reference DSC design was the most efficient, as the spheroid core reached maximum concentration in the shortest amount of time due to the maximum cross-sectional area of the connecting microchannels. Additionally, changing the height of the connector (H<sub>R</sub> and H<sub>L</sub>) showed a larger effect on drug delivery efficiency compared to changes in the width of the connecter (W<sub>R</sub> and W<sub>L</sub>). This effect was more apparent in the simulation with a smaller microwell diameter and less porous spheroids. This can be attributed to the fact that by increasing the size of the microwell, the dominant drug transport mode changes from diffusion to advection (as mentioned above), while by increasing the connector height, more drugs will enter the spheroid at a higher location that is closer to the spheroid&#x20;core.</p>
<p>To explore the effect of flow rate on drug delivery, the same device designs were simulated under the same conditions, but with one supply channel flow rate at twice the flow rate of the other (Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub>). The same trends of drug delivery efficiency were observed (<xref ref-type="fig" rid="F7">Figure&#x20;7B</xref>
<bold>)</bold>. Interestingly, we observed that unequal flow rates in the supply microchannels further improved drug delivery efficiency compared to equal flow rates, as the amount of drug reaching the spheroid core was higher in the same amount of time for unequal flow rates (Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub>) than for equal flow rates (Q<sub>1</sub> &#x3d; Q<sub>2</sub>). For example, when <inline-formula id="inf26">
<mml:math id="m33">
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.6</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> and <italic>R</italic>&#x20;&#x3d; 120&#xa0;&#x3bc;m, drug concentration at the spheroid core reached a plateau at <inline-formula id="inf27">
<mml:math id="m34">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mn>10</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>3</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mtext>mol</mml:mtext>
</mml:mrow>
<mml:mo>/</mml:mo>
<mml:mrow>
<mml:msup>
<mml:mtext>m</mml:mtext>
<mml:mn>3</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> at t &#x3d; 60&#xa0;min when Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub>, but drug concentration did not reach this plateau for Q<sub>1</sub> &#x3d; Q<sub>2</sub>, even after <italic>t</italic>&#x20;&#x3d; 120&#xa0;min. This difference was likely caused by a pressure gradient between two connectors that was generated by the unequal flow rates, ultimately leading to more drugs being actively driven inside the microwell (<xref ref-type="sec" rid="s10">Supplementary Material</xref>).</p>
</sec>
<sec id="s3-7">
<title>Post-Processing and Analysis: Using Design Heatmaps and GUIs as Visualization Tools</title>
<p>Because of the massive dataset generated by our computational design screen, design space exploration became complicated, cumbersome, and time-consuming. To reduce the complexity of the design space and summarize the CFD simulation results in a more convenient fashion, we employed novel classification and clustering methods to sort the various conditions and flow scenarios into groups and reveal underlying patterns in the design parameters <bold>(</bold>
<xref ref-type="fig" rid="F8">Figure&#x20;8</xref>). To evaluate a given device design, we examined the volume-averaged value of five key metrics of flow and transport in the spheroid domain: concentration, velocity, shear rate, advective flux, and diffusive flux. Hierarchically clustered heatmaps were generated for the cases of unequal supply flow rates (Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub>) (<xref ref-type="fig" rid="F8">Figure&#x20;8A</xref>
<bold>)</bold> and equal supply flow rates (Q<sub>1</sub> &#x3d; Q<sub>2</sub>) (<xref ref-type="fig" rid="F8">Figure&#x20;8B</xref>
<bold>)</bold>. These heatmaps summarized the five-key metrics for all 15,000 simulations, enabling us to rapidly and succinctly compare different design effects on the transport of drugs in our principal spheroid-on-a-chip layout.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Hierarchical clustering analysis of MF design space. Hierarchically clustered &#x201c;design heatmaps&#x201d; for <bold>(A)</bold> Q<sub>1</sub> &#x3d; 2&#xd7;Q<sub>2</sub> and <bold>(B)</bold> Q<sub>1</sub> &#x3d; Q<sub>2</sub>, show normalized values of concentration, shear rate, velocity, and advective and diffusive fluxes as five key metrics (columns). Independent device designs (rows) are designated by a naming convention, where P &#x3d; Porosity, R &#x3d; Chamber radius, W<sub>r</sub> &#x3d; Connector width&#x2014;right, H<sub>r</sub> &#x3d; Connector height&#x2014;right, W<sub>l</sub> &#x3d; Connector width&#x2013;left, H<sub>l</sub> &#x3d; Connector height&#x2014;left (e.g., P3. Wr6. R8.Hr6. Wl6. Hl6 denotes <italic>p</italic>&#x20;&#x3d; 0.3, W<sub>r</sub> &#x3d; 60&#xa0;&#x3bc;m, R &#x3d; 80&#xa0;&#x3bc;m, H<sub>r</sub> &#x3d; 60&#xa0;&#x3bc;m, W<sub>L</sub> &#x3d; 60&#xa0;&#x3bc;m, H<sub>L</sub> &#x3d; 60&#xa0;&#xb5;m). Hierarchical clusters were computed with Euclidean distance and farthest point algorithm in Python 3.0 (<xref ref-type="sec" rid="s10">Supplementary Material</xref>). <bold>(C,D)</bold> Illustrative examples of device design selection. Green boxes&#x2013;specific design that achieves both low and high shear by changing flow rate ratio only, with all other metrics constant; Purple boxes&#x2013;specific design that achieves both advection-dominant and diffusion-dominant drug penetration by changing flow rate ratio only, with all other metrics constant.</p>
</caption>
<graphic xlink:href="fbioe-09-781566-g008.tif"/>
</fig>
<p>Hierarchical cluster analysis revealed that for both Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub> and Q<sub>1</sub> &#x3d; Q<sub>2</sub>, shear rate, velocity, and advective flux were grouped together as flow and transport metrics, while both concentration and diffusive flux were differentiated from this primary cluster with only moderate similarities between them. As expected, this clustering predicted that modifications of the device design will affect fluid velocity, shear stress, and advective flux with the same tendency, and that these metrics cannot be varied or controlled separately. On the other hand, the heatmap appeared to show that specific designs can have high concentration and low diffusive flux or vice versa, which illustrates the potential to tune the design based on these two metrics. In terms of clustering of the designs, the heatmap showed that generally, in SSC devices, the drug uptake is mainly diffusion-dominant, and the exerted shear stress and velocity on the spheroids are lower compared to the DSC device design. However, the total amount of drug transport in DSC devices appeared to be higher compared to the SSC device, which is in line with the results in <xref ref-type="fig" rid="F7">Figure&#x20;7</xref>.</p>
<p>Our hierarchically clustered heatmaps improve our understanding of the effects of different parameters on the metrics of flow and transport in the spheroid-on-a-chip layout and facilitate the selection of design parameters prior to any fabrication or experimentation. When designing MF devices, choosing the right range of parameters requires substantial effort and time. Hierarchical clustering helps narrow the design parameter space and empowers the researcher to quickly find the optimal design solution for a given application. To illustrate, we considered a hypothetical experiment that involved studying the effects of shear stress on drug delivery, and asked whether we could select one specific device design from the heatmap that could a) achieve rapid drug penetration (i.e.,&#x20;high drug concentration in the spheroid core in the shortest amount of time), b) permit both high and low applied shear stress on spheroids by changing operating conditions only, and c) keep all other key metrics relatively invariant to create a controlled experiment. Indeed, when we examined the heatmaps in <xref ref-type="fig" rid="F8">Figures 8A,B</xref> closely, we discovered that the design (P9.R8.W<sub>r</sub>6.H<sub>r</sub>6.W<sub>l</sub>6.H<sub>l</sub>2) satisfied all these criteria (<xref ref-type="fig" rid="F8">Figure&#x20;8C)</xref>, since high shear stress can be achieved with Q<sub>1</sub> &#x3d; 2Q<sub>2</sub> (<xref ref-type="fig" rid="F8">Figure&#x20;8A</xref>) while low shear stress can be achieved with Q<sub>1</sub> &#x3d; Q<sub>2</sub>, all in the same geometry. Similarly, as another example, we considered a hypothetical experiment where we examined the effects of advective-dominant vs mixed advective-diffusion transport modes on drug penetration into spheroids. We were able to identify that the design (P9.R8.W<sub>r</sub>.H<sub>r</sub>6.W<sub>l</sub>3.H<sub>l</sub>2) could achieve advective-dominant transport when Q<sub>1</sub> &#x3d; Q<sub>2,</sub> where advection is &#x223c;23&#xd7; greater compared to diffusive flux. To switch to the mixed mode of transport where advective and diffusion fluxes contribute similarly (i.e.,&#x20;diffusive flux is only 2.3&#xd7; greater than the advective flux), the same design can be used with Q<sub>1</sub> &#x3d; 2&#x20;&#xd7; Q<sub>2</sub> (<xref ref-type="fig" rid="F8">Figure&#x20;8D</xref>). Hence, generating hierarchically clustered heatmaps enabled us to summarize and predict drug delivery distribution and efficiency and identify a range of parameters for a particular set of experiments or applications. Thus, our big data &#x201c;design heatmap&#x201d; can ultimately offer a rational approach to the design process that helps us select appropriate designs for proposed experiments in a more time-efficient manner.</p>
<p>Since the primary objective of our computational modelling framework (including our post-processing methods) is to provide the MF engineer with a useful design tool to reduce the design iteration time, guide experiments, and offer operating conditions for end-users of the spheroid-on-a-chip devices, we ventured to create a standalone user-friendly application that can be installed and executed on different devices and operating systems, including Windows, macOS, and Linux (<xref ref-type="sec" rid="s10">Supplementary Material</xref>). This standalone app, which we call &#x201c;SINAI&#x201d; (Spheroid-chip Investigation by Numerical modelling-Application Interface), enables engineers, biologists, and other MF researchers to modify and run the simulations directly&#x2014;even without the need for parallel computing resources&#x2014;and with full control over geometrical, biomaterial, and fluid parameters. The app allows the sharing and dissemination of computational modelling knowledge widely and openly, including to those who do not have a COMSOL Multiphysics license. We envision that this full-factorial computational framework will have the potential to accelerate MF device design for future spheroid-on-a-chip systems, and more broadly for other organ-on-a-chip systems.</p>
<p>We note that every computational model is by its nature a simplification of the entire system; however, in comparison to experiments, our model covered a comprehensive range of flow rates of liquids, microwell and supplying channel dimensions, and MCTS porosity to provide a broad spectrum of possible combinations that may result in desired or undesired effects for MCTS formation and drug delivery. Typically, the process of parametrical sweeping and its range is limited to the computational techniques and capacity. In our <italic>in-silico</italic> model, we utilized parallel computing on a Cloud cluster to improve the performance of this sizeable computational task in a reasonable time. Sweeping and post-processing over the parameter space must be performed for each independent design, which will lead to thousands of design modifications that represent refinements of the principal design. It is conceivable to repeat the process for as many different conceptual designs as needed for the given design problem. Indeed, our approach cannot generate completely novel design concepts automatically: the microfluidics design engineer must continue to play the creative role of generating innovative design concepts that can then be refined extensively using our modelling workflow. In the case described here, we conceptualized SSC and DSC configurations first, and then utilized our modelling and post-processing approach to determine optimized design and operating parameters.</p>
<p>Our work focused on the interplay between both diffusive and advective modes of drug transport and the design of MF devices, taking into account the geometry of the MF device and porosity of MCTSs. The advective component of drug transport plays an essential role in drug delivery <italic>in vivo</italic>, as the molecular transport of drugs with a molecular mass M<sub>r</sub> &#x3e; 1,000 is advection-dominant, as opposed to the transport of low molecular mass drugs with M<sub>r</sub> &#x3c; 1,000, which are diffusive-dominant (<xref ref-type="bibr" rid="B9">Dewhirst and Secomb, 2017</xref>). To examine this effect, we evaluated the dominant drug transport mechanisms in MF devices with various designs. The CFD model facilitated the assessment of the dominant transport mechanisms of drugs in MF devices with different designs.</p>
<p>Our study shows that it is more favourable to use MF devices with a DSC design that enable more rapid delivery of the model drug (DOX) to the MCTSs, compared to the MF device with a single supplying channel. The leading cause of this effect is attributed to the fact that flow in a two-channel MF device creates a pressure gradient in the microwell that results in a more efficient delivery of drug molecules to the MCTSs than in a single-channel MF device. Given the complexity of finding the relationship between various coupled (interdependent) geometrical parameters and non-geometrical conditions, as well as the significance of parametrizing the model by integrating the data into experimental data, we developed hierarchically clustered heatmaps to provide guidance for interpreting data and designing and designing new experiments for spheroid-on-a-chip platforms.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<title>Conclusion</title>
<p>We have described a novel computational framework involving governing physical equations of fluid flow and transport, parametric sweeping, parallel computing, and post-processing and analysis that enables simultaneous simulation of &#x3e;15,000 flow scenarios and designs of a spheroid-on-a-chip MF platform. While the approach is general and can be applied to any MF design, our study focused on one particular spheroid-on-a-chip configuration, which we used as a case study to illustrate the power and efficiency of our approach. The proposed simulation model has the potential to be extended to studies of other types of MF organ-on-a-chip devices. Moreover, the proposed framework will be helpful as a pipeline for more complex CFD modelling and optimization near future.</p>
</sec>
</body>
<back>
<sec id="s5">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s10">Supplementary Material</xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s6">
<title>Author Contributions</title>
<p>SK: Conceptualization, data curation, formal analysis, investigation, methodology, writing&#x2013;original draft, writing&#x2013;review and editing. EK: Conceptualization, funding acquisition, supervision, resources, writing&#x2013;review and editing. EY: Conceptualization, formal analysis, funding acquisition, methodology, project admin, resources, supervision, writing&#x2013;review and editing.</p>
</sec>
<sec id="s7">
<title>Funding</title>
<p>We acknowledge the financial support from the Natural Sciences and Engineering Research Council of Canada (NSERC) Discovery Grant (RGPIN-2019-5885) and a Dean&#x2019;s Catalyst Professorship to EY, and financial support from the NSERC CREATE Training Program in Organ-on-a-Chip Engineering and Entrepreneurship (TOeP, 482073-2016) and an Ontario Graduate Scholarship to SK. We also acknowledge the support from CMC Microsystems for access to their CAD Compute Cluster. EK is grateful to Canada Research Chair (Tier 1) NSERC program.</p>
</sec>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ack>
<p>Some figures were created with BioRender.</p>
</ack>
<sec id="s10">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fbioe.2021.781566/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fbioe.2021.781566/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.docx" id="SM1" mimetype="application/docx" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Afzal</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ansari</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Faizabadi</surname>
<given-names>A. R.</given-names>
</name>
<name>
<surname>Ramis</surname>
<given-names>M. K.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Parallelization Strategies for Computational Fluid Dynamics Software: State of the Art Review</article-title>. <source>Arch. Computat Methods Eng.</source> <volume>24</volume>, <fpage>337</fpage>&#x2013;<lpage>363</lpage>. <pub-id pub-id-type="doi">10.1007/s11831-016-9165-4</pub-id> </citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Amin Arefi</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>Tony Yang</surname>
<given-names>C. W.</given-names>
</name>
<name>
<surname>Sin</surname>
<given-names>D. D.</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>J.&#x20;J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Simulation of Nanoparticle Transport and Adsorption in a Microfluidic Lung-On-A-Chip Device</article-title>. <source>Biomicrofluidics.</source> <volume>14</volume>, <fpage>044117</fpage>. <pub-id pub-id-type="doi">10.1063/5.0011353</pub-id> </citation>
</ref>
<ref id="B3">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Chakraborty</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2010</year>). <source>Microfluidics and Microfabrication</source>. Editor <person-group person-group-type="editor">
<name>
<surname>Chakraborty</surname>
<given-names>S.</given-names>
</name>
</person-group> (<publisher-loc>Boston, MA</publisher-loc>: <publisher-name>Springer US</publisher-name>). <pub-id pub-id-type="doi">10.1007/978-1-4419-1543-6</pub-id> </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chary</surname>
<given-names>S. R.</given-names>
</name>
<name>
<surname>Jain</surname>
<given-names>R. K.</given-names>
</name>
</person-group> (<year>1989</year>). <article-title>Direct Measurement of Interstitial Convection and Diffusion of Albumin in Normal and Neoplastic Tissues by Fluorescence Photobleaching</article-title>. <source>Proc. Natl. Acad. Sci.</source> <volume>86</volume>, <fpage>5385</fpage>&#x2013;<lpage>5389</lpage>. <pub-id pub-id-type="doi">10.1073/PNAS.86.14.5385</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Kheiri</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Gevorkian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
<name>
<surname>Andre</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Deisenroth</surname>
<given-names>T.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Microfluidic Arrays of Dermal Spheroids: a Screening Platform for Active Ingredients of Skincare Products</article-title>. <source>Lab. Chip.</source> <volume>21</volume>, <fpage>3952</fpage>&#x2013;<lpage>3962</lpage>. <pub-id pub-id-type="doi">10.1039/d1lc00619c</pub-id> </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cohen</surname>
<given-names>D. E.</given-names>
</name>
<name>
<surname>Schneider</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chiu</surname>
<given-names>D. T.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Self-digitization of Sample Volumes</article-title>. <source>Anal. Chem.</source> <volume>82</volume>, <fpage>5707</fpage>&#x2013;<lpage>5717</lpage>. <pub-id pub-id-type="doi">10.1021/ac100713u</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Das</surname>
<given-names>A. K.</given-names>
</name>
<name>
<surname>Dewanjee</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2018</year>). &#x201c;<source>Chapter 3 - Optimization of Extraction Using Mathematical Models and Computation</source>
<source>,</source>&#x201d;, eds. <person-group person-group-type="editor">
<name>
<surname>Sarker</surname>
<given-names>S. D.</given-names>
</name>
<name>
<surname>Nahar</surname>
<given-names>L. B. T.-C. P.</given-names>
</name>
</person-group> (<publisher-name>Elsevier</publisher-name>), <fpage>75</fpage>&#x2013;<lpage>106</lpage>. <pub-id pub-id-type="doi">10.1016/B978-0-12-812364-5.00003-1</pub-id> </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>d&#x2019;Esposito</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sweeney</surname>
<given-names>P. W.</given-names>
</name>
<name>
<surname>Ali</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Saleh</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ramasawmy</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Roberts</surname>
<given-names>T. A.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Computational Fluid Dynamics With Imaging of Cleared Tissue and of <italic>In Vivo</italic> Perfusion Predicts Drug Uptake and Treatment Responses in Tumours</article-title>. <source>Nat. Biomed. Eng.</source> <volume>2</volume>, <fpage>773</fpage>&#x2013;<lpage>787</lpage>. <pub-id pub-id-type="doi">10.1038/s41551-018-0306-y</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dewhirst</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Secomb</surname>
<given-names>T. W.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Transport of Drugs From Blood Vessels to Tumour Tissue</article-title>. <source>Nat. Rev. Cancer.</source> <volume>17</volume>, <fpage>738</fpage>&#x2013;<lpage>750</lpage>. <pub-id pub-id-type="doi">10.1038/nrc.2017.93</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Enderling</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Rejniak</surname>
<given-names>K. A.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Simulating Cancer: Computational Models in Oncology</article-title>. <source>Front. Oncol.</source> <volume>3</volume>, <fpage>13</fpage>&#x2013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.3389/fonc.2013.00233</pub-id> </citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fallahi</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Nicholls</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Phan</surname>
<given-names>H.-P.</given-names>
</name>
<name>
<surname>Nguyen</surname>
<given-names>N.-T.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Stretchable Inertial Microfluidic Device for Tunable Particle Separation</article-title>. <source>Anal. Chem.</source> <volume>92</volume>, <fpage>12473</fpage>&#x2013;<lpage>12480</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.0c02294</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gevorkian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Morozova</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>Kheiri</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Khuu</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Actuation of Three-Dimensional-Printed Nanocolloidal Hydrogel With Structural Anisotropy</article-title>. <source>Adv. Funct. Mater.</source> <volume>31</volume>, <fpage>2010743</fpage>. <pub-id pub-id-type="doi">10.1002/adfm.202010743</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hajari</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Baheri Islami</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>A Numerical Study on Tumor-On-Chip Performance and its Optimization for Nanodrug-Based Combination Therapy</article-title>. <source>Biomech. Model. Mechanobiol.</source> <volume>20</volume>, <fpage>983</fpage>&#x2013;<lpage>1002</lpage>. <pub-id pub-id-type="doi">10.1007/s10237-021-01426-8</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Han</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Cao</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Three-Dimensional Analysis and Enhancement of Continuous Magnetic Separation of Particles in Microfluidics</article-title>. <source>Microfluid. Nanofluid.</source> <volume>18</volume>, <fpage>1209</fpage>&#x2013;<lpage>1220</lpage>. <pub-id pub-id-type="doi">10.1007/s10404-014-1516-6</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hohne</surname>
<given-names>D. N.</given-names>
</name>
<name>
<surname>Younger</surname>
<given-names>J.&#x20;G.</given-names>
</name>
<name>
<surname>Solomon</surname>
<given-names>M. J.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Flexible Microfluidic Device for Mechanical Property Characterization of Soft Viscoelastic Solids Such as Bacterial Biofilms</article-title>. <source>Langmuir.</source> <volume>25</volume>, <fpage>7743</fpage>&#x2013;<lpage>7751</lpage>. <pub-id pub-id-type="doi">10.1021/la803413x</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hossain</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Hossainy</surname>
<given-names>S. F. A.</given-names>
</name>
<name>
<surname>Bazilevs</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Calo</surname>
<given-names>V. M.</given-names>
</name>
<name>
<surname>Hughes</surname>
<given-names>T. J.&#x20;R.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Mathematical Modeling of Coupled Drug and Drug-Encapsulated Nanoparticle Transport in Patient-Specific Coronary Artery walls</article-title>. <source>Comput. Mech.</source> <volume>49</volume>, <fpage>213</fpage>&#x2013;<lpage>242</lpage>. <pub-id pub-id-type="doi">10.1007/s00466-011-0633-2</pub-id> </citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>He</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Berk Usta</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Yarmush</surname>
<given-names>M. L.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Generation and Manipulation of Hydrogel Microcapsules by Droplet-Based Microfluidics for Mammalian Cell Culture</article-title>. <source>Lab. Chip.</source> <volume>17</volume>, <fpage>1913</fpage>&#x2013;<lpage>1932</lpage>. <pub-id pub-id-type="doi">10.1039/C7LC00262A</pub-id> </citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huang</surname>
<given-names>T. J.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Introduction to BioMEMS, by Albert Folch . CRC Press, Boca Raton, FL, 2012, 528 Pages. ISBN 978-1-43-981839-8 (Hardcover)</article-title>. <source>Microsc. Microanal.</source> <volume>19</volume>, <fpage>506</fpage>. <pub-id pub-id-type="doi">10.1017/S1431927613000081</pub-id> </citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Humayun</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chow</surname>
<given-names>C.-W.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Microfluidic Lung Airway-On-A-Chip With Arrayable Suspended Gels for Studying Epithelial and Smooth Muscle Cell Interactions</article-title>. <source>Lab. Chip.</source> <volume>18</volume>, <fpage>1298</fpage>&#x2013;<lpage>1309</lpage>. <pub-id pub-id-type="doi">10.1039/C7LC01357D</pub-id> </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hwang</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>Sant</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Masaeli</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kachouie</surname>
<given-names>N. N.</given-names>
</name>
<name>
<surname>Zamanian</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>S.-H.</given-names>
</name>
<etal/>
</person-group> (<year>2010</year>). <article-title>Fabrication of Three-Dimensional Porous Cell-Laden Hydrogel for Tissue Engineering</article-title>. <source>Biofabrication</source> <volume>2</volume>, <fpage>035003</fpage>. <pub-id pub-id-type="doi">10.1088/1758-5082/2/3/035003</pub-id> </citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kaminski</surname>
<given-names>T. S.</given-names>
</name>
<name>
<surname>Garstecki</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Controlled Droplet Microfluidic Systems for Multistep Chemical and Biological Assays</article-title>. <source>Chem. Soc. Rev.</source> <volume>46</volume>, <fpage>6210</fpage>&#x2013;<lpage>6226</lpage>. <pub-id pub-id-type="doi">10.1039/c5cs00717h</pub-id> </citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kheiri</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mohamed</surname>
<given-names>M. G. A.</given-names>
</name>
<name>
<surname>Amereh</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Roberts</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Antibacterial Efficiency Assessment of Polymer-Nanoparticle Composites Using a High-Throughput Microfluidic Platform</article-title>. <source>Mater. Sci. Eng. C.</source> <volume>111</volume>, <fpage>110754</fpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2020.110754</pub-id> </citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Khuu</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Alizadehgiashi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Gevorkian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Galati</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Kumacheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Temperature-Mediated Microfluidic Extrusion of Structurally Anisotropic Hydrogels</article-title>. <source>Adv. Mater. Technol.</source> <volume>4</volume>, <fpage>1800627</fpage>. <pub-id pub-id-type="doi">10.1002/admt.201800627</pub-id> </citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>J.-Y.</given-names>
</name>
<name>
<surname>Fluri</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Marchan</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Boonen</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Mohanty</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Singh</surname>
<given-names>P.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>3D Spherical Microtissues and Microfluidic Technology for Multi-Tissue Experiments and Analysis</article-title>. <source>J.&#x20;Biotechnol.</source> <volume>205</volume>, <fpage>24</fpage>&#x2013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1016/j.jbiotec.2015.01.003</pub-id> </citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>M.-C.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Lam</surname>
<given-names>R. H. W.</given-names>
</name>
<name>
<surname>Thorsen</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Building a Better Cell Trap: Applying Lagrangian Modeling to the Design of Microfluidic Devices for Cell Biology</article-title>. <source>J.&#x20;Appl. Phys.</source> <volume>103</volume>, <fpage>044701</fpage>. <pub-id pub-id-type="doi">10.1063/1.2840059</pub-id> </citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>J.-K.</given-names>
</name>
<name>
<surname>Chung</surname>
<given-names>H. J.</given-names>
</name>
<name>
<surname>Jeon</surname>
<given-names>J.&#x20;S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Microfluidic-Based Observation of Local Bacterial Density Under Antimicrobial Concentration Gradient for Rapid Antibiotic Susceptibility Testing</article-title>. <source>Biomicrofluidics</source> <volume>13</volume>, <fpage>014108</fpage>. <pub-id pub-id-type="doi">10.1063/1.5066558</pub-id> </citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kuzmic</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Moore</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Devadas</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Modelling of Endothelial Cell Migration and Angiogenesis in Microfluidic Cell Culture Systems</article-title>. <source>Biomech. Model. Mechanobiol.</source> <volume>18</volume>, <fpage>717</fpage>&#x2013;<lpage>731</lpage>. <pub-id pub-id-type="doi">10.1007/s10237-018-01111-3</pub-id> </citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Young Yang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Ahn</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2012</year>). <article-title>Gravity-Oriented Microfluidic Device for Uniform and Massive Cell Spheroid Formation</article-title>. <source>Biomicrofluidics</source> <volume>6</volume>, <fpage>014114</fpage>. <pub-id pub-id-type="doi">10.1063/1.3687409</pub-id> </citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Khuu</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Prince</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Tao</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Matrix Stiffness-Regulated Growth of Breast Tumor Spheroids and Their Response to Chemotherapy</article-title>. <source>Biomacromolecules</source> <volume>22</volume>, <fpage>419</fpage>&#x2013;<lpage>429</lpage>. <pub-id pub-id-type="doi">10.1021/acs.biomac.0c01287</pub-id> </citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.-C.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Controllable Organization and High Throughput Production of Recoverable 3D Tumors Using Pneumatic Microfluidics</article-title>. <source>Lab. Chip.</source> <volume>15</volume>, <fpage>1195</fpage>&#x2013;<lpage>1204</lpage>. <pub-id pub-id-type="doi">10.1039/c4lc01242a</pub-id> </citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Xuan</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Continuous Microfluidic Particle Separation via Elasto-Inertial Pinched Flow Fractionation</article-title>. <source>Anal. Chem.</source> <volume>87</volume>, <fpage>6389</fpage>&#x2013;<lpage>6396</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.5b01432</pub-id> </citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McMillan</surname>
<given-names>K. S.</given-names>
</name>
<name>
<surname>Boyd</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Zagnoni</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Transitioning From Multi-phase to Single-phase Microfluidics for Long-Term Culture and Treatment of Multicellular Spheroids</article-title>. <source>Lab. Chip.</source> <volume>16</volume>, <fpage>3548</fpage>&#x2013;<lpage>3557</lpage>. <pub-id pub-id-type="doi">10.1039/c6lc00884d</pub-id> </citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mehta</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Hsiao</surname>
<given-names>A. Y.</given-names>
</name>
<name>
<surname>Ingram</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Luker</surname>
<given-names>G. D.</given-names>
</name>
<name>
<surname>Takayama</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Opportunities and Challenges for Use of Tumor Spheroids as Models to Test Drug Delivery and Efficacy</article-title>. <source>J.&#x20;Controlled Release</source> <volume>164</volume>, <fpage>192</fpage>&#x2013;<lpage>204</lpage>. <pub-id pub-id-type="doi">10.1016/j.jconrel.2012.04.045</pub-id> </citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Minchinton</surname>
<given-names>A. I.</given-names>
</name>
<name>
<surname>Tannock</surname>
<given-names>I. F.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Drug Penetration in Solid Tumours</article-title>. <source>Nat. Rev. Cancer</source> <volume>6</volume>, <fpage>583</fpage>&#x2013;<lpage>592</lpage>. <pub-id pub-id-type="doi">10.1038/nrc1893</pub-id> </citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mohamed</surname>
<given-names>M. G. A.</given-names>
</name>
<name>
<surname>Kheiri</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Islam</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>An Integrated Microfluidic Flow-Focusing Platform for On-Chip Fabrication and Filtration of Cell-Laden Microgels</article-title>. <source>Lab. Chip.</source> <volume>19</volume>, <fpage>1621</fpage>&#x2013;<lpage>1632</lpage>. <pub-id pub-id-type="doi">10.1039/C9LC00073A</pub-id> </citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moore</surname>
<given-names>T. A.</given-names>
</name>
<name>
<surname>Brodersen</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices</article-title>. <source>Anal. Chem.</source> <volume>89</volume>, <fpage>11391</fpage>&#x2013;<lpage>11398</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.7b02351</pub-id> </citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moshksayan</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kashaninejad</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Warkiani</surname>
<given-names>M. E.</given-names>
</name>
<name>
<surname>Lock</surname>
<given-names>J.&#x20;G.</given-names>
</name>
<name>
<surname>Moghadas</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Firoozabadi</surname>
<given-names>B.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Spheroids-on-a-Chip: Recent Advances and Design Considerations in Microfluidic Platforms for Spheroid Formation and Culture</article-title>. <source>Sensors Actuators B: Chem.</source> <volume>263</volume>, <fpage>151</fpage>&#x2013;<lpage>176</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2018.01.223</pub-id> </citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ong</surname>
<given-names>L. J.&#x20;Y.</given-names>
</name>
<name>
<surname>Islam</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>DasGupta</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Iyer</surname>
<given-names>N. G.</given-names>
</name>
<name>
<surname>Leo</surname>
<given-names>H. L.</given-names>
</name>
<name>
<surname>Toh</surname>
<given-names>Y.-C.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>A 3D Printed Microfluidic Perfusion Device for Multicellular Spheroid Cultures</article-title>. <source>Biofabrication</source> <volume>9</volume>, <fpage>045005</fpage>. <pub-id pub-id-type="doi">10.1088/1758-5090/aa8858</pub-id> </citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ota</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Kodama</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Miki</surname>
<given-names>N.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Rapid Formation of Size-Controlled Three Dimensional Hetero-Cell Aggregates Using Micro-Rotation Flow for Spheroid Study</article-title>. <source>Biomicrofluidics</source> <volume>5</volume>, <fpage>034105</fpage>. <pub-id pub-id-type="doi">10.1063/1.3609969</pub-id> </citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ota</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Yamamoto</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Deguchi</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Kazoe</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Sato</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2010</year>). <article-title>Three-Dimensional Spheroid-Forming Lab-On-A-Chip Using Micro-Rotational Flow</article-title>. <source>Sensors Actuators B: Chem.</source> <volume>147</volume>, <fpage>359</fpage>&#x2013;<lpage>365</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2009.11.061</pub-id> </citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pak</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Callander</surname>
<given-names>N. S.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
<name>
<surname>Titz</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Saha</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>MicroC3: an <italic>Ex Vivo</italic> Microfluidic Cis-Coculture Assay to Test Chemosensitivity and Resistance of Patient Multiple Myeloma Cells</article-title>. <source>Integr. Biol.</source> <volume>7</volume>, <fpage>643</fpage>&#x2013;<lpage>654</lpage>. <pub-id pub-id-type="doi">10.1039/C5IB00071H</pub-id> </citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patra</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Peng</surname>
<given-names>C.-C.</given-names>
</name>
<name>
<surname>Liao</surname>
<given-names>W.-H.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>C.-H.</given-names>
</name>
<name>
<surname>Tung</surname>
<given-names>Y.-C.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Drug Testing and Flow Cytometry Analysis on a Large Number of Uniform Sized Tumor Spheroids Using a Microfluidic Device</article-title>. <source>Sci. Rep.</source> <volume>6</volume>, <fpage>1</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1038/srep21061</pub-id> </citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Prince</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Kheiri</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Cruickshank</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Topolskaia</surname>
<given-names>V.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Microfluidic Arrays of Breast Tumor Spheroids for Drug Screening and Personalized Cancer Therapies</article-title>. <source>Adv. Healthc. Mater.</source>, <fpage>2101085</fpage>. <pub-id pub-id-type="doi">10.1002/adhm.202101085</pub-id> </citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rajendra</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Therien-Aubin</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Abolhasani</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Villalabos</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kumacheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>An Exploratory Microfluidic Approach to Photopolymerized Polymer-Inorganic Nanocomposite Films</article-title>. <source>Macromol. Mater. Eng.</source> <volume>300</volume>, <fpage>1071</fpage>&#x2013;<lpage>1078</lpage>. <pub-id pub-id-type="doi">10.1002/mame.201500221</pub-id> </citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rousset</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Monet</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Gervais</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Simulation-assisted Design of Microfluidic Sample Traps for Optimal Trapping and Culture of Non-Adherent Single Cells, Tissues, and Spheroids</article-title>. <source>Sci. Rep.</source> <volume>7</volume>, <fpage>245</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-017-00229-1</pub-id> </citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sabhachandani</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Motwani</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Cohen</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Sarkar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Torchilin</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Konry</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Generation and Functional Assessment of 3D Multicellular Spheroids in Droplet Based Microfluidics Platform</article-title>. <source>Lab. Chip.</source> <volume>16</volume>, <fpage>497</fpage>&#x2013;<lpage>505</lpage>. <pub-id pub-id-type="doi">10.1039/C5LC01139F</pub-id> </citation>
</ref>
<ref id="B47">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schneider</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Yen</surname>
<given-names>G. S.</given-names>
</name>
<name>
<surname>Thompson</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Burnham</surname>
<given-names>D. R.</given-names>
</name>
<name>
<surname>Chiu</surname>
<given-names>D. T.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Self-Digitization of Samples Into a High-Density Microfluidic Bottom-Well Array</article-title>. <source>Anal. Chem.</source> <volume>85</volume>, <fpage>10417</fpage>&#x2013;<lpage>10423</lpage>. <pub-id pub-id-type="doi">10.1021/ac402383n</pub-id> </citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Soltani</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Effect of Tumor Shape and Size on Drug Delivery to Solid Tumors</article-title>. <source>J.&#x20;Biol. Eng.</source> <volume>6</volume>, <fpage>4</fpage>. <pub-id pub-id-type="doi">10.1186/1754-1611-6-4</pub-id> </citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Soltani</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sefidgar</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Bazmara</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Marcus</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Subramaniam</surname>
<given-names>R. M.</given-names>
</name>
<name>
<surname>Rahmim</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Effect of Tumor Size on Drug Delivery to Lung Tumors</article-title>. <source>IEEE Nucl. Sci. Symp. Med. Imaging Conf. Nss/mic.</source> <volume>2015</volume>, <fpage>1</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1109/NSSMIC.2015.7582238</pub-id> </citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sontti</surname>
<given-names>S. G.</given-names>
</name>
<name>
<surname>Atta</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>CFD Analysis of Microfluidic Droplet Formation in Non-Newtonian Liquid</article-title>. <source>Chem. Eng. J.</source> <volume>330</volume>, <fpage>245</fpage>&#x2013;<lpage>261</lpage>. <pub-id pub-id-type="doi">10.1016/j.cej.2017.07.097</pub-id> </citation>
</ref>
<ref id="B51">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sontti</surname>
<given-names>S. G.</given-names>
</name>
<name>
<surname>Atta</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Numerical Insights on Controlled Droplet Formation in a Microfluidic Flow-Focusing Device</article-title>. <source>Ind. Eng. Chem. Res.</source> <volume>59</volume>, <fpage>3702</fpage>&#x2013;<lpage>3716</lpage>. <pub-id pub-id-type="doi">10.1021/acs.iecr.9b02137</pub-id> </citation>
</ref>
<ref id="B52">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Steuperaert</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Falvo D&#x2019;Urso Labate</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Debbaut</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>De Wever</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Vanhove</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Ceelen</surname>
<given-names>W.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Mathematical Modeling of Intraperitoneal Drug Delivery: Simulation of Drug Distribution in a Single Tumor Nodule</article-title>. <source>Drug Deliv.</source> <volume>24</volume>, <fpage>491</fpage>&#x2013;<lpage>501</lpage>. <pub-id pub-id-type="doi">10.1080/10717544.2016.1269848</pub-id> </citation>
</ref>
<ref id="B53">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Suh</surname>
<given-names>Y. K.</given-names>
</name>
<name>
<surname>Kang</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>A Review on Mixing in Microfluidics</article-title>. <source>Micromachines.</source> <volume>1</volume>, <fpage>82</fpage>&#x2013;<lpage>111</lpage>. <pub-id pub-id-type="doi">10.3390/mi1030082</pub-id> </citation>
</ref>
<ref id="B54">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Tian</surname>
<given-names>W. C.</given-names>
</name>
<name>
<surname>Finehout</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2009</year>). <source>Microfluidics for Biological Applications</source>. <publisher-loc>Boston, MA</publisher-loc>: <publisher-name>Springer US</publisher-name>. <pub-id pub-id-type="doi">10.1007/978-0-387-09480-9</pub-id> </citation>
</ref>
<ref id="B55">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Th&#xe9;rien-Aubin</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zandstra</surname>
<given-names>P. W.</given-names>
</name>
<name>
<surname>Kumacheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Two-dimensional Arrays of Cell-Laden Polymer Hydrogel Modules</article-title>. <source>Biomicrofluidics</source> <volume>10</volume>, <fpage>014110</fpage>. <pub-id pub-id-type="doi">10.1063/1.4940430</pub-id> </citation>
</ref>
<ref id="B56">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Westerwalbesloh</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Gr&#xfc;nberger</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Stute</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Weber</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wiechert</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Kohlheyer</surname>
<given-names>D.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Modeling and CFD Simulation of Nutrient Distribution in Picoliter Bioreactors for Bacterial Growth Studies on Single-Cell Level</article-title>. <source>Lab. Chip.</source> <volume>15</volume>, <fpage>4177</fpage>&#x2013;<lpage>4186</lpage>. <pub-id pub-id-type="doi">10.1039/C5LC00646E</pub-id> </citation>
</ref>
<ref id="B57">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Whitesides</surname>
<given-names>G. M.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>The Origins and the Future of Microfluidics</article-title>. <source>Nature</source> <volume>442</volume>, <fpage>368</fpage>&#x2013;<lpage>373</lpage>. <pub-id pub-id-type="doi">10.1038/nature05058</pub-id> </citation>
</ref>
<ref id="B58">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wong</surname>
<given-names>J.&#x20;F.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
<name>
<surname>Simmons</surname>
<given-names>C. A.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Computational Analysis of Integrated Biosensing and Shear Flow in a Microfluidic Vascular Model</article-title>. <source>AIP Adv.</source> <volume>7</volume>, <fpage>115116</fpage>. <pub-id pub-id-type="doi">10.1063/1.5006655</pub-id> </citation>
</ref>
<ref id="B59">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
<name>
<surname>Beebe</surname>
<given-names>D. J.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Fundamentals of Microfluidic Cell Culture in Controlled Microenvironments</article-title>. <source>Chem. Soc. Rev.</source> <volume>39</volume>, <fpage>1036</fpage>. <pub-id pub-id-type="doi">10.1039/b909900j</pub-id> </citation>
</ref>
<ref id="B60">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Young</surname>
<given-names>E. W. K.</given-names>
</name>
<name>
<surname>Pak</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Kahl</surname>
<given-names>B. S.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Callander</surname>
<given-names>N. S.</given-names>
</name>
<name>
<surname>Miyamoto</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2012</year>). <article-title>Microscale Functional Cytomics for Studying Hematologic Cancers</article-title>. <source>Blood</source> <volume>119</volume>, <fpage>e76</fpage>&#x2013;<lpage>e85</lpage>. <pub-id pub-id-type="doi">10.1182/blood-2011-10-384347</pub-id> </citation>
</ref>
<ref id="B61">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Yim</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Cao</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Quantitative Characterization of Micromixing Simulation</article-title>. <source>Biomicrofluidics</source> <volume>2</volume>, <fpage>034104</fpage>. <pub-id pub-id-type="doi">10.1063/1.2966454</pub-id> </citation>
</ref>
<ref id="B62">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zuchowska</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Jastrzebska</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Zukowski</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Chudy</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Dybko</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Brzozka</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>A549 and MRC-5 Cell Aggregation in a MicrofluidicLab-On-A-Chipsystem</article-title>. <source>Biomicrofluidics</source> <volume>11</volume>, <fpage>024110</fpage>. <pub-id pub-id-type="doi">10.1063/1.4979104</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>