A light-activated magnetic bead strategy utilized in spatio-temporal controllable exosomes isolation

www.frontiersin.orgChenhan Wang1 www.frontiersin.orgDuoteng Zhang2 www.frontiersin.orgHaiyan Yang1 www.frontiersin.orgLiang Shi1 www.frontiersin.orgLin Li2 www.frontiersin.orgChangmin Yu2* www.frontiersin.orgJifu Wei3* www.frontiersin.orgQiang Ding1*
  • 1Jiangsu Breast Disease Center, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
  • 2Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing, China
  • 3Department of Pharmacy, Jiangsu Cancer Hospital and Jiangsu Institute of Cancer Research and The Affiliated Cancer Hospital of Nanjing Medical University, Nanjing, China

Tumor-derived exosomes are considered as a key biomarker in the field of liquid biopsy. However, conventional separation techniques such as ultracentrifugation, co-precipitation and column chromatography cannot isolate samples with high throughput, while traditional immunomagnetic separation techniques, due to steric effect of magnetic beads, reducing sensitivity of exosomes optical detection. Herein, we provide a novel and simple nanoplatform for spatiotemporally controlling extraction and elution of exosomes via magnetic separation and light-activated cargo release. In this system, magnetic beads are co-modified by photoresponsive groups -nitrobenzyl group and aptamers that are compatible with CD63-a highly expressed exosomal surface-specific protein. Through exosomes extracted from cell model and nude mice xenograft tumor model morphological characterization and proteomic analysis, results showed that our novel magnetic bead system outperformed current ultracentrifugation in serum exosome extraction in terms of extraction time, yield, and proportion of populations with high CD63 expression. This strategy may be a powerful tool for exosome isolation in clinical liquid biopsies of cancer disease.

Introduction

Liquid biopsy is an emerging adjunctive detection method, which uses biological information carried by body fluid components such as blood, urine, sweat, et al. (Willms et al., 2018; Wang C et al., 2020; Descamps et al., 2022; Markou et al., 2022). Exosomes, a type of small extracellular vesicles with a size of 30–150 nm, are well-documented to participate in tumor development, e.g., stimulating the growth of tumor cells, suppressing anti-tumor immunity, promoting tumor cell migration and metastasis, et al. (Liu et al., 2018; Hofmann et al., 2020; Liao and Li, 2020; Chen et al., 2022; He et al., 2022). They are appealing to liquid biopsy due to following advantages: 1) possessing diverse tumor biological information, such as RNAs, DNAs, and proteins; 2) secreted by and indicating the activity of living tumor cells; 3) easy to preserve and identify via their surface markers (Gurunathan et al., 2019; Sung et al., 2020; Yu et al., 2021). In fact, in some tumors, such as prostate and breast cancer, exosome-based liquid biopsies have shown significant prognostic value (Ibsen et al., 2017; Guo et al., 2020; Shen et al., 2020; Puhka et al., 2022).

Currently, exosomes are mainly isolated through ultracentrifugation (UC) (Momen-Heravi et al., 2013; Wang S et al., 2020; Xie et al., 2020; Yang et al., 2020). UC is normally time- and labor-consuming, and depends on availability of instrument. Some emerging exosome isolation methods, such as size separation-based chromatography column, microfluidic, immunosorbent-based kit etc. (Momen-Heravi et al., 2013; Gurunathan et al., 2019; Shen et al., 2020). These methods are cumbersome in extraction procedures and are not suitable for simple high-throughput detection (Lu et al., 2022; Zhao et al., 2022; Zhu et al., 2022). To solve the issues of centrifugal method, some new separation methods have been developed, such as magnetic bead system based on immunological binding and magnetic separation. Notably, in order to elute the captured exosomes from magnetic beads, non-physiological conditions of extreme ion concentrations are commonly involved, which may cause irreversible damage to exosomes during isolation and subsequently result in false information (Gao et al., 2019; Choi et al., 2022). Moreover, exosome detection methods based on magnetic separation have obvious steric hindrance due to large particle sizes of magnetic beads and exosomes. Detection technologies using fluorescence or chemiluminescence will weaken fluorescence signals due to masking or quenching effect of magnetic beads (Yang et al., 2015). Therefore, the development of a new magnetic bead system for efficient and gentle separation of exosomes has become an urgent need in the field of liquid biopsy.

Light is noninvasive, spatiotemporally controllable, and biocompatible, which is widely used as a trigger in clinical imaging diagnosis and treatment. This inspired us to exploit light-activated degradation to elude exosomes, which would allow spatial, temporal, and rate control by manipulating the location, timing, and intensity of applied light. Herein, we developed a novel strategy using magnetic bead-based capture and light-activated elution for spatiotemporally controllable exosome isolation from serum. As shown in Figure 1, we anchored CD63 aptamer on the surface of magnetic beads via light-sensitive nitrobenzene group, which was cleaved by ultraviolet (UV) light at around 365 nm (Chang et al., 2009; Kobayashi et al., 2012; Lai et al., 2016; Wang et al., 2017; Hentzen et al., 2020). CD63 is member of tetraspanins that is considered to be a reliable exosome surface marker. It plays important roles in membrane transport and has been proved to be a biomarker for breast cancer exosomes (Song et al., 2020; Mathieu et al., 2021). After incubation with serum from breast cancer-bearing mice, our magnetic bead system can selectively bind with the CD63 protein on exosomes, and subsequently isolate the target exosomes with external magnetic field. Finally, the structurally and functionally intact exosomes would be eluted from magnetic beads by regulating light excitation. This nanodevice provides a controllable strategy for separating exosomes from serum, allowing us to maximally preserve the value of exosomes for liquid biopsy and clinical studies. At the same time, the magnetic bead sorting method based on optical control strategy also provides a new platform for exosome detection of liquid homogeneous substances in the future.

FIGURE 1
www.frontiersin.org

FIGURE 1. Schematic illustration of our ultraviolet-responsive nanomagnetic beads for binding and separation of exosomes.

Materials and methods

Materials and reagents

Magnetic beads (CSMN Beads-100, MBs, 100 nm) were purchased from So-Fe Biomedicine (Shanghai, China). The rest of chemical reagents used in the synthesis of nanodevices were purchased from Sinopharm Chemical Reagent Co. (Shanghai, China) and Sigma (Shanghai, China). SUM-1315 cells line was purchased from the Chinese Academy of Sciences (Shanghai, China). DMEM medium (11965092), Penicillin/streptomycin (15140122), and FBS (10099141C) were purchased from GIBCO (Shanghai, China). Anti-CD9 (13,403) primary antibodies were purchased from Cell Signaling Technology (Shanghai, China). Anti-CD63 (ab22595) and anti-calnexin (ab134045) primary antibodies were purchased from Abcam (Shanghai, China). Antirabbit HRP secondary antibodies (a0208), Enhanced-chemiluminescence (ECL) kits (P0018FS), and BCA kit (P0012S) were purchased from Beyotime. Biotechnology (Shanghai, China). CD63 aptamer with azide group was synthesized by Sangon (Shanghai, China), with the following sequence: 5′-CAC CCC ACC TCG CTC CCG TGA CAC TAA TGC TA-3′-N3 (Zhang Z et al., 2019).

Synthesis of magnetic bead system (MBs-Apt63)

Magnetic nanoparticle solution (600 μl, 5 mg/ml) was added to a 1.5 ml centrifuge tube. The nanoparticles were precipitated to bottom of the centrifuge tube with magnets, and supernatant was removed. After being washed with water three times, the nanoparticles were redispersed in 3 ml of 2-morpholinoethanesulfonic acid (MES) buffer with ultrasound. 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) (dissolved with MES, 2.5 mg/ml, 2 ml) and N-hydroxy succinimide (NHS) (dissolved with MES, 5 mg/ml, 1 ml) were then added, followed by sonication for 15 s. The centrifuge tube was sealed by sealing film and shaken at 37°C for 45 min. After that, the nanoparticles were deposited to the bottom of the centrifuge tube and washed twice with phosphate buffered saline (PBS) buffer. The nanoparticles were redispersed in 6 ml PBS. Compound 5 (the compound codes mentioned in this paper were shown in Figure 2) in dimethyl sulfoxide (DMSO) (60 μl, 100 mg/ml) was added to the centrifuge tube and mixed by ultrasound. The mixture was oscillated at 37°C for 12 h. After removal of the supernatant, the CD63 aptamer with azide group was added into the nanoparticles’ aqueous solution at a 1:1 M ratio. 1 mol% copper sulfate pentahydrate and 5 mol% sodium ascorbates were added and solution was shaken at room temperature for 8 h to get the final magnetic bead system (MBs-Apt63).

FIGURE 2
www.frontiersin.org

FIGURE 2. Synthesis routes of photo responsive ligands.

Cell culture

SUM-1315 cells tested negative for mycoplasma were cultured in DMEM supplemented with 10% FBS and 1% penicillin−streptomycin. All cells were cultured in an incubator under 5% CO2 at 37°C.

Agarose gel electrophoresis

The aptamer-MBs mixture system was loaded into each well of the agarose gel and separated via electrophoresis. Target oligonucleotides were detected with Gel-Red kits.

Isolation of exosomes by UC from cell supernatant and serum

Exosomes were extracted from the supernatant of SUM-1315 cells or serum in the following steps: centrifugation was performed at 4°C at 2,000 × g for 10 min, and the supernatant was kept and centrifuged at 10,000 × g for another 30 min to further remove the debris. These samples were transferred to UC tubes and centrifuged at 110,000 × g for 75 min, followed by removal of the supernatant. The precipitates were resuspended and diluted with 1×PBS, and filtered through 0.22 µm membrane. The product was centrifugated again at 110,000 × g for 75 min, and the supernatant was discarded. The pellets were resuspended with 1×PBS and stored at −80°C for further use.

Isolation of exosomes by MBs -Apt63

Magnetic beads (0.1 μg) were added to every 500 μl of exosome suspension or serum to capture exosomes. The binding process was carried out on a shaker. After 20 min, the EP tube was put in a tube rack with a permanent magnet placed against the tube bottom. The supernatant was discarded. After 5 min of precipitation, and the pellets were resuspended in PBS and placed under UV light for 20 min. After elution of the exosomes, the bare magnetic beads were removed by permanent magnets after of 5 min’s adsorption time, and the exosome-containing supernatant was retained in 500 μl PBS.

Transmission electron microscope (TEM)

PBS solution (20 µl) containing exosomes was added to a carbon-coated copper grid and adsorbed. After cleaning with PBS, the copper grid was fixed in 1% glutaraldehyde for 2 min. The excess solution was removed by using paper towel to blot the edges of each grid. Then the sample was negatively stained with saturated uranyl acetate solution and incubated at room temperature for 1min. The unevaporated solution is removed with paper towel. The samples were observed under a transmission electron microscope.

Nanoparticle tracking analysis (NTA)

Nanoparticle tracking analysis was performed on ZetaVIEW S/N 17-310 and all NTA measurements were performed using the same setup to ensure consistent results. The exosomes were diluted in PBS to obtain 50 particles in each field of vision for optimal counting.

Dynamic light scattering (DLS)

Dynamic light scattering (DLS) measurements were conducted on a Nano ZS instrument (Malvern, United Kingdom). All samples were resuspended in PBS, and measured with the same instrument setup.

Western blotting

Exosome suspension (10 μl) was loaded into SDS-PAGE and then separated by electrophoresis. Proteins were transferred onto polyvinylidene fluoride membranes and blocked with 5% skim milk. The primary anti-CD63 and anti-CD9 antibodies were used, followed by incubation with HRP-conjugated secondary antibodies. Target proteins were detected with enhanced-ECL kits.

Animal models

BALB/C-nude mice (female, 4 weeks) were purchased from Model Animal Research Center, Nanjing University. The animal experiment was approved by the Ethics Committee of Nanjing Medical University. We confirmed that all animal experiments are complied with National Institutes of Health guide for the care and use of Laboratory animals (NIH Publications No. 8023, revised 1978). The animals were raised at 25°C with 60% humidity. 2 × 106 of sum-1315 cells were inoculated into the back of each nude mouse. 10 days later, blood was collected from the posterior venous cluster of the eyeball. The blood was placed at room temperature for 2 h and centrifuged at 3000 rpm for 10 min at 4°C, and the upper serum was preserved. The serum of nude mice was stored at −80°C.

High sensitivity flow cytometry

Exosomes were incubated with 20 µl fluorescently labeled antibody (CD63) at 37°C for 30 min in dark. Then 1 ml of pre-cooled PBS (4°C) was added, followed by centrifugation at 110,000 g for 70 min. The supernatant was carefully removed and 1 ml of pre-cooled PBS (4°C) was added to resuspend. The solution was then centrifuged at 110,000 g at 4°C for 70 min, and the supernatant was carefully removed, followed by resuspension of pellets in 50 µl of precooled PBS (4°C) for analysis.

Proteomic analysis of exosomes

Exosome suspension was treated with 7 M urea, 2%SDS, and 1× Protease Inhibitor Cocktail. Protein concentration was determined using the BCA protein detection kit, and then the sample was processed with nuclease digestion, reduction/alkylation, acetone precipitation, and lysine-C/trypsin digestion. Desalination was carried out in the monospin column using 0.1% trifluoroacetic acid (TFA) and acetonitrile. After vacuum drying, 0.1%FA was added to redissolve the sample, and a 1–2 μg of sample was analyzed. The separation was performed with Easy-NLC 1000 (Thermo Scientific, United States) using an analytical column (C18, 1.9 μm, 75 μm × 20 cm) at a flow rate of 300 NL/min. Orbitrap Fusion Lumos (Thermo Scientific, United States) was used as a mass spectrometer. Data Dependent Acquisition (DDA) model was used for tandem mass spectrometry. The full-scan resolution was 60,000 (FWHM), the mass-charge ratio range was set to M/Z 350-1800, and the impact energy was set to 30% in HCD fragmentation mode. The original mass spectrometry data were collected and analyzed using the mass informatics platform Proteome Discoverer 2.4 (Thermo Fisher).

Statistics

Origin 2019 and GraphPad Prism 8.0 were used for statistical calculation of all histograms, and one-way anova was used for calculation of mean and variance.

Results

Synthesis of UV-responsive magnetic bead system (MBs-Apt63)

The 2-nitrobenzyl groups were used as photo-cleavable linkers to anchor CD63 aptamers onto MBs. The detailed synthesis route is shown in Figure 2, and the chemical synthesis steps of photoresponsive ligands are described in Supplementary Material S1. The structure of MBs-Apt63 is shown in Figure 1. Firstly, the photo-cleavable linkers were anchored onto the surface of MBs via a moderate amination reaction. To selectively capture exosomes, CD63 aptamers were finally conjugated with the MBs through click reaction. The final UV-responsive magnetic bead system (MBs-Apt63) was characterized for Zeta potential, infrared spectroscopy, and dynamic light scattering (DLS) size (Supplementary Figure S2 and Supplementary Figure S10).

Magnetic beads respond to UV in vitro

We measured the UV responsiveness of the magnetic beads with a concentration at the range of 0–10 μg/ml, while the time of exposure to UV light was between 0 and 30 min. In Figures 3A,B, it was found that within the range of 0–10 μg/ml, the light-responsive groups of magnetic beads were highly sensitive to and effectively cleaved by UV light. The CD63 aptamers were rapidly released from MBs-Apt63 under irradiation, which also showed obvious time dependence. With increased exposure time, the amount of released free aptamers increased, and reached the maximum after 15 min of UV exposure.

FIGURE 3
www.frontiersin.org

FIGURE 3. Response of MBs-Apt63 to UV in vitro and identification of exosomes (A) Agarose gel electrophoresis (molecular weight of free aptamer = 32 bp) of MBs-Apt63 at different concentrations after UV exposure; (B) Agarose gel electrophoresis of MBs-Apt63 (10.0 μg/ml) after exposure to UV for different times (molecular weight of free aptamer = 32 bp). (C) The expression of CD9, CD63 and calnexin determined by western blotting; (D) The particle size of breast cancer cell exosomes characterized by DLS; (E,F) Transmission electron microscopy image of breast cancer exosomes (magnification = 50000× in C and 100000× in D, exosomes are shown in the red dotted circle).

Preparation and validation of exosomes

To test the ability of MBs-Apt63 to capture exosomes, we firstly extracted tumor exosomes from the cultural medium of breast cancer cell line SUM-1315 by UC. Western blotting analysis of exosomes showed the presence of CD9, CD63 (two common surface markers of exosomes) and calnexin (endoplasmic reticulum protein), indicating the successful preparation (Figure 3C). In DLS analysis, the exosomes showed an average size of 56 nm (Figure 3D), in line with characteristic particle size of exosomes (30–150 nm). Finally, we used TEM to observe the morphology of exosomes (Figures 3E,F), which displayed a typical lipid bilayer structure and a size in the range of 50–100 nm.

Capturing exosomes with MBs-Apt63 and elution with UV light

The process of isolating exosomes from cell supernatant or serum is shown in Figure 4A, which involves beads binding and exosome elution. DLS analysis was performed after MBs binding to exosomes and UV-triggered elution, which showed a size of 250 and 190 nm, respectively. (Figures 4B,C). In Figure 4C, the magnetic bead components were not removed in the system after ultraviolet dissociation. This reduced shift in maximum peak particle size from 256 to 190 nm indicated the elution of exosomes from the MBs after UV exposure. To further elaborate the binding and elution processes, TEM was used to observe the MBs-exosome complex before and after UV-triggered cargo release. Typical MBs bound to many exosomes were clearly seen before exposure to UV light (Figure 4D), whereas only purified exosomes could be observed after UV-induced release of exosomes and removal of magnetic beads by permanent magnets (Figure 4E).

FIGURE 4
www.frontiersin.org

FIGURE 4. Capturing exosomes by and elution of exosomes from MBs-Apt63. (A) Schematic diagram for extracting exosomes from serum and cell supernatant with MBs-Apt63; (B) DLS characterization after incubating exosomes with MBs-Apt63; (C) DLS characterization after exposing the MBs-exosome complex to UV light; (D) Transmission electron microscopy image of exosomes bound to MBs-Apt63 (left, 100000×, right, 25000×). Positions of exosomes and MBs-Apt63 are marked in red; (E) Transmission electron microscopy image of exosomes eluted from MBs-Apt63 by UV light.

Application of MBs-Apt63 in the separation of serum exosomes from breast cancer

To evaluating the performance of this novel MBs system in isolating serum exosomes, we established mice models of triple-negative breast cancer using human breast cancer SUM-1315 cells. We collected the serum when the tumor grew to about 800 mm3, and then isolated exosomes with MBs-Apt63 and conventional UC respectively. We firstly analyzed the particle size distribution (Figure 5A) and particle concentration of exosomes (Figure 5B) with NTA. Results showed that the particle size distribution of exosomes isolated by MBs-Apt63 and UC was similarly uniform, both of which were about 100 nm. While the serum concentration of exosomes acquired by UC is lower compared with that by MBs-Apt63 (2.5 × 109/ml versus 4.0 × 109/ml) according to the particle count analysis, indicating higher efficiency of MBs-Apt63 in extracting serum exosomes.

FIGURE 5
www.frontiersin.org

FIGURE 5. Evaluation of MBs-Apt63 in the isolation of serum tumor exosomes. (A) Particle size distributions of exosomes extracted by UC and MBs-Apt63. (B) Average serum exosome concentrations prepared by UC or MBs-Apt63; (C) Expression abundance of CD63 in exosomes isolated by UC and MBs-Apt63. Results were obtained from nanoflow flow test; (D) GO analysis of proteins from exosomes separated by MBs-Apt63 or UC. Top 10 GO components are displayed that are most enriched in exosomes separated by MBs-Apt63 (p < 0.05 as significance).

Next, we used the high sensitivity flow cytometry (HSFC) system to analyze the expression of CD63 on exosomes separated by UC and MBs-Apt63 (Figure 5C). The results showed that the expression abundance of CD63 was 4.9% in exosomes extracted by MBs-Apt63, which is much higher (0.4%) in exosomes separated by UC method. Therefore, the light strategy in MBs-Apt63 system improved the purity of exosomes with high expression of CD63.

In exosome-based liquid biopsies, diagnostic value ultimately comes from biomarkers in exosomes. In this study, proteins in exosomes separated by UC and magnetic beads were both analyzed by liquid mass spectrometry. We conducted a database search and comparison according to Proteome Discoverer 2.4 system. Specific database search parameters are shown in Supplementary Table S2. The relevant quality control information is shown in Supplementary Figure S5. 1044 proteins were identified in the exosomes isolated by UC, while only 677 proteins were detected in the exosomes separated by magnetic beads (Supplementary Table S3). To verify that our optically controlled MBs-Apt63 preserved more exosome-related proteins, we performed GO analysis on high-expression set of exosome proteins extracted by MBs-Apt63 versus UC. The screening criteria for differential proteins between the two groups were:

(1), Inter-group ratio ≥ 4 (2), Unique Peptides ≥ 2.

Among the top 10 GO components that were significantly higher in exosomes extracted by MBs-Apt63, three are related to exosome formation, including rough endoplasmic reticulum, early endosomes, and endocytic vesicles (Figure 5D), indicating a higher expression abundance of exosome-related proteins in CD63 positive exosomes separated by MBs-Apt63.

Discussions

In this study, we developed a facile light-responsive magnetic bead sorting system for extracting exosomes from breast cancer. In our strategy, 2-nitrobenzene is designed as the surface ligand of the magnetic beads, whose UV responsiveness allows for spatiotemporal control of exosome separation with minimum interference with serum composition. From a practical perspective, it requires less time and smaller sample volume, and does not need sophisticated instruments. More importantly, this system can largely improve the efficiency of exosome isolation, maximizing the purity and integrity of the exosomes. At the same time, without the interference of magnetic beads, exosomes in the real liquid environment can greatly improve the efficiency of the labeled enzyme and substrate reaction. In addition, the masking the effect of magnetic beads themselves will be eliminated. Therefore, this method should be able to improve the sensitivity of subsequent detection.

Previous studies have reported considerable progress in the field of liquid biopsy, particularly some nanomaterial-based liquid biopsy techniques (Zhang P et al., 2019; Tian et al., 2019; Huang et al., 2020; Xia et al., 2020; Chen et al., 2021; He et al., 2021). On this basis, some studies have significantly improved the sensitivity of liquid biopsies, while others have looked at reducing the amount of fluid used in this process (Huang et al., 2019; Li et al., 2019; Kim et al., 2020; Jiang et al., 2021). In this study, the operation mode and sample requirements of liquid biopsy were further simplified. Firstly, the extraction method of exosomes by illumination and magnetic separation does not require additional reagents and processing time, which ensures reproducibility of extraction procedures, making our magnetic bead system can be used in large quantities in clinical practice. Secondly, the spatiotemporally controllable extraction method provides a simple exosome release strategy to remove the steric effect based on magnetic bead fixation, so that magnetic bead-based exosome detection can achieve better detection efficiency in the liquid phase reaction system. At the same time, as most research on UV response devices, the wavelength of UV light used in this study is about 254 nm. It has been shown in some studies that there is no relevant evidence to confirm that 254 nm ultraviolet light will cause damage to proteins under certain conditions of time and intensity (O'Brien et al., 2014; Cannon et al., 2014).

Our experimental results basically demonstrate the clinical application prospect of the system. Compared with traditional ultracentrifugation, the number of exosomes extracted from serum by our system increased by 60%. At the same time, the purity of proteins represented by CD63 was increased by 10 times. Through proteomic analysis, we also confirmed that the MBs-Apt63 preserved more protein components from exosomes. It indicated that, compared with traditional exosome extraction methods in the field of liquid biopsy for clinical cancer patients, this system can obtain the information of tumor in patients’ serum in a relatively comprehensive way, thus providing more reference value for implementation of diagnosis and treatment process. In the future, by changing the aptamers, our strategy provides a flexible approach to pathological analysis of breast cancer for personalized medicine, and its large-scale application can also supply a new platform for broadening the application scope of liquid biopsy of cancer. At the same time, this light-activated magnetic bead strategy also establishes the possibility to nondestructively enrich specific functional cell exosomes for cancer disease treatment (Fang et al., 2022).

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding authors.

Ethics statement

The animal study was reviewed and approved by Ethics Committee of Nanjing Medical University.

Author contributions

QD and CY conceived the idea and supervised the research; CW and DZ designed the experiments; CW, DZ, and HY carried out specific experimental operations; CW, DZ, QD, JW, LL, and CY co-wrote the paper; LS provides clinical consulting and data analysis; All authors discussed the results and commented on the manuscript.

Funding

This study was supported by the National Natural Science Foundation of China (81972486).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fbioe.2022.1006374/full#supplementary-material

References

Cannon, J. R., Cammarata, M. B., Robotham, S. A., Cotham, V. C., Shaw, J. B., Fellers, R. T., et al. (2014). Ultraviolet photodissociation for characterization of whole proteins on a chromatographic time scale. Anal. Chem. 86, 2185–2192. doi:10.1021/ac403859a

PubMed Abstract | CrossRef Full Text | Google Scholar

Chang, D. J., Yoon, E. Y., Lee, G. B., Kim, S. O., Kim, W. J., Kim, Y. M., et al. (2009). Design, synthesis and identification of novel colchicine-derived immunosuppressant. Bioorg. Med. Chem. Lett. 19, 4416–4420. doi:10.1016/j.bmcl.2009.05.054

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, W., Li, Z., Cheng, W., Wu, T., Li, J., Li, X., et al. (2021). Surface plasmon resonance biosensor for exosome detection based on reformative tyramine signal amplification activated by molecular aptamer beacon. J. Nanobiotechnology 19, 450. doi:10.1186/s12951-021-01210-x

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, W., Zhang, Y., Di, K., Liu, C., Xia, Y., Ding, S., et al. (2022). A washing-free and easy-to-operate fluorescent biosensor for highly efficient detection of breast cancer-derived exosomes. Front. Bioeng. Biotechnol. 10, 945858. doi:10.3389/fbioe.2022.945858

PubMed Abstract | CrossRef Full Text | Google Scholar

Choi, D. Y., Park, J. N., Paek, S. H., and Choi, S. C. (2022). Detecting early-stage malignant melanoma using a calcium switch-enriched exosome subpopulation containing tumor markers as a sample. Biosens. Bioelectron. X. 198, 113828. doi:10.1016/j.bios.2021.113828

CrossRef Full Text | Google Scholar

Descamps, L., Le Roy, D., and Deman, A. L. (2022). Microfluidic-based technologies for CTC isolation: a review of 10 years of intense efforts towards liquid biopsy. Int. J. Mol. Sci. 23, 1981. doi:10.3390/ijms23041981

PubMed Abstract | CrossRef Full Text | Google Scholar

Fang, Z. W., Zhang, X. Y., Wu, J., and Huang, H. (2022). Exosome based miRNA delivery strategy for disease treatment. Chin. Chem. Lett. 33, 1693–1704. doi:10.1016/j.cclet.2021.11.050

CrossRef Full Text | Google Scholar

Gao, F., Jiao, F., Xia, C., Zhao, Y., Ying, W., Xie, Y., et al. (2019). A novel strategy for facile serum exosome isolation based on specific interactions between phospholipid bilayers and TiO2. Chem. Sci. 10, 1579–1588. doi:10.1039/c8sc04197k

PubMed Abstract | CrossRef Full Text | Google Scholar

Guo, S., Xu, J., Estell, A. P., Ivory, C. F., Du, D., Lin, Y., et al. (2020). Paper-based ITP technology: An application to specific cancer-derived exosome detection and analysis. Biosens. Bioelectron. X. 164, 112292. doi:10.1016/j.bios.2020.112292

PubMed Abstract | CrossRef Full Text | Google Scholar

Gurunathan, S., Kang, M. H., Jeyaraj, M., Qasim, M., and Kim, J. H. (2019). Review of the isolation, characterization, biological function, and multifarious therapeutic approaches of exosomes. Cells 8, 307. doi:10.3390/cells8040307

PubMed Abstract | CrossRef Full Text | Google Scholar

He, L., Huang, R., Xiao, P., Liu, Y., Jin, L., Liu, H., et al. (2021). Current signal amplification strategies in aptamer-based electrochemical biosensor: A review. Chin. Chem. Lett. 32, 1593–1602. doi:10.1016/j.cclet.2020.12.054

CrossRef Full Text | Google Scholar

He, L., Yu, X., Huang, R., Jin, L., Liu, Y., Deng, Y., et al. (2022). A novel specific and ultrasensitive method detecting extracellular vesicles secreted from lung cancer by padlock probe-based exponential rolling circle amplification. Nano Today 22, 101334. doi:10.1016/j.nantod.2021.101334

CrossRef Full Text | Google Scholar

Hentzen, N. B., Mogaki, R., Otake, S., Okuro, K., and Aida, T. (2020). Intracellular photoactivation of caspase-3 by molecular glues for spatiotemporal apoptosis induction. J. Am. Chem. Soc. 142, 8080–8084. doi:10.1021/jacs.0c01823

PubMed Abstract | CrossRef Full Text | Google Scholar

Hofmann, L., Ludwig, S., Vahl, J. M., Brunner, C., Hoffmann, T. K., and Theodoraki, M. N. (2020). The emerging role of exosomes in diagnosis, prognosis, and therapy in head and neck cancer. Int. J. Mol. Sci. 21, 4072. doi:10.3390/ijms21114072

CrossRef Full Text | Google Scholar

Huang, R., He, L., Xia, Y., Xu, H., Liu, C., Xie, H., et al. (2019). A sensitive aptasensor based on a Hemin/G-Quadruplex-assisted signal amplification strategy for electrochemical detection of gastric cancer exosomes. Small 15, e1900735. doi:10.1002/smll.201900735

PubMed Abstract | CrossRef Full Text | Google Scholar

Huang, R., He, L., Li, S., Liu, H., Jin, L., Chen, Z., et al. (2020). A simple fluorescence aptasensor for gastric cancer exosome detection based on branched rolling circle amplification. Nanoscale 12, 2445–2451. doi:10.1039/c9nr08747h

PubMed Abstract | CrossRef Full Text | Google Scholar

Ibsen, S. D., Wright, J., Lewis, J. M., Kim, S., Ko, S. Y., Ong, J., et al. (2017). Rapid isolation and detection of exosomes and associated biomarkers from plasma. ACS Nano 11, 6641–6651. doi:10.1021/acsnano.7b00549

PubMed Abstract | CrossRef Full Text | Google Scholar

Jiang, K. M., Wu, Y. A., Li, Z. H., Chen, J., Shi, M., and Meng, H. (2021). Molecular recognition triggered aptamer cascade for ultrasensitive detection of exosomes in clinical serum samples. Chin. Chem. Lett. 32, 1827–1830. doi:10.1016/j.cclet.2020.11.031

CrossRef Full Text | Google Scholar

Kim, Y. B., Yang, J. S., Lee, G. B., and Moon, M. H. (2020). Evaluation of exosome separation from human serum by frit-inlet asymmetrical flow field-flow fractionation and multiangle light scattering. Anal. Chim. Acta X. 1124, 137–145. doi:10.1016/j.aca.2020.05.031

PubMed Abstract | CrossRef Full Text | Google Scholar

Kobayashi, T., Komatsu, T., Kamiya, M., Campos, C., Gonzalez-Gaitan, M., Terai, T., et al. (2012). Highly activatable and environment-insensitive optical highlighters for selective spatiotemporal imaging of target proteins. J. Am. Chem. Soc. 134, 11153–11160. doi:10.1021/ja212125w

PubMed Abstract | CrossRef Full Text | Google Scholar

Lai, J., Yu, A., Yang, L., Zhang, Y., Shah, B. P., and Lee, K. B. (2016). Development of photoactivated fluorescent N-hydroxyoxindoles and their application for cell-selective imaging. Chem. Eur. J. 22, 6361–6367. doi:10.1002/chem.201600547

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, Z., Hu, C., Jia, J., Xia, Y., Xie, H., Shen, M., et al. (2019). Establishment and evaluation of a simple size-selective method for exosome enrichment and purification. J. Biomed. Nanotechnol. 15, 1090–1096. doi:10.1166/jbn.2019.2768

PubMed Abstract | CrossRef Full Text | Google Scholar

Liao, H., and Li, H. (2020). Advances in the detection technologies and clinical applications of circulating tumor DNA in metastatic breast cancer. Cancer Manag. Res. 12, 3547–3560. doi:10.2147/cmar.s249041

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, C., Xu, X., Li, B., Situ, B., Pan, W., Hu, Y., et al. (2018). Single-exosome-counting immunoassays for cancer diagnostics. Nano Lett. 18, 4226–4232. doi:10.1021/acs.nanolett.8b01184

PubMed Abstract | CrossRef Full Text | Google Scholar

Lu, Y. X., Tong, Z. D., Mao, H. J., Jian, X., Zhou, L., Qiu, S., et al. (2022). Multiple exosome RNA analysis methods for lung cancer diagnosis through integrated on-chip microfluidic system. Chin. Chem. Lett. 33, 3188–3192. doi:10.1016/j.cclet.2021.12.045

CrossRef Full Text | Google Scholar

Markou, A., Tzanikou, E., and Lianidou, E. (2022). The potential of liquid biopsy in the management of cancer patients. Semin. Cancer Biol. 22, 00069–00079. doi:10.1016/j.semcancer.2022.03.013

CrossRef Full Text | Google Scholar

Mathieu, M., Névo, N., Jouve, M., Valenzuela, J. I., Maurin, M., Verweij, F. J., et al. (2021). Specificities of exosome versus small ectosome secretion revealed by live intracellular tracking of CD63 and CD9. Nat. Commun. 12, 4389–4407. doi:10.1038/s41467-021-24384-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Momen-Heravi, F., Balaj, L., Alian, S., Mantel, P. Y., Halleck, A. E., Trachtenberg, A. J., et al. (2013). Current methods for the isolation of extracellular vesicles. Biol. Chem. 394, 1253–1262. doi:10.1515/hsz-2013-0141

PubMed Abstract | CrossRef Full Text | Google Scholar

O'Brien, J. P., Li, W., Zhang, Y., and Brodbelt, J. S. (2014). Characterization of native protein complexes using ultraviolet photodissociation mass spectrometry. J. Am. Chem. Soc. 37, 12920–12928. doi:10.1021/ja505217w

PubMed Abstract | CrossRef Full Text | Google Scholar

Puhka, M., Thierens, L., Nicorici, D., Forsman, T., Mirtti, T., af Hallstrom, T., et al. (2022). Exploration of extracellular vesicle miRNAs, targeted mRNAs and pathways in prostate cancer: Relation to disease status and progression. Cancers (Basel). 14, 532. doi:10.3390/cancers14030532

PubMed Abstract | CrossRef Full Text | Google Scholar

Shen, M., Di, K., He, H., Xia, Y., Xie, H., Huang, R., et al. (2020). Progress in exosome associated tumor markers and their detection methods. Mol. Biomed. 1, 3. doi:10.1186/s43556-020-00002-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Song, Z., Mao, J., Barrero, R. A., Wang, P., Zhang, F., and Wang, T. (2020). Development of a CD63 aptamer for efficient cancer immunochemistry and immunoaffinity-based exosome isolation. Molecules 25, 5585–5601. doi:10.3390/molecules25235585

PubMed Abstract | CrossRef Full Text | Google Scholar

Sung, B. H., von Lersner, A., Guerrero, J., Krystofiak, E. S., Inman, D., Pelletier, R., et al. (2020). A live cell reporter of exosome secretion and uptake reveals pathfinding behavior of migrating cells. Nat. Commun. 11, 2092. doi:10.1038/s41467-020-15747-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Tian, X., Shen, H., Li, Z., Wang, T., and Wang, S. (2019). Tumor-derived exosomes, myeloid-derived suppressor cells, and tumor microenvironment. J. Hematol. Oncol. 12, 84. doi:10.1186/s13045-019-0772-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, L., Chen, B., Peng, P., Hu, W., Liu, Z., Pei, X., et al. (2017). Fluorescence imaging mitochondrial copper(II) via photocontrollable fluorogenic probe in live cells. Chin. Chem. Lett. 28, 1965–1968. doi:10.1016/j.cclet.2017.07.016

CrossRef Full Text | Google Scholar

Wang, C., Senapati, S., and Chang, H. C. (2020). Liquid biopsy technologies based on membrane microfluidics: High-yield purification and selective quantification of biomarkers in nanocarriers. Electrophoresis 41, 1878–1892. doi:10.1002/elps.202000015

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, S., Khan, A., Huang, R., Ye, S., Di, K., Xiong, T., et al. (2020). Recent advances in single extracellular vesicle detection methods. Biosens. Bioelectron. X. 154, 112056. doi:10.1016/j.bios.2020.112056

PubMed Abstract | CrossRef Full Text | Google Scholar

Willms, E., Cabanas, C., Mager, I., Wood, M. J. A., and Vader, P. (2018). Extracellular vesicle heterogeneity: Subpopulations, isolation techniques, and diverse functions in cancer progression. Front. Immunol. 9, 738. doi:10.3389/fimmu.2018.00738

PubMed Abstract | CrossRef Full Text | Google Scholar

Xia, Y., Hu, X., Di, K., Liu, C., Tan, T., Lin, Y., et al. (2020). Combined detection of exosome concentration and tumor markers in gastric cancer. J. Biomed. Nanotechnol. 16, 252–258. doi:10.1166/jbn.2020.2887

PubMed Abstract | CrossRef Full Text | Google Scholar

Xie, H., Di, K., Huang, R., Khan, A., Xia, Y., Xu, H., et al. (2020). Extracellular vesicles based electrochemical biosensors for detection of cancer cells: A review. Chin. Chem. Lett. 31, 1737–1745. doi:10.1016/j.cclet.2020.02.049

CrossRef Full Text | Google Scholar

Yang, H., Liang, W., He, N., Deng, Y., and Li, Z. (2015). Chemiluminescent labels released from long spacer arm-functionalized magnetic particles: a novel strategy for ultrasensitive and highly selective detection of pathogen infections. ACS Appl. Mat. Interfaces 7, 774–781. doi:10.1021/am507203s

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, Q., Cheng, L., Hu, L., Lou, D., Zhang, T., Li, J., et al. (2020). An integrative microfluidic device for isolation and ultrasensitive detection of lung cancer-specific exosomes from patient urine. Biosens. Bioelectron. X. 163, 112290. doi:10.1016/j.bios.2020.112290

PubMed Abstract | CrossRef Full Text | Google Scholar

Yu, W., Hurley, J., Roberts, D., Chakrabortty, S., Enderle, D., Noerholm, M., et al. (2021). Exosome-based liquid biopsies in cancer: opportunities and challenges. Ann. Oncol. 32, 466–477. doi:10.1016/j.annonc.2021.01.074

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, Z., Tang, C., Zhao, L., Xu, L., Zhou, W., Dong, Z., et al. (2019). Aptamer-based fluorescence polarization assay for separation-free exosome quantification. Nanoscale 11, 10106–10113. doi:10.1039/c9nr01589b

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, P., Zhou, X., He, M., Shang, Y., Tetlow, A. L., Godwin, A. K., et al. (2019). Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip. Nat. Biomed. Eng. 3, 438–451. doi:10.1038/s41551-019-0356-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhao, Y., Fang, X. X., Zhao, Y. X., Zhang, J., Yu, H., Chen, F., et al. (2022). A microfluidic surface-enhanced Raman scattering (SERS) sensor for microRNA in extracellular vesicles with nucleic acid-tyramine cascade amplification. Chin. Chem. Lett. 33, 2101–2104. doi:10.1016/j.cclet.2021.08.047

CrossRef Full Text | Google Scholar

Zhu, F. J., Ji, Y. H., Lu, Y., Li, L., Bai, X., Liu, X., et al. (2022). Microfluidics-based technologies for the analysis of extracellular vesicles at the single-cell level and single-vesicle level. Chin. Chem. Lett. 33, 2893–2900. doi:10.1016/j.cclet.2021.09.058

CrossRef Full Text | Google Scholar

Keywords: exosome, cancer, magnetic separation, light-activated release, liquid biopsy

Citation: Wang C, Zhang D, Yang H, Shi L, Li L, Yu C, Wei J and Ding Q (2022) A light-activated magnetic bead strategy utilized in spatio-temporal controllable exosomes isolation. Front. Bioeng. Biotechnol. 10:1006374. doi: 10.3389/fbioe.2022.1006374

Received: 29 July 2022; Accepted: 15 August 2022;
Published: 06 September 2022.

Edited by:

Zhiyang Li, Nanjing Drum Tower Hospital, China

Reviewed by:

Fernando Soto, Stanford University, United States
Xianguang Ding, Nanjing University of Posts and Telecommunications, China

Copyright © 2022 Wang, Zhang, Yang, Shi, Li, Yu, Wei and Ding. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Qiang Ding, dingqiang@njmu.edu.cn; Changmin Yu, iamcmyu@njtech.edu.cn; Jifu Wei, weijifu@njmu.edu.cn

These authors have contributed equally to this work and share first authorship

Download