AUTHOR=Wang Xuesong, Sun Lin, Liu Meiru, Xia Genglei TITLE=Evaluation of Passive Safety Injection System Performance Under Large Break LOCA for Qinshan PWR JOURNAL=Frontiers in Energy Research VOLUME=9 YEAR=2021 URL=https://www.frontiersin.org/articles/10.3389/fenrg.2021.695773 DOI=10.3389/fenrg.2021.695773 ISSN=2296-598X ABSTRACT=In this work, a brand new passive safety injection system has been designed for the ocean-based Qinshan Phase I nuclear power plant to update and replace the traditional active ones. The passive safety injection system is made up of high pressure, medium pressure, lower pressure safety injection system, and a two-stage automatic depressurization system. To evaluate the safety injection system performance, double-ended cold leg large break LOCA has been analyzed by best-estimated safety analysis RELAP5 code. The main operation and safety parameters such as primary system pressure, safe injection mass flow rates, core water level, and peak cladding temperature have been presented. The results conclude that the safety injection system can act as similar to that of the AP1000, which can assure sufficient core cooling and keep the reactor covered by the cold water under the most severe LBLOCA condition.