<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2022.1029350</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Prediction of excessively low vault after implantable collamer lens implantation using iris morphology</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Khan</surname> <given-names>Muhammad Ahmad</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Tan</surname> <given-names>Qian</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Sun</surname> <given-names>Wei</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Cai</surname> <given-names>Wang</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Zhao</surname> <given-names>Libei</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Lin</surname> <given-names>Ding</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c002"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1978514/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Aier School of Ophthalmology, Central South University</institution>, <addr-line>Changsha</addr-line>, <country>China</country></aff>
<aff id="aff2"><sup>2</sup><institution>Department of Ophthalmology, Changsha Aier Eye Hospital</institution>, <addr-line>Changsha</addr-line>, <country>China</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Kazutaka Kamiya, Kitasato University, Japan</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Lan Ding, Fudan University, China; Carlos Lisa, Fern&#x000E1;ndez-Vega Ophthalmological Institute, Spain</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Ding Lin <email>linding&#x00040;csu.edu.cn</email></corresp>
<corresp id="c002">Libei Zhao <email>libby_zhao&#x00040;hotmail.com</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Ophthalmology, a section of the journal Frontiers in Medicine</p></fn></author-notes>
<pub-date pub-type="epub">
<day>28</day>
<month>10</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>9</volume>
<elocation-id>1029350</elocation-id>
<history>
<date date-type="received">
<day>27</day>
<month>08</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>10</day>
<month>10</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2022 Khan, Tan, Sun, Cai, Zhao and Lin.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Khan, Tan, Sun, Cai, Zhao and Lin</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec>
<title>Purpose</title>
<p>To identify the iris morphology-related factors for prediction of outcomes of excessively low vault (&#x0003C; 100 &#x003BC;m) after Implantable Collamer Lens V4c (ICL V4c; STAAR Surgical) implantation.</p></sec>
<sec>
<title>Methods</title>
<p>This retrospective case-control study included 81 eyes from 2,080 patients who underwent ICL implantation. Twenty-seven eyes of 27 patients with excessively low vault (&#x0003C; 100 &#x003BC;m) constituted the case group (excessively low vault group). Patients with vault (250 to 750 &#x003BC;m) were selected as the optimal vault group by matching anterior chamber depth, white-to-white distance and ICL size with cases with excessive low vault (&#x0003C; 100 &#x003BC;m) at a proportion of 1:2. The preoperative biometric parameters and postoperative vault were recorded. Multiple linear regression analysis was performed to assess the relationship between the postoperative vault and various variables. Conditional logistic regression analysis was used to estimate the risk factors for excessively low vault.</p></sec>
<sec>
<title>Results</title>
<p>The postoperative vault was associated with preoperative pupil diameter (PD), crystalline lens rise, iris concavity and the ratio of the iris concavity to chord length (<italic>P</italic> &#x0003C; 0.05). The larger iris concavity increased risk of excessively low postoperative vault (&#x0003C; 100 &#x003BC;m) (OR = 81.10; 95%CI = 2.87 to 2296.58; <italic>P</italic> = 0.01).</p></sec>
<sec>
<title>Conclusions</title>
<p>Eyes with obviously concave iris were associated with a higher rate of excessively low vault (&#x0003C; 100 &#x003BC;m). Evaluation of iris morphology may provide significant information for predicting excessive postoperative vault.</p></sec></abstract>
<kwd-group>
<kwd>iris concavity</kwd>
<kwd>vault</kwd>
<kwd>implantable collamer lens</kwd>
<kwd>myopia</kwd>
<kwd>AS-OCT</kwd>
</kwd-group>
<counts>
<fig-count count="2"/>
<table-count count="3"/>
<equation-count count="0"/>
<ref-count count="21"/>
<page-count count="6"/>
<word-count count="4187"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Myopia is a major cause of distance vision impairment, which has emerged as an increasingly prevalent public health problem worldwide (<xref ref-type="bibr" rid="B1">1</xref>). Particularly, myopes with high myopia and extremely high myopia are susceptible to be undercorrected. Despite the widely use of laser corneal refractive surgery to correct myopia, the amount of correction is limited for thin corneas, abnormalities in their corneal morphology manifested in topography, or high ametropia.</p>
<p>The Visual Implantable Collamer Lens (ICL; STAAR Surgical, Nidau, Switzerland), a posterior chamber phakic intraocular lens, is popularly used for the correction of high myopia. It can eliminate the risk of corneal ectasia as compared with laser corneal refractive surgery and provide satisfactory visual outcome (<xref ref-type="bibr" rid="B2">2</xref>). However, the safety of ICL implantation is dependent on accurate ICL size and appropriate vault. Excessively high vault can be associated with pupillary block, angle closure, pigment dispersion and subsequent glaucoma. The Visian V4c ICL with a 0.36 mm central port (KS-Aquaport) allows the physiological flow of aqueous humor, which can prevent pupillary block and decrease the risk of elevated intraocular pressure (<xref ref-type="bibr" rid="B3">3</xref>). On the other hand, excessively low vault is regarded as one risk factor of anterior subcapsular cataract. As reported, the minimum required central vault to avoid the incidence of cataract varied from 150 to 230 &#x003BC;m (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>) and subsequent ICL exchange was performed when insufficient vault was &#x0003C; 100 &#x003BC;m (<xref ref-type="bibr" rid="B6">6</xref>). Although the Visian V4c ICL with a central hole can maintain crystalline lens epithelium cells metabolism which may reduce the incidence of cataract, the consequences of the contact of ICL with the crystalline lens remain to be major concern.</p>
<p>Accurate prediction of the vault remains challenging due to the difficulties in preoperative estimation of a relationship between the anatomical structures of the eye and ICL. Recent studies demonstrated that insufficient vault was related to high protrusion of crystalline lens, wide sulcus-to-sulcus, flat cornea and low myopic ICL power (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B8">8</xref>). Despite the variety of associations put forward, excessively low vault still occurs in actual clinical settings, and sometimes ICL exchange is required to avoid low vault related complications. Previous study found that an anterior-posterior compression caused by the iris leading to lower vault (<xref ref-type="bibr" rid="B9">9</xref>). Considering the ICL was placed behind the iris, the horizontal and vertical compression by the iris may influence the postoperative vault (<xref ref-type="bibr" rid="B10">10</xref>). It remains unclear whether the morphology of the iris was the predictive factor related to the excessively low vault.</p>
<p>With anterior segment optical coherence tomography (AS-OCT), preoperative biometric parameters (such as lens position, iris morphology and anterior chamber width) can be obtained rapidly through noncontact procedures. Therefore, the present study aimed to analyzed the shape of iris that may affect the achieved ICL vault, resulting in an excessively low vault (&#x0003C; 100 &#x003BC;m) after ICL implantation based on AS-OCT as compared with the expected vault, thereby facilitating the determination of appropriate ICL size to reduce the occurrence of excessively low vault and ICL exchange.</p></sec>
<sec sec-type="methods" id="s2">
<title>Methods</title>
<sec>
<title>Patients</title>
<p>This study was approved by the Ethics Committee of the Changsha Aier Eye Hospital, Aier Eye Hospital Group, China (ID:2020KYYJ004), and all procedures were conducted according to the tenets of the Declaration of Helsinki. All participants were fully informed about the surgical details and provided written informed consent.</p>
<p>This is a retrospective study which includes 81 eyes from 2080 patients implanted Vision ICL V4c implantation to the correction of myopia at Changsha Aier Eye Hospital from January 2020 to February 2022. Patients were followed up on 1 day, 1 week, 1, 3, 6, and 12 months after surgery. To probe into factors exerting significant influence on excessively low vault, a case-control study was performed. Twenty-seven eyes of 27 patients with vault of &#x0003C; 100 &#x003BC;m on postoperative 1 month constituted the case group (excessively low vault group). And patients with vault of between 250 and 750 &#x003BC;m on postoperative 1 month were selected using a systematic sampling method by matching anterior chamber depth (ACD, &#x000B1;0.2 mm), horizontal white-to-white distance (WTW, &#x000B1;0.1 mm) and ICL size with cases with excessively low vault (&#x0003C; 100 &#x003BC;m) at a proportion of 1:2.</p>
<p>The inclusion criteria of this study were: (1) age ranging from 21 to 45 years; (2) spectacle spherical power between &#x02212;0.50 and &#x02212;18.00 diopters (D); cylindrical power lower than &#x02212;5.00 D; (3) ACD &#x02265;2.8 mm and corneal endothelial cell density &#x0003E;2,000 cells/mm<sup>2</sup>; (4) the implanted ICL sizing was determined strictly according to the manufacturer&#x00027;s recommendations. The exclusion criteria were as follows: preexisting ocular pathology, previous ocular surgery and chronic systemic diseases.</p>
</sec>
<sec>
<title>Preoperative and postoperative examinations</title>
<p>Preoperative ocular examinations, including manifest refraction, non-contact tonometry, slit-lamp microscopy, examination of the fundus, and endothelial cell density measurement were conducted to all participants. WTW, central corneal thickness (CCT), pupil diameter (PD) and keratometry were measured using a Scheimpflug camera (Pentacam HR; Oculus Optikgerate GmbH).</p>
<p>Anterior segment imaging was performed using swept-source anterior segment optical coherence tomography (AS-OCT, CASIA2, Tomey corporation, Nagoya, Japan), as described previously (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B12">12</xref>). The AS-OCT parameters were measured by horizontal scan across the pupil center, including ACD, anterior chamber width (ACW), crystalline lens rise (CLR), iris concavity (IC), iris concavity ratio (ICR), iris thickness at 750 &#x003BC;m from the scleral spur (IT750) and postoperative vault. The ACD was measured from the corneal endothelium at the corneal apex to the crystalline lens anterior surface. ACW was defined as the distance between the scleral spurs on the temporal and nasal and sides. As shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, CLR was the perpendicular distance between the lens anterior surface and a horizontal line joining the two scleral spurs. IC was defined as the maximum distance between the iris posterior surface and the chord from the iris root to the most peripheral point of contact between the iris and lens. ICR was defined as the ratio of the iris concavity to chord length. The ICL vault was measured by AS-OCT on postoperative 1 day, 1 week, and 1, 3, 6, and 12 months.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Anterior segment optical coherence tomography image showing the measurement of the crystalline lens rise (CLR), iris concavity (IC), the ratio of the iris concavity to chord length (ICR), iris thickness at 750 &#x003BC;m from the scleral spur (IT750) and scleral spur (SS).</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-09-1029350-g0001.tif"/>
</fig>
</sec>
<sec>
<title>Statistical analysis</title>
<p>Statistical analyses were performed with SPSS Statistics (version 25, IBM Corp., NY, USA). The normal distribution of the data was tested using the Shapiro&#x02013;Wilk test. Independent sample <italic>t</italic>-test was applied to compared normally distributed continuous variables. Mann-Whitney <italic>U</italic>-test was used to analyze skewed continuous variables. Chi-square test was used to compare categorical variables. Multiple linear regression analysis was performed to assess the relationship between the postoperative vault and various variables. Conditional logistic regression analysis was subsequently used to estimate independent risk factors for the presence of postoperative vault less than 100 &#x003BC;m. A <italic>P</italic> &#x0003C; 0.05 indicated a statistically significant difference.</p></sec>
</sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<p>The demographic and ocular biometric characteristics for different vault groups are summarized in <xref ref-type="table" rid="T1">Table 1</xref>. Comparison AS-OCT images of exhibiting iris concavity with postoperative vault in different groups are presented in <xref ref-type="fig" rid="F2">Figure 2</xref>. The excessively low vault group includes eyes with a vault of &#x0003C; 100 &#x003BC;m (27 eyes), whereas the normal vault group includes eyes with a vault between 250 and 750 &#x003BC;m (54 eyes). The mean postoperative vault was 78.85 &#x000B1; 23.61 &#x003BC;m and 539.63 &#x000B1; 120.82 &#x003BC;m, respectively, in the excessively low vault group and normal vault group. There were no significant differences between the two groups except for CLR, IC and ICR. Eyes in the excessively low vault group had a greater CLR compared with the normal vault group (<italic>P</italic> &#x0003C; 0.001). Among parameters related to the iris morphology measured by AS-OCT, eyes in the excessively low vault group had larger IC and ICR compared to the eyes in the normal vault group (<italic>P</italic> &#x0003C; 0.001).</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Comparisons of demographics and ocular biometric parameters of patients between the excessively low vault and normal vault groups.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Parameter</bold></th>
<th valign="top" align="center"><bold>Excessively low</bold></th>
<th valign="top" align="center"><bold>Normal vault</bold></th>
<th valign="top" align="center"><bold><italic>P</italic></bold></th>
</tr>
<tr>
<th/>
<th valign="top" align="center"><bold>vault (<italic>n</italic> = 27)</bold></th>
<th valign="top" align="center"><bold>(<italic>n</italic> = 54)</bold></th>
<th/>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Age (years)</td>
<td valign="top" align="center">28.93 &#x000B1; 5.76</td>
<td valign="top" align="center">28.93 &#x000B1; 5.05</td>
<td valign="top" align="center">0.93<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">Gender (M/F)</td>
<td valign="top" align="center">8/19</td>
<td valign="top" align="center">15/39</td>
<td valign="top" align="center">0.86<xref ref-type="table-fn" rid="TN2"><sup>b</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">SE (D)</td>
<td valign="top" align="center">&#x02212;8.33 &#x000B1; 2.64</td>
<td valign="top" align="center">&#x02212;7.97 &#x000B1; 2.15</td>
<td valign="top" align="center">0.35<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">ACD (mm)</td>
<td valign="top" align="center">3.12 &#x000B1; 0.10</td>
<td valign="top" align="center">3.15 &#x000B1; 0.10</td>
<td valign="top" align="center">0.07<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">IOP (mmHg)</td>
<td valign="top" align="center">14.87 &#x000B1; 2.10</td>
<td valign="top" align="center">15.17 &#x000B1; 1.92</td>
<td valign="top" align="center">0.53<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">WTW (mm)</td>
<td valign="top" align="center">11.29 &#x000B1; 0.33</td>
<td valign="top" align="center">11.29 &#x000B1; 0.31</td>
<td valign="top" align="center">0.92<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">ACW (mm)</td>
<td valign="top" align="center">11.61 &#x000B1; 0.34</td>
<td valign="top" align="center">11.43 &#x000B1; 0.34</td>
<td valign="top" align="center">0.34<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">CCT (mm)</td>
<td valign="top" align="center">0.51 &#x000B1; 0.03</td>
<td valign="top" align="center">0.51 &#x000B1; 0.03</td>
<td valign="top" align="center">0.44<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">Kf (D)</td>
<td valign="top" align="center">43.05 &#x000B1; 1.34</td>
<td valign="top" align="center">42.55 &#x000B1; 0.87</td>
<td valign="top" align="center">0.09<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">Ks (D)</td>
<td valign="top" align="center">44.30 &#x000B1; 1.58</td>
<td valign="top" align="center">43.63 &#x000B1; 1.09</td>
<td valign="top" align="center">0.06<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">PD (mm)</td>
<td valign="top" align="center">5.65 &#x000B1; 1.04</td>
<td valign="top" align="center">5.72 &#x000B1; 0.86</td>
<td valign="top" align="center">0.75<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">CLR (mm)</td>
<td valign="top" align="center">&#x02212;0.05 &#x000B1; 0.17</td>
<td valign="top" align="center">&#x02212;0.27 &#x000B1; 0.09</td>
<td valign="top" align="center">&#x0003C; 0.001<sup><xref ref-type="table-fn" rid="TN1">a</xref>, <xref ref-type="table-fn" rid="TN4">d</xref></sup></td>
</tr>
<tr>
<td valign="top" align="left">IT750 (mm)</td>
<td valign="top" align="center">0.42 &#x000B1; 0.05</td>
<td valign="top" align="center">0.42 &#x000B1; 0.04</td>
<td valign="top" align="center">0.70<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">IC (mm)</td>
<td valign="top" align="center">0.24 &#x000B1; 0.07</td>
<td valign="top" align="center">0.11 &#x000B1; 0.04</td>
<td valign="top" align="center">&#x0003C; 0.001<sup><xref ref-type="table-fn" rid="TN3">c</xref>, <xref ref-type="table-fn" rid="TN4">d</xref></sup></td>
</tr>
<tr>
<td valign="top" align="left">ICR (mm)</td>
<td valign="top" align="center">0.07 &#x000B1; 0.02</td>
<td valign="top" align="center">0.03 &#x000B1; 0.01</td>
<td valign="top" align="center">&#x0003C; 0.001<sup><xref ref-type="table-fn" rid="TN3">c</xref>, <xref ref-type="table-fn" rid="TN4">d</xref></sup></td>
</tr>
<tr>
<td valign="top" align="left">Postoperative vault (&#x003BC;m)</td>
<td valign="top" align="center">78.85 &#x000B1; 23.61</td>
<td valign="top" align="center">539.63 &#x000B1; 120.82</td>
<td valign="top" align="center">&#x0003C; 0.001<sup><xref ref-type="table-fn" rid="TN3">c</xref>, <xref ref-type="table-fn" rid="TN4">d</xref></sup></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>SE, spherical equivalent; D, diopters; ACD, anterior chamber depth; IOP, intraocular pressure; WTW, horizontal white-to-white diameter; ACW, anterior chamber width; CCT, central corneal thickness; Kf, flat keratometry; Ks, steep keratometry; PD, pupil diameter; CLR, crystalline lens rise; IT750, iris thickness at 750 &#x003BC;m from the scleral spur; IC, iris concavity; ICR, the ratio of the iris concavity to chord length.</p>
<fn id="TN1"><label>a</label><p>Independent t-test.</p></fn>
<fn id="TN2"><label>b</label><p>Chi-square test.</p></fn>
<fn id="TN3"><label>c</label><p>Mann-Whitney U test.</p></fn>
<fn id="TN4"><label>d</label><p><italic>P</italic> &#x0003C; 0.05.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Anterior segment optical coherence tomography images showing flat iris <bold>(A)</bold> with acceptable postoperative vault <bold>(C)</bold> in normal group; and concave iris <bold>(B)</bold> with low vault <bold>(D)</bold> in excessively low vault group.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-09-1029350-g0002.tif"/>
</fig>
<p>The preoperative ocular biometric parameters were strictly selected in the regression model using simple linear regression. One variable was selected in the analysis if the correlation coefficient of the two variables was larger than 0.6. Finally, six parameters were selected in the multiple linear regression analysis (<xref ref-type="table" rid="T2">Table 2</xref>). The results of multiple linear regression analysis showed that the PD, CLR, IC and ICR were the relevant variables related to the vault after ICL implantation (<italic>P</italic> &#x0003C; 0.05).</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Results of multiple linear regression analysis evaluating the correlation between preoperative parameters and postoperative vault (<italic>n</italic> = 81).</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Variable</bold></th>
<th valign="top" align="center"><bold>&#x003B2;</bold></th>
<th valign="top" align="center"><bold><italic>t</italic></bold></th>
<th valign="top" align="center"><bold><italic>P</italic></bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">ACW (mm)</td>
<td valign="top" align="center">0.18</td>
<td valign="top" align="center">1.67</td>
<td valign="top" align="center">0.10</td>
</tr>
<tr>
<td valign="top" align="left">PD (mm)</td>
<td valign="top" align="center">0.26</td>
<td valign="top" align="center">2.80</td>
<td valign="top" align="center">0.007<xref ref-type="table-fn" rid="TN4"><sup>&#x0002A;</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">CLR (mm)</td>
<td valign="top" align="center">&#x02212;0.29</td>
<td valign="top" align="center">&#x02212;3.07</td>
<td valign="top" align="center">0.003<xref ref-type="table-fn" rid="TN4"><sup>&#x0002A;</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">IT750 (mm)</td>
<td valign="top" align="center">&#x02212;0.05</td>
<td valign="top" align="center">&#x02212;0.73</td>
<td valign="top" align="center">0.47</td>
</tr>
<tr>
<td valign="top" align="left">IC (mm)</td>
<td valign="top" align="center">&#x02212;1.10</td>
<td valign="top" align="center">&#x02212;3.09</td>
<td valign="top" align="center">0.003<xref ref-type="table-fn" rid="TN4"><sup>&#x0002A;</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">ICR (mm)</td>
<td valign="top" align="center">0.76</td>
<td valign="top" align="center">2.27</td>
<td valign="top" align="center">0.026<xref ref-type="table-fn" rid="TN4"><sup>&#x0002A;</sup></xref></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>&#x003B2;, unstandardized coefficient; ACW, anterior chamber width; PD, pupil diameter; CLR, crystalline lens rise; IT750, iris thickness at 750 &#x003BC;m from the scleral spur; IC, iris concavity; ICR, the ratio of the iris concavity to chord length.</p>
<fn id="TN5"><label>&#x0002A;</label><p><italic>P</italic> &#x0003C; 0.05.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>Concerning the risk of developing excessively low vault &#x0003C; 100 &#x003BC;m, a multivariable conditional logistic regression model was performed to determine predictive risk factors (<xref ref-type="table" rid="T3">Table 3</xref>). The IC (OR = 81.10; 95%CI = 2.87 to 2296.58; <italic>P</italic> = 0.01) was found to be the only independent risk factors for prediction of excessively low postoperative vault.</p>
<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption><p>Results of conditional logistic regression analysis assessing the risk factors related to excessively low vault (&#x0003C; 100 &#x003BC;m) (<italic>n</italic> = 81).</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Variable</bold></th>
<th valign="top" align="center"><bold>&#x003B2;</bold></th>
<th valign="top" align="center"><bold>SE</bold></th>
<th valign="top" align="center"><bold>OR (95%CI)</bold></th>
<th valign="top" align="center"><bold><italic>P</italic></bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">ACW (mm)</td>
<td valign="top" align="center">0.38</td>
<td valign="top" align="center">0.53</td>
<td valign="top" align="center">1.46 (0.51 to 4.13)</td>
<td valign="top" align="center">0.48</td>
</tr>
<tr>
<td valign="top" align="left">PD (mm)</td>
<td valign="top" align="center">&#x02212;0.18</td>
<td valign="top" align="center">0.52</td>
<td valign="top" align="center">0.84 (0.31 to 2.30)</td>
<td valign="top" align="center">0.73</td>
</tr>
<tr>
<td valign="top" align="left">CLR (mm)</td>
<td valign="top" align="center">&#x02212;0.32</td>
<td valign="top" align="center">0.71</td>
<td valign="top" align="center">0.73 (0.18 to 2.91)</td>
<td valign="top" align="center">0.66</td>
</tr>
<tr>
<td valign="top" align="left">IT750 (mm)</td>
<td valign="top" align="center">&#x02212;0.16</td>
<td valign="top" align="center">0.49</td>
<td valign="top" align="center">0.86 (0.33 to 2.22)</td>
<td valign="top" align="center">0.75</td>
</tr>
<tr>
<td valign="top" align="left">IC (mm)</td>
<td valign="top" align="center">4.40</td>
<td valign="top" align="center">1.71</td>
<td valign="top" align="center">81.10 (2.87 to 2296.58)</td>
<td valign="top" align="center">0.01<xref ref-type="table-fn" rid="TN5"><sup>&#x0002A;</sup></xref></td>
</tr>
<tr>
<td valign="top" align="left">ICR (mm)</td>
<td valign="top" align="center">0.26</td>
<td valign="top" align="center">0.50</td>
<td valign="top" align="center">1.29 (0.49 to 3.44)</td>
<td valign="top" align="center">0.61</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>&#x003B2;, regression coefficient; SE, standard error; OR, odds ratio; CI, confidence interval; ACW, anterior chamber width; PD, pupil diameter; CLR, crystalline lens rise; IT750, iris thickness at 750 &#x003BC;m from the scleral spur; IC, iris concavity; ICR, the ratio of the iris concavity to chord length.</p>
<fn id="TN6"><label>&#x0002A;</label><p><italic>P</italic> &#x0003C; 0.05.</p></fn>
</table-wrap-foot>
</table-wrap></sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>Accurate prediction of the postoperative vault remains challenging for refractive experts. Many studies have attempted to solve the problem by developing ICL sizing formulas and exploring more influencing factors. However, unexpected excessively low vault still occurs occasionally, leading to ICL exchange and cataract formation. It arouses more thinking on whether some existing underlying factors that have been ignored previously. A previous study by Kojima and associates, using high-frequency ultrasound biomicroscopy (UBM), showed that the distance between sulcus-to-sulcus plane and anterior crystalline lens surface (STSL) was defined as a predictor for optimal ICL sizing (<xref ref-type="bibr" rid="B13">13</xref>). UBM is invasive and shows poor reproducibility due to unstable measurement sites. In contrast, AS-OCT is already being widely used to develop ICL sizing formulas and predict postoperative vault, owing to its non-invasiveness and conduciveness to preoperative measurement and postoperative follow-up. Nakamura et al. (<xref ref-type="bibr" rid="B14">14</xref>) developed a novel ICL sizing method based on the AS-OCT, in which CLR proved to be a candidate for predicting the vault after ICL implantation. The influence of crystalline lens position on the postoperative vault has been reported in various studies (<xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B16">16</xref>). As reported, the CLR represented the anterior portion of the lens (<xref ref-type="bibr" rid="B17">17</xref>). In the present study, higher CLR (&#x02212;0.05 &#x000B1; 0.17) were found in the excessively low vault group, whereas the normal vault group tended to have significantly lower mean values (&#x02212;0.27 &#x000B1; 0.09). Regression analysis also disclosed that CLR was associated with postoperative vault. Our findings were in agreement with previous studies that described a forward lens position or high crystalline lens rise could have lower postoperative vault. In addition, our study also showed that the PD was a relevant parameter related to the postoperative vault. Consistently, Gonzalez-Lopez et al. (<xref ref-type="bibr" rid="B18">18</xref>) observed that the changes in the pupil size under different light conditions were associated with the vault after ICL implantation based on dynamic AS-OCT. Myopic eyes with larger pupil size were often predisposed to higher postoperative vault (<xref ref-type="bibr" rid="B19">19</xref>). These findings indicated that the causative factor for the change in pupil size might be considered preoperatively.</p>
<p>AS-OCT parameters including IC and ICR were measured to assess the shape of iris. IC could better quantify the displacement of the iris. Consequently, iris concavity was selected to represent the morphology of the iris in the regression model. The results of regression analysis showed that IC and ICR influenced the postoperative vault. Additionally, the concavity of iris was the only independent risk factors for prediction of excessively low postoperative vault. This finding indicated that the eyes with larger iris concavity were associated with a higher rate of excessively low vault (&#x0003C; 100 &#x003BC;m) after ICL implantation. However, IT750 were not statistically correlated with the postoperative ICL vaulting. As the iris draped over the lens and acted as a reverse force, we speculated that the reverse force of the iris prevented the rise of vault after ICL implantation and concave iris could increase reverse force and finally induce excessively low vault. As known, concave iris configuration was associated with pigment dispersion syndrome due to increased iridolenticular contact (<xref ref-type="bibr" rid="B20">20</xref>). ICL implantation increases iridozonular and iridociliary-process distances, which may minimize iridolenticular contact. A recent study (<xref ref-type="bibr" rid="B21">21</xref>) investigated the influence of the iris and ciliary body morphology on the postoperative vault and indicated that eyes with a thicker lens and larger iris reverse convexity were significant correlation with the insufficient postoperative vault. Meanwhile, in our current study, all ICLs in the excessively low vault group were replaced for a larger lens sizing and obtained optimal postoperative vaults (range from 250 to 750 &#x003BC;m). Based on above conditions, we speculated that underestimation of the ICL size and consequently a risk of insufficient vault might happen when a conventional ICL sizing method was used in eyes with larger iris concavity. Thus, exchanging ICL for the larger size seemed a reasonable solution to avoid the occurrence of excessively low vault in these patients.</p>
<p>The results of this research highlight important aspects for influence on postoperative vault prediction. To the best of our knowledge, this is the first study attempting to evaluate the iris morphology-related factors for prediction of outcomes of excessively low vault (&#x0003C; 100 &#x003BC;m) after ICL implantation. On the basis of our findings, eyes with obviously concave iris were associated with a higher rate of excessively low vault after ICL implantation. Consequently, in addition to the lens position, the concavity of iris should be considered as an important factor in the selection of ICL sizing and the prediction of the postoperative vault.</p>
<p>The primary limitations of this study are the retrospective and observational nature of the study and the relatively small sample size. Furthermore, we only observed the horizontal iris morphology, absence of records of vertical iris morphology might restrain us figuring out their roles in affecting postoperative vault. A large prospective cohort study containing different directions of iris morphology is essential to confirm our findings in the future.</p>
<p>In conclusion, larger iris concavity was a major risk factor in eyes presenting excessively low vault. This finding offers a new insight about the preoperative strategy in ICL size and the prediction of postoperative vault.</p></sec>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding authors.</p></sec>
<sec id="s6">
<title>Ethics statement</title>
<p>Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.</p></sec>
<sec id="s7">
<title>Author contributions</title>
<p>DL and LZ designed and directed the project. MK and LZ carried out the study and drafted the manuscript. QT, WS, and WC participated in collection, management, analysis, and interpretation of data. All authors were involved in review and final approval of the manuscript.</p></sec>
<sec sec-type="funding-information" id="s8">
<title>Funding</title>
<p>This study was supported in part by the research project of the Science Research Foundation of Aier Eye Hospital Group (Grant No. AF2106D3).</p></sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x00027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p></sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Naidoo</surname> <given-names>KS</given-names></name> <name><surname>Fricke</surname> <given-names>TR</given-names></name> <name><surname>Frick</surname> <given-names>KD</given-names></name> <name><surname>Jong</surname> <given-names>M</given-names></name> <name><surname>Naduvilath</surname> <given-names>TJ</given-names></name> <name><surname>Resnikoff</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Potential lost productivity resulting from the global burden of myopia: systematic review, meta-analysis, and modeling</article-title>. <source>Ophthalmology.</source> (<year>2019</year>) <volume>126</volume>:<fpage>338</fpage>&#x02013;<lpage>46</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2018.10.029</pub-id><pub-id pub-id-type="pmid">30342076</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Siedlecki</surname> <given-names>J</given-names></name> <name><surname>Schmelter</surname> <given-names>V</given-names></name> <name><surname>Mayer</surname> <given-names>WJ</given-names></name> <name><surname>Schworm</surname> <given-names>B</given-names></name> <name><surname>Priglinger</surname> <given-names>SG</given-names></name> <name><surname>Dirisamer</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>SMILE versus implantable collamer lens implantation for high myopia: a matched comparative study</article-title>. <source>J Refract Surg.</source> (<year>2020</year>) <volume>36</volume>:<fpage>150</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20200210-02</pub-id><pub-id pub-id-type="pmid">32396649</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gonzalez-Lopez</surname> <given-names>F</given-names></name> <name><surname>Bilbao-Calabuig</surname> <given-names>R</given-names></name> <name><surname>Mompean</surname> <given-names>B</given-names></name> <name><surname>de Rojas</surname> <given-names>V</given-names></name> <name><surname>Luezas</surname> <given-names>J</given-names></name> <name><surname>Djodeyre</surname> <given-names>MR</given-names></name> <etal/></person-group>. <article-title>Intraocular pressure during the early postoperative period after 100 consecutive implantations of posterior chamber phakic intraocular lenses with a central hole</article-title>. <source>J Cataract Refract Surg.</source> (<year>2013</year>) <volume>39</volume>:<fpage>1859</fpage>&#x02013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2013.06.020</pub-id><pub-id pub-id-type="pmid">24427793</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lim</surname> <given-names>DH</given-names></name> <name><surname>Lee</surname> <given-names>MG</given-names></name> <name><surname>Chung</surname> <given-names>ES</given-names></name> <name><surname>Chung</surname> <given-names>TY</given-names></name></person-group>. <article-title>Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth</article-title>. <source>Am J Ophthalmol</source>. (<year>2014</year>) <volume>158</volume>:<fpage>447</fpage>&#x02013;<lpage>54</lpage>.e1. <pub-id pub-id-type="doi">10.1016/j.ajo.2014.06.005</pub-id><pub-id pub-id-type="pmid">24952274</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schmidinger</surname> <given-names>G</given-names></name> <name><surname>Lackner</surname> <given-names>B</given-names></name> <name><surname>Pieh</surname> <given-names>S</given-names></name> <name><surname>Skorpik</surname> <given-names>C</given-names></name></person-group>. <article-title>Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients</article-title>. <source>Ophthalmology.</source> (<year>2010</year>) <volume>117</volume>:<fpage>1506</fpage>&#x02013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2009.12.013</pub-id><pub-id pub-id-type="pmid">20363503</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>QY</given-names></name> <name><surname>Xie</surname> <given-names>XL</given-names></name> <name><surname>Chen</surname> <given-names>Q</given-names></name></person-group>. <article-title>Prevention and management of collagen copolymer phakic intraocular lens exchange: causes and surgical techniques</article-title>. <source>J Cataract Refract Surg.</source> (<year>2015</year>) <volume>41</volume>:<fpage>576</fpage>&#x02013;<lpage>84</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2014.06.036</pub-id><pub-id pub-id-type="pmid">25804582</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tranc&#x000F3;n</surname> <given-names>AS</given-names></name> <name><surname>Manito</surname> <given-names>SC</given-names></name> <name><surname>Sierra</surname> <given-names>OT</given-names></name> <name><surname>Baptista</surname> <given-names>AM</given-names></name> <name><surname>Serra</surname> <given-names>PM</given-names></name></person-group>. <article-title>Determining vault size in implantable collamer lenses: preoperative anatomy and lens parameters</article-title>. <source>J Cataract Refract Surg.</source> (<year>2020</year>) <volume>46</volume>:<fpage>728</fpage>&#x02013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000146</pub-id><pub-id pub-id-type="pmid">32358268</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cerpa Manito</surname> <given-names>S</given-names></name> <name><surname>S&#x000E1;nchez Tranc&#x000F3;n</surname> <given-names>A</given-names></name> <name><surname>Torrado Sierra</surname> <given-names>O</given-names></name> <name><surname>Baptista</surname> <given-names>AM</given-names></name> <name><surname>Serra</surname> <given-names>PM</given-names></name></person-group>. <article-title>Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses</article-title>. <source>Eye Vis.</source> (<year>2021</year>) <volume>8</volume>:<fpage>26</fpage>. <pub-id pub-id-type="doi">10.1186/s40662-021-00250-6</pub-id><pub-id pub-id-type="pmid">34225809</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H</given-names></name> <name><surname>Kang</surname> <given-names>SY</given-names></name> <name><surname>Seo</surname> <given-names>KY</given-names></name> <name><surname>Chung</surname> <given-names>B</given-names></name> <name><surname>Choi</surname> <given-names>JY</given-names></name> <name><surname>Kim</surname> <given-names>KS</given-names></name> <etal/></person-group>. <article-title>Dynamic vaulting changes in V4c versus V4 posterior chamber phakic lenses under differing lighting conditions</article-title>. <source>Am J Ophthalmol</source>. (<year>2014</year>) <volume>158</volume>:<fpage>1199</fpage>&#x02013;<lpage>204</lpage>.e1. <pub-id pub-id-type="doi">10.1016/j.ajo.2014.08.020</pub-id><pub-id pub-id-type="pmid">25149911</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>DH</given-names></name> <name><surname>Choi</surname> <given-names>SH</given-names></name> <name><surname>Chung</surname> <given-names>ES</given-names></name> <name><surname>Chung</surname> <given-names>TY</given-names></name></person-group>. <article-title>Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting</article-title>. <source>Ophthalmology.</source> (<year>2012</year>) <volume>119</volume>:<fpage>272</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2011.07.047</pub-id><pub-id pub-id-type="pmid">22054995</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tan</surname> <given-names>SS</given-names></name> <name><surname>Tun</surname> <given-names>TA</given-names></name> <name><surname>Sultana</surname> <given-names>R</given-names></name> <name><surname>Tan</surname> <given-names>M</given-names></name> <name><surname>Quah</surname> <given-names>JH</given-names></name> <name><surname>Mani</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>Diagnostic accuracy of swept source optical coherence tomography classification algorithms for detection of gonioscopic angle closure</article-title>. <source>Br J Ophthalmol.</source> (<year>2021</year>). <pub-id pub-id-type="doi">10.1136/bjophthalmol-2021-319165.</pub-id> [Epub ahead of print].<pub-id pub-id-type="pmid">34193408</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nakamura</surname> <given-names>T</given-names></name> <name><surname>Isogai</surname> <given-names>N</given-names></name> <name><surname>Kojima</surname> <given-names>T</given-names></name> <name><surname>Yoshida</surname> <given-names>Y</given-names></name> <name><surname>Sugiyama</surname> <given-names>Y</given-names></name></person-group>. <article-title>Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography</article-title>. <source>Am J Ophthalmol.</source> (<year>2018</year>) <volume>187</volume>:<fpage>99</fpage>&#x02013;<lpage>107</lpage>. <pub-id pub-id-type="doi">10.1016/j.ajo.2017.12.015</pub-id><pub-id pub-id-type="pmid">29294311</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kojima</surname> <given-names>T</given-names></name> <name><surname>Yokoyama</surname> <given-names>S</given-names></name> <name><surname>Ito</surname> <given-names>M</given-names></name> <name><surname>Horai</surname> <given-names>R</given-names></name> <name><surname>Hara</surname> <given-names>S</given-names></name> <name><surname>Nakamura</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy</article-title>. <source>Am J Ophthalmol</source>. (<year>2012</year>) <volume>153</volume>:<fpage>632</fpage>&#x02013;<lpage>7</lpage>.e1. <pub-id pub-id-type="doi">10.1016/j.ajo.2011.06.031</pub-id><pub-id pub-id-type="pmid">22245462</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nakamura</surname> <given-names>T</given-names></name> <name><surname>Isogai</surname> <given-names>N</given-names></name> <name><surname>Kojima</surname> <given-names>T</given-names></name> <name><surname>Yoshida</surname> <given-names>Y</given-names></name> <name><surname>Sugiyama</surname> <given-names>Y</given-names></name></person-group>. <article-title>Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography</article-title>. <source>J Cataract Refract Surg.</source> (<year>2020</year>) <volume>46</volume>:<fpage>742</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000134</pub-id><pub-id pub-id-type="pmid">32358270</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gonzalez-Lopez</surname> <given-names>F</given-names></name> <name><surname>Bilbao-Calabuig</surname> <given-names>R</given-names></name> <name><surname>Mompean</surname> <given-names>B</given-names></name> <name><surname>Luezas</surname> <given-names>J</given-names></name> <name><surname>Ortega-Usobiaga</surname> <given-names>J</given-names></name> <name><surname>Druchkiv</surname> <given-names>V</given-names></name></person-group>. <article-title>Determining the potential role of crystalline lens rise in vaulting in posterior chamber phakic collamer lens surgery for correction of myopia</article-title>. <source>J Refract Surg.</source> (<year>2019</year>) <volume>35</volume>:<fpage>177</fpage>&#x02013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20190204-01</pub-id><pub-id pub-id-type="pmid">30855095</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Qi</surname> <given-names>MY</given-names></name> <name><surname>Chen</surname> <given-names>Q</given-names></name> <name><surname>Zeng</surname> <given-names>QY</given-names></name></person-group>. <article-title>The effect of the crystalline lens on central vault after implantable collamer lens implantation</article-title>. <source>J Refract Surg.</source> (<year>2017</year>) <volume>33</volume>:<fpage>519</fpage>&#x02013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20170602-02</pub-id><pub-id pub-id-type="pmid">28787516</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nongpiur</surname> <given-names>ME</given-names></name> <name><surname>He</surname> <given-names>M</given-names></name> <name><surname>Amerasinghe</surname> <given-names>N</given-names></name> <name><surname>Friedman</surname> <given-names>DS</given-names></name> <name><surname>Tay</surname> <given-names>WT</given-names></name> <name><surname>Baskaran</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Lens vault, thickness, and position in Chinese subjects with angle closure</article-title>. <source>Ophthalmology.</source> (<year>2011</year>) <volume>118</volume>:<fpage>474</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2010.07.025</pub-id><pub-id pub-id-type="pmid">21035864</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gonzalez-Lopez</surname> <given-names>F</given-names></name> <name><surname>Bouza-Miguens</surname> <given-names>C</given-names></name> <name><surname>Tejerina</surname> <given-names>V</given-names></name> <name><surname>Druchkiv</surname> <given-names>V</given-names></name> <name><surname>Mompean</surname> <given-names>B</given-names></name> <name><surname>Ortega-Usobiaga</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation</article-title>. <source>Eye Vis.</source> (<year>2021</year>) <volume>8</volume>:<fpage>39</fpage>. <pub-id pub-id-type="doi">10.1186/s40662-021-00262-2</pub-id><pub-id pub-id-type="pmid">34688308</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H</given-names></name> <name><surname>Kang</surname> <given-names>DSY</given-names></name> <name><surname>Choi</surname> <given-names>JY</given-names></name> <name><surname>Ha</surname> <given-names>BJ</given-names></name> <name><surname>Kim</surname> <given-names>EK</given-names></name> <name><surname>Seo</surname> <given-names>KY</given-names></name> <etal/></person-group>. <article-title>Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12</article-title>.6-mm V4c implantable collamer lens in myopic eyes. <source>BMC Ophthalmol.</source> (<year>2018</year>) <volume>18</volume>:<fpage>163</fpage>. <pub-id pub-id-type="doi">10.1186/s12886-018-0835-x</pub-id><pub-id pub-id-type="pmid">29980187</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liebmann</surname> <given-names>JM</given-names></name> <name><surname>Tello</surname> <given-names>C</given-names></name> <name><surname>Chew</surname> <given-names>SJ</given-names></name> <name><surname>Cohen</surname> <given-names>H</given-names></name> <name><surname>Ritch</surname> <given-names>R</given-names></name></person-group>. <article-title>Prevention of blinking alters iris configuration in pigment dispersion syndrome and in normal eyes</article-title>. <source>Ophthalmology.</source> (<year>1995</year>) <volume>102</volume>:<fpage>446</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1016/S0161-6420(95)31001-9</pub-id><pub-id pub-id-type="pmid">7891984</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peng</surname> <given-names>H</given-names></name> <name><surname>Wang</surname> <given-names>F</given-names></name> <name><surname>Li JJ Li</surname> <given-names>JF</given-names></name> <name><surname>Shen</surname> <given-names>XL</given-names></name> <name><surname>Liu</surname> <given-names>GB</given-names></name> <etal/></person-group>. <article-title>Mechanical analysis of the impact of the morphology of the iris and ciliary body on the central vault after posterior chamber phakic intraocular lens implantation</article-title>. <source>Zhonghua Yan Ke Za Zhi.</source> (<year>2022</year>) <volume>58</volume>:<fpage>615</fpage>&#x02013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.cn112142-20220214-00060</pub-id><pub-id pub-id-type="pmid">35959606</pub-id></citation></ref>
</ref-list>
</back>
</article>