Case report: Post-thoracoscopy pendelluft monitoring

Zhibin Xiao1,3 Na Zhang2 Xiajing Zhang4 Wenjun Lu1 Changjun Gao1* Xude Sun1*
  • 1Department of Anesthesiology, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
  • 2Department of Thoracic Surgery, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
  • 3Department of Anesthesiology, The 986th Air Force Hospital, Xijing Hospital, The Air Force Medical University, Xi'an, Shaanxi, China
  • 4Institute of Medical Research, Northwestern Polytechnical University, Xi'an, Shaanxi, China

Asynchronous alveolar ventilation is called pendelluft, which may induce lung injury in spontaneously breathing patients. We report a case that electrical impedance tomography (EIT) was used to assess the pendelluft in a post-thoracoscopy patient. The pendelluft amplitude was as high as 77.5% of the tidal variation. The average regional time shift was 0.5 s. The patient was instructed to adjust the breathing method, symptomatic treatment was performed, and the symptoms were improved. This is the first case reporting pendelluft in a post-thoracoscopy patient. Our case demonstrated that (1) pendelluft may occur in post-thoracoscopy patients and it effects lung function, and (2) early identification of affected patients and implementation of corresponding treatments could improve patient outcomes.

Introduction

In recent years, lung protective ventilation strategies during the perioperative period have been widely used. However, post-operative pulmonary complications can occur from time to time (1, 2). Post-operative pulmonary function recovery can also be time-consuming. Additionally, individualized pulmonary rehabilitation training has not been popularized, one important reason being the current lack of effective clinical methods to assess intrapulmonary ventilation in different regions (2). Pulmonary function defect may occur after minimal invasive surgery, which was not systematically assessed (3). Once the patient recovers spontaneously breathing after surgery, non-uniform transmission of pleural pressure generated by diaphragmatic contraction may cause a phenomenon called pendelluft (4). In the extreme cases such as flail chest, pendelluft volume can be as high as 12.5% of the total volume passing through an airway (5). Although pendelluft could be potentially harmful by introducing local overstretch, tidal recruitment and inflammation, up to now, no traditional technique can track the pendelluft level.

Electrical impedance tomography (EIT) is a novel bedside imaging modality that provides continuous images of pulmonary ventilation and shows regional ventilation changes (6). EIT has been proposed to assess the pulmonary rehabilitation program and inspiratory muscle activities (7, 8), as well as capture the amplitude of pendelluft (9).

We present a case in which significant pendelluft was captured in a patient after thoracoscopy detected by EIT. Pulmonary rehabilitation was conducted for the patient who otherwise would have been discharged. Improvement in pulmonary function was observed after the early intervention.

Case description

A 49-year-old male patient with 10 years history of diabetes was admitted to our hospital. Ground-glass opaque nodules and dense nodular shadows were found in the posterior segment of the upper right lobe of the lung during computed tomography examination. A single-port thoracoscopy resection of S2b + lymph node sampling of the right upper lobe was performed under general anesthesia. The surgery lasted 1 h 55 min and was conducted successfully.

During the follow-up on the day after surgery, the patient had rapid, shallow breathing and was irritable. EIT measurement was conducted (VenTom-100, MidasMED Biomedical technology, Suzhou, China). A belt with 16 equidistantly fixed electrodes was placed around the chest in one transverse plane at the level of the 4th intercostal space at the parasternal line. Raw EIT data were acquired with at a scan rate of 20 images/s using excitation currents of 1 mArms applied through opposite electrodes. Image reconstruction was accomplished by the GREIT algorithm (10). In brief, inspiration and expiration were identified for global and regional impedance-time curves. The impedance differences between the sum of all regional tidal impedance variation (TIV) and the global TIV represented the pendelluft volume. The time shift between the regional and global inspiration start denoted as the pendelluft-induced time differences. EIT revealed asynchronous breathing in the right and left lungs with obvious pendelluft breathing pattern (Figure 1). The pendelluft amplitude was as high as 77.5% of the tidal variation. The average regional time shift was 0.5 s. We suspected that the airways were partially blocked by the sputum, which significantly increased the airway resistance heterogeneously.

FIGURE 1
www.frontiersin.org

Figure 1. Pendelluft amplitude and time differences calculated according to a previous study (9). TV, tidal variation.

To further clarify the patient's lung status, he was then scheduled for a computed tomography examination, the results of which suggested: subcutaneous emphysema in the right thoracolumbar region, right hydropneumothorax and a small amount of fluid in the left pleural cavity, and a patchy high-density shadow in the surgical area of the right lung. The patient was advised to cough up more sputum and practice deep breathing exercises more frequently. After three days of anti-infection, expectorant, and analgesic symptomatic treatment, the patient had a respiratory rate of 24 bpm with no symptoms of chest tightness or dyspnoea, though he still felt shortness of breath after physical activities. The patient was discharged after the removal of the chest drainage tube.

Timeline: Figure 2 showed information about the treatment process.

FIGURE 2
www.frontiersin.org

Figure 2. Timeline of patient treatment.

Diagnostic assessment

Telephone follow-up one month after the operation: the patient felt good, but he had shortness of breath after fast walking. Unfortunately, due to the COVID-19 epidemic, it was inconvenient for the patient to come for re-examination.

Discussion

The pendelluft is a phenomenon of gas redistribution in the lungs due to asynchronous alveolar ventilation. It was found that for patients with acute respiratory failure or intrapulmonary injury who are mechanically ventilated in the ICU, preserving moderate spontaneous breathing can help improve ventilation in the gravity-dependent zone, increase oxygenation, and prevent diaphragmatic atrophy. However, excessive inspiratory efforts have the potential to exacerbate lung injury through the pendelluft mechanism (11, 12). Since the pendelluft phenomenon involves only intrapulmonary gas redistribution and does not change the tidal volume per se, it means that in critically ill patients with lung injury, even if a small tidal volume lung-protective ventilation strategy has been adopted, the pendelluft phenomenon may still cause local regional lung hyperinflation and become a hidden source of lung injury exacerbation (13). During thoracoscopy, one-lung ventilation with positive pressure combined with the extended resection of the S2b in the upper lobe of the right lung may result in a non-uniform transfer of pleural pressure from diaphragmatic contraction. Such non-uniform pleural pressure may cause pendelluft. Due to the limitation of currently well-established techniques, the presence of pendelluft was not reported so far in patients after thoracoscopy (14). Follow-up treatment for the post-thoracoscopy patients could not be provided accordingly. As the first report of its kind, we took advantage of EIT as a bedside tool to detect the pendelluft in timely manner, helping with early treatment and intervention. The patient was instructed to adjust the breathing method, symptomatic treatment was performed, and the abnormal breathing phenomenon disappeared.

The EIT imaging technique has its known limitations: EIT image does not provide the precise anatomical localization of lung tissue and the spatial resolution is relatively low compared to computed tomography or magnetic resonance imaging. Electrode belt cannot be attached to the thorax for EIT measurement when the patients' wounds are around 4th intercostal space after surgery. As a limitation of the study, quantitative assessment of the treatment outcomes was not recorded. Nevertheless, our case demonstrated that (1) pendelluft may occur in post-thoracoscopy patients and it effects lung function, and (2) early identification of affected patients and implementation of corresponding treatments could improve patient outcomes. Further studies are warranted to explore the incidence of pendelluft in such patient group. Randomized controlled trial could be conducted to compare the post-operation recovery with and without EIT-based pendelluft assessment. But EIT does have a very high temporal resolution, which makes the functional imaging possible. In fact, the calculation utilizes the high temporal resolution to estimate the pendelluft phase shift and thereby the corresponding amplitude.

Conclusion

EIT can be used to detect the pendelluft phenomenon in post-thoracoscopy patients at the bedside, which provides important evidence for symptomatic diagnosis and treatment.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding authors.

Ethics statement

The studies involving human participants were reviewed and approved by Ethics Committee of Tangdu Hospital of Air Force Military Medical University. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

XS and CG conceived and designed the study. ZX and NZ performed of the experiments and drafted the manuscript. XZ edited the manuscript. WL analyzed the data. All authors have read and approved the final version of the manuscript.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Gómez-Hernández MT, Forcada C, Varela G, Jiménez MF, Embún R, de Antonio DG, et al. Operating time: an independent and modifiable risk factor for short-term complications after video-thoracoscopic pulmonary lobectomy. Eur J Cardio-Thoracic Surgery. (2022) 62:ezac503. doi: 10.1093/ejcts/ezac503

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Miskovic A, Lumb AB. Postoperative pulmonary complications. Br J Anaesth. (2017) 118:317–34. doi: 10.1093/bja/aex002

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Hashem MD, Nelliot A, Needham DM. Early mobilization and rehabilitation in the ICU: moving back to the future. Respir Care. (2016) 61:971–9. doi: 10.4187/respcare.04741

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Zhao Z, Yuan TM, Chuang YH, Wang YW, Chang HT, Bien MY, et al. Lung ventilation distribution in patients after traditional full sternotomy and minimally invasive thoracotomy: An observational study. Acta Anaesthesiol Scandinavica. (2021) 65:877–85. doi: 10.1111/aas.13759

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Vyshedskiy A, Murphy R. Pendelluft in chronic obstructive lung disease measured with lung sounds. Pulm Med. (2012) 2012:139395. doi: 10.1155/2012/139395

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Harada K, Saoyama N, Izumi K, Hamaguchi N, Sasaki M, Inoue K. Experimental pendulum air in the flail chest. Jpn J Surg. (1983) 13:219–26. doi: 10.1007/BF02469481

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Gong B, Krueger-Ziolek S, Moeller K, Schullcke B, Zhao Z. Electrical impedance tomography: functional lung imaging on its way to clinical practice? Expert Rev Respir Med. (2015) 9:721–37. doi: 10.1586/17476348.2015.1103650

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Yuan S, Chi Y, Long Y, He H, Zhao Z. Effect of position change from the bed to a wheelchair on the regional ventilation distribution assessed by electrical impedance tomography in patients with respiratory failure. Front Med. (2021) 8:744958. doi: 10.3389/fmed.2021.744958

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Zhao Z, Frerichs I, Chang MY, Moller K. Inspiratory muscle training can be monitored by electrical impedance tomography. Aust Crit Care. (2019) 32:79–80. doi: 10.1016/j.aucc.2018.10.004

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Sang L, Zhao Z, Yun PJ, Frerichs I, Möller K, Fu F, et al. Qualitative and quantitative assessment of pendelluft: a simple method based on electrical impedance tomography. Ann Transl Med. (2020) 8:1216. doi: 10.21037/atm-20-4182

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Adler A, Arnold JH, Bayford R, Borsic A, Brown B, Dixon P, et al. GREIT: a unified approach to 2D linear EIT reconstruction of lung images. Physiol Meas. (2009) 30:S35–55. doi: 10.1088/0967-3334/30/6/S03

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Yoshida T, Nakahashi S, Nakamura MAM, Koyama Y, Roldan R, Torsani V, et al. Volume-controlled ventilation does not prevent injurious inflation during spontaneous effort. Am J Respirat Crit Med. (2017) 196:590–601. doi: 10.1164/rccm.201610-1972OC

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Yoshida T, Roldan R, Beraldo MA, Torsani V, Gomes S, De Santis RR, et al. Spontaneous effort during mechanical ventilation: maximal injury with less positive end-expiratory pressure. Crit Care Med. (2016) 44:e678–688. doi: 10.1097/CCM.0000000000001649

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Yoshida T, Torsani V, Gomes S, De Santis RR, Beraldo MA, Costa EL, et al. Spontaneous effort causes occult pendelluft during mechanical ventilation. Am J Respir Crit Care Med. (2013) 188:1420–7. doi: 10.1164/rccm.201303-0539OC

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: electrical impedance tomography, pendelluft, post-thoracoscopy, lung injury, pulmonary ventilation

Citation: Xiao Z, Zhang N, Zhang X, Lu W, Gao C and Sun X (2023) Case report: Post-thoracoscopy pendelluft monitoring. Front. Med. 9:1108637. doi: 10.3389/fmed.2022.1108637

Received: 26 November 2022; Accepted: 27 December 2022;
Published: 02 March 2023.

Edited by:

Rodrigo Torres-Castro, University of Chile, Chile

Reviewed by:

Zhanqi Zhao, Furtwangen University, Germany
Richard Bayford, Middlesex University, United Kingdom

Copyright © 2023 Xiao, Zhang, Zhang, Lu, Gao and Sun. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Changjun Gao, gaocj74@163.com; Xude Sun, sunxude@fmmu.edu.cn; sunxudes@163.com

These authors have contributed equally to this work

Download