@ARTICLE{10.3389/fmicb.2019.02098, AUTHOR={Lau, Anna F. and Walchak, Robert C. and Miller, Heather B. and Slechta, E. Susan and Kamboj, Kamal and Riebe, Katherine and Robertson, Amy E. and Gilbreath, Jeremy J. and Mitchell, Kaitlin F. and Wallace, Meghan A. and Bryson, Alexandra L. and Balada-Llasat, Joan-Miquel and Bulman, Amanda and Buchan, Blake W. and Burnham, Carey-Ann D. and Butler-Wu, Susan and Desai, Uma and Doern, Christopher D. and Hanson, Kimberly E. and Henderson, Christina M. and Kostrzewa, Markus and Ledeboer, Nathan A. and Maier, Thomas and Pancholi, Preeti and Schuetz, Audrey N. and Shi, Gongyi and Wengenack, Nancy L. and Zhang, Sean X. and Zelazny, Adrian M. and Frank, Karen M.}, TITLE={Multicenter Study Demonstrates Standardization Requirements for Mold Identification by MALDI-TOF MS}, JOURNAL={Frontiers in Microbiology}, VOLUME={10}, YEAR={2019}, URL={https://www.frontiersin.org/articles/10.3389/fmicb.2019.02098}, DOI={10.3389/fmicb.2019.02098}, ISSN={1664-302X}, ABSTRACT={ObjectivesRapid and accurate mold identification is critical for guiding therapy for mold infections. MALDI-TOF MS has been widely adopted for bacterial and yeast identification; however, few clinical laboratories have applied this technology for routine mold identification due to limited database availability and lack of standardized processes. Here, we evaluated the versatility of the NIH Mold Database in a multicenter evaluation.MethodsThe NIH Mold Database was evaluated by eight US academic centers using a solid media extraction method and a challenge set of 80 clinical mold isolates. Multiple instrument parameters important for spectra optimization were evaluated, leading to the development of two specialized acquisition programs (NIH method and the Alternate-B method).ResultsA wide range in performance (33–77%) was initially observed across the eight centers when routine spectral acquisition parameters were applied. Use of the NIH or the Alternate-B specialized acquisition programs, which are different than those used routinely for bacterial and yeast spectral acquisition (MBT_AutoX), in combination with optimized instrument maintenance, improved performance, illustrating that acquisition parameters may be one of the key limiting variable in achieving successful performance.ConclusionSuccessful mold identification using the NIH Database for MALDI-TOF MS on Biotyper systems was demonstrated across multiple institutions for the first time following identification of critical program parameters combined with instrument optimization. This significantly advances our potential to implement MALDI-TOF MS for mold identification across many institutions. Because instrument variability is inevitable, development of an instrument performance standard specific for mold spectral acquisition is suggested to improve reproducibility across instruments.} }