This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
In the original article, there was a mistake in Table
PET, SPECT, CT, and MR specifications of selected dual and triple modality clinical systems commercially available.
[18] | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PET specifications | Scintillator | – | – | – | LSO | LYSO | LYSO | LYSO | BGO | LYSO | LYSO | LYSO | LYSO | LYSO | LSO | LYSO | LBS |
Crystal size (mm3) | – | – | - | 4 × 4 × 20 | 4 × 4 × 22 | 4 × 4 × 19 | 4.2 × 6.3 × 25 | 6.3 × 6.3 × 30 | 4 × 4 × 12 | 3.63 × 3.63 × 20 | 2.35 × 2.35 × 15 | 2.76 × 2.59 × 18 | 3.9 × 3.9 × 20 | 4 × 4 × 20 | 4 × 4 × 22 | 4.2 × 5.3 × 25 | |
Total detector elements | – | – | – | 32 448 | 28 336 | 23 040 | 13 824 | 11 520 | 30 720 | 37 632 | 110 592 | 101 920 | 39 672 | 28 672 | 28 336 | 20 160 | |
Photo-detector | – | – | – | PMT | PMT | dSiPM | PMT | PMT | PMT | PMT | PMT | SiPM | PMT | APD | PMT | SiPM | |
ToF capability | – | – | – | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | No | No | Yes | Yes | |
Patient bore (cm) | – | – | – | 78.0 | 71.7 | 70.0 | 70.0 | 74.0 | 88.0 | N.A. | 70.0 | 70.0 | 70.0 | 60.0 | 70.7 | 60.0 | |
Transaxial FOV (cm) | – | – | – | 81.5 | 67.6 | N.A. | 70.0 | 70.0 | 70.0 | N.A. | 70.0 | 70.0 | 55.0 | 59.4 | N.A. | 60.0 | |
Axial FOV (cm) | – | – | – | 21.8 | 18.0 | 16.4 | 15.7 | 26.0 | 19.6 | N.A. | 23.6 | 30.0 | 23.0 | 25.8 | 18.0 | 25.0 | |
Energy window (keV) | – | – | – | 435–650 | 440–665 | N.A. | 425–650 | 425–650 | 425–650 | 425–650 | N.A. | LLD, 430 | N.A. | 430–610 | 460–665 | 425–650 | |
Energy resolution (%) | – | – | – | 11.5 | 11.1 | 11.1 | 12.4 | N.A. | 12.4 | N.A. | N.A. | N.A. | N.A. | 14.5 | 11.6 | 11.0 | |
Time coincidence window (ns) | – | – | – | 4.1 | 4.5 | 4.0 | 4.9 | 9.5 | 1.6–3.2 | 4.1 | N.A. | N.A. | 5.0 | 5.9 | 6.0 | 4.6 | |
Time resolution (ns) | – | – | – | 0.5 | 0.5 | 0.3 | 0.5 | N.A. | 0.4 | 0.43 | 0.485 | N.A. | N.A. | 2.9 | 0.5 | 0.4 | |
Transaxial Resolution 1 cm/10 cm (mm) | – | – | – | 4.4/4.9 | 4.8/5.1 | 4.1/4.5 | 4.7/5.0 | 4.5/5.4 | 5.1/5.1 | 3.76/4.56 | 2.85/3.07 | Max resol. 2.9 | 4.1/4.9 | 4.3/5.0 | 4.7/5.1 | 4.2/5.2 | |
Axial Resolution 1 cm/10 cm (mm) | – | – | – | 4.4/5.9 | 4.7/5.2 | 4.0/4.3 | 4.7/5.6 | 4.8/4.8 | 5.0 /5.4 | 3.64/5.29 | 3.01/2.97 | 4.2/5.1 | 4.3/6.6 | 4.6/5.0 | 5.8/7.1 | ||
Sensitivity (kcps/MBq) | – | – | – | 9.7 | 7.3 | 5.7 | 7.4 | 22.8 | 3.8 | 10.9 | 8.3 | 16 | 8.1 | 15.0 | 7.0 | 21.0 | |
Scatter Fraction (%) | – | – | – | 33.2 | 36.7 | 30.0 | 37.0 | 36.2 | 37.3 | N.A. | 38.4 | 40.0 | N.A. | 37.9 at peak NECR | 26.0 | 43.6 at peak NECR | |
Peak NEC (kcps @ kBq/mL) | – | – | – | 180 @ 28 | 124 @ 20.3 | 171 @ 50 | 139 @ 29 | 124 @ 9.1 | 70 @ 29.6 | 224.6 @ 29.0 | 109 @ 21.5 | 170 @ 16.0 | 150 @ N.A. | 184 @ 23.1 | 89 @ 13.7 | 210 @ 17.5 | |
SPECT specifications | Detector type | 3.8 in. NaI | 3.8 in. NaI | 3.8 in. NaI | – | – | – | – | – | – | – | – | – | NaI | – | – | – |
Photo-detector | PMT | PMT | PMT | – | – | – | – | – | – | – | – | – | 60(48) PMT | – | – | – | |
Detector size (cm) | 38.7 × 53.3 | 40.6 × 54.0 | 40.0 × 54.0 | – | – | – | – | – | – | – | – | – | 58.5(55.8) × 47.0(41.8) | – | – | – | |
CT specifications | Max CT slices | 2,6,16 | 16 | Cone beam | 128 | 128 | 128 | 64 | 16 | 16 | 64 | 16 | 128 | 16 | – | – | – |
CT tube max voltage (kVp) | 130 | 140 | 120 | 140 | 140 | 140 | 140 | 140 | 135 | 140 | 140 | 140 | 140 | – | – | – | |
CT tube max current (mA) | 345 | 440 | 80 | 800 | 665 | 665 | 800 | 440 | 600 | 667 | 420 | 833 | 500 | – | – | – | |
Max CT rotation (s) | 0.5 | 0.5 | 12 | 0.3 | 0.4 | 0.4 | 0.35 | 0.5 | 0.5 | 0.39 | 0.5 | 0.3 | 0.4 | – | – | – | |
MR specifications | PET/MR integration | – | – | – | – | – | – | – | – | – | – | – | – | – | Fully integrated | Sequential | Fully integrated |
Magnet | – | – | – | – | – | – | – | – | – | – | – | – | – | Superconductor | Superconductor | Superconductor | |
Magnetic field | – | – | – | – | – | – | – | – | – | – | – | – | – | 3T | 3T | 3T | |
Magnet length (cm) | – | – | – | – | – | – | – | – | – | – | – | – | – | 163 | 157 | N.A. | |
Magnet bore (cm) | – | – | – | – | – | – | – | – | – | – | – | – | – | 60 | 60 | 60 | |
Maximum FOV (cm3) | – | – | – | – | – | – | – | – | – | – | – | – | – | 60 | 50 × 50 × 45 | 50 × 50 × 50 |
The original article has been updated.