This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Many Electronic Nicotine Delivery Systems (ENDS) employ integrated sensors to detect user puffing behavior and activate the heating coil to initiate aerosol generation. The minimum puff flow rate and duration at which the ENDS device begins to generate aerosol are important parameters in quantifying the viable operating envelope of the device and are essential to formulating a design of experiments for comprehensive emissions characterization. An accurate and unbiased method for quantifying the flow condition operating envelope of ENDS is needed to quantify product characteristics across research laboratories. This study reports an accurate, unbiased method for measuring the minimum and maximum aerosolization puff flow rate and duration of seven pod-style, four pen-style and two disposable ENDS. The minimum aerosolization flow rate ranged from 2.5 to 23 (mL/s) and the minimum aerosolization duration ranged from 0.5 to 1.0 (s) across the ENDS studied. The maximum aerosolization flow rate was defined to be when the onset of liquid aspiration was evident, at flow rates ranging from 50 to 88 (mL/s). Results are presented which provide preliminary estimates for the effective maximum aerosolization flow rate and duration envelope of each ENDS. The variation in operating envelope observed between ENDS products of differing design by various manufacturers has implications for development of standardized emissions testing protocols and data reporting required for regulatory approval of new products.
There is little consistency in puffing regimes being used for ENDS emission studies; studies have used 15 ml/s, 4 s puffs (
The FDA 2016 draft guidance for Pre-Market Tobacco Application, PMTA, for ENDS (81 FR 28781) suggests manufacturers consider the chemical and physical identity and quantitative levels of aerosol emissions under the range of operating conditions and use patterns within which consumers are likely to use the new tobacco product. Previous protocols for combustible cigarettes, influenced by the tobacco industry, resulted in inaccurate emissions that did not represent exposure under actual use conditions (
The operating envelope of an ENDS is bounded by the Minimum and Maximum Aerosolization Flowrate (MinAF, MaxAF), and the Minimum and Maximum Aerosolization Duration (MinAD, MaxAD). The MinAF is the puff flow rate above which the ENDS coil consistently activates on every puff and generates TPM yield per puff above the limit of quantitation measurable by the analytical balance. The MaxAF is the puff flow rate below which the ENDS aerosolizes E-Liquid and above which E-Liquid aspiration onset is observed. The MinAD is the puff duration above which the ENDS coil consistently activates on every puff and generates TPM yield per puff above the limit of quantitation. The MaxAD is the puff duration above which no incremental TPM is generated, most likely because the coil has been deactivated by the ENDS power control unit. In the absence of natural environment topography to inform protocols for machine-generated puffing profiles, characterizing products over the entire operating envelope describes the full range of exposure possible for a given ENDS.
Selection of devices to study was based on their relevance in the current ENDS market, product attributes, operating parameters of devices, and manufacturers of ENDS products. We chose to study popular products on the US ENDS market, with a focus on popular products with ohm/sub-ohm coils and “tobacco” flavor e-liquid options. Priority was given to devices with disposable (non-refillable) tanks and fixed (non-user adjustable) power. We selected products from a variety of manufacturers.
In general, the market has trended toward more widespread use of “pod style” devices, an increase in customizability in “mod style” devices, and a trend away from “pen style” ENDs for nicotine use. Additionally, disposable devices that visually resemble pod style products, sometimes referred to as “smoke bars,” have become popular throughout 2020. Meanwhile, pen style ENDS are still relevant for users of Cannabidoil (CBD) and tetrahydrocannabinol (THC) containing e-liquids and oils.
The majority of ENDS product literature refers to the power control unit (PCU) with the benign title “battery,” obfuscating the fact that the PCU often contains sophisticated power management and control logic. Some e-cigarettes have incorporated 510 threads (10 male threads at 0.5 mm pitch with a diameter of 7 mm, aka M7 × 0.5) onto their PCUs to make them compatible with 510 reservoirs. These 510 reservoirs seem to be a product of choice, alongside pods, for mid-chain triglyceride (MCT) solvent e-liquids containing CBD and THC. Therefore, priority was put on choosing pen style products that use a 510 thread. Keyword searches such as “510 batteries” and “510 cartridges” returned ENDS-relevant results for “pen style” devices. While pen style products are not fully customizable, it was observed that some PCUs often offer approximately three discrete voltage settings which users can vary by pushing the activation button in a specific way (e.g., triple click). Devices enabling user adjustable power were not selected for this study. Some ENDS reservoirs are sold with the heating coil integrated into the reservoir, often marketed as with the name “pods” or “cartridges,” while other ENDS reservoirs permit the user to interchange the heating coil. This study focuses primarily on products with reservoirs having integrated heating coils. The ENDS PCU, reservoir and heating coil may each contribute in novel ways to the emissions generated by the device. Thus, it is important to accurately characterize each ENDS product tested to permit meaningful comparisons between products.
The primary objective of this study was to demonstrate an accurate, unbiased method for quantifying the effective operating envelope of ENDS in terms of four parameters: the minimum and maximum aerosolization puff flow rate and duration, denoted MinAF, MaxAF, MinAd, and MaxAd, respectively. The second objective is to report ENDS packaging and product characteristics and descriptive statistics of the nominal coil resistance, Rcoil, and nicotine mass ratio, fNic, expressed as mg of nicotine per mg of aerosolized TPM and un-puffed E-Liquid for each ENDS studied. These product characteristics are proposed for PMTA reporting under 81 FR 28781.
A summary of the ENDS assessed herein in presented in
Test specimens used in screening trials for this study.
ENDS Model | JUUL | Alto | Novo 2 | myblu | Ace | Caliburn | Breeze 2 | Titan | Logic Pro | Hyde | Vibe | Smok Stick | Puff Bar |
ENDS Style | Pod | Pod | Pod | Pod | Pod | Pod | Pod | Pen | Pen | Single use | Pen | Pen | Single use |
Rechargeable PCU | X | X | X | X | X | X | X | X | X | X | X | X | |
Refillable reservoir | X | X | X | X | |||||||||
Replaceable coil | X | X | X | ||||||||||
Adjustable power | By Coil | By Coil | By Coil | ||||||||||
Actuation type | Puff | Puff | Puff | Puff | Puff | Button | Button and Puff | Puff | Button | Puff | Puff | Button | Puff |
PCU form factor | Rect. | Rect. | Rect. | Rect. | Ovoid | Rect. | Rect. | Cyl. | Cyl. | Rect. | Cyl. | Cyl. | Rect. |
Reservoir capacity (mL) | 0.7 | 1.8 | 2 | 1.5 | 1.9 | 2 | 3 | 1 | 1.5 | 1.8 | 1.9 | 8 | 1.3 |
Assembled dimensions (mm)Axial × lateral × vertical | 94.7 × 15.1 × 6.9 | 104.6 × 19.1 × 10.6 | 88.5 × 24.2 × 14.5 | 106.7 × 18 × 9.5 | 88.3 × 29.8 OD × 13.5 OD | 109.9 × 21.2 × 11.8 | 94.5 × 35 × 20 | 121.7 × 9.3 OD | 136.6 × 14.1 OD | 79.6 × 24.7 × 7.6 | 136.8 × 13 OD | 146 × 24.4 OD | 96.6 × 15.6 × 6.5 |
Mfg stated battery chemistry | NR | LiPo | NR | NR | NR | NR | NR | NR | LiOn | LiOn | LiOn | NR | NR |
Mfg stated battery capacity (mAHr) | NR | 350 | 800 | 350 | NR | 520 | 1,000 | 300 | 650 | 380 | 600 | 3,000 | 350 |
Mfg stated coil resistance (ohm) | NR | NR | 1.0, 1.4 | 1.3 | NR | 1.4 | 0.6, 1.0 | 2.3 | 2.3 | NR | NR | 0.17 | NR |
NR | NR | 6–25 W | 10.5 W | NR | 11 W Max | NR | NR | 3.70 V and 2.3 Ohms | NR | NR | 30–70 W | NR | |
Eliquid manufacturer | JUUL Labs | VUSE | Mad Hatter Juice | Blu | NJOY | Mad Hatter Juice | Mad Hatter Juice | Vapor4Life | Logic | Hyde | VUSE | Mad Hatter Juice | Puff Bar |
Eliquid branded flavor name | Virginia Tobacco | Original | Classic Tobacco | Classic Tobacco | Classic Tobacco | Classic Tobacco | Classic Tobacco | Wowbacco | Tobacco | Spear Mint | Original | Classic Tobacco | Tobacco |
Eliquid branded nicotine concentration | 5% | 5% | 50 mg/5% by vol. | 2.40% | 5% by wt. | 50 mg / 5% by vol. | 50 mg / 5% by vol. | 3.60% | 20 mg/ml | 50 mg | 3% | 50 mg / 5% by vol. | 5% |
Place of purchase | M, R | O, R | M | M | M | O | M | M | O | O | R | O | M |
Country of manufacturer | China (PCU) USA (Res) | China (PCU)USA (Res) | China | China | China (PCU) USA (Res) | China | China | NR | China | China | China (PCU) USA (Res) | China | China |
Parent company | JUUL Labs; Altria | RJRVC; Reynolds America | Shenzhen IVPS Technology Co. | Imperial Brands; Fontem US | NJOY LLC | Shenzhen Uwell Technology Co. | Shenzhen Eigate Technology Co. | Vapor4Life | Logic Technology Development, LLC | Loontech | RJRVC; Reynolds America | Shenzhen IVPS Technology Co. | NR |
Image of the thirteen ENDS products tested for this investigation.
Each ENDS PCU was documented as it was unpackaged, to observe all labeling on the outer and inner packaging as received from the vendor. The product manufacturer was noted for each device, and ENDS “Product Model” is used as a legend key for subsequent presentation of results. Several attributes of each device were noted, including whether the PCU was rechargeable, the general geometric form factor (shape) of the PCU, and if its e-liquid reservoir was refillable. Most devices studied herein had a coil integrated with the reservoir, while three products permitted user replacement of the coil in the reservoir. The packaging and user instructions were evaluated to determine if each device was flow rate activated, “puff,” or manually activated, “button.” None of the products tested permitted the user to make adjustments to the power, except for the Aspire Breeze 2, SMOK Novo 2, and SMOK Stick which permit users to replace the coil in the reservoir and thereby influence the power dissipated in the coil.
We measured the assembled dimensions of the ENDS PCU plus reservoir in their nominal configuration as intended for use. The volumetric capacity of the reservoir as stated by the manufacturer was recorded, along with the name of the manufacturer of the e-liquid used for each product test. In those cases when the manufacturer provided non-refillable reservoirs, we elected to use e-liquid product from the same manufacturer, marketed for sale with the PCU, and chose the “tobacco” flavored e-liquid. All products which provided refillable reservoirs were operated with a common lot of bulk “classic tobacco” e-liquid manufactured by Mad Hatter Juice. We observed non-uniformity in the units employed to report nicotine concentration of e-liquid, and report the values as observed on the product packaging.
We observed the majority of product packages did not report the battery chemistry, battery capacity, coil resistance, or operating power of the product, and there was non-uniformity in reporting these characteristics between product manufacturers and models. Any data not reported on the external or internal packaging is indicated as “Not Reported (NR)” in
Each ENDS Power Control Unit (PCU) and ENDS Reservoir (pod or tank with integrated coil and wick) to be tested was marked with a unique identification number and QR code assigned by the lab. These unique identifiers were scanned prior to each measurement and emissions trial and recorded by data logging scripts. All data measurements and analysis results are traceable by these unique identifiers.
The analytical balance used for this study was a Mettler Toledo Model Number AE240-1 S/N J65956 with a manufacturer reported readability of 0.1 (mg), approximate accuracy of 0.4 (mg) and full scale range of 200 (grams) with a linearity of ± 0.02 (mg) mounted on a heavy work bench to minimize vibration effects. The analytical balance was used to measure the mass of each ENDS reservoir and filter pad “before” and “after” each trial. The decrease in the mass of the ENDS reservoir is one measure of the Total Particulate Matter (TPM) generated by the ENDS via aerosolization while the increase in the mass of the filter pad is a measure of the TPM delivered to the user over the same time interval. When the ENDS Yield (mass decrease) is nearly equal to the Pad Yield (mass increase) there is high confidence that minimal TPM deposition has occurred between the ENDS device and the filter pad in the flow path of the emissions test system.
Sample loading and unloading was done carefully to avoid disturbing the balance, and each sample was positioned near the center of the sample pan, with gentle opening and closing of the balance doors. The analytical balance was maintained at room temperature in the lab, and located in a corner away from drafts and room air ducting. The analytical balance was routinely turned on and allowed to warm up for at least 1 h before taking measurements. Prior to each test series, the analytical balance was confirmed to be level using the bubble level built into the instrument. The accuracy of the balance was verified with its internal standard prior to the beginning of each measurement session. The balance was tared to assure a reading of 0.0000 (gram) prior to placing a sample on the measurement pan.
The limit of detection (LoD) was assumed equal to the gravimetric instrument accuracy at the low end of the measurement range, LoD = 0.4 (mg). The limit of quantitation (LoQ) (
The effective resistance of the coil and reservoir to PCU connection was measured using a four-wire constant current resistance measurement method as introduced in (
Emissions were machine-generated using two sets of puffing profiles: “variable flow rate set” and “variable duration set.” The number of different durations and flow rates run in each set depended on the individual behavior of the product. There were at least 10 profiles run in the variable flow rate set, and each profile had nominally 50 homogeneous square-wave puffs of 3.5 (s) and flow rates ranging from nominally 10 (mL/s) up to 100 (mL/s) for the different profiles in the set. Similarly, there were at least 10 profiles run in the variable duration set, and each profile had nominally 50 homogeneous square-wave puffs of 30 (mL/s), and puff durations ranging from nominally 0.5 to 10 s for the different profiles in the set. All profiles had a nominal puff period of 30 s.
At shorter puff durations or lower flow rates, some products did not activate, and the operator had discretion to conduct additional trials to narrow in on the minimum puff duration or minimum flow rate at which the ENDS began to generate measurable TPM. At higher puff durations or higher flow rates, the operator would limit the number of puffs in the profile to <50 puffs, to ensure the coil remained supplied with e-liquid throughout. For example, one high powered ENDS, when operated for long duration puffs, consumed liquid in the reservoir over only 20 puffs. In those cases, the operator adjusted the series of trials to achieve nominally 50 puffs per flow condition while ensuring that no single emissions profile exhausted the liquid supply or over-loaded the filter pad. For some products, particularly with higher puff flow rates, the operator would need to adjust the range of flow rates studied when significant deposition was visually observed in the tubing of the puffing machine between the exit plane of the ENDS and the entrance to the filter pad.
All emissions tests were conducted using the PES-1 system, previously described (
NMR analysis was conducted on un-puffed E-Liquid samples taken from each product tested to determine the proportion of propylene glycol to the glycerin which formed the solvent base for the liquid. The instrument used for NMR was a Bruker Advance III 500 MHz NMR (Billerica MA). Approximately 10 mg of an e-liquid was added to an NMR tube followed by 600 μL of D2O and a typical NMR spectrum was obtained. After NMR spectra were obtained the spectra were processed using KnowItAllTM spectral processing software (Wiley). For each sample, the water peak was centered at 4.79 ppm and baseline was corrected to ensure proper integration. Peaks for propylene glycol (3.38–3.47 ppm, 1H) and glycerol (3.605–3.675 ppm, 2H) were integrated and molar ratios of each were determined. The integration ranged varied for e-liquids with acid added (known as salted e-liquids) as pH will slightly shift NMR peaks. Volume and mass ratios were calculated for each solution using known density and molar mass of each. To confirm the validity of the method, mixtures of propylene glycol and glycerol (mass ratios: 0:100, 25:75, 50:50, 75:25, 100:0) were prepared and analyzed using the described method. In all cases, correct ratios were confirmed for each test mixture.
GC-MS analysis was conducted to determine the mass ratio of nicotine to total particulate matter from the condensed aerosol captured on the filter pad during emissions trials. Emissions trials above the mass limit of detection were analyzed. Mass of nicotine in the aerosol was determined in the same manner as previously reported (
Three figures were generated for each ENDS model and used collectively to assess the effective operating envelope of each product (not shown). The emissions testing of each model may require multiple devices (ENDS PCUs and Reservoirs) as reported in the Results. All devices associated with a particular ENDS model were analyzed together. The figures included a scatter plot of (1) pad yield per-puff YTPM (mg/puff) vs. mean puff flow rate q (mL/s) for the “variable flow rate set” of conditions, (2) YTPM (mg/puff) vs. mean puff duration d (s) for the “variable duration set” of conditions, and (3) relative gravimetric error ΔM (%) vs. q (mL/s) for the “variable flow rate set” of conditions.
Each figure was annotated with notes recorded by the operator during trials. For example, the operator recorded when an LED indicator behaved in a different manner. Some ENDS devices, for example, documented the LED would change color when the battery dropped below a predefined voltage or when the maximum puff duration was exceeded. Observations of the LED were then compared with other quantifiable characteristics, such as changes in TPM pad yield per puff. The operator noted if any bubbles appeared to be generated in the ENDS Reservoir, if droplets were evident in the connection between the exit plane of the ENDS device and the surface of the filter pad, or if discrete droplets or gravity distribution of deposition pattern were evident on the filter pad. Likewise, the operator noted if there was a significant increase in the coil resistance between the “before” and “after” resistance measurements when using the fixture 4 wire resistance measurement method (
After all three scatter plots were generated and annotated for each ENDS, the analyst interpreted the yield results in the context of the emission operator's notes. The analyst determined four parameters to characterize the effective operating envelope of each ENDS: (1) the minimum aerosolization flow rate (MinAF), (2) the maximum aerosolization flow rate (MaxAF), (3) the minimum aerosolization duration (MinAD), and (4) the maximum aerosolization duration (MaxAD).
The MinAF was defined as the lowest puff flow rate at which the ENDS device consistently activated and generated aerosol, while the puff duration was held fixed at nominally 3.5 sec. The MinAF simultaneously (1) generated yield above the per-puff LoQ, YTPM ≥ 0.04 (mg/puff) for the “variable flow rate set” of conditions, (2) exhibited a relative gravimetric error, ΔM ≈ ≤ 10 (%), and (3) appeared to consistently activate the ENDS coil based on operator observations. The error bound on the MinAF were taken to be the difference between trial conditions wherein constraints 1 through 3 were and were not consistently satisfied.
The MaxAF were defined as the lowest flow rate at which there was visual and gravimetric evidence of aspiration, while the puff duration was held fixed at nominally 3.5 s. The MaxAF simultaneously (1) exhibited a sudden sharp increase in the slope of the YTPM vs. q curve, (2) exhibited a relative gravimetric error, ΔM > 10 (%), and (3) exhibited evidence of liquid suction in addition to or in place of aerosolization as reflected by operator observations and photographs. The error bound on the MaxAF were taken to be the difference between flow conditions wherein constraints 1 through 3 were and were not consistently satisfied. If the MaxAF could not be determined definitively for the conditions tested, the maximum flow rate tested was recorded.
The MinAD were defined as the lowest puff duration at which the ENDS device consistently activated and generated aerosol while the nominal puff flow rate was held fixed at ~30 mL/s. The MinAD simultaneously (1) generated yield above the per-puff LoQ, YTPM ≥ 0.04 (mg/puff) curve, (2) exhibited a relative gravimetric error, ΔM ≈ ≤ 10 (%), and (3) appeared to consistently activate the ENDS coil based on operator observations. The error bound on the MinAD were taken to be the difference between duration conditions wherein constraint 1 through 3 were and were not consistently satisfied.
The MaxAD were defined as the upper time limit above which the ENDS no longer provided power to the coil. Many, not all, ENDS manufacturers cut off the current provided to the coil after some manufacturer-determined time limit, and this feature is not reported by most manufacturers. The MaxAD simultaneously (1) exhibited a distinct flattening of the YTPM vs. d curve, (2) exhibited a relative gravimetric error, ΔM ≈ ≤ 10 (%), and (3) appeared consistent with operator visual and audible observations of ENDS behavior. The error bound on the MaxAD were taken to be the difference between conditions wherein constraints 1 through 3 were and were not consistently satisfied. If the MaxAD could not be determined definitely for the conditions tested, the maximum duration tested was recorded.
Minimum and maximum activation flow rate, MinAF and MaxAF, for 5 of the 13 ENDS devices tested. Shown is the mean TPM yield per puff for each flow rate condition, based on nominally 50 puffs per flow rate conditions. Puffs were square-wave and nominally 3.5 s in duration, with 30 s puff period.
Consider the button activated Ace device which generated low TPM at flow rates of 2.6 and 4.9 (mL/s) with a noticeable increase at 7.3 (mL/s). The MinAF for the Ace was declared to be 6 ± 1.2 (mL/s). Similarly, the MinAF was declared to be 9.75 ± 3.5, 12 ± 2.4, and 23 ± 1.2 (mL/s) for the Vibe, Juul, and myBlu, respectively. The Novo 2 exhibited erratic behavior between 12 and 18 (mL/s). Operator notes indicated the device failed to “fire consistently” for every puff, and trials also exhibited relatively large gravimetric error, shown in a subsequent figure. The Novo 2 appeared to be fully activated at flow rates above 24 (mL/s) and essentially inactive at flow rates below 22 (mL/s). Thus, the MinAF for the Novo 2 was declared to be 21.3 ± 2.5 (mL/s) with the broad error bar indicating the observed variability in the ENDS performance. The maximum pad yield per puff was YTPM, Max ≈13 (mg/puff) for the Novo 2 and the lowest was YTPM, Max ≈ 2 (mg/puff) for the Juul, which was also the minimum value of YTPM, Max across the 13 products studied. Conversely, the Stick Prince, presented in
Minimum and maximum activation duration, MinAD and MaxAD, for 5 of the 13 ENDS devices tested. Shown is the mean TPM yield per puff for each duration condition, based on nominally 50 puffs per flow rate conditions. Puffs were square-wave and nominally 30 ml/s, with 30 s period.
The five PCUs are useful to illustrate unique features evident across the family of thirteen devices tested. First, we observe the myBlu response, which exhibits a linear increase in pad yield per puff (at this fixed flow rate) until a duration of 10 (s) is achieved, at which point the yield curve flattens out. This is consistent with operator observations that the PCU de-energized after approximately MaxAD ≈ 10 (s) puff duration. The Ace PCU curve exhibited similar response, with the PCU de-energizing at approximately MaxAD ≈ 5.5 (s) as supported by both operator observation and manufacturer documentation. The Vibe PCU exhibited similar response; the operator notes indicate a cut-off at approximately MaxAD ≈ 6 (s), with greater variability in emissions yield from Vibe relative to the other ENDS. The Novo 2 PCU exhibited a fundamentally different response. The expected linear increase of yield with duration (at fixed flow rate) was observed until 8 (s), but then a dramatic increase in yield was observed. Operator notes taken during the last two trials indicated visual evidence of liquid being suctioned from the ENDS reservoir, and deposited between the exit plane of the ENDS and the entrance to the filter pad surface [a distance of <1 (cm)], which we declare as the onset of aspiration. The Juul ENDS exhibited a comparatively constant pad yield per puff as a function of duration (at fixed flow rate) though some linearly increasing trend is implied between 4 and 7 (s).
Relative gravimetric measurement error related to operator observed aspiration during the “Variable Flow Rate set” of conditions shown in
The analysis described in the methods and illustrated by
Nominal operating envelope and emissions characteristics of test specimens used in this study.
Eliquid manufacturer | JUUL Labs | VUSE | Mad Hatter Juice | Blu | NJOY | Mad Hatter Juice | Mad Hatter Juice | Vapor4Life | Logic | Hyde | VUSE | Mad Hatter Juice | Puff Bar |
Number of ENDS PCU's tested | 1 | 5 | 1 | 1 | 1 | 1 | 1 | 2 | 1 | 8 | 1 | 1 | 5 |
Number of ENDS reservoirs tested | 5 | 41 | 1 | 13 | 9 | 1 | 1 | 6 | 8 | 8 | 6 | 1 | 5 |
Min AF (mL/s) | 12 ± 2.4 | 15.8 ± 1.1 | 21.3 ± 2.4 | 23 ± 1.2 | 6 ± 1.2 | 11.8 ± 2.25 | 2.5 ± 2 | 12.2 ± 2.5 | 2.6 ± 2.25 | 16 ± 1.6 | 9.75 ± 3.75 | 2.5 ± 2.5 | 14 ± 4 |
Max AF (mL/s) | >85 ± 5 | 50 ± 2 | 58 ± 10 | 88 ± 5 | 58 ± 5 | > 88 | ~30 @ d > 8 s | > 50 | >48 | >86 | 68 ± 5 | ADR | >50 |
Min AD (s) | 0.5 ± 0.25 | 0.85 ± 0.15 | 0.9 ± 0.15 | 1 ± 0.25 | 0.5 ± 0.25 | 0.5 ± 0.25 | 1 ± 0.52 | 1 ± 0.25 | 0.75 ± 0.25 | 0.5 ± 0.25 | 1 ± 0.25 | 1 ± 0.25 | 1 ± 0.25 |
Max AD (s) | 6.5 ± 0.5 | 5.0 ± 0.1 | 8 ± 0.5 | 10 ± 0.5 | 5.5 ± 0.5 | >10 | 10.5 ± 0.25 | 10 ± 0.25 | >10 | >10 | 6 ± 0.5 | 8 ± 0.25 | >3.5 |
Number of fNic samples | 21 | 135 | 13 | 17 | 25 | 27 | 24 | 15 | 27 | 20 | 11 | 38 | 11 |
fNic Mean (-) | 0.046 |
0.0468 | 0.0503 | 0.0256 | 0.055 | 0.046 | 0.036 | 0.0305 | 0.0211 | 0.0596 | 0.0315 | 0.0496 | 0.0454 |
fNic Median (-) | 0.046 |
0.0464 | 0.05097 | 0.025 | 0.055 | 0.046 | 0.039 | 0.0295 | 0.0197 | 0.0607 | 0.0304 | 0.0523 | 0.0486 |
fNic Std Dev (-) | 0.003 |
0.0048 | 0.0038 | 0.0033 | 0.0046 | 0.0037 | 0.009 | 0.00296 | 0.007 | 0.0041 | 0.005 | 0.0058 | 0.0063 |
Eliquid nicotine mass ratio (-) | 0.052 | 0.052 | 0.039 | 0.02 | 0.05 | 0.039 | 0.039 | 0.023 | 0.016 | 0.0503 | 0.030 | 0.039 | 0.048 |
Eliquid nicotine mass ratio StDev (-) | 0.0005 | 0.0008 | 0.0019 | 0.0012 | 0.0002 | 0.0019 | 0.0019 | 0.0009 | 0.0009 | 0.0017 | 0.0004 | 0.0019 | NR |
Eliquid molar ratio PG:GL | 33:67 | NR | 44:56 | 42:58 | 48:52 | 44:56 | 44:56 | 73:27 | 77:23 | NR | 23:77 | 44:56 | 54:56 |
Eliquid mass ratio PG:GL | 29:71 | NR | 39:61 | 38:62 | 43:57 | 39:61 | 39:61 | 69:31 | 74:26 | NR | 20:80 | 39:61 | 50:50 |
Eliquid volume ratio PG:GL | 33:67 | NR | 44:56 | 42:58 | 48:52 | 44:56 | 44:56 | 73:27 | 77:23 | NR | 23:77 | 44:56 | 54:56 |
R measurement method | F4W | F4W | M4W | F4W | F4W | M4W | M4W | M4W | M4W | M4W | M4W | M4W | M4W |
Number of coil R measured | 16 | 17 | 3 | 18 | 8 | 3 | 1 | 4 | 8 | 1 | 6 | 2 | 1 |
Effective coil resistance mean (ohm) | 1.633 | 1.063 | 1.463 | 1.416 | 1.034 | 1.405 | 0.631 | 2.258 | 2.443 | 1.61 | 2.693 | 0.174 | 1.688 |
Effective coil resistance StDev (ohm) | 0.033 | 0.075 | 0.047 | 0.017 | 0.079 | 0.013 | 0 | 0.053 | 0.077 | 0 | 0.018 | 0.006 | 0 |
The results presented herein are for 13 ENDS products of either pen- or pod-style designs, and share a common attribute of no user-adjustable power options (other than swapping coils), and no user adjustable flow path (e.g., variable inlet restrictors). The study investigated both flow- and button-activated coil designs and disposable and refillable reservoirs. The numerical values presented in the results, discussion and conclusion may thus be limited to pen- and pod-style ENDS. The screening method and outcome measures may be broadly applied to a variety of inhaled tobacco products including ENDS, combustibles and heated tobacco products (also referred to as “Heat Not Burn”).
This article has presented a comparative evaluation of the effective operating envelope of thirteen popular ENDS (pod and pen-style) products. Concurrently, the article demonstrated a robust method for empirically quantifying the operating envelope of ENDS products. The method may be used to compare operating envelope and emissions characteristics between ENDS products and may enable data sharing and reproducibility studies between research laboratories.
ENDS products have the ability to limit the maximum coil activation time and hence TPM per puff.
The maximum aerosolization duration, MaxAD, after which the ENDS power control unit de-energizes the coil, varies widely between ENDS products. All thirteen ENDS products permitted puff durations of at least 5 s. Five products energized the coil for puff durations between 5 and 7.5 s, five products between 7.5 and 10 s, and three products continued to energize the coil for more than 10 s (the maximum duration studied in these experiments). There is no doubt that limiting the coil activation duration time, MaxAD, is feasible; this is a product characteristic which may be regulated and has a direct correlation with the per-puff TPM delivered to a user.
We observed a correlation between the nicotine mass ratio in the un-puffed e-liquid (denoted Eliquid nicotine mass ratio in
We conclude that, for moderately powered pen-style and pod-style devices, it is a reasonable first-order approximation to assume the mass ratio of nicotine present in the aerosol emissions is similar to the mass ratio of nicotine in the un-puffed E-Liquid. Pagano et al. (
ENDS are known to produce condensation aerosols which contain submicron particles suspended in vapor and inhalable by the user. However, we observed at high flow rates formation of droplets in the flow path of the emission system and in some cases formation of bubbles within the un-puffed E-Liquid in the ENDS Reservoir. We hypothesize this phenomena, which we have named E-Liquid aspiration, to result from excess suction pressure in the reservoir at high flow rates sufficient to overcome the surface tension of the solvent. This is analogous to sucking liquid droplets through a straw when the container is nearly empty and the distal end of the straw is not submerged. While our visual observations were consistent with fluid transport phenomena, further investigation is warranted. If indeed E-Liquid aspiration was occurring at user-achievable flow rates, this could be a potential poisoning hazard. Al-Delaimy and Sim (
Traditional product characteristics considered for regulation include items such as E-Liquid nicotine concentration and coil resistance. However, such regulations may not achieve the desired public health outcomes. Even if ENDS manufacturers are constrained to a maximum E-Liquid nicotine mass concentration, they are able to adjust numerous product characteristics to achieve a high nicotine yield per puff including: increase the PCU Maximum Aerosolization Duration (MaxAD), decrease the coil resistance, increase the coil voltage or current, increase the coil power duty cycle, decrease the ENDS flow path resistance, or decrease the solvent saturation temperature. All of these adjusted product characteristics may result in potentially adverse unintended public health consequences. In fact, decreasing the nicotine concentration in the E-Liquid, while keeping all other product characteristics fixed, will result in a net increase in TPM exposure for a user who consumes a given mass of nicotine per day. We propose it is more effective to regulate the product characteristics of TPM (YTPM) and nicotine yield per puff (YNic = fNic × YTPM = fNic × CTPM × VPuff). In the proposed case, manufacturers have free reign to adjust numerous design parameters of their PCUs and E-Liquids, but the end-result outcome measure remains consistently regulated.
We observed variability in descriptions provided to consumers on product packaging between manufacturers. We recommend manufacturers be required to prominently disclose several characteristics of ENDS Power Control Units including: battery chemistry and capacity (mAh), designed flow rate operating range, designed maximum coil activation puff duration, and operating range of root mean square (RMS) power (watts) dissipated in a coil of a stated nominal design coil resistance (ohms). We recommend manufacturers be required to prominently disclose several characteristics of ENDS Reservoirs including: all materials present in the reservoir, solder, wick, coil, and mouthpiece, the reservoir fill volume (mL), the nominal coil resistance (ohm) and coil manufacturing variability expressed as a standard deviation (ohm). We recommend that E-Liquid manufacturers (including E-Liquid sold in disposable reservoirs and refill liquid) be required to prominently display the composition of un-puffed E-Liquid in tabular format listing the solvent components and composition (i.e., Propylene Glycol, Glycerin, water, etc.) (
No standard emissions outcome measures have previously been agreed upon. We recommend that ENDS manufacturers be required to conduct and report flow condition dependent emissions as an integral aspect of premarket regulatory approval processes. The emissions trials should be conducted over the entire range of operating envelope indicated on their product packaging and consumer information. Manufacturers should be required to report emissions outcome measures at each of several operating conditions (puff flow rate, puff duration and RMS coil power) spanning the product operating envelope. Emissions outcome measures should include at least: Total Particulate Matter (TPM) yield per puff [YTPM, (mg/puff)], TPM mass concentration [CTPM, (mg/mL)], and aerosol mass ratio of every constituent listed in the un-puffed E-Liquid [fconstituent, (mg constituent/mg TPM)]. The nicotine mass ratio was demonstrated for eight different E-Liquids herein as one example of a constituent mass ratio. Use of the emissions outcome measures (Y, C, f) has been demonstrated previously for a variety of products (
Collectively, these labeled product characteristics and emissions pre-market data serve to document the effective operating range (envelope) of an ENDS product. We propose this documentation be mandated for PMTA reporting under 81 FR 28781. The product labeling information ensures that consumers are well-informed of potential chemical exposure arising from actual product use. The proposed emission outcome measures permit regulators to assess the likelihood of potentially hazardous decomposition products which may be present in the emissions. If the E-Liquid product manufacturers are required to document 100% of the product's mass ratio content and the Reservoir product manufacturers are required to document the materials present in the ENDs reservoir assembly, then the union of these two documents result in a relatively short list of fconstituent outcome measures, which can be used to inform regulators of potential decomposition products. That is, if the summation of all fconstituent reported in the emissions adds to < 100% of the mass collected during emissions testing, there is a reasonable probability that other compounds may be present in the emissions, thus warranting further regulatory review prior to market approval.
A standard method for characterizing the operating envelope of ENDS products using four parameters (MinAF, MaxAF, MinAD, and MaxAD) has been presented and demonstrated. The study demonstrated good emissions study practices by thoroughly documenting the ENDS test specimen product characteristics, TPM yield per puff, YTPM, TPM mass concentration, CTPM, and descriptive statistics of the nominal coil resistance, Rcoil, and nicotine mass ratio, fNic, expressed as mg of nicotine per mg of TPM.
Three emissions outcome measures (Y, C, f) are recommended for adoption as standard quantities for emissions testing by manufacturers and research laboratories. Recommendations for minimum required product labeling have been proposed for ENDS power control units, reservoirs, coils and E-Liquids. Recommendations for required data to be included in premarket tobacco applications have been proposed.
Further investigation into mechanisms of E-Liquid aspiration is needed to inform potential regulations.
The original contributions presented in the study are included in the article/
EH, RR, and NE: conceptualization and funding acquisition. GD, NE, and EH: methodology. EH: software, formal analysis, writing—original draft preparation, and visualization. EH and RR: validation, resources, supervision, and project administration. NE, GD, SS, SJ, QS, BM, EH, and RR: investigation. GD, SJ, SS, BM, and EH: data curation. RR and NE: writing—review and editing. All authors contributed to the article and approved the submitted version.
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
The Supplementary Material for this article can be found online at:
Mass concentration (mg/mL) of a constituent
Electronic Nicotine Delivery System
Ratio of mass of a constituent to the mass of total particulate matter
Hazardous or Potentially Hazardous Compound
Minimum Aerosolization Flowrate
Maximum Aerosolization Flowrate
Minimum Aerosolization Duration
Maximum Aerosolization Duration
Power Control Unit
U.S. Food and Drug Administration
Total Particulate Matter
Mass yield (mg per puff) of a constituent.