<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Built Environ.</journal-id>
<journal-title>Frontiers in Built Environment</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Built Environ.</abbrev-journal-title>
<issn pub-type="epub">2297-3362</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fbuil.2020.583543</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Built Environment</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Hysteretic-Viscous Hybrid Damper System With Stopper Mechanism for Tall Buildings Under Earthquake Ground Motions of Extremely Large Amplitude</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Hashizume</surname> <given-names>Shoki</given-names></name>
<uri xlink:href="http://loop.frontiersin.org/people/1051360/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Takewaki</surname> <given-names>Izuru</given-names></name>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/166204/overview"/>
</contrib>
</contrib-group>
<aff><institution>Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University</institution>, <addr-line>Kyoto</addr-line>, <country>Japan</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Dario De Domenico, University of Messina, Italy</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Ersin Aydin, Ni&#x011F;de &#x00D6;mer Halisdemir University, Turkey; Amadeo Benvent-Climent, Polytechnic University of Madrid, Spain</p></fn>
<corresp id="c001">&#x002A;Correspondence: Izuru Takewaki, <email>takewaki@archi.kyoto-u.ac.jp</email></corresp>
<fn fn-type="other" id="fn004"><p>This article was submitted to Earthquake Engineering, a section of the journal Frontiers in Built Environment</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>29</day>
<month>09</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="collection">
<year>2020</year>
</pub-date>
<volume>6</volume>
<elocation-id>583543</elocation-id>
<history>
<date date-type="received">
<day>15</day>
<month>07</month>
<year>2020</year>
</date>
<date date-type="accepted">
<day>13</day>
<month>08</month>
<year>2020</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2020 Hashizume and Takewaki.</copyright-statement>
<copyright-year>2020</copyright-year>
<copyright-holder>Hashizume and Takewaki</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>This paper is aimed at proposing a hysteretic-viscous hybrid (HVH) damper system for tall buildings subjected to long-period pulse-type earthquake ground motions of extremely large amplitudes. The HVH system was introduced for a single-degree-of-freedom (SDOF) system in the recent paper (<xref ref-type="bibr" rid="B20">Hashizume and Takewaki, 2020</xref>). The HVH system consists of a large-stroke viscous damper and a hysteretic damper with a gap mechanism as a stopper for mitigating catastrophic damage. In the present paper, the effectiveness of the HVH system is shown for tall buildings. Pulse-type earthquake ground motions of an extremely large amplitude have been recorded in the past (for example Northridge 1994 and Kumamoto 2016). These ground motions risk causing catastrophic damage to high-rise and base-isolated buildings with a long natural period. A double impulse is used here as a substitute for pulse-type ground motions of an extremely large amplitude. Time-history response analyses are performed for an amplitude-modulated critical double impulse to reveal the effectiveness of the proposed HVH system. In addition, double impulse pushover (DIP) analysis, which was proposed by <xref ref-type="bibr" rid="B5">Akehashi and Takewaki (2019)</xref>, is conducted to reveal the critical resonant performance of elastic-plastic tall buildings together with the analysis for recorded ground motion at Kumamoto (2016). A comparison with the dual hysteretic damper (DHD) system composed of parallel-type small- and large-amplitude hysteretic dampers is also conducted to investigate the seismic performance of the proposed HVH system.</p>
</abstract>
<kwd-group>
<kwd>tall building</kwd>
<kwd>viscous damper</kwd>
<kwd>hysteretic damper</kwd>
<kwd>gap mechanism</kwd>
<kwd>stopper mechanism</kwd>
<kwd>double impulse</kwd>
<kwd>pulse-type motion</kwd>
<kwd>double impulse pushover</kwd>
</kwd-group>
<contract-sponsor id="cn001">Japan Society for the Promotion of Science<named-content content-type="fundref-id">10.13039/501100001691</named-content></contract-sponsor>
<counts>
<fig-count count="13"/>
<table-count count="2"/>
<equation-count count="18"/>
<ref-count count="48"/>
<page-count count="16"/>
<word-count count="0"/>
</counts>
</article-meta>
</front>
<body>
<sec id="S1">
<title>Introduction</title>
<p>Since the nature of natural hazards is changing rapidly, the measures for upgrading the resilience of structures need further investigation from various viewpoints (<xref ref-type="bibr" rid="B10">Bruneau et al., 2003</xref>; <xref ref-type="bibr" rid="B14">Cimellaro et al., 2010</xref>; <xref ref-type="bibr" rid="B45">Takewaki et al., 2011</xref>; <xref ref-type="bibr" rid="B34">Noroozinejad et al., 2019</xref>; <xref ref-type="bibr" rid="B44">Takewaki, 2020</xref>). The resistance to disturbances and the recovery from damages are two phases in the resilience. Although the resistance has been investigated and upgraded by advancing structural engineering technology, the recovery includes many complicated factors related to various multidisciplinary fields.</p>
<p>Up until the 1980s, it was expected that building structures should resist natural hazards by their reasonable design, i.e. allocation of stiffness and strength of their members. However, after the experience of catastrophic damages due to unpredictable natural hazards, the design principle was partially changed to the use of passive control devices for continuous use of buildings without disruption. The wide range of research on passive control can be found across versatile literature (for example, <xref ref-type="bibr" rid="B3">Aiken et al., 1993</xref>; <xref ref-type="bibr" rid="B18">Hanson, 1993</xref>; <xref ref-type="bibr" rid="B33">Nakashima et al., 1996</xref>; <xref ref-type="bibr" rid="B42">Soong and Dargush, 1997</xref>; <xref ref-type="bibr" rid="B19">Hanson and Soong, 2001</xref>; <xref ref-type="bibr" rid="B43">Takewaki, 2009</xref>; <xref ref-type="bibr" rid="B28">Lagaros et al., 2013</xref>; <xref ref-type="bibr" rid="B17">Fukumoto and Takewaki, 2017</xref>; <xref ref-type="bibr" rid="B46">Tani et al., 2017</xref>; <xref ref-type="bibr" rid="B21">Hayashi et al., 2018</xref>; <xref ref-type="bibr" rid="B30">Makita et al., 2018</xref>; <xref ref-type="bibr" rid="B27">Kondo and Takewaki, 2019</xref>; <xref ref-type="bibr" rid="B24">Kawai et al., 2020</xref>). Even in such circumstances, another kind of difficulty arose in the 2016 Kumamoto earthquake (Japan). In that earthquake, repeated severe shakings were observed within two days and a JMA (Japan Meteorological Agency) seismic intensity level of 7 (the highest level in JMA scale; approximately X-XII in Mercalli scale) was recorded in both shakings. During this earthquake, unprecedented large-amplitude ground motions (over 2.0m/s velocity amplitude compared to 0.5m/s for severe earthquake ground motions for tall buildings in Japan), called long-period pulse-type ground motions, were recorded. Since such large-amplitude ground motion is a serious event, the suppression of plastic deformations is strongly desired in view of the resistance and recovery from the viewpoint of earthquake resilience (<xref ref-type="bibr" rid="B26">Kojima and Takewaki, 2016</xref>; <xref ref-type="bibr" rid="B35">Ogawa et al., 2017</xref>).</p>
<p>Smart and optimal use of passive dampers is one of the main topics in the field of structural control and has been investigated extensively after the type of dampers is specified (see, for example, <xref ref-type="bibr" rid="B48">Xia and Hanson, 1992</xref>; <xref ref-type="bibr" rid="B22">Inoue and Kuwahara, 1998</xref>; <xref ref-type="bibr" rid="B47">Uetani et al., 2003</xref>; <xref ref-type="bibr" rid="B9">Aydin et al., 2007</xref>; <xref ref-type="bibr" rid="B43">Takewaki, 2009</xref>; <xref ref-type="bibr" rid="B29">Lavan and Levy, 2010</xref>; <xref ref-type="bibr" rid="B1">Adachi et al., 2013a</xref>, <xref ref-type="bibr" rid="B2">b</xref>; <xref ref-type="bibr" rid="B28">Lagaros et al., 2013</xref>; <xref ref-type="bibr" rid="B5">Akehashi and Takewaki, 2019</xref>; <xref ref-type="bibr" rid="B15">Domenico et al., 2019</xref>). For linear and nonlinear viscous dampers, various approaches have been developed (<xref ref-type="bibr" rid="B47">Uetani et al., 2003</xref>; <xref ref-type="bibr" rid="B7">Attard, 2007</xref>; <xref ref-type="bibr" rid="B9">Aydin et al., 2007</xref>; <xref ref-type="bibr" rid="B43">Takewaki, 2009</xref>; <xref ref-type="bibr" rid="B29">Lavan and Levy, 2010</xref>; <xref ref-type="bibr" rid="B1">Adachi et al., 2013a</xref>, <xref ref-type="bibr" rid="B2">b</xref>; <xref ref-type="bibr" rid="B5">Akehashi and Takewaki, 2019</xref>; <xref ref-type="bibr" rid="B15">Domenico et al., 2019</xref>). Since viscous dampers possess a cost problem (<xref ref-type="bibr" rid="B32">Murakami et al., 2013b</xref>), hysteretic dampers have often been used in earthquake prone countries. At the same time, simultaneous use of various types of dampers has been sought (<xref ref-type="bibr" rid="B47">Uetani et al., 2003</xref>; <xref ref-type="bibr" rid="B31">Murakami et al., 2013a</xref>,b). The nonlinear force-deformation characteristics of hysteretic dampers are similar to those of cost-effective friction-damped types (<xref ref-type="bibr" rid="B38">Pall and Marsh, 1982</xref>; <xref ref-type="bibr" rid="B8">Austin and Pister, 1985</xref>; <xref ref-type="bibr" rid="B16">Filiatrault and Cherry, 1990</xref>; <xref ref-type="bibr" rid="B12">Cherry and Filiatraut, 1993</xref>; <xref ref-type="bibr" rid="B13">Ciampi et al., 1995</xref>).</p>
<p>Compared to viscous dampers, the design of hysteretic dampers requires different kinds of treatment due to their peculiar characteristics. <xref ref-type="bibr" rid="B22">Inoue and Kuwahara (1998)</xref> picked up a single-degree-of-freedom (SDOF) model and derived a rule on the optimal hysteretic damper quantity in terms of the equivalent viscous damping (<xref ref-type="bibr" rid="B11">Caughey, 1960</xref>; <xref ref-type="bibr" rid="B23">Jacobsen, 1960</xref>). <xref ref-type="bibr" rid="B32">Murakami et al. (2013b)</xref> proposed a general and stable sensitivity-based approach applicable to various kinds of dampers including hysteretic dampers.</p>
<p>The above-mentioned peculiar characteristics in hysteretic dampers require the use of numerical optimization algorithms including time-history response analysis for response evaluation. This resulted in a tremendous amount of computational effort to reveal original properties of the optimal damper location and quantity. Compared to such conventional approaches, <xref ref-type="bibr" rid="B39">Shiomi et al. (2016)</xref> introduced an innovative design method for hysteretic dampers using an explicit expression for the maximum elastic-plastic response of a SDOF system with hysteretic dampers under &#x2018;the critical double impulse&#x2019; as a representative of near-fault ground motions (<xref ref-type="bibr" rid="B25">Kojima and Takewaki, 2015</xref>). Then an explicit optimization was performed using this explicit expression. Afterward, <xref ref-type="bibr" rid="B40">Shiomi et al. (2018)</xref> proposed an innovative control system called a &#x2018;dual hysteretic damper (DHD)&#x2019; system. Then <xref ref-type="bibr" rid="B40">Shiomi et al. (2018)</xref> developed a sensitivity-based optimal method of damper placement for multi-degree-of-freedom (MDOF) systems. Recently, <xref ref-type="bibr" rid="B20">Hashizume and Takewaki (2020)</xref> proposed another new vibration control system called a &#x2018;hysteretic-viscous hybrid (HVH)&#x2019; damper system by replacing the DSA (short-range hysteretic damper) in the DHD system with a viscous damper. They compared the response reduction performance between the DHD and the HVH for SDOF systems. However, the performance comparison for MDOF systems and various input levels of earthquake ground motions have never been conducted.</p>
<p>In this paper, the MDOF systems with the HVH system and the DHD system are subjected to the double impulse as a representative of long-period, pulse-type ground motions and a performance comparison is conducted. It should be remarked that only the critical resonant double impulse is marked as the input and the critical response properties of both damper systems can be clarified. It is further made clear that the double impulse pushover (DIP) analysis for increasing input level enables a clear description of critical response properties of both innovative damper systems.</p>
</sec>
<sec id="S2">
<title>Double Impulse as Representative of Main Part of Pulse-Type Ground Motion</title>
<p><xref ref-type="bibr" rid="B25">Kojima and Takewaki (2015)</xref> clarified that the double impulse captures the property of the main part (like a one-cycle sine wave) of a near-fault pulse-type ground motion. They found that, while the analysis of the response to the forced input, such as a sinusoidal input or earthquake ground motions, needs a combination of free and forced-vibration components even for their elastic linear responses, the double impulse only produces a free-vibration component. This helps to avoid treating the transcendental equation for resonance curves and to take full advantage of the energy balance law for obtaining the maximum response without time-history response analysis. It is often the case that the main part of a near-fault ground motion is first substituted by a one-cycle sine wave <inline-formula><mml:math id="INEQ1"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:math></inline-formula> as shown in Eq. (1) (see <xref ref-type="fig" rid="F1">Figure 1A</xref>) and then transformed into a double impulse <inline-formula><mml:math id="INEQ2"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mi>g</mml:mi></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:math></inline-formula> expressed by Eq. (2) (see <xref ref-type="fig" rid="F1">Figure 1B</xref>).</p>
<disp-formula id="S2.E1"><label>(1)</label><mml:math id="M1" display="block"><mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mrow><mml:mi>sin</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mi>t</mml:mi></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:math></disp-formula>
<disp-formula id="S2.E2"><label>(2)</label><mml:math id="M2" display="block"><mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mi>g</mml:mi></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mrow><mml:mi>V</mml:mi><mml:mi mathvariant="normal">&#x03B4;</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>-</mml:mo><mml:mrow><mml:mi>V</mml:mi><mml:mi mathvariant="normal">&#x03B4;</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>t</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:math></disp-formula>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption><p>Modeling of the main part of ground motion into double impulse, <bold>(A)</bold> Transformation of principal part of Rinaldi station FN motion (Northridge 1994) into one-cycle sinusoidal wave, <bold>(B)</bold> Re-transformation into double impulse (<xref ref-type="bibr" rid="B40">Shiomi et al., 2018</xref>).</p></caption>
<graphic xlink:href="fbuil-06-583543-g001.tif"/>
</fig>
<p>In Eqs. (1) and (2), <italic>A</italic><sub><italic>p</italic></sub>, &#x03C9;<sub><italic>p</italic></sub>, <italic>V</italic>, <italic>t</italic><sub>0</sub> are the acceleration amplitude and circular frequency of the one-cycle sine wave, the velocity amplitude of the double impulse and the time interval of the two impulses, respectively, and &#x03B4;(<italic>t</italic>) is the Dirac delta function. <xref ref-type="bibr" rid="B25">Kojima and Takewaki (2015)</xref> required the same maximum Fourier amplitude in this transformation to make their influences equivalent. This transformation is explained briefly in the following (<xref ref-type="bibr" rid="B4">Akehashi et al., 2018</xref>).</p>
<p>The Fourier transform of Eq. (2) can be expressed as</p>
<disp-formula id="S2.E3"><label>(3)</label><mml:math id="M3" display="block"><mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mi>g</mml:mi></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mi>V</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>-</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mrow><mml:mrow><mml:mtext>i</mml:mtext></mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow></mml:mrow></mml:msup></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>On the other hand, the Fourier transform of Eq. (1) can be computed by</p>
<disp-formula id="S2.E4"><label>(4)</label><mml:math id="M4" display="block"><mml:mtable><mml:mtr><mml:mtd columnalign="left"><mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:msubsup><mml:mo largeop="true" symmetric="true">&#x222B;</mml:mo><mml:mn>0</mml:mn><mml:mrow><mml:mn>2</mml:mn><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow></mml:msubsup><mml:mrow><mml:mrow><mml:mo stretchy="false">{</mml:mo><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mrow><mml:mi>sin</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mi>t</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow><mml:mo stretchy="false">}</mml:mo></mml:mrow><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mrow></mml:msup><mml:mrow><mml:mo mathvariant="italic" rspace="0pt">d</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd columnalign="left"><mml:mspace width="3.6em"/><mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msup><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:mo>-</mml:mo><mml:msup><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:mfrac><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>-</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:mrow></mml:msup></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>From Eqs. (3), (4), the Fourier amplitudes of both inputs are expressed by</p>
<disp-formula id="S2.E5"><label>(5)</label><mml:math id="M5" display="block"><mml:mrow><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mi>g</mml:mi></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>|</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mi>V</mml:mi><mml:msqrt><mml:mrow><mml:mn>2</mml:mn><mml:mo>-</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:mrow><mml:mi>cos</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:msqrt></mml:mrow></mml:mrow></mml:math></disp-formula>
<disp-formula id="S2.E6"><label>(6)</label><mml:math id="M6" display="block"><mml:mrow><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>|</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mrow><mml:mo>|</mml:mo><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mrow><mml:mi>sin</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow><mml:mrow><mml:msup><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:mo>-</mml:mo><mml:msup><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:mfrac><mml:mo>|</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>The ratio <italic>a</italic> of <italic>A</italic><sub><italic>p</italic></sub> to <italic>V</italic> as a principal index of this transformation is introduced by</p>
<disp-formula id="S2.E7"><label>(7)</label><mml:math id="M7" display="block"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mi>a</mml:mi><mml:mi>V</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>The coefficient <italic>a</italic> as a function of <italic>t</italic><sub>0</sub> can be derived as follows from Eqs. (5)&#x2013;(7) and the condition on the equivalence of the maximum Fourier amplitude <inline-formula><mml:math id="INEQ4"><mml:mrow><mml:msub><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mi>g</mml:mi></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>|</mml:mo></mml:mrow><mml:mi>max</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi/></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="INEQ5"><mml:msub><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>U</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>|</mml:mo></mml:mrow><mml:mi>max</mml:mi></mml:msub></mml:math></inline-formula>.</p>
<disp-formula id="S2.E8"><label>(8)</label><mml:math id="M8" display="block"><mml:mrow><mml:mrow><mml:mi>a</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mfrac><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mi>V</mml:mi></mml:mfrac><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mi>max</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo>|</mml:mo><mml:msqrt><mml:mrow><mml:mn>2</mml:mn><mml:mo>-</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:mrow><mml:mi>cos</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:msqrt><mml:mo>|</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mi>max</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mrow><mml:msup><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:mo>-</mml:mo><mml:msup><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:mfrac><mml:mrow><mml:mi>sin</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow><mml:mo>|</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula>
<p>In Eq. (8), it is obvious that <inline-formula><mml:math id="INEQ6"><mml:mrow><mml:mrow><mml:mi>max</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo>|</mml:mo><mml:msqrt><mml:mrow><mml:mn>2</mml:mn><mml:mo>-</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:mrow><mml:mi>cos</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mn>0</mml:mn></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:msqrt><mml:mo>|</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mn>2</mml:mn></mml:mrow></mml:math></inline-formula>. As for the denominator of Eq. (8), let us define the function <italic>f</italic>(<italic>x</italic>) = sin&#x2061;(<italic>x</italic>)/(&#x03C0;<sup>2</sup>&#x2212;<italic>x</italic><sup>2</sup>). The maximum value <italic>f</italic><sub>max</sub> of <italic>f</italic>(<italic>x</italic>) and the corresponding argument <italic>x</italic> = <italic>x</italic><sub>0</sub> can be obtained as follows (<xref ref-type="bibr" rid="B4">Akehashi et al., 2018</xref>).</p>
<disp-formula id="S2.E9"><label>(9)</label><mml:math id="M9" display="block"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mn>2.63099585</mml:mn><mml:mi mathvariant="normal">&#x2026;</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
<disp-formula id="S2.E10"><label>(10)</label><mml:math id="M10" display="block"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi>max</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi>f</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>x</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>x</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mn>0.165802809</mml:mn><mml:mi mathvariant="normal">&#x2026;</mml:mi></mml:mrow></mml:math></disp-formula>
<p>After some manipulation of Eq. (8), <italic>a</italic>(<italic>t</italic><sub>0</sub>) = 1/(&#x03C0;<italic>t</italic><sub>0</sub><italic>f</italic><sub>max</sub>) is derived.</p>
<p>Consider the ratio of the maximum velocity <italic>V</italic><sub><italic>p</italic></sub> of the one-cycle sine wave to the velocity amplitude <italic>V</italic> of the double impulse. The velocity <inline-formula><mml:math id="INEQ11"><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>.</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> of the one-cycle acceleration sine wave is expressed by</p>
<disp-formula id="S2.E11"><label>(11)</label><mml:math id="M11" display="block"><mml:mtable><mml:mtr><mml:mtd columnalign="left"><mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>.</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:msubsup><mml:mo largeop="true" symmetric="true">&#x222B;</mml:mo><mml:mn>0</mml:mn><mml:mi>t</mml:mi></mml:msubsup><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo>&#x00A8;</mml:mo></mml:mover><mml:mrow><mml:mi>g</mml:mi><mml:mi>sin</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mrow><mml:mo mathvariant="italic" rspace="0pt">d</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:msubsup><mml:mo largeop="true" symmetric="true">&#x222B;</mml:mo><mml:mn>0</mml:mn><mml:mi>t</mml:mi></mml:msubsup><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mrow><mml:mi>sin</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mi>t</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mo mathvariant="italic" rspace="0pt">d</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mrow></mml:mrow></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd columnalign="left"><mml:mspace width="3.2em"/><mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mfrac><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mfrac><mml:mrow><mml:mo>{</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>-</mml:mo><mml:mrow><mml:mi>cos</mml:mi><mml:mo>&#x2061;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mi>t</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow><mml:mo>}</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>Eq. (11) provides the maximum velocity <italic>V</italic><sub><italic>p</italic></sub> of the one-cycle sine wave.</p>
<disp-formula id="S2.E12"><label>(12)</label><mml:math id="M12" display="block"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mrow><mml:mn>2</mml:mn><mml:msub><mml:mi>A</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>The relation <italic>a</italic>(<italic>t</italic><sub>0</sub>) = 1/(&#x03C0;<italic>t</italic><sub>0</sub><italic>f</italic><sub>max</sub>) derived above and Eq. (12) lead to the relation between <italic>V</italic><sub><italic>p</italic></sub> and <italic>V</italic>.</p>
<disp-formula id="S2.E13"><label>(13)</label><mml:math id="M13" display="block"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mrow><mml:mo stretchy="false">{</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:mo>/</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msup><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:msub><mml:mi>f</mml:mi><mml:mi>max</mml:mi></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo stretchy="false">}</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>From Eqs. (10) and (13), <italic>V</italic><sub><italic>p</italic></sub>/<italic>V</italic> is expressed as</p>
<disp-formula id="S2.E14"><label>(14)</label><mml:math id="M14" display="block"><mml:mrow><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mi>V</mml:mi></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mn>2</mml:mn><mml:mo>/</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msup><mml:mi mathvariant="normal">&#x03C0;</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:msub><mml:mi>f</mml:mi><mml:mi>max</mml:mi></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mn>1.22218898</mml:mn><mml:mi mathvariant="normal">&#x2026;</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>The response correspondence between the one-cycle sine wave and the double impulse can be found in the reference (<xref ref-type="bibr" rid="B25">Kojima and Takewaki, 2015</xref>). This supports the validity of the use of the double impulse in place of the one-cycle sine wave and the near-fault ground motion.</p>
</sec>
<sec id="S3">
<title>Proposed Hysteretic-Viscous Hybrid (HVH) Damper</title>
<p>A new hysteretic-viscous hybrid (HVH) damper system was proposed in the recent paper (<xref ref-type="bibr" rid="B20">Hashizume and Takewaki, 2020</xref>). In this damper system, a gap mechanism is attached to a hysteretic damper in series (called DLA) and a viscous damper is used in parallel. The gap mechanism provides a trigger function for the hysteretic damper to delay its functioning. As a result, this hysteretic damper with a gap mechanism possesses a large-stroke performance and a function as a stopper.</p>
<p>The model of a MDOF building structure including the proposed HVH system is shown in <xref ref-type="fig" rid="F2">Figure 2</xref>. It is assumed that the building structure as a shear building model and the hysteretic damper have the elastic-perfectly plastic restoring-force characteristics. In this figure, <italic>K</italic><sub><italic>Fi</italic></sub>, <italic>k</italic><sub><italic>L</italic></sub>, <italic>c</italic><sub><italic>i</italic></sub> denote the frame stiffness in the <italic>i</italic>-th story, the stiffness ratio of the hysteretic damper (DLA) to the frame (constant through all stories), and the damping coefficient of the viscous damper in the <italic>i</italic>-th story. The fundamental natural period of the bare frame is 3.15(s) as shown later and the story stiffness distribution of the bare frame is trapezoidal (the top to bottom story stiffness ratio = 0.5). It is assumed here that the damping coefficients of the viscous dampers are proportional to the elastic stiffnesses of the main frame. Let <italic>d</italic><sub><italic>y</italic></sub>, <italic>d</italic><sub><italic>gh</italic></sub>, <italic>d</italic><sub><italic>Ly</italic></sub> denote the yield inter-story drift of the frame, the trigger displacement of DLA, and the yield displacement of DLA, respectively (constant through all stories). On the other hand, the DHD system consists of DSA for the small-amplitude range and DLA for the large-amplitude range including a gap mechanism and the stiffness ratio of DLA to DSA is denoted by &#x03B1;. With these parameters, the stiffness of DSA in the <italic>i</italic>-th story is expressed by <italic>kK</italic><sub><italic>Fi</italic></sub> and the stiffness of DLA in the <italic>i</italic>-th story is expressed by &#x03B1;<italic>kK</italic><sub><italic>Fi</italic></sub>. In addition, <italic>f</italic><sub><italic>i</italic></sub> and &#x03B4;<sub><italic>i</italic></sub> denote the story shear force in the <italic>i</italic>-th story of the frame or hysteretic dampers and the inter-story drift of the frame, respectively.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption><p>Elastic-perfectly plastic MDOF system with hysteretic-viscous hybrid (HVH) damper system, <bold>(A)</bold> Structural model with HVH damper system, <bold>(B)</bold> Story shear force-deformation relation of main frame and hysteretic damper with gap mechanism.</p></caption>
<graphic xlink:href="fbuil-06-583543-g002.tif"/>
</fig>
<p>The viscous damper is aimed at resisting the broad-amplitude range vibration and the hysteretic damper with a gap mechanism is expected to work as a stopper for the large-amplitude range vibration.</p>
</sec>
<sec id="S4">
<title>Response Reduction by Hysteretic Damper With Gap Mechanism</title>
<p>In this section, the response reduction characteristic of the MDOF system with the HVH system is presented. Especially, the influence of DLA with gap mechanism as a stopper element will be focused. The structural parameters of the main frame, the viscous damper, and the hysteretic damper (DLA) in the MDOF system with the HVH system are shown in <xref ref-type="table" rid="T1">Table 1</xref>.</p>
<table-wrap position="float" id="T1">
<label>TABLE 1</label>
<caption><p>Structural parameters of main frame, viscous damper, and hysteretic damper (HVH system).</p></caption>
<table cellspacing="5" cellpadding="5" frame="hsides" rules="groups">
<thead>
<tr>
<td valign="top" align="left" colspan="5">Main frame</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Number of stories</td>
<td valign="top" align="left">Story height</td>
<td valign="top" align="left">Floor mass</td>
<td valign="top" align="left">Fundamental-mode damping ratio</td>
<td valign="top" align="left">Yield interstory drift <italic>d</italic><sub><italic>y</italic></sub></td>
</tr>
<tr>
<td valign="top" align="left">30</td>
<td valign="top" align="left">3.5 (m)</td>
<td valign="top" align="left">4.0 &#x00D7; 10<sup>5</sup> (kg)</td>
<td valign="top" align="left">0.02</td>
<td valign="top" align="left">0.0233 (m)</td>
</tr>
<tr>
<td valign="top" align="left">Story stiffness in first story <italic>k</italic><sub><italic>F</italic>1</sub></td>
<td valign="top" align="left">Undamped fundamental natural period <italic>T</italic><sub>1</sub></td>
<td valign="top" align="left">Undamped fundamental natural circular frequency <italic>&#x03C9;</italic><sub>1</sub></td>
<td valign="top" align="left" colspan="2">Story stiffness distribution</td>
</tr>
<tr>
<td valign="top" align="left">7.2 &#x00D7; 10<sup>8</sup> (N/m)</td>
<td valign="top" align="left">3.15 (s)</td>
<td valign="top" align="left">2.00 (rad/s)</td>
<td valign="top" align="left" colspan="2">Trapezoidal (top to bottom stiffness ratio = 0.5)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5"><bold>Viscous damper</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="5">Damping ratio (Damping coefficient: proportional to main frame stiffness)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5">0.05</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5"><bold>Hysteretic damper with gap mechanism (DLA)</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Trigger displacement of DLA <italic>d</italic><sub><italic>gh</italic></sub> (=<italic>d</italic><sub><italic>y</italic></sub>)</td>
<td valign="top" align="left" colspan="2">Yield displacement of DLA <italic>d</italic><sub><italic>Ly</italic></sub></td>
<td valign="top" align="left">Stiffness ratio of DLA to main frame <italic>k</italic><sub><italic>L</italic></sub></td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">0.0233 (m)</td>
<td valign="top" align="left" colspan="2">0.0467 (m)</td>
<td valign="top" align="left">0,1,2,4</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The total story shear strength in the <italic>i</italic>th story can be expressed by <italic>Q</italic><sub><italic>yi</italic></sub> = <italic>k</italic><sub><italic>Fi</italic></sub><italic>dy</italic> + <italic>k</italic><sub><italic>L</italic></sub><italic>k</italic><sub><italic>Fi</italic></sub>(<italic>d</italic><sub><italic>Ly</italic></sub>&#x2212;<italic>d</italic><sub><italic>gh</italic></sub>) = (1 + <italic>k</italic><sub><italic>L</italic></sub>)<italic>k</italic><sub><italic>Fi</italic></sub><italic>dy</italic> and the corresponding yield shear force coefficient is expressed by <italic>c</italic><sub><italic>yi</italic></sub> = <inline-formula><mml:math id="INEQ22"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mrow><mml:mi>y</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:mrow><mml:msubsup><mml:mo largeop="true" symmetric="true">&#x2211;</mml:mo><mml:mrow><mml:mi>j</mml:mi><mml:mo>=</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn>30</mml:mn></mml:msubsup><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mi>g</mml:mi></mml:mrow></mml:mrow></mml:mrow></mml:math></inline-formula> (<italic>m</italic><sub><italic>j</italic></sub>: <italic>j</italic>th story mass, <italic>g</italic>: acceleration of gravity). In addition, the strength ratio (ratio of the damper yield strength to the story yield strength of the entire system) is expressed by <italic>k</italic><sub><italic>L</italic></sub><italic>k</italic><sub><italic>Fi</italic></sub><italic>dy</italic>/{(1 + <italic>k</italic><sub><italic>L</italic></sub>)<italic>k</italic><sub><italic>Fi</italic></sub><italic>dy</italic>} = <italic>k</italic><sub><italic>L</italic></sub>/(1 + <italic>k</italic><sub><italic>L</italic></sub>). Using the parameters in <xref ref-type="table" rid="T1">Table 1</xref>, the strength ratio becomes 0, 0.5, 0.67, 0.8 for <italic>k</italic><sub><italic>L</italic></sub> = 0,1,2,4. It is known that this strength ratio has a significant influence on the global response of building structures with displacement-dependent energy dissipation devices (<xref ref-type="bibr" rid="B22">Inoue and Kuwahara, 1998</xref>; <xref ref-type="bibr" rid="B37">Oviedo et al., 2010</xref>). However, since the present hysteretic damper system includes a gap mechanism, the previous results cannot be applied directly.</p>
<p>The nonlinear time-history response analysis was conducted by using a Newmark-&#x03B2; method (constant acceleration method). The accuracy of the analysis program was confirmed through the comparison with the general-purpose computer program, &#x2018;SNAP&#x2019; (<xref ref-type="bibr" rid="B41">SNAP, 2015</xref>).</p>
<p>The critical timing of the second impulse is obtained by conducting a time-history response analysis under the first impulse and finding the time attaining the zero value of the sum of restoring force and damping force of the damper in the first story (<xref ref-type="bibr" rid="B5">Akehashi and Takewaki, 2019</xref>).</p>
<p><xref ref-type="fig" rid="F3">Figure 3</xref> illustrates the frame ductility factor distributions of inter-story drift for various stiffness ratios <italic>k</italic><sub><italic>L</italic></sub> = 0, 1, 2, 4 of DLA to the main frame and the maximum frame ductility factor with respect to stiffness ratio <italic>k</italic><sub><italic>L</italic></sub> of DLA to the main frame in the MDOF system with the HVH system under the critical double impulse for various velocity levels <italic>V</italic> = 1.0, 1.5, 2.0 (m/s).</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption><p>Frame ductility factor distribution of inter-story drift for various stiffness ratios <italic>k</italic><sub><italic>L</italic></sub> = 0, 1, 2, 4 of the hysteretic damper (DLA) to the main frame (left) and maximum frame ductility factor with respect to <italic>k</italic><sub><italic>L</italic></sub> (right) in the MDOF system with the HVH system under critical double impulse, <bold>(A)</bold> Velocity level of double impulse <italic>V</italic> = 1.0 (m/s), <bold>(B)</bold> <italic>V</italic> = 1.5 (m/s), <bold>(C)</bold> <italic>V</italic> = 2.0 (m/s) (solid black circles indicate responses to corresponding one-cycle sine wave).</p></caption>
<graphic xlink:href="fbuil-06-583543-g003.tif"/>
</fig>
<p>It can be seen that, in the MDOF model without DLA (<italic>k</italic><sub><italic>L</italic></sub> = 0), a remarkable damage concentration can be observed in lower stories. This phenomenon is often encountered when ordinary tall building structures without special passive dampers (like a stopper system) are subjected to a pulse-type ground motion. As the value <italic>k</italic><sub><italic>L</italic></sub> becomes larger, the maximum frame ductility factor becomes smaller and its distribution approaches a nearly uniform one. It is noted that, when the input velocity is large (<xref ref-type="fig" rid="F3">Figure 3C</xref>), DLA yields and the uniformity break down a little bit. Furthermore, it can be found that DLA works in the elastic range when <italic>k</italic><sub><italic>L</italic></sub> becomes larger than an appropriate value (<italic>k</italic><sub><italic>L</italic></sub> = 1 for <italic>V</italic> = 1.0 (m/s), <italic>k</italic><sub><italic>L</italic></sub> = 2 for <italic>V</italic> = 1.5 (m/s), <italic>k</italic><sub><italic>L</italic></sub> = 6 for <italic>V</italic> = 2.0 (m/s)). In <xref ref-type="fig" rid="F3">Figure 3C</xref>, the frame ductility factor distribution to the corresponding one-cycle sine wave for <italic>k</italic><sub><italic>L</italic></sub> = 0 and <italic>V</italic> = 2.0 (m/s) is plotted with solid black circles for comparison. It can be seen that the critical double impulse is a good substitute of the corresponding one-cycle sine wave. In the input transformation, Eqs. (7)&#x2013;(14) were used.</p>
</sec>
<sec id="S5">
<title>Model Parameter Setting for HVH Damper System and DHD Damper System</title>
<p>In this section, the model parameter setting is presented for the HVH damper system and the DHD damper system.</p>
<p><xref ref-type="fig" rid="F4">Figure 4</xref> shows the MDOF systems with the HVH damper system (<xref ref-type="fig" rid="F4">Figures 4A,B</xref>) and the DHD damper system (<xref ref-type="fig" rid="F4">Figures 4C,D</xref>). The story shear force-inter-story drift relations for both models are also presented. In the later analysis, the case of <italic>d</italic><sub><italic>gh</italic></sub> = <italic>d</italic><sub><italic>y</italic></sub> and <italic>d</italic><sub><italic>Ly</italic></sub> = 2<italic>d</italic><sub><italic>y</italic></sub> is treated. <xref ref-type="fig" rid="F5">Figure 5</xref> indicates the equivalence condition of the viscous damper in the HVH system and the hysteretic damper (DSA) in the DHD system.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption><p>MDOF systems with different damper systems, <bold>(A)</bold> MDOF system with HVH system, <bold>(B)</bold> Story shear force-inter-story drift relation of MDOF system with HVH system, <bold>(C)</bold> MDOF system with DHD system, <bold>(D)</bold> Story shear force-inter-story drift relation of MDOF system with DHD system.</p></caption>
<graphic xlink:href="fbuil-06-583543-g004.tif"/>
</fig>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption><p>Equivalence condition of viscous damper in HVH system and hysteretic damper (DSA) in DHD system.</p></caption>
<graphic xlink:href="fbuil-06-583543-g005.tif"/>
</fig>
<p>Let us introduce the following equivalence condition between the damping force <italic>c</italic><sub><italic>i</italic></sub><italic>V</italic> in the viscous damper and the yielding force <italic>kK</italic><sub><italic>Fi</italic></sub><italic>d</italic><sub><italic>sy</italic></sub> of the DSA in the <italic>i</italic>-th story.</p>
<disp-formula id="S5.E15"><label>(15)</label><mml:math id="M15" display="block"><mml:mrow><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mi>V</mml:mi></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mi>k</mml:mi><mml:msub><mml:mi>K</mml:mi><mml:mrow><mml:mi>F</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>y</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>This guarantees the equivalence of the maximum forces in the HVH system (viscous damper) and the DHD system (DSA). Since it is assumed here that the damping coefficients of the viscous dampers are proportional to the elastic stiffnesses of the main frame, the following relation holds for the initial stiffness matrix of the main frame [<italic>K</italic>], the damping matrix of the viscous dampers [<italic>C</italic>], the undamped fundamental natural circular frequency &#x03C9;<sub>1</sub>, and the damping ratio <italic>h</italic><sub>1</sub> of the viscous dampers.</p>
<disp-formula id="S5.E16"><label>(16)</label><mml:math id="M16" display="block"><mml:mrow><mml:mrow><mml:mo>[</mml:mo><mml:mi>C</mml:mi><mml:mo>]</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:msub><mml:mi>h</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mfrac><mml:mrow><mml:mo>[</mml:mo><mml:mi>K</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>Eq. (16) provides the following relation.</p>
<disp-formula id="S5.E17"><label>(17)</label><mml:math id="M17" display="block"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:msub><mml:mi>h</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mfrac><mml:msub><mml:mi>K</mml:mi><mml:mrow><mml:mi>F</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>From Eqs. (15) and (17), the stiffness ratio <italic>k</italic> of DSA to the main frame can be expressed in terms of <italic>h</italic><sub>1</sub> of the viscous dampers.</p>
<disp-formula id="S5.E18"><label>(18)</label><mml:math id="M18" display="block"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:mi>V</mml:mi></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">&#x03C9;</mml:mi><mml:mn>1</mml:mn></mml:msub><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi>S</mml:mi><mml:mi>y</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:msub><mml:mi>h</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>In this paper, the damping coefficients were determined for the lowest mode. Although the lowest vibration component is predominant in elastic building structures under usual ground motions (especially in deformation components), higher mode effects may be non-negligible in elastic-plastic building structures (<xref ref-type="bibr" rid="B6">Akehashi and Takewaki, 2020</xref>).</p>
<p>For the equivalence condition, the specification of the input velocity level of the double impulse is necessary. <italic>V</italic> = 1.0(m/s) is used throughout this paper. <xref ref-type="table" rid="T2">Table 2</xref> shows the structural parameters of the main frame and two hysteretic dampers in the DHD system. By using the parameters in <xref ref-type="table" rid="T2">Table 2</xref>, the relation of Eq. (18) can be expressed as shown in <xref ref-type="fig" rid="F6">Figure 6A</xref>. It should be noted that <xref ref-type="table" rid="T1">Table 1</xref> was only used for the analysis in <xref ref-type="fig" rid="F3">Figure 3</xref> and the stiffness of DLA in the DHD system shown in <xref ref-type="table" rid="T2">Table 2</xref> is used in the later analysis of the HVH system. Therefore, the DLA is the same in the HVH and the DHD.</p>
<table-wrap position="float" id="T2">
<label>TABLE 2</label>
<caption><p>Structural parameters of main frame and two hysteretic dampers (DHD system).</p></caption>
<table cellspacing="5" cellpadding="5" frame="hsides" rules="groups">
<thead>
<tr>
<td valign="top" align="left" colspan="5">Main frame</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Number of stories</td>
<td valign="top" align="left">Story height</td>
<td valign="top" align="left">Floor mass</td>
<td valign="top" align="left">Fundamental-mode damping ratio</td>
<td valign="top" align="left">Yield interstory drift <italic>d</italic><sub><italic>y</italic></sub></td>
</tr>
<tr>
<td valign="top" align="left">30</td>
<td valign="top" align="left">3.5 (m)</td>
<td valign="top" align="left">4.0x10<sup>5</sup> (kg)</td>
<td valign="top" align="left">0.02</td>
<td valign="top" align="left">0.0233 (m)</td>
</tr>
<tr>
<td valign="top" align="left">Story stiffness in first story <italic>k</italic><sub><italic>F</italic>1</sub></td>
<td valign="top" align="left">Undamped fundamental natural period <italic>T</italic><sub>1</sub></td>
<td valign="top" align="left">Undamped fundamental natural circular frequency <italic>&#x03C9;</italic><sub>1</sub></td>
<td valign="top" align="left" colspan="2">Story stiffness distribution</td>
</tr>
<tr>
<td valign="top" align="left">7.2x10<sup>8</sup> (N/m)</td>
<td valign="top" align="left">3.15 (s)</td>
<td valign="top" align="left">2.00 (rad/s)</td>
<td valign="top" align="left" colspan="2">Trapezoidal (top to bottom stiffness ratio = 0.5)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5"><bold>Hysteretic damper for short range (DSA)</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="5">Yield displacement of DSA <italic>d</italic><sub><italic>Sy</italic></sub> (=0.7<italic>d</italic><sub><italic>y</italic></sub>)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5">0.0163 (m)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5"><bold>Hysteretic damper with gap mechanism (DLA)</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Trigger displacement of DLA <italic>d</italic><sub><italic>gh</italic></sub> (=<italic>d</italic><sub><italic>y</italic></sub>)</td>
<td valign="top" align="left" colspan="2">Yield displacement of DLA <italic>d</italic><sub><italic>Ly</italic></sub></td>
<td valign="top" align="left">Stiffness ratio of DLA to DSA &#x03B1;</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">0.0233 (m)</td>
<td valign="top" align="left" colspan="2">0.0467 (m)</td>
<td valign="top" align="left">2</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption><p>Damper properties, <bold>(A)</bold> Stiffness ratio <italic>k</italic> of DSA in DHD to main frame with respect to damping ratio <italic>h</italic><sub>1</sub> of viscous damper in HVH (using Eq. (18) for <italic>V</italic> = 1.0(m/s)), <bold>(B)</bold> Damping coefficient <italic>c</italic><sub><italic>i</italic></sub> of viscous dampers in HVH for several damping ratios.</p></caption>
<graphic xlink:href="fbuil-06-583543-g006.tif"/>
</fig>
</sec>
<sec id="S6">
<title>Response Comparison Between MDOF System With HVH System and MDOF System With DHD System</title>
<p>In this section, the responses of the MDOF system with the HVH system and the MDOF system with the DHD system are compared.</p>
<p><xref ref-type="fig" rid="F7">Figure 7</xref> shows the frame ductility factor distributions of inter-story drift in the MDOF system with the HVH system for various damping levels of viscous dampers <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 and the MDOF system with the DHD system of the equivalent damper quantity of DSA (using Eq. (18)) under the critical double impulse with <italic>V</italic> = 2.0 (m/s). The damping coefficients <italic>c</italic><sub><italic>i</italic></sub> of viscous dampers in the HVH system are shown in <xref ref-type="fig" rid="F6">Figure 6B</xref>. It can be observed that, in the case of <italic>h</italic><sub>1</sub> = 0.01,0.02, the response reduction effect is larger in the DHD system. On the other hand, as the viscous damper quantity in the HVH system becomes larger, the response reduction effect is larger in the HVH system. However, the response reduction effects of both damper systems do not differ so much.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption><p>Frame ductility factor distribution of inter-story drift in MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (18)) under critical double impulse with <italic>V</italic> = 2.0 (m/s).</p></caption>
<graphic xlink:href="fbuil-06-583543-g007.tif"/>
</fig>
<p>On the other hand, <xref ref-type="fig" rid="F8">Figure 8</xref> presents the time histories of the 15th-story inter-story drifts of the MDOF system with the HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and the MDOF system with the DHD system of the equivalent damper quantity of DSA (using Eq. (18)) under the critical double impulse with <italic>V</italic> = 2.0 (m/s). Furthermore, <xref ref-type="fig" rid="F9">Figure 9</xref> illustrates similar time histories for the 30th-story inter-story drifts. It can be seen that, although the 15th-story inter-story drifts of both damper systems (HVH and DHD) do not differ so much in the case of <italic>h</italic><sub>1</sub> = 0.05,0.1 (<xref ref-type="fig" rid="F7">Figure 7</xref>), the MDOF system with the DHD system exhibits a larger residual deformation. Since DLA does not go into the plastic range, this residual deformation seems to result from the plastic deformation of DSA. In addition, in the case of <italic>h</italic><sub>1</sub> = 0.01,0.02, the 15th-story inter-story drifts of both damper systems (HVH and DHD) cause large residual deformations. Since DLA goes into the plastic range in both HVH and DHD systems, this residual deformation seems to result from the plastic deformation of DLA. On the other hand, the 30th-story inter-story drifts of both damper systems (HVH and DHD) do not cause so much large residual deformation. This is because the maximum 30th-story inter-story drifts of both damper systems (HVH and DHD) are not so large and both models almost remain in the elastic range.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption><p>Time history of 15th-story inter-story drift of MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (18)) under critical double impulse with <italic>V</italic> = 2.0 (m/s).</p></caption>
<graphic xlink:href="fbuil-06-583543-g008.tif"/>
</fig>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption><p>Time history of 30th-story inter-story drift of MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (18)) under critical double impulse with <italic>V</italic> = 2.0 (m/s).</p></caption>
<graphic xlink:href="fbuil-06-583543-g009.tif"/>
</fig>
</sec>
<sec id="S7">
<title>Double Impulse Pushover (DIP) Analysis</title>
<p>In this section, the characteristic of damage concentration for increasing input level is clarified for both the MDOF system with the HVH system and the MDOF system with the DHD system. This analysis is completed by using the double impulse pushover (DIP) analysis proposed by <xref ref-type="bibr" rid="B5">Akehashi and Takewaki (2019)</xref>. In the DIP analysis, the critical timing of the second impulse is computed for a specified input level by conducting a time-history response analysis under the first impulse and finding the time attaining the zero value of the sum of restoring force and damping force of the damper in the first story. Then, this procedure is repeated for the increasing input velocity level (<xref ref-type="bibr" rid="B5">Akehashi and Takewaki, 2019</xref>).</p>
<p><xref ref-type="fig" rid="F10">Figure 10</xref> shows the results of the DIP analysis (<italic>V</italic> = 0.3&#x2013;3.0 (m/s) with increment 0.3 (m/s)) for the MDOF system with the HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and the MDOF system with DHD system of the equivalent damper quantity of DSA (using Eq. (18) for <italic>V</italic> = 1.0 (m/s)). It can be observed that, in the case of <italic>h</italic><sub>1</sub> = 0.01, as the input velocity level increases, the damage concentration occurs in the middle stories in both systems of HVH and DHD. On the other hand, in the case of <italic>h</italic><sub>1</sub> = 0.02, a different phenomenon occurs as the input velocity level increases. While the damage concentration occurs in the middle stories for the HVH system, that occurs in the lower stories for the DHD system. When the fundamental damping ratio attains <italic>h</italic><sub>1</sub> = 0.1,0.2,0.3, the frame ductility factor distribution exhibits almost uniform distribution in both damper systems even for the input velocity level <italic>V</italic> = 3.0(m/s) and DLA almost remains in the elastic range. Since the DIP analysis only seeks for the critical resonant case, it is appropriate for clarifying the system&#x2019;s critical performance for the increasing input level.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption><p>Double impulse pushover (DIP) analysis (<italic>V</italic> = 0.3&#x2013;3.0 (m/s) with increment 0.3 (m/s)) for MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (18) for <italic>V</italic> = 1.0 (m/s)) (&#x2212;HVH; &#x2212;DHD).</p></caption>
<graphic xlink:href="fbuil-06-583543-g010.tif"/>
</fig>
<p><xref ref-type="fig" rid="F11">Figure 11</xref> presents the maximum frame ductility factor with respect to the input velocity level of the double impulse for the MDOF system with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and the MDOF system with DHD system of the equivalent damper quantity of DSA (using Eq. (18) for <italic>V</italic> = 1.0(m/s)). It can be understood that, in the case of <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05, the DHD damper system exhibits a higher response reduction performance for a wide range of input level. On the other hand, in the case of <italic>h</italic><sub>1</sub> = 0.1,0.2,0.3, the HVH damper system is superior to the DHD damper system in the larger input velocity range. However, its difference is quite small.</p>
<fig id="F11" position="float">
<label>FIGURE 11</label>
<caption><p>Maximum frame ductility factor with respect to input velocity level of double impulse for MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (18) for <italic>V</italic> = 1.0 (m/s)).</p></caption>
<graphic xlink:href="fbuil-06-583543-g011.tif"/>
</fig>
</sec>
<sec id="S8">
<title>Response Comparison of MDOF Building Model Including HVH System With Building Model Including DHD System Under Recorded Ground Motion of Extremely Large Amplitude</title>
<p>The effectiveness of the HVH system and the DHD system in the MDOF building model under a recorded long-period pulse-type ground motion of extremely large amplitude is shown in this section. <xref ref-type="fig" rid="F12">Figures 12A,B</xref> show a ground acceleration time history and the corresponding velocity time history of the JMA Nishiharamura-Komori (EW) wave during the Kumamoto earthquake in 2016. This ground motion is known as a long-period pulse-type ground motion of extremely large velocity amplitude. While the maximum velocity level of severe earthquake ground motions in the code for tall buildings in Japan is 0.5 m/s, the recorded one in the Kumamoto earthquake is over 2.0 m/s. <xref ref-type="fig" rid="F12">Figures 12C&#x2013;F</xref> show the displacement, velocity, acceleration response spectra, and the input energy spectrum (<xref ref-type="bibr" rid="B36">Ordaz et al., 2003</xref>). It can be understood that this ground motion has a large velocity response around 0.7, 3.0(s) and the intensity around 3.0(s) is expected to influence the response of the present MDOF model with the HVH of the fundamental natural period 3.15(s). Furthermore, it is noted that, since the MDOF model with the DHD possesses DSA, its fundamental natural period is shorter than 3.15(s). It should also be remarked that this recorded ground motion is not necessarily critical to the MDOF systems with the HVH system and with the DHD system because both models will experience the large plastic response.</p>
<fig id="F12" position="float">
<label>FIGURE 12</label>
<caption><p>Long-period pulse-type ground motion of extremely large amplitude, <bold>(A)</bold> Ground acceleration of JMA Nishiharamura-Komori (EW) wave, <bold>(B)</bold> Ground velocity of JMA Nishiharamura-Komori (EW) wave, <bold>(C)</bold> Displacement response spectrum, <bold>(D)</bold> Velocity response spectrum, <bold>(E)</bold> Acceleration response spectrum (<xref ref-type="bibr" rid="B20">Hashizume and Takewaki, 2020</xref>), and <bold>(F)</bold> Input energy spectrum.</p></caption>
<graphic xlink:href="fbuil-06-583543-g012.tif"/>
</fig>
<p><xref ref-type="fig" rid="F13">Figure 13</xref> indicates the comparison of frame ductility factor distributions of inter-story drift in the MDOF system with the HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and the MDOF system with the DHD system of the equivalent damper quantity of DSA (using Eq. (18) for <italic>V</italic> = 1.0(m/s)) under the JMA Nishiharamura-Komori (EW). It can be observed that the DHD system exhibits a high response reduction performance for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1 of viscous dampers under this recorded ground motion. More specifically, when the damping levels of viscous dampers are <italic>h</italic><sub>1</sub> = 0.01,0.02, the frame ductility factor exceeds 2 and DLA goes into the plastic range. In addition, some damage concentration can be observed in lower and middle stories. On the other hand, when the damping levels of viscous dampers are <italic>h</italic><sub>1</sub> = 0.05,0.1,0.2,0.3, the frame ductility factor does not exceed 2 approximately and DLA remains in the elastic range. In addition, no damage concentration is observed. It is important to note again that the MDOF system with the DHD system has a fundamental natural period shorter than 3.15(s) of the bare frame (and also the MDOF system with HVH system) due to the existence of DSA. Judging from the response spectra in <xref ref-type="fig" rid="F12">Figure 12</xref> (displacement and velocity response spectra decrease when the natural period becomes shorter than 3.0(s)), this change of the fundamental natural period brought a difference in the frame ductility factors in <xref ref-type="fig" rid="F13">Figure 13</xref>. Although some attempts to scale the ground motion for respective control systems (HVH and DHD) can be considered in the comparison, the simultaneous modification in the amplitude and time scales may be meaningful from the viewpoint of resonance. For this purpose, it seems that the DIP analysis shown in <xref ref-type="fig" rid="F10">Figures 10</xref>, <xref ref-type="fig" rid="F11">11</xref> is superior to the analysis for the recorded ground motion because only the critical resonant case is sought depending on the level of plastic response and the intrinsic characteristic on the performance of damper systems can be captured in a reliable and reasonable way.</p>
<fig id="F13" position="float">
<label>FIGURE 13</label>
<caption><p>Frame ductility factor distribution of inter-story drift in MDOF systems with HVH system for various damping levels <italic>h</italic><sub>1</sub> = 0.01,0.02,0.05,0.1,0.2,0.3 of viscous dampers and with DHD system of equivalent damper quantity of DSA (using Eq. (4) for <italic>V</italic> = 1.0 (m/s)) under JMA Nishiharamura-Komori (EW) wave.</p></caption>
<graphic xlink:href="fbuil-06-583543-g013.tif"/>
</fig>
</sec>
<sec id="S9">
<title>Conclusion</title>
<p>The viscous-hysteretic hybrid (HVH) damper system proposed in the previous paper for a single-degree-of-freedom (SDOF) system was extended to a multi-degree-of-freedom (MDOF) system subjected to pulse-type earthquake ground motions of an extremely large amplitude. The HVH system consists of a viscous damper and a hysteretic damper with a gap mechanism as a stopper. The following conclusions were derived.</p>
<list list-type="simple">
<list-item>
<label>1.</label>
<p>Since the pulse-type earthquake ground motion of extremely large amplitude causes a complicated catastrophic effect on tall buildings, the treatment of tall buildings as MDOF systems is inevitable for a reliable analysis of its effect. The effectiveness of the HVH system in tall buildings was analyzed and demonstrated.</p>
</list-item>
<list-item>
<label>2.</label>
<p>A double impulse was used as a substitute for pulse-type ground motions of extremely large amplitude. Time-history response analyses were performed for an amplitude modulated critical double impulse to investigate the effectiveness of the proposed HVH system. It was demonstrated that the HVH system is effective for various levels of the double impulse which causes a large plastic deformation. The hysteretic damper with a gap mechanism as a stopper element plays an important role in the effective reduction of concentrated plastic deformations.</p>
</list-item>
<list-item>
<label>3.</label>
<p>The double impulse pushover (DIP) analysis, which was proposed by <xref ref-type="bibr" rid="B5">Akehashi and Takewaki (2019)</xref>, was conducted and revealed the critical resonant performance of elastic-plastic tall buildings. It was demonstrated that the HVH system is also effective for gradually increasing critical double impulse. In addition, an analysis to a recorded ground motion at Kumamoto (2016) was conducted. It was clarified that the HVH system also has a good performance for a recorded ground motion of extremely large amplitude.</p>
</list-item>
<list-item>
<label>4.</label>
<p>The comparison with the formerly proposed dual hysteretic damper (DHD) system composed of parallel-type small and large-amplitude hysteretic dampers was also conducted. The large-amplitude hysteretic damper includes a gap mechanism as in the HVH system. It was shown that the performance of the HVH system is almost equivalent to the DHD system except in a few examples and the small residual deformation of the HVH system is an advantageous feature.</p>
</list-item>
</list>
</sec>
<sec id="S10">
<title>Data Availability Statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="S11">
<title>Author Contributions</title>
<p>SH formulated the problem, conducted the computation, and wrote the manuscript. IT supervised the research and wrote the manuscript. Both authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="conf1">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="financial-disclosure">
<p><bold>Funding.</bold> Part of the present work is supported by the Grant-in-Aid for Scientific Research (KAKENHI) of Japan Society for the Promotion of Science (No. 18H01584). This support is greatly appreciated.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="B1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Adachi</surname> <given-names>F.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2013a</year>). <article-title>Importance of interstory velocity on optimal alongheight allocation of viscous oil dampers in super highrise buildings.</article-title> <source><italic>Eng. Struct</italic></source> <volume>56</volume> <fpage>489</fpage>&#x2013;<lpage>500</lpage>. <pub-id pub-id-type="doi">10.1016/j.engstruct.2013.05.036</pub-id></citation></ref>
<ref id="B2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Adachi</surname> <given-names>F.</given-names></name> <name><surname>Yoshitomi</surname> <given-names>S.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2013b</year>). <article-title>Nonlinear optimal oil damper design in seismically controlled multi-story building frame.</article-title> <source><italic>Soil Dyn. Earthq. Eng.</italic></source> <volume>44</volume> <fpage>1</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1016/j.soildyn.2012.08.010</pub-id></citation></ref>
<ref id="B3"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aiken</surname> <given-names>I. D.</given-names></name> <name><surname>Nims</surname> <given-names>D. K.</given-names></name> <name><surname>Whittaker</surname> <given-names>A. S.</given-names></name> <name><surname>Kelly</surname> <given-names>J. M.</given-names></name></person-group> (<year>1993</year>). <article-title>Testing of passive energy dissipation systems.</article-title> <source><italic>Earthq. Spectra</italic></source> <volume>9</volume> <fpage>335</fpage>&#x2013;<lpage>370</lpage>. <pub-id pub-id-type="doi">10.1193/1.1585720</pub-id></citation></ref>
<ref id="B4"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Akehashi</surname> <given-names>H.</given-names></name> <name><surname>Kojima</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2018</year>). <article-title>Critical response of SDOF damped bilinear hysteretic system under double impulse as substitute for near-fault ground motion.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>4</volume>:<issue>5</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2018.00005</pub-id></citation></ref>
<ref id="B5"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Akehashi</surname> <given-names>H.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2019</year>). <article-title>Optimal viscous damper placement for elastic-plastic MDOF structures under critical double impulse.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>5</volume>:<issue>20</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2019.00020</pub-id></citation></ref>
<ref id="B6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Akehashi</surname> <given-names>H.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2020</year>). <article-title>Comparative investigation on optimal viscous damper placement for elastic-plastic MDOF structures: transfer function amplitude or double impulse.</article-title> <source><italic>Soil Dyn. Earthq. Eng.</italic></source> <volume>130</volume>:<issue>105987</issue>. <pub-id pub-id-type="doi">10.1016/j.soildyn.2019.105987</pub-id></citation></ref>
<ref id="B7"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Attard</surname> <given-names>T. L.</given-names></name></person-group> (<year>2007</year>). <article-title>Controlling all interstory displacements in highly nonlinear steel buildings using optimal viscous damping.</article-title> <source><italic>J. Struct. Eng. ASCE</italic></source> <volume>133</volume> <fpage>1331</fpage>&#x2013;<lpage>1340</lpage>. <pub-id pub-id-type="doi">10.1061/(asce)0733-9445(2007)133:9(1331)</pub-id></citation></ref>
<ref id="B8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Austin</surname> <given-names>M. A.</given-names></name> <name><surname>Pister</surname> <given-names>K. S.</given-names></name></person-group> (<year>1985</year>). <article-title>Design of seismic-resistant friction-braced frames.</article-title> <source><italic>J. Struct. Eng. ASCE</italic></source> <volume>111</volume> <fpage>2751</fpage>&#x2013;<lpage>2769</lpage>. <pub-id pub-id-type="doi">10.1061/(asce)0733-9445(1985)111:12(2751)</pub-id></citation></ref>
<ref id="B9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aydin</surname> <given-names>E.</given-names></name> <name><surname>Boduroglub</surname> <given-names>M. H.</given-names></name> <name><surname>Guney</surname> <given-names>D.</given-names></name></person-group> (<year>2007</year>). <article-title>Optimal damper distribution for seismic rehabilitation of planar building structures.</article-title> <source><italic>Eng. Struct.</italic></source> <volume>29</volume> <fpage>176</fpage>&#x2013;<lpage>185</lpage>. <pub-id pub-id-type="doi">10.1016/j.engstruct.2006.04.016</pub-id></citation></ref>
<ref id="B10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bruneau</surname> <given-names>M.</given-names></name> <name><surname>Chang</surname> <given-names>S. E.</given-names></name> <name><surname>Eguchi</surname> <given-names>R. T.</given-names></name> <name><surname>Lee</surname> <given-names>G. C.</given-names></name> <name><surname>O&#x2019;Rourke</surname> <given-names>T. D.</given-names></name> <name><surname>Reinhorn</surname> <given-names>A. M.</given-names></name><etal/></person-group> (<year>2003</year>). <article-title>A framework to quantitatively assess andenhance the seismic resilience of communities.</article-title> <source><italic>Earthq. Spectra</italic></source> <volume>19</volume> <fpage>733</fpage>&#x2013;<lpage>752</lpage>. <pub-id pub-id-type="doi">10.1193/1.1623497</pub-id></citation></ref>
<ref id="B11"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Caughey</surname> <given-names>T. K.</given-names></name></person-group> (<year>1960</year>). <article-title>Sinusoidal excitation of a system with bilinear hysteresis.</article-title> <source><italic>J. Appl. Mech.</italic></source> <volume>27</volume> <fpage>640</fpage>&#x2013;<lpage>643</lpage>. <pub-id pub-id-type="doi">10.1115/1.3644075</pub-id></citation></ref>
<ref id="B12"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cherry</surname> <given-names>S.</given-names></name> <name><surname>Filiatraut</surname> <given-names>A.</given-names></name></person-group> (<year>1993</year>). <article-title>Seismic response control of buildings using friction damper.</article-title> <source><italic>Earthq. Spectra</italic></source> <volume>9</volume> <fpage>447</fpage>&#x2013;<lpage>466</lpage>. <pub-id pub-id-type="doi">10.1193/1.1585724</pub-id></citation></ref>
<ref id="B13"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ciampi</surname> <given-names>V.</given-names></name> <name><surname>Angelis</surname> <given-names>M. D.</given-names></name> <name><surname>Paolacci</surname> <given-names>F.</given-names></name></person-group> (<year>1995</year>). <article-title>Design of yielding or friction-based dissipative bracings for seismic protection of buildings.</article-title> <source><italic>Eng. Struct.</italic></source> <volume>17</volume> <fpage>381</fpage>&#x2013;<lpage>391</lpage>. <pub-id pub-id-type="doi">10.1016/0141-0296(95)00021-x</pub-id></citation></ref>
<ref id="B14"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cimellaro</surname> <given-names>G.</given-names></name> <name><surname>Reinhorn</surname> <given-names>A.</given-names></name> <name><surname>Bruneau</surname> <given-names>M.</given-names></name></person-group> (<year>2010</year>). <article-title>Framework for analytical quantification of disaster resilience.</article-title> <source><italic>Eng. Struct.</italic></source> <volume>32</volume> <fpage>3639</fpage>&#x2013;<lpage>3649</lpage>. <pub-id pub-id-type="doi">10.1016/j.engstruct.2010.08.008</pub-id></citation></ref>
<ref id="B15"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Domenico</surname> <given-names>D. D.</given-names></name> <name><surname>Ricciardi</surname> <given-names>G.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2019</year>). <article-title>Design strategies of viscous dampers for seismic protection of building structures: a review.</article-title> <source><italic>Soil Dyn. Earthq. Eng.</italic></source> <volume>118</volume> <fpage>144</fpage>&#x2013;<lpage>165</lpage>. <pub-id pub-id-type="doi">10.1016/j.soildyn.2018.12.024</pub-id></citation></ref>
<ref id="B16"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Filiatrault</surname> <given-names>A.</given-names></name> <name><surname>Cherry</surname> <given-names>S.</given-names></name></person-group> (<year>1990</year>). <article-title>Seismic design spectra for friction-damped structure.</article-title> <source><italic>J. Struct. Eng. ASCE</italic></source> <volume>116</volume> <fpage>1334</fpage>&#x2013;<lpage>1355</lpage>. <pub-id pub-id-type="doi">10.1061/(asce)0733-9445(1990)116:5(1334)</pub-id></citation></ref>
<ref id="B17"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fukumoto</surname> <given-names>Y.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2017</year>). <article-title>Dual control high-rise building for robuster earthquake performance.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>3</volume>:<issue>12</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2017.00012</pub-id></citation></ref>
<ref id="B18"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hanson</surname> <given-names>R. D.</given-names></name></person-group> (<year>1993</year>). <article-title>Supplemental damping for improved seismic performance.</article-title> <source><italic>Earthq. Spectra</italic></source> <volume>9</volume> <fpage>319</fpage>&#x2013;<lpage>334</lpage>. <pub-id pub-id-type="doi">10.1193/1.1585719</pub-id></citation></ref>
<ref id="B19"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hanson</surname> <given-names>R. D.</given-names></name> <name><surname>Soong</surname> <given-names>T. T.</given-names></name></person-group> (<year>2001</year>). <source><italic>Seismic Design With Supplemental Energy Dissipation Devices.</italic></source> <publisher-loc>Oakland, CA</publisher-loc>: <publisher-name>EERI</publisher-name>.</citation></ref>
<ref id="B20"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hashizume</surname> <given-names>S.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2020</year>). <article-title>Hysteretic-viscous hybrid damper system for long-period pulse-type earthquake ground motions of large amplitude.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>6</volume>:<issue>62</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2020.00062</pub-id></citation></ref>
<ref id="B21"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hayashi</surname> <given-names>K.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2018</year>). <article-title>A simple response evaluation method for base-isolation building-connection hybrid structural system under long-period and long-duration ground motion.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>4</volume>:<issue>2</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2018.00002</pub-id></citation></ref>
<ref id="B22"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Inoue</surname> <given-names>K.</given-names></name> <name><surname>Kuwahara</surname> <given-names>S.</given-names></name></person-group> (<year>1998</year>). <article-title>Optimum strength ratio of hysteretic damper.</article-title> <source><italic>Earthq. Eng. Struct. Dyn.</italic></source> <volume>27</volume> <fpage>577</fpage>&#x2013;<lpage>588</lpage>. <pub-id pub-id-type="doi">10.1002/(sici)1096-9845(199806)27:6&#x003C;577::aid-eqe743&#x003E;3.0.co;2-u</pub-id></citation></ref>
<ref id="B23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jacobsen</surname> <given-names>L. S.</given-names></name></person-group> (<year>1960</year>). <source><italic>Damping in Composite Structures.</italic></source> <publisher-loc>Tokyo</publisher-loc>: <publisher-name>WCEE</publisher-name>, <fpage>1029</fpage>&#x2013;<lpage>1044</lpage>.</citation></ref>
<ref id="B24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kawai</surname> <given-names>A.</given-names></name> <name><surname>Maeda</surname> <given-names>T.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2020</year>). <article-title>Smart seismic control system for high-rise buildings using large-stroke viscous dampers through connection to strong-back core frame.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>6</volume>:<issue>29</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2020.00029</pub-id></citation></ref>
<ref id="B25"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kojima</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2015</year>). <article-title>Critical earthquake response of elastic-plastic structures under near-fault ground motions (Part 1: Fling-step input).</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>1</volume>:<issue>12</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2015.00012</pub-id></citation></ref>
<ref id="B26"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kojima</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2016</year>). <article-title>A simple evaluation method of seismic resistance of residential house under two consecutive severe ground motions with intensity 7.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>2</volume>:<issue>15</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2016.00015</pub-id></citation></ref>
<ref id="B27"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kondo</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2019</year>). <article-title>Simultaneous approach to critical fault rupture slip distribution and optimal damper placement for resilient building design.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>5</volume>:<issue>126</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2019.00126</pub-id></citation></ref>
<ref id="B28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lagaros</surname> <given-names>N.</given-names></name> <name><surname>Plevris</surname> <given-names>V.</given-names></name> <name><surname>Mitropoulou</surname> <given-names>C. C.</given-names></name></person-group> (<role>eds</role>) (<year>2013</year>). <source><italic>Design Optimization of Active and Passive Structural Control Systems.</italic></source> <publisher-loc>Pennsylvania</publisher-loc>: <publisher-name>IGI Global</publisher-name>.</citation></ref>
<ref id="B29"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lavan</surname> <given-names>O.</given-names></name> <name><surname>Levy</surname> <given-names>R.</given-names></name></person-group> (<year>2010</year>). <article-title>Performance based optimal seismic retrofitting of yielding plane frames using added viscous damping.</article-title> <source><italic>Earthq. Struct.</italic></source> <volume>1</volume> <fpage>307</fpage>&#x2013;<lpage>326</lpage>. <pub-id pub-id-type="doi">10.12989/eas.2010.1.3.307</pub-id></citation></ref>
<ref id="B30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Makita</surname> <given-names>K.</given-names></name> <name><surname>Murase</surname> <given-names>M.</given-names></name> <name><surname>Kondo</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2018</year>). <article-title>Robustness evaluation of base- isolation building-connection hybrid controlled building structures considering uncertainties in deep ground.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>4</volume>:<issue>16</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2018.00016</pub-id></citation></ref>
<ref id="B31"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Murakami</surname> <given-names>Y.</given-names></name> <name><surname>Noshi</surname> <given-names>K.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2013a</year>). <article-title>Optimal placement of hysteretic dampers via adaptive smoothing algorithm.</article-title> <source><italic>ICEAS</italic></source> <volume>13</volume> <fpage>1821</fpage>&#x2013;<lpage>1835</lpage>.</citation></ref>
<ref id="B32"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Murakami</surname> <given-names>Y.</given-names></name> <name><surname>Noshi</surname> <given-names>K.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2013b</year>). <article-title>Simultaneous optimal damper placement using oil, hysteretic and inertial mass dampers.</article-title> <source><italic>Earthq. Struct.</italic></source> <volume>5</volume> <fpage>261</fpage>&#x2013;<lpage>276</lpage>. <pub-id pub-id-type="doi">10.12989/eas.2013.5.3.261</pub-id></citation></ref>
<ref id="B33"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nakashima</surname> <given-names>M.</given-names></name> <name><surname>Saburi</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>B.</given-names></name></person-group> (<year>1996</year>). <article-title>Energy input and dissipation behaviour of structures with hysteretic dampers.</article-title> <source><italic>Earthq. Eng. Struct. Dyn.</italic></source> <volume>25</volume> <fpage>483</fpage>&#x2013;<lpage>496</lpage>. <pub-id pub-id-type="doi">10.1002/(sici)1096-9845(199605)25:5&#x003C;483::aid-eqe564&#x003E;3.0.co;2-k</pub-id></citation></ref>
<ref id="B34"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Noroozinejad</surname> <given-names>E.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name> <name><surname>Yang</surname> <given-names>T. Y.</given-names></name> <name><surname>Astaneh-Asl</surname> <given-names>A.</given-names></name> <name><surname>Gardoni</surname> <given-names>P.</given-names></name></person-group> (<role>eds</role>) (<year>2019</year>). <source><italic>Resilient Structures and Infrastructures.</italic></source> <publisher-loc>Berlin</publisher-loc>: <publisher-name>Springer</publisher-name>.</citation></ref>
<ref id="B35"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ogawa</surname> <given-names>Y.</given-names></name> <name><surname>Kojima</surname> <given-names>K.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2017</year>). <article-title>General evaluation method of seismic resistance of residential house under multiple consecutive severe ground motions with high intensity.</article-title> <source><italic>Int. J. Earthq. Impact Eng.</italic></source> <volume>2</volume> <fpage>158</fpage>&#x2013;<lpage>174</lpage>. <pub-id pub-id-type="doi">10.1504/ijeie.2017.10010044</pub-id></citation></ref>
<ref id="B36"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ordaz</surname> <given-names>M.</given-names></name> <name><surname>Huerta</surname> <given-names>B.</given-names></name> <name><surname>Reinoso</surname> <given-names>E.</given-names></name></person-group> (<year>2003</year>). <article-title>&#x2018;Exact computation of input-energy spectra from Fourier amplitude spectra.</article-title> <source><italic>Earthq. Eng. Struct. Dyn.</italic></source> <volume>32</volume> <fpage>597</fpage>&#x2013;<lpage>605</lpage>. <pub-id pub-id-type="doi">10.1002/eqe.240</pub-id></citation></ref>
<ref id="B37"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oviedo</surname> <given-names>A. J. A.</given-names></name> <name><surname>Midorikawa</surname> <given-names>M.</given-names></name> <name><surname>Asari</surname> <given-names>T.</given-names></name></person-group> (<year>2010</year>). <article-title>Earthquake response of ten-story story-driftcontrolled reinforced concrete frames with hysteretic dampers.</article-title> <source><italic>Eng. Struct.</italic></source> <volume>32</volume> <fpage>1735</fpage>&#x2013;<lpage>1746</lpage>. <pub-id pub-id-type="doi">10.1016/j.engstruct.2010.02.025</pub-id></citation></ref>
<ref id="B38"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pall</surname> <given-names>A. S.</given-names></name> <name><surname>Marsh</surname> <given-names>C.</given-names></name></person-group> (<year>1982</year>). <article-title>Response of friction damped braced frames.</article-title> <source><italic>J. Struct. Div. ASCE</italic></source> <volume>108</volume> <fpage>1313</fpage>&#x2013;<lpage>1323</lpage>.</citation></ref>
<ref id="B39"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shiomi</surname> <given-names>T.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2016</year>). <article-title>Explicit optimal hysteretic damper design in elastic-plastic structure under double impulse as representative of near-fault ground motion.</article-title> <source><italic>Int. J. Earthq. Impact Eng.</italic></source> <volume>1</volume> <fpage>5</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1504/ijeie.2016.10000944</pub-id></citation></ref>
<ref id="B40"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shiomi</surname> <given-names>T.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2018</year>). <article-title>Dual hysteretic damper system effective for broader class of earthquake ground motions.</article-title> <source><italic>Int. J. Earthq. Impact Eng.</italic></source> <volume>2</volume> <fpage>175</fpage>&#x2013;<lpage>202</lpage>. <pub-id pub-id-type="doi">10.1504/ijeie.2018.093391</pub-id></citation></ref>
<ref id="B41"><citation citation-type="journal"><collab>SNAP</collab> (<year>2015</year>). <source><italic>An Elastic-Plastic Analysis Program for Arbitrary-Shape Three-Dimensional Frame Structures, Ver.6.1.</italic></source> <publisher-loc>Tokyo</publisher-loc>: <publisher-name>Kozo System, Inc</publisher-name>.</citation></ref>
<ref id="B42"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Soong</surname> <given-names>T. T.</given-names></name> <name><surname>Dargush</surname> <given-names>G. F.</given-names></name></person-group> (<year>1997</year>). <source><italic>Passive Energy Dissipation Systems in Structural Engineering.</italic></source> <publisher-loc>Chichester</publisher-loc>: <publisher-name>JohnWiley &#x0026; Sons</publisher-name>.</citation></ref>
<ref id="B43"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2009</year>). <source><italic>Building Control with Passive Dampers: Optimal Performance-Based Design for Earthquakes.</italic></source> <publisher-loc>Chichester</publisher-loc>: <publisher-name>John Wiley &#x0026; Sons Ltd</publisher-name>.</citation></ref>
<ref id="B44"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2020</year>). <article-title>New architectural viewpoint for enhancing society&#x2019;s resilience for multiple risks including emerging COVID-19.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>6</volume>:<issue>143</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2020.00143</pub-id></citation></ref>
<ref id="B45"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Takewaki</surname> <given-names>I.</given-names></name> <name><surname>Fujita</surname> <given-names>K.</given-names></name> <name><surname>Yamamoto</surname> <given-names>K.</given-names></name> <name><surname>Takabatake</surname> <given-names>H.</given-names></name></person-group> (<year>2011</year>). <article-title>Smart passive damper control for greater building earthquake resilience in sustainable cities.</article-title> <source><italic>Sustain. Cities Soc.</italic></source> <volume>1</volume> <fpage>3</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1016/j.scs.2010.08.002</pub-id></citation></ref>
<ref id="B46"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tani</surname> <given-names>T.</given-names></name> <name><surname>Maseki</surname> <given-names>R.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2017</year>). <article-title>Innovative seismic response controlled system with shear wall and concentrated dampers in lower stories.</article-title> <source><italic>Front. Built Environ.</italic></source> <volume>3</volume>:<issue>57</issue>. <pub-id pub-id-type="doi">10.3389/fbuil.2017.00057</pub-id></citation></ref>
<ref id="B47"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Uetani</surname> <given-names>K.</given-names></name> <name><surname>Tsuji</surname> <given-names>M.</given-names></name> <name><surname>Takewaki</surname> <given-names>I.</given-names></name></person-group> (<year>2003</year>). <article-title>Application of optimum design method to practical building frames with viscous dampers and hysteretic dampers.</article-title> <source><italic>Eng. Struct</italic></source> <volume>25</volume> <fpage>579</fpage>&#x2013;<lpage>592</lpage>. <pub-id pub-id-type="doi">10.1016/s0141-0296(02)00168-2</pub-id></citation></ref>
<ref id="B48"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xia</surname> <given-names>C.</given-names></name> <name><surname>Hanson</surname> <given-names>R. D.</given-names></name></person-group> (<year>1992</year>). <article-title>Influence of ADAS element parameters on building seismic response.</article-title> <source><italic>J. Struct. Eng. ASCE</italic></source> <volume>118</volume> <fpage>1903</fpage>&#x2013;<lpage>1918</lpage>. <pub-id pub-id-type="doi">10.1061/(asce)0733-9445(1992)118:7(1903)</pub-id></citation></ref>
</ref-list>
</back>
</article>