Abstract
Toxic metal contamination in aquatic environments remains a persistent threat to human health and ecosystems. Yet, the high cost, infrastructure demands, and centralized nature of conventional analytical methods constrain routine monitoring. Ion-imprinted polymers (IIPs), a subclass of molecularly imprinted polymers, have emerged as promising synthetic recognition materials for metal-ion sensing because they generate coordination-defined binding sites with high selectivity, chemical stability, low cost, and reusability. This review summarizes recent advances in Ion-imprinted polymer (IIP)-based sensing technologies for toxic metal-ion detection in water from 2016 to 2026. It examines the fundamental recognition chemistry of IIPs, major synthesis strategies used to generate selective binding cavities, and the principal sensing platforms, including electrochemical, optical/fluorescence, and piezoelectric systems. Attention is given to the role of conductive nanomaterials in enhancing electron transfer. Additional emphasis is placed on multiplex metal-detection strategies and validation in real environmental samples. Across literature, electrochemical platforms dominate the field owing to their sensitivity, portability, and compatibility with miniaturized devices, although analytical performance often depends strongly on interfacial engineering and matrix conditions. Current challenges, including reproducibility, selectivity in complex waters, and field deployment, are discussed together with future directions needed to enable practical water-quality monitoring technologies.
1 Introduction
Ensuring access to safe and clean water is a critical global priority due to its implications for public health, environmental sustainability, and socioeconomic development (; ). Among water contaminants, toxic metal pollution represents a persistent challenge because of its widespread occurrence and long-term environmental stability (; ). Industrial, agricultural, and urban activities introduce metal contaminants into aquatic systems, where they remain environmentally relevant even at trace concentrations (). Effective monitoring strategies are therefore essential to support water safety management and regulatory oversight (; ).
Toxic metal ions are prioritized in water quality monitoring because of the difficulty associated with their detection and quantification. In aquatic environments, metals can distribute among dissolved phases, suspended particles, sediments, and biological systems (; ). At the same time, regulatory limits are extremely low, often approaching the limits of detection (LODs) of conventional analytical techniques (). The chemical complexity of natural waters, including variable pH, ionic strength, dissolved organic matter, and competing ions, further complicates selective metal analysis. This necessitates highly sensitive and selective detection approaches capable of reliable performance in real environmental matrices (; ).
Conventional analytical methods, such as inductively coupled plasma mass spectrometry (ICP-MS), atomic absorption spectroscopy (AAS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), remain the reference techniques for toxic metal determination due to their high sensitivity and multi-element capability (; Yang et al., 2021). ICP-MS offers ultra-low LODs and a wide dynamic range, but requires expensive instrumentation, centralized laboratories, and skilled personnel (; Yang et al., 2021). As a result, their suitability for rapid, on-site, and decentralized monitoring remains limited, especially in remote or resource-limited regions where toxic metal contamination may be most severe (). Compared with conventional laboratory-based techniques, IIP-based sensors offer a different analytical role. ICP-MS and ICP-OES provide excellent sensitivity, accuracy, and multi-element capability, making them essential for confirmatory analysis, whereas AAS is widely used for metal quantification but generally requires laboratory instrumentation and trained operators. In contrast, IIP-based sensors combine selective recognition with portable electrochemical, optical, or piezoelectric readout and are therefore attractive for rapid screening, decentralized monitoring, and potential field deployment. Although their analytical performance depends strongly on polymer design, transducer configuration, and matrix composition, they offer important advantages in terms of low cost, rapid response, simple operation, and portability. Therefore, IIP-based sensors should be considered complementary tools for screening and decentralized monitoring rather than direct replacements for reference laboratory methods (; ; Yang et al., 2021; Zheng et al., 2021).
To address these limitations, sensor-based technologies have emerged as promising tools for environmental monitoring because they enable rapid detection, portability, and potential real-time analysis (). In such systems, the recognition element plays a critical role in determining selectivity toward the target ion. However, maintaining selectivity in complex matrices remains challenging due to cross-reactivity and environmental variability (). Although biological recognition elements have been explored due to their inherent specificity, their practical deployment is often hindered by limited stability, metal-induced denaturation, and poor long-term reproducibility under environmental conditions (; ).
Ion-imprinted polymers (IIPs), a subclass of molecularly imprinted polymers (MIPs), are synthesized by polymerizing functional monomers around metal-ligand complexes, followed by template removal to generate coordination-defined binding cavities. These artificial recognition sites enable selective rebinding of the target analyte while maintaining high chemical and mechanical stability (). In contrast to biological receptors, MIPs exhibit resistance to pH variation, temperature changes, and organic solvents, making them well-suited for environmental sensing applications in complex aqueous matrices (; Zheng et al., 2021). Because these recognition cavities originate from pre-organized metalāligand complexes, the selectivity of IIPs is governed not only by cavity size and shape but also by the coordination geometry, donor-atom identity, ligand denticity, and metal-ion speciation during both imprinting and rebinding.
In IIPs, metal-ligand complexes are used as templates during IIP synthesis, producing coordination-specific cavities that match the size, geometry, and coordination environment of the target ion (; ). This strategy significantly improves selectivity while reducing interference from abundant cations such as Ca2+, Mg2+, and Na+ in natural waters (). Consequently, IIP-based materials have demonstrated strong analytical performance for detecting toxic metals, including Pb2+, Cd2+, Hg2+, and As3+ at trace and ultra-trace concentrations relevant to environmental monitoring (). The integration of IIPs with diverse sensing platforms, including electrochemical, optical, piezoelectric, and nanomaterial-based transducers, has further enhanced detection sensitivity and selectivity (; ; Zarejousheghani et al., 2021). Such systems enable low detection limits, improved performance in complex matrices, and stable operation under environmental conditions, highlighting their potential as cost-effective tools for water quality monitoring (; Zheng et al., 2021). Many reported IIP-based sensors already demonstrate analytical performance compatible with international drinking water standards while functioning in real water samples with minimal sample preparation (). Among these sensing approaches, electrochemical platforms have become particularly prominent due to their high sensitivity, portability, and compatibility with miniaturized devices.
This review critically examines recent advances in IIP sensors for toxic metal-ion detection in water from 2016 to 2026. Emphasis is placed on imprinting strategies, coordination-based recognition mechanisms, and integration with electrochemical, optical, and piezoelectric sensing platforms. The analytical performance of reported systems is compared with respect to sensitivity, selectivity, and applicability in real water matrices. Remaining challenges, including reproducibility, matrix interference, and field deployment, are discussed together with emerging design strategies needed to translate IIP-based sensors into practical water-quality monitoring technologies.
Several recent reviews have examined molecularly imprinted polymer (MIP) and IIP-based sensing from complementary perspectives, including environmental analysis, clean-water monitoring, priority pollutant detection, water and wastewater analysis, trace toxic metal-ion detection, portable electrochemical sensing, and water-quality monitoring (; ; ; ; ; Zarejousheghani et al., 2021; Zheng et al., 2021), Additional reviews have focused on toxic metal-ion sensors in aquatic environments, IIPs for toxic metal-ion detection and wastewater treatment, MIPs as environmental separation tools, nanomaterial-based ion-imprinted electrochemical sensors, microfluidic toxic metal-ion detection, nanomaterial-enhanced trace-metal sensing, and microfluidic micro-mixing strategies for seawater analysis (; ; ; ; ; ; Yu et al., 2022. Despite these contributions, the literature remains distributed across broad MIP sensor reviews, electrochemical platform reviews, wastewater treatment studies, environmental separation studies, microfluidic and FET-based sensing reviews, nanomaterial-enhanced sensor reviews, and toxic metal-ion monitoring reviews. Therefore, the present review is positioned as a focused and up-to-date synthesis of IIP-based sensors for toxic metal-ion detection in water from 2016 to 2026. Unlike previous reviews, it integrates coordination chemistry, imprinting strategy, synthesis method, transduction platform, nanomaterial-assisted signal enhancement, multiplex detection, analytical performance, and real-water validation, providing a practical framework for evaluating IIP sensors for rapid screening, decentralized monitoring, and potential field deployment.
2 Overview of IIP technology
2.1 Principles
MIPs are synthetic polymer networks engineered to selectively recognize target molecules and are often described as artificial analogues of antibody-antigen systems (). Molecular imprinting involves the formation of a pre-polymerization complex between a template species and functional monomers through covalent or, more commonly, noncovalent interactions such as hydrogen bonding, electrostatic forces, and ĻāĻ interactions (). During polymerization, the monomer-template complex becomes fixed within a highly cross-linked three-dimensional (3D) matrix, typically stabilized by multifunctional crosslinkers (). Subsequent removal of the template generates recognition cavities complementary in size, shape, and chemical functionality, enabling selective rebinding from complex matrices (; Ye and Mosbach, 2008). A schematic representation of the imprinting process is shown in Figure 1.
FIGURE 1
The analytical performance of MIPs is commonly evaluated through parameters such as imprinting factor, binding capacity, and response time, which compare the behavior of imprinted and non-imprinted polymers. A key advantage of MIPs is their chemical, thermal, and mechanical robustness, allowing operation under environmental conditions unsuitable for biological receptors (). As a result, MIPs have been widely explored as recognition elements in sensing, separation, and environmental analytical technologies (L. Ye and Mosbach, 2008).
IIPs differ from organic-molecule imprinting because recognition is governed primarily by metal-ligand coordination chemistry. In IIP synthesis, the template ion forms a coordination complex with functional monomers before polymerization. The polymerization mixture typically contains functional monomers, crosslinkers, initiators, and a porogenic solvent that generates accessible porosity. Polymerization fixes the spatial arrangement of coordinating groups around the metal center, and template removal subsequently produces cavities that retain the preferred coordination geometry and donor-atom environment of the template ion ().
In toxic metal-ion sensing applications, imprinting performance strongly depends on matching the coordination chemistry of the target ion. Soft metal ions such as Hg2+ and Pb2+ preferentially bind soft donor atoms (e.g., sulfur or nitrogen), whereas harder metal ions favor oxygen donors. Proper ligand selection, therefore, enhances binding affinity and discrimination against competing ions. Selectivity is further influenced by solution chemistry, particularly pH, which affects both proton competition for ligand sites and metal hydrolysis equilibria (). Careful control of these parameters can significantly improve recognition performance in complex aqueous matrices.
Early studies demonstrated that polymer networks could be chemically āprogrammedā to selectively rebind template ions following removal, establishing the feasibility of ionic imprinting strategies (). Subsequent work extended these concepts to environmentally relevant metals such as Hg2+, enabling selective preconcentration and detection under realistic analytical conditions (). These studies laid the foundation for the development of IIP-based materials as selective sorbents and recognition elements for environmental sensing systems.
2.1.1 Coordination chemistry and metalāligand complex formation in IIPs
Ion-imprinted polymer formation is fundamentally governed by coordination chemistry because the template metal ion first forms a pre-polymerization complex with functional monomers containing suitable donor atoms. In this process, the metal ion acts as a Lewis acid, while the functional monomer behaves as a Lewis base by donating electron density through donor atoms such as oxygen, nitrogen, sulfur, or phosphorus. The resulting metalāligand complex defines the spatial arrangement of the coordinating groups around the template ion before polymerization. During polymerization, this arrangement is fixed within the cross-linked polymer network. Subsequent removal of the template ion leaves behind binding cavities that retain memory of the original metal-ion size, charge distribution, preferred coordination geometry, and donor-atom environment. As a result, the imprinted polymer can selectively rebind the target ion from aqueous samples through coordination interactions that partially reproduce the original pre-polymerization complex ().
The mechanism of complex formation generally involves coordination between vacant orbitals of the metal ion and lone-pair electrons from donor atoms in the functional monomers. Monomers bearing carboxyl, hydroxyl, carbonyl, amine, pyridyl, thioether, or Schiff-base groups are commonly used because these functional groups can coordinate metal ions through O-, N-, or S-donor atoms. The stability of the pre-polymerization complex depends on several factors, including the charge and ionic radius of the metal ion, ligand denticity, donor-atom type, coordination number, geometry, pH, solvent composition, and competition from other ions. Multidentate ligands can provide stronger and more selective binding than monodentate ligands because several donor atoms interact simultaneously with the same metal ion, improving complex stability and helping preserve cavity fidelity after ().
The selectivity of IIPs is strongly influenced by the compatibility between the target metal ion and the donor atoms used in the imprinting process. According to hard and soft acidābase principles, harder metal ions generally favor harder donor atoms such as oxygen. In contrast, softer and more polarized metal ions preferentially interact with softer donor atoms such as sulfur or nitrogen. Therefore, ligand selection should be matched to the coordination preference of the target ion. For example, Hg2+ and Pb2+ often show strong affinity toward sulfur- and nitrogen-containing ligands, while ions such as Cd2+, Cu2+, Ni2+, and Cr3+ may interact effectively with nitrogen- or oxygen-containing functional groups depending on their coordination environment and solution chemistry. This matching between metal-ion characteristics and ligand donor atoms is essential for producing selective binding sites and reducing cross-reactivity with competing ions in natural water matrices ().
The significance of these coordination interactions extends beyond selective recognition. The strength and reversibility of metalāligand binding determine template removal efficiency, rebinding kinetics, sensor regeneration, and long-term stability. If the metalāligand complex is too weak, the imprinted cavity may have poor fidelity and low selectivity. Conversely, if the complex is too strong, template removal may be incomplete, or rebinding may become slow and difficult to reverse. Therefore, effective IIP design requires a balance between complex stability during polymerization and reversible rebinding during sensing. In aqueous samples, pH and metal speciation are especially important because protonation of ligand sites, hydrolysis of metal ions, and complexation with dissolved organic matter can reduce the concentration of free metal ions available for rebinding. Thus, coordination chemistry directly controls both the formation of selective recognition cavities and the analytical performance of IIP-based sensors in real water matrices ().
2.2 Synthesis methods
Multiple synthetic approaches have been developed to produce IIPs with tailored morphology, binding accessibility, and analytical performance. The polymerization strategy strongly influences site accessibility, particle morphology, and mass-transfer kinetics, all of which affect sensor performance. Thus, different preparation methods are often selected depending on whether the application involves adsorption, separation, or sensing.
2.2.1 Bulk free-radical polymerization
Bulk free-radical polymerization remains one of the most widely used methods for producing IIPs due to its simplicity. In this approach, a metal-ligand complex is copolymerized with crosslinkers in the presence of a radical initiator to form a highly cross-linked polymer network. The resulting monolithic polymer is then crushed, ground, and sieved to generate particles, followed by template removal using acidic or chelating solutions (). Although bulk polymerization provides high mechanical stability, grinding may damage recognition sites and generate particles with broad size distributions. In addition, many binding sites remain buried within the polymer matrix, limiting diffusion and slowing binding kinetics ; ). These limitations have motivated alternative polymerization strategies that improve site accessibility.
2.2.2 Precipitation polymerization
Precipitation polymerization addresses some limitations of bulk synthesis by generating particles directly without grinding. Polymerization begins in a homogeneous solution containing the template complex, monomers, crosslinkers, and initiator dissolved in a large volume of porogenic solvent. As polymer chains grow, they become insoluble and precipitate to form uniform micro- or nanoscale particles [40]. This method often produces materials with higher surface area and improved reproducibility compared with bulk polymers, although particle morphology remains sensitive to solvent composition and crosslinking conditions (; ).
2.2.3 Suspension polymerization
Suspension polymerization forms spherical polymer beads by dispersing the monomer phase containing the template complex into an aqueous phase stabilized by surfactants. Each droplet acts as an independent micro-reactor in which polymerization occurs, producing mechanically stable beads suitable for packed-bed applications (). However, controlling droplet stability and preventing template partitioning into the continuous phase can be challenging, and particle size distributions may vary depending on agitation and stabilizer concentration.
2.2.4 Emulsion and inverse-emulsion polymerization
Emulsion-based polymerization generates polymer particles within surfactant-stabilized droplets, often producing smaller particle sizes and larger interfacial areas compared with suspension systems. In inverse emulsions, polymerization occurs within water droplets dispersed in an oil phase. These approaches reduce diffusion distances and enable rapid adsorption kinetics (). However, surfactant removal can complicate purification, and particle morphology strongly depends on droplet stability during polymerization (; ).
2.2.5 Surface imprinting (coreāshell architectures)
Surface imprinting strategies were developed to overcome mass-transfer limitations associated with bulk imprinting. In these systems, a thin imprinted polymer layer is formed on a supporting material to create a core-shell architecture in which recognition sites are located primarily near the surface. This configuration enhances template accessibility, rebinding kinetics, and template removal efficiency (). Surface-imprinted materials are particularly attractive for sensing applications because recognition sites are directly exposed to the analyte solution. However, synthesis typically requires additional support preparation and careful control of film thickness to avoid diffusion limitations (; ).
2.2.6 Electropolymerization (electro-synthesized IIP films)
Electropolymerization provides a powerful route for generating thin imprinted films directly on electrode surfaces. Polymerization is initiated electrochemically in a solution containing electropolymerizable monomers and the template ion, allowing precise control of film thickness through applied potential or deposition time (). Because the resulting films are thin and integrated with the sensing interface, electropolymerized IIPs often exhibit rapid mass transport and high analytical sensitivity. However, this approach is limited to monomers capable of electrochemical polymerization, and film stability may depend strongly on deposition conditions (; ).
Overall, IIP synthesis strategies involve trade-offs between synthetic simplicity, particle uniformity, and binding-site accessibility. Bulk and suspension polymerization remain attractive for large-scale sorbent production, whereas precipitation polymerization, surface imprinting, and electropolymerization are increasingly favored for sensing applications because they generate surface-accessible recognition sites and improved mass-transfer kinetics. Table 1 summarizes the principal advantages and limitations of common IIP preparation approaches.
TABLE 1
| Method | Key advantages | Key limitations | Ref. |
|---|---|---|---|
| Bulk free-radical polymerization | Simple synthesis; high crosslinking and stability; flexible monomer design | Grinding required; broad particle size; many buried sites ā slower kinetics | |
| Precipitation polymerization | No grinding; relatively uniform particles; higher surface area | Large solvent volume required; particle morphology sensitive to solvent conditions | Zhang et al. (2022) |
| Suspension polymerization | Direct bead formation; tunable bead size; mechanically robust particles | Requires stable droplet dispersion; possible template partitioning; broader size distribution | |
| Emulsion/inverse-emulsion polymerization | Small particles; high interfacial area; rapid adsorption/desorption kinetics | Surfactant removal required; synthesis conditions strongly affect reproducibility | |
| Surface imprinting (coreāshell; magnetic supports) | Surface-accessible sites; rapid binding and elution; effective for sensors and solid-phase extraction | Multi-step synthesis; film thickness must be controlled; support materials increase complexity | |
| Electropolymerization (thin IIP films) | Direct electrode integration; controlled film thickness; fast response; suitable for miniaturized sensors | Limited monomer selection; possible film fouling/delamination; small sorbent capacity |
Common IIP synthesis strategies used in toxic metal-ion sensing and separation.
From a sensing perspective, the choice of synthesis method strongly determines binding-site accessibility, response time, and reproducibility. Bulk polymerization provides mechanically stable materials and simple preparation, but many recognition sites remain buried inside the polymer network, leading to slower mass transfer and reduced accessibility of hydrated metal ions. Precipitation and emulsion polymerization generate smaller particles with higher surface area, which can improve rebinding kinetics; however, their morphology and reproducibility depend strongly on solvent composition, surfactant use, and polymerization conditions. Surface imprinting and electropolymerization are generally more suitable for sensor fabrication because they localize recognition sites near the transducer surface, reduce diffusion barriers, and improve signal coupling. Nevertheless, these methods require careful control of film thickness because overly thick films can block ion transport and increase resistance, whereas very thin films may reduce binding capacity. Therefore, IIP synthesis should be selected according to the intended sensing format, balancing synthetic simplicity, binding-site accessibility, mechanical stability, and compatibility with the transducer interface (; ; ).
3 Sensor platforms, configurations, and transduction strategies
() IIPs have been integrated with diverse sensing platforms for selective detection of toxic metal ions in aqueous systems. In these sensors, analytical performance depends not only on imprinting chemistry but also on how the recognition layer interfaces with the transducer and how binding events are converted into measurable signals. Consequently, sensor architecture, including polymer configuration, interfacial design, and transduction strategy, strongly influences sensitivity, selectivity, and response kinetics. Among reported configurations, electrochemical sensors dominate the field because of their compatibility with aqueous media, high sensitivity, and straightforward miniaturization. Optical and fluorescence approaches provide alternative signal generation based on light-matter interactions, while piezoelectric devices depend on mass-sensitive transduction. Each architecture represents a different strategy for translating coordination-driven recognition within IIP cavities into measurable analytical responses.
The sensing mechanism in IIP-based platforms depends on the coupling between selective ion rebinding and the transduction process. In electrochemical sensors, rebinding of the target ion within imprinted cavities changes interfacial charge transfer, redox current, impedance, or stripping response. In optical and fluorescence sensors, ion rebinding modifies absorbance, fluorescence intensity, refractive index, or plasmonic response. In piezoelectric sensors, selective binding increases the mass of the sensing layer and produces a measurable frequency shift. Therefore, analytical performance is not controlled only by the selectivity of the imprinted cavities, but also by how efficiently the transducer converts ion-recognition events into measurable signals. This explains why sensors with similar imprinting chemistry may show different sensitivities, response times, and limits of detection depending on the selected transduction strategy (; ; ; ).
3.1 Electrochemical sensors
Electrochemical platforms represent the most mature class of IIP-based toxic metal-ion sensors because they enable sensitive detection in aqueous media while allowing direct integration with miniaturized electrodes (). In these systems, the IIP layer acts as a selective coordination interface that modulates electron transfer or mass transport at the electrode surface. A common implementation involves coating a glassy carbon electrode with an IIP film immobilized using a polymeric binder (). Metal ions selectively rebind within the polymer matrix, altering the interfacial electrochemical response typically measured by voltammetry. Although this architecture offers simple fabrication, diffusion limitations within the polymer film and increased electrical resistance from binders can reduce sensitivity.
Multilayer designs incorporating conductive intermediate layers have therefore been developed. For example, Velempini et al. electropolymerized a polypyrrole layer on a glassy carbon electrode before depositing sulfur-containing IIP particles for Hg2+ detection (). The conducting polymer improves adhesion and electron transport, whereas the imprinted particles provide selective binding sites. Since multilayer interfaces may increase charge-transfer resistance and hinder analyte diffusion, a more integrated design using a screen-printed carbon electrode (SPCE) with electropolymerized IIP films (Figure 2) has been developed (). In this approach, the polymer layer is grown directly on the electrode surface from a monomer-template solution. Template removal produces surface-accessible coordination cavities that are electrically coupled to the electrode, eliminating binders and improving sensitivity.
FIGURE 2
Oseyemi and Rezai demonstrated an advanced configurations integrating IIPs into microfluidic electrochemical systems as illustrated in Figure 2 (). In these devices, the imprinted polymer is implemented as a membrane within a flow-through chamber positioned between planar electrodes. Controlled fluid flow enhances mass transport and reduces sample volume requirements. However, microfluidic architectures introduce additional engineering complexity and may be susceptible to fouling in environmental samples. Overall, electrochemical IIP sensors provide strong analytical performance through direct coupling of coordination-based recognition with sensitive electrochemical readout mechanisms. Achieving optimal performance requires balancing film thickness, binding-site accessibility, and interfacial conductivity.
3.2 Optical and fluorescence sensors
Optical sensors represent another important class of IIP-based detection platforms because they enable non-electrical signal transduction and often allow simple visual or spectroscopic readout (). In these systems, analyte binding within the imprinted polymer alters optical properties such as absorbance, reflection, or refractive index. One common configuration involves optical fiber sensors, where a surface-imprinted polymer layer is formed on a quartz or glass fiber (). The binding of the target ion modifies the refractive index or optical absorption at the sensing interface, enabling remote detection through transmitted or reflected light. Although these sensors are compact and suitable for in-situ monitoring, surface fouling and polymer degradation can limit long-term stability.
Simpler formats use planar or particulate IIP coatings on transparent substrates, in which metal-ion binding induces a visible color change or a spectroscopic absorbance change (). These systems emphasize low-cost fabrication and straightforward readout but are often limited by diffusion-controlled transport within the polymer layer. As shown in Figure 3, paper-based optical sensors provide an alternative low-cost strategy (). In these devices, IIPs are formed on cellulose fibers, where the paper acts as both structural support and fluid-transport medium. Capillary flow enables passive sample transport while colorimetric changes within the imprinted layer generate the analytical signal. Although attractive for portable monitoring, these devices may suffer from mechanical fragility and dimensional instability during prolonged exposure to aqueous samples.
FIGURE 3
Fluorescence-based IIP sensors provide higher analytical sensitivity by coupling imprint-based recognition with fluorescence modulation (; ). Particle-based fluorescent IIPs prepared by precipitation polymerization incorporate fluorophores within the polymer matrix, and metal-ion binding alters emission intensity. While these systems offer rapid response due to surface-accessible binding sites, stable optical measurements in turbid environmental samples remain challenging. More complex architectures, combine polydopamine-coated substrates with aptamer-assisted imprinting (Ye et al., 2025). In these sensors, a thin polydopamine film forms surface-accessible recognition cavities while fluorescence signals are generated at the solid-liquid interface. Although these designs provide high sensitivity, their reliance on noble-metal substrates and complex fabrication can limit scalability.
3.3 Piezoelectric sensors
Piezoelectric transducers, particularly quartz crystal microbalance (QCM) devices, represent another platform for IIP-based metal detection (). In QCM sensors, analyte binding shifts the resonance frequency of a vibrating quartz crystal due to mass accumulation on the sensing surface. Typically, a thin IIP film is immobilized on the gold-coated surface of the quartz crystal [66]. Metal-ion rebinding increases the mass of the sensing layer, producing a frequency shift proportional to analyte concentration. Because the signal arises from mass changes rather than optical or electrochemical processes, QCM sensors enable label-free detection and can operate effectively in aqueous environments. However, analytical performance depends strongly on the mechanical stability and adhesion of the imprinted polymer film, which must withstand repeated swelling and deswelling during operation. In addition, QCM systems require controlled flow conditions and vibration isolation, which can complicate miniaturization for field deployment.
Overall, electrochemical IIP sensors currently offer the most favorable balance between sensitivity, portability, and compatibility with aqueous samples, especially when stripping voltammetry or differential pulse techniques are used. Their high sensitivity arises from the combination of selective preconcentration within imprinted cavities and efficient electrochemical signal amplification at the electrode surface. Optical and fluorescence sensors provide simpler or non-electrical readout and are attractive for disposable, visual, or remote sensing formats, but their performance can be affected by turbidity, background color, fluorescence quenching, and optical scattering in real waters. Piezoelectric sensors enable label-free detection based on mass changes, but they require mechanically stable films, controlled flow conditions, and reduced environmental vibration. Thus, platform selection should be guided by the intended application: electrochemical sensors are best suited for trace quantification, optical systems for rapid field screening, and piezoelectric devices for label-free monitoring under controlled (; ; ).
4 Types of toxic metal ions detected using IIP-Based sensors
IIP sensors have been widely applied for selective detection of toxic metal ions in water, with imprinting strategies tailored to the coordination chemistry and speciation behavior of individual metals. In these systems, the analytical response arises from rebinding of the target ion within cavities whose geometry and performance depend strongly on the compatibility between the imprinted coordination environment and the target ionās coordination preferences. IIP sensors have been reported for both single-metal detection and simultaneous multi-metal monitoring (; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; Zhiani et al., 2016; Zhou et al., 2020). The following sections summarize representative systems for key environmentally relevant metals, with attention to analytical performance, preferred coordination environments, donor-atom interactions, and matrix-dependent speciation behavior.
4.1 Cadmium (Cd2+)
Cadmium is a priority environmental contaminant due to its high toxicity, potential for bioaccumulation, and long biological half-life (Wang et al., 2021). Cd2+ typically forms stable complexes with nitrogen- and sulfur-donor ligands, making these functional groups suitable for imprinting strategies. Hu et al. reported an electrochemical sensor based on a polypyrrole/reduced graphene oxide composite IIP in which Cd2+ was coordinated with nitrogen-containing functional groups during polymerization (). After template removal (Figure 4), selective Cd-N rebinding enabled detection using square-wave anodic stripping voltammetry (SWASV) with a detection limit of 0.26 μgĀ L-1 and a linear range of 1ā100 μgĀ L-1. Minimal interference from Mg2+, Zn2+, Mn2+, and Cr species demonstrated effective coordination matching.
FIGURE 4
From a coordination perspective, Cd2+ is a borderline-soft divalent ion that can interact with N-, S-, and O-donor ligands; therefore, monomers containing amine, pyridyl, thiol, or carboxyl groups are often selected to create Cd2+-compatible binding sites.
An impedance-based electrochemical sensor developed by Sadiq et al. used oxygen-donor ligands within the polymer matrix to generate Cd2+-specific cavities (). Although the system showed good selectivity against Zn2+, Cu2+, Pb2+, and Hg2+, its detection limit (ā¼0.10Ā mgĀ L-1) was significantly higher than that of voltammetric systems, highlighting the influence of transduction strategy on sensitivity. More recently, Fafa and Zazoua reported an electropolymerized PEDOT-based IIP film on a screen-printed electrode incorporating sulfur- and oxygen-donor ligands (). The resulting sensor achieved a detection limit of 0.07 μgĀ L-1 over a range of 0.5ā75 μgĀ L-1, reflecting improved ligand coordination and direct electrode integration. However, Cd2+ detection remains sensitive to solution chemistry, particularly hydrolysis and complexation equilibria.
4.2 Lead (Pb2+)
Lead is one of the most widely studied targets in IIP sensing because of its severe neurotoxicity and extremely low regulatory limits in drinking water (). Pb2+ exhibits flexible coordination geometries and strong affinity for nitrogen- and oxygen-donor ligands. Shamsipur et al. developed a Pb2+-imprinted nanoparticle incorporating terpyridine ligands that form strong PbāN complexes (). Coupled with differential pulse anodic stripping voltammetry (DPASV), the sensor achieved a detection limit of approximately 0.1Ā nM with strong selectivity against Cd2+, Cu2+, Zn2+, and Ni2+.
Optical sensing strategies have also been explored. Meza López et al. reported an optical fiber IIP sensor based on Pb-O coordination interactions (Figure 4), enabling reflectance-based detection with a limit of detection (LOD) of 85 ng L-1 (). Although optical systems offer simpler instrumentation, their sensitivity is generally lower than that of electrochemical stripping techniques. Additional electrochemical sensors employing carboxylate and amine functional groups have achieved sub-ppb sensitivity with minimal interference from Cu2+ and Fe3+ (). Microfluidic integration has also been demonstrated using Pb2+-imprinted membranes incorporated into flow-based electrochemical devices (). However, Pb2+ speciation and complexation with dissolved organic matter remain key factors influencing sensor performance in natural waters.
The relatively flexible coordination sphere of Pb2+ allows interaction with multiple donor atoms, but stronger and more selective recognition is generally achieved when the imprinted cavity preserves both the appropriate donor-atom arrangement and the steric environment around the Pb2+ template.
4.3 Chromium and mercury
Chromium presents a unique sensing challenge because it exists primarily as Cr3+ and Cr6+, which exhibit distinct chemical behaviors and toxicological profiles (). For Cr3+ detection, Aravind and Mathew developed an IIP sensor utilizing carboxylate-based coordination with trivalent chromium (). The system enabled differential pulse voltammetric (DPV) detection with a limit of approximately 0.05 µM, although performance was affected by chromium hydrolysis near neutral pH. For Cr6+ detection, Wu et al. reported an electrodeposited chitosan-graphene IIP sensor (Figure 5), achieving an ultra-low detection limit of 6.4 Ć 10ā10Ā M using DPV (). Improved sensitivity partly reflects the higher solubility and mobility of hexavalent chromium species.
FIGURE 5
For chromium species, coordination chemistry is complicated by oxidation state and aqueous speciation because Cr3+ behaves as a cationic species capable of coordinating with oxygen- or nitrogen-donor ligands, whereas Cr6+ is commonly present as oxyanion forms under many aqueous conditions.
Mercury is another critical contaminant due to its extreme toxicity and bioaccumulation potential (). Hg2+ behaves as a soft Lewis acid with strong affinity for sulfur- and nitrogen-donor ligands. Rebolledo-Perales et al. reported a pyrrole-based IIP sensor in which Hg2+ recognition occurred through nitrogen coordination interactions (Figure 5) (). Using anodic stripping voltammetry (ASV), the sensor achieved a detection limit of 0.02Ā mgĀ L-1 with high selectivity against Cd2+, Pb2+, and Cu2+. A related system using sulfur-containing ligands strengthened Hg2+ binding within imprinted cavities (Figure 5) and achieved a detection limit near 70Ā nM (). Nevertheless, Hg2+ detection remains sensitive to pH-dependent hydrolysis and complexation with natural ligands in environmental waters.
Consequently, sulfur-containing ligands can improve Hg2+ recognition because soft donor atoms form stronger interactions with soft, polarizable metal centers, increasing cavity selectivity toward mercury over harder competing ions.
4.4 Other toxic metal ions
IIP sensors have also been developed for metals such as Cu2+, Ni2+, Ag+, and As3+. These systems illustrate the adaptability of imprinting chemistry to different coordination preferences and environmental monitoring needs (). Di Masi et al. reported a Cu2+-imprinted electrochemical sensor based on amine coordination with a detection limit of 2.7Ā nM (). Although the sensor maintains selectivity against competing ions, Cu2+ speciation and complexation in natural waters may influence analytical accuracy ().
Nickel detection has been demonstrated using Ni2+-imprinted chitosan materials integrated with optical fiber sensors, achieving LOD near 1Ā nM (). However, signal attenuation in natural waters was observed due to matrix effects such as dissolved organic matter and ionic strength. In addition, silver detection has been achieved using Ag+-imprinted polymers containing sulfur- and nitrogen-donor ligands, enabling nanomolar detection using differential pulse stripping voltammetry (DPSV) (; Zhiani et al., 2016). Similarly, arsenic detection has been reported using As3+-imprinted polymers integrated with nanoporous gold electrodes, achieving LOD near 7 Ć 10ā12Ā M (). In both cases, the analytical response depends strongly on metal speciation and solution chemistry ().
These examples further demonstrate that IIP design should be metal-specific: Cu2+ and Ni2+ commonly benefit from N- and O-donor coordination environments, Ag+ shows strong affinity for softer sulfur- or nitrogen-containing ligands, and As3+ detection requires careful consideration of hydrolysis and aqueous speciation.
4.5 Simultaneous detection of multiple toxic metal ions
Although most IIP sensors target individual metals, recent studies have explored multi-metal sensing systems to address the complexity of environmental contamination. Zhou et al. reported a dual-metal fluorescent sensor based on ZnSe quantum dots (Figure 5) that enabled simultaneous detection of Cd2+ and Pb2+ with LODs of 0.245 μgĀ L-1 and 0.335 μgĀ L-1, respectively (Zhou et al., 2020). However, differences in coordination strength can influence binding equilibria under varying pH conditions. More complex systems capable of detecting Cu2+, Cd2+, Pb2+, and Hg2+ simultaneously have also been reported, with fluorescence-based LODs as low as 0.007ā0.015 μgĀ L-1 (). Similarly, Hu et al. developed a dual-ion imprinted microfiber sensor array for simultaneous Cr3+ and Ni2+ detection using optical wavelength-shift measurements (). Although sub-nanomolar sensitivity was achieved, slower binding kinetics for Cr3+ were observed due to strong hydration effects.
According to reported studies, Pb2+ and Cd2+ sensors typically achieve the lowest LODs due to favorable coordination kinetics and strong electrochemical stripping responses. In contrast, sensing of metals such as Cr3+ and Hg2+ is more strongly influenced by hydrolysis, hydration effects, and complexation equilibria, which can reduce the concentration of free ions available for rebinding. Collectively, these studies demonstrate that IIP sensors provide a versatile platform for toxic metal-ion detection. However, analytical performance remains strongly influenced by metal coordination chemistry, aqueous speciation, and matrix effects, which remain critical considerations for environmental monitoring applications.
5 Role of nanomaterials in IIP-Based toxic metal-ion sensors
Integration of nanomaterials into IIP sensors has become a key strategy for overcoming intrinsic limitations of polymeric recognition layers, particularly low electrical conductivity, restricted mass transport, and diffusion-limited binding kinetics in aqueous media. In most architectures, nanomaterials do not provide chemical selectivity; instead, they function as interfacial transduction platforms that amplify optical or electrochemical signals generated by metal-ion rebinding within imprinted cavities. Thus, the analytical performance of hybrid IIP sensors depends strongly on the physicochemical compatibility between the nanomaterial scaffold and the imprinted polymer matrix.
Therefore, the coordination-defined IIP cavity remains the primary source of molecular selectivity, whereas nanomaterials mainly improve signal transduction, electron transfer, mass transport, and accessibility of the recognition sites.
Nanomaterials enhance sensor performance through several complementary mechanisms. Conductive nanostructures such as graphene derivatives and carbon nanotubes establish efficient electron-transfer pathways that compensate for the insulating character of polymer films. Semiconductor nanomaterials, including quantum dots, support fluorescence or photoelectrochemical transduction, and nanostructured supports increase the fraction of imprinted sites accessible to hydrated metal ions, thereby improving binding kinetics and sensitivity (). Structurally, nanomaterials are typically integrated as conductive underlayers, dispersed composite fillers, or nanostructured carriers on which imprinting occurs directly. Each configuration affects cavity accessibility, interfacial charge transport, and long-term stability in aqueous systems.
5.1 Graphene family
Graphene and its derivatives are among the most extensively studied nanomaterials in IIP-based toxic metal-ion sensors because their two-dimensional sp2-carbon structure combines high carrier mobility, large surface area, and good compatibility with polymer matrices. Graphene oxide (GO), rGO, electrochemically reduced graphene oxide (ERGO), and 3D porous graphene frameworks are the most common forms used in these systems. GO is often preferred in aqueous IIP sensors because oxygen-containing functional groups improve dispersibility and compatibility with hydrophilic polymers (). For example, a chitosan/GO Cu2+āimprinted sensor used GO to increase the effective surface area and maintain accessibility of imprinted cavities under hydrated conditions (). However, excessive GO loading may compromise electrical communication with the electrode.
By contrast, rGO restores much of grapheneās conductivity while retaining enough surface functionality for polymer anchoring (). In a chemiresistive Cd2+ sensor based on rGO functionalized with an IIP (Figure 6), selective Cd2+ rebinding induced changes in channel conductivity, enabling sensitive detection in water (). In this configuration, the imprinted polymer provides molecular selectivity, whereas rGO converts interfacial charge perturbations into an electrical signal. However, nonspecific adsorption and ionic screening at the graphene-solution interface can attenuate output.
FIGURE 6
ERGO is frequently generated directly on electrode surfaces, producing highly conductive films with strong electrical contact (). This strategy has been used in Cd2+ sensors based on ERGO-supported poly (o-phenylenediamine) imprinted layers, where the graphene substrate improved signal transfer during rebinding (). Nonetheless, graphene restacking and polymer overgrowth may reduce electroactive areas during repeated sensing cycles. Similarly, 3D porous graphene architectures further enhance electrolyte penetration and mass transport (). A Cd2+ sensor employing a 3D porous rGO scaffold showed how interconnected conductive frameworks can improve accessibility of imprinted sites and accelerate ion diffusion through the network (). However, pore blockage and fouling remain important concerns in complex environmental waters.
5.2 Gold nanoparticles
AuNPs are widely used in IIP-based sensors because they combine electrical conductivity, chemical stability, and surface plasmon resonance (SPR) properties. In electrochemical systems, AuNPs act as nanoscale electron-transfer mediators that mitigate the insulating character of imprinted polymer films, whereas in optical systems, they enhance signal output through plasmonic amplification (). In one example, a surface ion-imprinted Cu2+ sensor employed AuNPs as conductive nanocarriers that confined imprinting to an ultrathin interfacial region while enabling efficient electron exchange during target binding (). AuNPs have also been incorporated into SPR-based Cd2+ sensors (Figure 7), where nanoparticles embedded within the imprinted layer enhanced plasmonic coupling between the polymer and gold substrate, amplifying refractive-index changes associated with metal-ion rebinding (). This approach improved sensitivity while maintaining imprint-derived selectivity in wastewater samples.
FIGURE 7
Morphology-engineered AuNPs can further enhance performance. For example, flower-like AuNPs provided increased electroactive area and electrolyte accessibility for improved As3+ detection (Yang et al., 2023). However, nanoparticle aggregation and interfacial degradation remain important limitations during long-term operation in natural waters.
5.3 Carbon nanotubes and quantum dots
Carbon nanotubes (CNTs), particularly multi-walled carbon nanotubes (MWCNTs), provide one-dimensional conductive pathways that efficiently couple polymer recognition events to electrochemical readout. Their high aspect ratio and large accessible surface area make them effective conductive scaffolds for IIP films (). In Pb2+ sensors, MWCNTs frameworks serve as percolated conductive backbones that accelerate electron exchange between imprinted binding sites and the electrode, improving voltammetric sensitivity in aqueous media (). Similar effects have been reported in Hg2+ detection systems combining MWCNTs with Hg2+-imprinted polymer nanoparticles (). Here, CNTs compensate for the insulating nature of polymer particles and improve their dispersion, shortening diffusion paths and enhancing uptake kinetics. Functionalized CNTs have also been applied to Ni2+ sensing, where improved hydrophilicity and dispersion stability increased accessibility of recognition sites (). Despite these advantages, CNT-based composites may degrade through nanotube bundling, surface fouling, or gradual loss of polymer-CNT adhesion during prolonged exposure to water ().
On the other hand, quantum dots (QDs) provide a different function by introducing size-dependent optical properties and efficient photoinduced charge-transfer mechanisms (). In fluorescence-based IIP sensors, QDs often serve as the main signal transducers, while the imprinted polymer supplies selectivity. For example, Mn-doped ZnS quantum dots were integrated into a Cr6+-imprinted system where target binding produced fluorescence quenching through electron transfer between the analyte and the QD surface (Zhang et al., 2019). Encapsulation of the QDs within a thin imprinted shell preserved access to binding sites while maintaining strong optical output. Similarly, graphene quantum dots (GQDs) have also been incorporated into electrochemical IIP sensors for Hg2+ detection, where they act as conductive nanofillers that improve electron transfer and cavity accessibility (Zhang et al., 2019). However, QD-based systems remain limited by photostability, aggregation, and the challenge of maintaining uniform dispersion within polymer matrices.
5.4 Other nanomaterials
Beyond nanocarbons and noble metals, several additional nanomaterials have been explored to address specific limitations of polymer-based IIP sensors. Magnetic core-shell nanoparticles such as Fe3O4@SiO2 provide robust supports for imprinting while enabling magnetic manipulation of the sensing material (). In Cd2+ sensing systems, these particles improved the exposure of imprinted cavities and facilitated integration into fiber-optic platforms ().
For example, graphitic carbon nitride (g-C3N4) nanosheets offer a nitrogen-rich layered structure that promotes charge transfer and enhances interactions with hydrated metal ions (). When incorporated into Hg2+-imprinted polymers, g-C3N4 improved electrochemical response through conductive domain formation within the composite matrix (). Zinc oxide (ZnO) nanorods provide vertically aligned semiconducting architectures that support rapid ionic transport toward imprinted binding sites (), although their chemical stability under acidic conditions remains a concern (). Whereas nanoporous gold structures provide bicontinuous metallic networks with large electroactive areas that facilitate charge transfer beneath imprinted layers, but structural coarsening during long-term use may reduce effective surface area (; ).
5.5 Multi-nanomaterial architectures
Recent studies increasingly combine multiple nanomaterials within a single sensing architecture to exploit complementary functions such as conductivity enhancement, surface-area expansion, and catalytic amplification (; Wu et al., 2020a; Wu et al., 2020b; Zhang et al., 2026). A graphite oxide/MWCNTs composite integrated with an IIP has been used for potentiometric Cu2+ detection, where graphite oxide improved hydrophilicity while MWCNTs provided conductive pathways for signal transduction (). Similarly, chitosan-based IIP sensors incorporating graphene sheets and AuNPs demonstrated how carbon nanostructures and metallic nanoparticles can jointly enhance electron transfer and electroactive area (Wu et al., 2020a).
More complex systems combine MWCNTs, graphene, and AuNPs within a single composite matrix for Pb2+ detection, where carbon nanomaterials form a conductive network and AuNPs act as electron-transfer bridges (Wu et al., 2020b). Emerging hybrid designs also integrate metal-organic frameworks (MOFs) with conductive nanoparticles, such as Ag@MOF nanohybrids (Figure 8, to create porous interfaces that concentrate analytes near imprinted cavities while facilitating electron transfer (). Another example is the incorporation of MoS2@Fe3O4 nanocomposites into IIP layers for Cd2+ sensing, where MoS2 provides large surface area and Fe3O4 enhances charge transport (Zhang et al., 2026). While these multi-nanomaterial systems often improve sensitivity and response kinetics, their performance depends on stable dispersion, robust interfacial bonding, and resistance to degradation during long-term operation in aqueous environments.
FIGURE 8
The contribution of nanomaterials to IIP sensor performance is mainly related to signal amplification, improved mass transport, and enhanced interfacial conductivity rather than direct chemical selectivity. The selectivity is primarily provided by the imprinted cavities, while nanomaterials improve how efficiently the binding event is translated into an analytical signal. Carbon-based nanomaterials such as graphene, rGO, and MWCNTs facilitate electron transfer and reduce the resistance of polymer films, which is particularly important because many IIP layers are intrinsically insulating. Metallic nanostructures such as AuNPs increase electroactive surface area and can provide electrocatalytic or plasmonic amplification. Semiconductor nanomaterials and quantum dots introduce optical or fluorescence transduction pathways, while magnetic and porous support can improve site accessibility and material handling. However, the benefit of nanomaterials depends strongly on their dispersion, loading amount, compatibility with the polymer matrix, and stability in water. Excessive nanomaterial loading may block recognition sites, increase nonspecific adsorption, or reduce reproducibility. Therefore, high-performance IIP sensors require an optimized balance between imprint-derived selectivity and nanomaterial-assisted signal enhancement (; ; ; Yu et al., 2022).
6 Analytical performance and real-water validation of IIP-Based sensors
6.1 Analytical performance across sensing platforms
Table 2 summarizes the analytical performance of representative IIP-based sensors for toxic metal-ion monitoring in water. Across the reported studies, IIPs consistently enable selective recognition of target ions while achieving low detection limits, wide linear ranges, and acceptable recoveries in environmental samples. However, analytical performance varies significantly across sensing platforms and device architectures. These differences arise not only from the transduction mechanism but also from the imprinting chemistry, the accessibility of binding sites in aqueous media, and the extent to which nanomaterials enhance charge transfer and mass transport within the sensing interface.
TABLE 2
| Target ion | Platform/Method | Nanomaterial | LOD (M) | Linear range (M) | Response time | Real water matrix | Recovery (%) | Performance assessment | Ref. |
|---|---|---|---|---|---|---|---|---|---|
| Ag+ | Electrochemical (DPSV) CPE/IIP | MWCNTs | 1.2 Ć 10ā10 | 5.0 Ć 10ā10ā2.8 Ć 10ā7 | 3ā4Ā min | Tap, surface, groundwater | 97ā101 | Very low LOD; rapid response; good recovery; validated in several matrices | Zhiani et al. (2016) |
| Hg2+ | Electrochemical (SWASV) GCE/IIP | rGO | 9.97 Ć 10ā11 | 3.49 Ć 10ā10ā3.99 Ć 10ā7 | ā¼14Ā min | Tap, river, wastewater | 97ā103 | Very low LOD; good recovery; validated in complex wastewater matrix | |
| Cd2+ | Electrochemical (DPASV) CPE/IIP | ā | 1.33 Ć 10ā9 | 4.45 Ć 10-9ā3.56 Ć 10ā7 | ā¼6Ā min | River, dam, tap | 97ā102 | Low LOD; good recovery; validated in multiple water matrices | |
| Cd2+ | Optical colorimetric PAD/IIP | ā | 3.56 Ć 10ā9 | 8.90 Ć 10-9ā8.90 Ć 10ā7 | ā¼12Ā min | Tap, lake, river | 88ā109 | Portable optical format; acceptable but wider recovery range suggests matrix effects | |
| Pb2+ | Electrochemical (DPV) CPE/IIP | ā | 1.3 Ć 10ā1 | 1.0 Ć 10-9ā7.5 Ć 10ā7 | 2ā3Ā min | Tap, river | 99ā102 | LOD appears inconsistent with linear range; verify original value before submission | |
| Pb2+ | Electrochemical (DPASV) GCE/IIP | MWCNTs | 7.72 Ć 10ā10 | 2.41 Ć 10-9ā1.06 Ć 10ā7 | ā¼21Ā min | Tap, mineral | 95ā103 | Low LOD; good recovery; longer response time than several electrochemical systems | |
| Cu2+ | Potentiometric electrode | GO/MWCNTs | 4.0 Ć 10ā7 | 1.0 Ć 10-6ā1.0 Ć 10ā1 | ā¼3Ā s | Tap, river | 102ā104 | Very fast response; broad linear range; higher LOD than stripping-based sensors | |
| Ni2+ | Electrochemical (DPV) Pt/IIP | MWCNTs | 2.8 Ć 10ā8 | 1.70 Ć 10-5ā8.52 Ć 10ā5 | NR | Industrial wastewater | 99ā99.5 | Validated in industrial wastewater; benchmarking limited because response time is not reported | |
| Cr6+ | Fluorescence sensor | ZnS:Mn QDs | 1.05 Ć 10ā7 | 3.85 Ć 10-7ā1.92 Ć 10ā5 | NR | Tap, lake, wastewater | 94ā107 | Optical platform with acceptable recovery; benchmarking limited by missing response time | Zhang et al. (2019) |
| As3+ | Electrochemical (SWV) GCE/IIP | AuNPs | 2.00 Ć 10ā10 | 1.20 Ć 10ā10ā6.67 Ć 10ā9 | 7ā8Ā min | Drinking, river | 81ā113 | Very low LOD; wider recovery range suggests stronger matrix influence | Yang et al. (2023) |
| Pb2+ | Electrochemical (DPV) GCE/IIP | AuNPs/graphene/MWCNTs | 2.8 Ć 10ā10 | 1.0 Ć 10-9ā1.0 Ć 10ā5 | ā¼10Ā min | Tap, river | 97ā105 | Hybrid nanomaterial system; low LOD; broad working range; good recovery | Wu et al. (2020b) |
| Cd2+ | Chemiresistive sensor IDE/IIP | rGO | 7.38 Ć 10ā9 | 1.78 Ć 10-8ā1.78 Ć 10ā6 | ā¼5Ā min | Tap, lake, river | 94ā114 | Portable electrical detection; rapid response; recovery indicates possible matrix variability | |
| Hg2+ | QCM sensor | ā | 6.98 Ć 10ā8 | 2.14 Ć 10-7ā9.97 Ć 10ā6 | NR | Tap, wastewater | NR | Label-free detection; benchmarking is limited because response time and recovery are not reported | |
| Cd2+ | Optical interferometric sensor | Fe3O4 | 5.1 Ć 10ā11 | 0ā1.0 Ć 10ā6 | 13ā50Ā s | Aqueous samples | NR | Very low LOD and rapid response; real-matrix recovery not reported |
Analytical performance of representative IIP-based sensors for toxic metal-ion detection in water.
DPSV: differential pulse stripping voltammetry, CPE: carbon paste electrode, MWCNTs: multi-walled carbon nanotubes, SWASV: square wave anodic stripping voltammetry, rGO: reduced graphene oxide, DPASV: differential pulse anodic stripping voltammetry, PAD: Paper-based analytical device, DPV: differential pulse voltammetry, Pt: Platinum electrode, Fe3O4: magnetic nanoparticles, GO: graphite oxide, ZnS: zinc sulfide, QDs: Quantum dots, SWV: square wave voltammetry, AuNPs: gold nanoparticles, IDE: interdigitated au electrodes, QCM: quartz crystal microbalance, Ag+: silver(I) ion, As3+: arsenic (III) ion, Cd2+: cadmium (II) ion, Cr3+: chromium (III) ion, Cr6+: chromium (VI) ion, Cu2+: copper (II) ion, Hg2+: mercury (II) ion (mercuric ion), Ni2+: nickel (II) ion, Pb2+: lead (II) ion, NR: not reported., LOD: limit of detection.
A clear trend in Table 2 is the dominance of electrochemical sensing platforms. Techniques such as differential pulse voltammetry, stripping voltammetry, and potentiometric measurements appear most frequently, reflecting the strong compatibility between ion rebinding at the polymer-electrode interface and electrochemical signal generation. In these systems, metal-ion coordination within imprinted cavities perturbs the interfacial charge distribution or redox behavior, allowing highly sensitive detection through established electroanalytical methods.
For widely studied contaminants such as Cd2+, Pb2+, and Hg2+, the strongest analytical performance is typically observed in hybrid architectures combining selective imprinted polymers with conductive nanomaterials, including rGO, ERGO, MWCNTs, AuNPs, or magnetic nanostructures. These materials reduce charge-transfer resistance, expose a greater fraction of imprinted binding sites, and alleviate diffusion limitations associated with dense cross-linked polymer films. In contrast, polymer-only systems frequently exhibit higher detection LODs and slower response times, even when the imprinting chemistry is highly selective. These observations indicate that high-performance IIP sensors typically depend on the synergy between selective coordination chemistry and a conductive, nanostructured transducer interface that remains accessible in aqueous media.
Optical and fluorescence-based sensors also achieve environmentally relevant detection limits, particularly for Pb2+, Cd2+, Cr6+, and Ni2+. Their principal advantage lies in non-electrical readout and compatibility with portable or disposable sensing formats. However, compared with electrochemical sensors, optical systems often exhibit narrower working ranges, longer analysis times, or more limited validation in complex environmental matrices. Optical signals can also be affected by film thickness, background scattering, or matrix-dependent attenuation, which can reduce analytical robustness in natural waters.
For less frequently studied ions such as Ag+, As3+, Cr3+, and Ni2+, the available performance data remain relatively limited. In these cases, aqueous speciation, redox chemistry, hydrolysis, and strong hydration effects may exert greater influence on analytical performance than in the extensively studied Cd2+ and Pb2+ systems. Expanding sensor development toward these environmentally relevant metals will require greater attention to both imprinting chemistry and matrix-dependent metal speciation.
The main factors affecting analytical performance can be grouped into four categories: imprinting-related, transport-related, transducer-related, and matrix-related factors. Imprinting-related factors include ligand type, cavity fidelity, template-removal efficiency, binding-site density, and the strength of metalāligand coordination. Transport-related factors include polymer thickness, porosity, swelling behavior, and accessibility of hydrated ions to the recognition sites. Transducer-related factors include electrode conductivity, optical signal stability, piezoelectric mass sensitivity, and the efficiency of signal amplification. Matrix-related factors include pH, ionic strength, dissolved organic matter, competing ions, suspended particles, and fouling species. These factors explain why sensors designed for the same target ion can show different detection limits, response times, linear ranges, and recoveries. Therefore, analytical performance should be interpreted as the combined outcome of imprinting chemistry, material architecture, transducer design, and environmental matrix (; ).
A broader conclusion from Table 2 is that direct comparison between studies remains challenging because analytical conditions and reporting practices are not standardized. Parameters such as response time, operational stability, regeneration cycles, and selectivity testing are reported inconsistently, and real-sample validation frequently relies on spiked matrices rather than blind environmental samples. In addition, many studies do not clearly distinguish between total metal concentration and the free-ion fraction that is actually recognized by imprinted binding sites in aqueous solution. Consequently, although IIP-based sensors can achieve LODs approaching regulatory requirements for several priority toxic metal ions, more uniform benchmarking protocols will be necessary to enable meaningful cross-platform comparisons and guide further technological development. Overall, electrochemical IIP sensors currently provide the best balance of sensitivity, speed, and matrix compatibility, whereas optical and piezoelectric formats offer complementary advantages in portability, label-free operation, or simplified readout.
Comparison across sensing platforms shows that electrochemical IIP sensors generally provide the strongest analytical performance for trace toxic metal-ion detection because they combine selective ion rebinding with sensitive current-, potential-, or impedance-based readout. Hybrid electrochemical systems containing conductive nanomaterials frequently achieve lower LODs than polymer-only sensors because nanomaterials improve electron transfer, increase electroactive area, and reduce diffusion limitations. Optical and fluorescence-based IIP sensors also achieve environmentally relevant LODs and offer advantages in simple readout and portability, but their performance may be more sensitive to optical background, turbidity, and matrix-induced quenching. Piezoelectric sensors provide label-free detection, but their use remains more limited because frequency responses depend strongly on film adhesion, swelling behavior, and mechanical stability. Overall, the data indicates that electrochemical platforms are currently the most mature for quantitative detection, while optical and piezoelectric formats remain valuable complementary approaches for simplified or label-free monitoring (; ; ).
6.2 Validation in real water matrices
While analytical metrics provide an indication of intrinsic sensor performance, validation in real water matrices is essential for assessing practical applicability. Natural waters contain variable ionic strength, hardness ions, dissolved organic matter (DOM), suspended particulates, and competing trace metals that influence metal speciation and sensor response. These matrix components may reduce the free-ion fraction available for rebinding at imprinted cavities or block access to recognition sites through nonspecific adsorption. As a result, successful validation in real samples provides both analytical confirmation and an indication that the coordination chemistry and structural accessibility of the imprinted cavities remain effective under environmentally relevant conditions (; ; ; ; ; ; ).
Table 3 provides a practical comparison of IIP-based sensors by linking real-water validation with LOD, recovery, matrix effects, and sensor applicability. Most reported platforms showed recoveries within or close to the acceptable analytical range, confirming the applicability of IIP-based sensors in diverse water samples, including tap, mineral, river, lake, wastewater, and industrial wastewater. However, wider recovery ranges, such as 81%ā113% for As3+ and 88%ā109% for colorimetric Cd2+ detection, indicate stronger matrix effects and the need for careful real-sample validation. Matrix components such as dissolved organic matter, competing ions, salinity, chloride complexation, turbidity, fouling, optical background, and fluorescence quenching can affect free-ion availability and signal stability. Overall, electrochemical IIP sensors appear particularly suitable for quantitative monitoring, while optical, fluorescence, and paper-based platforms offer advantages for portable or multiplexed screening but require careful control of matrix-related interferences.
TABLE 3
| Metal ion | Platform | Validated matrices | LOD (M) | Recovery (%) | Reported/Expected matrix effects | Practical interpretation | Ref |
|---|---|---|---|---|---|---|---|
| Ag+ | Electrochemical DPSV CPE/IIP with MWCNTs | Tap, surface, groundwater | 1.2 Ć 10ā10 | 97ā101 | Low-to-moderate matrix complexity | Suitable for routine water screening | Zhiani et al. (2016) |
| Hg2+ | Electrochemical SWASV GCE/IIP with rGO | Tap, river, wastewater | 9.97 Ć 10ā11 | 97ā103 | Organic matter and competing ions may affect the response | Promising for polluted water monitoring | |
| Cd2+ | Electrochemical DPASV CPE/IIP | River, dam, tap | 1.33 Ć 10ā9 | 97ā102 | Moderate matrix influence expected in natural waters | Applicable to routine Cd2+ monitoring | |
| Cd2+ | Optical colorimetric PAD/IIP | Tap, lake, river | 3.56 Ć 10ā9 | 88ā109 | Optical background and water composition may affect colorimetric response | Useful for portable screening | |
| Pb2+ | Electrochemical DPASV GCE/IIP with MWCNTs | Tap, mineral water | 7.72 Ć 10ā10 | 95ā103 | Moderate matrix influence in potable water | Good applicability in drinking-water analysis | |
| Cu2+ | Potentiometric GO/MWCNT electrode | Tap, river | 4.0 Ć 10ā7 | 102ā104 | Competing divalent ions may influence the potentiometric response | Rapid detection, but selectivity must be verified | |
| Ni2+ | Electrochemical DPV Pt/IIP with MWCNTs | Lake and industrial wastewater | 2.8 Ć 10ā8 | 99ā99.5 | Complex wastewater composition may affect ion availability | Relevant for industrial effluent monitoring | |
| Cr3+ | DPV Pt/MWCNT-IIP | Industrial wastewater | 5.0 Ć 10ā8 | NR | Cr3+ hydrolysis near neutral pH and complex industrial-wastewater composition may affect free-ion availability | Useful for Cr3+ sensing/extraction in industrial wastewater, but pH/speciation control is important | |
| Cr6+ | Fluorescence sensor with ZnS:Mn QDs | Tap, lake, wastewater | 1.05 Ć 10ā7 | 94ā107 | Fluorescence may be affected by quenching and background signal | Suitable when optical matrix effects are controlled | Zhang et al. (2019) |
| As3+ | Electrochemical SWV GCE/IIP with AuNPs | Drinking, river | 2.00 Ć 10ā10 | 81ā113 | Wider recovery range indicates stronger matrix effects | Requires careful matrix validation | Yang et al. (2023) |
| Cd2+/Pb2+ | Fluorescence QD-based IIP | Surface water, drinking water, seawater | 2.18 Ć 10ā9/1.62 Ć 10ā9 | NR | Salinity and optical background may affect fluorescence | Demonstrates multi-metal detection feasibility | Zhou et al. (2020) |
| Cd2+/Cu2+/Hg2+/Pb2+ | Paper-based microfluidic fluorescence device | Seawater | 3.49 Ć 10ā11ā2.36 Ć 10ā10 | NR | High ionic strength and chloride complexation are critical | Useful for complex saline waters if validated |
Real-water validation and matrix effects of representative IIP-based toxic metal-ion sensors.
LOD: limit of detection, DPSV: differential pulse stripping voltammetr, SWASV: square-wave anodic stripping voltammetry, DPASV: differential pulse anodic stripping voltammetry, SWV: square-wave voltammetry, DPV: differential pulse voltammetry, CPE: carbon paste electrode, GCE: glassy carbon electrode, Pt: platinum, IIP: ion-imprinted polymer, MWCNTs: multi-walled carbon nanotubes, rGO: reduced graphene oxide, GO: graphene oxide, PAD: paper-based analytical device, QDs/QD: quantum dots/quantum dot, AuNPs: gold nanoparticles, NR: not reported, Ag+: silver(I) ion, As3+: arsenic (III) ion, Cd2+: cadmium (II) ion, Cr6+: chromium (VI) ion, Cr3+: chromium (III), Cu2+: copper (II) ion, Hg2+: mercury (II) ion, Ni2+: nickel (II) ion, Pb2+: lead (II) ion.
6.3 Drinking and surface waters
Tap and drinking waters represent the most common validation matrices for IIP sensors because their moderate ionic composition provides a practical intermediate between laboratory buffers and more chemically complex environmental waters. Several studies demonstrate that electrochemical IIP sensors can maintain selective recognition of target ions under these conditions. For example, Pb2+ determination in tap and mineral water using composite IIP electrodes shows strong selectivity against common divalent cations and satisfactory recoveries, indicating that the imprinted coordination cavities remain stable in typical potable-water chemistries (; ; Wu et al., 2020b). Similarly, Hg2+ sensors employing carbon-paste or nanocarbon-modified electrodes have demonstrated trace-level sensitivity in tap-water samples ().
Surface waters introduce additional complexity due to dissolved organic matter, suspended particles, and fluctuating redox conditions that influence metal speciation and bioavailability. Organic ligands present in DOM can strongly complex metals such as Cd2+ and Pb2+, reducing the free-ion concentration available for binding to imprinted sites. Studies using graphene-assisted electrochemical IIP sensors for Cd2+ detection in river and lake samples illustrate how conductive nanostructures can partially compensate for these challenges by improving mass transport and maintaining access to surface-imprinted binding sites (; ). Nevertheless, practical measurements often require pH adjustment or electrode cleaning to mitigate fouling and maintain reproducible signals.
6.4 Seawater and industrial wastewater
Seawater and industrial effluents represent the most chemically demanding environments for IIP sensors. In seawater, high ionic strength and elevated chloride concentrations intensify competitive binding and destabilize electrochemical baselines. Under such conditions, both the accessibility of the imprinted sites and the conductivity of the sensing interface become critical. One example is a microfluidic paper-based analytical device capable of simultaneously detecting Cu2+, Cd2+, Pb2+, and Hg2+ in coastal seawater using integrated on-chip enrichment (). This approach demonstrates how imprinting selectivity can be combined with microfluidic sample handling to maintain sensitivity in highly saline environments.
Industrial wastewater and effluents introduce additional analytical challenges because they may contain high concentrations of organic contaminants, extreme pH conditions, and mixtures of multiple toxic metal ions that compete for coordination sites within the polymer network. Detection of Cr3+ in electroplating wastewater illustrates that carefully designed imprinted interfaces can retain selective binding in strongly competitive environments when solution speciation and pH conditions are properly controlled (; ). Similarly, Hg2+ sensors validated in industrial waters, often involving diluted or pretreated samples highlight the importance of regeneration procedures and sample preparation strategies for maintaining stable analytical signals in fouling-prone matrices ().
6.5 Overall assessment of matrix effects
Across the studies summarized in Tables 2, 3, a consistent trend emerges: the analytical performance of IIP-based sensors is strongly influenced by the chemical environment in which they operate. In relatively simple matrices such as drinking water, sensor performance is largely governed by the intrinsic selectivity of the imprinted coordination sites. As matrix complexity increases toward surface waters, seawater, and industrial effluents, additional factors, including metal speciation, ionic competition, surface fouling, and signal stability, become increasingly important.
Successful strategies for maintaining analytical performance in complex waters include surface imprinting, conductive nanomaterial scaffolds, antifouling interfaces, and integrated enrichment or regeneration protocols. However, many studies still rely primarily on buffer solutions or spiked matrices rather than fully representative environmental samples. Greater emphasis on rigorous real-matrix validation and standardized performance reporting will therefore be essential for translating promising laboratory-scale IIP sensors into reliable field-deployable technologies for environmental toxic metal-ion monitoring (; ; ; ; ; ; ).
7 Perspectives: advantages, limitations, and future directions
IIP sensors provide a chemically rational platform for selective toxic metal-ion monitoring because imprinting generates binding cavities whose geometry, charge distribution, and coordination environment are complementary to the template ion. These sites mimic metal-ligand interactions in solutions and enable selective recognition even in the presence of competing species, addressing a key limitation of purely electrochemical detection based only on potential control (). When coupled with electrochemical transduction, particularly stripping voltammetry, impedance spectroscopy, or potentiometry, the imprinted layer can also function as a selective enrichment interface, enabling trace and sub-trace detection with portable platforms (; ).
A major advantage of IIP systems is their chemical robustness and architectural versatility. Unlike biological receptors, imprinted polymers generally tolerate broader pH ranges and harsher regeneration conditions while maintaining structural integrit (; ). Their chemistry is adaptable to particle-based composites, drop-cast layers, and electropolymerized thin films, and performance is often enhanced by hybridization with conductive nanomaterials that improve charge transfer and mass transport without replacing imprint-derived selectivity (; ). These features explain why many IIP sensors show acceptable recoveries in tap water, river water, seawater, and industrial wastewater (; ).
Despite these advantages, several limitations still restrict broader deployment. Recognition-site instability can arise when coordinating ligands are physically entrapped rather than covalently incorporated, leading to ligand leaching and gradual loss of selectivity during template removal or repeated operation (; ). Dense or highly cross-linked films can also bury binding sites and slow diffusion of hydrated ions, whereas excessively thick coatings reintroduce mass-transfer limitations even in surface-imprinted formats (). In addition, many imprinted polymers are intrinsically nonconductive, so electrochemical performance often depends on conductive additives whose benefits vary with porosity, hydrophilicity, dispersion quality, and coupling to the electrode surface (; Zarejousheghani et al., 2021). Fabrication reproducibility remains another challenge because polymerization conditions, template extraction efficiency, and film deposition strongly affect site density, accessibility, and interfacial stability (; ).
Future development of IIP-based toxic metal-ion sensors should focus on improving the relationship between recognition chemistry, interfacial architecture, and real-sample performance. From a mechanistic perspective, stronger and more selective coordination motifs, including multidentate or mixed-donor monomers, could improve cavity fidelity and binding affinity for target ions. From a structural perspective, surface-imprinted layers, ultrathin electropolymerized films, and porous nanostructured supports can increase the accessibility of recognition sites and shorten diffusion pathways. From a transduction perspective, conductive and optically active nanomaterials should be optimized to enhance signal generation without blocking imprinted cavities or increasing nonspecific adsorption. In addition, future studies should place greater emphasis on reproducibility, regeneration, long-term stability, antifouling behavior, and validation in authentic environmental samples rather than only spiked laboratory matrices. Standardized benchmarking against conventional methods such as ICP-MS, ICP-OES, or AAS will also be essential to define the practical role of IIP sensors as complementary tools for rapid screening and field monitoring (; ; ; ).
Also, future progress will require advances in both polymer chemistry and device engineering. Stronger and more selective coordination motifs, including multidentate or mixed-donor monomers, may improve binding strength and cavity fidelity, while surface-imprinting and controlled electropolymerization can enhance accessibility and reproducibility. Greater emphasis is also needed on realistic validation and standardized benchmarking in authentic environmental waters, including long-term durability, regeneration, fouling resistance, and comparison with reference analytical methods. With continued progress in imprinting chemistry, interfacial design, and validation rigor, IIP-based sensors are well-positioned to complement established laboratory techniques and support rapid, on-site water-quality monitoring in environmental and industrial settings. As water-quality monitoring increasingly shifts toward decentralized sensing and real-time environmental surveillance, imprint-based recognition strategies may play an important role in bridging laboratory analytical chemistry with deployable field diagnostics.
8 Conclusion
This review highlights the principles of IIPs and their application in sensing platforms for toxic metal-ion detection in water. Imprinting creates binding cavities whose coordination geometry, charge distribution, and size complement the target ion, enabling selective recognition even in the presence of competing species. Among reported systems, electrochemical IIP sensors dominate because they effectively combine selective metal uptake with sensitive signal transduction. Voltammetric platforms particularly benefit from the preconcentration capability of imprinted layers, while conductive nanomaterials often enhance electron transfer and mass transport, enabling trace-level detection in diverse water matrices, including tap water, surface waters, seawater, and industrial effluents. Optical, fluorescence, and piezoelectric approaches further demonstrate the versatility of imprint-based recognition, though they may be more susceptible to matrix effects such as turbidity and surface fouling.
This coordination-defined recognition is central to IIP performance because the choice of functional monomer, donor atoms, ligand denticity, and templateāmonomer complex stability determines the fidelity, accessibility, and reversibility of the final binding sites.
Despite these advances, several challenges still limit widespread environmental deployment. Diffusion constraints within dense polymer networks can reduce site accessibility, while incomplete template removal or weak ligand immobilization may affect long-term selectivity and reproducibility. Environmental matrices containing competing ions, dissolved organic matter, and fouling species can further complicate sensor performance. Addressing these issues will require improved imprinting chemistries, surface-imprinted or ultrathin films with controlled thickness, and antifouling interface designs. Equally important is the adoption of standardized benchmarking and validation of analytical methods in authentic environmental waters against established standards. With continued advances in polymer chemistry, interfacial engineering, and portable sensing technologies, IIP-based sensors are well-positioned to complement conventional laboratory techniques and enable reliable on-site monitoring of water quality.
Statements
Author contributions
GY: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Validation, Visualization, Writing ā original draft. GS: Conceptualization, Funding acquisition, Project administration, Resources, Supervision, Visualization, Writing ā review and editing.
Funding
The author(s) declared that financial support was not received for this work and/or its publication.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was used in the creation of this manuscript. AI was used to recreate all images to improve resolution.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisherās note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
AbdelmonemB. H.KamalL. T.ElbazR. M.KhalifaM. R.AbdelnaserA. (2025). From contamination to detection: the growing threat of heavy metals. Heliyon11 (Number 1), e41713. 10.1016/j.heliyon.2025.e41713
2
Abdul HalimA.SulaimanS. S.NordinA. N.Bajunaid HarizH. (2024). Systematic review study on application of ion imprinted polymer (IIP) in heavy metals detection. Int. J. Environ. Anal. Chem.104 (16), 4470ā4494. 10.1080/03067319.2022.2106426
3
AdhawiyahR. E.LeeJ. (2026). Nanomaterial-enhanced sensors for trace heavy metal ion detection: a review of electrochemical and optical methods. Micro Nano Syst. Lett.14 (1), 4. 10.1186/s40486-026-00256-6
4
AhmadA.BhattacharyaP. (2019). Arsenic in drinking water: is 10 μg/L a safe limit?Curr. Pollut. Rep.5 (1), 1ā3. 10.1007/s40726-019-0102-7
5
AhmadO. S.BedwellT. S.EsenC.Garcia-CruzA.PiletskyS. A. (2019). Molecularly imprinted polymers in electrochemical and optical sensors. Trends Biotechnol.37 (3), 294ā309. 10.1016/j.tibtech.2018.08.009
6
Ait LahcenA.LamaouiA.AmineA. (2023). Exploring the potential of molecularly imprinted polymers and metal/metal oxide nanoparticles in sensors: recent advancements and prospects. Microchim. Acta190 (12), 497. 10.1007/s00604-023-06030-4
7
Ait-TouchenteZ.SakhraouiH. E. E. Y.FouratiN.ZerroukiC.MaoucheN.YaakoubiN.et al (2020). High performance zinc oxide nanorod-doped ion imprinted polypyrrole for the selective electrosensing of Mercury ii ions. Appl. Sci. Switz.10 (19), 1ā22. 10.3390/app10197010
8
AlizadehT.HamidiN.GanjaliM. R.RafieiF. (2018). Determination of subnanomolar levels of Mercury (II) by using a graphite paste electrode modified with MWCNTs and Hg(II)-imprinted polymer nanoparticles. Microchim. Acta185 (1), 16. 10.1007/s00604-017-2534-3
9
AnimashaunC.SlaughterG. (2025). Molecular imprinting and nanomaterial synergy for lactate detection. Biosens. Bioelectron. X26, 100659. 10.1016/j.biosx.2025.100659
10
AravindA.MathewB. (2018). Electrochemical sensor based on nanostructured ion imprinted polymer for the sensing and extraction of Cr(III) ions from industrial wastewater. Polym. Int.67 (12), 1595ā1604. 10.1002/pi.5683
11
AravindA.MathewB. (2019). An electrochemical sensor and sorbent based on mutiwalled carbon nanotube supported ion imprinting technique for Ni(II) ion from electroplating and steel industries. SN Appl. Sci.1 (1), 23. 10.1007/s42452-018-0018-7
12
ArdalaniM.ShamsipurM.Besharati-SeidaniA. (2020). A new generation of highly sensitive potentiometric sensors based on ion imprinted polymeric nanoparticles/multiwall carbon nanotubes/polyaniline/graphite electrode for sub-nanomolar detection of lead(II) ions. J. Electroanal. Chem.879, 114788. 10.1016/j.jelechem.2020.114788
13
BakhshpourM.DenizliA. (2020). Highly sensitive detection of Cd(II) ions using ion-imprinted surface plasmon resonance sensors. Microchem. J.159, 105572. 10.1016/j.microc.2020.105572
14
BehbahaniM.BagheriA.TaghizadehM.SalarianM.SadeghiO.AdlnasabL.et al (2013). Synthesis and characterisation of nano structure lead (II) ion-imprinted polymer as a new sorbent for selective extraction and preconcentration of ultra trace amounts of lead ions from vegetables, rice, and fish samples. Food Chem.138 (3), 2050ā2056. 10.1016/j.foodchem.2012.11.042
15
BjĆørklundG.DadarM.MutterJ.AasethJ. (2017). The toxicology of Mercury: current research and emerging trends. Environ. Res.159, 545ā554. 10.1016/j.envres.2017.08.051
16
Blaszczak-BoxeC. S.KarleN. N.WangS.YuM.GolosovN.RiyadM.et al (2023). Environmental assessment and monitoring of heavy metals in New York City potable water systems: case study at medgar evers college, correlation analysis, and public health impacts. WaterSwitzerl.15 (24), 4233. 10.3390/w15244233
17
BoontanonS. K.ChuiprasertJ.SrinivesS.BoontanonN.PolprasertC.RamungulN.et al (2023). Electrochemical sensor based on a composite of reduced graphene oxide and molecularly imprinted copolymer of PolyanilineāPoly(o-phenylenediamine) for ciprofloxacin determination: fabrication, characterization, and performance evaluation. ACS Omega8 (2), 2564ā2574. 10.1021/ACSOMEGA.2C07095
18
CajamarcaF. A.TarleyC. R. T. (2022). Influence of synthesis parameters and polymerization methods on the selective and adsorptive performance of bio-inspired ion imprinted polymers. Separations9 (10), 266. 10.3390/separations9100266
19
ChaeH. S.KimS. D.PiaoS. H.ChoiH. J. (2016). Core-shell structured Fe3O4@SiO2 nanoparticles fabricated by solāgel method and their magnetorheology. Colloid Polym. Sci.294 (4), 647ā655. 10.1007/s00396-015-3818-y
20
ChaudharyV.SharmaS. (2019). āSuspension polymerization technique: parameters affecting polymer properties and application in oxidation reactions,āJ. Polym. Res.26. Netherlands. 10.1007/s10965-019-1767-8
21
ChenL.XuS.LiJ. (2011). Recent advances in molecular imprinting technology: current status, challenges and highlighted applications. Chem. Soc. Rev.40 (5), 2922ā2942. 10.1039/c0cs00084a
22
ChenJ. S.LiM.CotletM. (2019). Nanoscale photoinduced charge transfer with individual quantum dots: tunability through synthesis, interface design, and interaction with charge traps. ACS Omega4 (5), 9102ā9112. 10.1021/acsomega.9b00803
23
CostaM.Di MasiS.Garcia-CruzA.PiletskyS. A.MalitestaC. (2023). Disposable electrochemical sensor based on ion imprinted polymeric receptor for Cd(II) ion monitoring in waters. Sensors Actuators B Chem.383, 133559. 10.1016/j.snb.2023.133559
24
CulverH. R.PeppasN. A. (2017). Protein-imprinted polymers: the shape of things to come?Chem. Mater.29 (14), 5753ā5761. 10.1021/acs.chemmater.7b01936
25
De AchaN.ElosĆŗaC.CorresJ. M.ArreguiF. J. (2019). Fluorescent sensors for the detection of heavy metal ions in aqueous media. Sensors Switz.19 (3). 10.3390/s19030599
26
Di MasiS.PennettaA.GuerreiroA.CanfarottaF.De BenedettoG. E.MalitestaC. (2020). Sensor based on electrosynthesised imprinted polymeric film for rapid and trace detection of copper(II) ions. Sensors Actuators, B Chem.307, 127648. 10.1016/j.snb.2019.127648
27
DiltemizS. E.KeƧiliR.ErsƶzA.SayR. (2017). Molecular imprinting technology in Quartz Crystal Microbalance (QCM) sensors. Sensors Switz.17 (3). 10.3390/s17030454
28
DingJ.KraisS.LiZ.TriebskornR.KƶhlerH. R. (2025). Multi- and transgenerational effects of silver ions (ag+) in the ng/L range on life cycle parameters and population growth of the midge Chironomus riparius (diptera, chironomidae). Toxics13 (10), 855. 10.3390/toxics13100855
29
DongJ.ZhangY.HussainM. I.ZhouW.ChenY.WangL. N. (2022). G-c3 n4: properties, pore modifications, and photocatalytic applications. Nanomaterials12 (1), 121. 10.3390/nano12010121
30
ErdemƶzgecanSaylanY.AndaƧM.DenizliA. (2018). Molecularly imprinted polymers for removal of metal ions: an alternative treatment method. Biomimetics3 (4). 10.3390/biomimetics3040038
31
FadillahG.Nurdina InayatussholehaE.Anindya MukaromN.Sanditya RattyanandaB.Prio WicaksonoW.FatimahI.et al (2022). Ion imprinted-carbon paste electrode as electrochemical sensor for ultra-trace recognizing speciation of Mercury. Results Chem.4, 100489. 10.1016/j.rechem.2022.100489
32
FafaS.ZazouaA. (2024). A new electrochemical sensor based on a screen-printed electrode modified with an ion-imprinted PEDOT for the detection and the quantification of Cd(II). Microchem. J.204, 110977. 10.1016/j.microc.2024.110977
33
FaysalA.AlDorrehS.KayaB. S.GƶlcüA. (2025). Molecularly imprinted electrochemical sensors for halogenated Anti-Infective agent detection: a review of current developments and prospects. ACS Omega10 (32), 35327ā35351. 10.1021/acsomega.5c03269
34
FeldmannJ.SalaünP.LombiE. (2009). Critical review perspective: elemental speciation analysis methods in environmental chemistry-moving towards methodological integration. Environ. Chem.6 (Number 4), 275ā289. 10.1071/EN09018
35
FitzgeraldD. J. (1998). Safety guidelines for copper in water. Am. J. Clin. Nutr.67 (5), 1102. 10.1093/ajcn/67.5.1098S
36
FuK.SunH.ChenX.CaoY.LiuL.ZhaoJ.et al (2025). Computer-aided design and construction of a novel electro-responsive ion-imprinted sensor for the individual/simultaneous detection of Cd(II) and Pb(II) in water environments. Food Chem.465, 142052. 10.1016/j.foodchem.2024.142052
37
GanjaliM. R.RahmaniA. R.ShokoohiR.FarmanyA.KhazaeiM. (2019). A highly sensitive and selective electrochemical mercury(II) sensor based on nanoparticles of Hg(II)-imprinted polymer and graphitic carbon nitride (g-C3N4). Int. J. Electrochem. Sci.14 (7), 6420ā6430. 10.20964/2019.07.80
38
GarciĆ”-Miranda FerrariA.CarringtonP.Rowley-NealeS. J.BanksC. E. (2020). Recent advances in portable heavy metal electrochemical sensing platforms. Environ. Sci. Water Res. Technol.6 (10), 2676ā2690. 10.1039/d0ew00407c
39
GengY.LiuY.SongL.WuJ.FuP.ZhaoW.et al (2026). Research progress of micro-mixing technologies in microfluidic chips and their applications in heavy metal detection in seawater: a review. Thalassas42 (2), 101. 10.1007/s41208-026-01102-7
40
Ghanei-MotlaghM.TaherM. A. (2017). Novel imprinted polymeric nanoparticles prepared by solāgel technique for electrochemical detection of toxic cadmium(II) ions. Chem. Eng. J.327, 135ā141. 10.1016/j.cej.2017.06.091
41
Ghanei-MotlaghM.TaherM. A.HeydariA.Ghanei-MotlaghR.GuptaV. K. (2016). A novel voltammetric sensor for sensitive detection of mercury(II) ions using glassy carbon electrode modified with graphene-based ion imprinted polymer. Mater. Sci. Eng. C63, 367ā375. 10.1016/j.msec.2016.03.005
42
GongS.LiangY.LiuX.GaoH.LiaoH.LinX.et al (2023). Advancing selective copper detection in water: innovative electrode utilizing surface ion-imprinted polymer. Appl. Surf. Sci. Adv.18, 100514. 10.1016/j.apsadv.2023.100514
43
GoyalA. K.NigamA. (2025). Sensors for toxic metal ion detection in aquatic environment: current status and future perspectives. Discov. Appl. Sci.7 (12), 1405. 10.1007/s42452-025-07936-9
44
GuadaƱo-SĆ”nchezM.Navarro-VillosladaF.Delgado-SoriaG.MarcoJ. F.Saura-MuzquizM.Ćlvaro-GómezL.et al (2024). Fast and straightforward synthesis in molecular imprinting: core-shell polymerization of magnetic imprinted polymers by microwave induction. ACS Appl. Polym. Mater.6 (6), 3243ā3252. 10.1021/acsapm.3c03068
45
HanD.ZhaoN.CuiY.YanH. (2024). Molecularly imprinted polymers meet sensors: insights and prospects for pollutants analysis. TrAC - Trends Anal. Chem.181, 118032. 10.1016/j.trac.2024.118032
46
HandeP. E.SamuiA. B.KulkarniP. S. (2015). Highly selective monitoring of metals by using ion-imprinted polymers. Environ. Sci. Pollut. Res.22 (10), 7375ā7404. 10.1007/s11356-014-3937-x
47
HossiniH.ShafieB.NiriA. D.NazariM.EsfahlanA. J.AhmadpourM.et al (2022). A comprehensive review on human health effects of chromium: insights on induced toxicity. Environ. Sci. Pollut. Res.29 (47), 70686ā70705. 10.1007/s11356-022-22705-6
48
HuS.XiongX.HuangS.LaiX. (2016). Preparation of Pb(II) ion imprinted polymer and its application as the interface of an electrochemical sensor for trace lead determination english, tran. Anal. Sci.32 (9), 850ā975. 10.2116/analsci.32.975
49
HuS.GaoG.LiuY.HuJ.SongY.ZouX. (2019). An electrochemical sensor based on ion imprinted PPy/rGO composite for Cd(II) determination in water. Int. J. Electrochem. Sci.14 (2019), 11714ā11730. 10.20964/2019.11.56
50
HuJ.SedkiM.ShenY.MulchandaniA.GaoG. (2021). Chemiresistor sensor based on ion-imprinted polymer (IIP)-Functionalized rGO for Cd(II) ions in water. Sensors Actuators, B Chem.346, 130474. 10.1016/j.snb.2021.130474
51
HuY.LiuJ.LiuB.LiuD.HuY.WuQ.et al (2024). Detection of heavy metal ions with ion imprinting microfiber sensor arrays. IEEE Sensors J.24 (21), 34462ā34470. 10.1109/JSEN.2024.3453430
52
HuangK.ChenY.ZhouF.ZhaoX.LiuJ.MeiS.et al (2017). Integrated ion imprinted polymers-paper composites for selective and sensitive detection of Cd(II) ions. J. Hazard. Mater.333, 137ā143. 10.1016/j.jhazmat.2017.03.035
53
HuangX.XiaL.LiG. (2023). Recent progress of molecularly imprinted optical sensors. Chemosensors (Vol. 11, 168, 3). 10.3390/chemosensors11030168
54
IslamM. S.BanikS.CollinsonM. M. (2023). Recent advances in bimetallic nanoporous gold electrodes for electrochemical sensing. Nanomaterials13 (18), 2515. 10.3390/nano13182515
55
JhaB. K.YoonJ. C.JangJ. H. (2025). 3D graphene for energy technologies: chemical strategies and industrial challenges. Accounts Mater. Res.6 (7), 799ā813. 10.1021/accountsmr.4c00381
56
JiÅĆÄkovĆ”A.JankovskýO.SoferZ.SedmidubskýD. (2022). Synthesis and applications of graphene oxide. Materials15 (3), 920. 10.3390/ma15030920
57
JoseJ.PrakashP.JeyaprabhaB.AbrahamR.MathewR. M.ZachariaE. S.et al (2023). Principle, design, strategies, and future perspectives of heavy metal ion detection using carbon nanomaterial-based electrochemical sensors: a review. J. Iran. Chem. Soc.20 (4), 775ā791. 10.1007/s13738-022-02730-5
58
KanellisV. G. (2018). Sensitivity limits of biosensors used for the detection of metals in drinking water. Biophys. Rev.10 (5), 1415ā1426. 10.1007/s12551-018-0457-9
59
KaraouzasI.KapetanakiN.MentzafouA.KanellopoulosT. D.SkoulikidisN. (2021). Heavy metal contamination status in Greek surface waters: a review with application and evaluation of pollution indices. Chemosphere263, 128192. 10.1016/j.chemosphere.2020.128192
60
KarnwalA.Kumar SachanR. S.DevgonI.DevgonJ.PantG.PanchpuriM.et al (2024). Gold nanoparticles in nanobiotechnology: from synthesis to biosensing applications. ACS Omega9 (28), 29966ā29982. 10.1021/acsomega.3c10352
61
LahcenA. A.AmineA. (2019). Recent advances in electrochemical sensors based on molecularly imprinted polymers and nanomaterials. Electroanalysis31 (2), 188ā201. 10.1002/elan.201800623
62
LahcenA. A.SlaughterG. (2025). An electrochemical sensor for tenofovir monitoring. Adv. NanoBiomed Res.5 (10), 2500097. 10.1002/anbr.202500097
63
LazarM. M.GhiorghitaC. A.DraganE. S.HumelnicuD.DinuM. V. (2023). Ion-imprinted polymeric materials for selective adsorption of heavy metal ions from aqueous solution. Molecules28 (6), 2798. 10.3390/molecules28062798
64
LiL.ZhuF.LuY.GuanJ. (2018). Synthesis, adsorption and selectivity of inverse emulsion Cd(II) imprinted polymers. Chin. J. Chem. Eng.26 (3), 494ā500. 10.1016/j.cjche.2017.08.014
65
LiY.WangC.ZhaoJ.LiuX.MaM.GaoA.et al (2025). A systematic review of separation/preconcentration and detection techniques for speciation analysis of arsenic and selenium in water. Anal. Methods17 (28), 5807ā5830. 10.1039/d5ay00626k
66
LiuY.ChangX.YangD.GuoY.MengS. (2005). Highly selective determination of inorganic mercury(II) after preconcentration with Hg(II)-imprinted diazoaminobenzene-vinylpyridine copolymers. Anal. Chim. Acta538 (2), 85ā91. 10.1016/j.aca.2005.02.017
67
LowK. M.LinX.WuH.LiS. F. Y. (2024). Ion-imprinted polymer-based sensor for the detection of mercury ions. Polymers16 (5), 652. 10.3390/polym16050652
68
LuoX.HuangW.ShiQ.XuW.LuanY.YangY.et al (2017). Electrochemical sensor based on lead ion-imprinted polymer particles for ultra-trace determination of lead ions in different real samples. RSC Adv.7 (26), 16033ā16040. 10.1039/c6ra25791g
69
MaW.ChangQ.ZhaoJ.YeB. C. (2020). Novel electrochemical sensing platform based on ion imprinted polymer with nanoporous gold for ultrasensitive and selective determination of As3+. Microchim. Acta187 (10), 571. 10.1007/s00604-020-04552-9
70
MachM. H.NottB.ScottJ. W.MaddaloneR. F.WhiddonN. T. (1996). Metal Speciation: Survey of Environmental Methods of Analysis.
71
MaedaM.BartschR. A. (1998). Molecular and Ionic Recognition with Imprinted Polymers: A Brief Overview. 10.1021/bk-1998-0703.ch001
72
MalitestaC.Di MasiS.MazzottaE. (2017). From electrochemical biosensors to biomimetic sensors based on molecularly imprinted polymers in environmental determination of heavy metals. Front. Chem.547. 10.3389/fchem.2017.00047
73
MeoucheW.LaatikainenK.MargaillanA.SilvonenT.SirenH.SainioT.et al (2017). Effect of porogen solvent on the properties of nickel ion imprinted polymer materials prepared by inverse suspension polymerization. Eur. Polym. J.87, 124ā135. 10.1016/j.eurpolymj.2016.12.022
74
MetwallyM. G.BenhawyA. H.KhalifaR. M.El NasharR. M.TrojanowiczM. (2021). Application of molecularly imprinted polymers in the analysis of waters and wastewaters. Molecules26 (21), 6515. 10.3390/molecules26216515
75
Meza LópezF. de L.KhanS.PicassoG.SotomayorM. D. P. T. (2021). A novel highly sensitive imprinted polymer-based optical sensor for the detection of Pb(II) in water samples. Environ. Nanotechnol. Monit. Manag.16, 100497. 10.1016/j.enmm.2021.100497
76
MohammedE.ElsheikhM. M.El-ZomrawyA. A.AhmedF. A. (2023). Novel technique in production of Pb (II)- imprinted polymers. Al-Azhar Bull. Sci.34 (1). 10.58675/2636-3305.1633
77
MukendiM. D.SalamiO. S.MketoN. (2025). An In-Depth review of molecularly imprinted electrochemical sensors as an innovative analytical tool in water quality monitoring: architecture, principles, fabrication, and applications. Micromachines16 (3), 251. 10.3390/mi16030251
78
MuratA.WangL.AblizS.YimitA. (2022). Preparation, characterization of Cd(II) ion-imprinted microsphere and its selectivity for template ion. Coatings12 (8), 1038. 10.3390/coatings12081038
79
OlssonG. D.NiedergallK.BachM.KarlssonB. C. G.TovarG.NichollsI. A. (2015). Simulation of imprinted emulsion prepolymerization mixtures. Polym. J.47 (12), 827ā830. 10.1038/pj.2015.63
80
OseyemiA. E.RezaiP. (2025a). Low-Cost Lead-Ion Imprinted Polymer Membrane Microfluidic Sensor for Selective Trace Lead Monitoring in Water, 475ā478. 10.1109/transducers61432.2025.11110442
81
OseyemiA. E.RezaiP. (2025b). Microfluidic electrochemical sensor with lead ion-imprinted polymer membrane for selective trace lead detection in water. J. Water Process Eng.77, 108574. 10.1016/j.jwpe.2025.108574
82
PichonV.DelaunayN.CombĆØsA. (2020). Sample preparation using molecularly imprinted polymers. Anal. Chem.92 (1), 16ā33. 10.1021/acs.analchem.9b04816
83
PiletskyS. A.TurnerA. P. F. (2002). Electrochemical sensors based on molecularly imprinted polymers. Electroanalysis14 (5), 317ā323. 10.1002/1521-4109(200203)14:5<317::AID-ELAN317>3.0.CO;2-5
84
PiwowarskaD.KiedrzyÅskaE.JaszczyszynK. (2024). A global perspective on the nature and fate of heavy metals polluting water ecosystems, and their impact and remediation. Crit. Rev. Environ. Sci. Technol.54 (19), 1436ā1458. 10.1080/10643389.2024.2317112
85
PlanetaK.Kubala-KukusA.DrozdzA.MatusiakK.SetkowiczZ.ChwiejJ. (2021). The assessment of the usability of selected instrumental techniques for the elemental analysis of biomedical samples. Sci. Rep.11 (1), 3704. 10.1038/s41598-021-82179-3
86
ProveteC. S.DalfiorB. M.MantovaneliR.CarneiroM. T. W. D.BrandĆ£oG. P. (2024). Comparison of the performance of ICP-MS, CV-ICP-OES, and TDA AAS in determining mercury in marine sediment samples. ACS Omega9 (50), 49229ā49238. 10.1021/acsomega.4c06144
87
PrueittR. L.LiW.ChangY. C.BoffettaP.GoodmanJ. E. (2020). Systematic review of the potential respiratory carcinogenicity of metallic nickel in humans. Crit. Rev. Toxicol.50 (7), 605ā639. 10.1080/10408444.2020.1803792
88
QiD.ZhangH.ZhouZ.RenZ. (2023). Cadmium ion-imprinted polymers for adsorption and detection of cadmium ions. J. Environ. Chem. Eng.11 (5), 110804. 10.1016/j.jece.2023.110804
89
QiuS.ChangB.ChaiL.NieW.ZuL.LiuY.et al (2026). A U-shaped microfiber ring laser sensor for ultrasensitive detection of Ni2+ ions. Talanta297, 128547. 10.1016/j.talanta.2025.128547
90
RadfarR.AkinE.SehitE.Moldovean-CioroianuN. S.WolffN.MarquantR.et al (2024). Synthesis and characterization of coreāshell magnetic molecularly imprinted polymer nanocomposites for the detection of interleukin-6. Anal. Bioanal. Chem.416 (28), 6237ā6257. 10.1007/s00216-024-05536-x
91
Ralph PearsonB. G. (1963). Physical and inorganic chemistry hard and soft acids and bases. In J. Am. Chem. Soc. (Vol. 85, Number 22, pp. 3533ā3539). 10.1021/ja00905a001
92
RamanaviÄiusS.MorkvÄnaitÄ-VilkonÄienÄI.SamukaitÄ-BubnienÄU.RatautaitÄV.PlikusienÄI.ViterR.et al (2022). Electrochemically deposited molecularly imprinted polymerābased sensors. In Sensors (Vol. 22, 1282, 3). 10.3390/s22031282
93
RaoT. P.KalaR.DanielS. (2006). Metal ion-imprinted polymers-novel materials for selective recognition of inorganics. Anal. Chim. Acta578 (2), 105ā116. 10.1016/j.aca.2006.06.065
94
RaubA. A. M.BahruR.NashruddinS. N. A. M.YunasJ. (2024). A review on vertical aligned zinc oxide nanorods: synthesis methods, properties, and applications. J. Nanoparticle Res.26 (8), 186. 10.1007/s11051-024-06098-w
95
RaufM. F.LinZ.RaufM. K.LinJ. M. (2025). Innovative microfluidic technologies for rapid heavy metal ion detection. Chemosensors13 (4), 149. 10.3390/chemosensors13040149
96
RebeloP.Costa-RamaE.SeguroI.PachecoJ. G.NouwsH. P. A.CordeiroM. N. D. S.et al (2021). Molecularly imprinted polymer-based electrochemical sensors for environmental analysis. Biosens. Bioelectron.172, 112719. 10.1016/j.bios.2020.112719
97
RebeloP.SeguroI.NouwsH. P. A.Delerue-MatosC.PachecoJ. G. (2023). Molecularly imprinted plasmonic sensors for the determination of environmental water contaminants: a review. Chemosensors11 (6), 318. 10.3390/chemosensors11060318
98
Rebolledo-PeralesL. E.IbarraI.Franco GuzmĆ”nM.IslasG.Ćlvarez RomeroG. A. (2022). A novel ion-imprinted polymer based on pyrrole as functional monomer for the voltammetric determination of Hg(II) in water samples. Electrochimica Acta434, 141258. 10.1016/j.electacta.2022.141258
99
RenƩW.LenobleV.ChioukhM.BrangerC. (2020). A turn-on fluorescent ion-imprinted polymer for selective and reliable optosensing of lead in real water samples. Sensors Actuators, B Chem.319, 128252. 10.1016/j.snb.2020.128252
100
Rowley-NealeS. J.RandviirE. P.Abo DenaA. S.BanksC. E. (2018). An overview of recent applications of reduced graphene oxide as a basis of electroanalytical sensing platforms. Appl. Mater. Today10, 218ā226. 10.1016/j.apmt.2017.11.010
101
RoyB.BhuniaB.BandyopadhyayT. K.KhanS. A.NandiN. B.NathP. C. (2024). āWater pollution by heavy metals and their impact on human health,ā in Handbook of Water Pollution (Hoboken, NJ: John Wiley & Sons, Inc.), 332ā352. 10.1002/9781119904991.ch10
102
SadiqN.ShafiqueM.AkbarM.ShakoorM.MujahidA.HussainT.et al (2023). An ion-imprinted polymer-receptor-based electrochemical sensor for the sensitive and selective detection of cadmium. ChemistrySelect8 (10), e202204824. 10.1002/slct.202204824
103
SahaN.RahmanM. S.AhmedM. B.ZhouJ. L.NgoH. H.GuoW. (2017). Industrial metal pollution in water and probabilistic assessment of human health risk. J. Environ. Manag.185, 70ā78. 10.1016/j.jenvman.2016.10.023
104
SalaA.BrissetH.MargaillanA.MullotJ. U.BrangerC. (2022). Electrochemical sensors modified with ion-imprinted polymers for metal ion detection. TrAC - Trends Anal. Chem.148, 116536. 10.1016/j.trac.2022.116536
105
SebastianM.MathewB. (2018). Ion imprinting approach for the fabrication of an electrochemical sensor and sorbent for lead ions in real samples using modified multiwalled carbon nanotubes. J. Mater. Sci.53 (5), 3557ā3572. 10.1007/s10853-017-1787-x
106
ShamsipurM.SamandariL.Besharati-SeidaniA.PashabadiA. (2018). Synthesis, characterization and using a new terpyridine moiety-based ion-imprinted polymer nanoparticle: sub-nanomolar detection of Pb(II) in biological and water samples. Chem. Pap.72 (11), 2707ā2717. 10.1007/s11696-018-0523-6
107
ShenT.YangT.FengY.LiuX.LiuC.YuanW.et al (2024). Fiber optic cadmium ion sensors based on functionalization of a magnetic ion-imprinted polymer. Analyst149 (8), 2236ā2243. 10.1039/d3an02067c
108
StortiniA. M.BaldoM. A.MoroG.PoloF.MorettoL. M. (2020). Bio-and biomimetic receptors for electrochemical sensing of heavy metal ions. In Sensors Switz.201ā29. 10.3390/s20236800
109
SulthanaS. F.IqbalU. M.SuseelaS. B.AnbazhaganR.ChinthaginjalaR.ChitathuruD.et al (2024). Electrochemical sensors for heavy metal ion detection in aqueous medium: a systematic review. ACS Omega9 (24), 25493ā25512. 10.1021/acsomega.4c00933
110
TarleyC. R. T.BasagliaA. M.SegatelliM. G.PreteM. C.SuquilaF. A. C.de OliveiraL. L. G. (2017). Preparation and application of nanocomposite based on imprinted poly(methacrylic acid)-PAN/MWCNT as a new electrochemical selective sensing platform of Pb2 + in water samples. J. Electroanal. Chem.801, 114ā121. 10.1016/j.jelechem.2017.07.033
111
TchekwagepP. M. S.CrapnellR. D.BanksC. E.BetlemK.RinnerU.CanfarottaF.et al (2022). A critical review on the use of molecular imprinting for trace heavy metal and micropollutant detection. Chemosensors10 (8), 296. 10.3390/chemosensors10080296
112
TchounwouP. B.YedjouC. G.PatlollaA. K.SuttonD. J. (2012). Heavy metal toxicity and the environment. EXS101, 133ā164. 10.1007/978-3-7643-8340-4_6
113
TopcuC.LacinG.YilmazV.ColdurF.CaglarB.CubukO.et al (2018). Electrochemical determination of Copper(II) in water samples using a novel ion-selective electrode based on a graphite oxideāimprinted polymer composite. Anal. Lett.51 (12), 1890ā1910. 10.1080/00032719.2017.1395035
114
VelempiniT.PillayK.MbiandaX. Y.ArotibaO. A. (2018). Application of a polypyrrole/carboxy methyl cellulose ion imprinted polymer in the electrochemical detection of mercury in water. Electroanalysis30 (11), 2612ā2619. 10.1002/elan.201800445
115
WangJ.HuJ.HuS.GaoG.SongY. (2020). A novel electrochemical sensor based on electropolymerized ion imprinted popd/ergo composite for trace cd(Ii) determination in water. Sensors Switz.20 (4). 10.3390/s20041004
116
WangM.ChenZ.SongW.HongD.HuangL.LiY. (2021a). A review on cadmium exposure in the population and intervention strategies against cadmium toxicity. Bull. Environ. Contam. Toxicol.106 (1), 65ā74. 10.1007/s00128-020-03088-1
117
WangM.SongZ.JiangY.ZhangX.WangL.ZhaoH.et al (2021b). A three-dimensional pinwheel-shaped paper-based microfluidic analytical device for fluorescence detection of multiple heavy metals in coastal waters by rational device design. 10.1007/s00216-021-03269-9/Published
118
WangL.HuJ.WeiW.XiaoS.WangJ.SongY.et al (2023). An electrochemical sensor based on three-dimensional porous reduced graphene and ion imprinted polymer for trace cadmium determination in water. Sensors23 (23), 9561. 10.3390/s23239561
119
WeiP.ZhuZ.SongR.LiZ.ChenC. (2019). An ion-imprinted sensor based on chitosan-graphene oxide composite polymer modified glassy carbon electrode for environmental sensing application. Electrochimica Acta317, 93ā101. 10.1016/j.electacta.2019.05.136
120
WeiP.LiZ.ZhaoX.SongR.ZhuZ. (2020). Fe3O4/SiO2/CS surface ion-imprinted polymer modified glassy carbon electrode for highly sensitivity and selectivity detection of toxic metal ions. J. Taiwan Inst. Chem. Eng.113, 107ā113. 10.1016/j.jtice.2020.08.035
121
WolskaJ.Jalilnejad FaliziN. (2021). Membrane emulsification process as a method for obtaining molecularly imprinted polymers. Polymers13 (16), 2830. 10.3390/polym13162830
122
WuS.DaiX.ChengT.LiS. (2018). Highly sensitive and selective ion-imprinted polymers based on one-step electrodeposition of chitosan-graphene nanocomposites for the determination of Cr(VI). Carbohydr. Polym.195, 199ā206. 10.1016/j.carbpol.2018.04.077
123
WuS.LiK.DaiX.ZhangZ.DingF.LiS. (2020a). An ultrasensitive electrochemical platform based on imprinted chitosan/gold nanoparticles/graphene nanocomposite for sensing cadmium (II) ions. Microchem. J.155, 104710. 10.1016/j.microc.2020.104710
124
WuS.LiK.ZhangZ.ChenL. (2020b). Synthesis of imprinted chitosan/auNPs/Graphene-Coated MWCNTs/Nafion film for detection of lead ions. New J. Chem.44 (33), 14129ā14135. 10.1039/d0nj02522d
125
YangH. S.LafranceD. R.HaoY. (2021). Elemental testing using inductively coupled plasma mass spectrometry in clinical laboratories. Am. J. Clin. Pathology156 (2), 167ā175. 10.1093/ajcp/aqab013
126
YangH.YinF.MoY.HuoK.ZhangK.CaoH.et al (2023). An ion imprinted electrochemical sensor based on flower-like gold nanoparticles for the detection of trace arsenic(III) ions in water and food samples. Electroanalysis35 (8), e202200513. 10.1002/elan.202200513
127
YeL.MosbachK. (2008). Molecular imprinting: synthetic materials as substitutes for biological antibodies and receptors. Chem. Mater.20 (3), 859ā868. 10.1021/cm703190w
128
YeT.WuX.SuC.HuangM.BaiL.XueM.et al (2025). Polydopamine-coated aptamer-modified gold nanoparticles for enhanced Pb2+ sensing via molecular imprinting. Microchem. J.216, 114607. 10.1016/j.microc.2025.114607
129
YuL.SunL.ZhangQ.ZhouY.ZhangJ.YangB.et al (2022). Nanomaterials-based ion-imprinted electrochemical sensors for heavy metal ions detection: a review. Biosensors12 (12), 1096. 10.3390/bios12121096
130
ZarejousheghaniM.RahimiP.BorsdorfH.ZimmermannS.JosephY. (2021). Molecularly imprinted polymer-based sensors for priority pollutants. Sensors21 (7), 2406. 10.3390/s21072406
131
ZhangM. Y.HuangR. F.MaX. G.GuoL. H.WangY.FanY. M. (2019). Selective fluorescence sensor based on ion-imprinted polymer-modified quantum dots for trace detection of Cr(VI) in aqueous solution. Anal. Bioanal. Chem.411 (27), 7165ā7175. 10.1007/s00216-019-02100-w
132
ZhangR.GaoR.GouQ.LaiJ.LiX. (2022). Precipitation polymerization: a powerful tool for preparation of uniform polymer particles. Polymers14 (9), 1851. 10.3390/polym14091851
133
ZhangS.HuZ.LüS.BiX.LeiY. (2026). An MFC-IIP functionalized SNMNS optical fiber sensor for Cd2+ detection. Opt. Fiber Technol.98, 104561. 10.1016/j.yofte.2026.104561
134
ZhengX.KhaoulaniS.KtariN.LoM.KhalilA. M.ZerroukiC.et al (2021). Towards clean and safe water: a review on the emerging role of imprinted polymer based electrochemical sensors. Sensors21 (13), 4300. 10.3390/s21134300
135
ZhianiR.Ghanei-MotlagM.RazavipanahI. (2016). Selective voltammetric sensor for nanomolar detection of silver ions using carbon paste electrode modified with novel nanosized Ag(I)-imprinted polymer. J. Mol. Liq.219, 554ā560. 10.1016/j.molliq.2016.03.052
136
ZhouJ.LiB.QiA.ShiY.QiJ.XuH.et al (2020). ZnSe quantum dot based ion imprinting technology for fluorescence detecting cadmium and lead ions on a three-dimensional rotary paper-based microfluidic chip. Sensors Actuators, B Chem.305, 127462. 10.1016/j.snb.2019.127462
Summary
Keywords
electrochemical sensors, ion-imprinted polymers, molecularly imprinted polymers, toxic metal-ion detection, water quality monitoring
Citation
Yammouri G and Slaughter G (2026) Ion-imprinted polymer-based sensors for toxic metal-ion detection in water: coordination chemistry, transduction strategies, and environmental applications. Front. Chem. 14:1830143. doi: 10.3389/fchem.2026.1830143
Received
13 March 2026
Revised
21 June 2026
Accepted
24 June 2026
Published
27 July 2026
Volume
14 - 2026
Edited by
Jian Lu, Hainan University, China
Reviewed by
Li Wang, Anyang Institute of Technology, China
Nauman Sadiq, Quaid-i-Azam University, Pakistan
Updates
Copyright
Ā© 2026 Yammouri and Slaughter.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Gymama Slaughter, gslaught@odu.edu
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.