<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1404777</article-id>
<article-id pub-id-type="doi">10.3389/fenrg.2024.1404777</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Multi-dimensional potential assessment of grid-connected mega-scale floating PV power plants across heterogeneous climatic zones</article-title>
<alt-title alt-title-type="left-running-head">Mumtaz et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fenrg.2024.1404777">10.3389/fenrg.2024.1404777</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Mumtaz</surname>
<given-names>Amna</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2709809/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Abbas Kazmi</surname>
<given-names>Syed Ali</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2678468/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Altamimi</surname>
<given-names>Abdullah</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2600445/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Khan</surname>
<given-names>Zafar A.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Alyami</surname>
<given-names>Saeed</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>U.S.-Pakistan Center for Advanced Studies in Energy (USPCAS-E)</institution>, <institution>National University of Sciences and Technology (NUST)</institution>, <addr-line>Islamabad</addr-line>, <country>Pakistan</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Department of Electrical Engineering</institution>, <institution>College of Engineering</institution>, <institution>Majmaah University</institution>, <addr-line>Al-Majmaah</addr-line>, <country>Saudi Arabia</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Engineering and Applied Science Research Center</institution>, <institution>Majmaah University</institution>, <addr-line>Riyadh</addr-line>, <country>Saudi Arabia</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Department of Electrical Engineering</institution>, <institution>Mirpur University of Science and Technology</institution>, <addr-line>Mirpur</addr-line>, <country>Pakistan</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1789076/overview">Flah Aymen</ext-link>, &#xc9;cole Nationale d&#x27;Ing&#xe9;nieurs de Gab&#xe8;s, Tunisia</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2599618/overview">Ishak Ertugrul</ext-link>, Mus Alparslan University, T&#xfc;rkiye</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2597910/overview">Haroon Farooq</ext-link>, University of Engineering and Technology, Pakistan</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Saeed Alyami, <email>s.alyami@mu.edu.sa</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>22</day>
<month>05</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>12</volume>
<elocation-id>1404777</elocation-id>
<history>
<date date-type="received">
<day>21</day>
<month>03</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>22</day>
<month>04</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2024 Mumtaz, Abbas Kazmi, Altamimi, Khan and Alyami.</copyright-statement>
<copyright-year>2024</copyright-year>
<copyright-holder>Mumtaz, Abbas Kazmi, Altamimi, Khan and Alyami</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Floating Photovoltaic (FPV) systems are gradually becoming more desirable due to a multitude of reasons, encompassing proximity to urban water reservoirs (facilitating city access) and their technical advantages. Climate change potentially presents risks of drought and FPV can potentially benefit by providing clean energy as well as saving water from evaporation. However, detailed studies are required to comprehensively evaluate the potential of FPV considering not only the technical parameters but evaluating the climatic effects as well. This paper presents an integrated multi-dimensional framework for the analysis of 2.5&#xa0;MW grid-connected FPV systems over different climatic zones. In the first layer, a techno-economic and performance evaluation is carried out by fine-tuning different inputs of systems to make it ideal for proposed analyses under actual FPV conditions. Similarly, in the second layer environmental along with forest absorbing carbon analyses are performed. While socio analysis observed in the third fold is based on various SDGs and their indicators. Results reveal that the Dam with cold in winter and hot in summer climate conditions observed a most feasible site with a Levelized cost of energy (LCOE) of $0.047/kWh and a Net present value (NPV) of million $1.7705, respectively. In contrast, a Dam with mild cold climate conditions proves the least feasible site with LCOE of $0.057/kWh and NPV of million $1.0256, respectively. Similarly, the former Dam saved 20.50% higher CO<sub>2</sub> emissions as compared to the latter, as well as required hectares of forest absorbing carbon. A comparative analysis observes a capacity factor of 22% and a performance ratio (PR) of 5%&#x2013;10% higher as compared to solar photovoltaic (SPV) for dams with extreme weather.</p>
</abstract>
<kwd-group>
<kwd>floating photovoltaics</kwd>
<kwd>techno-economic analysis</kwd>
<kwd>environmental analysis</kwd>
<kwd>social analysis</kwd>
<kwd>renewable energy</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Process and Energy Systems Engineering</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Human social activities and lifestyles, as well as aquatic habitats, are influenced by fossil fuels. Carbon and hydrogen are the primary components of fossil fuels, but they also contain other substances e.g., lead, sulfur, and alcohol). Fossil fuel combustion results in the production of a variety of gases (COx, SOx, NOx, CH) ash and soot, tar droplets, and other organic compounds into the atmosphere, all of which contribute to air pollution. The health of people, animals, crops, and buildings is harmed by air pollution (<xref ref-type="bibr" rid="B9">Barbir et al., 1990</xref>). According to a statistical review of World Energy (2020), almost 84.3% of global energy comes from fossil fuels containing 33.1% of energy from oil resources, which always remained the main driver behind increasing oil prices in the international market and renewable has a share of only 11.4% of overall energy consumption (<xref ref-type="bibr" rid="B56">Statistical Review, 2020</xref>).</p>
<p>From the perspective of Asian countries, this energy mix situation is even more alarming as compared to other developed nations. For some countries, the domestic sector has the highest energy consumption share of 48%, while the industrial sector contributes 27% of the overall energy consumption (<xref ref-type="bibr" rid="B46">Raza et al., 2022</xref>). For some countries, the energy supply is mostly dependent on fossil fuels, with more than 63% thermal energy. Renewable energy (RE) like solar and wind often accounts for very little up to 3% of total electricity generation (<xref ref-type="bibr" rid="B46">Raza et al., 2022</xref>).</p>
<p>Renewable energy sources are the best option for addressing these challenges because of their long-term sustainability and environmentally friendly options (<xref ref-type="bibr" rid="B23">Goswami et al., 2019</xref>). Because of the threat posed by GHG emissions from fossil fuels and associated power generation, the usage of environmentally friendly renewable energy, notably SPV has gained enormous popularity as its demand has steadily increased by 20%&#x2013;25% per year across the globe over the first 2 decades of the twenty-first century. The rate of expansion of RE capacity has been fast-growing, yearly renewable capacity additions reached 45% to about 280&#xa0;GW in 2020, the biggest annual increase since 1999. Its appeal is based mostly on semiconductor technology, environmental benefits, policy-intensive nature, and ease of installation. Because they never run out of resources, photovoltaic (PV) and wind energy are the most widely adopted renewable energy sources across the globe. Most Asian countries have a good potential for solar or wind generation or hybrid. Most of the Asian countries existing energy mix is heavily reliant on fossil fuels (<xref ref-type="bibr" rid="B43">Ministry of Energy Petroleum Division, 2018</xref>).</p>
<p>The effective use of renewable energy potential is necessary to assure energy security and reduce climate change challenges. Further observations show that ground-mounted PV power plants in modern towns take up a lot of territory. As a result of this factor, land prices have risen, increasing the Levelized power tariff. The earth&#x2019;s total surface area is made up of 71% of water and 29% land. Land acquisition is another issue to address as the population grows, so the best solution is to put the water&#x2019;s idle surface to good use. Where, at the one hand, solar energy is gaining popularity due to its limitless energy supply. At the same time, on the other hand, the climatic conditions, design parameters, and operation parameters affect the performance of PV, due to which a 0.5% reduction in PV efficiency is observed by a 1&#xb0;C increase in temperature. PV efficiency gets decreased, as the module temperature increases due to a higher thermal effect of solar irradiance. Two major issues associated with land-based PV (LPV) i.e., land acquisition and high temperature have been solved by an emerging PV system concept called FPV. A comparison of LPV and FPV is given in <xref ref-type="table" rid="T1">Table 1</xref>.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Comparison between LPV and FPV (<xref ref-type="bibr" rid="B62">Where Sun Meets Water, 2019</xref>; <xref ref-type="bibr" rid="B45">Pimentel Da Silva and Branco, 2018</xref>).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="left">PV technology</th>
<th rowspan="2" align="left">Land-based PV (LPV)</th>
<th rowspan="2" align="left">Floating PV (FPV)</th>
<th colspan="2" align="left">Advantages</th>
</tr>
<tr>
<th align="right">LPV</th>
<th align="right">FPV</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="5" align="left">Surface (Water/Land)</td>
<td align="left">Required</td>
<td align="left">Land not required</td>
<td rowspan="5" align="left">&#x2717;</td>
<td rowspan="5" align="left">&#x2713;</td>
</tr>
<tr>
<td align="left">&#x2022; Require land for installation</td>
<td align="left">&#x2022; Water surface for installation</td>
</tr>
<tr>
<td align="left">&#x2022; Require expensive infrastructure</td>
<td align="left">&#x2022; Integrate with hydropower</td>
</tr>
<tr>
<td align="left">&#x2022; The permitting process is complicated</td>
<td rowspan="2" align="left">&#x2022; The permitting process is feasible</td>
</tr>
<tr>
<td align="left">&#x2022; Load lefts may be far away</td>
</tr>
<tr>
<td rowspan="3" align="left">Performance ratio</td>
<td align="left">Low as compared to FPV</td>
<td align="left">High as compared to LPV</td>
<td rowspan="3" align="left">&#x2717;</td>
<td rowspan="3" align="left">&#x2713;</td>
</tr>
<tr>
<td rowspan="2" align="left">&#x2022; Ranging from 75% to 80%</td>
<td align="left">&#x2022; Ranging from 80% to 89%</td>
</tr>
<tr>
<td align="left">&#x2022; 5%&#x2013;10% higher than LPV</td>
</tr>
<tr>
<td rowspan="2" align="left">Cost</td>
<td align="left">&#x2022; High initial cost</td>
<td rowspan="2" align="left">&#x2022; The cost is 18% higher than the land-based PV</td>
<td rowspan="2" align="left">&#x2713;</td>
<td rowspan="2" align="left">&#x2717;</td>
</tr>
<tr>
<td align="left">&#x2022; Procedures are established for financing and investment sector</td>
</tr>
<tr>
<td align="left">Project life</td>
<td align="left">&#x2022; Project major components have been durable for more than 20 years</td>
<td align="left">&#x2022; Floats of FPVs have a 5&#x2013;10-year warranty</td>
<td align="left">&#x2713;</td>
<td align="left">&#x2717;</td>
</tr>
<tr>
<td rowspan="2" align="left">Operation and maintenance</td>
<td align="left">&#x2022; Easy cleaning</td>
<td rowspan="2" align="left">&#x2022; Boats and divers are required for maintenance</td>
<td rowspan="2" align="left">&#x2713;</td>
<td rowspan="2" align="left">&#x2717;</td>
</tr>
<tr>
<td align="left">&#x2022; Vegetation growths have more effect on it</td>
</tr>
<tr>
<td rowspan="5" align="left">Environmental effects</td>
<td align="left">&#x2022; Deforestation for site accessing and project implementation</td>
<td align="left">&#x2022; Reduction in Algae growth</td>
<td rowspan="5" align="left">&#x2717;</td>
<td rowspan="5" align="left">&#x2713;</td>
</tr>
<tr>
<td align="left">&#x2022; Soiling</td>
<td align="left">&#x2022; Reduce water evaporation</td>
</tr>
<tr>
<td rowspan="3" align="left">&#x2022; Erosion</td>
<td align="left">&#x2022; Improves water quality</td>
</tr>
<tr>
<td align="left">&#x2022; Environmental influence on the</td>
</tr>
<tr>
<td align="left">&#x2022; aquatic ecosystems</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>This concept works best in densely populated areas with uneven terrain. For hot and arid regions, FPV has a lot of potential since the operating temperature can be controlled and the PV performance can be optimized. FPV systems offer new ways to expand solar power generation capacity due to their high efficiency as compared to LPV. They can be integrated with hydroelectric power plants and have a considerable impact on supplying electric load in various spans of the year, particularly during the hot and dry seasons. A standalone system needs a large power storage infrastructure, which almost doubles the system&#x2019;s overall capital cost, and challenges the economic feasibility of the systems (<xref ref-type="bibr" rid="B57">Temiz and Dincer, 2021</xref>). Moreover, as the number of components increases, it suffers a significant power dissipation loss which poses a substantial challenge to system performance. As a result, grid-connected configurations are widely adopted for most practical scenarios.</p>
<p>In comparison to LPV systems, FPV provides technological, economic, social, and environmental advantages. Furthermore, due to fluctuating fuel prices on the worldwide market, electricity prices are always changing. Hydropower accounts for 26% of total output, and the dam&#x2019;s idle surfaces may be utilized to generate energy by dedicating water surfaces to FPV installations. An integrated infrastructure of floating systems and PV plants is referred to as an FPV plant. A crystalline and thin-film FPV offers financial benefits of more than $129 cents/L over diesel-fueled energy production sources (<xref ref-type="bibr" rid="B58">Trapani and Millar, 2016</xref>). The efficiency of the LPV system is around 15%, which may be enhanced further by using FPV to take advantage of the cooling effects of water. FPVs are also favored over LPVs because they have a recyclable platform. Additionally, they are recommended for generating energy in remote locations and places with land accessibility and water conservation issues, such as salt mines and oil refineries that are far from grid stations.</p>
<p>The development of FPV systems is in its early stages, emphasizing the need for comprehensive long-term performance and feasibility studies. Precise parameter estimation is crucial for gauging actual performance, carbon savings, and facilitating the deployment of FPV systems. Accurate modeling not only supports researchers, scientists, and engineers in making informed decisions but also contributes to the establishment of a sustainable ecosystem aligned with low-carbon power generation methods within the framework of Industry 4.0 (<xref ref-type="bibr" rid="B25">Goswami and Sadhu, 2022</xref>). Notably, FPV systems, operating on water with higher relative humidity and lower temperatures compared to LPV systems, exhibit superior energy output despite the observed impact on the performance ratio (PR). This underscores the potential of FPV systems to offer efficient and sustainable solutions in the evolving landscape of renewable energy (<xref ref-type="bibr" rid="B22">Goswami, 2023</xref>). FPVs are preferred over LPVs for several reasons, including FPVs avoid high dust accumulation because they are installed on the surface of the water, FPVs reduce evaporation in water reservoirs, decrease GHG emissions, Save high land purchase costs, utilize idle water surfaces, address the problem of increased electricity transportation costs, conquer high-temperature impacts on SPVs, reduce algae growth, satisfy energy demand, and overcome long and tedious installation times.</p>
</sec>
<sec id="s2">
<title>2 Potential overview of FPV plants across world</title>
<p>Several states in the United States have set a goal of producing 100% renewable energy-based green power by 2040, incorporating both centralized and decentralized generation. By 2040, several European and Asian countries have set a target of producing more than half of their total electricity from renewable sources (<xref ref-type="bibr" rid="B61">Uddin et al., 2022</xref>).</p>
<p>IRENA has identified FPV as a rising niche and an emerging technology. According to NREL, FPVs have a 7.6&#xa0;TW potential on hydropower reservoirs. In almost 40 countries, FPVs have been built on reservoirs, freshwater lakes, and dams. Since 2007, different FPV plants ranging in size from a few kW to a few megawatts have been developed and are now functional in many countries (<xref ref-type="bibr" rid="B59">Trapani and Red&#xf5;n Santaf&#xe9;, 2015</xref>). The first 20&#xa0;kW FPV system was installed in Japan in 2007, and Ciel &#x26; Terre was the first FPV installation French company has built several projects on both artificial and natural water bodies. According to a market perspective, the global market for FPV is growing rapidly, and it is predicted to reach $842 million by the end of 2023. According to the IEA, adding FPVs to the water bodies of hydropower stations may yield a potential power of roughly 10,600&#xa0;TWh per year, whereas total world energy consumption in 2018 was 22,300&#xa0;TWh.</p>
<p>Internal cell temperature has a significant impact on solar PV efficiency. The cooling effect of the water surface reduces the internal temperature which boosts the system&#x2019;s energy efficiency by 5%. Among renewable technologies, FPV technology is becoming more attractive for both research and commercial operations. It is expected to reach 4.13&#xa0;GW of installed capacity by 2024, with a compound annual growth rate of 30%. Although installing a floating structure, extra insulation, and equipment increases capital and operational costs by 25%, lower land prices may compensate for the higher expenditures (<xref ref-type="bibr" rid="B57">Temiz and Dincer, 2021</xref>). The primary issue with FPV is the initial investment, which is decreasing with time and will soon be competitive with LPV. The solar industry in Asia is booming, thanks to the fact that 78% of Asia&#x2019;s water bodies are appropriate for FPV installation. FPV is a cutting-edge technology that can solve the current energy deficit while also providing economic and environmental benefits by lowering <inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> emissions.</p>
<p>A test case in India is taken on the Mettur dam in Tamil Nadu to analyze the performance of FPVs. A land-scaped flat-mounted system was found to have a high-performance ratio (PR). A 1&#xa0;MW FPV system having a component configuration of four 250&#xa0;kW inverters, four blocks, and twenty strings was proposed by Indonesia in 2019. Three reservoirs were chosen for simulation and modeling reasons. Sungrow, a Chinese business, built a 600&#xa0;kW FPV plant in Hanoi, Vietnam. <xref ref-type="table" rid="T2">Table 2</xref> shows a potential summary of FPV from 2007 to 2017. Recently Portugal launched an auction of 26&#xa0;MW which is allocated to seven different dams, having diverse capacities, summarized in <xref ref-type="table" rid="T3">Table 3</xref>.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Potential summary of FPV from 2007-17.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">FPV installation</th>
<th align="left">Sites</th>
<th align="left">Country</th>
<th align="left">Capacity</th>
<th align="left">Year</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">First researched FPV</td>
<td align="left">Aichi Province</td>
<td align="left">Japan</td>
<td align="left">20&#xa0;kWp</td>
<td align="left">2007</td>
</tr>
<tr>
<td align="left">First non-researched FPV</td>
<td align="left">Far Niente Winery</td>
<td align="left">United States of America</td>
<td align="left">175&#xa0;kWp</td>
<td align="left">2008</td>
</tr>
<tr>
<td align="left">First FPV with tracking</td>
<td align="left">Petra Winery</td>
<td align="left">Italy</td>
<td align="left">200&#xa0;kWp</td>
<td align="left">2010</td>
</tr>
<tr>
<td align="left">First FPV with MW capacity</td>
<td align="left">Saitama Prefecture</td>
<td align="left">Japan</td>
<td align="left">1,180&#xa0;kWp</td>
<td align="left">2013</td>
</tr>
<tr>
<td align="left">First FPV with micro-inverters</td>
<td align="left">Fukuoka Prefecture</td>
<td align="left">Japan</td>
<td align="left">300&#xa0;kWp</td>
<td align="left">2016</td>
</tr>
<tr>
<td align="left">First FPV and hydro combination</td>
<td align="left">Alto Rabag&#x101;o Dam</td>
<td align="left">Portugal</td>
<td align="left">220&#xa0;kWp</td>
<td align="left">2017</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Portugal launched an auction and the capacity of the dams.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Dams</th>
<th align="center">Capacity (MW)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Alqueva</td>
<td align="center">50</td>
</tr>
<tr>
<td align="center">Castelo de Bode</td>
<td align="center">33</td>
</tr>
<tr>
<td align="center">Cabril</td>
<td align="center">33</td>
</tr>
<tr>
<td align="center">Alto Rabag&#xe3;o</td>
<td align="center">42</td>
</tr>
<tr>
<td align="center">Paradela</td>
<td align="center">13</td>
</tr>
<tr>
<td align="center">Salamonde</td>
<td align="center">8</td>
</tr>
<tr>
<td align="center">Tabua&#xe7;o</td>
<td align="center">17</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>A total of ten of the largest FPV farms are summarized in <xref ref-type="table" rid="T4">Table 4</xref>. There are various FPV solution providers for offshore, near-shore, and interior freshwater applications all around the world. FPV solutions for inland freshwater are provided by companies such as Ciel &#x26; Terre International, Kyoraku, LG CNS, LSIS, Scotra, SMCC, Sungrow, and Xiamen Mibet New Energy while floating technology solutions for offshore uses are provided by Ocean Sun and Swimsol.</p>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Ten largest scheduled FPV power plant projects.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Sr.</th>
<th align="left">Project name</th>
<th align="left">Country</th>
<th align="left">Capacity</th>
<th align="left">Location of site</th>
<th align="left">Op.yr</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">1</td>
<td align="left">Saemangeum floating solar energy</td>
<td align="left">South Korea</td>
<td align="left">2.1&#xa0;GW</td>
<td align="left">Coast Yellow Sea</td>
<td align="left">2023</td>
</tr>
<tr>
<td align="left">2</td>
<td align="left">Omkareshwar dam floating solar farm</td>
<td align="left">India</td>
<td align="left">600&#xa0;MW</td>
<td align="left">Dam in Madhya Pradesh</td>
<td align="left">2023</td>
</tr>
<tr>
<td align="left">3</td>
<td align="left">Hangzhou Fengling Electricity Science Technology solar farm</td>
<td align="left">China</td>
<td align="left">320&#xa0;MW</td>
<td align="left">Change and Zhouxiang reservoirs in Cixi</td>
<td align="left">2020</td>
</tr>
<tr>
<td align="left">4</td>
<td align="left">Three Gorges&#x2019; new energy floating solar farm</td>
<td align="left">China</td>
<td align="left">150&#xa0;MW</td>
<td align="left">Lake in Anhui Province</td>
<td align="left">2017</td>
</tr>
<tr>
<td align="left">5</td>
<td align="left">Cirata Reservoir floating photovoltaic power project</td>
<td align="left">Indonesia</td>
<td align="left">145&#xa0;MW</td>
<td align="left">Cirata Reservoir</td>
<td align="left">2022</td>
</tr>
<tr>
<td align="left">6</td>
<td align="left">NTPC Kayamkulam solar</td>
<td align="left">India</td>
<td align="left">105&#xa0;MW</td>
<td align="left">The reservoir of NTPC Kayamkulam in Alappuzha, Kerala</td>
<td align="left">2019</td>
</tr>
<tr>
<td align="left">7</td>
<td align="left">NTPC Ramagundam solar</td>
<td align="left">India</td>
<td align="left">100&#xa0;MW</td>
<td align="left">A reservoir of NTPC Ramagundam in Telangana</td>
<td align="left">2020</td>
</tr>
<tr>
<td align="left">8</td>
<td align="left">CECEP&#x2019;s floating solar project</td>
<td align="left">China</td>
<td align="left">70&#xa0;MW</td>
<td align="left">Anhui Province</td>
<td align="left">2019</td>
</tr>
<tr>
<td align="left">9</td>
<td align="left">Sembcorp Tuas FPV project</td>
<td align="left">Singapore</td>
<td align="left">60&#xa0;MW</td>
<td align="left">Tengeh Reservoir in Tuas</td>
<td align="left">2021</td>
</tr>
<tr>
<td align="left">10</td>
<td align="left">Hapcheon Dam FPV</td>
<td align="left">South Korea</td>
<td align="left">41&#xa0;MW</td>
<td align="left">Hapcheon Dam</td>
<td align="left">2020</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s3">
<title>3 Potential overview of FPV plants across research problem</title>
<p>As the world&#x2019;s population grows, land use competition for buildings, industry, power production, transportation, and ecosystem products and services intensify. FPV systems have shown promise as a technical solution for land acquisition, and several studies have been conducted, with these systems being examined from a variety of angles. A rigorous techno-economic and sustainability assessment of these solar technologies reveals a plethora of benefits, including cost-effective and environmentally friendly solutions. Due to its high initial investment and lack of appropriate water bodies, FPV technology currently faces several technical and practical challenges. Various studies have been performed to carry out these challenges across different regions with different sites&#x2019; specific natures. Pietro et al. (<xref ref-type="bibr" rid="B10">Campana et al., 2019</xref>) have proposed an approach to analyzing numerous scenarios for optimal integration of hybrid renewable energy systems into a typical shrimp farm by taking the case of Thailand with the aims of renewable energy exploitation and decarbonization of the shrimp farming sector. FPV plants and FPV tracking systems are being examined as solar energy solutions to supply the shrimp farm&#x2019;s power requirements. The authors investigated the integration impacts with the different optimal configurations of hybrid energy sources. Results summarized that the incorporation of FPV is a crucial approach for minimizing shrimp farming&#x2019;s ecological consequences.</p>
<p>In India, FPVs have a lot of potential, and their efficiency is thought to be higher than that of LPVs. FPVs can manage and minimize algae growth and water evaporation by 70% and require less maintenance. FPV is made up of three basic parts: a mooring system, a pontoon, and floats. By altering the tilt angle of the PV panels, the problem of water shading may be solved.</p>
<p>During rainy seasons, the mooring system should be strong enough to withstand the effects of flooding (<xref ref-type="bibr" rid="B3">Akole and Jadhav, 2018</xref>). Temperature and dust are two important effecting variables in SPV that can be addressed with the use of FPVs. The FPV system is considered an ideal solution for land-constrained sites, high population density, numerous water resources, and high evaporation rates. FPVs are cost-effective solutions due to lower cleaning costs and no need for land (<xref ref-type="bibr" rid="B65">Zahedi et al., 2021</xref>). Contraction, tracking, and cooling techniques for FPVs can help in increasing the efficiency of the overall PV system. Flat reflectors and positive trackers enhanced power generation considerably. A different indicator like the thermal coefficient plays a major role in predicting the efficiency of system. A negative thermal coefficient means that the efficiency of the commercial PV system is inversely proportional to cell temperature. For silicon crystalline PV technologies, it ranges from 0.4% to 0.45%/<sup>o</sup>C whereas for a-Si it is 0.2%/<sup>o</sup>C (<xref ref-type="bibr" rid="B11">Cazzaniga et al., 2018</xref>).</p>
<p>An FPV power plant might help the San Francisco River Integration Project (SFIP), which aims to supply water to 12 million people in the Brazilian semiarid. The SFIP needs a substantial quantity of energy in an area where power costs have climbed, and water usage has increased over the previous decade. The results established the techno-economic feasibility of this technology linked to the SFIP by simulating an FPV power plant using the System Advisor Model (SAM) employing approaches and parameters from existing FPV projects. The FPV&#x2019;s environmental implications and importance in the Brazilian Northeast&#x2019;s water-energy nexus are also examined by Luana Carolina Alves da Costa et al., (<xref ref-type="bibr" rid="B17">da Costa and da Silva, 2021</xref>). The FPV might reduce SFIP running costs, reduce environmental impacts, and increase water and energy management efficiency. Such elements are significant when looking at the water-energy interconnection in a location where there is strong competition for water and extended periods of drought.</p>
<p>Southern European countries have ideal climate conditions for boosting solar energy adoption. J. Baptista et al. (<xref ref-type="bibr" rid="B8">Baptista et al., 2021</xref>), looked at the possibility and grid integration for FPV systems in Portugal. The Gouves dam, which is part of the T&#xe2;mega hydropower complex under development in northern Portugal, was used to test the sizing and performance of a 1&#xa0;MW FPV power plant. A techno-economic feasibility analysis was also carried out, taking into account the current investment costs and energy tariffs in the liberalized Iberian market. This in-depth analysis uncovered crucial information regarding the present state of the art, the types of technologies that are accessible, their costs, and the payback period (PBP) for similar projects. In 2020 J. Haas (<xref ref-type="bibr" rid="B27">Haas et al., 2020</xref>) took to Rapel reservoir in central Chile to examine the impact of FPVs on water quality as well as on hydropower production. FPV reveals several advantages including water quality improvement by eliminating algae blooms and the area covered with FPVs has a direct impact on cost and ecological health. If 40%&#x2013;60% area will cover it can eliminate 100% of algae without severe financial hydropower loss. For more than 60% of the area covered, ecological heath will affect major economic hydropower loss because of no sunlight in the reservoir. Evaporation from open water reservoirs, such as dams, results in a significant loss of water resources. By merging FPVs with HEPP, water is conserved as well as power is generated for electrification purposes. For nearly 2&#xa0;decades, satellite photographs of Turkey&#x2019;s Demirk&#xf6;pr&#xfc; dam were used to locate the best location for FPV installation, where high power generation was recorded with minimal evaporation (<xref ref-type="bibr" rid="B5">Ates et al., 2020</xref>). China has a rich potential for FPV installation having almost 2,865 lakes with a surface area of 78,000 sq. km. The efficiency of FPVs over standard terrestrial PVs improves when the operating temperature drops due to the cooling effect (<xref ref-type="bibr" rid="B36">Liu et al., 2017</xref>). R. Cazzaniga et al. (<xref ref-type="bibr" rid="B11">Cazzaniga et al., 2018</xref>) investigated the performance of FPV plants and proposed various design options for increasing efficiency and cost-effectiveness. FPV systems, in particular, make use of added characteristics like cooling, tracking, and concentration. A floating structure on the water was used to demonstrate the possibility of constructing an integrated air storage system.</p>
<p>According to the findings of (<xref ref-type="bibr" rid="B23">Goswami et al., 2019</xref>), The production capacity of a 10&#xa0;MW FPV plant is 10.2% higher than an LPV system. The FPV plant saves $352,125 in land expenses and $47,600 in water cess. Furthermore, the FPV plant saves tons of coal and 340801.74 tons of <inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>. It helps to close down the energy demand-supply gap while also cutting electricity costs and protecting natural resources. A case study of a 1&#xa0;MW FPV plant at Ambazari Lake in Nagpur, Maharashtra, India is presented by Swati S. Gurfude et al. (<xref ref-type="bibr" rid="B26">Gurfude et al., 2020</xref>). The generating efficiency of an FPV plant will be 2.5%&#x2013;3% greater than that of a standard ground-mounted PV plant, and evaporation would save 191 million liters of water each year. The FPV plant will be able to close the gap between electrical energy demand and supply.</p>
<p>Integrating FPVs with HEPP by installing them at dam reservoirs to make use of the optimum energy combination is also a brilliant way to save money associated with transmission and distribution infrastructure. In Bangladesh, the technical feasibility and financial viability of a 50&#xa0;MW plant integrated with a hydroelectric dam were investigated. The plant may reduce <inline-formula id="inf3">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> emissions by 52.8 million tons by using an ecologically sustainable strategy. In comparison to terrestrial LPV plants, FPVs have several advantages, including fewer obstacles to block sunlight, reduced water evaporation, irrigation, and domestic sustainability, higher energy efficiency due to the cooling effect of water, and the ability to limit algae growth by restricting sunlight penetration (<xref ref-type="bibr" rid="B40">Miah et al., 2021</xref>).</p>
<p>According to literature surveys, relatively few studies on the techno-economic, environmental, and social (TEES) assessment of grid-connected FPV systems for various sectors have been published. Most of the studies are related to techno-economic analysis of standalone FPV system. For example, with the goal of evaluating the feasibility of implementing a FPV system on an urban lake site, the authors in reference (<xref ref-type="bibr" rid="B28">Hafeez et al., 2022</xref>) conducted a techno-economic assessment. This assessment aimed to estimate the potential deployment of the FPV system, assess its scope, and compare it with a ground-based photovoltaic system with similar specifications. The study focused on an urban lake within institutional premises. In reference (<xref ref-type="bibr" rid="B42">Micheli et al., 2022</xref>), the authors evaluated the potential energy yield and cost-effectiveness of FPV systems over appropriate water bodies in Europe. The comparison was made against land-based photovoltaic systems with optimal tilt angles. In reference (<xref ref-type="bibr" rid="B33">Kowsar et al., 2023</xref>), researchers conducted a comprehensive examination of the techno-economic and environmental aspects of a 50&#xa0;MW FPV power plant situated in a marsh area within an extremely densely populated country. Utilizing PVsyst simulation tools, the study revealed that the levelized cost of energy (LCOE) for the 50&#xa0;MW FSPV plant is US$ 0.051/kWh, significantly lower than the US$ 0.087/kWh observed for fossil fuel-based power plants in the studied nation. Additionally, the proposed FSPV system contributes to reductions in CO<sub>2</sub> emissions, water evaporation, and supports biodiversity conservation in marshlands. Likewise, employing a GIS-MCDA model, an evaporation model, and incorporating a cost-benefit analysis, the study outlined in (<xref ref-type="bibr" rid="B6">Bai et al., 2024</xref>) assessed the prospective growth of FPV systems in China. The research delves into the energy-land-water co-benefits associated with FPV. Additionally, the analysis extends to unveiling the existing land limitations for the deployment of solar photovoltaics in China, with an evaluation of the potential for traditional terrestrial solar photovoltaic systems. To the best of the authors&#x2019; knowledge, no study in the literature reported an integrated analysis of techno-economic, environmental, and social (TEES) feasibility along with performance evaluation of mega-scale FPV systems, especially from the metrological and geographical point of view of south Asian country. It is worth mentioning here that FPV installation and performance work differently compared to LPV. Various parameters like U-value and Albedo differ in FPV as compared to LPV. Most of the previous studies performed an analysis based on the same or default U-value and Albedo for FPV as these are kept in LPV. However, in actual conditions, for correct analysis and performance evaluation of FPV, the U-value and Albedo should be customized differently as compared to LPV. For that reason, in this study, these parameters are customized in PVsyst during simulation to reach the true cost of energy and other technical and performance parameters. Moreover, no study has been reported in the literature concerning forest absorbing carbon emissions analysis along with environmental analysis. As well as previous studies have focused on limited decision parameters, mostly NPV and LCOE to reach the optimal decision regarding the techno-economic feasibility of FPV systems. In contrast, this study has focused on various techno-economic, performance, and environmental decision parameters at the same time. A comparative analysis of previously reported studies and the contribution of the proposed study is summarized in <xref ref-type="table" rid="T5">Table 5</xref>. Likewise, similar studies have conducted in (<xref ref-type="bibr" rid="B38">Ma et al., 2023</xref>) where concentrated solar power, offers reliability and dispatch by complementing extensive thermal energy storage. The concerned stability regions can-be tackled accurately for grid-connected systems, by employing a nonlinear multi-parameter analysis method based on tracking limit cycle amplitudes (<xref ref-type="bibr" rid="B64">Yao et al., 2024</xref>) and can mitigate consumption conflicts with the potential to meet total electricity demand (<xref ref-type="bibr" rid="B63">Yang et al., 2024</xref>).</p>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Summary of major carried literature review and contribution of the proposed study.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Ref.</th>
<th align="center">CNT</th>
<th align="center">Power</th>
<th align="center">Site type</th>
<th align="center">Method</th>
<th colspan="4" align="center">Analysis</th>
<th align="center">CFA</th>
<th align="center">OGI</th>
<th colspan="10" align="center">Decision parameters</th>
</tr>
<tr>
<th align="left"/>
<th align="left"/>
<th align="left"/>
<th align="left"/>
<th align="left"/>
<th align="center">T</th>
<th align="center">E</th>
<th align="center">E&#x2a;</th>
<th align="center">S</th>
<th align="left"/>
<th align="left"/>
<th align="center">ROI</th>
<th align="center">IRR</th>
<th align="center">LCOE</th>
<th align="center">NVP</th>
<th align="center">PBP</th>
<th align="center">CUF</th>
<th align="center">SP</th>
<th align="center">PR</th>
<th align="center">SDGs</th>
<th align="center">SEm</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">
<xref ref-type="bibr" rid="B7">Bakar and Nandong (2019)</xref>
</td>
<td align="center">MAL</td>
<td align="center">1&#xa0;GW</td>
<td align="center">Lake</td>
<td align="center">HBOA</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">No</td>
<td align="center">No</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B39">Martins (2019)</xref>
</td>
<td align="center">United States of America</td>
<td align="center">3&#xa0;MW</td>
<td align="center">WT</td>
<td align="center">MATLAB</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B49">Semeskandeh et al. (2022)</xref>
</td>
<td align="center">IRN</td>
<td align="center">5&#xa0;KW</td>
<td align="center">Caspian Sea</td>
<td align="center">MATLAB RETScreen</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B23">Goswami et al. (2019)</xref>
</td>
<td align="center">IND</td>
<td align="center">10&#xa0;MW</td>
<td align="center">Dam</td>
<td align="center">PVSyst (NVP)</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B40">Miah et al. (2021)</xref>
</td>
<td align="center">BNG</td>
<td align="center">50&#xa0;MW</td>
<td align="center">Dam</td>
<td align="center">MC</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B52">Snehith and Kulkarni (2021a),</xref> <xref ref-type="bibr" rid="B53">Snehith and Kulkarni (2021b)</xref>
</td>
<td align="center">IND</td>
<td align="center">10&#xa0;MW</td>
<td align="center">Dam</td>
<td align="center">MATLAB</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B31">Jiang et al. (2020)</xref>
</td>
<td align="center">CHN</td>
<td align="center">288.8&#xa0;MW</td>
<td align="center">DWP</td>
<td align="center">Open-source code OptiCE</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B18">Dizier (2018)</xref>
</td>
<td align="center">TWN</td>
<td align="center">1.132&#xa0;MWp</td>
<td align="center">RP</td>
<td align="center">MATLAB</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B57">Temiz and Dincer (2021)</xref>
</td>
<td align="center">CND</td>
<td align="center">2.2&#xa0;MWp</td>
<td align="center">Island</td>
<td align="center">PVsyst (NVP) HOMER</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
</tr>
<tr>
<td align="center">
<xref ref-type="bibr" rid="B61">Uddin et al. (2022)</xref>
</td>
<td align="center">BNG</td>
<td align="center">1.4&#xa0;MW</td>
<td align="center">Coastal Area</td>
<td align="center">MATLAB HOMER</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">No</td>
<td align="center">No</td>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="center">&#x2713;</td>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="left"/>
<td align="center">&#x2713;</td>
</tr>
<tr>
<td align="center">PS</td>
<td align="center">PAK</td>
<td align="center">2.5&#xa0;MW</td>
<td align="center">Dams and Barrage</td>
<td align="center">PVsyst (VP) RETScreen</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
<td align="center">&#x2713;</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>CNT: country, MAL: malaysia, IRN: iran, IND: india, BNG: bangladesh, CHN: china, TWN: taiwan, CND: canada, PAK: pakistan, HBOA: heuristic-based optimization approach, T: technical, Eco: Economical, Env: Environmental, S: social, CFA: Carbon-absorbing Forest Analysis, OGI: On-ground inputs, LCOE: levelized cost of energy, ROI: rate on investment, PBP: payback period, CUF: capacity utilization factor, SP: specific production, PR: performance ratio, SDGs: Sustainable Development Goals, SE<sub>m</sub>: Saved Emissions, NVP: No Varying Parameters for Floating PVs, VP: Varied Parameters for Floating PVs (mentioned in <xref ref-type="table" rid="T12">Table 12</xref>), WT: wastewater treatment facility, MC: manual calculations, DWP: deep water port, RP: Regulation Pond.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>The current study will examine the technical, economic, and socio-environmental benefits of a 2.5&#xa0;MW grid-connected FPV system in five climate zones and propose a strategy for installing an FPV system in the most favorable climate zone to tap new technology-based renewable potential and to improve the country&#x2019;s current energy mix. To the best of the authors&#x2019; knowledge, no study in the literature has provided a thorough feasibility analysis of significant water bodies. The majority of the research examined just one or two climatic scenarios to assess the viability of floating infrastructure. This study encompasses a variety of meteorological zones with an emphasis on the country&#x2019;s current climate conditions. Additionally, the majority of earlier studies did not use on-ground inputs, whereas proposed investigations concentrate on on-ground inputs to determine whether the proposed architecture is feasible. From an environmental analysis point of view, the literature has substantially focused on only emitted carbon emissions. No study regarding FPV focused on providing an alternate solution for the mitigation or absorption of these carbon emissions. The current aims are to conduct forests absorbing carbon emissions analysis along with carbon emission analysis to carry a policy solution to absorb the same carbon emissions. In a nutshell, the major contribution with respect to the reviewed literature is shown in <xref ref-type="table" rid="T5">Table 5</xref>.</p>
<p>This paper is organized as follows: <xref ref-type="sec" rid="s1">Section 1</xref> carried the introduction of current energy scenarios across the globe and more specifically in Asian countries. <xref ref-type="sec" rid="s2">Section 2</xref> carried the history behind applications of FPV and some major associated projects across the globe are summarized. In <xref ref-type="sec" rid="s3">Section 3</xref>, a literature work is summarized, and research gaps are identified. The methodology is summarized in <xref ref-type="sec" rid="s4">Section 4</xref>. In <xref ref-type="sec" rid="s5">Section 5</xref>, results and discussion are carried out briefly. In <xref ref-type="sec" rid="s6">Section 6</xref>, tracking FPV is discussed and in Section 7, the limitations of the FPV plant are discussed. Finally, the policy recommendations are carried out in Section 8 and the paper is concluded in Section 9.</p>
</sec>
<sec sec-type="methods" id="s4">
<title>4 Methodology</title>
<p>FPV plants are well-established technologies. FPV can be installed on various sites mainly categorized as man-made or artificial water bodies, industrial and agricultural water bodies, and offshore water bodies (<xref ref-type="bibr" rid="B62">Where Sun Meets Water, 2019</xref>). In this research, man-made or artificial water bodies are considered like dams and barrages to perform multidimensional analysis for finding out the most practical site for FPV installation. Furthermore, these sites are divided into subcategories explained in <xref ref-type="fig" rid="F1">Figure 1A</xref>.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>
<bold>(A)</bold> Potential sites for FPV power plant installation. <bold>(B)</bold> Geographical placements of the five climate zones.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g001.tif"/>
</fig>
<p>To examine the most essential impact characteristics, five representative sites including Zone A dam, Zone B dam, Zone C dam, Zone D dam, and Zone E dam were selected to represent the five climatic zones for the techno-economic-environmental and social analysis of a 2.5&#xa0;MW FPV. <xref ref-type="table" rid="T6">Table 6</xref> offers coordinate details for selected sites, and cities, whereas <xref ref-type="fig" rid="F1">Figure 1B</xref> depicts the geographical placements of the five climate zones. Solar PV systems with a 1&#xa0;MW capacity require around 20,000 square meters of land to install (<xref ref-type="bibr" rid="B62">Where Sun Meets Water, 2019</xref>). Approximately 50,000 square meters of land would be saved by installing a 2.5&#xa0;MW FPV system. In this study, the discount rate and inflation rate are taken as 9.75% and 8.5%, respectively.</p>
<table-wrap id="T6" position="float">
<label>TABLE 6</label>
<caption>
<p>Coordinate details of selected sites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">S. No</th>
<th align="left">Site</th>
<th align="left">City</th>
<th align="left">Latitude</th>
<th align="left">Longitude</th>
<th align="left">Altitude (m)</th>
<th align="left">Zone</th>
<th align="left">Climate</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">1</td>
<td align="left">Tarbela dam</td>
<td align="left">Haripur</td>
<td align="left">34.0922<sup>o</sup>N</td>
<td align="left">72.6852<sup>o</sup>E</td>
<td align="left">446</td>
<td align="left">Zone A</td>
<td align="left">Cold</td>
</tr>
<tr>
<td align="left">2</td>
<td align="left">Ghazi Barotha Dam</td>
<td align="left">Attock</td>
<td align="left">33.7935<sup>o</sup>N</td>
<td align="left">72.2637<sup>o</sup>E</td>
<td align="left">324</td>
<td align="left">Zone B</td>
<td align="left">Mild cold</td>
</tr>
<tr>
<td align="left">3</td>
<td align="left">Sabakzai Dam</td>
<td align="left">Zhob</td>
<td align="left">30.9461<sup>o</sup>N</td>
<td align="left">69.3621<sup>o</sup>E</td>
<td align="left">1,584</td>
<td align="left">Zone C</td>
<td align="left">Cold in winter, hot in summer</td>
</tr>
<tr>
<td align="left">4</td>
<td align="left">Guddu Barrage</td>
<td align="left">Kashmore</td>
<td align="left">28.4191<sup>o</sup>N</td>
<td align="left">69.7110<sup>o</sup>E</td>
<td align="left">93</td>
<td align="left">Zone D</td>
<td align="left">Dry and Hot</td>
</tr>
<tr>
<td align="left">5</td>
<td align="left">Mirani dam</td>
<td align="left">Makran</td>
<td align="left">25.9676<sup>o</sup>N</td>
<td align="left">62.7379<sup>o</sup>E</td>
<td align="left">53</td>
<td align="left">Zone E</td>
<td align="left">Warm and humid</td>
</tr>
</tbody>
</table>
</table-wrap>
<sec id="s4-1">
<title>4.1 Simulation tools</title>
<p>PVsyst is the most widely used simulation tool for assessing energy production and designing optimal solar power systems. It uses data on meteorological irradiation resources and PV system components, as well as a lot of knowledge of PV technology. PVsyst may therefore help with PV system component comprehension and, as a result, system design. Many parameters affect PV system performance, including tilt angle, orientation, geographical location, PV panel type, and solar global horizontal irradiation. This is one of the most reliable strategies for enhancing PV plant design. This is the most comprehensive modeling tool for the design and economic analysis of PV power plants. The comprehensive flow for PVsyst software&#x2019;s simulation technique is depicted in <xref ref-type="fig" rid="F2">Figure 2A, B</xref> shows the cross-functional methodology of the carried research.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<bold>(A)</bold> PVsyst simulation framework. <bold>(B)</bold> Cross-Functional Methodology of the proposed 2.5&#xa0;MW FPV plants at five climatic zones.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g002.tif"/>
</fig>
</sec>
<sec id="s4-2">
<title>4.2 IEC standards</title>
<p>
<xref ref-type="table" rid="T7">Table 7</xref> shows an overview of performance parameters for IEC 61724. IEC 61724 standards were established by the International Electrotechnical Commission, and various countries throughout the world have adopted them to meet the quality values of their products. His standard specifies a method for assessing the performance of different types of on-grids, off-grid, and hybrid PV systems. IEC 61724 offers a consistent baseline for assessing PV plant performance across geographies. According to the standard various measurements, such as irradiance, ambient temperature, wind speed, module temperature, voltage, current, and most importantly developed electricity measurement, are required for accurate performance evaluation of the PV system. All these measurements must be done with a precision of 1%&#x2013;2% and these quantities must be measured within a sample period of fewer than 10&#xa0;min (<xref ref-type="bibr" rid="B55">Srivastava et al., 2020</xref>).</p>
<table-wrap id="T7" position="float">
<label>TABLE 7</label>
<caption>
<p>Performance parameters (PPs).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">PPs</th>
<th align="left">Description</th>
<th align="center">Equations</th>
<th align="center">Unit</th>
<th align="center">Ref.</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">
<inline-formula id="inf4">
<mml:math id="m4">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The ratio of total absorbed solar radiation to the reference solar radiation.</td>
<td align="center">
<inline-formula id="inf5">
<mml:math id="m5">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>H</mml:mi>
<mml:mi>t</mml:mi>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>G</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B2">Ahmed et al. (2021)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf6">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">It is a ratio of daily, monthly, and yearly DC energy generated to the nominal power.</td>
<td align="center">
<inline-formula id="inf7">
<mml:math id="m7">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B2">Ahmed et al. (2021)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf8">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The ratio of daily, monthly, and yearly AC energy generated to the nominal power.</td>
<td align="center">
<inline-formula id="inf9">
<mml:math id="m9">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B2">Ahmed et al. (2021)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf10">
<mml:math id="m10">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Reference yield that is corrected by the effect of the PV panel&#x2019;s temperature</td>
<td align="center">
<inline-formula id="inf11">
<mml:math id="m11">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x3b3;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B19">Elhadj Sidi et al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf12">
<mml:math id="m12">
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>U</mml:mi>
<mml:mi>F</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The ratio of actual energy produced by the system to the energy at rated power.</td>
<td align="center">
<inline-formula id="inf13">
<mml:math id="m13">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>8760</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">%</td>
<td align="center">
<xref ref-type="bibr" rid="B50">Sharma and Goel (2017)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf14">
<mml:math id="m14">
<mml:mrow>
<mml:mi mathvariant="italic">PR</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The ratio of final yield to reference yield</td>
<td align="center">
<inline-formula id="inf15">
<mml:math id="m15">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">%</td>
<td align="center">
<xref ref-type="bibr" rid="B50">Sharma and Goel (2017)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf16">
<mml:math id="m16">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The ratio of annual produced energy to nominal power. Indicates the operation performance.</td>
<td align="center">
<inline-formula id="inf17">
<mml:math id="m17">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW</td>
<td align="center">
<xref ref-type="bibr" rid="B2">Ahmed et al. (2021)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf18">
<mml:math id="m18">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b7;</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>y</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Product of inverter efficiency and PV module efficiency.</td>
<td align="center">
<inline-formula id="inf19">
<mml:math id="m19">
<mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mfrac>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:msub>
<mml:mi>H</mml:mi>
<mml:mi>t</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">%</td>
<td align="center">
<xref ref-type="bibr" rid="B60">Trillo-Montero et al. (2014)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf20">
<mml:math id="m20">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>T</mml:mi>
<mml:mi>h</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>m</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">PV module performance is affected by the temperature, which causes thermal losses.</td>
<td align="center">
<inline-formula id="inf21">
<mml:math id="m21">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x3b3;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">MWh</td>
<td align="center">
<xref ref-type="bibr" rid="B19">Elhadj Sidi et al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf22">
<mml:math id="m22">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Array operation at its nominal power then losses are represented by array capture loss.</td>
<td align="center">
<inline-formula id="inf23">
<mml:math id="m23">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B19">Elhadj Sidi et al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf24">
<mml:math id="m24">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>m</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The sum of all losses other than module temperature increase like soiling, shading, module degradation, wiring loss, diode losses, and MPPT error.</td>
<td align="center">
<inline-formula id="inf25">
<mml:math id="m25">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B60">Trillo-Montero et al. (2014)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf26">
<mml:math id="m26">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>t</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Losses occur when the cell operates above STC.</td>
<td align="center">
<inline-formula id="inf27">
<mml:math id="m27">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B60">Trillo-Montero et al. (2014)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf28">
<mml:math id="m28">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The output of the PV array is affected by temperature, corrected by considering max. Power temperature coefficient.</td>
<td align="center">
<inline-formula id="inf29">
<mml:math id="m29">
<mml:mrow>
<mml:mfrac>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>&#x3b3;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>25</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh</td>
<td align="center">
<xref ref-type="bibr" rid="B16">Congedo et al. (2013)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf30">
<mml:math id="m30">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">As the temperature increased the power output of the PV module decreased by 0.4%&#x2013;0.5% at STC.</td>
<td align="center">
<inline-formula id="inf31">
<mml:math id="m31">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>d</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="left">
<xref ref-type="bibr" rid="B16">Congedo et al. (2013)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf32">
<mml:math id="m32">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Losses are generated during the DC-AC conversion process of the inverter.</td>
<td align="center">
<inline-formula id="inf33">
<mml:math id="m33">
<mml:mrow>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>Y</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">kWh/kW/day</td>
<td align="center">
<xref ref-type="bibr" rid="B60">Trillo-Montero et al. (2014)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf34">
<mml:math id="m34">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b7;</mml:mi>
<mml:mrow>
<mml:mi>t</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>m</mml:mi>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">Calculated by considering the temperature factor &#x3b2; and cell temperature of the PV panel.</td>
<td align="center">
<inline-formula id="inf35">
<mml:math id="m35">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>&#x3b2;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>C</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>25</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">Dimensionless Quantity</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Ibrik (2020)</xref>
</td>
</tr>
<tr>
<td align="left">
<inline-formula id="inf36">
<mml:math id="m36">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="left">The temperature on the surface of the PV module. Exceed the ambient temperature at the full sun but remain the same as an ambient temp. at night.</td>
<td align="center">
<inline-formula id="inf37">
<mml:math id="m37">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>a</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>d</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mn>800</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>c</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>20</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<sup>o</sup>C</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Ibrik (2020)</xref>
</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s4-3">
<title>4.3 Climatic conditions of sites</title>
<p>Given South Asia&#x2019;s usual weather pattern, it is necessary to assess the following site-related climatic factors including solar irradiance, wind speed, and ambient temperature to guarantee that FPV platforms endure as long as they&#x2019;re needed. These factors should be assessed with comprehensive detail since they have strong relations with the final output production and performance parameters of FPV plants.<list list-type="simple">
<list-item>
<p>1. Maximum wind speed</p>
</list-item>
<list-item>
<p>2. Maximum velocity of the water current</p>
</list-item>
<list-item>
<p>3. Maximum wave height and frequency</p>
</list-item>
<list-item>
<p>4. The composition and quality of the water (to assess corrosion risk)</p>
</list-item>
</list>
</p>
<p>The climatic data utilized in this investigation are taken from weather station Meteonorm 8.0 (PVsyst). <xref ref-type="table" rid="T8">Table 8</xref> summarizes different parameters like wind speed, storage capacity, global horizontal irradiance, horizontal diffused irradiance, and ambient temperature for selected sites.</p>
<table-wrap id="T8" position="float">
<label>TABLE 8</label>
<caption>
<p>Storage capacity, wind speed, GHI, Horizontal Diffused Irradiance, and temperature of selected sites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Sr. N</th>
<th align="center">Reservoirs</th>
<th align="center">Storage capacity (acre-ft)</th>
<th align="center">Wind speed (m/s)</th>
<th align="center">GHI (kWh/m<sup>2</sup>/day)</th>
<th align="center">Clearing index</th>
<th align="center">HDI (kWh/m<sup>2</sup>/day)</th>
<th align="center">Ambient temperature (<sup>o</sup>C)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">1</td>
<td align="left">Tarbela Dam</td>
<td align="center">11,098,664</td>
<td align="center">2.9</td>
<td align="center">4.96</td>
<td align="center">0.553</td>
<td align="center">2.15</td>
<td align="center">22.1</td>
</tr>
<tr>
<td align="left">2</td>
<td align="left">Ghazi Barotha Dam</td>
<td align="center">40,535.7</td>
<td align="center">2.6</td>
<td align="center">4.66</td>
<td align="center">0.548</td>
<td align="center">2.25</td>
<td align="center">22.2</td>
</tr>
<tr>
<td align="left">3</td>
<td align="left">Sabakzai Dam</td>
<td align="center">32,700</td>
<td align="center">2.2</td>
<td align="center">5.51</td>
<td align="center">0.631</td>
<td align="center">1.74</td>
<td align="center">19.9</td>
</tr>
<tr>
<td align="left">4</td>
<td align="left">Guddu Barrage</td>
<td align="center">--</td>
<td align="center">1.0</td>
<td align="center">4.96</td>
<td align="center">0.554</td>
<td align="center">2.51</td>
<td align="center">26.3</td>
</tr>
<tr>
<td align="left">5</td>
<td align="left">Mirani Dam</td>
<td align="center">302,396</td>
<td align="center">2.2</td>
<td align="center">5.37</td>
<td align="center">0.589</td>
<td align="center">2.42</td>
<td align="center">26.4</td>
</tr>
</tbody>
</table>
</table-wrap>
<sec id="s4-3-1">
<title>4.3.1 Wind speed effect on FPVs</title>
<p>Because the structure will rotate and move as a result of the wind, wind speed influences generation efficiency. To ensure the dependable and safe operation of an FPV system under extreme weather conditions, all extraneous conducting parts (e.g., PV module frames, structural metal, and junction boxes) should be bonded and grounded to the water surface. Any maintenance work on FPV should be avoided during rain or storms since the internal lightning protection system largely supports equipment and conducting components. <xref ref-type="fig" rid="F3">Figure 3</xref> depicts the monthly average wind speed (m/s) at five different locations. At various turbulence intensities of wind, the first row of the floating solar panels displayed the highest drag and lift coefficients. Due to the first row of solar panels&#x2019; wind-shielding properties, the drag and lift coefficients of the solar panel array steadily reduced along the direction of the wind. Additionally, the turbulent kinetic energy enhanced the drag and lift pressures on the solar panels, particularly for the first row of panels. A distinct flow and recirculating zone was created behind the first row of solar panels as a result of wind pressure impinging on them. Due to the first row&#x2019;s shielding effect, the wind speed gradually dropped as it moved down the solar panel array. Therefore, while designing an FPV system, the pressure on the first row of solar panels is crucial (<xref ref-type="bibr" rid="B14">Choi et al., 2021</xref>).</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Monthly average metrological data; wind speed (left), ambient temperature (middle), and global solar irradiance (right) for five selected sites of respective zones.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g003.tif"/>
</fig>
</sec>
<sec id="s4-3-2">
<title>4.3.2 Ambient temperature</title>
<p>PV modules are tested at a temperature of 25&#xb0;C (STC), and heat can lower output efficiency by 10%&#x2013;25% depending on the installed location. The output current of the solar panel increases exponentially as the temperature of the panel rises, whereas the voltage output decreases linearly which decreases the overall performance ratio (PR) of the system. High temperature significantly increases the heating effects within solar cells which alternately produces a thermal loss in the overall solar panel. These thermal losses further decrease the overall efficiency of a PV system. Because of the water surface, the ambient temperature of FPV always remains lower than LPVs, and the key advantage of FPV power plants is their PR, which is boosted by 5%&#x2013;10% over traditional photovoltaic plants due to the natural cooling effect of the water (<xref ref-type="bibr" rid="B32">Kjeldstad et al., 2021</xref>). <xref ref-type="fig" rid="F3">Figure 3</xref> illustrates the ambient temperature profiles for five selected sites of the respective zones. The parameterization and conditions of sites with relevant details are shown in section 1 (sub-section 1.1) in the <xref ref-type="sec" rid="s12">Supplymentry section</xref>.</p>
</sec>
</sec>
<sec id="s4-4">
<title>4.4 Project layout</title>
<p>The bottom-to-top versions of the intended 2.5&#xa0;MW FPV system are shown in <xref ref-type="sec" rid="s12">Supplymentary Figure S3</xref>. There are a total of 379 strings that are joined in a parallel arrangement where each string contains 22 series configured panels with 12 combiner boxes. A DC-AC inverter is linked in a series manner with combiner boxes and its role is to convert DC electrical input to AC. At the substation level, a network of underground cables is built to transport the power. Even though underground transmission infrastructure is more expensive than over-head, due to trains and land topologies, an underground transmission network is regarded as more reliable than an over-head transmission network in this scenario. The total required area (<inline-formula id="inf38">
<mml:math id="m38">
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) for the FPV plant can be calculated by evaluating Eq. <xref ref-type="disp-formula" rid="e1">1</xref> (<xref ref-type="bibr" rid="B2">Ahmed et al., 2021</xref>).<disp-formula id="e1">
<mml:math id="m39">
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>M</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>S</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mi>h</mml:mi>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
</p>
<p>Where N<sub>M</sub> is the number of the module, N<sub>S</sub> is the number of strings, S<sub>R</sub> is the spacing between rows, and <inline-formula id="inf39">
<mml:math id="m40">
<mml:mrow>
<mml:mi>h</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the length of the panel (1.672&#xa0;m). The number of PV modules per string (<inline-formula id="inf40">
<mml:math id="m41">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>M</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) is calculated by evaluating Eq. <xref ref-type="disp-formula" rid="e2">2</xref> (<xref ref-type="bibr" rid="B54">Song and Choi, 2016</xref>).<disp-formula id="e2">
<mml:math id="m42">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi>N</mml:mi>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">max</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:mo>,</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">min</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:mo>.</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>
</p>
<p>Where <inline-formula id="inf41">
<mml:math id="m43">
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">max</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:mo>,</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is maximum MPPT voltage, <inline-formula id="inf42">
<mml:math id="m44">
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">min</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:mo>.</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is minimum MPPT voltage, and <inline-formula id="inf43">
<mml:math id="m45">
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the maximum voltage of the PV module. The number of PV modules in a specific string indicates the string size. The number of PV modules in a string is always connected in a series which adds the voltages together and maximizes the final output voltage of a system at the DC bus. Later these strings are connected in parallel to each other to maximize the system&#x2019;s overall current. Hence, finally, the output power of the system may be enhanced. Number of strings (<inline-formula id="inf44">
<mml:math id="m46">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>S</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) that will be configured in parallel with each other&#x2019;s; can be calculated by Eq. <xref ref-type="disp-formula" rid="e3">3</xref> (<xref ref-type="bibr" rid="B54">Song and Choi, 2016</xref>).<disp-formula id="e3">
<mml:math id="m47">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>S</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>M</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>
</p>
<p>Where P is the required power of the plant and <inline-formula id="inf45">
<mml:math id="m48">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the maximum power of the module. The number of inverters (<inline-formula id="inf46">
<mml:math id="m49">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>I</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) can be calculated by Eq. <xref ref-type="disp-formula" rid="e4">4</xref> (<xref ref-type="bibr" rid="B37">LONGi Solar LR6-60-HPB-300M solar panel, 2020</xref>). Where <inline-formula id="inf47">
<mml:math id="m50">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is DC to AC ratio. The spacing (<inline-formula id="inf48">
<mml:math id="m51">
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) between the arrays can be calculated by Eq. <xref ref-type="disp-formula" rid="e5">5</xref> (<xref ref-type="bibr" rid="B37">LONGi Solar LR6-60-HPB-300M solar panel, 2020</xref>).<disp-formula id="e4">
<mml:math id="m52">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>I</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>M</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>S</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>
<disp-formula id="e5">
<mml:math id="m53">
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>L</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="&#x7c;">
<mml:mrow>
<mml:mi mathvariant="italic">cos</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mi mathvariant="normal">&#x3f4;</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:mo>&#x2061;</mml:mo>
<mml:mi mathvariant="italic">sin</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mi mathvariant="normal">&#x3f4;</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#xd7;</mml:mo>
<mml:mo>&#x2061;</mml:mo>
<mml:mi mathvariant="italic">tan</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msup>
<mml:mn>23.5</mml:mn>
<mml:mi>o</mml:mi>
</mml:msup>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
<label>(5)</label>
</disp-formula>
</p>
<p>Where L is the width of the panel (0.991&#xa0;m), <inline-formula id="inf49">
<mml:math id="m54">
<mml:mrow>
<mml:msub>
<mml:mi>L</mml:mi>
<mml:mrow>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the Latitude of the location given in <xref ref-type="table" rid="T6">Table 6</xref> and <inline-formula id="inf50">
<mml:math id="m55">
<mml:mrow>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the tilt angle to avoid shadow given in <xref ref-type="table" rid="T8">Table 8</xref>.</p>
<p>For the optimal absorption of solar radiation and the highest energy production, the suggested tilt angle for the FPV project is closer to the optimal angle of the site. While for the optimal generation of energy, the optimum angle is kept closer to the latitude of the respective site. For simulation studies in various climatic zones, the fixed tilt angle is mostly considered a reliable option. When adjusted to the ideal tilt angle, FPV modules produce the maximum amount of energy. The flat PV string provides 43.5% less energy than the PV string set to the optimum tilt angle of the respective site. Despite the fact, that horizontally positioned panels may benefit from water cooling more due to their proximity to the water surface, they produced the least amount of energy. This can be explained by the fact that the tilt angle optimization impact is stronger than the cooling effect. Finally, for FPVs, setting the PV modules to their optimal tilt angle is also suggested. As a result, for FPVs, adjusting the PV modules to the appropriate tilt angle is advised (<xref ref-type="bibr" rid="B12">Central, 2016</xref>). In this research optimum tilt angles of the suggested sites are summarized in <xref ref-type="table" rid="T8">Table 8</xref> which was chosen in the current study through simulation in PVsyst for performance evaluation of the FPV system for the understudy site.</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s5">
<title>5 Results and discussions</title>
<p>In this section, a comparative technical analysis of 2.5&#xa0;MW solar plants in five climatic zones is offered. Furthermore, a techno-environmental analysis for each case in the specific site is described in detail. In the first fold, based on PR and specific production (SP) technical analysis of a 2.5&#xa0;MW FPV plant for each under-study zone is carried out (<xref ref-type="bibr" rid="B54">Song and Choi, 2016</xref>; <xref ref-type="bibr" rid="B44">Pasalic et al., 2018</xref>). In the second fold, an economic analysis is carried out based on NPV, LCOE, PBP, etc. Similarly, in the third and fourth fold, environmental and social analyses are carried out based on balanced GHG emissions and the SDGs set by United Nations member states, respectively (<xref ref-type="bibr" rid="B20">El Hammoumi et al., 2021</xref>).</p>
<sec id="s5-1">
<title>5.1 Simulation tools</title>
<p>In the design process of FPVS using PVsyst simulation tool, various loss types are addressed to ensure a comprehensive and accurate representation of the system&#x2019;s performance. Here is a detailed explanation of how each of these losses is considered includes incidence angle modifier (IAM) losses, soiling losses, irradiance losses, thermal losses, module quality losses, mismatch losses, module degradation loss, ohmic wiring losses and auxiliaries consumption: The details are shown in Section 2 of the <xref ref-type="sec" rid="s12">Supplementary Material</xref>.</p>
<p>By incorporating these various loss types, PVsyst provides a comprehensive tool for engineers and designers to assess the performance of floating PV systems. This enables more accurate energy yield predictions and informed decision-making in system design and optimization.</p>
<p>For the performance evaluation of FPV, several parameters must be altered throughout the simulation shown in <xref ref-type="table" rid="T9">Table 9</xref>. One of these is albedo, which measures the amount of solar light reflected and ranges from 0 to 1. A dark body that absorbs all radiation has an albedo value of 1, whereas a body that reflects all irradiance has an albedo value of 0. The simulation uses a value of 0.2 albedo for LPV; however, because of the water surface, the value for FPV will be 0.06 (<xref ref-type="bibr" rid="B20">El Hammoumi et al., 2021</xref>). For this study, we are considering an albedo coefficient value of 0.06 to indicate the presence of water around FPV. In the literature, it is observed that the maximum value of albedo for the ocean is 10% while the minimum would be 0.05 (<xref ref-type="bibr" rid="B44">Pasalic et al., 2018</xref>). Albedo coefficient can be calculated by Eq. <xref ref-type="disp-formula" rid="e6">6</xref>.<disp-formula id="e6">
<mml:math id="m56">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>D</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b8;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>D</mml:mi>
<mml:mover accent="true">
<mml:mover accent="true">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
<label>(6)</label>
</disp-formula>
</p>
<table-wrap id="T9" position="float">
<label>TABLE 9</label>
<caption>
<p>Parameters of FPV in the simulation tool (<xref ref-type="bibr" rid="B27">Haas et al., 2020</xref>; <xref ref-type="bibr" rid="B44">Pasalic et al., 2018</xref>; <xref ref-type="bibr" rid="B54">Song and Choi, 2016</xref>).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Parameters in PVsyst</th>
<th align="center">Values for simulation</th>
<th align="center">Values range</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Albedo</td>
<td align="center">0.06</td>
<td align="center">0.05&#x2013;0.10</td>
</tr>
<tr>
<td align="center">U-value</td>
<td align="center">50</td>
<td align="center">70&#x2013;80</td>
</tr>
<tr>
<td align="center">Soiling loss</td>
<td align="center">1%</td>
<td align="center">1%&#x2013;3%</td>
</tr>
<tr>
<td align="center">Discount rate</td>
<td align="center">9.75%</td>
<td align="center">As per country (SBP)</td>
</tr>
<tr>
<td align="center">Inflation rate</td>
<td align="center">8.5%</td>
<td align="center">As per country (SBP)</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Where <inline-formula id="inf51">
<mml:math id="m57">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b8;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the solar zenith angle, <inline-formula id="inf52">
<mml:math id="m58">
<mml:mrow>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b8;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> is the directional-hemispherical reflectance, <inline-formula id="inf53">
<mml:math id="m59">
<mml:mrow>
<mml:mover accent="true">
<mml:mover accent="true">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula> bi-hemispherical reflectance, (1-D) is the proportion of direct radiation, D is the proportion of diffused illumination, and <inline-formula id="inf54">
<mml:math id="m60">
<mml:mrow>
<mml:mi>&#x3b1;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the actual albedo. When compared to standard terrestrial PV, which has a constant loss factor (<inline-formula id="inf55">
<mml:math id="m61">
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) of 20&#x2013;30&#xa0;W/m<sup>2</sup> K, FPV has a constant loss factor (<inline-formula id="inf56">
<mml:math id="m62">
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) of 70&#x2013;80&#xa0;W/m<sup>2</sup> K (<xref ref-type="bibr" rid="B16">Congedo et al., 2013</xref>). It has been measured at 86.5&#xa0;W/m<sup>2</sup> K when the FPV is mounted horizontally on a membrane with less than 1&#xa0;mm thickness, yet in the PVsyst simulation tool, the U-value cannot surpass 50&#xa0;W/m<sup>2</sup> K (<xref ref-type="bibr" rid="B54">Song and Choi, 2016</xref>). However, if the FPV system is in direct contact with water, the U-value will be around 70&#x2013;80&#xa0;W/m<sup>2</sup> K.</p>
</sec>
<sec id="s5-2">
<title>5.2 Technical analysis</title>
<p>Capacity utilization factor, system production, specific production, and array losses are the fundamental evaluation parameters for technical analysis. The results for these technical parameters for all five selected sites are summarized in <xref ref-type="table" rid="T10">Table 10</xref>. The analysis results of the on-grid FPV system in five zones revealed that the Zone C&#xa0;dam received the highest solar radiation, with an average of 7.18&#xa0;kWh/m<sup>2</sup> during June. While Zone B&#xa0;dam has the lowest solar radiation intensity, with an average of 2.6&#xa0;kWh/m<sup>2</sup> during December. The power output at Zone C&#xa0;dam is rather high as compared to other sites, based on solar insulation values for five selected Zones. <xref ref-type="fig" rid="F2">Figures 2</xref>, <xref ref-type="fig" rid="F3">3</xref> depicts the monthly average global horizontal solar irradiance (<inline-formula id="inf57">
<mml:math id="m63">
<mml:mrow>
<mml:mi>k</mml:mi>
<mml:mi>W</mml:mi>
<mml:mi>h</mml:mi>
<mml:mo>/</mml:mo>
<mml:msup>
<mml:mi>m</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula>) at five different locations. Irradiance and module temperature are regarded as decision variables while calculating system output. Eq. <xref ref-type="disp-formula" rid="e7">7</xref> is used to compute output power (<inline-formula id="inf58">
<mml:math id="m64">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>f</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) of the FPV system. From the below relation, it is clear that the final output of FPV has a strong relation with atmospheric pressure. Since the cell temperature (<inline-formula id="inf59">
<mml:math id="m65">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) is highly dependent on the ambient temperature.<disp-formula id="e7">
<mml:math id="m66">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>f</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>0.0024851</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>G</mml:mi>
<mml:mi>t</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>0.0019761</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>0.0141039</mml:mn>
</mml:mrow>
</mml:math>
<label>(7)</label>
</disp-formula>
</p>
<table-wrap id="T10" position="float">
<label>TABLE 10</label>
<caption>
<p>Major Technical Analysis results of five selected sites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameters</th>
<th align="center">Tarbela dam</th>
<th align="center">Ghazi barotha</th>
<th align="center">Sabakzai dam</th>
<th align="center">Guddu barrage</th>
<th align="center">Mirani dam</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">System Production (MWh/year)</td>
<td align="center">4,109</td>
<td align="center">3,926</td>
<td align="center">4,820</td>
<td align="center">4,084</td>
<td align="center">4,475</td>
</tr>
<tr>
<td align="left">Specific Production (kWh/kWp/year)</td>
<td align="center">1,643</td>
<td align="center">1,570</td>
<td align="center">1927</td>
<td align="center">1,633</td>
<td align="center">1788</td>
</tr>
<tr>
<td align="left">Array Losses (kWh/kWp/day)</td>
<td align="center">0.59</td>
<td align="center">0.56</td>
<td align="center">0.66</td>
<td align="center">0.66</td>
<td align="center">0.7</td>
</tr>
<tr>
<td align="left">Capacity Utilization Factor (CUF)</td>
<td align="center">0.1876</td>
<td align="center">0.1792</td>
<td align="center">0.2200</td>
<td align="center">0.1864</td>
<td align="center">0.2043</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Where T<sub>c</sub> is module temperature (<sup>o</sup>C), and G<sub>t</sub> is the solar irradiance (W/m<sup>2</sup>). The temperature of the module and air-water mixture should be examined because the temperature has a direct impact on the FPV power outcome. <xref ref-type="fig" rid="F4">Figure 4A</xref> depicts the average monthly energy production by a 2.5&#xa0;MW FPV plant at five under-study climatic zones. The lowest energy production for Zone B Dam was 227.3&#xa0;MWh experienced in February, while the highest was 395.8&#xa0;MWh in May. The Zone C&#xa0;dam produced the least amount of electricity (333.4&#xa0;MWh) in February and the highest amount of energy (455.5&#xa0;MWh) in October. The lowest energy production was 244.9&#xa0;MWh in February and the highest was 406.4&#xa0;MWh in May at Zone A&#xa0;dam. The Zone D dam produced the least energy (277.6&#xa0;MWh) in January and the highest energy (384.7&#xa0;MWh) in May. The minimum energy produced at Zone E&#xa0;dam was 305.6&#xa0;MWh in February and the highest was 408.5&#xa0;MWh in October. <xref ref-type="fig" rid="F4">Figure 4B</xref> displays the percentage of annual energy output in chosen zones; Zone B Dam has the least energy production (3,926&#xa0;MWh) while Zone C&#xa0;dam has the highest (4,820&#xa0;MWh). <xref ref-type="table" rid="T11">Table 11</xref> compares the major technical analysis simulation results for all investigated locations at their respective zones. A mathematical relation given in Eq. <xref ref-type="disp-formula" rid="e8">8</xref> can be used to compute the system&#x2019;s specific production.<disp-formula id="e8">
<mml:math id="m67">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>V</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>y</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi mathvariant="italic">max</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(8)</label>
</disp-formula>
</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>
<bold>(A)</bold> Energy injected into the grid of five selected sites. <bold>(B)</bold> Grid injected share of annual energy output in the percentage of five under-study sites of respective zones.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g004.tif"/>
</fig>
<table-wrap id="T11" position="float">
<label>TABLE 11</label>
<caption>
<p>Optimum tilt angles for a selected solar panel at each under-study site.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Sites</th>
<th align="center">Zone A</th>
<th align="center">Zone B</th>
<th align="center">Zone C</th>
<th align="center">Zone D</th>
<th align="center">Zone E</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Tilt angle</td>
<td align="center">32<sup>o</sup>
</td>
<td align="center">31<sup>o</sup>
</td>
<td align="center">32<sup>o</sup>
</td>
<td align="center">26<sup>o</sup>
</td>
<td align="center">26<sup>o</sup>
</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>In the above relationship, <inline-formula id="inf60">
<mml:math id="m68">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the number of PV panels while <inline-formula id="inf61">
<mml:math id="m69">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi mathvariant="italic">max</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the generated power by the PV module (W). The specific production is determined by the weather and the orientation of the panels. It is the ratio of FPV energy to DC installed at a certain period. One of the technical elements used to locate a feasible location for the installation of FPV is the installed peak power (<inline-formula id="inf62">
<mml:math id="m70">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) and the conversion efficiency (<inline-formula id="inf63">
<mml:math id="m71">
<mml:mrow>
<mml:mi>E</mml:mi>
<mml:mo>.</mml:mo>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) of the FPV plant. Eq. <xref ref-type="disp-formula" rid="e10">10</xref> and Eq. <xref ref-type="disp-formula" rid="e11">11</xref> can be used to compute them. Where <inline-formula id="inf64">
<mml:math id="m72">
<mml:mrow>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>V</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the PV panel area, while <inline-formula id="inf65">
<mml:math id="m73">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b7;</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the efficiency at STC.<disp-formula id="e10">
<mml:math id="m74">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>H</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>V</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>&#x3b7;</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(10)</label>
</disp-formula>
<disp-formula id="e11">
<mml:math id="m75">
<mml:mrow>
<mml:mi>E</mml:mi>
<mml:mo>.</mml:mo>
<mml:mi>E</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi mathvariant="italic">max</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>V</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:mrow>
</mml:math>
<label>(11)</label>
</disp-formula>
</p>
<p>Where S is the solar radiation intensity incident expressed in (W/m<sup>2</sup>). According to PVsyst simulation results, the required module area for a 2.5&#xa0;MW FPV plant is 13,816&#xa0;m<sup>2</sup>. The CUF also termed as capacity factor indicates the relationship between actual energy generated at a rated capacity of a system, calculated by Eq. <xref ref-type="disp-formula" rid="e12">12</xref>.<disp-formula id="e12">
<mml:math id="m76">
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>U</mml:mi>
<mml:mi>F</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>8760</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(12)</label>
</disp-formula>
</p>
<p>Where <inline-formula id="inf66">
<mml:math id="m77">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> are the produced energy in MWh and 8,760 are the total hours in a year. Due to the highest yearly energy production, the Zone C&#xa0;dam has the highest CUF (see <xref ref-type="table" rid="T11">Table 11</xref>). Due to the lowest yearly energy production, the Zone B Dam has the lowest CUF.</p>
<p>
<xref ref-type="fig" rid="F5">Figure 5</xref> shows the comparative relation between different techno-economic and performance parameters of all five selected sites. Relationship indicating a direct relation of CUF with system production. Zone C dam experiences the highest CUF of 22% since it has the highest system production of an overall 4,820&#xa0;MWh/year. In contrast, the Zone B Dam has the lowest overall system production that&#x2019;s why it receives the lowest CUF of 17.92%.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Comparative analysis of different techno-economic and performance parameters of all under-study five sites.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g005.tif"/>
</fig>
</sec>
<sec id="s5-3">
<title>5.3 Economic analysis</title>
<p>Although RE has some integration problems, it improves the voltage stability of the electrical network. Because the number of installations has increased, there has been a progressive growth in the integration of PV energy during the past few years. A solar panel is simply a collection of solar cells, therefore large solar panels are required to produce sufficient electricity. Because solar radiation occurs naturally, DC output is produced by PV arrays. Due to factors such as temperature, shade, dust, tilting, etc., solar cells lose some of their efficiency. It is anticipated that the price of a PV panel will reduce over time as this technology develops significantly.</p>
<p>In addition to expenditures, a full cost and profitability analysis of the FPV system should address the factors that directly impact energy output. Consider the economic aspects while evaluating the benefits of investing in FPV systems. Appropriate economic analyses, such as Levelized cost of energy (LCOE), Rate of Investment (ROI), Internal Rate of Return (IRR), and net present value (NPV) may ensure the profitability of installed FPV systems. Annual savings can be calculated by Eq. <xref ref-type="disp-formula" rid="e13">13</xref>.<disp-formula id="e13">
<mml:math id="m78">
<mml:mrow>
<mml:mtext>Annual&#x2009;Savings</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi mathvariant="normal">E</mml:mi>
<mml:mi mathvariant="normal">T</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mtext>FiT</mml:mtext>
</mml:mrow>
</mml:math>
<label>(13)</label>
</disp-formula>
</p>
<p>Where E<sub>T</sub> is the total energy supplied to the grid in kWh and <inline-formula id="inf67">
<mml:math id="m79">
<mml:mrow>
<mml:mtext>FiT</mml:mtext>
</mml:mrow>
</mml:math>
</inline-formula> is the feed-in tariff. The floating solar plant&#x2019;s annual savings are calculated using a feed-in tariff (<inline-formula id="inf68">
<mml:math id="m80">
<mml:mrow>
<mml:mtext>FiT</mml:mtext>
</mml:mrow>
</mml:math>
</inline-formula>) of 0.09 $/kWh. <xref ref-type="fig" rid="F6">Figure 6</xref> depicts the yearly net profit and cumulative cash flow of the proposed system at various sites. Return on investment (ROI) can be calculated by Eq. <xref ref-type="disp-formula" rid="e14">14</xref>. It is clear that ROI has an inverse relation to investment cost while a direct relation with final and initial values of investment. From <xref ref-type="fig" rid="F5">Figure 5</xref>, ROI shows a direct relation with the NPV of the system. As the NPV will be higher a system receives high initial expenditures and other operational costs which significantly reduce the rate to recover the initial investment of the system. At the same time, ROI shows also a direct relationship with the PR of the system. As the performance ratio of the system will be higher, higher will the rate of investment and hence lower will the payback time of the project.<disp-formula id="e14">
<mml:math id="m81">
<mml:mrow>
<mml:mtext>ROI</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">F</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi mathvariant="normal">I</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">C</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:mrow>
</mml:math>
<label>(14)</label>
</disp-formula>
<disp-formula id="e15">
<mml:math id="m82">
<mml:mrow>
<mml:mtext>LCOE</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
<mml:mi mathvariant="normal">n</mml:mi>
</mml:munderover>
</mml:mstyle>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mtext>INV</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi mathvariant="normal">O</mml:mi>
<mml:mo>&#x26;</mml:mo>
<mml:mi mathvariant="normal">M</mml:mi>
</mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mtext>Fuel</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="normal">r</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msup>
</mml:mfrac>
<mml:mo>&#x2212;</mml:mo>
<mml:mtext>salvage&#x2009;cost</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
<mml:mi mathvariant="normal">n</mml:mi>
</mml:munderover>
</mml:mstyle>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mtext>Energy</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="normal">r</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msup>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(15)</label>
</disp-formula>
</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Yearly net profit and cumulative cash flow <bold>(A)</bold> for Zone-A dam, <bold>(B)</bold> for Zone-B dam, <bold>(C)</bold> for Zone-C dam, <bold>(D)</bold> for Zone-D dam, and <bold>(E)</bold> for Zone-E dam.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g006.tif"/>
</fig>
<p>Where <inline-formula id="inf69">
<mml:math id="m83">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">F</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the final value of the investment, <inline-formula id="inf70">
<mml:math id="m84">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">I</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
<mml:mtext>the</mml:mtext>
</mml:mrow>
</mml:math>
</inline-formula> is the initial value of the investment, and <inline-formula id="inf71">
<mml:math id="m85">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">C</mml:mi>
<mml:mtext>inv</mml:mtext>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the cost of investment. Because the Zone C&#xa0;dam produces the most annual electricity, the data suggest that it has the best return on investment. The Zone B Dam has the lowest return on investment due to the lowest yearly energy generation, according to the study. The Levelized cost of energy produced from a solar plant over a specific time is referred to as the cost per unit (kWh). Eq. <xref ref-type="disp-formula" rid="e15">15</xref> can be used to compute the LCOE. Where <inline-formula id="inf72">
<mml:math id="m86">
<mml:mrow>
<mml:msub>
<mml:mtext>INV</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is an investment in year&#xa0;t, r is the discount rate, <inline-formula id="inf73">
<mml:math id="m87">
<mml:mrow>
<mml:msub>
<mml:mtext>Fuel</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the fuel cost in time t, <inline-formula id="inf74">
<mml:math id="m88">
<mml:mrow>
<mml:msub>
<mml:mtext>Energy</mml:mtext>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the energy produced in time t, and <inline-formula id="inf75">
<mml:math id="m89">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi mathvariant="normal">O</mml:mi>
<mml:mo>&#x26;</mml:mo>
<mml:mi mathvariant="normal">M</mml:mi>
</mml:mrow>
<mml:mi mathvariant="normal">t</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the operation and maintenance cost in a year&#xa0;t.</p>
<p>
<xref ref-type="table" rid="T12">Table 12</xref> includes the cost of system components like solar panels, inverters, wires, and so on, as well as installation, commissioning costs, and taxes. For all proposed plants in the chosen regions, the system costs are identical. The yearly operating cost including maintenance costs (salaries, repair, cleaning, and security fund) would be approximately $23250. The operation and maintenance costs of large-scale projects cannot be overlooked. It is important to mention here that the cost associated with land is not included in this analysis because, as previously stated, FPVs are installed on water bodies and hence land requirement holds no significance.</p>
<table-wrap id="T12" position="float">
<label>TABLE 12</label>
<caption>
<p>Cost detail of the FPV system.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Sr. No</th>
<th align="left">Item</th>
<th align="left">Quantity</th>
<th align="left">Unit Cost ($)</th>
<th align="left">Total Cost ($)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">1</td>
<td align="left">Land Cost</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">_</td>
</tr>
<tr>
<td align="left">2</td>
<td align="left">PV panel (LR6-60HPB-300M)</td>
<td align="left">8,338</td>
<td align="left">100</td>
<td align="left">833,800</td>
</tr>
<tr>
<td align="left">3</td>
<td align="left">Structure (Mounting, Pontoons, Anchors)</td>
<td align="left">8,338</td>
<td align="left">80</td>
<td align="left">667,040</td>
</tr>
<tr>
<td align="left">4</td>
<td align="left">Central Inverter (Sunny Centeral 800CP-JP)</td>
<td align="left">3</td>
<td align="left">20,833.33</td>
<td align="left">62,500</td>
</tr>
<tr>
<td align="left">5</td>
<td align="left">Installation cost (Installation of panels, inverter, transport)</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">30,333</td>
</tr>
<tr>
<td align="left">6</td>
<td align="left">Balance of System</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">16,934</td>
</tr>
<tr>
<td align="left">7</td>
<td align="left">Combiner Box</td>
<td align="left">12</td>
<td align="left">388</td>
<td align="left">4,656</td>
</tr>
<tr>
<td align="left">8</td>
<td align="left">Wiring (AC &#x26; DC Cables)</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">54,689</td>
</tr>
<tr>
<td align="left">9</td>
<td align="left">Other components (Surge Arresters, and monitoring system)</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">12,580</td>
</tr>
<tr>
<td align="left">10</td>
<td align="left">Insurance (Liability Insurance)</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">31,197</td>
</tr>
<tr>
<td align="left">11</td>
<td align="left">Taxes (VAT, Federal taxes, State taxes)</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">68,549.16</td>
</tr>
<tr>
<td align="left"/>
<td align="left">Grand Total</td>
<td align="left">_</td>
<td align="left">_</td>
<td align="left">1,782,278.16</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>PV module degradation and aging have a significant impact on the dependability and life of PV power facilities. The real degradation of PV modules is a source of concern for owners and other beneficiaries, as it has an impact on the power plant&#x2019;s financial outcome. The performance of FPV power plants and their degradation over time is investigated and results showed that it has an impact on financial factors as well; the Levelized cost of electricity (LCOE) is 2.5% higher than the LCOE computed with standard degradation (<xref ref-type="bibr" rid="B15">Coakley, 2003</xref>; <xref ref-type="bibr" rid="B47">Rosa-Clot and Tina, 2020</xref>; <xref ref-type="bibr" rid="B24">Goswami and Sadhu, 2021</xref>; <xref ref-type="bibr" rid="B35">Lindholm et al., 2021</xref>).</p>
<p>The internal rate of return (IRR) is a measure of a project&#x2019;s profitability. If the IRR is significant, the project will be more profitable in the long run. The IRR is directly proportional to the project&#x2019;s profitability when evaluating the value of money over time as shown in Eq. <xref ref-type="disp-formula" rid="e16">(16)</xref>.<disp-formula id="e16">
<mml:math id="m90">
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mi>R</mml:mi>
<mml:mi>R</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>h</mml:mi>
<mml:mi>f</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>w</mml:mi>
</mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msup>
</mml:mfrac>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(16)</label>
</disp-formula>
</p>
<p>The following Eq. <xref ref-type="disp-formula" rid="e16">16</xref> demonstrates and mathematical relation for calculating the IRR. Eq. <xref ref-type="disp-formula" rid="e17">17</xref> shows how to determine the net present value (NPV) of the after-tax cash flow of the FPV plant.<disp-formula id="e17">
<mml:math id="m91">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>V</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>n</mml:mi>
</mml:munderover>
</mml:mstyle>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msup>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(17)</label>
</disp-formula>
</p>
<p>Where <inline-formula id="inf76">
<mml:math id="m92">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the total cash inflow during the time &#x201c;<inline-formula id="inf77">
<mml:math id="m93">
<mml:mrow>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>&#x201d;. The complete results of the economic analysis of all five sites are summarized in <xref ref-type="table" rid="T13">Table 13</xref>. From <xref ref-type="fig" rid="F6">Figure 6</xref> a comparative analysis shows an inverse relation between LCOE and NPV. LCOE increases with an increase in the NPV of the project and <italic>vice versa</italic>. This is due to high operating costs, high initial expenditures, and system efficiency to produce the same amount of energy. For example, Sabakzai dam (Zone B) having the highest NPV of $17.1 million experiences the lowest LCOE i.e., 0.047 $/kWh. While, in contrast, Zone B Dam receives the highest LCOE i.e., 0.057 $/kWh due to the lowest NPV as compared to all other sites.</p>
<table-wrap id="T13" position="float">
<label>TABLE 13</label>
<caption>
<p>Performance analysis of all five under-study sites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameters</th>
<th align="center">Zone A dam</th>
<th align="center">Zone B dam</th>
<th align="center">Zone C dam</th>
<th align="center">Zone D dam</th>
<th align="center">Zone E dam</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Performance Ratio (%)</td>
<td align="center">85.1</td>
<td align="center">84.3</td>
<td align="center">85.6</td>
<td align="center">84.6</td>
<td align="center">84.9</td>
</tr>
<tr>
<td align="left">Normalized Production (kWh/kWp/day)</td>
<td align="center">4.50</td>
<td align="center">4.30</td>
<td align="center">5.28</td>
<td align="center">4.47</td>
<td align="center">4.90</td>
</tr>
<tr>
<td align="left">System Losses (kWh/kWp/day)</td>
<td align="center">0.20</td>
<td align="center">0.24</td>
<td align="center">0.23</td>
<td align="center">0.15</td>
<td align="center">0.17</td>
</tr>
<tr>
<td align="left">Payback Period (years)</td>
<td align="center">7.7</td>
<td align="center">8.3</td>
<td align="center">6.0</td>
<td align="center">7.8</td>
<td align="center">6.7</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>From an economic standpoint, <xref ref-type="fig" rid="F7">Figure 7</xref> shows that FPV can already compete with LPV [55-56]. As a result, while FPV deployment is already profitable, it may not be as profitable as LPV yet. Because of its early age, the cost of floating structures still plays a large role in FPV economics, but it is likely to decrease in the future. Furthermore, rising land costs may narrow the difference between FPV and LPV capital costs, favoring FPV installation. FPV prices are greater than conventional PV due to civil works, unique equipment, mounting, and floating structures. Because the FPV involves floating structures, mooring systems, and anchoring, the floating structures account for around a quarter of the total cost of installation. The costs associated with FPV are influenced by various general parameters including project location, water body height, water level variation, topography, plant size, and wind speed. The chosen anchoring structure is the most cost-effective in real projects since it is independent of the reservoir&#x2019;s geography and structure [56-57].</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Major components-wise cost analysis of LPV (left) and FPV (right) plants.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g007.tif"/>
</fig>
</sec>
<sec id="s5-4">
<title>5.4 Performance analysis</title>
<p>Here, performance ratio (PR), normalized production (NP), system losses (SL), and payback period (PBP) are considered evaluation indicators for performance analysis. NP and PR are the most relevant measures for comparing the performance of different sites.</p>
<p>
<xref ref-type="fig" rid="F8">Figure 8</xref> demonstrate that Zone C&#xa0;dam has the greatest normalized production with a PR of 85.6% and the shortest payback period (6 years) of the five locations that were chosen. Sabakzai Dam&#x2019;s normalized production and return on investment are higher, at 5.28 (kWh/kWp/day) and 99.3%, respectively. Zone B dam, on the other hand, has the lowest values for performance ratio, payback period, normalized production, and return on investment, with values of 84.3%, 8.3 years, 4.3 (kWh/kWp/day), and 57.5%, respectively. The detailed performance analysis for all five sites is summarized in <xref ref-type="table" rid="T14">Table 14</xref>. The PR of the system can be measured according to Eq. <xref ref-type="disp-formula" rid="e18">18</xref>.<disp-formula id="e18">
<mml:math id="m94">
<mml:mrow>
<mml:mi mathvariant="italic">PR</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>T</mml:mi>
</mml:msub>
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>T</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(18)</label>
</disp-formula>
</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Performance ratio and Normalized production; <bold>(A)</bold> for Zone A&#xa0;dam, <bold>(B)</bold> for Zone B&#xa0;dam, <bold>(C)</bold> for Zone C&#xa0;dam, <bold>(D)</bold> for Zone D dam, and <bold>(E)</bold> for Zone E&#xa0;dam, respectively.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g008.tif"/>
</fig>
<table-wrap id="T14" position="float">
<label>TABLE 14</label>
<caption>
<p>Performance analysis of all five under-study sites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameters</th>
<th align="center">Zone A dam</th>
<th align="center">Zone B dam</th>
<th align="center">Zone C dam</th>
<th align="center">Zone D dam</th>
<th align="center">Zone E dam</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Performance Ratio (%)</td>
<td align="center">85.1</td>
<td align="center">84.3</td>
<td align="center">85.6</td>
<td align="center">84.6</td>
<td align="center">84.9</td>
</tr>
<tr>
<td align="left">Normalized Production (kWh/kWp/day)</td>
<td align="center">4.50</td>
<td align="center">4.30</td>
<td align="center">5.28</td>
<td align="center">4.47</td>
<td align="center">4.90</td>
</tr>
<tr>
<td align="left">System Losses (kWh/kWp/day)</td>
<td align="center">0.20</td>
<td align="center">0.24</td>
<td align="center">0.23</td>
<td align="center">0.15</td>
<td align="center">0.17</td>
</tr>
<tr>
<td align="left">Payback Period (years)</td>
<td align="center">7.7</td>
<td align="center">8.3</td>
<td align="center">6.0</td>
<td align="center">7.8</td>
<td align="center">6.7</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Where E<sub>T</sub> is the total energy supplied to the grid in kWh, P<sub>o</sub> is the rated output power from FPV in kW, and I<sub>POA</sub> is the plane of array irradiance in <inline-formula id="inf78">
<mml:math id="m95">
<mml:mrow>
<mml:mi>k</mml:mi>
<mml:mi>W</mml:mi>
<mml:mo>/</mml:mo>
<mml:msup>
<mml:mi>m</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>T</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the irradiance under standard test conditions (<inline-formula id="inf79">
<mml:math id="m96">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>T</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1000</mml:mn>
<mml:mi>k</mml:mi>
<mml:mi>W</mml:mi>
<mml:mo>/</mml:mo>
<mml:msup>
<mml:mi>m</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula>). With 5.28&#xa0;kWh/kWp/day normalized production, the FPV plant has the best performance at Zone C&#xa0;dam since it is in the highest solar resource region. Sabakzai Dam&#x2019;s climatic conditions are ideal for FPV plant deployment, with an average ambient temperature of 19.95&#xb0;C, an average wind speed of 2.2&#xa0;m/s, and an average solar radiation of 5.51&#xa0;kWh/m<sup>2</sup>/day. Due to a normalized output of 4.30&#xa0;kWh/kWp/day and fewer favorable meteorological circumstances, plant energy production is the lowest in the Zone B Dam. The PBP is the amount of time it takes for a project&#x2019;s initial investments to be repaid from the revenue it generates. The payback method&#x2019;s main goal is to determine the likelihood of investment. The mathematical expression for calculating the PBP is described in Eq. <xref ref-type="disp-formula" rid="e19">19</xref>.<disp-formula id="e19">
<mml:math id="m97">
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>B</mml:mi>
<mml:mi>P</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>m</mml:mi>
</mml:msubsup>
</mml:mstyle>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mn>365</mml:mn>
</mml:msubsup>
</mml:mstyle>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mi>F</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(19)</label>
</disp-formula>
</p>
<p>Where m is the number of minimum years by which the total revenue of the system is larger than the total cost, <inline-formula id="inf80">
<mml:math id="m98">
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the total project costs, and <inline-formula id="inf81">
<mml:math id="m99">
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mi>F</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the annual net cash inflow-outflow.</p>
<p>All of the performance analysis&#x2019;s findings indicate that the 2.5&#xa0;MW FPV project&#x2019;s installation will be more advantageous at Sabakzai Dam than at Zone B&#xa0;dam. From <xref ref-type="fig" rid="F8">Figure 8</xref>, PBP shows an indirect relation with the PR. As the PR of the system increases, the time required to recover the investment on a project gets shorter. For example, Zone C&#xa0;dam has the highest PR i.e., 85.6%, consequently, it receives the lowest PBP of 6.0 years. In contrast, Zone B Dam experienced the highest PBP of 8.3 years due to its lowest PR of 84.3 as compared to all other four sites.</p>
</sec>
<sec id="s5-5">
<title>5.5 Environmental analysis</title>
<p>The FPV has been shown to have fewer negative consequences on the environment than the SPV. Because of their economic viability and environmental stability, FPVs help to maintain ecological equilibrium. The capacity of FPVs is 10.2% higher than that of LPVs, FPVs save a significant amount of coal while also lowering GHG emissions. Factors like GHG emissions, wind speed, waves on water, water temperature (<xref ref-type="bibr" rid="B1">Acharya and Devraj, 2019</xref>; <xref ref-type="bibr" rid="B41">Micheli, 2021</xref>), soiling, algae growth, water evaporation, and deforestation predict environmental feasibility. The reduction in water evaporation may be seen in an environmental analysis; for each megawatt of FPV installed capacity, roughly 1,500&#xa0;m<sup>3</sup>&#x2013;2000&#xa0;m<sup>3</sup> of water is saved from evaporation (<xref ref-type="bibr" rid="B48">Rosa-Clot et al., 2017</xref>; <xref ref-type="bibr" rid="B30">Jeong et al., 2020</xref>).</p>
<p>The exploration into the interplay between water, particularly humidity, and FPV systems reveals intriguing insights. Given that the development of FPV systems is still in early stages, the investigation is focused on discerning the unique performance characteristics of FPVs compared to their LBP counterparts. The key findings and observations from the literature are outlined as follows:</p>
<sec id="s5-5-1">
<title>5.5.1 Temperature Differential</title>
<p>The FPV system demonstrates a lower operating temperature compared to the LBP system, with a temperature difference of 7&#xa0;&#xb0;C. This indicates that the FSP system benefits from the cooling effect provided by the water surface.</p>
</sec>
<sec id="s5-5-2">
<title>5.5.2 Relative Humidity (RH) Influence</title>
<p>The FPV system exhibits higher relative humidity levels compared to the LBP system. This elevated humidity is identified as having an impact on the performance ratio (PR) of the FSP system. The interplay between humidity and system performance is a crucial aspect explored in the study.</p>
</sec>
<sec id="s5-5-3">
<title>5.5.3 Performance Ratio Impact</title>
<p>Despite the influence of relative humidity on the PR of the FSP system, the study notes that the FPV system outperforms the LPV system in terms of energy output. This suggests that, while humidity influences system performance, the FPV system&#x2019;s overall energy yield surpasses that of its land-based counterpart.</p>
<p>These insights into the nuanced relationship between water, humidity, and the performance of FPV systems provide a comprehensive understanding of the topic. The observed temperature reduction in the FSP system, attributed to its water-based operation, underscores the cooling benefits of the floating platform. Additionally, the impact of higher relative humidity on the performance ratio highlights the need for a thorough understanding of environmental factors in FPV system design (<xref ref-type="bibr" rid="B22">Goswami, 2023</xref>).</p>
<p>Changes in environmental conditions, such as temperature and solar radiation impact the parameters like resistance, saturation current, and ideality factor etc. Higher temperatures typically lead to an increase in saturation current and a decrease in resistance, affecting the overall performance. Additionally, solar radiation variations and humidity levels influence the ideality factor, contributing to the dynamic response of the floating solar module under different climatic conditions.</p>
<p>Potential Evapotranspiration (PET) is a method of calculating evapotranspiration from entirely submerged lakes and reservoirs, as well as specific sites with endless water sources. It is useful for figuring out how installations on the surface of water bodies affect climate change. PET values are useful for determining a region&#x2019;s atmospheric water requirement. It is measured in millimeters per day or millimeters per year. It can be determined using Eq. <xref ref-type="disp-formula" rid="e20">20</xref>.<disp-formula id="e20">
<mml:math id="m100">
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
<mml:mi>T</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="normal">k</mml:mi>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>0.165</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>216.7</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>h</mml:mi>
</mml:msub>
<mml:msup>
<mml:mrow>
<mml:mo>&#xd7;</mml:mo>
<mml:mi mathvariant="normal">e</mml:mi>
</mml:mrow>
<mml:mi mathvariant="normal">s</mml:mi>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="normal">T</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mn>273.3</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(20)</label>
</disp-formula>
</p>
<p>Where k is the proportionality constant, <inline-formula id="inf82">
<mml:math id="m101">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>h</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> are daylight hours, <inline-formula id="inf83">
<mml:math id="m102">
<mml:mrow>
<mml:msup>
<mml:mi mathvariant="normal">e</mml:mi>
<mml:mi mathvariant="normal">s</mml:mi>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula> is saturated vapor pressure, and T is air temperature. In literature, it is shown, that FPV plants save 1500&#xa0;m<sup>3</sup>/year of water for each hectare. Also, Eq. <xref ref-type="disp-formula" rid="e21">21</xref> and Eq. <xref ref-type="disp-formula" rid="e22">22</xref> show the mathematical relationship for calculating evaporation reduction efficiency for partially covered water bodies.<disp-formula id="e21">
<mml:math id="m103">
<mml:mrow>
<mml:mi>&#x190;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x3b1;</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mfrac bevelled="true">
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mn>3</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:msup>
</mml:mrow>
</mml:math>
<label>(21)</label>
</disp-formula>
<disp-formula id="e22">
<mml:math id="m104">
<mml:mrow>
<mml:mi>&#x3b3;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>,</mml:mo>
<mml:mn>0</mml:mn>
<mml:mo>&#x2264;</mml:mo>
<mml:mi mathvariant="normal">&#x3b1;</mml:mi>
<mml:mo>&#x2264;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:math>
<label>(22)</label>
</disp-formula>
</p>
<p>Where <inline-formula id="inf84">
<mml:math id="m105">
<mml:mrow>
<mml:mi>&#x190;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the evaporation reduction efficiency, <inline-formula id="inf85">
<mml:math id="m106">
<mml:mrow>
<mml:mi>&#x3b3;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the ratio of S<sub>c</sub> which is the partially covered surface area, and S which is the total area of the water reservoir. GHG emissions are damaging the environment because they absorb infrared radiation in the atmosphere. They should be eliminated from the atmosphere to have a healthy and clean environment. The burning of fossil fuels and human activities are to blame for raising the earth&#x2019;s temperature, a phenomenon known as global warming, which is affecting millions of people&#x2019;s lives. To eliminate GHG emissions, we must limit the use of fossil fuels. When considering the benefits of FPV, it is the greatest approach for reducing GHG emissions which contain a major portion of carbon emissions. Eq. (23-25) used to calculate the produced emissions (<inline-formula id="inf86">
<mml:math id="m107">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>), replaced emissions (<inline-formula id="inf87">
<mml:math id="m108">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>), and GHG emission balance (<inline-formula id="inf88">
<mml:math id="m109">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) respectively. It is important to mention here that emissions sound to only carbon (<inline-formula id="inf89">
<mml:math id="m110">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) emissions.<disp-formula id="e23">
<mml:math id="m111">
<mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mi>G</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:mi>C</mml:mi>
<mml:msub>
<mml:mi>O</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:mi>k</mml:mi>
<mml:mi>W</mml:mi>
<mml:mi>h</mml:mi>
</mml:mrow>
</mml:math>
<label>(23)</label>
</disp-formula>
<disp-formula id="e24">
<mml:math id="m112">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mi>G</mml:mi>
</mml:msub>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>F</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(24)</label>
</disp-formula>
<disp-formula id="e25">
<mml:math id="m113">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(25)</label>
</disp-formula>
</p>
<p>Where E<sub>F</sub> is the emission factor and A<sub>G</sub> is the annual energy generation. The results of the environmental analysis for five selected sites for the FPV plant are shown in <xref ref-type="table" rid="T15">Table 15</xref>. According to the table, the largest replaced emissions are found in the Zone C&#xa0;dam, while the lowest are found in the Zone B Dam. Similarly, Zone C&#xa0;dam has the highest emissions balance of saved CO<sub>2</sub> emission at 43125.7 tCO<sub>2</sub> while Zone B Dam has the lowest at 34283.8 tCO<sub>2</sub>. <xref ref-type="fig" rid="F9">Figure 9</xref> depicts the CO<sub>2</sub> emissions saved throughout lifetime of a project for all five selected sites of respective zones. In this study, only CO<sub>2</sub> emissions are considered for environmental analysis, because carbon emission is a major factor that contributes to almost 90% of overall pollution. In the proposed 2.5&#xa0;MW FPV systems, the major portion of the GHG emissions is associated with the manufacturing, installation, operation, and maintenance of the system.</p>
<table-wrap id="T15" position="float">
<label>TABLE 15</label>
<caption>
<p>Major Socio-Analysis outcomes of five selected sites (<xref ref-type="bibr" rid="B21">Exley et al., 2021</xref>).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">SDG</th>
<th align="center">Goal name</th>
<th align="center">Fact relevant to FPV plants</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">SDG-02</td>
<td align="center">Zero hunger</td>
<td align="center">Spare land for agricultural purposes</td>
</tr>
<tr>
<td align="center">SDG-03</td>
<td align="center">Good health</td>
<td align="center">90% of the population is suffering from air pollution</td>
</tr>
<tr>
<td align="center">SDG-04</td>
<td align="center">Quality education</td>
<td align="center">300 million children&#x2019;s primary schools are without electricity</td>
</tr>
<tr>
<td align="center">SDG-05</td>
<td align="center">Gender equality</td>
<td align="center">32% of 11.5 million employees are women</td>
</tr>
<tr>
<td align="center">SDG-06</td>
<td align="center">Clean water</td>
<td align="center">FPV improves water quality by reducing algae growth</td>
</tr>
<tr>
<td align="center">SDG-07</td>
<td align="center">Renewable energy</td>
<td align="center">789 million people are living without electricity facility</td>
</tr>
<tr>
<td align="center">SDG-08</td>
<td align="center">Good jobs and economic growth</td>
<td align="center">11.5 million people are serving in the renewable energy domain</td>
</tr>
<tr>
<td align="center">SDG-13</td>
<td align="center">Climate action</td>
<td align="center">17.1% of total energy is generated by renewable</td>
</tr>
<tr>
<td align="center">SDG-14</td>
<td align="center">Life below water</td>
<td align="center">Blue economy activities</td>
</tr>
<tr>
<td align="center">SDG-15</td>
<td align="center">Life on land</td>
<td align="center">FPV helps in green energy production which improves life on land through clean energy</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>CO<sub>2</sub> emissions balance <bold>(A)</bold> from Zone A&#xa0;dam, <bold>(B)</bold> from Zone B Dam, <bold>(C)</bold> from Zone C&#xa0;dam, <bold>(D)</bold> from Zone D dam, and <bold>(E)</bold> Zone E&#xa0;dam, respectively.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g009.tif"/>
</fig>
<p>An emission absorbing forests analysis is carried out in RETScreen Expert based on the amount of carbon emission balanced from the system in the presence of grid-connected operation mode. The forest absorbing areas are evaluated in hectares concerning balanced GHG emissions. RETScreen Expert offers an energy module that may be used to monitor residential energy usage for liquefied petroleum gas (LPG), biomass, diesel generators, and kerosene oil. Furthermore, an equivalent forest carbon-absorbing area is provided to absorb carbon emissions from such non-conventional energy resources (<xref ref-type="bibr" rid="B4">Ali et al., 2021</xref>). <xref ref-type="fig" rid="F10">Figure 10</xref> shows the land (hectares) required for forests to absorb carbon emissions concerning overall emissions balanced by each under-study site. As more carbon emissions are balanced, more area is required for the forest to absorb those carbon emissions. For example, Zone C dam showed the highest index of 43125.7 tons of emissions equivalent to 3924.439&#xa0;ha of forests absorbing carbon. In a nutshell, 189056.4 tons/year of emissions will be emitted from all five under-study sites, and about 17204.133&#xa0;ha of forests are required to absorb the emissions from all sites.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Land (hectares) required for forest absorbing balanced carbon emission for five under-study sites.</p>
</caption>
<graphic xlink:href="fenrg-12-1404777-g010.tif"/>
</fig>
<p>Bio soiling, especially from bird droppings, causes an increase in O&#x26;M costs as well as accelerates degradation. Solar panels require a lot of water to clean due to dust accumulation on the panels, yet there are few soiling losses and the FPV requires less water (<xref ref-type="bibr" rid="B30">Jeong et al., 2020</xref>). Before installation, a survey of bird species and numbers should be conducted. Natural cooling of water contributes to reducing cell degradation and maximizing lifetime. Because of the cooling impact of water, the average module temperature for FPV is 4.9% lower than with LPV, this is attributed to an increase in the power generation of FPV.</p>
<p>The efficiency of SPVs was severely reduced due to high temperatures; literature suggests that when the operating temperature of the panel hits 60&#xb0;C, the cell efficiency drops by 10%. Surface temperature influences the quality and performance of PV cells (<xref ref-type="bibr" rid="B34">Li et al., 2012</xref>; <xref ref-type="bibr" rid="B13">Chander et al., 2015</xref>). Several simple and dependable solutions have been developed for ground-mounted PVs to improve conversion efficiency by collecting thermal heat and keeping the surface temperature low (<xref ref-type="bibr" rid="B13">Chander et al., 2015</xref>; <xref ref-type="bibr" rid="B51">Siecker et al., 2017</xref>). Another advantage of FPV for the environment is that it reduces the erosion of reservoir embankments by lowering wave impact. Implementing such an FPV system on a nationwide basis would result in increased energy output.</p>
</sec>
</sec>
<sec id="s5-6">
<title>5.6 Socio analysis</title>
<p>Increased use of renewable energy resources is the only way to accomplish the SDGs, especially SDG-7. The best solution for sustainably producing green energy is probably FPV technology on underutilized water bodies because large-scale PV plants take up valuable land and hence prevent redevelopment. The FPV technique could improve the efficiency of the region&#x2019;s energy and water management. In dry and semiarid areas, integrating energy and water can improve long-term utilization and give societal benefits. FPV plants enhance the aesthetics, preserve important land for agriculture or other uses, and rehabilitate damaged areas while generating clean energy. There is a total of seventeen SDGs with the phrase &#x201c;leave no one behind,&#x201d; implying that the goal must be met by everyone. <xref ref-type="table" rid="T15">Table 15</xref> shows numbers, names, and relevance of the SDGs to FPV plants. In just 9&#xa0;years, 280 million people gained access to safe, affordable power and the positive influence can be seen in the fact that renewable energy replaces kerosene oil as a source of electricity 40% of the time. By 2050, an additional 350&#xa0;GW of ocean offshore renewable energy capacity is expected. Wind, tidal, thermal, waves, FPVs, and salinity gradient technology are all used in ocean offshore renewed energy.</p>
</sec>
<sec id="s5-7">
<title>5.7 Results validation and comparison</title>
<p>This study is novel in that it suggests the first FPV project because none have yet been developed for the specific Asian country. To prove that the suggested study is preferable to the LPV project, it is necessary to compare the simulated results of the Zone C&#xa0;dam with the actual results of the 2.5&#xa0;MW on-ground PV project installed for the cement factory at Fateh Jang. Renewable Stars Private Limited assists in the collection of real-time on-site data for the 2.5&#xa0;MW LPV system installed in Fateh Jang. <xref ref-type="table" rid="T15">Table 15</xref> displays the comparative analysis and detailed results validation. According to results validation and comparison, the proposed highest feasible FPV system has a significant edge over the on-ground PV system in terms of techno-economic, performance, and environmental indices.</p>
<p>According to collected data, the Fateh Jang project&#x2019;s efficiency is 13.8%. Sabakzai Dam, which is the most feasible location, has better CUF, final yield, normalized production, saved GHG emissions, and specific production than the Fateh Jang on-ground project. Sabakzai Dam&#x2019;s performance ratio is 6.4% greater than that of Fateh Jang Dam due to the system&#x2019;s increased production of 653&#xa0;MWh per year. FPV projects, however, have a higher project total cost than LPV systems which raises the payback period. These higher costs of FPV over PV systems are due to additional equipment expenditures during project installation. Since the initial capital cost of FPV is 18% higher as compared to the on-ground PV system, that&#x2019;s why the payback period of the FPV system increases by almost 43.33% as compared to the PV system. In addition, the proposed FPV system produces almost 1.5% more carbon emissions as compared to the on-ground PV system. This is due to the structure manufacturing of the FPV system which is mostly based on high-density polyethylene material which poses an additional carbon emission on the system as compared to the PV system. Kindly refer to <xref ref-type="table" rid="TA1">Table A1</xref> in the appendix section.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s6">
<title>6 Conclusion</title>
<p>In this study, a techno-economic and sustainability assessment analysis of a grid-connected FPV system is carried out for five different climate zones. Techno-economic and environmental analyses are carried out based on different decision indicators like PR, CUF, LCOE, NPV, PBP, ROI, and GHG emissions. Zone B dam appears to be the least feasible site with LCOE of $0.057/kWh and NPV of million $1.0256. On the other hand, Zone B&#xa0;dam is the most feasible location with LCOE of $0.047/kWh and NPV of million $1.7705. While socio analysis is carried out based on SDGs especially (SDGs 2-8 &#x26; 13-15). The detailed multi-dimensional analysis showed that all selected sites (dams and barrage) in respective climate regions are feasible for the installation of a 2.5&#xa0;MW FPV system. Zone C dam among all sites showed a better performance in terms of the proposed analysis. On the other hand, Zone B Dam showed the least feasible performance amongst all selected sites under the same evaluation criteria. The most practicable location is Zone C&#xa0;dam, which has a PR of 85.6% and a PBP of 6&#xa0;years. The least feasible site is Zone B&#xa0;dam, which has a PR of 84.3% and a PBP of 8.3&#xa0;years.</p>
<p>In addition, equivalent forest-absorbing carbon analysis has been carried out in RETScreen Expert software for each under-study climate zone. Results showed 43125.7 tons and 34283.8 tons of carbon emissions which are equivalent to 3924.439 and 3119.826&#xa0;ha of forest absorbing carbon for Zone C&#xa0;dam and Zone B Dam, respectively. The results of the proposed study are later validated with real-time data of the on-ground 2.5&#xa0;MW&#xa0;PV project in Fateh Jang, which shows a significant edge in techno-economic and performance parameters for FPV as compared to the LPV system. The 2.5&#xa0;MW FPV proposed system at Zone C&#xa0;dam has an 85.6% PR compared to the 2.5&#xa0;MW LPV existing system at Fateh Jang has a 79.2% PR, indicating that FPV performs better than LPV. The proposed study can be a decision pathway toward policy optimization for the installation of FPV technology. The current study is performed on manmade and artificial water bodies. In the future, the proposed study can be enhanced to other sites like industrial, agricultural, and offshore water bodies. In addition, a similar study can be performed on small-scale ponds and lacks local rural or off-grid communities. The proposed study can lead to policy recommendations for stakeholders toward investment in FPV sector.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s7">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s11">Supplementary Material</xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s8">
<title>Author contributions</title>
<p>AM: Conceptualization, Formal Analysis, Investigation, Methodology, Project administration, Software, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. SK: Conceptualization, Methodology, Project administration, Resources, Software, Supervision, Writing&#x2013;original draft, Writing&#x2013;review and editing. AA: Funding acquisition, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. ZK: Conceptualization, Formal Analysis, Investigation, Methodology, Project administration, Supervision, Validation, Writing&#x2013;original draft, Writing&#x2013;review and editing. SA: Conceptualization, Investigation, Project administration, Resources, Software, Supervision, Validation, Writing&#x2013;original draft, Writing&#x2013;review and editing.</p>
</sec>
<sec sec-type="funding-information" id="s9">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. The author extends the appreciation to the Deanship of Postgraduate Studies and Scientific Research at Majmaah University for funding this research work through the project number (R-2024-1111).</p>
</sec>
<sec sec-type="COI-statement" id="s10">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s11">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s12">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fenrg.2024.1404777/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fenrg.2024.1404777/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.pdf" id="SM1" mimetype="application/pdf" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Acharya</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Devraj</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2019</year>) <source>Floating solar photovoltaic (FSPV): a third pillar to solar PV sector ? teri discussion paper:output of the etc India project</source>. <publisher-loc>New Delhi</publisher-loc>: <publisher-name>The Energy and Resources Institute</publisher-name>, <fpage>68</fpage>.</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ahmed</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Naveed Khan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ahmed</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Aslam</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Imran</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Sajid</surname>
<given-names>M. B.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Techno-economic potential assessment of mega scale grid-connected PV power plant in five climate zones of Pakistan</article-title>. <source>Energy Convers. Manag.</source> <volume>237</volume>, <fpage>114097</fpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2021.114097</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Akole</surname>
<given-names>H. U.</given-names>
</name>
<name>
<surname>Jadhav</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2018</year>). &#x201c;<article-title>Floating solar plant</article-title>,&#x201d; in <source>2018 3rd international conference for convergence in technology, I2CT</source>, <fpage>493</fpage>&#x2013;<lpage>498</lpage>. <pub-id pub-id-type="doi">10.1109/I2CT.2018.8529479</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ali</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wazir</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Imran</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Ullah</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Janjua</surname>
<given-names>A. K.</given-names>
</name>
<name>
<surname>Ulasyar</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Techno-economic assessment and sustainability impact of hybrid energy systems in Gilgit-Baltistan, Pakistan</article-title>. <source>Energy Rep.</source> <volume>7</volume>, <fpage>2546</fpage>&#x2013;<lpage>2562</lpage>. <pub-id pub-id-type="doi">10.1016/j.egyr.2021.04.036</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ates</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Yilmaz</surname>
<given-names>O. S.</given-names>
</name>
<name>
<surname>Gulgen</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Using remote sensing to calculate floating photovoltaic technical potential of a dam&#x2019;s surface</article-title>. <source>Sustain. Energy Technol. Assessments</source> <volume>41</volume>, <fpage>100799</fpage>. <pub-id pub-id-type="doi">10.1016/j.seta.2020.100799</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bai</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Xiong</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Liao</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Assessment of floating solar photovoltaic potential in China</article-title>. <source>Renew. Energy</source> <volume>220</volume>, <fpage>119572</fpage>. <pub-id pub-id-type="doi">10.1016/j.renene.2023.119572</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bakar</surname>
<given-names>M. S. A.</given-names>
</name>
<name>
<surname>Nandong</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Technoeconomic analysis of floating solar field for 1 GWh of electricity generation</article-title>. <source>IOP Conf. Ser. Mater Sci. Eng.</source> <volume>495</volume>, <fpage>012064</fpage>. <pub-id pub-id-type="doi">10.1088/1757-899X/495/1/012064</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baptista</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Vargas</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ferreira</surname>
<given-names>J. R.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>A techno-economic analysis of floating photovoltaic systems, for southern european countries</article-title>. <source>Renew. Energy Power Qual. J.</source> <volume>19</volume>, <fpage>57</fpage>&#x2013;<lpage>62</lpage>. <pub-id pub-id-type="doi">10.24084/repqj19.214</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barbir</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Veziroglu</surname>
<given-names>T. N.</given-names>
</name>
<name>
<surname>Plass</surname>
<given-names>H. J.</given-names>
</name>
</person-group> (<year>1990</year>). <article-title>Environmental damage due to fossil fuels use</article-title>. <source>Int. J. Hydrogen Energy</source> <volume>15</volume>, <fpage>739</fpage>&#x2013;<lpage>749</lpage>. <pub-id pub-id-type="doi">10.1016/0360-3199(90)90005-j</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Campana</surname>
<given-names>P. E.</given-names>
</name>
<name>
<surname>W&#xe4;sthage</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Nookuea</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Tan</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Optimization and assessment of floating and floating-tracking PV systems integrated in on- and off-grid hybrid energy systems</article-title>. <source>Sol. Energy</source> <volume>177</volume>, <fpage>782</fpage>&#x2013;<lpage>795</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2018.11.045</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cazzaniga</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Cicu</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Rosa-Clot</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Rosa-Clot</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Tina</surname>
<given-names>G. M.</given-names>
</name>
<name>
<surname>Ventura</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Floating photovoltaic plants: performance analysis and design solutions</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>81</volume>, <fpage>1730</fpage>&#x2013;<lpage>1741</lpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2017.05.269</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Central</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2016</year>) <source>Sunny central 630CP-jp sunny central 630CP-jp the perfect solution for PV power plants in Japan sunny central 630CP-jp</source>.</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chander</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Purohit</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sharma</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Arvind</surname>
<given-names>N. S. P.</given-names>
</name>
<name>
<surname>Dhaka</surname>
<given-names>M. S.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>A study on photovoltaic parameters of mono-crystalline silicon solar cell with cell temperature</article-title>. <source>Energy Rep.</source> <volume>1</volume>, <fpage>104</fpage>&#x2013;<lpage>109</lpage>. <pub-id pub-id-type="doi">10.1016/j.egyr.2015.03.004</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Choi</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>G. R.</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>C. D.</given-names>
</name>
<name>
<surname>Cho</surname>
<given-names>S. H.</given-names>
</name>
<name>
<surname>Lim</surname>
<given-names>B. J.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Wind load on the solar panel array of a floating photovoltaic system under extreme hurricane conditions</article-title>. <source>Sustain. Energy Technol. Assessments</source> <volume>48</volume>, <fpage>101616</fpage>. <pub-id pub-id-type="doi">10.1016/j.seta.2021.101616</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Coakley</surname>
<given-names>J. A.</given-names>
</name>
</person-group> (<year>2003</year>). <article-title>Reflectance and albedo, surface</article-title>. <source>Encycl. Atmos. Sci.</source>, <fpage>1914</fpage>&#x2013;<lpage>1923</lpage>. <pub-id pub-id-type="doi">10.1016/b0-12-227090-8/00069-5</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Congedo</surname>
<given-names>P. M.</given-names>
</name>
<name>
<surname>Malvoni</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mele</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>De Giorgi</surname>
<given-names>M. G.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Performance measurements of monocrystalline silicon PV modules in South-eastern Italy</article-title>. <source>Energy Convers. Manag.</source> <volume>68</volume>, <fpage>1</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2012.12.017</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>da Costa</surname>
<given-names>L. C. A.</given-names>
</name>
<name>
<surname>da Silva</surname>
<given-names>G. D. P.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Save water and energy: a techno-economic analysis of a floating solar photovoltaic system to power a water integration project in the Brazilian semiarid</article-title>. <source>Int. J. Energy Res.</source> <volume>45</volume>, <fpage>17924</fpage>&#x2013;<lpage>17941</lpage>. <pub-id pub-id-type="doi">10.1002/er.6932</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dizier</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Techno-economic analysis of floating PV solar power plants using active cooling technique</article-title>. <source>A case study Taiwan</source>, <fpage>1</fpage>&#x2013;<lpage>68</lpage>.</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Elhadj Sidi</surname>
<given-names>C. E. B.</given-names>
</name>
<name>
<surname>Ndiaye</surname>
<given-names>M. L.</given-names>
</name>
<name>
<surname>El Bah</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mbodji</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ndiaye</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ndiaye</surname>
<given-names>P. A.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Performance analysis of the first large-scale (15 MWp) grid-connected photovoltaic plant in Mauritania</article-title>. <source>Energy Convers. Manag.</source> <volume>119</volume>, <fpage>411</fpage>&#x2013;<lpage>421</lpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2016.04.070</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>El Hammoumi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Chalh</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Allouhi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Motahhir</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>El Ghzizal</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Derouich</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Design and construction of a test bench to investigate the potential of floating PV systems</article-title>. <source>J. Clean. Prod.</source> <volume>278</volume>, <fpage>123917</fpage>. <pub-id pub-id-type="doi">10.1016/j.jclepro.2020.123917</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Exley</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Hernandez</surname>
<given-names>R. R.</given-names>
</name>
<name>
<surname>Page</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Chipps</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Gambro</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Hersey</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Scientific and stakeholder evidence-based assessment: ecosystem response to floating solar photovoltaics and implications for sustainability</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>152</volume>, <fpage>111639</fpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2021.111639</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goswami</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Effect of humidity on the generation capacity of floating solar photovoltaic system</article-title>. <source>Jordan J. Electr. Eng.</source> <volume>9</volume>, <fpage>31</fpage>&#x2013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.5455/jjee.204-1667584023</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goswami</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sadhu</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Goswami</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Sadhu</surname>
<given-names>P. K.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Floating solar power plant for sustainable development: a techno-economic analysis</article-title>. <source>Environ. Prog. Sustain Energy</source> <volume>38</volume>. <pub-id pub-id-type="doi">10.1002/ep.13268</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goswami</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sadhu</surname>
<given-names>P. K.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Degradation analysis and the impacts on feasibility study of floating solar photovoltaic systems</article-title>. <source>Sustain. Energy, Grids Netw.</source> <volume>26</volume>, <fpage>100425</fpage>. <pub-id pub-id-type="doi">10.1016/j.segan.2020.100425</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Goswami</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sadhu</surname>
<given-names>P. K.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Nature inspired evolutionary algorithm integrated performance assessment of floating solar photovoltaic module for low-carbon clean energy generation</article-title>. <source>Sustain. Operations Comput.</source> <volume>3</volume>, <fpage>67</fpage>&#x2013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1016/j.susoc.2021.10.002</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Gurfude</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Bhavitha</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Tanusha</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Mounika</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Gouda Kake</surname>
<given-names>S. P.</given-names>
</name>
<name>
<surname>Saisudha</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). &#x201c;<article-title>Techno-economic analysis of 1 MWp floating solar PV plant</article-title>,&#x201d; in <source>Proceedings of 2020 IEEE 1st international conference on smart technologies for power, energy and control, STPEC 2020</source>. <pub-id pub-id-type="doi">10.1109/STPEC49749.2020.9297740</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haas</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Khalighi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>de la Fuente</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gerbersdorf</surname>
<given-names>S. U.</given-names>
</name>
<name>
<surname>Nowak</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>P. J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Floating photovoltaic plants: ecological impacts versus hydropower operation flexibility</article-title>. <source>Energy Convers. Manag.</source> <volume>206</volume>, <fpage>112414</fpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2019.112414</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hafeez</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Kashif Janjua</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Nisar</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Shakir</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Shahzad</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Waqas</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Techno-economic perspective of a floating solar PV deployment over urban lakes: a case study of NUST lake Islamabad</article-title>. <source>Sol. Energy</source> <volume>231</volume>, <fpage>355</fpage>&#x2013;<lpage>364</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2021.11.071</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ibrik</surname>
<given-names>I. H.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Techno-economic assessment of on-grid solar PV system in Palestine</article-title>. <source>Cogent Eng.</source> <volume>7</volume>, <fpage>1727131</fpage>. <pub-id pub-id-type="doi">10.1080/23311916.2020.1727131</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jeong</surname>
<given-names>H. S.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>H. H.</given-names>
</name>
<name>
<surname>Jo</surname>
<given-names>H. S.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A study on the power generation prediction model considering environmental characteristics of floating photovoltaic system</article-title>. <source>Appl. Sci. Switz.</source> <volume>10</volume>, <fpage>4526</fpage>. <pub-id pub-id-type="doi">10.3390/app10134526</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Jiang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Qi</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Wei</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2020</year>) <source>Selection and peer-review under responsibility of the scientific committee of CUE2020 A techno-economic comparison between grounding PV and floating PV for shore power generation: case study of Yangshan port</source>.</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kjeldstad</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Lindholm</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Marstein</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Selj</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Cooling of floating photovoltaics and the importance of water temperature</article-title>. <source>Sol. Energy</source> <volume>218</volume>, <fpage>544</fpage>&#x2013;<lpage>551</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2021.03.022</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kowsar</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Hassan</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Rana</surname>
<given-names>M. T.</given-names>
</name>
<name>
<surname>Haque</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Faruque</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Ahsan</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Optimization and techno-economic assessment of 50 MW floating solar power plant on Hakaluki marsh land in Bangladesh</article-title>. <source>Renew. Energy</source> <volume>216</volume>, <fpage>119077</fpage>. <pub-id pub-id-type="doi">10.1016/j.renene.2023.119077</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Siu</surname>
<given-names>Y. L.</given-names>
</name>
<name>
<surname>Hubacek</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Energy-water nexus of wind power in China: the balancing act between CO 2 emissions and water consumption</article-title>. <source>Energy Policy</source> <volume>45</volume>, <fpage>440</fpage>&#x2013;<lpage>448</lpage>. <pub-id pub-id-type="doi">10.1016/j.enpol.2012.02.054</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lindholm</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Kjeldstad</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Selj</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Marstein</surname>
<given-names>E. S.</given-names>
</name>
<name>
<surname>Fj&#xe6;r</surname>
<given-names>H. G.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Heat loss coefficients computed for floating PV modules</article-title>. <source>Prog. Photovoltaics Res. Appl.</source> <volume>29</volume>, <fpage>1262</fpage>&#x2013;<lpage>1273</lpage>. <pub-id pub-id-type="doi">10.1002/pip.3451</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Wennersten</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Power generation efficiency and prospects of floating photovoltaic systems</article-title>. <source>Energy Procedia</source> <volume>105</volume>, <fpage>1136</fpage>&#x2013;<lpage>1142</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2017.03.483</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="web">
<collab>LONGi Solar LR6-60-HPB-300M solar panel</collab> (<year>2020</year>). <article-title>LONGi Solar LR6-60-HPB-300M solar panel</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://www.solarreviews.com/manufacturers/longi-solar/solar-panels/f46631b791himo3lr660hpb300m">https://www.solarreviews.com/manufacturers/longi-solar/solar-panels/f46631b791himo3lr660hpb300m</ext-link>.</comment>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ma</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Wan</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Dong</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Liang</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Multi-parameter practical stability region analysis of wind power system based on limit cycle amplitude tracing</article-title>. <source>IEEE Trans. Energy Convers.</source> <volume>38</volume> (<issue>4</issue>), <fpage>2571</fpage>&#x2013;<lpage>2583</lpage>. <pub-id pub-id-type="doi">10.1109/TEC.2023.3274775</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Martins</surname>
<given-names>B. P.</given-names>
</name>
</person-group> (<year>2019</year>) <source>Techno-economic evaluation of a floating PV system for a wastewater treatment facility</source>.</citation>
</ref>
<ref id="B40">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Miah</surname>
<given-names>M. A. R.</given-names>
</name>
<name>
<surname>Rahman</surname>
<given-names>S. R.</given-names>
</name>
<name>
<surname>Kabir</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2021</year>). &#x201c;<article-title>Techno-economic analysis of floating solar PV integrating with hydropower plant in Bangladesh</article-title>,&#x201d; in <source>IEEE green technologies conference 2021</source>, <fpage>30</fpage>&#x2013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1109/GreenTech48523.2021.00016</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Micheli</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Energy and economic assessment of floating photovoltaics in Spanish reservoirs: cost competitiveness and the role of temperature</article-title>. <source>Sol. Energy</source> <volume>227</volume>, <fpage>625</fpage>&#x2013;<lpage>634</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2021.08.058</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Micheli</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Talavera</surname>
<given-names>D. L.</given-names>
</name>
<name>
<surname>Marco Tina</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Almonacid</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Fern&#xe1;ndez</surname>
<given-names>E. F.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Techno-economic potential and perspectives of floating photovoltaics in Europe</article-title>. <source>Sol. Energy</source> <volume>243</volume>, <fpage>203</fpage>&#x2013;<lpage>214</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2022.07.042</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<collab>Ministry of Energy (Petroleum Division)</collab> (<year>2018</year>). <article-title>Hydrocarbon development institute of Pakistan. Pakistan energy year book 2018</article-title>. <source>Ministry Energy (Petroleum Div.)</source>.</citation>
</ref>
<ref id="B44">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Pasalic</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Aksamovic</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Avdakovic</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2018</year>). &#x201c;<article-title>Floating photovoltaic plants on artificial accumulations - example of Jablanica Lake</article-title>,&#x201d; in <source>2018 IEEE international energy conference, ENERGYCON 2018</source>, <fpage>1</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1109/ENERGYCON.2018.8398765</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pimentel Da Silva</surname>
<given-names>G. D.</given-names>
</name>
<name>
<surname>Branco</surname>
<given-names>D. A. C.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Is floating photovoltaic better than conventional photovoltaic? Assessing environmental impacts</article-title>. <source>Impact Assess. Proj. Apprais.</source> <volume>36</volume>, <fpage>390</fpage>&#x2013;<lpage>400</lpage>. <pub-id pub-id-type="doi">10.1080/14615517.2018.1477498</pub-id>
</citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Raza</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Khatri</surname>
<given-names>K. L.</given-names>
</name>
<name>
<surname>Israr</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ul Haque</surname>
<given-names>M. I.</given-names>
</name>
<name>
<surname>Ahmed</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Rafique</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Energy demand and production forecasting in Pakistan</article-title>. <source>Energy Strategy Rev.</source> <volume>39</volume>, <fpage>100788</fpage>. <pub-id pub-id-type="doi">10.1016/j.esr.2021.100788</pub-id>
</citation>
</ref>
<ref id="B47">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Rosa-Clot</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tina</surname>
<given-names>G. M.</given-names>
</name>
</person-group> (<year>2020</year>) <source>Geographic potential</source>. <publisher-name>Elsevier Inc</publisher-name>. <pub-id pub-id-type="doi">10.1016/B978-0-12-817061-8.00003-8</pub-id>
</citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rosa-Clot</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tina</surname>
<given-names>G. M.</given-names>
</name>
<name>
<surname>Nizetic</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Floating photovoltaic plants and wastewater basins: an Australian project</article-title>. <source>Energy Procedia</source> <volume>134</volume>, <fpage>664</fpage>&#x2013;<lpage>674</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2017.09.585</pub-id>
</citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Semeskandeh</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Hojjat</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Hosseini</surname>
<given-names>A. M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Techno-economic-environmental comparison of floating photovoltaic plant with conventional solar photovoltaic plant in northern Iran</article-title>. <source>Clean. Energy</source> <volume>6</volume>, <fpage>1118</fpage>&#x2013;<lpage>1126</lpage>. <pub-id pub-id-type="doi">10.1093/ce/zkac019</pub-id>
</citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sharma</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Goel</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Performance analysis of a 11.2 kWp roof top grid-connected PV system in Eastern India</article-title>. <source>Energy Rep.</source> <volume>3</volume>, <fpage>76</fpage>&#x2013;<lpage>84</lpage>. <pub-id pub-id-type="doi">10.1016/j.egyr.2017.05.001</pub-id>
</citation>
</ref>
<ref id="B51">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Siecker</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kusakana</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Numbi</surname>
<given-names>B. P.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>A review of solar photovoltaic systems cooling technologies</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>79</volume>, <fpage>192</fpage>&#x2013;<lpage>203</lpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2017.05.053</pub-id>
</citation>
</ref>
<ref id="B52">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Snehith</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Kulkarni</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2021a</year>). &#x201c;<article-title>Techno-economic analysis of proposed10 MWPFloating solar PV plant at nagarjuna sagar, telangana, India: Part-1</article-title>,&#x201d; in <source>ICCISc 2021 - 2021 international conference on communication, control and information sciences, proceedings</source>. (<publisher-loc>Kerala, India</publisher-loc>: <publisher-name>Institute of Electrical and Electronics Engineers Inc.</publisher-name>). <pub-id pub-id-type="doi">10.1109/ICCISc52257.2021.9484867</pub-id>
</citation>
</ref>
<ref id="B53">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Snehith</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Kulkarni</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2021b</year>). &#x201c;<article-title>Techno-economic analysis of proposed10 MWPFloating solar PV plant at nagarjuna sagar, telangana, India: Part-2</article-title>,&#x201d; in <source>ICCISc 2021 - 2021 international conference on communication, control and information sciences, proceedings</source>. (<publisher-loc>Kerala, India</publisher-loc>: <publisher-name>Institute of Electrical and Electronics Engineers Inc.</publisher-name>). <pub-id pub-id-type="doi">10.1109/ICCISc52257.2021.9484963</pub-id>
</citation>
</ref>
<ref id="B54">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Analysis of the potential for use of floating photovoltaic systems on mine pit lakes: case study at the Ssangyong open-pit limestone mine in Korea</article-title>. <source>Energies (Basel)</source> <volume>9</volume>, <fpage>102</fpage>&#x2013;<lpage>113</lpage>. <pub-id pub-id-type="doi">10.3390/en9020102</pub-id>
</citation>
</ref>
<ref id="B55">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Srivastava</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Tiwari</surname>
<given-names>A. N.</given-names>
</name>
<name>
<surname>Giri</surname>
<given-names>V. K.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>An overview on performance of PV plants commissioned at different places in the world</article-title>. <source>Energy Sustain. Dev.</source> <volume>54</volume>, <fpage>51</fpage>&#x2013;<lpage>59</lpage>. <pub-id pub-id-type="doi">10.1016/j.esd.2019.10.004</pub-id>
</citation>
</ref>
<ref id="B56">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Statistical Review</surname>
<given-names>B. P.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Stratistical review of world energy</article-title>. <source>Stat. Rev. World Energy</source> <volume>67</volume>, <fpage>1</fpage>&#x2013;<lpage>56</lpage>.</citation>
</ref>
<ref id="B57">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Temiz</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Dincer</surname>
<given-names>I.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Techno-economic analysis of green hydrogen ferries with a floating photovoltaic based marine fueling station</article-title>. <source>Energy Convers. Manag.</source> <volume>247</volume>, <fpage>114760</fpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2021.114760</pub-id>
</citation>
</ref>
<ref id="B58">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trapani</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Millar</surname>
<given-names>D. L.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Floating photovoltaic arrays to power the mining industry: a case study for the McFaulds lake (Ring of Fire)</article-title>. <source>Environ. Prog. Sustain Energy</source> <volume>35</volume>, <fpage>898</fpage>&#x2013;<lpage>905</lpage>. <pub-id pub-id-type="doi">10.1002/ep.12275</pub-id>
</citation>
</ref>
<ref id="B59">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trapani</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Red&#xf5;n Santaf&#xe9;</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>A review of floating photovoltaic installations: 2007-2013</article-title>. <source>Prog. Photovoltaics Res. Appl.</source> <volume>23</volume>, <fpage>524</fpage>&#x2013;<lpage>532</lpage>. <pub-id pub-id-type="doi">10.1002/pip.2466</pub-id>
</citation>
</ref>
<ref id="B60">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trillo-Montero</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Santiago</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Luna-Rodriguez</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Real-Calvo</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Development of a software application to evaluate the performance and energy losses of grid-connected photovoltaic systems</article-title>. <source>Energy Convers. Manag.</source> <volume>81</volume>, <fpage>144</fpage>&#x2013;<lpage>159</lpage>. <pub-id pub-id-type="doi">10.1016/j.enconman.2014.02.026</pub-id>
</citation>
</ref>
<ref id="B61">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Uddin</surname>
<given-names>M. N.</given-names>
</name>
<name>
<surname>Biswas</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Nuruddin</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Techno-economic impacts of floating PV power generation for remote coastal regions</article-title>. <source>Sustain. Energy Technol. Assessments</source> <volume>51</volume>, <fpage>101930</fpage>. <pub-id pub-id-type="doi">10.1016/j.seta.2021.101930</pub-id>
</citation>
</ref>
<ref id="B62">
<citation citation-type="book">
<collab>Where Sun Meets Water</collab> (<year>2019</year>) <source>Where Sun meets water</source>. <pub-id pub-id-type="doi">10.1596/32804</pub-id>
</citation>
</ref>
<ref id="B63">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Si</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Jia</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Whether rural rooftop photovoltaics can effectively fight the power consumption conflicts at the regional scale &#x2013; a case study of Jiangsu Province</article-title>. <source>Energy Build.</source> <volume>306</volume>, <fpage>113921</fpage>. <pub-id pub-id-type="doi">10.1016/j.enbuild.2024.113921</pub-id>
</citation>
</ref>
<ref id="B64">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yao</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Xiao</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Concentrated solar power plant modeling for power system studies</article-title>. <source>IEEE Trans. Power Syst.</source> <volume>39</volume> (<issue>2</issue>), <fpage>4252</fpage>&#x2013;<lpage>4263</lpage>. <pub-id pub-id-type="doi">10.1109/TPWRS.2023.3301996</pub-id>
</citation>
</ref>
<ref id="B65">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zahedi</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ranjbaran</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Gharehpetian</surname>
<given-names>G. B.</given-names>
</name>
<name>
<surname>Mohammadi</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Ahmadiahangar</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Cleaning of floating photovoltaic systems: a critical review on approaches from technical and economic perspectives</article-title>. <source>Energies (Basel)</source> <volume>14</volume>, <fpage>2018</fpage>. <pub-id pub-id-type="doi">10.3390/en14072018</pub-id>
</citation>
</ref>
</ref-list>
<app-group>
<app id="app1">
<title>Appendix A</title>
<table-wrap id="TA1" position="float">
<label>TABLE A1</label>
<caption>
<p>Results validation and comparative analysis of the proposed 2.5&#xa0;MW FPV project with an on-ground PV system of the same capacity.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameters</th>
<th align="left">Unit</th>
<th align="left">Fateh Jang (on-ground 2.5&#xa0;MW&#xa0;PV project)</th>
<th align="left">Sabakzai dam (proposed 2.5&#xa0;MW FPV project)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Capacity utilization factor</td>
<td align="left">(%)</td>
<td align="left">18.92</td>
<td align="left">22.00</td>
</tr>
<tr>
<td align="left">Final yield</td>
<td align="left">(kWh/kW/day)</td>
<td align="left">4.49</td>
<td align="left">5.28</td>
</tr>
<tr>
<td align="left">Performance ratio</td>
<td align="left">(%)</td>
<td align="left">79.2</td>
<td align="left">85.6</td>
</tr>
<tr>
<td align="left">Produced emission</td>
<td align="left">(tCO<sub>2</sub>)</td>
<td align="left">4464.45</td>
<td align="left">4532.56</td>
</tr>
<tr>
<td align="left">Replaced emission</td>
<td align="left">(tCO<sub>2</sub>)</td>
<td align="left">46361.9</td>
<td align="left">53,626</td>
</tr>
<tr>
<td align="left">Emission balance</td>
<td align="left">(tCO<sub>2</sub>)</td>
<td align="left">36,738</td>
<td align="left">43125.7</td>
</tr>
<tr>
<td align="left">System production</td>
<td align="left">(MWh/year)</td>
<td align="left">4167</td>
<td align="left">4820</td>
</tr>
<tr>
<td align="left">Specific production</td>
<td align="left">(kWh/kW<sub>p</sub>/year)</td>
<td align="left">1,668</td>
<td align="left">1927</td>
</tr>
<tr>
<td align="left">Normalized production</td>
<td align="left">(kWh/kW<sub>p</sub>/day)</td>
<td align="left">4.57</td>
<td align="left">5.28</td>
</tr>
<tr>
<td align="left">Array losses</td>
<td align="left">(kWh/kW<sub>p</sub>/day)</td>
<td align="left">0.90</td>
<td align="left">0.66</td>
</tr>
<tr>
<td align="left">System losses</td>
<td align="left">(kWh/kW<sub>p</sub>/day)</td>
<td align="left">0.21</td>
<td align="left">0.23</td>
</tr>
<tr>
<td align="left">Pay-back period</td>
<td align="left">(years)</td>
<td align="left">3.4</td>
<td align="left">6.0</td>
</tr>
<tr>
<td align="left">The total cost of the project</td>
<td align="left">($)</td>
<td align="left">1,252,190</td>
<td align="left">1782278.16</td>
</tr>
</tbody>
</table>
</table-wrap>
</app>
</app-group>
</back>