Abstract

The increasing wastewater pollution and its potential harmful impacts make it imperative to seek cost-effective and sustainable solutions for wastewater treatment while exploring options for resource recovery from waste. A two-stage biological treatment system was evaluated: (i) aerobic bacteria) Pseudomonas fluorescens (used to remove pollutants from real municipal wastewater and (ii) the cyanobacteria Oscillatoria splendida used to polish the effluent. The wastewater was obtained from the Greater Ramadi Sewerage Project, Iraq, utilizing three independent composite samples (20 L each) collected from the raw wastewater inlet and characterized for pH, EC, TDS, TSS, nutrients, heavy metals, and total bacterial count. The samples were treated under controlled laboratory conditions at the University of Anbar. Stage 1 involved the exposure of wastewater for 6 h to P. fluorescens 1.5 × 108) CFU/mL) in a serial glass-filter bioreactor containing activated carbon and polyethylene media. For Stage 2, the Stage-1 effluent was diluted to 20%, 40%, and 60% (v/v (using sterilized distilled water, and fed to O. splendida for 15 days (2,500 lux illumination, 16:8 h light/dark) with sampling on Days 0, 5, 10, and 15. In Stage 1, descriptive reductions were observed in COD (81.4%), TDS (62.6%), Ni (75.1%), and Zn (71.7%) across the three independent wastewater samples; however, due to the limited sample size (n = 3 independent composite batches), a paired t-test confirmed statistical significance only for Co2+ (p = 0.026). Two-way ANOVA performed on the triplicate experimental data (sub-samples within each batch) from Stage 2 revealed that both the dilution ratio and the incubation day significantly affected all measured parameters (p < 0.05) The greatest decreases occurred at) 20%v/v (dilution for most parameters (EC 56.6%, TDS 99.5%, BOD5 32.3%, Ni 64.9%, Co. 88.3%) and at) 40% v/v (dilution for phosphate (55.5%) and copper (84.5% (The sequential two-stage system yielded higher cumulative removal efficiencies than the P. fluorescens stage alone) e.g., cumulative COD removal ≈ 93% versus 81.4% for Stage 1 alone). This sequential performance suggests a beneficial treatment sequence, though parallel single-treatment) O. splendida-only) controls were not run under identical conditions to statistically define a synergistic effect. The outcomes indicate that this two-stage biological scheme holds potential as a polishing step for municipal wastewater in resource-limited arid areas like Iraq, providing a preliminary rationale for future circular-bioeconomy and biomass-recovery assessments at a pilot scale.

1 Introduction

Wastewater treatment and a method to harness resources from the waste. Most wastewater (UNEP, 2021) is sent into water bodies without sufficient treatment, resulting in the loss of biodiversity, the spread of waterborne diseases and the degradation of freshwater ecosystems globally, with over 80% of wastewater not being treated. Rapid urbanisation, industrialisation and lack of investment in infrastructure, compounded in the developing world and water scarce regions. In the Tigris–Euphrates River basin, where water security of millions of people is affected, increasing urban pollution and industrial waste from Tigris–Euphrates valley is an issue of particular concern, and thus the need for effective and advanced biological treatment technologies in the valley is required in a cost effective manner in Tigris–Euphrates river basin (Al-Obaidi et al., 2022).

For over 100 years, conventional wastewater treatment plants (WWTPs) have been the infrastructure used for the treatment of domestic wastewater for a century or more, through physical sedimentation, chemical coagulation-flocculation, and activated sludge processes. These are, however, systems with definite drawbacks such as high capital costs, high energy consumption, large amounts of secondary sludge for safe disposal, and limited effectiveness for removing emerging micropollutants, dissolved nutrients and trace amounts of heavy metals, etc. (Wang et al., 2021). Activated sludge processes have proven to be efficient at removing organic matter but less efficient in providing consistent removal of nitrogen and phosphorous, unless a chemical dose is added to the system which raises operating costs and environmental problems (Meng et al., 2020). There is thus a growing need for bio-solutions that are more energy efficient, eco-friendly and able to remove several classes of contaminants at a time.

Pseudomonas fluorescens has been the subject of continuous research interests among the candidate bacteria, due to its metabolic versatility. This Gram-negative, aerobic bacterium is able to degrade a broad spectrum of organic substrates as carbon and energy sources, produces well characterised biofilms that enhance its retention and effectiveness in bioreactor systems, and possesses high emulsifying activity of biosurfactants (Scales et al., 2014; Shahid et al., 2021). This bacterium P. fluorescens can be used as a practical agent for aerobic pre-treatment as it is effective with phenolic compounds, petroleum hydrocarbon, N-based pollutant and also it has a strong biosorptive and biotransformation capacity towards heavy metals (Singh et al., 2020).

Cyanobacteria, often called blue-green algae, are an ancient and metabolically diverse group of prokaryotes. Oscillatoria spp. Commonly colonise nutrient-rich freshwater and transitional habitats with variable light and dark cycles (Mohapatra et al., 2023). The filamentous cyanobacterium Oscillatoria splendida assimilates inorganic nitrogen and phosphorus into its own biomass, removing nutrients that would otherwise drive eutrophication in secondary effluents (García-Galán et al., 2021), while functional groups and polysaccharides on its cell wall bind and remove trace heavy metals such as Zn, Cu, Ni and Co. through biosorption (Rajneesh et al., 2017; Cheng et al., 2020).

Integrated bacteria–algae systems have gained popularity over the last decade as a metabolic partnership in which heterotrophs break down contaminants and phototrophs capture and convert the products into biomass: The CO2 and N2 by-products produced by the bacteria enable cyanobacterial photosynthesis and the oxygen produced by cyanobacterial photosynthesis enables aerobic bacteria activity (Aditya et al., 2022). Such systems have been reported to remove organic matter, nutrients and heavy metals more effectively than single-organism treatments (Renuka et al., 2021; de Godos et al., 2020).

Notwithstanding this advancement, there are three aspects for which these findings are not transferrable to real treatment situations. First, most systems that have been published for treating bacteria–cyanobacteria mixtures have been evaluated at low (synthetic or highly diluted) wastewater concentrations under idealised laboratory conditions, and little is known about how these systems will perform at the more complex and variable concentrations found in most municipal wastewater. Second, the effect of the bacterially pre-treated effluent dilution ratio on subsequent $O$. Splendida performance is not systematically quantified being relevant as it is possible that a residual ammonia and/or dissolved organic matter can be inhibitory for the cyanobacteria. Third, relevant data in the field are virtually unavailable in the Middle East, where preservation and reuse of water is a lifeline in dry and semi-dry areas like the Euphrates basin. The present study directly tackles the above three drawbacks by employing the two-stage system on real municipal wastewater effluents from Greater Ramadi Sewerage Project (GRSP) in Iraq and by systematically changing the dilution ratio of the cyanobacterial polishing.

The main objective of the present study was to design and evaluate a two-stage biological treatment system (BTS) for treatment of real municipal wastewater (RMWW) from GRSP. Stage 1 involved the use of P. fluorescens in a laboratory-scale, aerated biofilter containing activated carbon and polyethylene media. For 15 days, O. splendida was used as a polishing treatment to the stage 1 effluent at three different dilution rates (20%, 40% and 60%). The hypotheses (1) that P. fluorescens pre-treatment would significantly reduce the organic loading and the heavy-metal content and consequently make the substrate more favourable for the growth of O. splendida, (2) that assimilation and biosorption by O. splendida would remove the remaining nutrients and metals from the substrate, and (3) that an intermediate dilution would maximize removal efficiency because the remaining components of the wastewater would have minimal inhibitory effect on the metabolism of O. splendida, were tested. The results provide a direct contribution to the body of evidence of integrated microbial treatment system in resource limited municipal wastewater treatment plant conditions.

2 Materials and methods

2.1 Study area and sample collection

This study was carried out at the Centre for the Research and Development of the Upper Euphrates Basin, University of Anbar, Iraq, from October 2025 to May 2026. Wastewater was sampled from the raw inlet of the Greater Ramadi Sewerage Project (GRSP), located in the Tourist City area of Ramadi Island adjacent to the Euphrates River. The facility has a design capacity of 100,000 m3/day and, via 12 secondary pumping stations, serves approximately 500,000 inhabitants; an estimated 17% of the city’s residents are currently connected to the municipal sewerage network.

Samples were collected in sterile 20 L polyethylene containers, with three replicate containers pooled for each of three independent sampling events across the study period. All samples were transported to the laboratory within 1 hour of collection. Physicochemical parameters were analysed immediately on receipt, while sub-samples for microbiological isolation were transferred aseptically to sterilised glass bottles.

2.2 Physicochemical and microbiological analyses

The following parameters were measured: pH (measured by Hanna pH meter), electrical conductivity (EC measured by WTW/HANNA conductivity meter, Germany), total dissolved solids (TDS), total suspended solids (TSS), total phosphate (TPO43-), and sulphate (SO42-) by spectrophotometric method at 420 nm, nitrite (NO2−) and nitrate (NO3−) by spectrophotometric method at 540 nm, and total nitrogen (TN) by spectrophotometric method at 410 nm. Using an HI83200 multiparameter photometer; 5-day biochemical oxygen demand (BOD5); and chemical oxygen demand (COD, Lovibond MD200/COD VARIO). Heavy metal concentrations (Zn2+, Cu2+, Ni2+ and Co2+) were measured by atomic absorption spectroscopy (AAS). Total bacterial count (TBC) was determined by the standard plate count method on nutrient agar (American Public Health Association, 2017).

2.3 Isolation and identification of pseudomonas fluorescens

Wastewater samples were inoculated onto King’s B agar and incubated for 36 h, then sub-cultured onto a Pseudomonas-selective agar at 37 °C for 48 h to isolate presumptive colonies. Isolates were screened by Gram staining, oxidase and catalase reactions, and fluorescent pigment production under UV light, all of which were consistent with Pseudomonas spp. Species-level identification was confirmed using the Vitek 2 automated identification system (bioMérieux), which returned P. fluorescens with > 96% confidence (“excellent identification”) based on a 64-substrate Gram-negative biochemical card; the full biochemical reaction profile is provided in the Supplementary Material. Growth was additionally tested at 4 °C and 42 °C following Holt et al. (2004): the isolate grew at 4 °C but not at 42 °C, consistent with published characteristics of P. fluorescens.

2.4 Stage 1: aerobic treatment using pseudomonas fluorescens

The small-scale (laboratory) bioreactor used was of series in three glass separating funnels (each 1 L, 19 cm diameter, 26 cm long) that were packed together as a multi-layer filter to simulate a secondary-treatment environment. A layer of activated carbon of size 6 cm (height) in funnel 1, 6 cm in funnel 2 and 3, content of 8 cm of large polyethylene beads and 3.5 cm of small polyethylene beads respectively. Adsorption capacity of the activated carbon and P. fluorescens biofilm formation were both on the surface presented by the carbon material.

A pure culture of nutrient agar was transferred to 5 mL sterile nutrient broth and grown at 37 °C for 4–5 h and 1 mL of the nutrient broth was again transferred to 9 mL sterile nutrient broth and grown again for 6 h at 37 °C. The resultant suspension was sterile saline-adjusted to McFarland standard 0.5 (about 1.5 aqueously 10 o CFU/mL). Wastewater Pre-settling was done by allowing the wastewater to settle (1 h1.5 h) and pre-autoclaving (121 age, 15 psi, 15 min) prior to inoculation with the standardised P. fluorescens suspension and continuously aerated (6 hambient temperature 25). Every treatment cycle treated an average of 500 mL of wastewater with an average hydraulic retention time of about 10 min to produce about 470 mL of treated effluent.

2.5 Stage 2: cyanobacterial polishing using oscillatoria splendida

Oscillatoria splendida was isolated from the banks of the Euphrates River and identified using the taxonomic keys of Desikachary (1959) and Willey et al. (2011). The culture was maintained in BG11 medium (Stanier et al., 1971) and progressively acclimatised to wastewater over 14-day intervals by repeated transfer between BG11 and sterilised wastewater (Table 1). Working cultures were maintained in 2,500 mL flasks on a shaker incubator at 25 °C ± 2 °C under 260 µmol photons m-2 s-1 illumination.

TABLE 1

ParameterUnitInitial (avg)After P. fluorescens (avg)Removal %
pH—8.477.72—
ECµS/cm2,533171632.2%
TDSmg/L56721262.6%
TSSmg/L266.7168.736.7%
TPO43-mg/L101.344.855.8%
SO42-mg/L164.0133.018.9%
NO3-mg/L4.1072.32943.3%
NO2-mg/L54.5527.8349.1%
BOD5mg/L366.7232.036.8%
CODmg/L1,378.7257.081.4%
Zn2+ppm2.1800.61671.7%
Cu2+ppm0.7930.50436.4%
Ni2+ppm0.7200.17975.1%
Co2+mg/L0.9150.36759.9%

Pollutant removal by Pseudomonas fluorescens in stage 1 treatment.

Stage-1 effluent was diluted with sterilised distilled water to give three treatment levels — 20%, 40% and 60% — and 500 mL of each dilution was autoclaved and inoculated with 100 mL of O. splendida biomass harvested from the exponential growth phase. Samples were incubated under 2,500 lux illumination (16:8 h light/dark photoperiod) at 25 °C, and full physicochemical analysis was performed on Days 5, 10 and 15. All treatments were run in triplicate.

2.6 Statistical analysis

All reported values are means of triplicate measurements. Pollutant removal efficiency (RE%) was calculated as:

For Stage 1, mean pollutant concentrations before and after P. fluorescens treatment (n = 3 independent wastewater samples) were compared using a paired-samples t-test. For Stage 2, the effect of dilution (20%, 40%, 60%) and incubation day (5, 10, 15) on each pollutant concentration was tested using two-way analysis of variance (ANOVA) on the triplicate measurements at each dilution × day combination, followed by Tukey’s honestly significant difference (HSD) post hoc test for pairwise comparisons among dilutions and among days. All tests used α = 0.05 and were performed in Python (SciPy 1. x/ statsmodels 0.14). Analyses were run using the raw triplicate data underlying Tables 2–6 (author-supplied laboratory records).

TABLE 2

ParameterUnitSample 1Sample 2Sample 3Mean ± SD
pH—8.48.58.58.47 ± 0.06
ECµS/cm2,3902,6702,5402,533 ± 140
TDSmg/L700400600567 ± 152
TSSmg/L100300400267 ± 153
TPO43-mg/L10012084101.3 ± 18.0
SO42-mg/L92200200164 ± 62.5
NO3-mg/L3.333.335.664.11 ± 1.35
NO2-mg/L72.7933.4057.4754.6 ± 20.0
BOD5mg/L300400400367 ± 57.7
CODmg/L2,5205801,0361,379 ± 1,005
TBCCFU/mL6 × 1063.9 × 1066.3 × 1065.4 × 106
Zn2+ppm3.0641.0212.4552.18 ± 1.04
Cu2+ppm0.7291.0960.5550.793 ± 0.27
Ni2+ppm0.5901.3000.2710.720 ± 0.52
Co2+mg/L0.7140.9201.1100.915 ± 0.20

Physicochemical and microbiological characteristics of raw wastewater (n = 3).

TABLE 3

ParameterMean beforeMean aftertp-valueSignificant (p < 0.05)?
pH8.4677.7233.0550.093No
EC (µS/cm)2,533.31716.32.5580.125No
TSS (mg/L)266.7168.70.9610.438No
TPO43- (mg/L)101.344.83.5480.071No
SO42- (mg/L)164.0133.00.7490.532No
NO3− (mg/L)4.1072.3293.9850.058No
NO2− (mg/L)54.5527.832.2450.154No
BOD5 (mg/L)366.7232.01.6790.235No
COD (mg/L)1,378.7257.01.8470.206No
Zn2+ (ppm)2.1800.6162.2780.150No
Cu2+ (ppm)0.7930.5042.1620.163No
Ni2+ (ppm)0.7200.1791.8220.210No
Co2+ (mg/L)0.9150.3676.0900.026Yes

Paired-Samples t-Test: Stage-1 Pollutant Concentrations Before vs. After Treatment (n = 3).

TABLE 4

ParameterDilution effect (p)Day effect (p)Dilution × day interaction (p)
EC<0.0001<0.00010.0001
TDS<0.0001<0.0001<0.0001
TPO43-<0.0001<0.00010.752 (ns)
SO42-<0.0001<0.00010.549 (ns)
NO2-<0.0001<0.00010.009
NO3-<0.0001<0.0001<0.0001
BOD5<0.0001<0.00010.742 (ns)
COD<0.0001<0.0001<0.0001
Zn2+0.016<0.0001<0.0001
Cu2+<0.0001<0.00010.016
Ni2+<0.0001<0.00010.0006
Co2+0.005<0.00010.156 (ns)

Two-Way ANOVA Summary—Effect of Dilution and Incubation Day on Stage-2 Pollutant Concentrations (Days 5, 10, 15; n = 3 per cell).

TABLE 5

ParameterDilutionDay 0Day 5 (mean)Day 10 (mean)Day 15 (mean)Overall removal %
EC (µS/cm)20%360264.7255.0156.356.6%
40%760519.0354.7277.363.5%
60%966860.3642.3397.058.9%
TDS (mg/L)20%1581.070.970.8499.5%
40%1931.611.421.0899.4%
60%2461.971.531.3099.5%
TPO4(mg/L)20%237184.0135.0126.346.7%
40%290192.3145.3129.055.5%
60%349283.0224.0238.031.8%

EC, TDS and TPO43- reduction by Oscillatoria splendida at three dilutions over 15 Days.

TABLE 6

ParameterDilutionDay 0Day 5Day 10Day 15Removal %
BOD5(mg/L)20%10088.076.067.732.3%
40%137122.3112.094.730.9%
60%208188.3176.7165.320.5%
COD (mg/L)20%11796.767.762.346.7%
40%196159.3129.397.350.4%
60%206188.3161.392.055.3%
SO42-(mg/L)20%5542.335.329.746.0%
40%7560.045.039.347.6%
60%9075.763.758.035.6%
NO3- (mg/L)20%2.0111.6181.4401.25737.5%
40%2.1251.7851.5911.41533.4%
60%2.1651.9071.7351.65823.4%
NO2- (mg/L)20%15.3914.3313.1812.1321.2%
40%20.1818.7114.9513.1334.9%
60%23.1022.0418.2315.1934.2%

BOD5, COD, SO42-, NO3− and NO2− removal by Oscillatoria splendida over 15 Days.

3 Results and discussion

3.1 Initial wastewater characteristics

Physicochemical characterisation of the three independent raw wastewater samples showed properties typical of municipal wastewater in the region (Table 2). The mean pH (8.47 ± 0.06) was alkaline, consistent with the limestone geology of the catchment and with biochemical decomposition processes that release hydroxyl ions. Electrical conductivity (2,533 ± 140 μS/cm) and TDS (567 ± 152 mg/L) indicated moderate dissolved-salt loading, while TSS (267 ± 153 mg/L) was consistent with unfractionated domestic and light-industrial effluent containing particulate organic material.

There was a high level of organic loading with an average of 367 ± 57.7 mg/L (range of 580 to 2,520) of BOD5 and 1,379 ± 1,005 mg/L (range of 580 to 2,520) of COD per sample. BOD5:COD ratio is approximately 0.27, suggesting that there is a mix of biodegradable and more recalcitrant organic compounds. The mean TPO43- was 101.3 mg/L, indicating a high nutrient load, while the mean concentrations of NO3− (4.11 mg/L) and NO2− (54.6 mg/L) suggested that there was some active nitrification-denitrification within the collection system. Total bacterial counts ranged from 3.9 × 106 to 6.3 × 106 CFU/mL, which was similar to the bacterial counts found in raw municipal wastewater. Most water quality concentrations, such as Zn2+ 2.18 ppm, Cu2+ 0.793 ppm, Ni2+ 0.720 ppm, Co2+ 0.915 mg/L, were lower than the acute toxicity concentrations for most aquatic life but higher than the recommended concentrations for reuse in agricultural soils.

3.2 Stage 1: performance and mechanisms of pseudomonas fluorescens

All measured physicochemical parameters have improved after 6 h of aerobic biofilter treatment (Table 1). The maximum decrease was observed in COD which is mainly attributed to efficient and complete aerobic oxidation of labile organic compounds by a broad spectrum of oxygenase enzymes present in P. fluorescens, which seem to be facilitated by continuous aeration for 6 h, probably through the aerobic breakdown of organic matter to CO2 and H2O through the flavoprotein oxygenase and cytochrome dependent oxygenase respiratory chain (Shahid et al., 2021). This COD removal (81.4%) is better than Singh et al. (2020) 72%–78% using P. fluorescens for synthetic wastewater in batch reactors, indicating good performance of this strain in handling more complex real municipal wastewater. Dissolved organic solids are removed by the microbial assimilation combined with adsorption onto the activated-carbon support, which may be more effective than removing dissolved organic solids from a planktonic bacterial suspension as the biofilm architecture on activated carbon and polyethylene media has been reported to enhance the adsorbing-biodegradation process of P. fluorescens (Wang et al., 2021). Metal cations ions become more available for biosorption in subsequent treatment stages as mean pH in the treatment water during Stage 1 decreased from 8.47 to 7.72, which is typical for the production of organic acid/CO2 during aerobic respiration.

The pH reduced in Stage 1–7.72, which is in line with the production of organic acids and CO 2 in the aerobic respiration; a shift to a neutral pH also enhances the number of metal cations that could be available to the biosorption process in the subsequent treatment stages. It should be noted that substantial heavy-metal removal of Ni 2 + (75.1-71.7-59.9) was observed, which is similar to what happens with biosorption by the negatively charged cell envelope of P. fluorescens (zeta potential −20 to −35 mv) and by carboxylate, phosphoryl and sulfhydryl groups in their extracellular polymeric substances (Shahid et al., 2021). The removal of Cu2+ was relatively reduced (36.4%), which is likely due to the formation of stable organometallic complexes of Cu2+ and water soluble humic substances in wastewater and therefore, less free Cu2+ was available to be removed in the biosorption process. The transformation of nitrogen was apparent by the decrease in NO3 - (43.3%), NO2 - (49.1%), in line with the net assimilation of nitrates and the potential of some micro-scale denitrification processes in the biofilm. The removal of BOD 5 (36.8%), TSS (36.70) was slightly smaller as well, which is more in line with the short (6 h) operating hydraulic retention time. Stage-1 effluent, which contained significantly lowered organic and metal loads, was fed on as the substrate in Stage 2 cyanobacterial polishing.

3.3 Stage 2: performance and mechanisms of oscillatoria splendida

3.3.1 Electrical conductivity, TDS and phosphate

There were significant decreases in EC, TDS and TPO around the 15-day incubation period in all three dilutions (Table 3; Figure 1). The highest percent EC decrease (56.6%; 360 to 156.3 μS/cm) was in the 20% dilution, the highest absolute EC decrease (760–277.3 μS/cm), but still with a reduction of 58.9% was in the 60% dilution. At all three dilutions, TDS reductions were greater than 99% indicating that dissolved organic and inorganic solids can be effectively assimilated by cyanobacteria when initial TDS load (158,246 mg/L, already lower after dilution) is present. TPO43- declined from 237, 290 and 349 mg/L (Day 0, at 20%, 40% and 60% respectively) to 126.3, 129.0 and 238.0 mg/L by Day 15 — removal efficiencies of 46.7%, 55.5% and 31.8%. This is because, unlike most other parameters, phosphate removal was maximised at 40 per cent dilution (the optimum medium in most other parameters being 20 per cent dilution); a consistent pattern indicates luxury phosphorus uptake by O. splendida occurs best at an intermediate nutrient concentration not too dilute to induce uptake but not so concentrated as to induce osmotic or substrate stress (refer to Figure 3.3.2).

FIGURE 1

Despite the large percentage reductions reported for Stage 1 (Section 3.2), a paired t-test on the three independent wastewater samples found only the reduction in Co2+ to be statistically significant (p = 0.026). All other parameters showed p-values between 0.06 and 0.53 — that is, consistent reductions in the same direction across all three samples, but not statistically significant at α = 0.05. This reflects the limited statistical power of an n = 3 paired design rather than an absence of a real treatment effect: with only three independent wastewater samples, even a genuine, consistent ∼60–80% reduction can fail to reach conventional significance thresholds. NO3− (p = 0.058) and TPO43- (p = 0.071) were the closest to significance. This is an important caveat for interpreting Stage-1 results and reinforces Reviewer 3’s point that firmer statistical conclusions will require a larger number of independent wastewater samples in future work (Section 4.2).

For every parameter, both dilution and incubation day had a statistically significant effect on pollutant concentration (p < 0.05, and p < 0.0001 for most parameters), confirming that the differences reported across dilutions (Section 3.3.1–3.3.3) and over time are not attributable to random variation. A significant dilution × day interaction (roughly half the parameters, notably EC, TDS, NO2−, COD, Zn2+, Ni2+) indicates that the effect of dilution was not constant across the incubation period—consistent with the differential removal patterns described below, where the best-performing dilution sometimes differed between the organic/nitrogen group (best at 20%) and the phosphate/sulphate/copper group (best at 40%). Tukey HSD pairwise comparisons (Supplementary Statistical Tables) confirm that Day 15 differed significantly from Day 5 for nearly every parameter (p < 0.05), supporting the description of progressive removal over the incubation period, while the 20% vs. 60% and 40% vs. 60% dilution comparisons were significant for most parameters, consistent with poorer performance at the highest (60%) dilution.

3.3.2 Organic load and macronutrient removal (BOD5, COD, SO42-, NO3− and NO2−)

BOD5 and COD declined consistently at every dilution and time point (Table 4; Figures 2, 3). BOD5 fell by 32.3% at 20% dilution (100–67.7 mg/L), and by 30.9% and 20.5% at 40% and 60%, respectively; the lower removal at 60% dilution is consistent with substrate/inhibition stress on O. splendida metabolism at higher residual wastewater concentrations. COD removal followed a different pattern — 46.7% at 20% (117–62.3 mg/L), 50.4% at 40% (196–97.3 mg/L) and 55.3% at 60% (206–92.0 mg/L) — with the higher percentage removal at 60% likely reflecting a larger residual organic-carbon pool available to a mixotrophic/heterotrophic component of growth alongside photosynthesis.

FIGURE 2

FIGURE 3

Sulphate removal ranged from 35.6% to 47.6%, with 40% dilution most effective. NO3− removal was highest at 20% (37.5%), followed by 40% (33.4%) and 60% (23.4%); NO2− removal ranged from 21.2% to 34.9%, again favouring the 40% dilution. Taken together, most organic and nitrogen parameters were removed most effectively at 20% dilution, while phosphate, sulphate and NO2− favoured 40% dilution—an intermediate-dilution effect consistent with a nutrient-dependent optimum for specific uptake pathways rather than a single universally optimal dilution (see Section 3.4 for how this is reconciled across parameters).

3.3.3 Heavy metal removal and biosorption mechanisms

Concentrations of all four heavy metals declined progressively over the 15-day treatment period, with the magnitude depending on metal identity, dilution and time (Table 5; Figure 4). Co2+ showed the highest overall removal at every dilution (88.3% at 20%, 84.8% at 40%, 87.4% at 60%; e.g., 0.230 to 0.027 mg/L at 20%), with the similarity of removal across dilutions suggesting a dedicated, high-affinity uptake pathway rather than simple concentration-dependent passive adsorption—consistent with cobalt-specific transport systems that cyanobacteria retain for cobalamin (vitamin B12) biosynthesis (Rajneesh et al., 2017) (Table 7). Cu2+ removal was highest at 40% dilution (84.5%; 0.373 to 0.058 ppm), plausibly because the higher biomass-supporting nutrient level at 40% increased the number of available biosorption sites, while Ni2+ and Zn2+ removal (64.9%–73.3% and 37.8%–86.9%, respectively) generally increased with initial metal concentration, consistent with adsorption-equilibrium behaviour within the non-inhibitory concentration range. Across all four metals, the fastest removal occurred between Days 0–5, consistent with an initial phase of rapid, passive, surface biosorption followed by a slower phase (Days 5–15) of active intracellular bioaccumulation (Cheng et al., 2020).

FIGURE 4

TABLE 7

MetalDilutionDay 0Day 5Day 10Day 15Removal %
Zn2+ (ppm)20%0.2410.2100.1830.15037.8%
40%0.3070.2830.1030.06778.2%
60%0.4450.3420.0930.05886.9%
Cu2+ (ppm)20%0.2280.1870.1260.08960.9%
40%0.3730.1920.1110.05884.5%
60%0.4120.3270.2200.11272.8%
Ni2+ (ppm)20%0.2390.2000.1870.08464.9%
40%0.3000.2500.1840.08073.3%
60%0.3400.2960.2300.09771.5%
Co2+. (mg/L)20%0.2300.1500.0830.02788.3%
40%0.3100.2470.1030.04784.8%
60%0.3400.2430.1230.04387.4%

Heavy metal removal by Oscillatoria splendida at three dilutions over 15 Days.

3.4 Combined system performance and comparison with previous studies

Comparing Stage 1 alone with the full two-stage system at 20% (v/v) dilution/Day 15 (Figure 5), the combined system achieved higher cumulative removal than Stage 1 alone for every parameter examined—for example, ∼93% cumulative COD removal versus 81.4% for Stage 1 alone, >90% cumulative Ni2+ removal, and ∼95% cumulative Co2+ removal. This pattern is consistent with the hypothesis that bacterial pre-treatment lowers organic and metal loading to a level more favourable for O. splendida growth and uptake. However, because this study did not include an O. splendida*-only treatment on raw (non-pre-treated) wastewater under otherwise identical conditions, the improvement cannot be formally attributed to synergy in a statistical sense; it is best described as evidence consistent with a beneficial interaction between the two stages, which single-treatment control experiments and formal statistical comparison (see Section 2.6) would be needed to confirm.

FIGURE 5

The two-stage system’s overall COD removal (∼93% at 20% (v/v) dilution, Day 15) is comparable to the 95% reported by de Godos et al. (2020) for a continuous-flow bacteria–microalgae system treating swine slurry, though that feed was simpler and more readily biodegradable than real municipal wastewater. Nutrient removal in the present study is broadly consistent with, though somewhat lower than, the 70%–85% (N) and 60%–75% (P) reported by García-Galán et al. (2021) for Oscillatoria spp. In secondary effluents; here the remaining removal can be reasonably explained by a reduced ratio of algal to wastewater inoculums, and by a reduced length of treatment and may well be reduced by a higher density of inoculum or longer length of treatment (Section 4.2). The removal of heavy-metals (up to 88.3% Co2+, 84.5% Cu2+, 73.3% Ni2+, 86.9% Zn2+) was greater than that achieved by Mohapatra et al. (2023) with similar cyanobacterial systems and was much better than the 20%–50% commonly used in conventional activated sludge These findings supports the potential value of cyanobacterial-polishing of effluent to be used on agricultural lands, although this efficiency remains to be confirmed under field conditions before being treated as fully established.

4 Practical implications

The two-stage P. fluorescens–O. splendida system could be a potential tertiary treatment process at MWWPs in resource-limited locations, owing to its use of naturally occurring microorganisms and the absence of introducing exotic nutrient substrate; and the use of bacteria treated water as nutrient substrate for the cyanobacterium O. splendida would be broadly in line with the concepts of circular-bioeconomy (Aditya et al., 2022) but it still needs to be proven at a pilot scale instead of solely in the laboratory. A biological polishing stage after the primary treatment could potentially lessen the nutrients and metals entering the Euphrates River, reducing the risk of eutrophication and metal bioaccumulation downstream, as published cost estimates of tertiary treatment using PVs are 40%–60% lower than the cost for conventional tertiary treatment (Wang et al., 2021), a cost savings that needs to be confirmed for this particular system and site before it can be presented as the cost of tertiary treatment using PVs. The potential for a biofertiliser or supplementary aquaculture feed that would enhance the profits of the operation and provide a vital contribution to a circular water–nutrient economy for agricultural regions that rely heavily on the Euphrates region is an interesting development that continues to be explored but not proven through the present study; the remaining O. splendida biomass, containing 40%–60% protein (DW) along with polyunsaturated fatty acids and other bioactive compounds, is an interesting development to pursue and not yet demonstrated by the present study.

4.1 Limitations

Several limitations should be considered when interpreting these results.

  • Laboratory-scale, controlled conditions may not replicate the variability of full-scale treatment, particularly seasonal changes in solar irradiance, temperature and wastewater composition in the Ramadi region.

  • The study did not include single-treatment controls (O. splendida alone on raw wastewater, or carrier-only controls without bacterial inoculation), so the relative contributions of carrier adsorption, P. fluorescens biodegradation, and any true synergistic interaction between the two stages cannot be separated with the present design; the improved performance of the combined system (Section 3.4) should be read as evidence consistent with, but not proof of, synergy.

  • Species-level identification of the bacterial isolate currently rests on Vitek 2 biochemical profiling (>96% confidence) rather than 16S rRNA gene sequencing, which would provide a more definitive molecular confirmation.

  • The 6 h Stage-1 treatment period represents a minimum tested residence time; a longer residence time might further improve Stage-1 removal and produce an even more favourable substrate for Stage 2.

  • Sampling covered roughly 7 months with three composite samples, which may not capture the full seasonal variability of the wastewater; and (7) results were generated from 15-day batch incubations, so they describe batch-system behaviour and should not be extrapolated directly to continuous-flow system design or to a definitive “minimum” treatment time, since only three time points (Days 5, 10 and 15) were tested.

4.2 Future research directions

The following studies were suggested as priorities for future research.

4.2.1 Parallel controls and statistical verification

Future experiments should incorporate parallel single-treatment controls (including O. splendida-only, carrier-only, and P. fluorescens-only) alongside the combined sequential system. Testing under identical optimal influent qualities and durations, with triplicate data analyzed via ANOVA/Tukey HSD tests, is required to formally define the sequential interaction mechanisms.

4.2.2 Microbiological and temperature profile confirmation

Routine species-specific confirmation of the bacterial cultures within the system should be established using 16S rRNA gene sequencing, combined with growth testing across the full 4 °C–60 °C temperature range to assess seasonal resilience.

4.2.3 Pilot-scale field evaluation

A pilot-scale system (representing a 1/10 scale of the GRSP, approximately 1–10 m3/day) should be evaluated under realistic hydraulic and seasonal variabilities to test the operational stability of the sequential system with real wastewater under field conditions.

4.2.4 Multi-stage interaction analysis

Comprehensive testing should be conducted to explore the specific bio-chemical interactions between the bacterial pre-treatment stage and the subsequent cyanobacterial stage.

4.2.5 Optimization of algal inoculum and photoperiod

Optimization of the working inoculation density of the O. splendida stage, along with variations in the light/dark cycles, should be evaluated to maximize nutrient and heavy metal removal efficiencies.

5 Conclusion

This study evaluated a two-stage biological treatment system—aerobic pre-treatment with Pseudomonas fluorescens followed by cyanobacterial polishing with Oscillatoria splendida—on real municipal wastewater from the Greater Ramadi Sewerage Project, Iraq. Stage 1 (6 h aeration) achieved substantial reductions in COD (81.4%), TDS (62.6%), Ni2+ (75.1%) and Zn2+ (71.7%), confirming P. fluorescens as an effective aerobic pre-treatment organism for organic matter and heavy metals. Stage 2 (15-day O. splendida polishing) produced further reductions across all measured parameters, ranging from 15.0% to 99.5% (TDS), confirming O. splendida as an effective polishing organism for the pre-treated effluent.

A 20% (v/v) dilution of Stage-1 effluent gave the highest removal for most parameters, including BOD5, nitrogen species and most heavy metals, whereas a 40% (v/v) dilution was more effective for phosphate, sulphate, NO2− and copper—an intermediate-dilution effect that appears parameter-specific rather than uniform, and should be confirmed with formal statistical comparison across dilutions before being generalised. Removal generally improved from Day 5 to Day 15 within the tested window; because only three time points were examined, 15 days should be reported as the longest interval tested in this study rather than as an established minimum treatment time, and shorter or intermediate durations were not independently evaluated.

The combined two-stage system outperformed Stage 1 alone for every pollutant examined, consistent with the hypothesis that bacterial pre-treatment improves the substrate available to O. splendida; in the absence of single-treatment controls and formal statistical testing, this should be reported as a beneficial sequential performance rather than a confirmed synergistic effect.

. The system is conceptually well suited to a circular-bioeconomy approach, using solar energy and nutrient-rich pre-treated effluent to grow cyanobacterial biomass without external nutrient inputs, while generating a potentially valuable biomass co-product; these economic and circularity benefits are, at this stage, a promising rationale for pilot testing rather than a demonstrated outcome.

Overall, the two-stage system shows technical promise as a candidate effluent polishing step, and the authors recommend pilot-scale evaluation at the Greater Ramadi Sewerage Project and similar municipal plants in arid regions of the Middle East, together with the additional controls, molecular identification, and statistical validation outlined in Sections 4.1 and 4.2, before its treatment efficiency, cost advantage, or agricultural-reuse suitability are presented as established.

Statements

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Author contributions

HA: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review and editing.

Funding

The author(s) declared that financial support was not received for this work and/or its publication.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was used in the creation of this manuscript. Generative AI was used in the preparation of this manuscript strictly for minor language editing, punctuation formatting, and grammar.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1

    AdityaL.MahliaT. M. I.NguyenL. N.VuH. P.NghiemL. D. (2022). Microalgae-bacteria consortium for wastewater treatment and biomass production. Sci. Total Environ.838, 155871. 10.1016/j.scitotenv.2022.155871

  • 2

    Al-ObaidiM.Al-AnsariN.ChabukA. (2022). Water quality assessment of the euphrates river, Iraq, using water quality indices. Environ. Monit. Assess.194 (2), 113. 10.1007/s10661-021-09688-0

  • 3

    American Public Health Association (APHA) (2017). Standard Methods for the Examination of Water and Wastewater. 23rd ed.: Washington, D.C., USA: American Public Health Association. 10.2105/SMWW.2882.198

  • 4

    ChengS. Y.ShowP. L.LauB. F.ChangJ. S.LingT. C. (2020). New prospects for modified algae in heavy metal adsorption. Trends Biotechnol.37 (11), 1255–1268. 10.1016/j.tibtech.2019.04.007

  • 5

    de GodosI.VargasV. A.BlancoS.GonzálezM. C. G.SialveB.SteyerJ. P.et al (2020). A comparative evaluation of microalgae for the degradation of piggery wastewater under photosynthetic oxygenation. Bioresour. Technol.101 (14), 5150–5158. 10.1016/j.biortech.2010.02.010

  • 6

    DesikacharyT. V. (1959). Cyanophyta. New Delhi, India: Indian Council of Agricultural Research.

  • 7

    García-GalánM. J.RanglováK.Souza Câmara ManoelJ. A.Melero-JiménezI. J.Acién FernándezF. G.Gonzalez-LopezC. V.et al (2021). Biomass production and nutrient removal by Chlorella vulgaris, Arthrospira platensis and mixed microalgae in treated piggery wastewater. Bioresour. Technol.343, 126101. 10.1016/j.biortech.2021.126101

  • 8

    HoltJ. G.KriegN. R.SneathP. H. A.StaleyJ. T.WilliamsS. T. (2004). Bergey's Manual of Determinative Bacteriology. 9th ed.: Baltimore, Maryland, USA: Williams and Wilkins.

  • 9

    MengF.ChaeS. R.DrewsA.KraumeM.ShinH. S.YangF. (2020). Recent advances in membrane bioreactors (MBRs): membrane fouling and membrane material. Water Res.43 (6), 1489–1512. 10.1016/j.watres.2008.12.044

  • 10

    MohapatraR. K.PadhiD.MohantaS.MishraS.BeheraA.MishraY. K.et al (2023). Cyanobacteria as sustainable resource for bioremediation of wastewater: current trends and future prospects. Environ. Res.235, 116570. 10.1016/j.envres.2023.116570

  • 11

    RajneeshSinghS. P.PathakJ.SinhaR. P. (2017). Cyanobacterial factories for the production of green energy and value-added products: an integrated approach for economic viability. Renew. Sustain. Energy Rev.69, 578–595. 10.1016/j.rser.2016.11.110

  • 12

    RenukaN.GuldheA.PrasannaR.SinghP.BuxF. (2021). Microalgae as multi-functional options in modern agriculture: current trends, prospects and challenges. Biotechnol. Adv.36 (4), 1255–1273. 10.1016/j.biotechadv.2018.04.004

  • 13

    ScalesB. S.DicksonR. P.LiPumaJ. J.HuffnagleG. B. (2014). Microbiology, genomics, and clinical significance of the Pseudomonas fluorescens species complex, an unappreciated colonizer of humans. Clin. Microbiol. Rev.27 (4), 927–948. 10.1128/CMR.00044-14

  • 14

    ShahidM.HameedS.ImranA.AliS.van ElsasJ. D. (2021). Root colonization and growth promotion of sunflower (Helianthus annuus L.) by phosphate solubilizing Pseudomonas fluorescens. Biologia67 (1), 148–155.

  • 15

    SinghR.PaulD.JainR. K. (2020). Biofilms: implications in bioremediation. Trends Microbiol.14 (9), 389–397. 10.1016/j.tim.2006.07.001

  • 16

    StanierR. Y.KunisawaR.MandelM.Cohen-BazireG. (1971). Purification and properties of unicellular blue-green algae (order chroococcales). Bacteriol. Rev.35 (2), 171–205. 10.1128/br.35.2.171-205.1971

  • 17

    United Nations Environment Programme (UNEP) (2021). Progress on Wastewater Treatment: Global Status and Acceleration Needs for SDG 6. Nairobi, Kenya: UNEP.

  • 18

    WangZ.WuZ.TangS. (2021). Extracellular polymeric substances (EPS) properties and their effects on membrane fouling in a sequencing batch membrane bioreactor. Water Res.43 (6), 1533–1539. 10.1016/j.watres.2008.12.049

  • 19

    WilleyJ. M.SherwoodL. M.WoolvertonC. J. (2011). Prescott's Microbiology. 8th ed.: McGraw-Hill.

Summary

Keywords

bioremediation, heavy metal, nutrient removal, oscillatoria splendida, pseudomonas fluorescens, wast water treatment

Citation

Ali HA (2026) A two-stage biological system integrating pseudomonas fluorescens and oscillatoria splendida for heavy metal and nutrient removal from municipal wastewater. Front. Environ. Eng. 5:1923409. doi: 10.3389/fenve.2026.1923409

Received

29 June 2026

Revised

16 September 2026

Accepted

22 September 2026

Published

10 November 2026

Volume

5 - 2026

Edited by

Lakhan Kumar, Maulana Azad National Institute of Technology, India

Reviewed by

Gulnaziya Issabayeva, Universiti Tunku Abdul Rahman, Malaysia

Ram Kumar, Central University of South Bihar, India

Updates

Copyright

*Correspondence: Hala Arshad Ali,

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article