Abstract
In engineering, one of the common problems is determining head losses in operational structures. Determining this parameter has been the focus of studies for many years. As a result, several approaches have been developed with the main aim of minimising the discrepancies between experimental values and theoretical values. Until now, this determination has been made by considering the characteristics of the structure in new condition and under ideal operating conditions. This does not take into account the environment and the actual operating conditions of each structure. With this in mind, we have proposed another method for determining head loss in a pressurised pipe. To do this, we modelled the penstocks of two hydroelectric dams in Cameroon (the Songloulou and Lagdo dams) in Gambit 2.2 software. Next, we used Fluent 6.2.2 to simulate the flow of clear water through this structure in order to see the impact of the structure’s configuration (layout) on the determination of the friction coefficient and, consequently, the pressure drop. This simulation initially allowed us to see a variation in the velocity in the pipe, despite the inlet velocity. This clearly shows the limitations of the standard analytical approach, which considers a constant velocity for a section of pipe, regardless of its length. Knowing that a variation in velocity implies a variation in friction, we graphically generated the evolution of friction on each wall. This allowed us to confirm that for the same section of pipe and at the same velocity, we have different values for the friction coefficient. We then proposed an improved expression that takes into account the variation in key parameters during the operation of structures. Similarly, we proposed a more effective and contextualised alternative approach for structures in their various forms and environments.
1 Introduction
Mankind is endowed with an enormous amount of clean, renewable energy provided by nature. Hydroelectric power, or hydropower, is electrical energy obtained by converting the hydraulic energy of various water flows (rivers, waterfalls, ocean currents, etc.) (). The kinetic energy of the water current is transformed into mechanical energy by a turbine, then into electrical energy by an alternator ().
The purpose of penstocks is to transfer water from intake structures (tunnels, canals, etc.) to the installations that converts hydraulic energy into electrical energy (turbines in a hydroelectric plant) (). They are made up of sections with singularities (slopes, obstacles, ravine crossings, etc.) where local hydrodynamic pressures take on high values. The hydraulic plant thus supports a pressure of the order of the water flow at the feeder, but these are reduced by head loss effects (). The various materials that may be suitable for penstocks are: steel, polyethylene and reinforced concrete (). In order to evaluate the flow rate in a pipe, it is important to first determine the head losses it generates. In addition to the singularities present on the supply lines, these head losses are also caused by friction on the walls (). It is therefore essential to determine the friction coefficient f beforehand. In this document, we will therefore study the hydraulic characteristics caused by the penstock walls on the flow in transit. The basic analytical and numerical approaches used in the search for engineering solutions are applied in combination, in order to achieve the set objective.
To date, the friction coefficient has been determined using two main approaches. These approaches are the deduction approach using charts (or diagrams) and the calculation approach, which encompasses a multitude of methods. However, regardless of the approach used, it is calculated to determine the pressure drop. This is where the main problem we will address in this document lies. In order to analytically determine the two elements discussed in this paper (friction coefficient and pressure drop), the key parameters for a structure are considered to be invariant regardless of the configuration of the structure and throughout its use. The diameter considered is the manufacturer’s diameter. The flow rate considered is that of the structure when new and assumed to be constant in a section of the pipe. The wall roughness adopted is that provided by the pipe manufacturer.
Studies conducted today using CFD allow us to understand the behaviour of fluid in penstocks. This shows us that these parameters cannot in fact be constant, as assumed in the standard analytical approach. If we consider flow rate alone, several studies have shown that it varies within the same section of pipe, regardless of its geographical location (; ; ; ).
In this document, we will study the hydraulic characteristics caused by the walls of the penstock on the flow passing through it. To do this, we will adopt a numerical approach coupled with an analytical approach, with a view to identifying a more suitable expression for finding engineering solutions. The main objective is to determine values for our two elements that best approximate the reality of each structure under consideration. We will characterise the friction in the penstock of two local dams (the Songloulou and Lagdo dams) in order to use the results to propose more suitable approaches that can be generally applied by hydraulic engineers. Each proposed approach will provide more accurate values and reduce the margin of error when determining head loss in hydraulic structures in general. This can be done by simply applying one of the proposed approaches to one of the standard analytical methods. This study is based on preliminary analyses of flow in the penstock of a hydroelectric dam in Cameroon. There are no previous studies other than the work we conducted are available regarding friction parameters in the penstocks of the 2 dams under study.
2 Methods
2.1 Current approaches
The relationship for determining the coefficient of friction in the penstocks was first given by Chezy in 1775 cited by Munro (). Various researchers subsequently improved the relationship. These include Poiseuille (), who developed the relationship for laminar flow, and Williams and Hazen () and Blasius (), who developed relationships for turbulent flow. However, their relationships are not widely used for penstock applications, due to the low velocity range of one, or the low flow rate range of the other in a real-life context. The relations developed by Darcy-Weisbach (), Manning () and Scobey () are the most commonly used to determine this coefficient of friction in penstocks.
Nikuradse () carried out experiments on uniformly rough pipes and developed curves relating the coefficient of friction (f) and Reynolds number (Re) to determine the coefficient of friction in the Darcy-Weisbach equation. Kármán () and Prandtl () developed the empirical relationship for these curves. These curves and relationships have limited application because, in practice, roughness in pipes is not uniform but irregular and wavy. Colebrook-White () developed a relationship between Re and f by carrying out experiments on commercially available pipes, taking into account the effect of the height of the roughness in the pipes. However, the equation they developed is implicit, which requires iterative methods for a solution. Moody () developed curves corresponding to different values of relative roughness (k/D) in order to give direct values of the coefficient of friction based on the Colebrook-White relationship.
Multiple experiments carried out by the English engineer Osborne Reynolds led to the discovery of the specific characteristics of a real fluid and the identification of two possible flow categories: laminar and turbulent ().
Turbulence is the state of a fluid whose flow is so irregular that its velocity varies randomly at any point in space. According to Cadot (), flows are turbulent and unpredictable by nature. Today, turbulence is at the heart of the fundamental problems of classical physics. It is essentially characterized by the existence of eddies of all sizes, unlike laminar flow, which takes place on a precise scale.
In general, the current approach consists of determining the coefficient of friction using one of the methods presented below, considering the key parameters of the calculation to be invariant and constant.
2.1.1 Determining the coefficient of friction
For laminar flow in a horizontal cylindrical pipe, the coefficient of friction is given by Poiseuille ():
For turbulent flow, the empirical equation proposed by Colebrook-White is by far the most famous.
This equation is an implicit equation that is difficult to manipulate. Other researchers have proposed explicit formulas for different regimes, such as the one by Poiseuille mentioned above. We also note the case of Blasius (), who proposed a formula for smooth turbulent flow, given by Equation 3 below. Similarly, Blench () provided a formula for rough turbulent flows, given by Equation 4.
In a similar manner, Moody proposed a diagram based on the Colebrook equation. For use in turbulent conditions, one calculates the relative roughness and select the corresponding curve (0.02 or 5.10−4 in this case).
Alongside these standard formulas, a new generation of researchers has developed either explicit expressions of the Colebrook-White formula, or new approaches for calculating the coefficient of friction.
developed the explicit relationship to determine the coefficient of friction in terms of Re and the relative roughness height (k/D) as a function of the Colebrook-White relationship according to the following equation:
suggests using the following formula Equation 6:
have developed a relationship that is valid for 3 × 103 < Re < 3 × 108, and 0 ≤ (ε/D) ≤ 5 × 10−2. The formula is presented in Equation 7:
Using different solutions of Lambert’s W function, proposes an explicit form for the Colebrook-white equation as follows:
Using a different approach, have provided an explicit procedure for calculating the friction factor using the Adomian decomposition method. For the laminar regime, they propose the following formula:where:and for turbulent flow:
It should be noted that this formula was developed for a specific Bingham fluid.
Following the same line of reasoning, Morrison () developed a new, explicit and relatively simple correlation of the coefficient of friction for smooth pipes.
2.1.2 Determination of pressure loss
Darcy-Weisbach () expressed the linear head loss gradient, also known as the friction gradient. This depends on the friction coefficient, the flow volume and the geometric characteristics of the structure.
2.2 Experimented approach
The experimental approach models the structure numerically. It involves creating an incremental zone near the walls to observe the influence of roughness on flow, then visualise the evolution of the friction coefficient throughout the entire pipe. Theoretically, this approach takes into account the configuration of the structure, and the variation in flow structure within the structure. At the conclusion of this work, a more convenient method will be identified for safer application. Thus, the modelling itself was carried out using Gambit 2.2 for its graphical rigour, followed by a simulation in Fluent 6.2.2 for its compatibility with the modelling software, as well as its precision and the quality of its results. The mesh is quadrilateral to reduce calculation errors, with a tighter mesh near the walls. The SIMPLEC algorithm was adopted with the “Power law” discretisation scheme as it is more recommended for its accuracy and calculation time (; ). The fluid is incompressible and the approach flow is considered stationary. Figures 2, 3 below show the mesh of the two supporting structures.
FIGURE 1
FIGURE 2
FIGURE 3
It should be noted that this work is a continuation of the study available in the literature (), where details on the validation of the model are presented. These 2 dams are notable for having different configurations and being located in different sedimentation zones compared to the other dams in the country that draw from the same river as the Songloulou dam. Other studies supporting this conclusion can also be cited ((; ))
3 Results and implications
The results present the impact of each approach separately. Subsequently, a brief comparative study will highlight the impact of our approach.
3.1 Existing approach
The existing approach is to determine the coefficient of friction using one of the usual formulas, or by deduction from the Moody diagram. The roughness value used to calculate the friction coefficient is the one estimated based on a simple deduction from the condition of the structure (its age). Tables 1, 2 below show the results obtained from the Colebrook-White formula for a steel pipe in a roughness ranging from new (ε = 0.03 mm) to worn (ε = 1 mm) according to (), considering only the intermediate values.
TABLE 1
| Velocity (u) | Epsilon (ε) | Relative roughness (ε/D) | Friction coefficient (f) |
|---|---|---|---|
| 3.5; 3.7; 3.87 | 0.05 | 0.00833 | 0.03570 |
| 0.09 | 0.01500 | 0.04371 | |
| 0.3 | 0.05000 | 0.07156 | |
| 0.8 | 0.13333 | 0.12003 |
Evolution of the friction coefficient in the Songloulou pipe as a function of its age.
TABLE 2
| Velocity (u) | Epsilon (ε) | Relative roughness (ε/D) | Friction coefficient (f) |
|---|---|---|---|
| 4.3; 4.5; 4.73 | 0.05 | 0.00781 | 0.03495 |
| 0.09 | 0.01406 | 0.04270 | |
| 0.3 | 0.04688 | 0.06946 | |
| 0.8 | 0.12500 | 0.11549 |
Evolution of the friction coefficient in the Lagdo pipe as a function of its age.
We can see that for each value of roughness ε, the friction coefficient f remains the same despite the approach flow. Furthermore, results not presented here suggests that this coefficient is constant in a given section of duct, which is not exactly the case.
When trying to determine f from Moody’s diagram, we see that it will be the maximum according to the Reynolds number prevailing in each structure.
3.2 Experimental approaches
This is the friction coefficient obtained graphically on each point making up the sections of our penstock. To do this, we assessed the maximum thickness of the roughness that we will consider to be the actual absolute roughness in use, and for the structure in new condition. After studying a zone ≤15 mm near the wall, we found that the maximum value of ε is approximately 5 mm. This is justified by the fact that turbulent friction begins to drop considerably as we move towards the axis of the pipe (ε > 5 mm). Although determined graphically, we can easily identify the evolution of turbulent friction in each section of the penstock based on the parameters of its environment. It should be noted that the plots presented are only determined in straight sections.
3.2.1 Application to the lagdo dam
This is a dam whose penstocks consist of three straight sections. Studies were conducted on each of these sections, considering two walls (the Bottom and Top). Figures 4, 5 below illustrate the evolution of turbulent friction on these two pipe walls for the minimum flow through the dam.
FIGURE 4
FIGURE 5
From these graphs, we can see that the friction coefficient is not constant throughout a pipe. It is neither constant in a section of the pipe nor on a wall of the section in question. Figure 6 below provides a clear summary of this statement.
FIGURE 6
Thus, these results clearly show us the limitations of the theoretical and analytical approach based on the use of standard formulas.
3.2.2 Application to the songloulou dam
This is a dam whose penstocks consist of two straight sections. As in the previous case, the studies were conducted on each of the sections, considering two walls (the lower and upper walls). Figures 7, 8 below illustrate the evolution of turbulent friction on these two pipe walls for the minimum flow through the dam.
FIGURE 7
FIGURE 8
We also observe a significant variation in the coefficient of friction in these figures, as in the previous case. This variation is more visible in the above figures than in Figure 9 below.
FIGURE 9
3.3 Consequences
Once we obtained of the various profiles (i.e., the evolution of friction), we integrated them into Moody’s diagram, the basic tool used by hydraulic engineers. The aim was to compare the two approaches, and at the same time to deduce how they might be reconciled. For this study, we consider a Moody diagram containing previous research conducted by Levin (), which is of great interest to hydraulic engineers. It should be noted that Levin () conducted precise tests on the eight types of coating commonly applied to penstocks built in France and many other countries. We also specify that these tests were carried out over a period of 2 years, with one test performed every 2 months. For our study, it is important to note that the fluid used is clear water (without considering the surrounding sedimentation). This had the effect of minimizing the value of the friction coefficient found for each study point, and consequently reducing the turbulent friction existing in the structure.
3.3.1 Case of songloulou dam
Based on Moody’s diagram completed by Levin (), we integrated the data obtained in the Songloulou power plant penstock, as shown in Figures 10a,b below.
FIGURE 10
We can see that turbulent friction for the two walls considered is approximately similar, and lies within the hydraulically smooth turbulent limit regardless of the section examined. Thus, we can conclude that the penstock’s configuration allows us to minimise turbulent friction (the case of Songloulou, for example,).
3.3.2 Case of lagdo dam
Still on Moody’s diagram, we integrated the data obtained from the penstock of the Lagdo hydroelectric power station. The results are shown in Figures 11a,b below.
FIGURE 11
From these two figures, we can see that the turbulent friction follows a similar pattern in the first two portions. It is also in the same zone for both walls. Although, it is more pronounced in the smooth rough turbulent transition zone.
Unlike the first two sections, the third section is characterized by a significant variation in turbulent friction depending on the wall. For the lower wall, turbulent friction is essentially linear and falls within the same value ranges (Figure 11a). On the upper wall, however, turbulent friction varies considerably, with a much higher value observed in this section. In fact, it is in this section that we observe the highest value of turbulent friction in the pipes studied. However, we note that this parameter is in the smooth turbulent zone for portion 3.
In general, our results lie in the hydraulically smooth turbulent boundary towards the hydraulically rough transition. Based on the results obtained by Levin (), our findings are similar to those of polyurethane and vinyl coatings applied with an airless spray gun. The differences observed are mainly due to the diameters used in both cases, as well as the intrinsic characteristics of the fluid used.
3.3.3 Proposed approach for determining absolute roughness
Absolute roughness represents the size of asperities present on pipe walls. However, the studies considered today as references are not in agreement. Levin (; ), for example, contested the reference values for calculating head loss. Others, such as Goldstein (), Hunsaker and Rightmire (), Blench (), and Réméniéras (), had previously raised this issue in their research.
Based on these observations and the field data, we derive the following Formula 13 for determining the actual roughness at a site.
for εreal= εsite
And ε0= εconst= εmanufacturer
We have:
= εparticles +ε (T).
Where.
- ❖
εsite= actual on-site roughness;
- ❖
ε0= εconst= roughness of a new pipe supplied by the manufacturer;
- ❖
εzone(T+Δt) = pipe roughness at age T, after a period of Δt months without cleaning;
- ❖
ε (T) = pipe roughness at age T;
- ❖
ε (Δt) = pipe roughness after Δt months without cleaning;
- ❖
εparticles= roughness of the particles under consideration.
It should be noted that the expression of εzone presented above (13) is a simplified expression that complements that proposed by Mostkov () based on the work of Altschoul and Kamerschteyn () who sought the value of ɛ after a time t (in years), and gave the roughness directly by:where αt = age-dependent roughness coefficient.
However, we believe that this formula does not take all the relevant parameters, according to their interpretations. We deduce from their justifications that this expression (εt= ε0+ αt) corresponds to a single term (ε (T)) in the one we propose, hence:
Further studies are being conducted on the evolution of the parameters ε (T) and ε (Δt). A preliminary study (still ongoing) shows that ε (T) initially grows linearly with time, then Cataclysmically if a coating is not applied within the defined usage time. Similarly, the same study shows that ε (Δt) initially grows linearly, then tends to become constant after a certain period. In general, it must be stated that determining the exact expressions for these two parameters is difficult, as they also depend strongly on the physico-chemical characteristics of the fluid being transited. This implies that the value of the parameter εzone(T+Δt) can only be approximated.
3.3.4 Proposed approach for determining the coefficient of friction
Based on the results of this study, we can see that another simple approach can be adopted in addition to conventional methods for calculating the coefficient of friction. Based on our tracings, we observe that it is highly advantageous to graphically determine the evolution of the friction coefficient in a section of duct. This only requires a good incrementation of the study area, and the accuracy of the input data. We therefore recommend a graphical determination of the friction coefficient. This method seems more appropriate because it takes into account real and contextual parameters that analytical determination could not consider.
For the analytical approach, we recommend the use of a new expression for the absolute roughness present in the usual formulas. This expression is denoted εeq for equivalent ε and is equal to:
Where γ is a shape coefficient that depends on the shape of the pipe section. It is 1.33 for a circular pipe and varies between 1.2 and 1.25 for an ovoid pipe. These values are derived from observations of the three-dimensional nature of flow in a pipe, taking into account the various poles of our wall’s cross-section. This leads us to values that are nearly empirical, thereby placing us in the most unfavorable scenario to ensure the quality of the resulting outcome.
Similarly, for the Reynolds number, we recommend using a new designation based on the time of the study. For example, in Equations 4, 5, we would have:
This is justified by the fact that for a pipe section with diameter D taken at a given moment i (Di), the Reynolds number Re will always depend on the absolute roughness ε prevailing near the walls.
3.3.5 Proposed approach for determining linear head loss
Although the parameters proposed above are generally applicable, this paper aims to improve the expression given by Darcy-Weisbach for structures where the flow regime is always fully turbulent. Based on these new parameters, we have shown that the expression for linear head loss in a section of pipe assumed to be straight must be rewritten, and that the value must be evaluated at several points along the pipe in order to obtain an average value. This leads us to propose the following improved expression for a specific point in the pipe:
with.
- ❖
Total Head loss at point j of section i;
- ❖
Linear head loss gradient at point j of section i;
- ❖
= Coefficient of friction at point j of section i;
- ❖
= Flow rate (function of time) squared at point j of section i;
- ❖
= Hydraulic diameter (function of time) power 5 at point j of section i;
- ❖
= Length of point j in section i.
Using this approach, the expression for head loss in a section of pipe yields an average value, the maximum and minimum can be determined using the previous approach:
where.
- ❖
Average linear head loss in the considered section;
- ❖
Average total head loss in the considered section;
- ❖
= Average friction coefficient in the considered section;
- ❖
= Average flow rate (function of time), squared in the considered section;
- ❖
= Average hydraulic diameter (function of time) raised to the 5th power in the considered section;
- ❖
Average length of the considered section.
In practical terms, we observe a variation in flow rate over time. This observation has also been made by other researchers, such as Altschoul and Kamerschteyn (). This variation for the same approach flow rate is caused by the hydraulic diameter Dh, which also varies over time. This diameter is reduced by the accumulation of sediments, which affects the friction coefficient in the pipe. We can therefore conclude that the pressure drop in a straight pipe is not only non-constant at a given time t, but also changes over time. This is in line with the statement by Levin [39, §3, pp48] that “We can see that the effect of age is significant and becomes more pronounced as the pipe diameter decreases”.
Tables 3, 4 below show the values obtained from the Colebrook-White expression, taking into account our proposed approach for determining εeq.
TABLE 3
| Vitesse (V) | Epsilon (ε) | Rugosité relative (ε/D) | Coef de friction (f) |
|---|---|---|---|
| 3.7; 3.87 | 0.065 | 0.01083 | 0.03899 |
| 0.1197 | 0.01995 | 0.04862 | |
| 0.399 | 0.0665 | 0.08209 | |
| 1.064 | 0.17733 | 0.14362 |
Evolution of the friction coefficient in the pipe as a function of its age, taking into account εeq.
TABLE 4
| Vitesse (V) | Epsilon (ε) | Rugosité relative (ε/D) | Coef. de frottement (f) |
|---|---|---|---|
| 4.3; 4.5 | 0.065 | 0.01015 | 0.03813 |
| 0.1197 | 0.01870 | 0.04744 | |
| 0.399 | 0.06234 | 0.07951 | |
| 1.064 | 0.16625 | 0.13771 |
Evolution of the friction coefficient in the pipe as a function of its age, taking into account εeq.
Figures 12a,b below summarises the impact of this new approach on the results obtained analytically. In these figures, f(old) represents the variation of the friction coefficient as a function of relative roughness (ε/D), as presented in Tables 1, 2, obtained from Equation 5. f(new) represents this same parameter as a function of relative roughness (ε/D), as presented in Tables 3, 4, obtained this time from Equation 21.
FIGURE 12
We note that, when considering ɛ as it is currently defined, the value of the friction coefficient is underestimated and, consequently, so is the head loss. Although the margin is negligible for a newly commissioned pipeline, it is significant as the pipeline clogs. Given that sediments are present as soon as the penstocks are commissioned, we can conclude that our approach is more appropriate for minimising actual head losses on site.
4 Conclusion
The goal of this study was to propose a new approach for evaluating head loss in the penstock of a hydroelectric dam. We first reviewed the approaches commonly used to date. From Chezy’s 1775 relation, which was the starting point for determining friction losses in the penstock, to Colebrook-White, who were inspired by the work of Nikuradse, Prandtl and Von Kármán, the analytical approach for determining the coefficient of friction remains a problem. Although several researchers have improved on existing expressions, the fact remained that the results were still not unanimous. It is with this in mind that we have proposed an approach based on the analytical method, as well as another based on the graphical deduction of the coefficient of friction. Our approach consists first of reviewing the notation of absolute roughness, which is fundamental to determining the coefficient of friction. After that, we proposed an improved expression that can be integrated into the usual expressions for determining the coefficient of friction. Finally, we integrated this expression into a few formulas while presenting their impact on the results obtained. Given that the friction coefficient is one of the key parameters in determining head loss, we believe that this approach will yield better results for each structure considered. We support this assertion by noting that the values obtained using the conventional method are more limited when applied to real structures. This observation was already highlighted by Levin in his work in 1972. However, we have noticed that despite the proposed approach, it will be difficult to determine the exact value of the pressure drop. This is because the parameters currently considered by a large number of researchers only represent some of the aspects that need to be taken into account.
Statements
Data availability statement
The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.
Author contributions
TM: Conceptualization, Data curation, Formal Analysis, Investigation, Resources, Writing – original draft. T-TD: Validation, Visualization, Writing – review and editing. KB: Supervision, Validation, Writing – review and editing.
Funding
The author(s) declared that financial support was not received for this work and/or its publication.
Acknowledgments
We would like to thank the young researchers who helped us improve the quality of this document. They are Mbohlieu Tchawe Yossa, Ph. D of the Department of Geology at the University of Buea and Nkontchou Ngongang François Le-Grand, Ph. D of the Department of Mechanical Engineering at the University of Ngaoundere.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
AchourB.BedjaouiA.KhattaouiM.DebabecheM. (2002). Contribution au calcul des écoulements uniformes surface libre et en charge. J. Lar.2, 7–36.
2
AdamkowskiA.KrzemianowskiZ.JanickiW. (2009). Improved discharge measurement using the pressure-time method in a hydropower plant curved penstock. Jour. Eng. Gas Turb. Power.131, 6. 10.1115/1.3078794
3
AltschoulK. (1949). Augmentation de la résistance des conduites durant leur exploitation (russe). Const. Hyd. N7, 1D4H.
4
BlasiusP. R. H. (1913). Das Aehnlichkeitsgesetz bei Reibungsvorgangen in Flüssigkeiten. Forschungsheft131, 1–41. 10.1007/978-3-662-02239-9_1
5
BlenchT. (1952). Les Formules D'Écoulement et D'Hydraulique Pratique, La Houille Blanche. N°4, 596–613. 10.1051/lhb/1952040
6
BonoU. (1934). Problèmes constructifs relatifs aux conduites forcées et ouvrages accéssoires. La Houille Blanche29 (5), 129–146.
7
BrkicD. (2011). An explicit approximation of the colebrook equation for fluid flow friction factor. Petrol. Sci. Tech.29, 1596–1602. 10.1080/10916461003620453
8
CadotO. (2013). Introduction à la turbulence, cours de l’ENSTA-ParisTech 2A, École d’ingénieur. Introduction à la turbulence, ENSTA-ParisTech, Fr., pp.83.
9
ColebrookC. F.WhiteC. M. (1939). Turbulent flow in pipes, with particular reference to the transition region between the smooth and rough pipe laws. Jour. Inst. Civ. Eng.11 (4), 133–156. 10.1680/ijoti.1939.13150
10
DanishM.KumarS.KumarS. (2011). Approximate explicit analytical expressions of friction factor for flow of bingham fluids in smooth pipes using Adomian decomposition method. Commun. Nonlinear Sci. Numer. Simul.16 (1), 239–251. 10.1016/j.cnsns.2010.03.013
11
DarcyH. (1857). Recherches Experimentales Relatives Au Mouvement De L'Eau Dans Les Tuyaux, 2 Volumes. Mallet-Bachelier. Paris, 268 p and atlas. (“Experimental Research Relating to the Movement of Water in Pipes”).
12
ElieF. (2014). Les conduites forcées: principes, aménagements, sécurités, Rapport des travaux, 19p. Available online at: http://fred.elie.free.fr.
13
FangX.XuaY.ZhouZ. (2011). New correlations of single-phase friction factor for turbulent pipe flow and evaluation of existing single-phase friction factor correlations. Nucl. Eng. Des.241, 897–902. 10.1016/j.nucengdes.2010.12.019
14
Fluid-flow: absolute (2012). Fluid-Flow: Absolute-Roughness-Of-Pipe-Material, Articles, neutrium.net.
15
GoldsteinS. (1938). Modern Developments in Fluid Dynamics: An Account of Theory and Experiment Relating to Boundary Layers, Turbulent Motion and Wakes, 1. Clar. Press.
16
HunsakerJ. C.RightmireB. G. (1947). Engineering Application of Fluid Mechanics. Mc Graw Hill.
17
LevinL. (1966). Difficultés du calcul des pertes de charge linéaires dans les conduites forcées, La Houille Blanche. N°1, 41–54. 10.1051/lhb/1966002
18
LevinL. (1972). Etude hydraulique de huit revêtements intérieurs de conduites Forcées. La Houille Blanche58 (4), 263–278. 10.1051/lhb/1972020
19
ManningR. (1891). On the flow of water in open channels and pipes. Trans. Inst. Civ. Eng. Irel.20, 161–207.
20
MichelH. (1975). Mécanique Des Fluides Appliquée Aux Problèmes D’Aménagement Et D’Énergétique, Eyrolles.
21
MoodyL. F. (1944). Friction factors for pipe flow. Trans. ASME66 (8), 671–684. 10.1115/1.4018140
22
MorrisonF. A. (2013). Data Correlation for Friction Factor in Smooth Pipes, Department of Chemical Engineering. Mich. Tech. Univ., Houghton, MI Available online at: www.chem.mtu.edu/∼fmorriso/DataCorrelationForSmoothPipes2013.pdf.
23
Mostkov (1954). Formulaire D'Hydraulique (Russe). Moscou, 159.
24
MunroR. (2017). “Chézy formula,” in Encyclopedia of Engineering Geology, Encyclopedia of Earth Sciences Series. Editors BobrowskyP.MarkerB. (Cham: Springer). 10.1007/978-3-319-12127-7_50-1
25
NikuradseJ. (1933). Stroemungsgesetze in rauhen rohren. Ver. Dtsch. Ing. Forsch.361.
26
Patankar (1980). Numerical Heat Transfer and Fluid Flow, Series in Computational and Physical Processes in Mechanics and Thermal Sciences. McGraw-Hill Book Company.
27
Poisseuille (1846). Recherches expérimentales sur le mouvement des liquides dans les tubes de très petits diamètres. Mémoires présentés divers savants à l'Académie R. Sci. l'Institut Fr.IX, 433–544.
28
Prandtl (1933). Neuere Ergehnisse Der Turhulenzforschung, Z.V.D.L. Band 77.
29
RéméniérasG. (1953). Le coefficient de perte de charge des grandes conduites (The head loss coefficient of large pipelines). Tech. Mod. Const. N3.
30
ScobeyF. C. (1930). The Flow of Water in Riveted and Analogous Pipes, 150. Washington DC: USDA, 45.
31
Sécurité des conduites forcées (2013). Bureau D’Étude Technique Et De Contrôle Des Grands Barrages. (STEEGB/BETCGB) - INERIS: 35p.Rapport d’étude.
32
SwameeP. K.JainA. K. (1976). Explicit equations for pipe-flow problems, jour. Of the hyd. Div102 (5), 657–664. 10.1061/JYCEAJ.0004542
33
TchaweT. M. (2019). Thèse En Génie Mécanique Et Productique/Ingénierie Des Equipements Et Productique, Université De Ngaoundéré, 270p.Etude et caractérisation du frottement turbulent dans la conduite forcée et dans le barrage de prise d’eau d’une station hydroélectrique: cas des barrages du Cameroun.
34
TchaweT. M.DjiakoT.KenmeugneB.Tcheukam-TokoD. (2018). Numerical study of the flow upstream of a water intake hydroelectric dam in stationary regime. Am. Jour. En. Res.6 (2), 35–41. 10.12691/ajer-6-2-1
35
TchaweT. M.NkontchouN. F.DjiakoT.KenmeugneB.Tcheukam -TokoD. (2022). Numerical evaluation of turbulent friction on walls in the penstock of the trois-gorges dam by the swamee-jain method, world acad. Of sc., eng. And tech. Int. Jour. Of civil and env. Eng16, 6. 10.12691/ajer-6-2-1
36
TchaweT. M.TientcheuN. M.DjiakoT.Nkontchou NgongangF. L.Tcheukam-TokoD.KenmeugneB. (2024a). Graphical application of the colebrook-white equation to the songloulou and lagdo dam penstocks. DS J. Digital Sci. Technol.3 (2), 1–8. 10.59232/DST-V3I2P101
37
TchaweT. M.Nkontchou NgongangF.TientcheuN. M.DjiakoT.Tcheukam-TokoD.KenmeugneB. (2024b). Determination of the coefficient of friction in the penstock of a hydro-electric dam: application of two approaches. Hydrology Res.55 (10), 1030–1042. 10.2166/nh.2024.054
38
TchaweT. M.NkontchouN. F.TientcheuN. M.DjiakoT.DjeumakoB.Tcheukam-TokoD.et al (2024c). Comparative analysis of friction coefficient evolution in hydroelectric dam penstocks: Theoretical vs. numerical methods. Glob. Jour. Res. Eng. A Mech. Mech. Eng.24 (2), 13–21. 10.34257/GJREAVOL24IS2PG13
39
U.S. Energy Information Administration (EIA), Form EIA-923 Power Plant Operations Report (2022). Indep. Statistics And Analysis. Final Data
40
Van DoormaalJ. P.RaithbyG. D. (1984). Enhancements of the SIMPLE method for predicting incompressible fluid flows. Numer. Heat. Transf.7, 147–163. 10.1080/01495728408961817
41
VonK. T. (1930). Mechanische Ahnlichkeit Und Turbulenz, 1930.Nachr. Ges. Wiss'ensch., Güttingen, N°5.
42
WangC.MengT.HuH.ZhangL. (2012). Accuracy of the ultrasonic flow meter used in the hydroturbine intake penstock of the three gorges power station. Flow Meas. Inst25, 32–39. 10.1016/j.flowmeasinst.2011.12.003
43
WilliamsG. S.HazenA. (1905). The Discharge over Weirs. 1st ed. Wiley, p75.Hydraulic tables: showing the loss of head due to the friction of water flowing in pipes, aqueducts, sewers, etc.
Summary
Keywords
friction coefficient, head losses evaluation, hydroelectric dam, penstock, theorical and graphical deduction
Citation
Moukam TT, Dénis T-T and Bienvenu K (2026) Improving the assessment of the head losses in the penstock of a hydroelectric dam. Front. Environ. Eng. 5:1981862. doi: 10.3389/fenve.2026.1981862
Received
28 August 2026
Revised
01 October 2026
Accepted
10 October 2026
Published
11 November 2026
Volume
5 - 2026
Edited by
Sherub Phuntsho, University of Technology Sydney, Australia
Reviewed by
Panayiotis Dimitriadis, National Technical University of Athens, Greece
Christian Cahyono, Binus University, Indonesia
Updates
Copyright
© 2026 Moukam, Dénis and Bienvenu.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Tchawe Tchawe Moukam, moukam.tchawe@univ-ndere.cm, christophetchawe88@gmail.com, christophetchawe@yahoo.fr
ORCID: Tchawe Tchawe Moukam, orcid.org/0000-0001-5449-7954
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.