<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Mater.</journal-id>
<journal-title-group>
<journal-title>Frontiers in Materials</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Mater.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2296-8016</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1906993</article-id>
<article-id pub-id-type="doi">10.3389/fmats.2026.1906993</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Mortar composites incorporating VO<sub>2</sub>/MWCNT solid&#x2013;solid nanophase change material for passive indoor temperature regulation</article-title>
<alt-title alt-title-type="left-running-head">Villegas-M&#xe9;ndez et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fmats.2026.1906993">10.3389/fmats.2026.1906993</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Villegas-M&#xe9;ndez</surname>
<given-names>J. R.</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing - original draft</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Fragoso-Fern&#xe1;ndez</surname>
<given-names>C. Y.</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal Analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x26; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/">Writing - review and editing</role>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gonz&#xe1;lez-L&#xf3;pez</surname>
<given-names>J. R.</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x26; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/">Writing - review and editing</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Guerra-Coss&#xed;o</surname>
<given-names>M. A.</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x26; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/">Writing - review and editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Figueroa-Torres</surname>
<given-names>M. Z.</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3347497"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing - original draft</role>
</contrib>
</contrib-group>
<aff id="aff1">
<institution>Facultad de Ingenier&#xed;a Civil, Universidad Aut&#xf3;noma de Nuevo Le&#xf3;n</institution>, <city>San Nicol&#xe1;s de los Garza</city>, <state>Nuevo Le&#xf3;n</state>, <country country="MX">Mexico</country>
</aff>
<author-notes>
<corresp id="c001">
<label>&#x2a;</label>Correspondence: M. Z. Figueroa-Torres, <email xlink:href="mailto:m.zyzlila@gmail.com">m.zyzlila@gmail.com</email>, <email xlink:href="mailto:mayra.figueroatrr@uanl.edu.mx">mayra.figueroatrr@uanl.edu.mx</email>
</corresp>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2026-09-08">
<day>08</day>
<month>09</month>
<year>2026</year>
</pub-date>
<pub-date publication-format="electronic" date-type="collection">
<year>2026</year>
</pub-date>
<volume>13</volume>
<elocation-id>1906993</elocation-id>
<history>
<date date-type="received">
<day>11</day>
<month>06</month>
<year>2026</year>
</date>
<date date-type="rev-recd">
<day>08</day>
<month>07</month>
<year>2026</year>
</date>
<date date-type="accepted">
<day>14</day>
<month>07</month>
<year>2026</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2026 Villegas-M&#xe9;ndez, Fragoso-Fern&#xe1;ndez, Gonz&#xe1;lez-L&#xf3;pez, Guerra-Coss&#xed;o and Figueroa-Torres.</copyright-statement>
<copyright-year>2026</copyright-year>
<copyright-holder>Villegas-M&#xe9;ndez, Fragoso-Fern&#xe1;ndez, Gonz&#xe1;lez-L&#xf3;pez, Guerra-Coss&#xed;o and Figueroa-Torres</copyright-holder>
<license>
<ali:license_ref start_date="2026-09-08">https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
<license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p>
</license>
</permissions>
<abstract>
<p>Phase change materials (PCMs) have emerged as promising materials for improving the thermal performance of building envelopes. In this study, a solid&#x2013;solid nanophase change material (nanoPCM) composed of vanadium dioxide (VO<sub>2</sub>) and multiwalled carbon nanotubes (MWCNTs) was synthesized and incorporated into cement mortar at contents ranging from 0.5 to 3 wt%. The effects of nanoPCM incorporation on hydration behavior, microstructure, compressive strength, thermophysical properties (specific heat capacity, thermal conductivity, diffusivity and effusivity), thermal regulation capacity and energy saving were investigated. The results revealed a synergistic interaction between VO<sub>2</sub> and MWCNTs, reducing the phase transition temperature (Tc) from 72.41 &#xb0;C to 63.73 &#xb0;C while increasing thermal conductivity by approximately 3.5 times. The incorporation of nanoPCM slightly increased mortar density and improved long-term compressive strength, with a maximum increase of 24.5% observed at 1 wt% nanoPCM addition. Hydration calorimetry revealed that nanoPCM delayed early-age hydration kinetics without suppressing the overall hydration process. In the mortar composites, nanoPCM incorporation reduced thermal conductivity, diffusivity and effusivity with a slight decrease in the specific heat capacity, resulting in enhanced thermal inertia and delayed heat transfer. Thermal regulation tests confirmed a reduction in temperature fluctuations, while building energy simulations demonstrated annual energy savings of up to 2.23%, depending on climatic conditions. These findings demonstrate that tailoring the thermophysical properties of cementitious materials through VO<sub>2</sub>/MWCNT solid&#x2013;solid nanoPCM represents an effective strategy for improving passive indoor temperature regulation and reducing building energy demand without compromising mechanical performance.</p>
</abstract>
<kwd-group>
<kwd>building envelope</kwd>
<kwd>energy savings</kwd>
<kwd>microstructure</kwd>
<kwd>solid-solid phase transition</kwd>
<kwd>thermal properties</kwd>
</kwd-group>
<funding-group>
<funding-statement>The author(s) declared that financial support was not received for this work and/or its publication.</funding-statement>
</funding-group>
<counts>
<fig-count count="10"/>
<table-count count="5"/>
<equation-count count="3"/>
<ref-count count="36"/>
<page-count count="00"/>
</counts>
<custom-meta-group>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Structural Materials</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<label>1</label>
<title>Introduction</title>
<p>Improving the energy efficiency of buildings has become a global priority due to the increasing demand for energy and the need to reduce greenhouse gas emissions associated with the built environment (<xref ref-type="bibr" rid="B10">Hu et al., 2026</xref>). Consequently, the transition toward nearly zero-emission buildings has intensified the search for low-carbon construction materials capable of enhancing the thermal performance of building envelopes while reducing operational energy consumption. Passive thermal regulation strategies that reduce heat transfer through building envelopes have attracted considerable attention as an effective approach to decrease operational energy demand while improving building resilience and sustainability (<xref ref-type="bibr" rid="B9">Ghamari et al., 2024</xref>).</p>
<p>Among the different passive thermal-management technologies, phase change materials (PCMs) have emerged as promising candidates due to their ability to absorb, store and release thermal energy during phase transitions (<xref ref-type="bibr" rid="B29">Togun et al., 2025</xref>). The incorporation of PCMs into cementitious materials has been extensively investigated, demonstrating that PCM-modified cementitious composites can improve the thermal performance of building envelopes and contribute to energy savings under different climatic conditions (<xref ref-type="bibr" rid="B9">Ghamari et al., 2024</xref>; <xref ref-type="bibr" rid="B10">Hu et al., 2026</xref>). However, most investigations have focused on solid&#x2013;liquid phase transition PCMs which, despite their high latent heat storage capacity, often suffer from leakage during phase transition and therefore require encapsulation or shape-stabilization treatments prior to incorporation into construction materials (<xref ref-type="bibr" rid="B9">Ghamari et al., 2024</xref>; <xref ref-type="bibr" rid="B10">Hu et al., 2026</xref>).</p>
<p>Another important limitation of PCMs is their inherently low thermal conductivity, which restricts the rate of heat absorption and release during charging and discharging processes. This limitation can reduce the effective utilization of the stored thermal energy and slow the thermal response of PCM-based building materials. Furthermore, encapsulation and shape-stabilization strategies frequently introduce additional thermal resistance between the PCM and the surrounding cementitious matrix, reducing the efficiency of heat transfer toward active PCM domains (<xref ref-type="bibr" rid="B27">Su et al., 2015</xref>). As a result, relatively high PCM loadings, commonly exceeding 10 wt% in cementitious composites, are often required to achieve significant thermal-regulation effects and measurable reductions in building energy consumption (<xref ref-type="bibr" rid="B18">Liu et al., 2023</xref>; <xref ref-type="bibr" rid="B19">Lygerakis et al., 2025</xref>). To improve heat transfer efficiency carbon-based materials such as carbon nanotubes, graphene and other carbonaceous materials have been incorporated into PCMs, improving thermal and energy performance in cementitious materials (<xref ref-type="bibr" rid="B11">Jin et al., 2021</xref>; <xref ref-type="bibr" rid="B1">Aodkeng et al., 2022</xref>; <xref ref-type="bibr" rid="B35">Xiong et al., 2022</xref>; <xref ref-type="bibr" rid="B14">Kim et al., 2024</xref>). These studies demonstrated that carbon networks facilitate heat transfer toward active PCM domains. Nevertheless, these investigations have been almost exclusively focused on solid&#x2013;liquid PCMs, while the potential of carbon-enhanced solid&#x2013;solid PCM systems for cementitious applications remains largely unexplored.</p>
<p>Solid&#x2013;solid PCMs represent an attractive alternative for construction materials because they undergo phase transitions without liquid formation, thereby eliminating leakage problems while maintaining dimensional stability. Among them, VO<sub>2</sub> has attracted increasing interest owing to its reversible thermally induced phase transition and thermal energy storage capability (<xref ref-type="bibr" rid="B2">Baba et al., 2021</xref>). The incorporation of a VO<sub>2</sub>/MWCNT nanoPCM into gypsum composites has recently demonstrated promising potential for passive thermal regulation, highlighting the benefits of combining the thermal energy storage capability of VO<sub>2</sub> with the enhanced heat-transfer efficiency provided by MWCNTs (<xref ref-type="bibr" rid="B6">Figueroa-Torres et al., 2025</xref>). However, the study was focused on gypsum matrices containing 1 wt% of VO<sub>2</sub>/MWCNT and on demonstrating the feasibility of direct nanoPCM incorporation for thermoregulation. In contrast, the behavior of this VO<sub>2</sub>/MWCNT nanoPCM in Portland cement systems remains unexplored, despite the fundamental differences in hydration chemistry, microstructural evolution and strength development compared to gypsum. Moreover, the effects of VO<sub>2</sub>/MWCNT dosages exceeding 1 wt% on cement hydration kinetics, thermophysical properties and building energy performance have not yet been systematically investigated.</p>
<p>Therefore, this study investigates the incorporation of a VO<sub>2</sub>/MWCNT solid&#x2013;solid nanoPCM into cement mortar composites at dosages ranging from 0.5 to 3 wt%. Particular attention was given to evaluate how increasing VO<sub>2</sub>/MWCNT content influences cement hydration, microstructure, mechanical performance, thermophysical properties and thermal regulation capacity. Finally, the thermal performance of these nanoPCM-modified mortars was assessed through building energy simulations under different climatic conditions, considering their application as exterior cementitious coatings for energy-efficient buildings.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<label>2</label>
<title>Materials and methods</title>
<sec id="s2-1">
<label>2.1</label>
<title>Materials</title>
<p>In this study, Composite Portland Cement (CPC) 30R supplied by CEMEX, was used as the binder and standard &#x23;4 limestone sand was employed as fine aggregate. Vanadium dioxide (VO<sub>2</sub>) was acquired from Alfa Aesar&#x2122; with 99% purity. Hydroxyl functionalized MWCNTs (OH-MWCNTs) were purchased from US Research Nanomaterials, with an outer diameter of 20&#x2013;40 nm and lengths ranging from 10 to 30 &#x3bc;m, and a purity of 95%. Ethylene glycol (C<sub>2</sub>H<sub>6</sub>O<sub>2</sub>) with 99.91% of purity and distilled water were acquired from CTR Scientific. The mineralogical chemical composition of Portland cement is given in <xref ref-type="table" rid="T1">Table 1</xref>.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Chemical composition (wt%) of Portland cement CPC 30R.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">SiO<sub>2</sub>
</th>
<th align="center">Al<sub>2</sub>O<sub>3</sub>
</th>
<th align="center">CaO</th>
<th align="center">Fe<sub>2</sub>O<sub>3</sub>
</th>
<th align="center">MgO</th>
<th align="center">K<sub>2</sub>O</th>
<th align="center">TiO<sub>2</sub>
</th>
<th align="center">SO<sub>3</sub>
</th>
<th align="center">LOI<xref ref-type="table-fn" rid="Tfn1">
<sup>a</sup>
</xref>
</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">31.35</td>
<td align="center">3.92</td>
<td align="center">57.78</td>
<td align="center">2.49</td>
<td align="center">0.62</td>
<td align="center">0.97</td>
<td align="center">0.191</td>
<td align="center">2.36</td>
<td align="center">0.319</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="Tfn1">
<label>
<sup>a</sup>
</label>
<p>LOI: loss on ignition.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s2-2">
<label>2.2</label>
<title>Preparation of the nanophase change material</title>
<p>The nanophase change material VO<sub>2</sub>/MWCNT was synthesized using a wet impregnation method with a VO<sub>2</sub>-to-MWCNT mass ratio of 95:5, deliberately selected to maintain the heat storage capacity provided by VO<sub>2</sub> while enhancing the thermal conductivity of the system through the incorporation of MWCNTs. The required amounts of nanomaterials were first dispersed in isopropanol at a concentration of 10 mg/mL and sonicated in an ultrasonic bath for 1 h to promote homogeneous dispersion. Subsequently, isopropanol was slowly evaporated at 80 &#xb0;C under continuous magnetic stirring until a dry powder was obtained. The resulting nanocomposite was then thermally treated in air at 300 &#xb0;C for 2 h, using a heating rate of 10 &#xb0;C/min to eliminate residual isopropanol and enhance the interfacial contact between VO<sub>2</sub> nanoparticles and MWCNTs. Finally, the samples were cooled to room temperature.</p>
</sec>
<sec id="s2-3">
<label>2.3</label>
<title>NanoPCM-mortar composites preparation</title>
<p>Five rendering mortar composites were prepared, with one without VO<sub>2</sub>/MWCNT serving as the control sample and identified as REF. The other four were prepared by incorporating 0.5, 1, 2 and 3 wt% of the VO<sub>2</sub>/MWCNT nanoPCM relative to the cement mass. All mixtures were prepared using a fixed water-to-binder ratio of 0.74 to provide the workability required for rendering mortars, and a sand-to-binder ratio of 3:1. Ethylene glycol was used as a dispersing agent for the nanoPCM at a fixed dosage of 1 vol% of the mixing water.</p>
<p>To ensure adequate dispersion of the VO<sub>2</sub>/MWCNT nanoPCM, the required amount of nanoPCM and ethylene glycol was added to the mixing water and magnetically stirred for 10 min. Subsequently, the mixture was subjected to ultrasonication for 1 h. The resulting suspension was then used to prepare the mortars following ASTM C305. Fresh mortars were cast into cubic molds (50 &#xd7; 50 &#xd7; 50 mm) for compressive strength testing and cylindrical molds with a diameter of 2 cm for microstructural characterization. After casting, the samples were covered with plastic sheets to prevent water evaporation and stored at ambient temperature. After 24 h, the samples were demolded and cured under controlled conditions for 3, 7 and 28 days.</p>
</sec>
<sec id="s2-4">
<label>2.4</label>
<title>Characterization of the samples</title>
<p>The chemical composition of the CPC 30R cement was analyzed by X-ray fluorescence (XRF) using a PANalytical Epsilon 3-XL spectrometer operated under nitrogen atmosphere to avoid sample oxidation. The crystalline phases presented in the samples were determined by X-ray diffraction (XRD) using a PANalytical Empyrean diffractometer. The measurements were made using Cu K&#x3b1; radiation with a wavelength of 1.544 &#xc5;, in a 2&#x3b8; range from 5 &#xb0; to 65 &#xb0;, employing a step size of 0.02 &#xb0;. Microstructural observations were performed using Field Emission Scanning Electron Microscopy (FESEM) and vanadium elemental mapping was performed using EDS detector coupled to the microscope. Prior to analysis, samples were coated with a thin gold-palladium layer to improve surface conductivity due to the non-conductive nature of the cementitious samples.</p>
<p>The thermophysical properties of the VO<sub>2</sub> nanoparticles, MWCNTs and VO<sub>2</sub>/MWCNT nanoPCM were determined by differential scanning calorimetry (DSC) TA Instruments SCS Q200. Measurements were performed over a temperature range of 30 &#xb0;C&#x2013;100 &#xb0;C with a heating/cooling rate of 5 &#xb0;C/min under a nitrogen atmosphere. The phase transition temperature (Tc) was determined as the mean value of the endothermic and exothermic peaks during heating and cooling, respectively. The latent heats of the heating and cooling processes were obtained by integrating the corresponding DSC peak areas.</p>
<p>The effect of nanoPCM incorporation on the hydration kinetics of the mortar composites was investigated using isothermal calorimetry. Measurements were conducted with a Calmetrix I-Cal 4000 HPC isothermal conduction calorimeter at 23 &#xb0;C. Heat flow and cumulative heat release were continuously monitored and normalized to the mass of Portland cement.</p>
</sec>
<sec id="s2-5">
<label>2.5</label>
<title>Physical and mechanical characterization</title>
<p>The density of the mortar composites was determined according to ASTM C1329 by calculating the mass-to-volume ratio of the specimens. Prior to testing, the specimens were dried to constant mass under controlled conditions. The density values were obtained from the measured specimen mass and reported as the average of three measurements for each mixture.</p>
<p>The compressive strength of the mortar composites was determined according to ASTM C109. For this purpose, three specimens of each mixture were tested after 3, 7 and 28 days of curing. The specimens were subjected to uniaxial compressive loading until failure using an Instron 600DX hydraulic testing machine. The reported results correspond to the average compressive strength values and their corresponding standard deviations for each mixture.</p>
</sec>
<sec id="s2-6">
<label>2.6</label>
<title>Thermophysical characterization and thermal regulation performance</title>
<p>The thermophysical properties of the nanoPCM-mortar composites were evaluated by determining the thermal conductivity, specific heat capacity, thermal diffusivity and thermal effusivity. Thermal conductivity (k) was measured using a TEMPOS thermal properties analyzer (METER Group) equipped with an SH-3 sensor.</p>
<p>Because the mortar specimens contained a low concentration of dispersed nanoPCM in a heterogeneous cementitious matrix, conventional DSC measurements were not considered suitable, as the small specimen masses typically employed are not necessarily representative of the bulk composite (<xref ref-type="bibr" rid="B24">Pomianowski et al., 2014</xref>). Therefore, the specific heat capacity (Cp) was determined using a transient calorimetric method previously developed and validated for heterogeneous PCM-containing cementitious materials (<xref ref-type="bibr" rid="B24">Pomianowski et al., 2014</xref>), based on heat-flow measurements recorded during specimen cooling proposed for heat conduction calorimetry systems (<xref ref-type="bibr" rid="B17">Lehto et al., 1998</xref>). For this purpose, disk-shaped samples with dimensions of 25 mm in diameter and 10 mm in height were dried until reaching constant mass. The samples were heated from 25 &#xb0;C to 55 &#xb0;C until thermal equilibrium was achieved, which was monitored using a FLIR TG165 infrared thermometer with an emissivity value of 0.94. Subsequently, the heated specimens were placed inside the calorimeter and the heat flow signal was recorded until thermal equilibrium with the calorimeter was reached. The total thermal energy released during cooling (Ac) was obtained by integrating the heat-flow signal over time and was used to estimate the specific heat capacity according to <xref ref-type="disp-formula" rid="e1">Equation 1</xref>. All measurements were conducted under identical experimental conditions to allow comparative evaluation among mixtures.<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>p</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
</p>
<p>Where Ac is the total thermal energy released during cooling (J), T<sub>i</sub> is the initial temperature of the sample (&#xb0;C), T<sub>c</sub> is the calorimeter temperature, which was maintained at 23 &#xb0;C and P<sub>ms</sub> is the dry mass of the sample (kg).</p>
<p>The thermal diffusivity (&#x3b1;) and thermal effusivity (&#x3b5;) were calculated from the density (&#x3c1;), thermal conductivity and specific heat capacity values according to <xref ref-type="disp-formula" rid="e2">Equations 2</xref>, <xref ref-type="disp-formula" rid="e3">3</xref>, respectively (<xref ref-type="bibr" rid="B5">Errebai et al., 2021</xref>).<disp-formula id="e2">
<mml:math id="m2">
<mml:mrow>
<mml:mi mathvariant="normal">&#x3b1;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="normal">k</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="normal">&#x3c1;</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mo>&#x2a;</mml:mo>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mtext>Cp</mml:mtext>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>
<disp-formula id="e3">
<mml:math id="m3">
<mml:mrow>
<mml:mi mathvariant="normal">&#x3b5;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:mi mathvariant="normal">k</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mo>&#x2a;</mml:mo>
<mml:mtext>&#x2009;Cp&#x2009;</mml:mtext>
<mml:mo>&#x2a;</mml:mo>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi mathvariant="normal">&#x3c1;</mml:mi>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>
</p>
<p>The temperature regulation performance of nanoPCM-mortar composites was evaluated using a homemade insulated chamber, in which the internal temperature evolution of the samples was monitored under controlled heating and cooling conditions. Cubic samples (50 &#xd7; 50 &#xd7; 50 mm) were initially conditioned at ambient temperature. The chamber temperature was maintained at 40 &#xb0;C using a 250 W temperature-controlled infrared lamp positioned 35 cm above the samples. Prior to testing, the temperature inside the chamber was allowed to reach thermal equilibrium. A K-type thermocouple embedded at the center of each specimen was used to continuously monitor the internal temperature. The samples were exposed to the heating stage for 2 h, after which the infrared lamp was switched off, and the samples were allowed to cool naturally until reaching approximately 26 &#xb0;C. All thermal chamber experiments were performed in triplicate under identical experimental conditions, maintaining the same specimen position relative to the infrared lamp and the same thermocouple location within the specimens. The thermal regulation performance was assessed by comparing the temperature evolution and thermal response of mortars containing different VO<sub>2</sub>/MWCNT nanoPCM contents with that of the reference mortar. Similar experimental configurations have been successfully employed to evaluate the thermal regulation behavior of PCM-based cementitious materials (<xref ref-type="bibr" rid="B4">Du et al., 2020</xref>; <xref ref-type="bibr" rid="B21">Mohseni et al., 2020</xref>).</p>
</sec>
<sec id="s2-7">
<label>2.7</label>
<title>Energy efficiency of residential buildings using nanoPCM-mortar composites</title>
<p>Numerical simulations were conducted to investigate the energy efficiency of building envelopes incorporating nanoPCM-mortar composites. The simulations were performed using EnergyPlus 9.1, which is a widely used building energy modeling software. As illustrated in <xref ref-type="fig" rid="F1">Figure 1</xref>, a single-zone residential building with dimensions of 5.4 &#xd7; 6.0 &#xd7; 3.0 m was modeled to represent a typical housing unit. The building was assumed to be located on unobstructed flat terrain and free from shading effects caused by neighboring structures. The nanoPCM-mortar composites were incorporated as a 2.5 cm thick exterior rendering layer of the building envelope to investigate their influence on the overall thermal and energy performance of the house.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>
<bold>(a)</bold> Housing unit simulated in EnergyPlus. <bold>(b)</bold> Structure of the envelope walls.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g001.tif">
<alt-text content-type="machine-generated">Architectural drawing labeled a) shows a 5.4 m &#xd7; 6.0 m single house floor plan with two bedrooms, a bathroom, and a kitchen-living area, including detailed dimensions. Diagram labeled b) shows a wall cross-section composed of 2.5 centimeter NanoPCM-mortar composite, 15 centimeter concrete block, and 2.5 centimeter gypsum, indicating outside and indoor orientations.</alt-text>
</graphic>
</fig>
<p>The housing unit was evaluated under three representative climatic conditions in M&#xe9;xico: Monterrey (hot semi-arid climate, BSh), M&#xe9;xico City (temperate highland climate, Cwb) and Tem&#xf3;sachi (cold semi-arid climate, BSk) according to the K&#xf6;ppen&#x2013;Geiger climate classification. These locations were selected to represent contrasting climatic conditions commonly found in M&#xe9;xico. Weather files and hourly climatic data for each location were obtained from the Climate OneBuilding database (<xref ref-type="bibr" rid="B16">Lawrie and Crawley, 2022</xref>), which is based on the Integrated Surface Database (ISD) maintained by the U.S. National Oceanic and Atmospheric Administration (NOAA). The building geometry and wall configuration employed in the simulations are presented in <xref ref-type="fig" rid="F1">Figure 1</xref>.</p>
<p>Annual heating, cooling and total energy consumption were calculated, while indoor thermal comfort conditions were assessed using EnergyPlus, following a methodology similar to that reported by <xref ref-type="bibr" rid="B33">Wang et al. (2020)</xref>. The occupancy schedule considered two occupants with a standard working routine from 9:00 a.m. to 6:00 p.m., Monday through Friday, including weekends, public holidays and vacation periods. An air system was implemented to maintain indoor thermal comfort conditions, using heating and cooling set-point temperatures of 23 &#xb0;C and 25 &#xb0;C, respectively, in accordance with the thermal comfort ranges recommended by ASHRAE Standard 55. Heat transfer through the building envelope was modeled using the one-dimensional Conduction Finite-Difference (CondFD) algorithm available in EnergyPlus, which is particularly suitable for transient thermal simulations involving materials with temperature-dependent thermal behavior. The experimentally determined density, thermal conductivity and specific heat capacity of the mortar composites developed in this study were used as input parameters for the exterior rendering layer. All other building characteristics and simulation parameters were kept constant to isolate the effect of nanoPCM incorporation on the thermal and energy performance of the building envelope.</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<label>3</label>
<title>Results and discussion</title>
<sec id="s3-1">
<label>3.1</label>
<title>Characterization of VO<sub>2</sub>/MWCNT nanoPCM</title>
<p>
<xref ref-type="fig" rid="F2">Figure 2a</xref> presents the XRD diffractograms of the MWCNT, VO<sub>2</sub> nanoparticles and VO<sub>2</sub>/MWCNT nanoPCM with a 95:5 mass ratio. The MWCNTs exhibit characteristic diffraction peaks at 25.86 &#xb0;, 42.54 &#xb0;, 44.34 &#xb0; and 51.66 &#xb0;, associated with the (002), (100), (101) and (004) planes of the hexagonal graphite structure, in agreement with JCPDS card No. 058&#x2013;1638. The VO<sub>2</sub> nanoparticles presented sharp and well-defined diffraction peaks at 2&#x3b8; values of 26.88 &#xb0;, 27.72 &#xb0;, 33.35 &#xb0;, 37.01 &#xb0;, 39.62 &#xb0;, 42.23 &#xb0;, 55.41 &#xb0;, 57.51 &#xb0;, 64.91 &#xb0;, 70.37 &#xb0; and 72.06 &#xb0; which are indexed to the (110), (011), (<inline-formula id="inf1">
<mml:math id="m4">
<mml:mrow>
<mml:mover accent="true">
<mml:mn>2</mml:mn>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>11), (200), (020), (201), (220), (022), (031), (312) and (<inline-formula id="inf2">
<mml:math id="m5">
<mml:mrow>
<mml:mover accent="true">
<mml:mn>3</mml:mn>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>32) crystallographic planes of monoclinic phase (space group P2<sub>1</sub>/c), consistent with JCPDS card No. 00&#x2013;043&#x2013;1051. The diffraction pattern of the VO<sub>2</sub>/MWCNT is dominated by the characteristic reflections of VO<sub>2</sub> due to its high mass proportion in the composite. Notably, no additional diffraction peaks were detected, indicating the absence of secondary phases and that the synthesis process preserved the crystalline structure of both constituents. The exclusive presence of monoclinic VO<sub>2</sub> is particularly important because this polymorph undergoes the reversible thermally induced phase transition responsible for its phase change behavior (<xref ref-type="bibr" rid="B7">Fragoso-Fern&#xe1;ndez et al., 2022</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<bold>(a)</bold> XRD diffractograms and <bold>(b)</bold> morphology of VO<sub>2</sub>/MWCNT nanoPCM before the incorporation into the cement matrix.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g002.tif">
<alt-text content-type="machine-generated">Panel a presents an X-ray diffraction (XRD) pattern comparing VO&#x2082;, MWCNT, and VO&#x2082;/MWCNT composite, with characteristic peaks labeled for each material and intensity plotted against 2&#x3B8; degrees. Panel b shows a scanning electron microscope (SEM) image with multi-walled carbon nanotubes (MWCNT) clearly labeled by arrows among aggregated structures, accompanied by a 100 nanometer scale bar.</alt-text>
</graphic>
</fig>
<p>The morphology of the VO<sub>2</sub>/MWCNT is presented in <xref ref-type="fig" rid="F2">Figure 2b</xref>. VO<sub>2</sub> nanoparticles exhibited a nanoflake-like morphology with an average thickness of approximately 5 nm, while the MWCNTs displayed well-defined tubular structures with an average diameter of 30 nm. The nanotubes were distributed throughout the VO<sub>2</sub> nanoflake network and established multiple contact points between adjacent nanoflakes. The interconnected morphology is expected to facilitate heat transport within the nanoPCM and contribute to a more efficient heat distribution throughout the nanocomposite during heating and cooling.</p>
<p>
<xref ref-type="fig" rid="F3">Figure 3</xref> presents the DSC curves of the VO<sub>2</sub> nanoparticles, MWCNTs and VO<sub>2</sub>/MWCNT, while the corresponding thermal properties during heating and cooling are summarized in <xref ref-type="table" rid="T2">Table 2</xref>. As expected, the MWCNTs did not exhibit any thermal transitions, as evidenced by the absence of endothermic and exothermic signals throughout the evaluated temperature range. In contrast, the VO<sub>2</sub> nanoparticles exhibited distinct endothermic and exothermic peaks corresponding to the first-order solid&#x2013;solid phase change transition between the monoclinic to the rutile phase. The endothermic transition occurred at a transition temperature (Tc) of 72.41 &#xb0;C during heating, whereas the reverse transition during cooling was observed at 64.15 &#xb0;C. The latent heats associated with the heating and cooling processes were 40.51 Jg<sup>&#x2212;1</sup> and 32.84 Jg<sup>&#x2212;1</sup>, respectively.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>DSC curves of VO<sub>2</sub> nanoparticles, MWCNTs and VO<sub>2</sub>/MWCNT nanoPCM.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g003.tif">
<alt-text content-type="machine-generated">Differential scanning calorimetry graph displays heat flow in watts per gram versus temperature in degrees Celsius for MWCNT, VO&#x2082;, and 95VO&#x2082;/MWCNT samples, showing endothermic transitions and notable peaks labeled at 54.53, 63.73, 64.15, and 72.41 degrees Celsius for phase changes during heating and cooling cycles.</alt-text>
</graphic>
</fig>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Thermal properties of the nanoPCM materials.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Sample</th>
<th colspan="2" align="center">Heating cycle</th>
<th colspan="2" align="center">Cooling cycle</th>
<th rowspan="2" align="center">Thermal conductivity (W/m&#x22c5;K)</th>
</tr>
<tr>
<th align="center">Tc (&#xb0;C)</th>
<th align="center">&#x394;H (Jg<sup>-1</sup>)</th>
<th align="center">Tc (&#xb0;C)</th>
<th align="center">&#x394;H (Jg<sup>-1</sup>)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">VO<sub>2</sub>
</td>
<td align="center">72.41 &#xb1; 0.37</td>
<td align="center">40.51 &#xb1; 0.41</td>
<td align="center">64.15 &#xb1; 0.16</td>
<td align="center">32.84 &#xb1; 1.14</td>
<td align="center">0.049</td>
</tr>
<tr>
<td align="center">VO<sub>2</sub>/MWCNT</td>
<td align="center">63.73 &#xb1; 0.59</td>
<td align="center">38.06 &#xb1; 0.53</td>
<td align="center">54.53 &#xb1; 0.12</td>
<td align="center">29.76 &#xb1; 0.84</td>
<td align="center">0.17</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>For the VO<sub>2</sub>/MWCNT nanoPCM, a notable shift in phase transition behavior was observed. The endothermic peak appeared at 63.73 &#xb0;C, representing a reduction of 8.68 &#xb0;C compared with pure VO<sub>2</sub>, while the exothermic peak occurred at 54.53 &#xb0;C, corresponding to a reduction of 9.62 &#xb0;C during cooling. This decrease in Tc is advantageous because broadens the potential applicability of the nanoPCM under service conditions where higher surface temperatures can be reached, such as sun-exposed exterior building envelopes. The latent heat of the nanoPCM decreased slightly from 40.51 to 38.06 Jg<sup>&#x2212;1</sup> during heating and from 32.84 to 29.76 Jg<sup>&#x2212;1</sup> during cooling. Such reductions are expected because the incorporation of non-phase change active MWCNTs decreases the fraction of thermally active VO<sub>2</sub> within the nanocomposite. Nevertheless, the nanoPCM retained more than 90% of the latent heat storage capacity of pure VO<sub>2</sub> while exhibiting improved thermal transport properties.</p>
<p>Moreover, thermal conductivity measurements performed on partially compressed powder pellets revealed that the incorporation of MWCNTs increased the thermal conductivity from 0.049 to 0.17 W/m&#x22c5;K, corresponding to an enhancement of approximately 3.5 times. The enhanced thermal conductivity and reduced Tc can be attributed to the high intrinsic thermal conductivity of MWCNTs and their ability to establish conductive pathways throughout the PCM matrix, as evidenced by the interconnected morphology observed in the micrograph.</p>
</sec>
<sec id="s3-2">
<label>3.2</label>
<title>Physical and mechanical performance of nanoPCM-mortar composites</title>
<p>The density and compressive strength of the nanoPCM-mortar composites are presented in <xref ref-type="fig" rid="F4">Figure 4</xref>. All mortars exhibited densities within the typical range reported for conventional cement mortars (<xref ref-type="bibr" rid="B1">Aodkeng et al., 2022</xref>). The incorporation of VO<sub>2</sub>/MWCNT resulted in a slight but progressive increase in density, from 2,128 kg/m<sup>3</sup> for the reference mortar to 2,186 kg/m<sup>3</sup> for the mortar containing 3 wt% nanoPCM, corresponding to an increase of approximately 2.7%. The nanoscale dimension of the VO<sub>2</sub>/MWCNT particles may promote a filler effect by occupying the pores within the cementitious matrix, contributing to a denser microstructure.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Density and compressive strength development of nanoPCM-mortar composites with different VO<sub>2</sub>/MWCNT contents: <bold>(a)</bold> density and <bold>(b)</bold> compressive strength at 3, 7 and 28 days.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g004.tif">
<alt-text content-type="machine-generated">Bar chart with two panels compares density and compressive strength of samples containing different VO&#x2082;/MWCNT nanoPCM contents. Panel a shows density in kilograms per cubic meter, increasing from 2128.53 for the reference to 2186.46 at 3 weight percent. Panel b displays compressive strength in megapascals for 3, 7, and 28 days, with strength generally highest at 1 percent nanoPCM and after 28 days.</alt-text>
</graphic>
</fig>
<p>The effect of nanoPCM incorporation on compressive strength was dependent on both dosage and curing age. At 3 days, mortar composites containing 0.5 and 1 wt% nanoPCM exhibited compressive strengths of 11.63 and 12.81 MPa, respectively, compared with 10.48 MPa for the reference. However, further increases in nanoPCM content resulted in lower early-age strength, with values of 8.57 and 6.20 MPa for PCM-mortar composites containing 2 and 3 wt% of VO<sub>2</sub>/MWCNT, respectively. Similar trends were observed after 7 days of curing, although the differences between mixtures became less pronounced. At 28 days, all nanoPCM-mortar composites surpassed the reference mortar, indicating that the incorporation of the nanoPCM did not compromise long-term mechanical performance. The highest compressive strength was obtained for the mortar containing 1 wt% nanoPCM reaching 25.15 MPa, which corresponds to an increase of 24.5% compared with the reference. Mortars containing 2 and 3 wt% VO<sub>2</sub>/MWCNT also exhibited enhanced strengths with increases of 18.37% and 13.02%, respectively. These results indicate that increasing nanoPCM contents primarily affected early-age strength development, whereas the long-term mechanical performance was preserved or even improved.</p>
<p>The improvement in the compressive strength at low nanoPCM contents is consistent with the increase in density and can be associated with improved particle packing and matrix densification (<xref ref-type="bibr" rid="B34">Wang et al., 2025</xref>). The VO<sub>2</sub>/MWCNT nanoparticles may act as nano and microfillers, promoting a more compact cementitious matrix. Nevertheless, increasing the nanoPCM content beyond 1 wt% reduced the beneficial effect on compressive strength, although all nanoPCM-mortar composites still outperformed the reference mortar after 28 days. This behavior may be associated with the increasing difficulty of achieving homogeneous nanoparticle dispersion as the nanoPCM content increases. A recent review has highlighted that nanomaterials tend to agglomerate and re-agglomerate within cementitious systems, generating localized heterogeneities that can partially offset the beneficial effects associated with nanofiller incorporation and matrix densification (<xref ref-type="bibr" rid="B20">Mohammadi Ghahsareh et al., 2026</xref>). These results suggest that, although the incorporation of up to 3 wt% nanoPCM improved the long-term mechanical performance (28 days), the maximum mechanical response was achieved at 1 wt%, where the beneficial effects of particle packing and matrix densification prevailed over the adverse effects associated with nanoparticle agglomeration.</p>
</sec>
<sec id="s3-3">
<label>3.3</label>
<title>Hydration kinetics of VO<sub>2</sub>/MWCNT-modified cement pastes</title>
<p>
<xref ref-type="fig" rid="F5">Figure 5</xref> presents the effect of VO<sub>2</sub>/MWCNT nanoPCM incorporation on the hydration of cement. The incorporation of nanoPCM progressively modified the hydration process, as evidenced by the heat flow curves through the displacement of the main hydration peak toward longer hydration times and the reduction in the early-age heat evolution rate. This effect became more pronounced as the nanoPCM content increased, particularly for the nanoPCM-mortar composites containing 2 and 3 wt% of VO<sub>2</sub>/MWCNT. Nevertheless, the cumulative heat release curves revealed that hydration was not suppressed, since all mixtures eventually reached cumulative heat values comparable to or even higher than that of the reference after 14 days. The cumulative heat release was 6%, 5%, 9.4% and 12.5% higher than the reference for the mortars containing 0.5, 1, 2 and 3 wt% of VO<sub>2</sub>/MWCNT, respectively.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Hydration behavior of cement pastes containing different contents of VO<sub>2</sub>/MWCNT nanoPCM; Heat flow curves (solid lines) and cumulative heat (dash lines).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g005.tif">
<alt-text content-type="machine-generated">Line graph displaying heat flow in watts per gram and cumulative heat in joules per gram versus time in hours. Five dashed lines represent different sample compositions: REF, 0.5 wt%, 1 wt%, 2 wt%, and 3 wt%. Heat flow decreases rapidly for all samples within the first 100 hours, while cumulative heat increases steadily, with higher weight percent samples showing greater cumulative heat values.</alt-text>
</graphic>
</fig>
<p>The delayed hydration may be attributed, at least in part, to the presence of nanomaterials, which can modify the physicochemical environment of the cement hydration system, through surface adsorption, changes in ion transport and water distribution within the pore solution, thereby altering the nucleation and growth kinetics of hydration products (<xref ref-type="bibr" rid="B15">Land and Stephan, 2015</xref>; <xref ref-type="bibr" rid="B28">Tafesse and Kim, 2019</xref>). In addition, the thermal energy storage capability of the VO<sub>2</sub>/MWCNT nanoPCM may also contribute to the observed delay. Previous studies have shown that PCMs can effectively regulate hydration heat, while hydration temperatures exceeding 70 &#xb0;C have been reported during the early stages of cement hydration (<xref ref-type="bibr" rid="B13">Kim et al., 2015</xref>; <xref ref-type="bibr" rid="B12">Ju et al., 2024</xref>). Since the VO<sub>2</sub>/MWCNT nanoPCM exhibited a Tc of 63.73 &#xb0;C during heating, activation of the VO<sub>2</sub> solid-solid phase transition during hydration is physically possible. Under these conditions, part of the heat released by the exothermic hydration reactions may be temporarily absorbed through solid-solid phase transition of VO<sub>2</sub> before being gradually released as hydration progresses. The presence of MWCNT may further enhance this behavior by facilitating heat transfer toward the thermally active VO<sub>2</sub> domains, promoting a more efficient utilization of the nanoPCM. Similar synergistic role of carbon nanomaterials has recently been reported for PCM-modified cementitious systems (<xref ref-type="bibr" rid="B12">Ju et al., 2024</xref>). Accordingly, the progressively larger displacement of the main hydration peak with increasing VO<sub>2</sub>/MWCNT content suggests that higher nanoPCM additions provide greater thermal energy storage capacity during the early stages of hydration. The subsequent convergence of the cumulative heat release curves after approximately 150&#x2013;200 h indicates that hydration was delayed rather than suppressed. By the end of the monitoring period, the cumulative heat released by the nanoPCM-containing mixtures was comparable to or higher than that of the reference paste, indicating that hydration continued to progress despite the delayed early-age kinetics. A comparable hydration evolution has also been reported for PCM-modified cementitious systems, where delayed hydration was accompanied by higher cumulative heat release at later ages (<xref ref-type="bibr" rid="B13">Kim et al., 2015</xref>; <xref ref-type="bibr" rid="B23">Park and Choi, 2021</xref>; <xref ref-type="bibr" rid="B1">Aodkeng et al., 2022</xref>).</p>
<p>The hydration behavior is fully consistent with the compressive strength evolution of the nanoPCM-mortar composites. The delayed hydration kinetics primarily influenced early-age mechanical behavior, as mortars containing 2 and 3 wt% VO<sub>2</sub>/MWCNT exhibited lower compressive strengths at 3 and 7 days. However, as hydration progressed, all samples surpassed the reference after 28 days of curing. These observations indicate that the delayed hydration primarily affects early-age strength development, whereas the beneficial effects associated with nanoPCM incorporation become dominant at later curing ages.</p>
</sec>
<sec id="s3-4">
<label>3.4</label>
<title>Microstructure of nanoPCM-mortar composites</title>
<p>The XRD diffractograms of the hydrated pastes after 28 days of curing are shown in <xref ref-type="fig" rid="F6">Figure 6</xref>. All samples exhibited similar diffraction patterns dominated by the characteristic peaks of ettringite (PDF 00&#x2013;041&#x2013;1451), portlandite (PDF 00&#x2013;044&#x2013;1481) and calcite (PDF 00&#x2013;005&#x2013;0586), which are commonly observed hydration products in Portland cement systems.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>XRD diffractograms at 28 days of reference paste and pastes having different contents of VO<sub>2</sub>/MWCNT nanoPCM.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g006.tif">
<alt-text content-type="machine-generated">X-ray diffraction patterns compare five samples with increasing additive concentrations from REF (top, black), 0.5 wt% (red), 1 wt% (blue), 2 wt% (green), and 3 wt% (purple). Peaks are labeled for ettringite, portlandite, and calcite phases. Intensity is plotted against 2&#x3B8; angle ranging from 5 to 65 degrees.</alt-text>
</graphic>
</fig>
<p>No significant differences were observed in either the type or relative intensity of the crystalline hydration products as the nanoPCM content increased. Likewise, diffraction peaks associated with VO<sub>2</sub> or MWCNT were not detected. This can be attributed to the low nanoPCM content incorporated into the cement matrix (0.5&#x2013;3 wt%) and the predominance of the cement hydration products, whose diffraction signals largely overshadow those of the nanoPCM. These results indicate that no significant differences in the crystalline hydration products were detected after 28 days of curing with the incorporation of VO<sub>2</sub>/MWCNT. Combined with the calorimetry results, which revealed a delay in early hydration kinetics, these findings suggest that the nanoPCM primarily influences the rate of hydration at early ages, while the assemblage of crystalline hydration products at 28 days remains largely unchanged.</p>
<p>
<xref ref-type="fig" rid="F7">Figure 7</xref> presents the microstructural characterization of the nanoPCM-mortar composites. High-resolution SEM images revealed the presence of VO<sub>2</sub> nanoflakes interconnected by MWCNT bundles within the hydrated cement matrix. The characteristic morphology of both components remained identifiable after curing, indicating that the nanoPCM preserved its structural integrity during cement hydration. The micrographs also show that the VO<sub>2</sub>/MWCNT agglomerates were embedded within the hydrated matrix and occupied available spaces between hydration products. Furthermore, the MWCNT bundles appeared to form bridges between adjacent VO<sub>2</sub> nanoflakes, generating an interconnected microstructure similar to that observed before incorporation into the cementitious system. In some regions, MWCNTs appeared to extend across the void spaces between hydration products, potentially facilitating thermal transport between adjacent nanoPCM domains.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Microstructural characterization of the nanoPCM-mortar composites: <bold>(a,b)</bold> high-resolution SEM micrographs from different regions; <bold>(c)</bold> SEM image of the analyzed area and <bold>(d)</bold> vanadium elemental mapping.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g007.tif">
<alt-text content-type="machine-generated">Four-panel scientific figure showing electron microscope images. Panel a and b display nanostructures labeled with arrows indicating VO&#x2082; particles and multi-walled carbon nanotubes (MWCNTs) at 100 nanometer scale. Panel c shows a wider field view of aggregated nanomaterial at 2 micrometer scale. Panel d presents an elemental mapping image highlighting spatial distribution of vanadium with cyan coloration, also at 2 micrometer scale.</alt-text>
</graphic>
</fig>
<p>The elemental mapping of vanadium further confirmed the successful incorporation and distribution of the VO<sub>2</sub>/MWCNT. The vanadium signal was detected throughout the analyzed area. Although VO<sub>2</sub>-related diffraction peaks were not detected by XRD diffractograms, the mapping results demonstrate that the nanoPCM remained present within the matrix after curing. In addition, the presence of VO<sub>2</sub>/MWCNT within the microstructure is consistent with the slight increase in density and the compressive-strength improvements observed at moderate nanoPCM contents, while providing the nanoPCM domains responsible for the modified thermophysical behavior of the mortar composites.</p>
</sec>
<sec id="s3-5">
<label>3.5</label>
<title>Thermophysical properties and thermal regulation performance</title>
<p>The thermal conductivity was measured at six different mean temperatures, and the results are presented in <xref ref-type="fig" rid="F8">Figure 8</xref>. In general, the incorporation of the VO<sub>2</sub>/MWCNT nanoPCM progressively reduced the thermal conductivity of the mortar composites compared with the reference sample. At 25 &#xb0;C, the reference mortar exhibited a thermal conductivity of approximately 1.51 W/m&#x22c5;K, whereas the incorporation of 3 wt% nanoPCM decreased this value to 1.21 W/m&#x22c5;K, corresponding to a reduction of 19.86%. Although the incorporation of MWCNTs increased the thermal conductivity of the VO<sub>2</sub> from 0.049 to 0.17 W/m&#x22c5;K, the resulting VO<sub>2</sub>/MWCNT remained substantially less conductive than the reference mortar. Consequently, the overall thermal conductivity of the mortar composites decreased despite the conductive role of the MWCNTs within the nanoPCM, indicating that the effective thermal conductivity of the nanoPCM-mortar composite is governed by the combined influence of the cementitious matrix and its microstructural characteristics rather than solely by the intrinsic conductivity of the VO<sub>2</sub>/MWCNT. A comparable trend has been reported for n-octadecane PCM modified with activated carbon, graphene nanoplatelets, graphene or carbon nanotubes, where carbon nanomaterials enhanced heat transfer within the PCM phase while the overall cementitious composite retained a lower thermal conductivity than the reference material (<xref ref-type="bibr" rid="B14">Kim et al., 2024</xref>).</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Effect of VO<sub>2</sub>/MWCNT contents on the thermal conductivity as a function of temperature of the nanoPCM-mortar composites.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g008.tif">
<alt-text content-type="machine-generated">Line graph showing thermal conductivity in watts per meter-kelvin on the y-axis versus temperature in degrees Celsius on the x-axis for five sample groups: REF, 0.5 wt%, 1 wt%, 2 wt%, and 3 wt%. Each group is represented by a different colored symbol and line, with REF consistently showing the highest thermal conductivity, increasing steadily with temperature. 0.5 wt% displays the next highest conductivity, with 1 wt%, 2 wt%, and 3 wt% following in descending order. Error bars are present for each data point. Legend at the top differentiates groups by symbol and color.</alt-text>
</graphic>
</fig>
<p>Moreover, the reduction in thermal conductivity for the present mortar composites did not follow a linear trend with increasing nanoPCM content, suggesting that heat transport was also influenced by the distribution of the nanoPCM and its interaction with the cementitious matrix. Finally, all nanoPCM-mortar composites presented a slight increase in thermal conductivity with rising temperature but maintained lower thermal conductivity values than the reference sample throughout the evaluated temperature range.</p>
<p>
<xref ref-type="table" rid="T3">Table 3</xref> summarizes the measured specific heat capacity together with the calculated thermal diffusivity and effusivity of the nanoPCM-mortar composites at 25 &#xb0;C. The Cp of samples represents the amount of sensible heat required to increase the temperature of the material by one degree. As shown in <xref ref-type="table" rid="T3">Table 3</xref>, the incorporation of the VO<sub>2</sub>/MWCNT produced only a slight reduction in Cp from 862 J/kg&#x22c5;K for the reference mortar to 839 J/kg&#x22c5;K for the mortar containing 3 wt% VO<sub>2</sub>/MWCNT, corresponding to a reduction of &#x2248;2.7%. The measured specific heat capacity values are consistent with those reported for Portland cement mortars in the literature (<xref ref-type="bibr" rid="B25">Shafigh et al., 2020</xref>). This relatively small variation indicates that the improved thermal response of the nanoPCM-mortar composites cannot be explained by changes in Cp alone but should be interpreted together with the simultaneous reductions in thermal conductivity, thermal diffusivity, and thermal effusivity, which collectively govern transient heat transfer through the material.</p>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Specific heat capacity, thermal diffusivity, and thermal effusivity at 25 &#xb0;C.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">NanoPCM content (wt%)</th>
<th align="center">Specific heat capacity (J/kg&#x22c5;k)</th>
<th align="center">Diffusivity (&#x2a;10<sup>&#x2013;6</sup> m<sup>2</sup>/s)</th>
<th align="center">Effusivity (W&#x22c5;s<sup>1/2</sup>/m<sup>2</sup>&#x22c5;K)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">0</td>
<td align="center">862</td>
<td align="center">0.83</td>
<td align="center">1672.76</td>
</tr>
<tr>
<td align="center">0.5</td>
<td align="center">848</td>
<td align="center">0.76</td>
<td align="center">1581.81</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">845</td>
<td align="center">0.72</td>
<td align="center">1540.22</td>
</tr>
<tr>
<td align="center">2</td>
<td align="center">841</td>
<td align="center">0.68</td>
<td align="center">1520.74</td>
</tr>
<tr>
<td align="center">3</td>
<td align="center">839</td>
<td align="center">0.66</td>
<td align="center">1492.07</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Another important parameter for describing the thermal behavior of construction materials is thermal diffusivity, which represents the rate at which heat propagates through the material. Cement-based materials with lower thermal diffusivity exhibit a slower transient heat transfer response and are generally associated with greater thermal inertia, making them less susceptible to rapid temperature fluctuations (<xref ref-type="bibr" rid="B32">Verbeke and Audenaert, 2018</xref>). As shown in <xref ref-type="table" rid="T3">Table 3</xref>, the thermal diffusivity decreases progressively with increasing VO<sub>2</sub>/MWCNT content, from 0.83 &#xd7; 10<sup>&#x2212;6</sup> m<sup>2</sup>/s for the reference mortar to 0.66 &#xd7; 10<sup>&#x2212;6</sup> m<sup>2</sup>/s for the mortar containing 3 wt% nanoPCM, corresponding to a reduction of 20.48%. This reduction indicates that the incorporation of VO<sub>2</sub>/MWCNT slowed heat propagation through the mortar, thereby delaying the transmission of thermal disturbances across the material.</p>
<p>Moreover, thermal effusivity describes the ability of a material to absorb or release thermal energy through its surface with its surroundings upon contact, determining how rapidly the material responds to changes in surface temperature (<xref ref-type="bibr" rid="B3">Cottrill et al., 2018</xref>). Similar to thermal diffusivity, thermal effusivity decreased progressively with increasing VO<sub>2</sub>/MWCNT content, reaching a reduction of 10.8% for the mortar containing 3% nanoPCM compared with the reference mortar. Lower thermal effusivity values indicate a slower rate of heat exchange between the material and its surroundings, which may contribute to a more gradual thermal response and improved temperature buffering capacity.</p>
<p>The simultaneous reductions in specific heat capacity, thermal conductivity, diffusivity and effusivity demonstrate that the incorporation of the VO<sub>2</sub>/MWCNT modifies the transient heat transfer characteristics of the nanoPCM-mortar composites. The results indicate a slower heat transfer response, resulting in increased effective thermal inertia, enhanced attenuation of temperature fluctuations under transient thermal conditions and improved passive thermal regulation performance. Similar trends have been reported for cementitious materials containing phase change materials, where PCM incorporation led to reductions in thermal transport properties while improving thermal inertia and transient thermal performance (<xref ref-type="bibr" rid="B22">Olivieri et al., 2018</xref>; <xref ref-type="bibr" rid="B26">Shi et al., 2020</xref>; <xref ref-type="bibr" rid="B8">Gbekou et al., 2022</xref>).</p>
<p>The temperature regulation performance of the nanoPCM-mortar composites is presented in <xref ref-type="fig" rid="F9">Figure 9</xref> and summarized in <xref ref-type="table" rid="T4">Table 4</xref>. The internal temperature of the reference mortar increased progressively during heating until reaching approximately 40 &#xb0;C. In contrast, all nanoPCM-mortar composites exhibited a lower temperature rise throughout the heating stage. This effect became progressively more pronounced with increasing VO<sub>2</sub>/MWCNT content.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Temperature evolution at the center of the samples during the thermal regulation test conducted at 40 &#xb0;C.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g009.tif">
<alt-text content-type="machine-generated">Four-panel graphic shows temperature versus time data for heating and cooling cycles at different concentrations: 0.5 wt% (red, top left), 1 wt% (blue, top right), 2 wt% (green, bottom left), and 3 wt% (purple, bottom right). Each panel has a shaded region for heating up to around 2 hours, followed by cooling, displaying similar curve shapes peaking near 40&#xB0;C before decreasing, with concentration indicated in each plot.</alt-text>
</graphic>
</fig>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Regulation performance of nanoPCM-mortar composites.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">NanoPCM content (wt%)</th>
<th align="center">Temperature at REF T<sub>max</sub> (&#xb0;C)</th>
<th align="center">&#x394;T vs. REF (&#xb0;C)</th>
<th align="center">Delay time to T<sub>max</sub> (min)</th>
<th align="center">Final temperature after cooling (&#xb0;C)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">REF</td>
<td align="center">40 &#xb1; 0.3</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">26 &#xb1; 0.2</td>
</tr>
<tr>
<td align="center">0.5</td>
<td align="center">39.8 &#xb1; 0.3</td>
<td align="center">0.2</td>
<td align="center">1 &#xb1; 0.5</td>
<td align="center">25.8 &#xb1; 0.1</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">39.5 &#xb1; 0.2</td>
<td align="center">0.5</td>
<td align="center">12 &#xb1; 0.7</td>
<td align="center">25.7 &#xb1; 0.2</td>
</tr>
<tr>
<td align="center">2</td>
<td align="center">39.1 &#xb1; 0.1</td>
<td align="center">0.9</td>
<td align="center">18 &#xb1; 0.5</td>
<td align="center">25.7 &#xb1; 0.3</td>
</tr>
<tr>
<td align="center">3</td>
<td align="center">38.9 &#xb1; 0.3</td>
<td align="center">1.1</td>
<td align="center">21 &#xb1; 0.4</td>
<td align="center">25.6 &#xb1; 0.3</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>When the reference mortar reached 40 &#xb0;C after approximately 1.5 h of heating, the mortars containing VO<sub>2</sub>/MWCNT exhibited temperatures ranging from 39.8 &#xb0;C for the mortar with 0.5 wt%&#x2013;38.9 &#xb0;C for the mortar with 3 wt%. These values correspond to temperature reductions between 0.2 &#xb0;C and 1.1 &#xb0;C relative to the reference mortar. Although the mortar containing 0.5 wt% VO<sub>2</sub>/MWCNT exhibited only a slight reduction in peak temperature, progressively larger temperature reductions and thermal delays were observed as the nanoPCM content increased. As shown in <xref ref-type="table" rid="T4">Table 4</xref>, the time lag increased from 1 min for the mortar containing 0.5 wt% VO<sub>2</sub>/MWCNT to 21 min for the mortar containing 3 wt% VO<sub>2</sub>/MWCNT. The enhancement in thermal regulation became evident at nanoPCM contents of 2 wt% and above, where the reduction in peak temperatures and the delay in heat propagation were more pronounced. The combination of lower internal temperatures and delayed temperature peaks demonstrate that the incorporation of VO<sub>2</sub>/MWCNT effectively modified the transient thermal response of the mortar composites during heating. Considering that the maximum temperature reached during the test remained below the Tc of VO<sub>2</sub>, this behavior cannot be attributed to latent heat storage. Instead, it is consistent with the reduced thermal conductivity, diffusivity and effusivity of the nanoPCM-mortar composites, which slowed heat transfer through the cementitious matrix and increased its effective thermal inertia.</p>
<p>During the cooling stage, all mixtures exhibited similar temperature profiles and reached thermal equilibrium within a comparable period. The nanoPCM-mortar composites attained 26 &#xb0;C slightly earlier than the reference mortar, which can be attributed to the lower peak temperatures reached during the heating period. Therefore, the main benefit of incorporation VO<sub>2</sub>/MWCNT under the evaluated conditions was observed during the heating stage, where slower heat propagation delayed the temperature rise and reduced the maximum temperature reached by the PCM-mortar composites.</p>
<p>These results demonstrated that incorporation VO<sub>2</sub>/MWCNT improves the transient thermal behavior of cementitious mortars by reducing heat transfer rates and enhancing their thermal buffering capacity. Although the phase transition temperature of the VO<sub>2</sub> was not reached under the present experimental conditions, the modified thermophysical properties of the nanoPCM-mortar composites were sufficient to attenuate temperature fluctuations during heating. These observations are consistent with previous studies reporting that improvements in the thermophysical properties and thermal inertia of PCM-modified cementitious materials contribute to enhanced thermal performance of building envelopes (<xref ref-type="bibr" rid="B36">Yang et al., 2022</xref>; <xref ref-type="bibr" rid="B30">Tripathi and Shukla, 2024</xref>; <xref ref-type="bibr" rid="B31">Vedrtnam et al., 2025</xref>).</p>
</sec>
<sec id="s3-6">
<label>3.6</label>
<title>Energy efficiency simulation results</title>
<p>
<xref ref-type="table" rid="T5">Table 5</xref> summarizes the annual heating, cooling and total energy demands obtained from the EnergyPlus simulations for the three climatic conditions considered. In all cases, the incorporation of VO<sub>2</sub>/MWCNT nanoPCM reduced the annual building energy consumption compared with the reference mortar. Furthermore, the energy-saving effect increased progressively with nanoPCM content, with the mortar containing 3 wt% nanoPCM exhibiting the best overall performance under all climatic conditions.</p>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Annual heating, cooling and total energy consumption of buildings incorporating nanoPCM-mortar composite as exterior coatings.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">City/Climate</th>
<th align="center">NanoPCM content (wt%)</th>
<th align="center">Heating (kWh/m<sup>2</sup>&#x22c5;year)</th>
<th align="center">Cooling (kWh/m<sup>2</sup>&#x22c5;year)</th>
<th align="center">Total (kWh/m<sup>2</sup>&#x22c5;year)</th>
<th align="center">Energy savings (%)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="5" align="center">Monterrey (hot semi-arid)</td>
<td align="center">REF</td>
<td align="center">77.7</td>
<td align="center">213.2</td>
<td align="center">290.9</td>
<td align="center">&#x2013;</td>
</tr>
<tr>
<td align="center">0.5</td>
<td align="center">77.2</td>
<td align="center">212.5</td>
<td align="center">289.6</td>
<td align="center">0.45</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">76.9</td>
<td align="center">212.1</td>
<td align="center">289.0</td>
<td align="center">0.66</td>
</tr>
<tr>
<td align="center">2</td>
<td align="center">76.8</td>
<td align="center">211.9</td>
<td align="center">288.7</td>
<td align="center">0.78</td>
</tr>
<tr>
<td align="center">3</td>
<td align="center">76.6</td>
<td align="center">211.6</td>
<td align="center">288.2</td>
<td align="center">0.95</td>
</tr>
<tr>
<td rowspan="5" align="center">Tem&#xf3;sachi (cold semi-arid)</td>
<td align="center">REF</td>
<td align="center">262.0</td>
<td align="center">50.7</td>
<td align="center">312.7</td>
<td align="center">&#x2013;</td>
</tr>
<tr>
<td align="center">0.5</td>
<td align="center">261.7</td>
<td align="center">50.6</td>
<td align="center">312.3</td>
<td align="center">0.13</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">259.6</td>
<td align="center">50.1</td>
<td align="center">309.7</td>
<td align="center">0.94</td>
</tr>
<tr>
<td align="center">2</td>
<td align="center">259.2</td>
<td align="center">50.0</td>
<td align="center">309.2</td>
<td align="center">1.11</td>
</tr>
<tr>
<td align="center">3</td>
<td align="center">258.6</td>
<td align="center">49.8</td>
<td align="center">308.5</td>
<td align="center">1.35</td>
</tr>
<tr>
<td rowspan="5" align="center">M&#xe9;xico city (temperate highland)</td>
<td align="center">REF</td>
<td align="center">145.7</td>
<td align="center">44.0</td>
<td align="center">189.7</td>
<td align="center">&#x2013;</td>
</tr>
<tr>
<td align="center">0.5</td>
<td align="center">144.0</td>
<td align="center">43.7</td>
<td align="center">187.6</td>
<td align="center">1.10</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">143.2</td>
<td align="center">43.5</td>
<td align="center">186.7</td>
<td align="center">1.57</td>
</tr>
<tr>
<td align="center">2</td>
<td align="center">142.9</td>
<td align="center">43.4</td>
<td align="center">186.2</td>
<td align="center">1.84</td>
</tr>
<tr>
<td align="center">3</td>
<td align="center">142.2</td>
<td align="center">43.2</td>
<td align="center">185.5</td>
<td align="center">2.23</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The highest reduction in annual energy consumption was achieved in M&#xe9;xico City, where the incorporation of 3 wt% nanoPCM decreased the total energy demand from 189.7 to 185.5 kWh/m<sup>2</sup>&#xb7;year, corresponding to a saving of 2.23%. Lower but still measurable reductions were observed in Tem&#xf3;sachi and Monterrey, where maximum savings of 1.35% and 0.95%, respectively, were obtained.</p>
<p>To better visualize the influence of nanoPCM dosage, the annual energy savings relative to the reference mortar are presented in <xref ref-type="fig" rid="F10">Figure 10</xref>. The improved energy performance can be attributed to the thermophysical modifications induced by the incorporation of the VO<sub>2</sub>/MWCNT into the mortar. Experimental measurements showed that nanoPCM addition reduced the thermal conductivity, diffusivity and effusivity of the nanoPCM-mortar composites, while only slightly affecting their specific heat capacity. Collectively, these changes slowed transient heat transfer through the building envelope and consequently reduced the energy required to maintain thermal comfort conditions.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Annual energy savings relative to the reference mortar as a function of nanoPCM content for three Mexican climates.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmats-13-1906993-g010.tif">
<alt-text content-type="machine-generated">Line chart depicts annual energy saving percentage versus VO&#x2082;/MWCNT nanoPCM content in weight percent for Monterrey, Tem&#xF3;sachi, and M&#xE9;xico City. M&#xE9;xico City shows the highest energy savings at each data point, reaching 2.23% at 3 wt%.</alt-text>
</graphic>
</fig>
<p>These results highlight the potential of VO<sub>2</sub>/MWCNT nanoPCM-mortar composites as a practical strategy for improving the thermal performance of building envelopes without requiring high PCM loadings or major modifications to conventional construction systems. Similar trends have been reported in previous studies. L. Zhuo et al. investigated cementitious materials incorporating a solid&#x2013;gel phase change material and observed that increasing the PCM content from 10 to 30 vol% reduced annual cooling-energy consumption by 0.89%&#x2013;4.43%, while the corresponding reduction in heating demand remained below 0.4% (<xref ref-type="bibr" rid="B18">Liu et al., 2023</xref>). Likewise, F. Lygerakis et al. reported net annual energy savings of 2.6% in a Mediterranean climate using cement boards containing 10 wt% of a shape-stabilized n-octadecane PCM, a conventional solid&#x2013;liquid PCM system. Increasing the PCM content to 30 wt% was required to achieve a maximum saving of 4.8% (<xref ref-type="bibr" rid="B19">Lygerakis et al., 2025</xref>). In comparison, the present study achieved annual energy savings of up to 2.23% using only 3 wt% of VO<sub>2</sub>/MWCNT incorporated into a 2.5 cm thick exterior mortar coating. Although the absolute savings were moderate, they were achieved with substantially lower nanoPCM content than those commonly reported for cementitious PCM systems. These results indicate that improving the thermophysical properties and transient heat transfer characteristics of cementitious materials can contribute to measurable reductions in building energy demand without requiring high PCM loading or major modifications to conventional construction systems. Therefore, optimizing the thermophysical properties of cementitious composites, together with facilitating heat transport within the nanoPCM through conductive nanostructures such as MWCNTs, represents an effective strategy for enhancing the thermal performance of building envelopes while minimizing nanoPCM incorporation.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<label>4</label>
<title>Conclusion</title>
<p>The VO<sub>2</sub>/MWCNT nanoPCM was successfully synthesized and incorporated into cement mortar, producing multifunctional mortar composites with improved thermophysical performance and thermoregulatory capability. The main findings of this study are summarized as follows:<list list-type="bullet">
<list-item>
<p>The developed VO<sub>2</sub>/MWCNT nanoPCM exhibited synergistic thermal characteristics. The incorporation of MWCNTs reduced the phase transition temperature from 72.41 &#xb0;C to 63.73 &#xb0;C, increased thermal conductivity by approximately 3.5 times, while preserving more than 90% of the latent heat storage capacity of the pristine VO<sub>2</sub>.</p>
</list-item>
<list-item>
<p>The incorporation of the VO<sub>2</sub>/MWCNT delayed the early-age hydration kinetics of cement pastes without suppressing the overall hydration process, likely associated with physicochemical interactions induced by the nanoPCM, together with the possible contribution of thermal energy storage under the localized temperatures generated during cement hydration.</p>
</list-item>
<list-item>
<p>NanoPCM-mortar composites presented multifunctional performance, including slight increases in density and long-term compressive strength, together with reduced thermal conductivity, thermal diffusivity, thermal effusivity and specific heat capacity. Collectively, these modifications increased the effective thermal inertia of the mortar composites, slowed transient heat transfer and enhanced their thermoregulatory performance without compromising mechanical properties. Under the evaluated conditions, these improvements became more evident at VO<sub>2</sub>/MWCNT contents of 2 wt% and above, suggesting that sufficient nanoPCM incorporation is necessary to achieve measurable thermoregulatory benefits in Portland cement mortars.</p>
</list-item>
<list-item>
<p>Building energy simulations demonstrated that the thermophysical modifications induced by the nanoPCM translated into measurable reductions in annual energy demand when the developed mortar was applied as an exterior rendering. The highest energy saving (2.23%) was achieved under temperate highland climatic conditions, indicating that the energy performance of the proposed exterior rendering is climate dependent. These results demonstrate that tailoring the thermophysical properties of cementitious composites, together with the enhanced heat transport within the nanoPCM provided by the conductive MWCNT network, represents an effective strategy for improving the thermal performance of building envelopes while minimizing nanoPCM incorporation.</p>
</list-item>
</list>
</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec sec-type="author-contributions" id="s6">
<title>Author contributions</title>
<p>JV-M: Writing &#x2013; original draft, Investigation, Software. CF-F: Formal Analysis, Validation, Writing &#x2013; review and editing. JG-L: Writing &#x2013; review and editing, Supervision. MG-C: Supervision, Writing &#x2013; review and editing. MF-T: Conceptualization, Methodology, Supervision, Writing &#x2013; original draft.</p>
</sec>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s9">
<title>Generative AI statement</title>
<p>The author(s) declared that generative AI was used in the creation of this manuscript. An AI assistant was utilized during the drafting process of this manuscript solely for English language translation, grammatical refinement, and technical prose styling to ensure clarity. All core scientific methodologies, data generation, analysis, interpretation, and conclusions were independently conceptualized and executed entirely by the human authors.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aodkeng</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Sinthupinyo</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Chamnankid</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Hanpongpun</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Chaipanich</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Effect of carbon nanotubes/clay hybrid composite on mechanical properties, hydration heat and thermal analysis of cement-based materials</article-title>. <source>Constr. Build. Mater.</source> <volume>320</volume>, <fpage>126212</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2021.126212</pub-id>
</mixed-citation>
</ref>
<ref id="B2">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baba</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Nemoto</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Otaki</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Sasaki</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Takeda</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Yamada</surname>
<given-names>N.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Temperature leveling of electronic chips by solid-solid phase change materials compared to solid-liquid phase change materials</article-title>. <source>Int. J. Heat. Mass Transf.</source> <volume>179</volume>, <fpage>121731</fpage>. <pub-id pub-id-type="doi">10.1016/j.ijheatmasstransfer.2021.121731</pub-id>
</mixed-citation>
</ref>
<ref id="B3">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cottrill</surname>
<given-names>A. L.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>A. T.</given-names>
</name>
<name>
<surname>Kunai</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Koman</surname>
<given-names>V. B.</given-names>
</name>
<name>
<surname>Kaplan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Mahajan</surname>
<given-names>S. G.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Ultra-high thermal effusivity materials for resonant ambient thermal energy harvesting</article-title>. <source>Nat. Commun.</source> <volume>9</volume>, <fpage>664</fpage>. <pub-id pub-id-type="doi">10.1038/s41467-018-03029-x</pub-id>
<pub-id pub-id-type="pmid">29445195</pub-id>
</mixed-citation>
</ref>
<ref id="B4">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Du</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Quan</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Characterization and cooling effect of a novel cement-based composite phase change material</article-title>. <source>Sol. Energy</source> <volume>208</volume>, <fpage>573</fpage>&#x2013;<lpage>582</lpage>. <pub-id pub-id-type="doi">10.1016/j.solener.2020.07.083</pub-id>
</mixed-citation>
</ref>
<ref id="B5">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Errebai</surname>
<given-names>F. B.</given-names>
</name>
<name>
<surname>Chikh</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Derradji</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Amara</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Younsi</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Optimum mass percentage of microencapsulated PCM mixed with gypsum for improved latent heat storage</article-title>. <source>J. Energy Storage</source> <volume>33</volume>, <fpage>101910</fpage>. <pub-id pub-id-type="doi">10.1016/j.est.2020.101910</pub-id>
</mixed-citation>
</ref>
<ref id="B6">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Figueroa-Torres</surname>
<given-names>M. Z.</given-names>
</name>
<name>
<surname>Gonz&#xe1;lez-L&#xf3;pez</surname>
<given-names>J. R.</given-names>
</name>
<name>
<surname>Guerra-Cossio</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Gonz&#xe1;lez-Ju&#xe1;rez</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Alonso-Lemus</surname>
<given-names>I. L.</given-names>
</name>
<name>
<surname>Fragoso-Fern&#xe1;ndez</surname>
<given-names>C. Y.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Novel VO2/MWCNT nanophase change material composite incorporated into gypsum for indoor thermoregulation in buildings</article-title>. <source>Constr. Build. Mater.</source> <volume>492</volume>, <fpage>142825</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2025.142825</pub-id>
</mixed-citation>
</ref>
<ref id="B7">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fragoso-Fern&#xe1;ndez</surname>
<given-names>C. Y.</given-names>
</name>
<name>
<surname>Gonz&#xe1;lez-L&#xf3;pez</surname>
<given-names>J. R.</given-names>
</name>
<name>
<surname>Guerra-Coss&#xed;o</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Toxqui-Ter&#xe1;n</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Zald&#xed;var-Cadena</surname>
<given-names>A. A.</given-names>
</name>
<name>
<surname>Figueroa-Torres</surname>
<given-names>M. Z.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Study on thermally stabilized vanadium dioxide nanoparticles solid&#x2013;solid phase change thermal energy storage material</article-title>. <source>J. Mater. Sci. Mater. Electron.</source> <volume>33</volume>, <fpage>26580</fpage>&#x2013;<lpage>26589</lpage>. <pub-id pub-id-type="doi">10.1007/s10854-022-09334-y</pub-id>
</mixed-citation>
</ref>
<ref id="B8">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gbekou</surname>
<given-names>F. K.</given-names>
</name>
<name>
<surname>Benzarti</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Boudenne</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Eddhahak</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Duc</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Mechanical and thermophysical properties of cement mortars including bio-based microencapsulated phase change materials</article-title>. <source>Constr. Build. Mater.</source> <volume>352</volume>, <fpage>129056</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2022.129056</pub-id>
</mixed-citation>
</ref>
<ref id="B9">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ghamari</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>See</surname>
<given-names>C. H.</given-names>
</name>
<name>
<surname>Hughes</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Mallick</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Reddy</surname>
<given-names>K. S.</given-names>
</name>
<name>
<surname>Patchigolla</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Advancing sustainable building through passive cooling with phase change materials, a comprehensive literature review</article-title>. <source>Energy Build.</source> <volume>312</volume>, <fpage>114164</fpage>. <pub-id pub-id-type="doi">10.1016/j.enbuild.2024.114164</pub-id>
</mixed-citation>
</ref>
<ref id="B10">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Duan</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2026</year>). <article-title>Thermal energy &#x201c;shifting&#x201d; and spatial regulation: a review of the design and application of thermal storage composite cementitious material</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>238</volume>, <fpage>117064</fpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2026.117064</pub-id>
</mixed-citation>
</ref>
<ref id="B11">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jin</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Gu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Preparation and characterization of capric-stearic acid/montmorillonite/graphene composite phase change material for thermal energy storage in buildings</article-title>. <source>Constr. Build. Mater.</source> <volume>301</volume>, <fpage>124102</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2021.124102</pub-id>
</mixed-citation>
</ref>
<ref id="B12">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ju</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>A novel thermal-tailored strategy to mitigate thermal cracking of cement-based materials by carbon fibers and liquid-metal-based microencapsulated phase change materials</article-title>. <source>Constr. Build. Mater.</source> <volume>428</volume>, <fpage>136338</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2024.136338</pub-id>
</mixed-citation>
</ref>
<ref id="B13">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>Y.-R.</given-names>
</name>
<name>
<surname>Khil</surname>
<given-names>B.-S.</given-names>
</name>
<name>
<surname>Jang</surname>
<given-names>S.-J.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>W.-C.</given-names>
</name>
<name>
<surname>Yun</surname>
<given-names>H.-D.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Effect of barium-based phase change material (PCM) to control the heat of hydration on the mechanical properties of mass concrete</article-title>. <source>Thermochim. Acta</source> <volume>613</volume>, <fpage>100</fpage>&#x2013;<lpage>107</lpage>. <pub-id pub-id-type="doi">10.1016/j.tca.2015.05.025</pub-id>
</mixed-citation>
</ref>
<ref id="B14">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>Y. U.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Thermal characteristics of cementitious building materials with carbon and PCM for improved heat storage performance</article-title>. <source>Constr. Build. Mater.</source> <volume>449</volume>, <fpage>138550</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2024.138550</pub-id>
</mixed-citation>
</ref>
<ref id="B15">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Land</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Stephan</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Controlling cement hydration with nanoparticles</article-title>. <source>Cem. Concr. Compos.</source> <volume>57</volume>, <fpage>64</fpage>&#x2013;<lpage>67</lpage>. <pub-id pub-id-type="doi">10.1016/j.cemconcomp.2014.12.003</pub-id>
</mixed-citation>
</ref>
<ref id="B16">
<mixed-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Lawrie</surname>
<given-names>L. K.</given-names>
</name>
<name>
<surname>Crawley</surname>
<given-names>D. B.</given-names>
</name>
</person-group> (<year>2022</year>). <source>Development of Global Typical Meteorological Year (TMYx) and Typical Design Day Data for Building Energy Simulation</source>. <comment>Available online at: <ext-link ext-link-type="uri" xlink:href="https://climate.onebuilding.org">https://climate.onebuilding.org</ext-link> (Accessed May 17, 2026).</comment>
</mixed-citation>
</ref>
<ref id="B17">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lehto</surname>
<given-names>V.-P.</given-names>
</name>
<name>
<surname>Rahkola</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Laine</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Ylianttila</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Hyssalo</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Jokela</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>1998</year>). <article-title>Determination of specific heats using isothermal microcalorimetry</article-title>. <source>J. Therm. Anal. Calorim.</source> <volume>53</volume>, <fpage>685</fpage>&#x2013;<lpage>695</lpage>. <pub-id pub-id-type="doi">10.1023/A:1010166005911</pub-id>
</mixed-citation>
</ref>
<ref id="B18">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Du</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Steere</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Schlegel</surname>
<given-names>J. P.</given-names>
</name>
<name>
<surname>Khayat</surname>
<given-names>K. H.</given-names>
</name>
<name>
<surname>Weina</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Cement-based materials with solid&#x2013;gel phase change materials for improving energy efficiency of building envelope</article-title>. <source>J. Mater. Civ. Eng.</source> <volume>35</volume>, <fpage>4023425</fpage>. <pub-id pub-id-type="doi">10.1061/JMCEE7.MTENG-15925</pub-id>
</mixed-citation>
</ref>
<ref id="B19">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lygerakis</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Gioti</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Karakassides</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Gournis</surname>
<given-names>D. P.</given-names>
</name>
<name>
<surname>Yentekakis</surname>
<given-names>I. V.</given-names>
</name>
<name>
<surname>Kolokotsa</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Impact of accelerated weather aging on building energy efficiency using cement and gypsum boards with shape-stabilized phase change materials</article-title>. <source>Sci. Rep.</source> <volume>15</volume>, <fpage>40884</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-025-24728-8</pub-id>
</mixed-citation>
</ref>
<ref id="B20">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mohammadi Ghahsareh</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Jaha</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Bao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Khayat</surname>
<given-names>K. H.</given-names>
</name>
<name>
<surname>Meng</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2026</year>). <article-title>Advances and challenges in nano-modified cementitious composites: mechanisms, dispersion strategies, and impact on mechanical properties</article-title>. <source>J. Build. Eng.</source> <volume>119</volume>, <fpage>115138</fpage>. <pub-id pub-id-type="doi">10.1016/j.jobe.2025.115138</pub-id>
</mixed-citation>
</ref>
<ref id="B21">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mohseni</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Tang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Khayat</surname>
<given-names>K. H.</given-names>
</name>
<name>
<surname>Cui</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Thermal performance and corrosion resistance of structural-functional concrete made with inorganic PCM</article-title>. <source>Constr. Build. Mater.</source> <volume>249</volume>, <fpage>118768</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2020.118768</pub-id>
</mixed-citation>
</ref>
<ref id="B22">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Olivieri</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Tenorio</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Revuelta</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Navarro</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Cabeza</surname>
<given-names>L. F.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Developing a PCM-enhanced mortar for thermally active precast walls</article-title>. <source>Constr. Build. Mater.</source> <volume>181</volume>, <fpage>638</fpage>&#x2013;<lpage>649</lpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2018.06.013</pub-id>
</mixed-citation>
</ref>
<ref id="B23">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Park</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>Y. C.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Investigating the effect of CNTs on early age hydration and autogenous shrinkage of cement composite</article-title>. <source>Appl. Sci.</source> <volume>11</volume>, <fpage>5545</fpage>. <pub-id pub-id-type="doi">10.3390/app11125545</pub-id>
</mixed-citation>
</ref>
<ref id="B24">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pomianowski</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Heiselberg</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Jensen</surname>
<given-names>R. L.</given-names>
</name>
<name>
<surname>Cheng</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>A new experimental method to determine specific heat capacity of inhomogeneous concrete material with incorporated microencapsulated-PCM</article-title>. <source>Cem. Concr. Res.</source> <volume>55</volume>, <fpage>22</fpage>&#x2013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1016/j.cemconres.2013.09.012</pub-id>
</mixed-citation>
</ref>
<ref id="B25">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shafigh</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Asadi</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Akhiani</surname>
<given-names>A. R.</given-names>
</name>
<name>
<surname>Mahyuddin</surname>
<given-names>N. B.</given-names>
</name>
<name>
<surname>Hashemi</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Thermal properties of cement mortar with different mix proportions</article-title>. <source>Mater. Constr.</source> <volume>70</volume>, <fpage>1</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.3989/mc.2020.09219</pub-id>
</mixed-citation>
</ref>
<ref id="B26">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Tan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Thermal and mechanical properties of thermal energy storage lightweight aggregate mortar incorporated with phase change material</article-title>. <source>J. Energy Storage</source> <volume>32</volume>, <fpage>101719</fpage>. <pub-id pub-id-type="doi">10.1016/j.est.2020.101719</pub-id>
</mixed-citation>
</ref>
<ref id="B27">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Su</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Darkwa</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kokogiannakis</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Review of solid&#x2013;liquid phase change materials and their encapsulation technologies</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>48</volume>, <fpage>373</fpage>&#x2013;<lpage>391</lpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2015.04.044</pub-id>
</mixed-citation>
</ref>
<ref id="B28">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tafesse</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>H.-K.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>The role of carbon nanotube on hydration kinetics and shrinkage of cement composite</article-title>. <source>Compos. Part B Eng.</source> <volume>169</volume>, <fpage>55</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.compositesb.2019.04.004</pub-id>
</mixed-citation>
</ref>
<ref id="B29">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Togun</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Basem</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Jweeg</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Mohammed</surname>
<given-names>H. I.</given-names>
</name>
<name>
<surname>Abed</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Anqi</surname>
<given-names>A. E.</given-names>
</name>
<etal/>
</person-group> (<year>2025</year>). <article-title>A review of phase-change materials for building applications: innovations, assessments, and design Implications</article-title>. <source>Energy Build.</source> <volume>349</volume>, <fpage>116573</fpage>. <pub-id pub-id-type="doi">10.1016/j.enbuild.2025.116573</pub-id>
</mixed-citation>
</ref>
<ref id="B30">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tripathi</surname>
<given-names>B. M.</given-names>
</name>
<name>
<surname>Shukla</surname>
<given-names>S. K.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>A comprehensive review of the thermal performance in energy efficient building envelope incorporated with phase change materials</article-title>. <source>J. Energy Storage</source> <volume>79</volume>, <fpage>110128</fpage>. <pub-id pub-id-type="doi">10.1016/j.est.2023.110128</pub-id>
</mixed-citation>
</ref>
<ref id="B31">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vedrtnam</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Kalauni</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Soares</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Salazar</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Ostertag</surname>
<given-names>C. P.</given-names>
</name>
<name>
<surname>Taylor</surname>
<given-names>H. K.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Phase change materials for climate-adaptive buildings: a review framed by tropical and mediterranean climates</article-title>. <source>J. Energy Storage</source> <volume>125</volume>, <fpage>116938</fpage>. <pub-id pub-id-type="doi">10.1016/j.est.2025.116938</pub-id>
</mixed-citation>
</ref>
<ref id="B32">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Verbeke</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Audenaert</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Thermal inertia in buildings: a review of impacts across climate and building use</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>82</volume>, <fpage>2300</fpage>&#x2013;<lpage>2318</lpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2017.08.083</pub-id>
</mixed-citation>
</ref>
<ref id="B33">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Parametric analysis of applying PCM wallboards for energy saving in high-rise lightweight buildings in Shanghai</article-title>. <source>Renew. Energy</source> <volume>145</volume>, <fpage>52</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.renene.2019.05.124</pub-id>
</mixed-citation>
</ref>
<ref id="B34">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Qu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Enhancing thermal regulation and mechanical properties of phase change mortar using carbon nanomaterials</article-title>. <source>Constr. Build. Mater.</source> <volume>494</volume>, <fpage>143448</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2025.143448</pub-id>
</mixed-citation>
</ref>
<ref id="B35">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xiong</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Shah</surname>
<given-names>K. W.</given-names>
</name>
<name>
<surname>Kua</surname>
<given-names>H. W.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Application of graphite platelets for heat transfer enhancement of cementitious composites containing microencapsulated phase change materials</article-title>. <source>Constr. Build. Mater.</source> <volume>318</volume>, <fpage>126024</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2021.126024</pub-id>
</mixed-citation>
</ref>
<ref id="B36">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Cui</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Bao</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Tang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Sang</surname>
<given-names>G.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Cementitious composites integrated phase change materials for passive buildings: an overview</article-title>. <source>Constr. Build. Mater.</source> <volume>361</volume>, <fpage>129635</fpage>. <pub-id pub-id-type="doi">10.1016/j.conbuildmat.2022.129635</pub-id>
</mixed-citation>
</ref>
</ref-list>
<fn-group>
<fn fn-type="custom" custom-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/278824/overview">Antonio Caggiano</ext-link>, University of Genoa, Italy</p>
</fn>
<fn fn-type="custom" custom-type="reviewed-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2039687/overview">Wei Zhang</ext-link>, Fujian University of Technology, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3557635/overview">Zain Ijaz</ext-link>, Tongji University, China</p>
</fn>
</fn-group>
</back>
</article>