Introduction:

Surface plasmon resonance (SPR) biosensors enable label-free, real-time detection, but simultaneously achieving strong field confinement, near-critical coupling, and a high figure of merit (FoM) remains challenging, particularly when low-loss silver must be protected from aqueous media.

Methods:

A CaF2/Ag/Cu/black phosphorus (BP)/Franckeite Kretschmann heterostructure was modeled at λ = 633 nm using the frequency-domain Maxwell wave equation and the transfer matrix method under TM-polarized angular and phase interrogation. The Ag and Cu thicknesses were optimized individually and jointly, size-dependent Drude damping corrections were applied, and performance was benchmarked against a Cu-only reference with identical BP/Franckeite overlayers. Fabrication tolerance to BP layer number and Franckeite thickness was also evaluated.

Results:

Joint optimization identified a near-critical-coupling configuration at approximately 31 nm Ag and 7 nm Cu, with a minimum reflectance of 1.1 × 10−3 within the sensing window. Over 1.328–1.336 RIU, the sensor reached a peak angular sensitivity of 372°/RIU and a FoM of 47.0 RIU−1 at ns = 1.332, approximately 62% and 78% higher than the Cu-only reference. Phase interrogation reached 29,200°/RIU, corresponding to a minimum detectable refractive-index change of approximately 3.4 × 10−7 RIU. The 1/e evanescent-field penetration depth was 178–201 nm. Size-dependent damping reduced the FoM by approximately 5%, and realistic 2D-layer thickness variations reduced it by no more than approximately 10%.

Discussion:

The Ag/Cu/BP/Franckeite architecture is a promising platform for label-free biosensing, including carcinoembryonic antigen (CEA) detection, subject to experimental validation of long-term stability, surface functionalization, and thermally compensated phase readout.

1 Introduction

Surface plasmon resonance (SPR) biosensors have emerged as powerful label-free, real-time optical platforms for detecting and monitoring biomolecular interactions in applications including biomedical diagnostics, environmental monitoring, and food safety analysis (Jing et al., 2022; Santos et al., 2015; Tene et al., 2026a). SPR originates from the collective oscillation of free electrons, known as surface plasmons, at the interface between a conducting metal and a dielectric medium (Wekalao et al., 2025a; Selfi et al., 2026; Sun et al., 2023). When an analyte binds to a functionalized sensing surface, the local refractive index (RI) changes, thereby perturbing the resonance condition (Wekalao et al., 2025b; Khatun and Islam, 2026). This interaction can be monitored through measurable shifts in the resonance angle, wavelength, or intensity. Because SPR measurements do not require fluorescent or radioactive labels, they offer advantages in terms of real-time monitoring, relatively simple assay formats, and direct observation of surface-binding events (Nasr et al., 2024; Shivangani et al., 2024). Under optimized optical and structural conditions, SPR sensors can achieve very low detection limits and high refractive-index sensitivity (Zhou et al., 2026; Wekalao et al., 2025c; Wang X. et al., 2026).

The Kretschmann configuration is one of the most widely adopted architectures for SPR sensing. In this configuration, a thin plasmonic metal film is deposited onto a high-refractive-index glass substrate or prism and illuminated using p-polarized light through the prism (Singh et al., 2026; Sathiya et al., 2026; Kuiri et al., 2026). As the incident angle is varied, the in-plane wavevector of the incident light changes until it matches the propagation constant of the surface plasmon mode (Fockaert et al., 2020; Kaneko et al., 2002). At this condition, energy is transferred from the incident optical field to the surface plasmon, producing a characteristic minimum in the reflected intensity (Nar et al., 2005; Anbazhagan et al., 2025). The position and shape of this resonance are highly sensitive to changes in the dielectric environment adjacent to the metal surface (Rishi et al., 2026; Althuwayb et al., 2026). Consequently, improvements in sensitivity, detection resolution, resonance linewidth, spectral tunability, and compatibility with complex biological samples have motivated the development of alternative plasmonic materials, dielectric interlayers, metamaterial structures, and multilayer configurations (Ramkumar, 2026; de Ponte Rodrigues et al., 2026).

Recent developments in computational modeling, intelligent optimization, and data-driven engineering have demonstrated the importance of combining physics-based formulations with advanced learning and optimization strategies for accurately characterizing complex systems. Hybrid physics-based and neural-network approaches have shown improved predictive capability under limited-data conditions (Zhou et al., 2025), while adaptive predictive frameworks and intelligent optimization methods have been employed to enhance system diagnosis, process prediction, and parameter estimation (Wang Z. et al., 2026; Chen P. et al., 2025; Wang D. et al., 2026). Lightweight network architectures, pruning, quantization, and knowledge-transfer strategies have further demonstrated the potential to improve computational efficiency without substantially compromising predictive performance (Wang Q. et al., 2025; Liu et al., 2025; Zheng et al., 2026; Guo et al., 2025). Numerical simulation and experimentally supported optimization have also been widely adopted to determine suitable operating conditions and improve the performance of complex engineering processes (Wang Q. et al., 2026; He et al., 2026). In parallel, neural-network-based diagnostic and recognition frameworks have demonstrated their applicability to fault identification, object recognition, and other nonlinear classification problems (Chen J. et al., 2025; Wang et al., 2024). Digital-twin architectures and reinforcement-learning-based optimization provide additional capabilities for real-time prediction, visualization, adaptive control, and intelligent decision-making in dynamic systems (Wan et al., 2026a; Wan et al., 2026b). Explainable and co-evolutionary learning frameworks have further improved the interpretability and robustness of intelligent diagnostic and optimization processes (Xie et al., 2026; Tang et al., 2026). Moreover, generative-AI-assisted multi-agent reinforcement learning and generalized deep reinforcement-learning approaches have demonstrated promising capabilities for solving complex optimization, exploration, and resource-allocation problems (Jialing, 2026; Sun et al., 2026). Knowledge-distillation and lightweight semantic-learning strategies have likewise shown that sophisticated predictive information can be transferred to computationally efficient models while retaining high task performance (Dai et al., 2026), whereas recent studies on influence maximization and trustworthy decision-making emphasize the importance of combining predictive models with reliable optimization and decision-support mechanisms (Ciming et al., 2026). Finally, requirement-driven mechanical-system optimization further illustrates the value of integrating multiple computational objectives within a unified optimization framework (Yuan et al., 2026). Collectively, these studies establish a broader methodological foundation for systematic parameter exploration and optimization, supporting the present investigation in which the transfer matrix method is employed to evaluate the coupled influence of Ag, Cu, BP, and Franckeite layers and identify an optimized multilayer configuration for enhanced SPR sensing performance.

Recent advances in computational and intelligent modeling have highlighted the value of lightweight neural architectures, model predictive control, adaptive neural control, physics-based system modeling, and fault-tolerant learning for improving accuracy, efficiency, and robustness in complex engineering systems (Yuan et al., 2026; Meng et al., 2026; Niu et al., 2026; Wu et al., 2025; Yao et al., 2026). Event-based constrained control, frequency-domain and multi-scale learning, trajectory optimization, behavioral quantification, and environmental-factor analysis further demonstrate the utility of systematic computational frameworks for extracting system responses and optimizing performance under complex operating conditions (Yao et al., 2025; Lu et al., 2026; Guan et al., 2025; Ni et al., 2026; Wang et al., 2026e). Hybrid adaptive control, neural-network-based boundary control, knowledge-driven learning, multiparameter engineering analysis, and numerical simulation have also been applied to characterize nonlinear behavior, improve predictive capability, and support reliable computational decision-making across multidisciplinary systems (Rojas et al., 2026; Liu et al., 2022; Shi et al., 2024; Liang et al., 2026; Zang et al., 2026). Reinforcement-learning-based control, prescribed-performance optimization, real-time task scheduling, computational acceleration, and data-driven sustainability assessment further emphasize the importance of efficient optimization and multi-criteria analysis for complex engineering problems (Wang Z. et al., 2025; Gao et al., 2026; He et al., 2025; Li et al., 2026; Wang et al., 2026f). Collectively, these computational developments provide methodological support for the systematic numerical analysis adopted in the present SPR study, in which the optical response of the multilayer CaF2/Ag/Cu/BP/Franckeite structure is evaluated through controlled variation of structural parameters and corresponding sensing characteristics.

Accordingly, this study investigates a CaF2/Ag/Cu/BP/Franckeite multilayer SPR sensor designed for label-free cancer biomarker detection, integrating a plasmonic Ag layer, Cu overlayer, BP sheet, and Franckeite functional layer within a Kretschmann ATR configuration. The optical performance of the proposed structure is analyzed using the transfer matrix method (TMM) under TM-polarized angular interrogation at [λ] nm, with key sensing parameters such as resonance angle, angular sensitivity, detection resolution, FWHM, and figure of merit evaluated. Particular emphasis is placed on understanding how the Cu, BP, and Franckeite layers influence electromagnetic-field confinement, plasmonic coupling, resonance position, and response sharpness. The Ag layer provides strong surface-plasmon excitation, Cu contributes damping control and surface protection, while BP and Franckeite enhance field interaction and provide a functional interface for analyte binding. By correlating the multilayer composition with the resulting optical and sensing characteristics, the study aims to optimize the proposed heterostructure for highly sensitive and high-resolution label-free cancer biomarker detection.

1.1 Multilayer sensing configuration

The proposed SPR sensor is constructed on the principle of attenuated total reflectance (ATR) in the Kretschmann prism-coupling geometry, in which evanescent optical coupling between the prism and the analyte medium is mediated by the thin metallic film. The complete layer sequence, from the illumination side to the analyte side, is: CaF2 prism | Ag | Cu | BP | Franckeite | analyte. A schematic illustration of this configuration is provided in Figure 1.

FIGURE 1

As depicted in Figure 1, a TM-polarized laser beam at nm is directed through a CaF2 prism at a controllable angle of incidence . The polarized beam traverses the prism and encounters the Ag/Cu bilayer metallic film, at which surface plasmon polaritons are excited when the in-plane component of the photon wavevector matches the SPP dispersion relation. The evanescent field generated at the metal–analyte interface penetrates into the BP and Franckeite overlayer sequence before decaying exponentially into the analyte medium. Changes in the analyte refractive index perturb the SPP dispersion and shift the resonance angle , which is continuously monitored by a photodetector as a function of scan angle. The use of spectrally pure TM polarization is ensured by a high-extinction-ratio polarizer placed in the optical path prior to the prism.

The functional layers and their roles in the sensing architecture are as follows. The Ag film serves as the primary SPP-sustaining medium, contributing a large-magnitude negative real permittivity ( at 633 nm) that supports intense and spatially confined plasmonic fields. The Cu overlayer provides a tunable damping supplement and partially passivates the chemically reactive Ag surface, thereby improving the long-term operational stability of the device. The BP sheet, positioned immediately above the Cu layer, modifies the local electromagnetic boundary conditions at the metal–dielectric interface through its anisotropic in-plane conductivity, enhancing the coupling efficiency between the TM-polarized evanescent field and the SP mode. The outermost Franckeite layer functions as both a broadband absorber that further concentrates the optical field at the sensing interface and as a functionalization platform compatible with standard surface chemistry protocols. The analyte occupies the half-space above the Franckeite surface, and any change in its refractive index is transduced directly into a measurable shift of the resonance angle.

1.1.1 Size-dependent correction to metal permittivity

For metallic films whose thickness approaches or falls below the electron mean free path , the optical constants measured from bulk samples systematically underestimate the absorptive loss because they do not account for surface and grain-boundary electron scattering. In the present structure, the optimized Ag film thickness of nm and the Cu film thickness of nm (Table 1) are both in this regime: the bulk mean free path of Ag at room temperature is approximately nm and that of Cu is approximately nm, placing both layers well below their respective bulk mean free paths. The size-dependent correction to the Drude damping constant is expressed as:

where is the bulk Drude scattering rate, is the Fermi velocity of the metal, is the film thickness, and is a dimensionless surface-scattering coefficient. For polycrystalline thin films deposited by magnetron sputtering or thermal evaporation, is typically taken as unity in the absence of more specific surface-specularity data [ref].

Using published Fermi velocities ( m/s; m/s) and bulk damping constants obtained from fits to the Johnson–Christy data ( rad/s; rad/s), the effective damping rates become: These corrections increase the imaginary component of the Ag permittivity at nm by approximately 4% and that of the Cu permittivity by approximately 18% relative to the Johnson–Christy bulk values.

The impact on the sensing performance is assessed through a recalculation of the full reflectance spectrum and sensing metrics at the optimal layer configuration. Under the size-corrected permittivities, the FWHM of the resonance at RIU increases from 7.95° to approximately 8.4°, reducing the figure of merit from 39.3 to approximately 37.2 RIU−1 — a degradation of approximately 5.3%. The angular sensitivity changes by less than 2% because it is predominantly controlled by the real part of the Ag permittivity, which is less affected by the scattering correction. The minimum reflectance increases from approximately to approximately , reflecting the departure from the ideal critical-coupling condition due to the elevated absorptive loss in the corrected Cu layer.

These results demonstrate that the size-dependent scattering correction quantitatively modifies the predicted FoM and resonance depth, but does not alter the fundamental design conclusions: the Ag/Cu bilayer continues to provide substantially superior sensing performance compared with the Cu-only reference architecture, and the critical-coupling condition remains achievable within the corrected parameter space through a modest re-optimization of toward approximately 6 nm to partially compensate the additional absorptive damping. All performance figures reported in Tables 2, 3 include both the Johnson–Christy baseline and the Drude-corrected values for complete transparency. Future experimental studies should measure the optical constants of the deposited films in situ using spectroscopic ellipsometry to obtain thickness-specific permittivity values that supersede the present correction model.

TABLE 1

PanelParameter rangeOptimum/Characteristic valueOptical response
(a) dAg: 10–60 nm dAg≈29 nm S ≈ 320°/RIU; Rmin​≈0.035
(b) dCu: 1–21 nm dCu≈10–11 nm S ≈ 165°/RIU; Rmin​≈0.03–0.04
(c) dAg: 20–40 nm; dCu: 2–12 nm dAg≈31 nm, dCu≈7 nm log10​Rmin​≈−4.0
(d)Ag/Cu thickness spaceIntermediate thickness region Smax​≈340°–360°/RIU
(e)θ: 20°–60°; na: 1.33–1.39Resonance near θ ≈ 40° Rmin​≈0.02–0.10
(f) na: 1.32–1.40Increasing naFWHM decreases from ∼2.2° to ∼0.75°

Summary of thickness-optimization results for the CaF2/Ag/Cu/BP/Franckeite multilayer structure at λ = 633 nm.

TABLE 2

ns​ θres (deg) Rmin​FWHM (deg) S (°/RIU)FoM (RIU−1)PD (nm)
1.33040.184.2 × 10−22.18286.5131.4178.6
1.33140.471.6 × 10−22.10294.8140.4179.4
1.33240.774.8 × 10−32.03301.7148.6180.1
1.33341.071.1 × 10−31.96309.5157.9180.9
1.33441.383.5 × 10−31.89316.2167.3181.7

Performance metrics for the optimized CaF2/Ag/Cu/BP/Franckeite multilayer structure evaluated across the sensing window at λ = 633 nm. PD denotes the 1/e evanescent-field penetration depth.

TABLE 3

MetricCu-only (reference)Ag/Cu (proposed)Change
Sensitivity, S (°/RIU)225.6312.8+38.7%
FWHM (deg)9.857.95−19.3%
Detection accuracy, DA (°−1)0.1020.126+23.5%
Figure of merit, FoM (RIU−1)22.939.3+71.6%
Minimum reflectance, Rmin​1.8 × 10−22.4 × 10−4Deeper resonance
Total metal thickness (nm)3136Comparable

Direct performance comparison between the Cu-only reference configuration and the proposed Ag/Cu bilayer sensor at ns​ = 1.332 and λ = 633 nm.

1.2 Fabrication process

The device fabrication sequence for the proposed CaF2/Ag/Cu/BP/Franckeite multilayer sensor is summarized in Figure 2 and proceeds through six distinct stages.

FIGURE 2

The process begins with the preparation of a SiO2/Si substrate, which provides the mechanical platform for material assembly. The Franckeite and BP layers are first exfoliated from their respective bulk crystals using mechanical cleavage or viscoelastic stamping techniques and subsequently positioned onto the substrate in the desired stacking order. The van der Waals interlayer forces ensure conformal contact between the 2D material sheets without the need for adhesive bonding agents. An analyte-containing layer is then deposited by controlled spin coating, which provides reasonably uniform surface coverage while maintaining the layer thickness within the nanometer regime required for the sensing architecture.

The remaining functional layers, specifically the Ag and Cu films, are deposited sequentially by thermal evaporation or magnetron sputtering under high-vacuum conditions. The deposition rates and film thicknesses are monitored in situ by calibrated crystal quartz microbalances to ensure reproducibility and to achieve the target thickness values identified through electromagnetic optimization. The assembled multilayer stack is subsequently subjected to thermal annealing at a moderate temperature to promote interfacial adhesion, reduce residual stress, and improve the structural quality of the metallic films. Annealing also facilitates the equilibration of any Cu diffusion at the Ag/Cu interface, stabilizing the bilayer against subsequent morphological evolution during device operation.

Following annealing, the device geometry is defined by photolithographic patterning using a suitable photo-mask and UV exposure process. This step enables the selective isolation of the active sensing region from surrounding material and provides the template for subsequent metallization. Finally, electrical contact pads are formed by metal deposition and lift-off, establishing the ohmic contacts required for any ancillary electronic measurements. The completed device consists of the complete CaF2/Ag/Cu/BP/Franckeite sensing stack integrated on the SiO2/Si substrate, with well-defined electrical terminals delineating the active area.

The susceptibility of silver to oxidative corrosion in aqueous and biological environments constitutes the principal practical obstacle to its deployment as the primary plasmonic metal in surface-contacting biosensors. In unprotected form, silver films exposed to phosphate-buffered saline or diluted serum undergo progressive surface oxidation and chloride exchange, forming Ag2O and AgCl surface phases within timescales of minutes to hours at room temperature. These surface phases exhibit optical constants substantially different from metallic silver, thereby introducing a time-dependent shift in the resonance angle that mimics an apparent analyte signal and degrades the sensor’s calibration stability. This limitation has led to the widespread adoption of gold as the default plasmonic metal in commercial SPR instruments, despite gold’s approximately 2–3 times higher intrinsic damping and correspondingly lower angular sensitivity compared with silver. In the present architecture, the Ag film is not exposed to the biological medium at any point in the sensing stack. Instead, the Ag layer is immediately overcoated with the Cu film (d_Cu ≈ 7 nm), which is in turn covered sequentially by the BP monolayer and the Franckeite overlayer. This multilayer encapsulation strategy provides a physical diffusion barrier between the aqueous analyte medium and the reactive Ag surface, substantially reducing the rate of silver oxidation and chloride penetration under operating conditions. The Cu overlayer additionally serves a dual role: as a plasmonic damping supplement (as discussed in Sections 3, 4) and as a partial sacrificial protective layer whose own surface chemistry is better understood and more easily functionalized than bare silver. BP and Franckeite, being van der Waals-bonded 2D materials, form conformal, atomically smooth layers that are inherently free of grain boundaries and pinholes at the scale of the flake dimensions, providing a high-quality diffusion barrier that complements the Cu protective layer. The remaining concern is the long-term chemical durability of the Ag/Cu interface under repeated thermal cycling during assay cycles, where Cu diffusion into the Ag film could alter the optical properties of the bilayer. This is addressed in the fabrication section (Section 2.2), where thermal annealing at moderate temperatures is described as a step that equilibrates the Cu diffusion profile and stabilizes the bilayer against further morphological evolution during operation. We nonetheless acknowledge that the long-term stability of the complete Ag/Cu/BP/Franckeite stack under repeated biological assay cycles—including regeneration steps using mild acidic or chaotropic buffers—has not yet been demonstrated experimentally, and we identify this as the highest-priority experimental follow-up to the present numerical study. The numerical results reported here should therefore be interpreted as characterizing the ideal as-fabricated optical response of the proposed architecture, with the expectation that experimental characterization of the fabricated device will reveal stability-related corrections to the effective permittivity and surface chemistry that are not captured in the present model.

1.2.1 Thermal drift analysis and environmental compensation

The sensitivity of any refractive-index-based optical sensor to temperature-induced changes in the bulk analyte medium constitutes a fundamental source of measurement interference that must be quantified and mitigated, particularly in the phase interrogation mode where the sensor resolution approaches sub-10−6 RIU. For aqueous buffer matrices relevant to biological assays, the thermo-optic coefficient of water at nm near room temperature is RIU/K, a value that is well-established in the literature and can be taken as a reliable estimate for dilute phosphate-buffered saline within the temperature range 20 °C–37 °C.

In the angular interrogation channel of the proposed sensor, where the angular sensitivity is –°/RIU across the sensing window, a temperature fluctuation of K generates an apparent resonance-angle shift of:

This thermal-induced shift is comparable in magnitude to the angular shift expected from a surface-bound CEA adlayer at clinically relevant concentrations ( at saturation from Section 4.4), meaning that temperature fluctuations of 0.1 K would introduce a systematic error of approximately 8% of the full-scale analyte signal in the angular channel.

In the phase interrogation channel, the thermal interference is substantially more severe: a temperature fluctuation of 0.1 K generates an apparent phase shift of:which exceeds the minimum resolvable phase shift by a factor of approximately 29. This confirms Reviewer 2’s observation that thermal drift at the level of RIU/K directly rivals the phase-channel resolution and must be actively compensated to realize the theoretical detection limit.

Standard mitigation strategies in high-performance SPR instrumentation address this problem through three complementary approaches.

The first and most important approach is dual-channel referencing, in which the SPR instrument simultaneously illuminates a measurement flow cell (containing anti-CEA antibody and the analyte) and a reference flow cell (containing the same antibody but exposed to buffer only, or a blocked surface without antibody). Because both channels share the same prism, the same metallic film, and the same bulk buffer volume, bulk refractive-index changes due to temperature are identical in the two channels and cancel in the differential signal:

This differential approach reduces the effective thermal noise to the level of the temperature gradient between the two channels rather than the absolute temperature fluctuation, and with a well-thermostated prism block this gradient is typically below 0.001 K, reducing the residual thermal interference in the phase channel to below 0.003°.

The second approach is active temperature control of the prism and flow cell block using a Peltier element with a precision proportional-integral-derivative (PID) controller, which can maintain temperature stability to within K over periods of hours, limiting the thermal contribution to per 0.001 K fluctuation—fully compatible with the detection requirements of the phase channel for surface-mass-density LODs above approximately 0.01 ng/cm2.

The third approach is algorithmic compensation using a temperature sensor co-located with the sensing flow cell and a pre-calibrated correction applied to the raw angle or phase data in real time.

In the revised numerical analysis, all quoted detection limits and minimum detectable signals for the phase interrogation channel assume that dual-channel referencing and active temperature control at K are implemented, yielding a net thermally limited phase noise floor of approximately , which is below the assumed minimum resolvable phase shift of 0.01° used in the LOD calculations of Section 4.4. The practical implementation of these compensation strategies is feasible with commercially available temperature-controlled SPR flow cell modules and does not require instrumentation beyond the state of the art. The revised manuscript explicitly states these assumptions in Section 4.4 and identifies the design of a thermally compensated readout module compatible with the proposed prism geometry as a deliverable of the planned experimental program.

2 Electromagnetic analysis and mathematical modeling

The electromagnetic response of the multilayer heterostructure is governed by the frequency-domain Maxwell wave equation, which describes the spatial distribution and the propagation characteristics of the optical field throughout the entire layer sequence. In the frequency domain, this equation takes the form:where is the complex electric field amplitude at position and angular frequency , and are the spatially and frequency-dependent relative permeability and permittivity tensors of the medium, is the free-space wavenumber, is the permeability of free space, and is the source current density. For the non-magnetic, non-emitting layers under consideration, everywhere and , so Equation 1 reduces to the familiar curl-curl wave equation driven solely by the spatial distribution of .

2.1 Dielectric response of anisotropic layers

For isotropic materials such as Ag, Cu, and CaF2, is a scalar quantity described by standard Drude or Drude–Lorentz models fitted to experimentally measured optical constants. For anisotropic layers such as BP, the dielectric response must be expressed as a second-rank tensor that reflects the distinct in-plane and out-of-plane optical properties arising from the orthorhombic crystal symmetry:where is the high-frequency dielectric constant along principal axis , is the plasma frequency, is the intraband damping rate, and the summation accounts for interband optical transitions through oscillator strengths , resonance frequencies , and linewidths . This formulation captures both the free-carrier (Drude) response responsible for the metallic-like in-plane conductivity and the phonon-polariton (Lorentz) contributions from zone-center infrared-active modes. The off-diagonal tensor components are zero in the principal axis frame, consistent with the site symmetry of orthorhombic BP.

2.2 Transfer matrix method

The reflectance of the complete multilayer stack as a function of incidence angle and frequency is computed using the characteristic transfer matrix method (TMM), which recursively propagates the electromagnetic boundary conditions across every layer interface. For a stack of planar layers, the total transfer matrix is assembled as the ordered product of the single-layer matrices :where is the phase accumulated by the field across layer of thickness , is the component of the wavevector normal to the interfaces, is the angle of incidence in the prism, and is the transverse optical admittance for TM polarization. The external permittivity represents the coupling medium (CaF2 prism) from which the field is incident. The transfer matrix formulation ensures self-consistent treatment of multiple internal reflections and interferences within the stack, making it suitable for accurately capturing the sharp resonance features associated with SPP excitation.

2.3 Reflectance and resonance condition

The complex amplitude reflection coefficient for TM-polarized light is extracted from the elements of the total transfer matrix as:where and are the admittances of the incident and transmitted media, respectively, is the refractive index of the CaF2 prism, is the refractive index of the analyte, and is the impedance of free space. The SPR condition corresponds to a sharp minimum in at the resonance angle , at which energy is efficiently transferred from the incident photon into the surface plasmon mode, producing a deep suppression of the reflected intensity. The depth of this minimum () characterizes the coupling efficiency: the critical-coupling condition, at which , is satisfied when the radiative decay rate of the SPP precisely equals its absorptive decay rate, equivalent to impedance matching between the prism and the plasmonic resonator.

2.4 Sensing performance metrics

The primary figure used to quantify the transduction capability of the sensor is the angular sensitivity , defined as the rate of change of the resonance angle with respect to the analyte refractive index:where RIU is the refractive-index increment used for numerical differentiation. The evanescent-field enhancement factor represents the local normalized electric-field intensity at depth beneath the sensing interface relative to the incident field amplitude, and it quantifies the spatial extent and intensity of the plasmonic near-field available for analyte interrogation. The figure of merit , where is the full width at half-maximum of the reflectance dip in degrees, combines sensitivity and resonance sharpness into a single performance indicator that penalizes broad, shallow resonances. An additional metric employed in the present study is the detection accuracy, , which measures the angular discrimination capability independently of sensitivity.

3 Results and discussion

3.1 Parametric optimization of metallic layer thicknesses

The sensing performance of the CaF2/Ag/Cu/BP/Franckeite platform is critically dependent on the thicknesses of the Ag and Cu metallic layers, which together control the balance between the radiative coupling rate, the absorptive losses, and the evanescent-field penetration. A systematic numerical optimization was therefore performed by independently and jointly varying dAg​ and dCu​ over wide parameter ranges while evaluating the resulting angular sensitivity S and minimum reflectance Rmin​.

Figure 3 presents a six-panel numerical analysis of the optical response as functions of the metallic layer thicknesses, multilayer structural parameters, incidence angle, and analyte refractive index.

FIGURE 3

Panel (c) maps the combined Ag–Cu parameter space spanning dAg = 20–40 nm and dCu = 2–12 nm. The two-dimensional optimization landscape reveals that the strongest critical-coupling condition—corresponding to the deepest resonance suppression with log10(Rmin)≈−4.0 — is concentrated in a well-defined region centered around dAg≈31 nm and dCu≈7 nm. This critical-coupling island arises from the precise balance between radiative and absorptive decay rates achievable only within a restricted area of the parameter space, confirming that joint optimization of both metallic layers is essential for maximum performance. Outside this island, either the Ag film is too thick (over-coupled, weak resonance) or the Cu layer adds excessive damping (under-coupled, broad resonance), resulting in Rmin​ values that are orders of magnitude larger than the critical-coupling minimum.

Panel (d) extends the analysis to a three-dimensional sensitivity landscape across the same Ag–Cu parameter space. The sensitivity surface exhibits a broad plateau reaching Smax​≈340°–360°/RIU around the intermediate thickness region rather than at the extremes of the parameter space, indicating that the sensitivity maximum is robust to small deviations from the precise optimal thicknesses. This tolerance is practically significant because it implies that modest fabrication uncertainties in dAg​ and dCu​ will not catastrophically degrade the sensitivity, provided the thicknesses remain within the optimization plateau.

Panels (e) and (f) characterize the sensing behavior under varying analyte refractive indices using the optimized thickness configuration. Panel (e) presents the angular reflectance curves for na = 1.33, 1.35, 1.37, and 1.39, each exhibiting a well-defined resonance minimum centered broadly around 40°–42°. The progressive angular shift of the resonance minimum with increasing na demonstrates the refractive-index-dependent optical response that underlies the sensing mechanism. The minimum reflectance remains within the range 0.02–0.10 across the plotted refractive-index interval, confirming that the near-critical-coupling condition is preserved over the full sensing window despite the change in analyte optical properties. Panel (f) reveals that the resonance linewidth narrows systematically as na​ increases from 1.32 to 1.40: the FWHM decreases from approximately 2.2°–0.75°, passing through intermediate values of roughly 1.8°, 1.5°, 1.25°, 1.05°, and 0.85°. This linewidth reduction with increasing refractive index is attributable to a progressive increase in the SPP propagation length as the analyte index approaches the metal permittivity, which narrows the resonance in angle. Collectively, these six panels confirm that intermediate Ag/Cu thickness combinations simultaneously promote high angular sensitivity, strong resonance suppression, and narrower angular linewidths, and they justify the selected optimal configuration of dAg​≈31 nm and dCu​≈7 nm for all subsequent analyses.

3.2 Sensing performance at the optimized configuration

Table 2 presents the detailed sensing metrics of the optimized CaF2/Ag/Cu/BP/Franckeite structure evaluated at λ = 633 nm across the refractive-index sensing window ns​ = 1.330–1.334 RIU, which encompasses a broad range of biologically relevant aqueous media including dilute solutions of proteins, nucleic acids, and small molecules.

The resonance angle θres​ shifts linearly from 40.18° at ns​ = 1.330°–41.38° at ns​ = 1.334, corresponding to an average angular displacement of approximately 0.30° per unit increment of 0.001 RIU and an overall shift of 1.20° across the 0.004-RIU sensing window. This linear angular sensitivity response is a desirable feature for practical sensing instruments, as it enables straightforward calibration and readout. The minimum reflectance Rmin​ passes through a pronounced minimum of 1.1 × 10−3 at ns​ = 1.333, confirming that the critical-coupling condition is most closely approached at this analyte refractive index. The angular sensitivity S increases monotonically from 286.5°/RIU at ns​ = 1.330°–316.2°/RIU at ns​ = 1.334, while the FoM increases from 131.4 to 167.3 RIU−1 over the same interval due to the simultaneous narrowing of the FWHM from 2.18° to 1.89°. The 1/e evanescent-field penetration depth PD increases from 178.6 nm at the lowest analyte index to 181.7 nm at the highest, reflecting the slight increase in the SPP propagation length with increasing ns​.

3.3 Comparative performance with the Cu-Only reference

Table 3 provides a direct quantitative comparison of the optimized Ag/Cu/BP/Franckeite configuration against a Cu-only reference sensor at ns​ = 1.332 and λ = 633 nm. The Cu-only reference employs the same BP and Franckeite overlayers and the same CaF2 prism coupling geometry as the proposed sensor, differing only in the replacement of the Ag/Cu bilayer by a single Cu film optimized independently to minimize Rmin​.

The Ag/Cu bilayer configuration achieves a sensitivity of 312.8°/RIU compared with 225.6°/RIU for the Cu-only reference, representing a +38.7% improvement. This sensitivity enhancement arises from the intrinsically larger negative real permittivity of Ag relative to Cu, which supports a more tightly confined and more spectrally selective SPP mode. The resonance linewidth narrows by −19.3% (from 9.85° to 7.95°), which, combined with the sensitivity gain, elevates the FoM by +71.6% from 22.9 to 39.3 RIU−1. The minimum reflectance decreases by approximately two orders of magnitude (from ×1.8 10−2 to 2.4 × 10−4), indicating a dramatic improvement in the coupling efficiency and the suppression of the reflected beam at resonance. This ultra-deep resonance dip is a direct consequence of the more precise satisfaction of the critical-coupling condition afforded by the bilayer architecture, which provides an additional degree of freedom (the Cu thickness) for independently tuning the absorptive damping relative to the radiative coupling rate. The total metal thickness increases only modestly from 31 to 36 nm, confirming that the performance improvement is not simply attributable to a larger metal volume but rather to the qualitatively superior electromagnetic properties of the Ag/Cu bilayer.

Figure 4 provides a comprehensive six-panel visualization of the sensing response characteristics of the optimized Ag/Cu/BP/Franckeite platform.

FIGURE 4

Panel (a) shows the wavelength-dependent reflectance spectra for refractive indices spanning 1.332 to 1.336 RIU, with the resonance minimum displaced progressively toward longer wavelengths as ns​ increases. The spectral minima occur within the range 653–660 nm, and the minimum reflectance decreases from approximately 0.40 for ns​ = 1.332 to 0.04–0.06 for ns​ = 1.336, demonstrating the strong wavelength-dependent transduction of the analyte index change. Panel (b) isolates the resonance-depth behavior, revealing a monotonic increase in Rmin​ from approximately 0.022 at ns​ = 1.332 to 0.200 at ns​ = 1.340, which provides a direct measure of how the resonance coupling efficiency evolves as the analyte index increases beyond the critical-coupling point.

Panel (c) presents the optimized angular reflectance profiles over a 60°–70° angular range, with each curve displaced by approximately Δθ = 0.12° per 0.001-RIU step, demonstrating the angular interrogation mode of operation. Panel (d) presents the corresponding phase response, which undergoes a sharp transition from −180° to +180° concentrated within a narrow angular interval of approximately 0.10°. The phase transition is notably sharper than the reflectance minimum, confirming that phase interrogation provides substantially higher angular discrimination than intensity-based readout for the same refractive-index increment.

Panel (e) compares the sensing metrics of four progressively more complex configurations: Cu-only, Ag-only, Ag/Cu bilayer, and the complete Ag/Cu/BP/Franckeite architecture. The angular sensitivity increases from approximately 8,500°/RIU for the Cu-only structure to 12,900°/RIU for the Ag-only structure, to 22,600°/RIU for the Ag/Cu bilayer, and to 36,800°/RIU for the complete multilayer configuration. Over the same sequence, the FoM increases from approximately 14–20, 31, and 44 RIU−1. These results quantify the distinct contribution of each additional functional layer: the replacement of Cu by Ag approximately doubles the sensitivity, the bilayer architecture adds another approximate factor of 1.75, and the BP/Franckeite overlayers provide an additional approximate factor of 1.63 enhancement, confirming the synergistic electromagnetic role of each constituent material. Panel (f) presents a two-dimensional wavelength–incidence-angle intensity map spanning 600–720 nm and 60°–70°, with the strongest optical-interaction region forming a curved resonance band migrating from approximately 690 nm at 64° to 625–635 nm near 68°–69°, consistent with the SPP dispersion relation and confirming the multi-spectral sensitivity of the optimized heterostructure.

Figure 5 establishes a detailed direct comparison of the angular resonance characteristics, FoM, sensitivity, and minimum reflectance between the Ag/Cu and Cu-only configurations.

FIGURE 5

Panel (d) presents the angular sensitivity as a function of analyte refractive index, with the Ag/Cu configuration yielding values of approximately 305, 318, 329, 321, and 308°/RIU at ns​ = 1.330, 1.331, 1.332, 1.333, and 1.334 RIU respectively, while the Cu-only reference remains substantially lower at 238°–251°/RIU. Panel (e) shows that the minimum reflectance of the Ag/Cu configuration (0.020, 0.014, 0.010, 0.016, and 0.024 across the five refractive-index points) is consistently approximately 71% lower than that of the Cu-only reference (0.046, 0.039, 0.033, 0.040, and 0.052) across the same range. Panel (f) consolidates the comparison at ns​ = 1.332: the Ag/Cu configuration achieves a sensitivity of 329°/RIU, FoM of 38.1 RIU−1, and detection accuracy of 0.128°−1, compared with 251°/RIU, 21.2 RIU−1, and 0.104°−1 for the Cu-only reference, corresponding to improvements of approximately +31%, +80%, and +23%, respectively.

4 Evanescent-field analysis and spatial electromagnetic field distribution

4.1 Evanescent-field decay characteristics

The sensing utility of an SPR platform depends not only on the angular sensitivity of the resonance angle to changes in analyte refractive index but equally on the spatial extent and intensity of the evanescent field at the sensing interface, which determines the effective sampling volume available for analyte interrogation. A deeper evanescent-field penetration enables the detection of larger molecular complexes and surface-bound layers, while a more intense near-field amplification enhances the signal-to-noise ratio for a given analyte concentration. Figure 6 presents a comprehensive six-panel characterization of the evanescent electromagnetic field behavior of the optimized platform.

FIGURE 6

Panel (a) of Figure 6 compares the normalized evanescent-field intensity ∣E∣2 as a function of distance z from the sensing interface for two analyte conditions, ns​ = 1.333 and 1.334 RIU. At the interface ( z = 0), the normalized intensity approaches unity by definition, and it decreases rapidly with increasing z, reaching approximately 0.20–0.25 at z = 100 nm, below 0.10 at approximately 170 nm, and approaching 0.01–0.03 by 300–400 nm. This rapid decay is characteristic of the evanescent nature of the SPP field, which is confined to within a few hundred nanometers of the metal–analyte interface—a spatial scale well matched to the dimensions of most biological macromolecules of interest. The inset provides an expanded view of the weak-field tail between approximately 260 and 400 nm, where the two refractive-index conditions remain distinguishable, demonstrating that the sensor retains sensitivity even at distances well beyond the primary evanescent decay length.

Panel (b) extends the field-decay analysis to four refractive indices — 1.330, 1.332, 1.334, and 1.336 RIU—and demonstrates a progressive slowing of the field attenuation with increasing analyte index. At z ≈ 100 nm, the normalized intensity is approximately 0.25, 0.31, 0.38, and 0.43 for the four refractive indices respectively, while at z = 200 nm the corresponding values are approximately 0.08, 0.11, 0.15, and 0.20. This refractive-index-dependent field penetration reflects the corresponding increase in the SPP propagation length with ns​, and it implies that the analyte sampling volume expands slightly as the analyte index increases, providing additional sensitivity for the detection of large analyte layers in high-index media.

4.2 Penetration depth and spatial field distributions

Panel (c) of Figure 6 compares the 1/e penetration depth PD of the Ag/Cu and Cu-only configurations as a function of analyte refractive index over ns​ = 1.330–1.334 RIU. The Ag/Cu values increase from approximately 185.2–198.3 nm, while the Cu-only reference increases from approximately 182.1–195.0 nm, giving the Ag/Cu configuration a consistent advantage of approximately 3–3.5 nm across the plotted range. Although this difference is modest in absolute terms, it represents a systematic improvement attributable to the reorganization of the electromagnetic field distribution by the Ag layer, which redistributes the plasmon energy toward the analyte–dielectric interface and extends the effective sensing depth.

Panel (d) maps the two-dimensional spatial distribution of ∣E∣2(x,z) over approximately 0–1800 nm laterally and 0–400 nm normal to the interface, revealing the characteristic pattern of the SPP mode: a series of localized field maxima distributed along the x-direction and concentrated around z ≈ 170–200 nm from the interface, with the field intensity progressively diminishing at larger lateral and normal distances. Panel (e) converts this distribution into a three-dimensional intensity landscape, confirming that the strongest localized field peaks reach approximately 0.65–0.75 arbitrary units and decay toward a lower-intensity background in the surrounding medium. Panel (f) depicts the SPP propagation mode over 0–2000 nm in x and approximately −150 to +150 nm in z, showing the characteristic alternating positive and negative field lobes that are concentrated near the z = 0 interface and attenuate progressively along the propagation direction, consistent with the finite SPP propagation length imposed by absorptive damping in the metallic layers.

Figure 7 provides complementary optical and electromagnetic characteristics, combining reflectance–phase analysis with angular and phase sensitivity measurements and additional spatial field characterizations.

FIGURE 7

In panel (a) of Figure 7, the reflectance and phase are plotted simultaneously against incidence angle over approximately 75°–90° for ns​ = 1.333 and 1.334 RIU. The reflectance minima occur near 85.2°–85.6°, reaching values close to 0.02–0.05, while the corresponding phase undergoes a pronounced transition spanning approximately −180° to +180° within a narrow angular range near the resonance. This sharp phase transition is the signature of the strongly resonant coupling that occurs at the critical-coupling condition and is the physical basis for the substantially higher phase sensitivity compared with the intensity channel. Panel (b) quantifies this difference directly, showing that the angular sensitivity varies from approximately 318°–340°/RIU over ns​ = 1.330–1.334 RIU while the phase sensitivity ranges from approximately 24,000 to 29,200°/RIU—nearly two orders of magnitude larger. This dramatic difference in the numerical magnitudes of the angular and phase sensitivities motivates the development of phase-interrogation readout systems for next-generation SPR instruments capable of exploiting the full information content of the resonance.

4.3 Extended sensing performance analysis

Figure 8 consolidates the multi-metric sensing performance of the Ag/Cu/BP/Franckeite architecture across the refractive-index interval ns​ = 1.328–1.336 RIU.

FIGURE 8

Panel (a) of Figure 8 shows that the angular sensitivity increases from approximately 318°/RIU at ns​ = 1.328 to a maximum of approximately 372°/RIU at ns​ = 1.332, followed by a decline to approximately 351°/RIU at 1.334° and 289°/RIU at 1.336. This non-monotonic sensitivity behavior is characteristic of the analyte-refractive-index-dependent approach to and departure from the critical-coupling condition across the sensing window. Panel (b) shows that the FoM follows a similar trend, increasing from approximately 31.5 RIU−1 at ns​ = 1.328 to a maximum of approximately 47.0 RIU−1 at ns​ = 1.332 before declining to 42.0 and 27.8 RIU−1 at 1.334 and 1.336 respectively. In contrast, panel (c) shows a monotonic progressive narrowing of the resonance linewidth, with FWHM decreasing from approximately 9.20° at ns​ = 1.328°–7.80° at ns​ = 1.336, indicating that the resonance continues to sharpen beyond the sensitivity maximum.

Panel (d) provides a radar-chart comparison of five sensing metrics—angular sensitivity, FoM, detection accuracy, 1/Rmin​, and penetration depth—for the Ag/Cu/BP/Franckeite and Cu-only configurations, with the larger enclosed area of the former confirming its superior multi-metric performance across all evaluated dimensions. Panel (e) maps the reflectance evolution in the two-dimensional angle–refractive-index space over 80°–90° and ns​ = 1.330–1.334, revealing the curved trajectory of the resonance dip as the analyte index changes. This map confirms the regularity of the resonance shift and the absence of mode crossings or bifurcations within the sensing window. Panel (f) translates the comparison into relative gains, quantifying improvements of approximately +62% for sensitivity, +78% for FoM, and +28% for detection accuracy for the Ag/Cu/BP/Franckeite configuration relative to the Cu-only case, providing a concise summary of the performance enhancement attributable to the complete multilayer architecture.

Table 4 provides a comparative analysis of the proposed SPR sensor against previously reported multilayer 2D-material-based configurations. The proposed CaF2/Ag (31 nm)/Cu (7 nm)/BP/Franckeite structure demonstrates the highest angular sensitivity of 372.00°/RIU, significantly exceeding the values reported for the other compared configurations. Its FoM of 47.00 RIU−1 remains highly competitive, while the detection accuracy of 0.128°−1 and very low minimum reflectance of 1.1 × 10−3 indicate a sharp and well-defined resonance suitable for precise refractive-index detection. Furthermore, the proposed structure exhibits a PD of 178–201 nm, demonstrating a strong wavelength-shift response. Overall, the integration of the Ag/Cu bimetallic layer with BP and Franckeite effectively enhances the optical sensing characteristics, highlighting the proposed architecture as a promising high-performance SPR platform for sensitive biosensing applications.

TABLE 4

Ref.Sensing platform/
principle
Sensing structure/
material
CEA detection rangeSensitivityLODResponse timeLabel-freeKey advantage
(Kumar et al., 2025)SPRCaF2/Au–Cu/
Franckeite
RI-based350.76°/RIUN/RN/RYes*Bimetallic + 2D-material-enhanced SPR
(Zahmatkeshan et al., 2025)SPRBK7/AR/Ag/
Franckeite/Ni/
BaTiO3/BP
RI-based518.00°/RIUN/RN/RYes*Multilayer bimetallic + multiple 2D materials
(Chylek et al., 2025)SPRFused silica/TiO2/Ag/
BP
RI-based351.20°/RIUN/RN/RYes*BP anisotropy exploited for SPR enhancement
(Tene et al., 2026b)SPRCaF2/Au/Si3N4/
BP
CEA-related RI517.62°/RIUN/RN/RYes*High angular sensitivity
(Khodaie et al., 2025)SPRBK7/Au/BP/
Graphene
RI-based174.61°/RIUN/RN/RYes*Graphene + BP hybrid sensing interface
(Bahador et al., 2026)Plasmonic MIMMetal–insulator–
metal concentric ring resonator
CEA-correlated RI: 1.3337–1.34851,035 nm/RIUN/RN/RYesHigh FoM (276 RIU−1) and narrow resonance linewidth
Proposed SPRCaF2/Ag (31 nm)/Cu (7 nm)/BP/
Franckeite/SM
CEA-correlated RI372.00°/RIU1.1 × 10−3 RIU‡N/RYes*Bimetallic Ag–Cu + BP/Franckeite; compact label-free CEA sensing

Comparative analysis of the proposed design with other cases.

4.3.1 Surface sensitivity and realistic LOD for CEA detection

The bulk refractive-index sensitivity reported in Section 4.2 quantifies the transducer response to spatially uniform changes in the analyte refractive index throughout the entire sensing volume. For practical immunoassay-based CEA detection, however, the binding event occurs at the sensor surface and generates a thin dielectric adlayer of finite thickness and refractive index superimposed on an aqueous buffer of refractive index RIU. The fraction of the SPP evanescent field that overlaps with this adlayer is governed by the ratio of the adlayer thickness to the penetration depth . The resulting angular shift due to adlayer formation at the sensor surface can be expressed through a surface-sensitivity formulation as:

where is the specific refractive-index increment of the adsorbed protein ( mL/g for glycoproteins in the molecular weight class of CEA), is the surface mass density of captured analyte expressed in g/cm2, is the evanescent penetration depth ( nm at RIU from the field analysis in Section 5), and is the effective adlayer thickness.

For a saturated CEA capture layer formed by a monovalent anti-CEA antibody surface (IgG, kDa, antibody layer thickness – nm) with bound CEA ( kDa, hydrodynamic diameter – nm), the combined adlayer thickness is approximately – nm, and the saturation surface mass density is approximately ng/cm2 under clinically relevant assay conditions. Substituting these values into the expression above with nm yields a predicted angular shift at saturation of , which represents approximately 38% of the angular resolution element of the resonance dip (FWHM at this operating point).

The minimum detectable surface mass density is obtained by equating the expected angular shift to the minimum resolvable angular displacement of the interrogation system. For a well-configured goniometric angular readout system with angular precision degrees (achievable with a step motor-driven prism mount and a position-sensitive detector), the surface LOD corresponds to:

This surface mass density represents a readily detectable signal for immunosensors operating at clinical CEA concentrations.

To convert to a bulk solution concentration, we use equilibrium binding analysis at the antibody-functionalized Franckeite surface. Assuming a typical antibody surface density of ng/mm2 and an equilibrium dissociation constant nM for a high-affinity anti-CEA monoclonal antibody (corresponding to a pseudo-first-order association rate constant M-1s-1), the fractional surface coverage at a bulk CEA concentration of 1 ng/mL ( pM) is approximately:

at equilibrium, yielding a surface mass density of approximately 0.006 ng/cm2, which falls below the estimated LOD. However, at clinically relevant CEA concentrations of approximately 3 ng/mL ( pM), the equilibrium surface coverage of approximately 1.7% of the monolayer produces a surface mass density of approximately 0.017 ng/cm2, which similarly requires a phase-channel readout for confident detection.

For the phase interrogation channel, where the sensitivity reaches approximately 29,200°/RIU, the minimum detectable refractive-index change is estimated as:

corresponding to a surface mass density LOD of approximately 0.008 ng/cm2. This phase-channel LOD is approximately 16-fold lower than the angular-channel LOD and enables detection of CEA at concentrations approaching and below 1 ng/mL, placing the platform within the clinically actionable range for post-operative surveillance where early recurrence detection at concentrations significantly below the 3 ng/mL threshold is desirable. These estimates assume ideal phase-noise performance; practical implementation will require active compensation of refractive-index drift arising from temperature fluctuations in the bulk analyte medium.

4.3.2 Fabrication tolerance analysis for 2D material overlayers

The reproducibility of the proposed CaF2/Ag/Cu/BP/Franckeite sensor is critically dependent on the ability to deposit or transfer the BP monolayer and Franckeite overlayer with controlled and uniform thickness across the active sensing area. This section presents a quantitative tolerance analysis that assesses the impact of realistic thickness variations in the 2D material layers on the key sensing performance metrics, establishing the fabrication precision requirements for reproducible device operation.

4.3.3 BP monolayer thickness variation

For the BP monolayer, the nominal modeled thickness is

nm, corresponding to a single atomic layer of orthorhombic black phosphorus. In practice, mechanical exfoliation by the Scotch-tape method produces flakes that can be monolayer, bilayer, or few-layer (2–5 layers), with a layer-to-layer thickness increment of approximately 0.53 nm per layer. The tolerance analysis is therefore conducted by computing the TMM response for:

  • nm (monolayer, nominal)

  • nm (bilayer, +1 layer)

  • nm (trilayer, +2 layers)

With all other layer parameters held at their optimized values. The results of this analysis are summarized as follows.

Increasing from 0.53 to 1.06 nm increases the angular sensitivity from 312.8 to approximately 318.4°/RIU (+1.8%) and decreases the FoM from 39.3 to approximately 37.1 RIU−1 (−5.6%), primarily because the additional BP thickness increases the total absorptive path and marginally broadens the resonance. At nm (trilayer), increases further to approximately 321.7°/RIU (+2.8%) while the FoM drops to approximately 35.4 RIU−1 (−9.9%) and increases to approximately , indicating a slight departure from the critical-coupling condition. The resonance angle shifts by approximately 0.6° per additional BP layer due to the additional optical path length introduced by the higher-index BP material.

These results indicate that the sensitivity is relatively robust to BP layer count (less than 3% variation) but that the FoM degrades measurably with each additional layer beyond the monolayer, motivating the use of optical contrast microscopy or Raman spectroscopy to verify monolayer identity prior to sensor assembly.

4.3.4 Franckeite overlayer thickness variation

For the Franckeite overlayer, the nominal modeled thickness is

nm, corresponding to approximately 1–2 unit cells of the Franckeite van der Waals structure (unit cell

-axis ≈1.7–1.9 nm). The tolerance analysis is conducted over the range:

  • nm (−0.5 nm, thinner flake)

  • nm (nominal)

  • nm (+0.5 nm, thicker flake)

Reducing to 1.3 nm decreases to approximately 304.1°/RIU (−2.8%) and the FoM to approximately 36.7 RIU−1 (−6.6%), while increases to approximately — the reduced Franckeite thickness provides less field concentration at the sensing interface, weakening the coupling efficiency. Increasing to 2.3 nm increases to approximately 318.2°/RIU (+1.7%) and the FoM to approximately 40.1 RIU−1 (+2.0%), with , indicating that a slightly thicker Franckeite layer marginally improves both metrics by increasing the absorptive field concentration without yet reaching the over-damped regime. This result is practically favorable: it suggests that a Franckeite thickness of 2.0–2.3 nm is slightly preferable to the nominal 1.8 nm from a performance standpoint, and that small over-thickness of the Franckeite layer does not penalize the sensor significantly.

4.3.5 Lateral uniformity and spatial sensitivity variance

The lateral uniformity of the 2D material flakes across the sensing area (∼1 mm2 for a standard Kretschmann SPR prism) is assessed through the concept of spatial sensitivity variance. If the Franckeite thickness varies by nm across the sensing area with a uniform spatial distribution, the resulting spatial variation in the local resonance angle is approximately , which is smaller than the FWHM of the resonance dip (∼8°) and therefore does not produce multiple resolvable resonances but instead broadens the measured dip by approximately 4% relative to the ideal uniform case. This effective linewidth broadening reduces the ensemble-averaged FoM by approximately 4%, bringing it to approximately 37.7 RIU−1 in the worst-case spatial inhomogeneity scenario—a value that remains substantially superior to the Cu-only reference (22.9 RIU−1).

To achieve the nominal 1.8 nm target thickness with nm lateral variation, we recommend the use of atomic force microscopy (AFM) in tapping mode to measure the Franckeite flake thickness profile across the transfer area prior to sensor assembly. Flakes identified to be within the 1.3–2.3 nm thickness range by AFM can be confidently used without significant performance degradation, while thicker few-layer flakes (>2.5 nm) should be discarded or re-exfoliated. For scalable production, chemical vapor deposition (CVD) or molecular beam epitaxy (MBE) routes for Franckeite thin film growth—which are actively being developed in the 2D materials community—would eventually replace mechanical exfoliation and provide the thickness control and lateral uniformity required for wafer-scale sensor fabrication.

5 Conclusion

This work has presented the design, electromagnetic optimization, and numerical performance characterization of a CaF2/Ag/Cu/BP/Franckeite multilayer SPR biosensor operating at nm. By combining the rigorous frequency-domain Maxwell wave equation with the characteristic transfer matrix method, a systematic parametric optimization of the Ag and Cu metallic layer thicknesses was performed, identifying the critical-coupling condition at nm and nm, where the resonance depth reaches . The fully optimized platform delivers a maximum angular sensitivity of 372°/RIU, a figure of merit of 47.0 RIU−1, and a detection accuracy of 0.128°−1 within the biologically relevant refractive-index window – RIU, surpassing the Cu-only reference configuration by approximately +62%, +78%, and +28% in sensitivity, FoM, and detection accuracy, respectively. Phase interrogation yields a substantially higher sensitivity of up to 29,200°/RIU, demonstrating the potential of phase-sensitive readout—with appropriate thermal compensation—to access sub-10−5 RIU detection limits.

The evanescent-field analysis confirms that the Ag/Cu bilayer extends the penetration depth to 178–201 nm, with a systematic 3–3.5 nm advantage over the Cu-only reference across the entire sensing window. The surface-sensitivity analysis developed in Section 4.4 projects a CEA detection limit below 1 ng/mL in the phase interrogation channel under the assumption of dual-channel thermal referencing and active temperature stabilization at K, placing the platform within the clinically actionable concentration range for colorectal cancer surveillance.

These numerical results constitute a theoretical basis for the proposed sensing architecture and represent the first step in a design-and-validation workflow. The following important caveats must be recognized. First, all performance figures reported in this study assume idealized optical constants and perfect layer uniformity; the size-dependent scattering correction analysis (Section 3.1.1) and the fabrication tolerance analysis (Section 2.3) show that realistic thin-film and exfoliation variations reduce the predicted FoM by approximately 5%–10% relative to the ideal case. Second, the long-term chemical durability of the Ag/Cu bilayer under repeated biological assay cycles—including exposure to PBS, serum, and mild regeneration buffers—has not been experimentally characterized, and no claim regarding point-of-care operability or clinical deployability is made on the basis of the present numerical analysis alone. Third, the BP and Franckeite surface functionalization protocols required to immobilize anti-CEA antibodies with the surface density and orientation assumed in the LOD model must be developed and validated experimentally. The claims made here are limited to the demonstrated theoretical performance advantages of the proposed multilayer architecture relative to the Cu-only reference and the benchmark literature configurations.

Future work will focus on: (i) experimental fabrication of the proposed stack by thermal evaporation of the Ag and Cu layers and mechanical transfer or CVD deposition of the BP and Franckeite overlayers, followed by spectroscopic ellipsometry characterization of the as-deposited optical constants; (ii) accelerated stability testing of the Ag/Cu bilayer under repeated exposure to PBS and simulated biological matrices over periods of 7–30 days, with optical monitoring of the SPR resonance position as a stability metric; (iii) development of anti-CEA antibody functionalization protocols on Franckeite surfaces and experimental validation of the surface-sensitivity model through CEA spiking experiments in buffer and diluted serum; (iv) construction of a temperature-controlled dual-channel phase-interrogation readout module and experimental measurement of the phase-channel noise floor under thermally compensated operating conditions; and (v) systematic investigation of the effects of BP layer number and crystallographic orientation on the anisotropy-enhanced field coupling to further optimize the sensing performance of the complete heterostructure.

Statements

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Author contributions

JW: Conceptualization, Formal Analysis, Funding acquisition, Investigation, Project administration, Resources, Software, Validation, Visualization, Writing – original draft, Writing – review and editing. TO: Conceptualization, Data curation, Funding acquisition, Investigation, Methodology, Resources, Software, Supervision, Visualization, Writing – original draft, Writing – review and editing.

Funding

The author(s) declared that financial support was not received for this work and/or its publication.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was used in the creation of this manuscript. AI-assisted language editing was used solely to improve grammar, clarity, and readability; all content was reviewed by the authors, who retain full responsibility for the manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1

    AlthuwaybA. A.Mani RajanM. S.AlzaidM.Arun KumarU.HassanH. M. A. (2026). Enhanced plasmonic response in a WS2–graphene–CNT-assisted kretschmann SPR biosensor for highly sensitive urine glucose quantification in clinical diagnostics. Microchem J.221, 117030. 10.1016/j.microc.2026.117030

  • 2

    AnbazhaganS.GnanamaniM. K.Arun KumarU.MandelaN. (2025). Machine learning-enhanced high-sensitivity hemoglobin detection using a Kretschmann-based SPR biosensor with optimized copper and silver layers. Chem. Eng. J.524, 169485. 10.1016/j.cej.2025.169485

  • 3

    BahadorH.IzadiyarH.NilghazA. (2026). A high-resolution metal–insulator–metal plasmonic biosensor with concentric ring resonators for carcinoembryonic antigen detection. Sci. Rep.16, 24226. 10.1038/s41598-026-55336-9

  • 4

    ChenP.SongY.XiaY. (2025a). Adaptively diagnosing system faults in microservice architecture: an autonomous predictive model construction framework. Future Gener. Comput. Syst.177, 108256. 10.1016/j.future.2025.108256

  • 5

    ChenJ.YinH.ZhangK.RenY.ZengH. (2025b). Integration of neural networks in brain–computer interface applications: research frontiers and trend analysis based on python. Eng. Appl. Artif. Intell.151, 110654. 10.1016/j.engappai.2025.110654

  • 6

    ChylekJ.CiprianD.HlubinaP. (2025). Thickness and wavelength optimizations of a high-performance SPR sensor employing a silver layer and Black phosphorus in principal directions. Nanomaterials15 (11), 790. 10.3390/nano15110790

  • 7

    CimingZ.YangL.ShuaiW.KeH.LinlinJ. (2026). A multiagent architecture of requirement-driven mechanical system optimization. J. Mech. Des.148 (12), 125001. 10.1115/1.4072148

  • 8

    DaiJ.NiP.SuK.ZhuJ.WuW.DuD. Z. (2026). Influence maximization in online social networks: models, algorithms, and trustworthy decision-making. Expert Syst. Appl.333, 134131. 10.1016/j.eswa.2026.134131

  • 9

    de Ponte RodriguesT. B.Diamantino MarquesD. A.Lopes CariaE. M.CorreiaV. P.BernardoC.JoãoJ. P.et al (2026). A model based on inhomogeneous waves to characterise kretschmann structures: application on biosensing. Nano-Struct Nano-Objects47, 101736. 10.1016/j.nanoso.2026.101736

  • 10

    FockaertL. I.WürgerT.UnbehauR.BoelenB.MeißnerR. H.LamakaS. V.et al (2020). ATR-FTIR in Kretschmann configuration integrated with electrochemical cell as in situ interfacial sensitive tool to study corrosion inhibitors for magnesium substrates. Electrochim Acta345, 136166. 10.1016/j.electacta.2020.136166

  • 11

    GaoZ.NiS.GuoG.XuY.LiH.MumtazS.et al (2026). Multi-lane merging control for vehicular platoons in 2-D planar with prescribed performance. IEEE Trans. Veh. Technol.75 (6), 9066–9079. 10.1109/tvt.2025.3639010

  • 12

    GuanX.YiuK. F. C.LiB.ZengY.ZhangR. (2025). 3D trajectory optimization for fixed-wing UAV communications with full UAV dynamics. IEEE Trans. Veh. Technol.74 (10), 15401–15415. 10.1109/tvt.2025.3570729

  • 13

    GuoR.YiJ.LuoX. (2025). An efficient classification and error correction knowledge distillation framework for remaining useful life prediction of bearings in air turbine starter. Neurocomputing657, 131611. 10.1016/j.neucom.2025.131611

  • 14

    HeJ.WuJ.NiJ.ZhangY.SiauK. L. (2025). Real-time task scheduling strategy for 3D printing cloud platforms in health scenes. Appl. Intell.55 (15), 1002. 10.1007/s10489-025-06907-2

  • 15

    HeY.ChengW.DengB.ZhangY.ChengL.WangY. (2026). SWS-YOLO: an energy-efficient spiking neural network for water-surface object detection. Neurocomputing696, 134066. 10.1016/j.neucom.2026.134066

  • 16

    JialingD. (2026). Unified group-aware influence maximization with generalized deep reinforcement learning. IEEE Trans. Netw.5555 (01), 1. 10.1109/TON.2026.3711960

  • 17

    JingJ.LiuK.JiangJ.XuT.WangS.MaJ.et al (2022). Performance improvement approaches for optical fiber SPR sensors and their sensing applications. Photonics Res.10 (1), 126. 10.1364/PRJ.439861

  • 18

    KanekoF.NakanoT.TerakadoM.ShinboK.KatoK.KawakamiT.et al (2002). Emission light from prism/silver/rhodamine-B LB film and multiple surface plasmon excitations in the ATR Kretschmann configuration. Mater Sci. Eng. C22 (2), 409–412. 10.1016/S0928-4931(02)00199-6

  • 19

    KhatunM. R.IslamM. S. (2026). Advances in PCF-SPR sensors: a comprehensive review of biosensing and environmental applications. Measurement258, 119226. 10.1016/j.measurement.2025.119226

  • 20

    KhodaieA.JavidanJ.HeidarzadehH. (2025). Development of a surface plasmon resonance sensor using 2D materials, including graphene and Black phosphorus, for measuring water pressure. Plasmonics20 (11), 9781–9792. 10.1007/s11468-025-03066-5

  • 21

    KuiriB.MondalR.KabiS.PatraA. S.MondalS. (2026). Thickness-optimized BK7/Ag/Ni/S-rich Zn-S chalcogenide multilayer Kretschmann SPR platform for aqueous refractive index sensing. Surf. Interfaces95, 109796. 10.1016/j.surfin.2026.109796

  • 22

    KumarR.SinghS.SarkarP.GariaL.KakarV. K.AlsubaieA. S.et al (2025). Sensitivity enhancement of franckeite-based surface plasmon resonance sensors using a bimetallic structure. Plasmonics20 (4), 2049–2056. 10.1007/s11468-024-02432-z

  • 23

    LiX.HuangZ.LiuY.WangY. (2026). Accelerating outlier-robust point cloud registration by known gravity directions. IEEE Trans. Autom. Sci. Eng.23, 2310–2323. 10.1109/tase.2026.3652579

  • 24

    LiangY.HuangQ.WangL.XuH. (2026). Effects of consolidation on the effective reinforcement zone in GDL-clay systems. Transp. Geotech.62, 102164. 10.1016/j.trgeo.2026.102164

  • 25

    LiuY.WangY.FengY.WuY. (2022). Neural network-based adaptive boundary control of a flexible riser with input deadzone and output constraint. IEEE Trans. Cybern.52 (12), 13120–13128. 10.1109/tcyb.2021.3102160

  • 26

    LiuJ.MaC.LiM.HeJ.TotisG.HuaC.et al (2025). A real-time spatiotemporal error compensation framework for face gear grinding. Eng. Appl. Artif. Intell.162, 112429. 10.1016/j.engappai.2025.112429

  • 27

    LuY.SongX.ZhuH. (2026). DFSA-Net: an effective single image dehazing framework via frequency-domain processing and multi-scale representation learning. Expert Syst. Appl.306, 130853. 10.1016/j.eswa.2025.130853

  • 28

    MengF.XuH.GaoZ.LiQ. (2026). Real-time trajectory planning of unmanned surface vehicles: a constraint-embedded model predictive control approach. Ocean. Eng.363, 126812. 10.1016/j.oceaneng.2026.126812

  • 29

    NaraokaR.OkawaH.HashimotoK.KajikawaK. (2005). Surface plasmon resonance enhanced second-harmonic generation in Kretschmann configuration. Opt. Commun.248 (1–3), 249–256. 10.1016/j.optcom.2004.11.094

  • 30

    NasrN.ShafiM.ZhaoT.AliR.AhmadI.KhanM.et al (2024). A two-fold SPR-SERS sensor utilizing gold nanoparticles and graphene thin membrane as a spacer in a 3D composite structure. Spectrochim. Acta A Mol. Biomol. Spectrosc.304, 123331. 10.1016/j.saa.2023.123331

  • 31

    NiW.WuK.WangL.ZhangC.PengZ.TangR.et al (2026). A method for quantifying feeding behavior of grass carp in outdoor ponds with complex backgrounds. Comput. Electron Agric.251, 112077. 10.1016/j.compag.2026.112077

  • 32

    NiuS.WangJ.LiZ.LiuZ.ZhaoJ.SunZ. (2026). Command filter and neural network-based fixed-time backstepping control of electro-hydraulic system with uncertainties. Appl. Math. Model157, 116848. 10.1016/j.apm.2026.116848

  • 33

    RamkumarR. M. (2026). Refractive index-based hemoglobin detection using a multilayer BP/Au/Ag Kretschmann-configured surface plasmon resonance biosensor: a computational and machine learning-assisted approach. Microchem J.228, 119116. 10.1016/j.microc.2026.119116

  • 34

    RishiP.KuzhaloliS.ManimegalaiR.Sunitha RamC.AnushkannanN. K. (2026). Optimized graphene–silver multilayer Kretschmann SPR biosensor for high-sensitivity visible-wavelength refractive index detection in biomedical applications. Sens. Biosensing Res.52, 101020. 10.1016/j.sbsr.2026.101020

  • 35

    RojasA.SunL.ZhaoX.LiuY. (2026). Quasi-symplectic ADRC hybridization to stabilize a flexible truss for a space telescope. Aerosp. Sci. Technol.176, 112085. 10.1016/j.ast.2026.112085

  • 36

    SantosD. F.GuerreiroA.BaptistaJ. M. (2015). SPR microstructured D-type optical fiber sensor configuration for refractive index measurement. IEEE Sens. J.15 (10), 5472–5477. 10.1109/JSEN.2015.2442335

  • 37

    SathiyaR.LingayatN.GopinathS.AnandaramH.Arun KumarU. (2026). Numerical design of a Kretschmann-configured multilayer SPR sensor with bismuth germanate dielectrics for high-sensitivity non-invasive glucose monitoring in diabetes management. Sens. Biosensing Res.51, 100996. 10.1016/j.sbsr.2026.100996

  • 38

    SelfiA. D.SantjojoDJDHTresnaW. P.HarunS. W. (2026). Masruroh. Enhanced SPR sensor characteristics and performance via TiO2/CQDs nanocomposite functionalization of D-shaped fiber optic SPR sensor for highly sensitive interleukin-17 detection. Talanta Open13, 100654. 10.1016/j.talo.2026.100654

  • 39

    ShiJ.HanD.ChenC.ShenX. (2024). KTMN: Knowledge-driven two-stage modulation network for visual question answering. Multimed. Syst.30 (6), 350. 10.1007/s00530-024-01568-6

  • 40

    ShivanganiS. A.KumarD.KumarB.GuptaS. K. (2024). Design and analysis of SPR-based refractive index sensor with enhanced sensitivity based on graphene/BP heterostructure. Opt. Quantum Electron56 (8), 1–21. 10.1007/s11082-024-06933-3

  • 41

    SinghA. B.BashaA. A.Arun KumarU.MubarakaliA. (2026). Multilayer Ag–Au–BP–TIBr–FASnI3 Kretschmann surface plasmon resonance biosensor for high sensitivity refractive index analysis: a computational and machine learning approach. Anal. Chim. Acta1384, 344991. 10.1016/j.aca.2025.344991

  • 42

    SunM.SongY.WuH.WangQ. (2023). Design and simulation of Au/SiO2 nanospheres based on SPR refractive index sensor. Sensors23 (6), 3163. 10.3390/s23063163

  • 43

    SunY.DaiJ.GongL.GaoB.LinG.ChenJ.et al (2026). CaMT: class-aware Multi-level training distillation for lightweight semantic segmentation in apple orchard. Artif. Intell. Agric.10.1016/j.aiia.2026.08.001

  • 44

    TangX.ChenQ.WengW.JinC.LiuZ.WangJ.et al (2026). Task assignment and exploration optimization for low altitude UAV rescue via generative AI enhanced multi-agent reinforcement learning. IEEE Trans. Mob. Comput.25 (1), 627–643. 10.1109/TMC.2025.3594188

  • 45

    TeneT.BorjaM.SánchezN.Arias PolancoM.CaputiL. S.StrafaceS.et al (2026a). Optimized nanomaterial-based SPR sensor for urine glucose detection at low concentrations. Sens. Actuators Rep.11, 100467. 10.1016/j.snr.2026.100467

  • 46

    TeneT.Dávalos VillegasM. X.Vacacela GomezC. (2026b). Modeling an SPR sensor for carcinoma-related refractive-index detection: the case of CaF2/Au/Si3N4/BP multilayer system. Biosensors16 (4), 198. 10.3390/bios16040198

  • 47

    WanA.ZhuZ.Al-BukhaitiK.YinR.YuanJ.ChengX.et al (2026a). Digital twin framework for interpretable aero-engine RUL prediction via multibranch LSTM and Unity visualization. IEEE Trans. Reliab75, 1709–1719. 10.1109/TR.2026.3686412

  • 48

    WanA.GaoY.LiuW.YinR.Al-BukhaitiK. (2026b). Real-time optimization of vertical roller mills using XGBoost prediction and Q-Learning control. Comput. Mater Contin.88 (2), 1–10. 10.32604/cmc.2026.081719

  • 49

    WangS.DuanF.WangE. (2024). Study on the design method of an automatic outrigger layout control system for variable outrigger layout trimaran. Ocean. Eng.291, 116465. 10.1016/j.oceaneng.2023.116465

  • 50

    WangQ.ChenX.AnQ.ChenM.XuB.GuoH.et al (2025a). Research on the method for improving the cutting performance of forming tools based on the non-uniform passivation of the cutting edge. Int. J. Adv. Manuf. Technol.138 (9), 3975–3987. 10.1007/s00170-025-15719-0

  • 51

    WangZ.ZhangX.LiW.FengZ. (2025b). Real-time UUV obstacle avoidance through flexible steering technology based on improved soft actor-critic framework. IEEE Trans. Instrum. Meas.74, 1–14. 10.1109/tim.2025.3612643

  • 52

    WangX.ZhangS.ZhangY.YinC.ChenH. (2026a). Frequency-domain demodulated SPR-MZI fiber sensor for decoupled measurements of salinity and temperature in seawater. Sens. Actuators B Chem.465, 140229. 10.1016/j.snb.2026.140229

  • 53

    WangZ.TaoY.ZhangS.LiuX.LinY.LiL.et al (2026b). Spatial spiral tube multi-roller bending: accurate axial prediction utilizing AWPSO-FECAM-LSTM framework. Expert Syst. Appl.296, 128960. 10.1016/j.eswa.2025.128960

  • 54

    WangD.DuL.LiZ.ChengN.SiJ.ShenW. (2026c). WPMNet: weight pruning and parameter quantization assisted multi-scale lightweight network for interference recognition. IEEE Trans. Cogn. Commun. Netw.12, 1313–1326. 10.1109/TCCN.2025.3614368

  • 55

    WangQ.YinZ.HeY.WangS.ChenX.ZhangC. (2026d). Process optimization of electrolytic-assisted milling for titanium alloy based on numerical simulation and experimental study. Int. J. Adv. Manuf. Technol.144, 6365–6384. 10.1007/s00170-026-18233-z

  • 56

    WangL.GuoM.ChenZ.ZhangX.WangW.LiuX.et al (2026e). Changes in soil TN and TP induced by freeze-thaw effect and the driving mechanism of environmental factors in a small watershed. Int. Soil Water Conserv. Res.14 (2), 100609. 10.1016/j.iswcr.2026.01.001

  • 57

    WangL.GuoS.GeT.ManclK. M.HijriM.IseriY.et al (2026f). Plastic mulch productivity-sustainability tradeoffs and pathways toward an eco-friendly framework: insights from a global meta-analysis. Nat. Commun.17 (1), 1924. 10.1038/s41467-026-68798-2

  • 58

    WekalaoJ.MandelaN.MuhekiJ.ZaidA. (2025a). Design and analysis of a terahertz metasurface-based refractive index sensor for hemoglobin detection with behaviour prediction using polynomial regression. Plasmonics20 (4), 2123–2152. 10.1007/s11468-024-02445-8

  • 59

    WekalaoJ.KoukiM.Ben KhalifaS.UA. K.ChebaaneS.PatelS. K. (2025b). Plasmon-enhanced charge transport in graphene-Au-SiO2 metasurfaces for terahertz biosensor applications. Plasmonics21, 1–11. 10.1007/s11468-025-02945-1

  • 60

    WekalaoJ.MuhekiJ.MandelaN.KabarokoleP.MakoyeP. (2025c). Machine learning-optimized titanium-based broadband absorber with high-efficiency performance across visible and infrared wavelengths. Opt. Quantum Electron.57 (2), 129. 10.1007/s11082-025-08046-x

  • 61

    WuY.FanL.LiB.WeiY.GuY.WangJ. (2025). Establishment of a modelica model for flow metering valve controlled pump and analysis on delivery and leakage characteristics. Energy339, 139034. 10.1016/j.energy.2025.139034

  • 62

    XieZ.MoC.JiaB. (2026). CDAF: a co-evolutionary decoupled attention framework for explainable weak thermal fault diagnosis of marine diesel engines. Sci. Rep.16 (1), 17459. 10.1038/s41598-026-46425-w

  • 63

    YaoX.XuX.HeW.LiuY. (2025). Asymptotical event-based input-output constrained boundary control of flexible manipulator agents under a signed digraph. Sci. China Inf. Sci.68 (4), 142201. 10.1007/s11432-024-4293-3

  • 64

    YaoX.LiX.LiuZ.GaoH.LiJ.LiuY. (2026). Asymptotical fault-tolerant time-varying tracking control of networked Mobile flexible manipulators under prescribed performances and DoS attacks. IEEE Trans. Autom. Control71 (1), 20–35. 10.1109/tac.2025.3583101

  • 65

    YuanJ.ZhouL.HeM.LuoC.ZhangJ. (2026). A lightweight dual path Kolmogorov-Arnold convolution network for medical optical image segmentation. Neurocomputing659, 131776. 10.1016/j.neucom.2025.131776

  • 66

    ZahmatkeshanH.KarimiM. J.SadeghiM.AdelpourZ. (2025). Investigation and optimization of the sensitivity in a franckeite-based biosensor with bimetallic layers. Plasmonics20 (9), 7803–7813. 10.1007/s11468-025-02822-x

  • 67

    ZangZ.XiangS.KhaniA.MilaniS.ZuorroA. (2026). Numerical investigation of interaction between internal mixing air and spray of three kinds of fluids. Therm. Sci.30 (1 Part B), 629–641. 10.2298/tsci250315139z

  • 68

    ZhengS.LiuZ.ZhuZ.ZhangX.LiJ.ZhaoY. (2026). BiKT: unleashing the potential of GNNs via Bi-Directional knowledge transfer. IEEE Trans. Pattern Anal. Mach. Intell.48 (3), 3304–3318. 10.1109/TPAMI.2025.3636549

  • 69

    ZhouZ.WangY.LiuX.LiZ.WuM.ZhouG. (2025). Hybrid of neural network and physics-based estimator for vehicle longitudinal dynamics modelling using limited driving data. IEEE Trans. Intell. Transp. Syst.26 (10), 16735–16746. 10.1109/TITS.2025.3585346

  • 70

    ZhouY.CaoP.ChenS.YuH.QuanX. (2026). Cu/In interfacial proton relay enables efficient CO2-to-ethanol photoreduction in a ternary heterojunction. J. Colloid Interface Sci.719, 140585. 10.1016/j.jcis.2026.140585

Summary

Keywords

Ag/Cu bilayer, angular sensitivity, black phosphorus, Franckeite, optical biosensor, surface plasmon resonance, transfer matrix method, carcinoembryonic antigen

Citation

Wekalao J and Otieno T (2026) Design and optimization of an Ag/Cu–black phosphorus/Franckeite heterostructure for high-sensitivity surface plasmon resonance biosensing. Front. Mater. 13:1919005. doi: 10.3389/fmats.2026.1919005

Received

25 June 2026

Revised

09 September 2026

Accepted

18 September 2026

Published

16 October 2026

Volume

13 - 2026

Edited by

Mahmoud Hamdy Elshorbagy, Minia University, Egypt

Reviewed by

Dharmendra Kumar, Guru Ghasidas Vishwavidyalaya, India

Bartosz Janaszek, Warsaw University of Technology, Poland

Updates

Copyright

*Correspondence: Jacob Wekalao, , ; Tobias Otieno,

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics