Abstract
Reliable metallization of polymer substrates is essential for flexible electronics, advanced packaging, and high-frequency systems, yet achieving strong metal/polymer adhesion while maintaining good electrical performance remains challenging. Here, carbon-ion, nitrogen-ion, and carbon/nitrogen dual-ion implantation were used to modify polyimide, with the implantation conditions independently adjusted to obtain nearly identical surface free energies of 46.43–47.22 mJ m-2. Despite the similar wettability, the resulting copper/polyimide peel strengths differed substantially, reaching 0.14, 0.20, and 1.63 N mm-1 for the carbon-, nitrogen-, and carbon/nitrogen-treated samples, respectively, while the corresponding copper-film sheet resistances were 20, 14, and 17 mΩ/□. Scanning electron microscopy showed little microscale morphological variation, whereas atomic force microscopy revealed distinct nanoscale roughening among the implantation conditions. X-ray photoelectron spectroscopy, attenuated-total-reflection Fourier-transform infrared spectroscopy, and Raman spectroscopy further identified distinct implantation-induced chemical and aromatic-framework reconstruction states. In particular, carbon/nitrogen implantation produced the highest nanoscale roughness and strongest copper adhesion, whereas nitrogen implantation yielded the lowest sheet resistance. Despite nearly matched surface free energies, the three implantation conditions therefore produced markedly different Cu/PI adhesion. The contrast between the highest adhesion after C/N treatment and the lowest sheet resistance after N treatment indicates that interfacial adhesion and Cu-film electrical continuity are associated with different features of the implantation-induced reconstructed surface state.
1 Introduction
Polyimide (PI) is a high-performance polymer widely used in flexible circuits, microelectronic interconnects, advanced packaging, sensors, and high-frequency electronic systems because it combines thermal stability, dimensional stability, mechanical flexibility, dielectric performance, and chemical resistance. Molecular design and composite modification have further expanded the use of PI in high-frequency electronics by reducing dielectric constant and dielectric loss while retaining useful mechanical properties (; ). PI composites have also been evaluated under hydrogen tribological conditions, illustrating continuing interest in PI for demanding service environments (). These applications increasingly require reliable integration of PI with conductive Cu patterns or films. Interface-engineered Cu/PI bilayers have been demonstrated for miniaturized flexible circuits with high interfacial adhesion (), while laser-assisted electroless metallization has been used to fabricate PI-based 5G/Sub-6 GHz antennas with good electrical performance after cyclic bending (). Plasma-enabled additive Cu plating on PI likewise highlights the need to overcome the inherent surface inertness and low surface energy of the polymer before metallization (). Thus, insufficient Cu/PI interfacial adhesion remains a central challenge for high-reliability flexible electronics.
A variety of dry surface-modification approaches have been developed to activate polymer surfaces before metallization. Plasma pretreatment of PI can simultaneously increase roughness and surface energy, introduce chemically active groups, and alter subsequent Cu-film nucleation and densification (). Pulse-modulated atmospheric-pressure plasma treatment has also been shown to introduce oxygen-containing groups into PI while increasing Cu peel strength; however, excessive treatment can damage the polymer structure and reduce the adhesion benefit (). On PET, mixed C/Cu plasma pretreatment produces an in situ C/Cu transition layer through polymer-chain activation, radical reactions, and Cu-containing interfacial species, demonstrating that a deliberately reconstructed interphase can be more important than simple surface activation (). Ion implantation provides an additional route in which ion species, energy, fluence, and temperature can be controlled. Dose-dependent N+ implantation of PTFE has been reported to produce progressively different structural states, including irradiation-induced structural modification, sputtering/roughening, and C=C-rich carbonized structures as treatment severity increases ().
These studies also illustrate a major difficulty in identifying the true controlling factor for metal/polymer adhesion: surface free energy, roughness, functional-group chemistry, and damage state generally evolve at the same time. found that Ar-N2 plasma treatment increased PI roughness and surface energy while generating C-N-containing surface states and improving Cu adhesion. similarly showed that wettability, roughness, oxygen-containing groups, and peel strength changed concurrently and that over-treatment reduced the adhesion after an optimum treatment time. Consequently, a conventional comparison in which all surface descriptors change simultaneously cannot determine whether adhesion is controlled primarily by wettability, roughness, or the microscopic structure of the reconstructed interphase.
Spectroscopic interpretation is another important issue. Chemical or thermal degradation of PI can generate carbon-rich structures, but the Raman response of aromatic PI is not equivalent to that of a simple graphitic carbon material. used combined FTIR and Raman analyses to distinguish intact PI from amorphous carbon formed by PI degradation, while also noting that characteristic graphitic D- and G-type features are not necessarily observed when degradation is absent. Conversely, showed that a deliberately formed carbonaceous C/Cu interlayer can display pronounced sp2-rich carbon evolution. These observations indicate that Raman features in the conventional D/G region should be interpreted together with the residual polymer fingerprint and complementary chemical evidence rather than by applying a universal I_D/I_G criterion to PI.
The chemical role of the incident species must therefore be considered together with irradiation damage. C and N are particularly suitable for the present mechanistic comparison because both are constituent elements of the PI molecular framework and do not introduce metallic contamination. N-containing plasma treatment of PI has been reported to generate new C-N-related bonding environments that correlate with improved Cu adhesion and denser Cu growth (), whereas N+ implantation of PTFE demonstrates that increasing ion dose can eventually drive extensive bond scission, sputtering, C=C formation, and carbonization (). Different C-, N-, and C/N-based implantation conditions can generate distinct balances between collision-induced damage and chemical reconstruction. Their comparison therefore provides a practical basis for examining whether the resulting reconstructed states are simply additive or whether a distinct cooperative state can be produced.
In the present work, untreated PI is compared with C-ion-implanted PI, N-ion-implanted PI, and C/N dual-ion-co-implanted PI. Importantly, the implantation parameters were independently adjusted so that the three ion-modified surfaces exhibited nearly identical total surface free energies. This experimental strategy intentionally suppresses differences in macroscopic wettability and provides a controlled platform for comparing the reconstructed surface states generated under different implantation conditions when the conventional surface-energy descriptor is essentially matched.
Surface free energy, SEM, AFM, XPS, ATR-FTIR, and Raman spectroscopy were combined to characterize surface energetics, nanoscale morphology, elemental composition, chemical bonding, molecular-framework damage, and aromatic/conjugated structural reorganization. Cu films were subsequently deposited under identical conditions, followed by peel-strength and sheet-resistance measurements. The objective is to determine how the distinct implantation-induced surface states correlate with Cu/PI adhesion and Cu-film electrical performance under nearly matched surface-energy conditions.
2 Materials and methods
2.1 Polyimide substrates and ion implantation
Commercial PI films with a thickness of 25 μm were cut into specimens measuring 30 cm × 30 cm. Before metallization, the PI specimens were ultrasonically cleaned in ethanol for 15 min, dried with nitrogen, and fixed on the substrate holder in the vacuum chamber.
Four surface conditions were investigated: untreated PI, C-ion-implanted PI (6#C), N-ion-implanted PI (19#N), and C/N dual-ion-co-implanted PI (11#C/N). The ion-implantation parameters and corresponding sample codes are summarized in Table 1.
TABLE 1
| Sample | Ion species | Ion energy/KeV | Fluence/ion cm-2 | Treatment mode |
|---|---|---|---|---|
| Untreated PI | — | — | — | — |
| 6#C | C | 20 | 5 × 1015 | C Implantation |
| 19#N | N | 25 | 5 × 1015 | N implantation |
| 11#C/N | C + N | 15/8 | 5 × 1015/5 × 1015 | Dual-ion-co-implantation |
Ion-implantation conditions and sample codes.
Unlike a conventional ion-species comparison using identical nominal implantation parameters, the ion energy, fluence, and/or other implantation parameters were independently adjusted in the present work to obtain approximately matched final surface free energies. This design was adopted specifically to compare implantation-induced microscopic reconstruction while minimizing macroscopic differences in surface wettability.
Because the implantation parameters were deliberately different among the three modified samples, the present comparison should not be interpreted as a strictly single-variable ion-species study. Accordingly, the subsequent discussion focuses on the final reconstructed surface states generated under the different implantation conditions rather than attributing the observed differences solely to the elemental identity of the incident ions.
2.2 Surface free-energy measurement
Surface free energy was determined from contact-angle measurements using deionized water and diiodomethane as probe liquids. For each sample, the contact angle of each probe liquid was measured three times (n = 3). For each replicate set, the dispersive and polar components of the surface free energy were calculated using the Owens-Wendt two-liquid method (). The three calculated surface-free-energy values were then averaged, and the final results are reported as mean ± SD.where γsd and γsᵖ are the dispersive and polar components, respectively.
All samples were measured using identical stabilization and fitting procedures. Static contact angles were measured using a goniometer (DropMeter A-200, United States of America) with 3 μL droplets of both deionized water and diiodomethane. All characterizations were performed at room temperature, and the samples were sealed and stored before testing.
2.3 Cu metallization
Cu films were deposited onto the untreated and ion-modified PI samples using direct-current magnetron sputtering at a power of 1 kW for 20 min. The Cu thickness was 2 μm, and the deposition pressure, deposition rate, substrate temperature, source power, and other deposition conditions were kept identical for all samples.
2.4 Surface morphology and spectroscopic characterization
Surface morphology was examined by scanning electron microscopy using a field-emission SEM (FE-SEM, ZEISS Sigma 300, Germany) at an operating voltage of 5 kV.
AFM was performed using an atomic force microscope (Dimension Edge, Bruker) over a scan area of 10 μm × 10 μm. The arithmetic mean roughness S_a, root-mean-square roughness S_q, maximum height, and minimum height were extracted using the same post-processing procedure. Three representative surface areas were selected on each 30 cm × 30 cm sample (n = 3), and each area was scanned over 10 μm × 10 μm. The roughness parameters obtained from the three independent measurement areas are reported as mean ± SD.
XPS measurements were performed using an X-ray photoelectron spectrometer (K-Alpha, Thermo Fisher Scientific, United States of America) equipped with an Al Kα source. Both survey spectra and high-resolution C 1s, N 1s, and O 1s spectra were collected. High-resolution spectra were recorded at an energy step of 0.1 eV with a pass energy of 50 eV, and binding energies were calibrated by referencing to the C–C/C=C component of C 1s set at 284.8 eV.
For XPS data processing, after calibrating binding energies with the C–C/C=C component of C 1s at 284.8 eV, the instrument-exported Smart background was adopted, with a small additional linear residual correction applied when necessary, and pseudo-Voigt GL (30) line shapes were used consistently across all fittings. The fitting strategies for C 1s, N 1s, and O 1s spectra have also been clarified to improve result reproducibility.
Because the C–N and C–O contributions strongly overlap at the present experimental resolution, the C 1s envelope was quantified using three representative components: C–C/C=C, a combined C–N/C–O envelope, and imide-carbonyl O=C–N. Weak π–π* shake-up intensity was not included in the principal component-area comparison. N 1s spectra were analyzed using two comparative envelopes, while O 1s spectra were resolved into C=O- and C–O-related contributions.
ATR-FTIR spectra were recorded using a Nicolet iS50 spectrometer equipped with an attenuated total reflection (ATR) accessory over the range of 4,000–400 cm-1 at a resolution of 4 cm-1. Each spectrum was averaged over 32 scans.
Raman spectra were recorded using a LabRAM HR Evolution Raman spectrometer with an excitation wavelength of 405 nm and a laser power of 1.5 mW over the spectral range of 90–3,500 cm-1.
2.5 Adhesion and electrical measurements
The overall peel-strength specimen size was 200 mm × 10 mm, and the effective Cu peel-strip width was 3 mm. To prevent tearing of the ultrathin Cu layer during peeling, the Cu layer of all sample groups was thickened to 18 μm using the same electroplating process. The peel test was performed according to IPC-TM-650 2.4.9 E. The PI substrate was fixed in the test fixture, and one end of the metal layer was pre-separated to serve as the gripping tab. Continuous peeling was carried out at a peel angle of 180° and a crosshead speed of 100 mm min-1 while the load–displacement curve was recorded. Peel strength was calculated as the ratio of the mean load in the steady-state peeling region to the effective peel-strip width (3 mm). Five independent specimens were tested for each condition (n = 5), and the results are reported as mean ± standard deviation (SD) in N mm-1.
Cu-film sheet resistance was measured using an RTS-5 four-point-probe tester and is reported in mΩ/□. Five measurement positions were selected across each 30 cm × 30 cm sample using a uniformly distributed sampling scheme (n = 5). The sheet resistance at each position was recorded, and the final result is reported as mean ± SD.
3 Results and discussion
3.1 Matched surface free energy and strongly contrasting Cu/PI adhesion
The surface free energy and its dispersive and polar components are summarized in Table 2 and Figure 1.
TABLE 2
| Sample | θW (°) | θDII (°) | Total SFE (mJ m-2) | Dispersive component (mJ m-2) | Polar component (mJ m-2) | Polar fraction (%) |
|---|---|---|---|---|---|---|
| Untreated PI | 76.80 ± 0.75 | 26.30 ± 0.61 | 46.27 ± 0.33 | 42.21 ± 0.19 | 4.05 ± 0.25 | 8.8 |
| 6#C | 70.53 ± 0.45 | 29.90 ± 0.64 | 47.05 ± 0.35 | 39.96 ± 0.22 | 7.09 ± 0.15 | 15.1 |
| 19#N | 70.05 ± 0.51 | 32.47 ± 0.68 | 46.43 ± 0.41 | 38.79 ± 0.25 | 7.64 ± 0.17 | 16.5 |
| 11#C/N | 69.98 ± 0.67 | 30.00 ± 0.60 | 47.22 ± 0.43 | 39.85 ± 0.18 | 7.37 ± 0.26 | 15.6 |
Surface free energy and its dispersive and polar components for untreated and ion-modified PI (mean ± SD, n = 3).
All relative standard deviations (RSDs) were ≤6.2%. θW and θDII, denote the water and diiodomethane contact angles, respectively.
FIGURE 1
The total surface free energies of the three implanted samples lie within a narrow range of 46.43–47.22 mJ m-2, corresponding to a maximum spread of only 0.80 mJ m-2. The macroscopic surface energetics of the three modified surfaces can therefore be regarded as effectively matched.
Ion implantation nevertheless changes the nature of the surface energy. The polar component increases from only 4.05 mJ m-2 for untreated PI to 7.09, 7.64, and 7.37 mJ m-2 after C, N, and C/N implantation, respectively. Correspondingly, the polar fraction approximately doubles from 8.8% to 15.1%–16.5%.
Despite their nearly identical total surface free energies and closely clustered polar components, the three implanted samples exhibit dramatically different Cu/PI adhesion. The peel strengths are 0.14 N mm-1 for C implantation, 0.20 N mm-1 for N implantation, and 1.63 N mm-1 for C/N co-implantation. Accordingly, the C/N condition provides approximately 11.6 times the adhesion of the C-treated surface and 8.2 times that of the N-treated surface.
This controlled comparison provides direct evidence that neither total surface free energy nor its polar component is sufficient to predict Cu/PI adhesion. In particular, the N-treated sample exhibits the highest polar component, 7.64 mJ m-2, but only modest adhesion. This differs from studies in which plasma-induced increases in surface energy occurred together with chemical functionalization and roughening and therefore correlated positively with adhesion (; ). By deliberately matching the final surface free energy, the present experiment shows that the large adhesion difference must instead be sought in the microscopic morphology and chemical/structural state of the reconstructed PI surface.
3.2 AFM and SEM: nanoscale roughening without severe microscale damage
AFM revealed pronounced nanoscale differences, as summarized in Table 3 and Figure 2.
TABLE 3
| Sample | Sq (nm) | Sa (nm) | Maximum (nm) | Minimum (nm) | Relative sq (vs. Untreated PI) |
|---|---|---|---|---|---|
| Untreated PI | 1.90 ± 0.26 | 1.30 ± 0.17 | 9.70 ± 1.56 | −11.00 ± 2.00 | 1.00 ± 0.14 |
| 6#C | 4.61 ± 0.41 | 3.40 ± 0.12 | 38.00 ± 11.43 | −19.00 ± 2.09 | 2.43 ± 0.22 |
| 19#N | 2.89 ± 0.30 | 2.13 ± 0.26 | 22.80 ± 3.75 | −10.00 ± 2.00 | 1.52 ± 0.16 |
| 11#C/N | 5.34 ± 0.62 | 3.92 ± 0.88 | 73.03 ± 7.78 | −22.07 ± 10.71 | 2.81 ± 0.33 |
AFM surface-topography parameters of untreated and ion-implanted PI (mean ± SD, n = 3).
Relative Sq was calculated by normalizing each measured Sq value to the mean Sq of untreated PI (1.90 nm).
FIGURE 2
Ion implantation increases S_q from 1.90 nm for untreated PI to 4.60 nm for C implantation, 2.89 nm for N implantation, and 5.34 nm for C/N co-implantation. The C/N condition therefore produces the greatest nanoscale roughening and the largest positive height excursion.
Greater roughness can increase the true contact area and provide additional topographical sites for mechanical anchoring of deposited Cu. Plasma-treated PI has indeed been reported to exhibit improved adhesion together with increased roughness and nanoscale surface features (). However, excessive roughening can also promote local stress concentration during peeling, as suggested for over-treated PI (). In the present samples, roughness alone cannot explain the adhesion trend: C-treated PI already has an S_q of 4.60 nm, close to the 5.34 nm of C/N-treated PI, but its peel strength is only 0.14 N mm-1 compared with 1.63 N mm-1 for C/N treatment. Nanoscale roughness is therefore a contributing but non-sufficient condition for strong Cu/PI adhesion.
SEM observations (Figure 3) show that all four PI surfaces remain macroscopically continuous after implantation, without obvious large cracks, severe etching pits, or other signs of catastrophic irradiation damage. The untreated PI exhibits a relatively smooth and uniform surface. After C implantation, only subtle changes in local surface texture are observed, consistent with the limited chemical reconstruction indicated by XPS and ATR-FTIR. The N-implanted surface also retains overall continuity, although slightly more heterogeneous local features can be distinguished, in agreement with the stronger chemical and molecular reconstruction revealed by XPS and ATR-FTIR. The C/N-co-implanted surface shows a similarly intact microscale morphology, despite exhibiting the highest nanoscale roughness in the AFM measurements. These observations indicate that the principal morphology differences among the treatments occur at the nanoscale rather than through severe microscale damage. SEM therefore establishes overall surface continuity, whereas AFM resolves the treatment-dependent nanoscale roughening used in the subsequent structure–property analysis.
FIGURE 3
3.3 Implantation-induced chemical reconstruction revealed by XPS
3.3.1 Survey spectra and elemental composition
The elemental compositions derived from XPS survey spectra are listed in Table 4, while the survey and high-resolution spectra are reserved for Figure 4.
TABLE 4
| Sample | C (at%) | N (at%) | O (at%) | N/C | O/C |
|---|---|---|---|---|---|
| Untreated PI | 89.34 | 5.65 | 5.01 | 0.0632 | 0.0561 |
| 6#C | 89.19 | 5.73 | 5.08 | 0.0642 | 0.0570 |
| 19#N | 94.09 | 4.32 | 1.59 | 0.0459 | 0.0169 |
| 11#C/N | 88.87 | 5.61 | 5.52 | 0.0631 | 0.0621 |
Surface elemental compositions obtained from XPS survey spectra.
C implantation causes little net elemental redistribution. The C, N, and O concentrations remain close to those of untreated PI.
FIGURE 4
N implantation produces a fundamentally different state. The C concentration increases from 89.34 to 94.09 at%, while O decreases from 5.01 to only 1.59 at%. The O/C ratio consequently decreases from 0.0561 to 0.0169. The N concentration also decreases from 5.65 to 4.32 at%, despite implantation with nitrogen ions.
The compositional response also shows that the implanted ion species cannot be equated directly with the final surface elemental composition. Energetic-ion bombardment simultaneously causes bond cleavage, volatile-fragment release, preferential sputtering, atomic recoil, implantation, and subsequent chemical recombination. A comparable non-monotonic response has been reported for N+ implantation of PTFE: low doses modified structural order, intermediate doses were dominated by sputter loss and roughening, and high doses generated C=C-rich carbonized structures (). Under the present PI conditions, N implantation therefore produces substantial heteroatom depletion and carbon enrichment rather than simple nitrogen enrichment.
The C/N-co-implanted surface is markedly different from the N-only surface. Its C, N, and O concentrations remain close to untreated PI, and the oxygen concentration is 5.52 at%. Dual-ion implantation therefore does not reproduce the severe deoxygenation produced by N implantation alone, demonstrating that the C/N response is not a simple additive superposition of the two single-ion treatments.
3.3.2 C 1s spectra
Because C–N and C–O contributions strongly overlap at the current spectral resolution, the C 1s spectra were quantitatively compared using three chemically representative components: a low-binding-energy C–C/C=C component associated mainly with aromatic and carbon-rich carbon, a combined C–N/C–O envelope, and a higher-binding-energy imide-carbony O=C–N component. The C 1s high-resolution fitting results are shown in Table 5.
TABLE 5
| Sample | C–C/C=C (%) | C–N/C–O (%) | Imide C=O (%) |
|---|---|---|---|
| Untreated PI | 42.34 | 49.47 | 8.19 |
| 6#C | 43.80 | 48.27 | 7.93 |
| 19#N | 51.61 | 43.75 | 4.64 |
| 11#C/N | 43.21 | 48.34 | 8.45 |
C 1s high-resolution fitting results. Area fractions are relative within the C 1s envelope.
The C-treated surface shows only modest redistribution. The C–C/C=C fraction increases from 42.34% to 43.80%, while the imide-carbonyl contribution changes only slightly from 8.19% to 7.93%. This agrees with the survey spectra and indicates that C implantation causes local structural rearrangement without extensive destruction of the overall PI, chemical framework.
N implantation gives the largest modification. The C–C/C=C fraction increases to 51.61%, whereas the imide-carbonyl contribution decreases to 4.64%. The latter is approximately 43% lower than the untreated value. Combined with the strong reduction in total oxygen concentration, the C 1s results indicate substantial degradation of imide-associated structures and decarbonylation, accompanied by reconstruction toward a carbon-enriched aromatic/conjugated near-surface environment. This interpretation is consistent with the general irradiation principle that increasing energetic-particle exposure can drive polymer-chain scission, sputtering, and carbon-rich reconstruction (), while plasma studies on PI similarly show loss of favorable functional states when treatment becomes excessive ().
The C/N-co-implanted sample behaves differently. Its C–C/C=C and C–N/C–O contributions are close to those of untreated PI, while the fitted imide-carbonyl contribution is 8.45%. The C/N treatment therefore generates defects and chemical reconstruction without producing the severe carbonyl depletion observed for N implantation alone.
3.3.3 O 1s spectra
The O 1s spectra were resolved into C=O-related oxygen, dominated by imide carbonyl oxygen, and a higher-binding-energy C–O-related contribution associated primarily with ether/single-bonded or reconstructed oxygen environments. The O 1s high-resolution component distributions are shown in Table 6.
TABLE 6
| Sample | C=O-related O (%) | C–O-related O (%) |
|---|---|---|
| Untreated PI | 77.43 | 22.57 |
| 6#C | 83.86 | 16.14 |
| 19#N | 27.39 | 72.61 |
| 11#C/N | 85.28 | 14.72 |
O 1s high-resolution component distributions. Area fractions are relative within the O 1s envelope.
The untreated PI, surface is dominated by C=O-related oxygen. C implantation produces only a moderate redistribution of the two oxygen environments while maintaining nearly unchanged total oxygen content.
The N-treated sample shows the most dramatic change: the relative C=O contribution decreases to 27.39%, whereas the C–O-related fraction increases to 72.61%. Importantly, this increase in the relative C–O fraction must not be interpreted as an absolute increase in C–O functionality. The total oxygen concentration of the N-treated surface is only 1.59 at%. Therefore, the O 1s result instead indicates that most of the original carbonyl oxygen has been removed and that the small residual oxygen population is redistributed toward higher-binding-energy single-bonded or reconstructed environments.
This trend is consistent with both the substantial decrease in the C 1s imide-carbonyl fraction and the strong carbon enrichment observed in the survey spectrum.
In contrast, the C/N-treated surface retains 5.52 at% total oxygen and an O 1s C=O fraction of 85.28%. C/N co-implantation therefore avoids the extensive carbonyl depletion characteristic of N-only implantation and retains or reconstructs a comparatively carbonyl-rich surface chemical environment. This distinction is relevant because oxygen-containing functionalities can substantially enhance metal adsorption and PI/Cu bonding; , for example, attributed the plasma-induced increase in Cu/PI adhesion to improved adsorption associated with introduced oxygen functional groups, although their chemistry and treatment mechanism differ from the present ion-implantation system.
3.3.4 N 1s spectra
The N 1s spectra further distinguish the N-treated surface from the other conditions. The principal experimental N 1s peak positions are approximately 399.82 eV for untreated PI, 399.72 eV for C-treated PI, 399.28 eV for N-treated PI, and 399.92 eV for C/N-treated PI.
The N-treated sample therefore exhibits an overall shift of approximately 0.54 eV toward lower binding energy relative to untreated PI. In addition, its higher-binding-energy fitted envelope is substantially broader than those of the other samples.
The N 1s envelope of irradiated PI contains overlapping contributions from imide nitrogen and reconstructed non-equivalent nitrogen environments. For this reason, particularly for the N-treated surface, the fitted component areas should be considered semi-quantitative and should not be interpreted directly as the concentration of intact imide nitrogen.
The combined peak shift, broadening, reduction in total N concentration, and accompanying C/O redistribution indicate substantial reconstruction of nitrogen-containing bonding environments after N implantation. By contrast, the N 1s response of C/N-treated PI remains much closer to untreated PI, again demonstrating that dual-ion implantation generates a distinct chemical state rather than reproducing the strong N-only reconstruction.
For a consistent semi-quantitative comparison, the two-envelope N 1s fitting parameters are summarized in Table 7.
TABLE 7
| Sample | Low-BE center (eV) | Low-BE area (%) | High-BE center (eV) | High-BE area (%) | High-BE FWHM (eV) |
|---|---|---|---|---|---|
| Untreated PI | 398.720 | 45.07 | 400.373 | 54.93 | 1.706 |
| 6#C | 398.813 | 51.78 | 400.458 | 48.22 | 1.660 |
| 19#N | 398.566 | 29.01 | 400.033 | 70.99 | 2.582 |
| 11#C/N | 398.796 | 48.03 | 400.456 | 51.97 | 1.672 |
N 1s two-envelope fitting parameters used for semi-quantitative inter-sample comparison.
The markedly broadened high-BE, envelope of 19#N should not be interpreted directly as intact imide-N, content; the N 1s deconvolution is used primarily for comparative trend analysis.
3.3.5 Implications of XPS for Cu/PI adhesion
The XPS results provide direct evidence of implantation-induced changes in the pre-deposition PI surface and are therefore useful for interpreting, but not directly establishing, the origin of the adhesion differences. The N-treated surface undergoes the largest overall chemical transformation, yet its Cu/PI peel strength is only 0.20 N mm-1. The strongest chemical modification therefore does not correspond to the strongest interface.
Excessive decarbonylation, heteroatom depletion, and carbon enrichment may generate numerous defect sites while simultaneously reducing the chemical diversity and/or structural integrity of the modified polymer layer. Such extensive reconstruction may reduce the integrity of the near-surface layer, which provides one plausible explanation for why the strongly modified N-treated surface does not exhibit the highest peel strength.
The C-treated surface undergoes much less chemical reconstruction, but the corresponding adhesion is even lower at 0.14 N mm-1.
The C/N-treated surface occupies a different regime. It combines irradiation-induced modification with retention or reconstruction of substantial O- and N-containing environments and avoids the extreme deoxygenation associated with N treatment. Such a surface may provide a more favorable precursor state for subsequent Cu adsorption, nucleation, and interfacial interaction while retaining adequate polymer-network integrity; however, these interfacial processes are inferred rather than directly observed in the present study.
The present XPS, ATR-FTIR, Raman, and AFM measurements were performed on the PI surfaces before Cu deposition. They therefore establish implantation-induced changes in surface chemistry, molecular structure, and topography, but do not directly resolve the buried Cu/PI interface or identify specific interfacial bonds. Accordingly, possible Cu–O, Cu–N, or related interfacial interactions are discussed only as plausible mechanistic interpretations. Direct verification would require dedicated buried-interface characterization, such as depth-resolved XPS, cross-sectional TEM/EELS, or other interface-sensitive spectroscopic measurements.
3.4 ATR-FTIR: molecular-bond evolution and its relationship to adhesion
The ATR-FTIR spectra (Figure 5) retain the principal molecular fingerprint of aromatic PI for all four samples. The characteristic imide C=O bands near 1774 and 1710–1711 cm-1, the imide C–N-related band near 1,370 cm-1, the aromatic-ring vibration near 1,496 cm-1, and the ether/backbone bands near 1,237–1,085 cm-1 remain identifiable after implantation. No new dominant absorption band appears, indicating that the treatments mainly modify the near-surface bonding environment rather than generate a new bulk polymer phase.
FIGURE 5
The extent of molecular-bond modification differs markedly among the treatments and is consistent with the XPS results. C implantation produces the smallest overall change, with the imide, aromatic, and ether-related features remaining comparatively well preserved. N implantation causes the strongest attenuation of these bands and, together with the XPS evidence of carbon enrichment, oxygen depletion, and reduced imide-carbonyl states, indicates substantial imide-ring damage, decarbonylation, and carbon-rich reconstruction. C/N co-implantation produces an intermediate but distinct response, with significant modification but substantially less degradation and oxygen depletion than N-only implantation.
The most strongly modified N-treated surface exhibits only 0.20 N mm-1 peel strength, whereas the less severely degraded C/N-treated surface reaches 1.63 N mm-1. This contrast indicates that extensive molecular damage alone does not promote strong Cu/PI adhesion.
3.5 Raman: aromatic-framework reorganization and its relationship to adhesion
Raman interpretation requires care because pristine PI itself exhibits strong molecular vibrations in the 1,300–1,650 cm-1 range, overlapping the conventional D- and G-band region of disordered carbon. The untreated PI spectrum already shows maxima near 1,370.94 and 1,592.05 cm-1; therefore, direct D/G assignment or I_D/I_G analysis would risk overestimating carbonization. For this reason, the spectra are compared using two empirical composite envelopes in the approximately 1,300–1,450 and 1,520–1,660 cm-1 ranges rather than treating them as independent graphite-like D and G bands.
I_D/I_G and A_D/A_G are therefore not used as quantitative measures of defect density, graphitization, or carbonization. The composite-envelope fitting parameters used for inter-sample comparison are summarized in Table 8.
TABLE 8
| Sample | Low-envelope center (cm-1) | Low FWHM (cm-1) | High-envelope center (cm-1) | High FWHM (cm-1) |
|---|---|---|---|---|
| Untreated PI | 1,370.39 | 66.53 | 1,593.03 | 74.27 |
| 6#C | 1,379.84 | 47.58 | 1,599.71 | 47.60 |
| 19#N | 1,364.97 | 67.64 | 1,587.85 | 71.04 |
| 11#C/N | 1,365.37 | 63.57 | 1,586.84 | 66.73 |
Composite Raman-envelope fitting parameters used for comparative analysis.
C implantation produces the strongest Raman-active reorganization: both composite envelopes shift to higher wavenumber and narrow substantially relative to untreated PI. However, the XPS and ATR-FTIR results show that the overall elemental composition and PI molecular fingerprint remain comparatively well preserved, so this narrowing is interpreted as local aromatic/conjugated-network rearrangement rather than evidence of the highest degree of graphitization.
N implantation produces broader, lower-wavenumber composite envelopes. When considered together with the pronounced XPS deoxygenation/carbon enrichment and the strong ATR-FTIR attenuation, this response is consistent with a chemically heterogeneous carbon-rich near-surface region. C/N-treated PI shows Raman-envelope positions closer to the N-treated sample, but its XPS and ATR-FTIR signatures are distinctly different, confirming that similar Raman positions do not imply identical surface chemistry.
Most importantly, the Raman trend does not follow the adhesion trend. C treatment shows the strongest Raman spectral narrowing but the lowest peel strength, whereas C/N treatment gives the highest peel strength without the strongest narrowing. Together with the XPS and ATR-FTIR results, this comparison indicates that aromatic-framework reorganization or carbon-rich reconstruction alone cannot account for the observed Cu/PI adhesion trend. (Figure 6).
FIGURE 6
3.6 Cu-film adhesion and electrical performance: integrated structure–property correlation
The metallization results are summarized in Table 9 for peel strength and Table 10 for sheet resistance. To establish the structure–property relationship directly, these performance data are compared below with the surface-energy, AFM, XPS, ATR-FTIR, and Raman results rather than interpreted as isolated measurements.
TABLE 9
| Sample | Specimen 1 | Specimen 2 | Specimen 3 | Specimen 4 | Specimen 5 | Mean | SD | Result (N/mm) | RSD (%) |
|---|---|---|---|---|---|---|---|---|---|
| Untreated PI | 0.071 | 0.053 | 0.063 | 0.061 | 0.062 | 0.06 | 0.01 | 0.06 ± 0.01 | 10.30 |
| 6#C | 0.134 | 0.126 | 0.151 | 0.141 | 0.162 | 0.14 | 0.01 | 0.14 ± 0.01 | 9.90 |
| 19#N | 0.211 | 0.198 | 0.187 | 0.209 | 0.196 | 0.20 | 0.01 | 0.20 ± 0.01 | 4.90 |
| 11#C/N | 1.657 | 1.621 | 1.602 | 1.645 | 1.617 | 1.63 | 0.02 | 1.63 ± 0.02 | 1.40 |
Peel-strength results for untreated and ion-modified PI (mean ± SD, n = 5).
TABLE 10
| Sample | Point 1 | Point 2 | Point 3 | Point 4 | Point 5 | Mean (mΩ/□) | SD (mΩ/□) | Result (mΩ/□) | RSD (%) |
|---|---|---|---|---|---|---|---|---|---|
| Untreated PI | 15 | 14 | 16 | 15 | 15 | 15.00 | 0.71 | 15.00 ± 0.71 | 4.70 |
| 6#C | 21 | 20 | 20 | 20 | 19 | 20.00 | 0.71 | 20.00 ± 0.71 | 3.50 |
| 19#N | 14 | 14 | 15 | 14 | 14 | 14.20 | 0.45 | 14.20 ± 0.45 | 3.10 |
| 11#C/N | 17 | 17 | 18 | 17 | 16 | 17.00 | 0.71 | 17.00 ± 0.71 | 4.20 |
Surface sheet resistance of untreated and ion-implanted samples measured by the four-point-probe method (mean ± SD, n = 5).
C/N co-implantation produces the highest interfacial adhesion, with a peel strength of 1.63 N mm-1, approximately one order of magnitude greater than either single-ion treatment. This enhancement cannot be explained by surface free energy or roughness alone: the three implanted surfaces have closely matched polar surface-energy components, and C-treated PI, already exhibits substantial roughness (S_q = 4.60 nm) but only 0.14 N mm-1,peel strength.
The contrasting peel-strength results cannot be explained by any single surface descriptor. C-treated PI already exhibits substantial nanoscale roughness, but its surface chemistry and molecular structure are comparatively less reconstructed, and it shows only a modest increase in adhesion. In contrast, N treatment produces the strongest XPS compositional reconstruction and the most pronounced ATR-FTIR attenuation, indicating substantial chemical and molecular modification, yet the resulting peel strength remains moderate. C treatment also produces the strongest Raman-active aromatic-framework reorganization, but this does not correspond to the highest adhesion. C/N co-implantation instead combines the highest nanoscale roughness with retained/reconstructed O- and N-containing chemical environments and comparatively less severe molecular degradation. These correlated observations indicate that the high-adhesion state is associated with a balanced reconstructed surface in which nanoscale topographical activation, chemical functionality, irradiation-induced defects, and preservation of sufficient polymer-network integrity coexist, rather than with the maximum change in any individual descriptor.
The sheet-resistance trend is different: the N-treated sample exhibits the lowest value (14 mΩ/□), compared with 17 mΩ/□ for C/N and 20 mΩ/□ for C treatment. This contrast shows that the reconstructed surface state associated with maximum Cu/PI adhesion is not identical to that associated with minimum Cu-film resistance. Mechanical interfacial performance and electrical film performance are therefore linked to different aspects of the implantation-induced surface state.
The sheet-resistance trend differs from the adhesion trend. The N-treated sample exhibits the lowest sheet resistance, whereas the C/N-treated sample shows the highest peel strength. This divergence suggests that interfacial adhesion and Cu-film electrical continuity are associated with different aspects of the reconstructed PI surface. Adhesion correlates with the combined effects of nanoscale topography, retained/reconstructed heteroatom-containing environments, irradiation-induced defects, and preservation of polymer-network integrity. By contrast, sheet resistance may also depend on subsequent Cu nucleation, island coalescence, grain connectivity, porosity, and film continuity. This interpretation is qualitatively consistent with previous metallization studies reporting denser or more electrically continuous Cu films after plasma-enabled PI surface modification (; ), while laser-activated Cu patterns on PI have also retained good electrical conductance under cyclic bending (). Because these post-deposition processes and the buried Cu/PI interface were not directly characterized here, their contribution should be regarded as a plausible interpretation rather than a verified mechanism.
3.7 Integrated structure–property relationship and implantation-induced mechanism
The combined surface-energy, AFM, XPS, ATR-FTIR, Raman, adhesion, and electrical results support an implantation-induced structure–property framework summarized schematically in Figure 7. The experimentally observed pre-deposition surface states are correlated here with the subsequent Cu/PI adhesion and Cu-film electrical responses. Because neither the buried Cu/PI interface nor the post-deposition Cu microstructure was directly resolved, the framework should be regarded as a correlation-based mechanistic interpretation rather than direct structural evidence.
FIGURE 7
The different trends in peel strength and sheet resistance indicate two partially distinct performance-related responses. Cu/PI adhesion is associated with the combined effects of nanoscale topography, irradiation-induced defects, reconstructed surface chemistry, and preservation of sufficient polymer-network integrity, whereas Cu-film sheet resistance may additionally depend on subsequent metal-growth processes. The surface state associated with maximum adhesion is therefore not necessarily the same as that associated with minimum electrical resistance.
Energetic-ion impact deposits energy into the near-surface region of PI and can induce bond cleavage, atomic recoil, radical formation, selective sputtering, rebonding, crosslinking, local conjugation, and nanoscale topographical evolution. The balance among these processes depends on both physical energy deposition and ion chemistry. Dose-dependent N+ implantation of PTFE illustrates how increasing irradiation severity can shift the response from structural modification to sputter-dominated roughening and eventually to C=C-rich carbonization ().
Related plasma studies provide additional mechanistic context, but not direct evidence of an identical buried interface in the present system. Activated polymer chains and radical reactions can participate in the formation of a metal-containing transition region, as reported for a C/Cu mixed interlayer on PET (), while excessive plasma modification of PI can reduce peel strength after an optimum treatment condition is exceeded ().
C implantation primarily produces nanoscale roughening and aromatic-framework rearrangement while causing comparatively limited elemental and molecular redistribution. Its low peel strength despite substantial roughness shows that topographical activation and aromatic reconstruction alone are insufficient to explain strong Cu/PI adhesion.
N implantation produces the strongest chemical reconstruction, including carbon enrichment, oxygen depletion, reduced imide-carbonyl contribution, and marked attenuation of the PI molecular fingerprint. This strongly reconstructed state is associated with the lowest Cu-film sheet resistance but only moderate adhesion, suggesting that extensive chemical modification may favor aspects of Cu-film formation without maximizing interfacial mechanical strength. The detailed post-deposition growth processes remain unverified in the present study.
C/N co-implantation produces a distinct reconstructed state rather than a simple superposition of the two single-ion cases. It combines the highest nanoscale roughness with retained/reconstructed heteroatom-containing chemical environments and comparatively preserved polymer-network integrity.
In the present system, this combination is correlated with the highest measured peel strength and can therefore be described as a balanced or cooperative reconstruction state. However, because the buried interface was not directly characterized, the relative contributions of chemical interaction, mechanical interlocking, and other interfacial processes cannot be separated or verified directly.
Ion species and implantation conditions → near-surface energy deposition and bond scission → implantation-induced chemical/structural reconstruction → reconstructed surface precursor state → Cu/PI adhesion and Cu-film electrical continuity.
The key implication is that maximum Cu/PI adhesion is associated with the combined quality and balance of the reconstructed surface state rather than with the maximum change in any single descriptor. The different sheet-resistance trend further indicates that minimum Cu-film resistance follows a different surface-state requirement. Adhesion and electrical performance should therefore be considered partially decoupled optimization targets, while direct interface- and film-sensitive characterization will be required to establish the underlying atomic-scale mechanisms.
4 Conclusion
C-ion implantation, N-ion implantation, and C/N dual-ion co-implantation were used to modify PI under deliberately matched surface-free-energy conditions. Although the three modified surfaces exhibited similar total surface free energies of 46.43–47.22 mJ m-2 and closely clustered polar components of 7.09–7.64 mJ m-2, their Cu/PI peel strengths differed by more than an order of magnitude. The C/N-treated sample reached 1.63 N mm-1, compared with 0.14 N mm-1 for C treatment and 0.20 N mm-1 for N treatment, showing that surface free energy alone does not account for Cu/PI adhesion.
SEM showed no severe microscale damage, whereas AFM revealed treatment-dependent nanoscale roughening. The C/N-treated surface exhibited the highest S_q (5.34 nm), but the C-treated surface also showed substantial roughness (4.60 nm) while retaining weak adhesion. Nanoscale roughness is therefore a contributing, but not sufficient, descriptor of the adhesion response.
Spectroscopic analyses further exclude a single-parameter explanation. XPS showed relatively limited elemental redistribution after C implantation, pronounced carbon enrichment and oxygen depletion after N implantation, and a comparatively preserved heteroatom-containing surface after C/N treatment. ATR-FTIR identified the strongest molecular degradation after N implantation, while Raman analysis showed the strongest aromatic-framework reorganization after C implantation. None of these individual trends follows the peel-strength ranking.
The highest Cu/PI adhesion is instead associated with the C/N-treated surface, where pronounced nanoscale activation coexists with retained/reconstructed O- and N-containing chemical environments and comparatively preserved polymer-network integrity. These pre-deposition characteristics are consistent with a balanced or cooperative reconstructed state, but they do not directly establish the detailed bonding configuration at the buried Cu/PI interface.
Finally, the divergence between the adhesion and sheet-resistance trends indicates that polymer/metal interfacial strength and Cu-film electrical performance are partially decoupled optimization targets. More broadly, the present results suggest that these properties may be tailored through deliberate control of the implantation-induced reconstructed near-surface state rather than by maximizing a single descriptor such as surface free energy, roughness, or the extent of chemical modification. Future work should therefore combine systematic optimization of implantation parameters with direct characterization of the buried Cu/PI interface and post-deposition Cu-film microstructure. Such studies will help establish more quantitative relationships among implantation-induced surface reconstruction, interfacial bonding, metal nucleation and growth, adhesion, and electrical transport.
Statements
Data availability statement
The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.
Author contributions
MC: Conceptualization, Formal Analysis, Investigation, Methodology, Validation, Writing – original draft. YZ: Formal Analysis, Validation, Writing – review and editing. XL: Validation, Writing – review and editing. KY: Validation, Writing – review and editing. XG: Formal Analysis, Writing – review and editing. JO: Formal Analysis, Writing – review and editing. DT: Project administration, Writing – review and editing. FJ: Funding acquisition, Writing – review and editing. JZ: Investigation, Writing – review and editing.
Funding
The author(s) declared that financial support was received for this work and/or its publication. This research was funded by the SWIP Innovation Action Program, grant number 202301XWCX003.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
BiswasR. K.FaridN.O’ConnorG.ScullyP. (2020). Improved conductivity of carbonized polyimide by CO2 laser graphitization. J. Mater. Chem. C8, 4493–4501. 10.1039/C9TC05737D
2
ElbakoushF. E.KhanQ. U.UllahM.UllahA.KhanA. U.KhanJ.et al (2021). Characterization and thermal degradation study of carbonization the polyimide (PMDA/ODA)/Fe composite films. Trans. Electr. Electron. Mater.22, 843–850. 10.1007/s42341-021-00309-0
3
IPC (2023). IPC-TM-650 CN 2023 Test Methods Manual: Peel Strength of Flexible Printed Wiring Materials. IPC: Bannockburn, IL, 125–130.
4
KuboY.TanakaH.SaitoY.MizoguchiA. (2018). Fabrication of a bilayer structure of Cu and polyimide to realize circuit microminiaturization and high interfacial adhesion in flexible electronic devices. ACS Appl. Mater. Interfaces10, 44589–44602. 10.1021/acsami.8b15835
5
LiH.WangX.WuT.GongY.ZhaoH.LiuZ.et al (2023). Mechanical enhancement and dielectric properties of SiO2-contained polyimides under high frequency. J. Mater. Sci. Mater. Electron.34, 2310. 10.1007/s10854-023-11731-w
6
LiY.WangY.WangY.WuY. (2023). Achieving good bonding strength of the Cu layer on PET films by pretreatment of a mixed plasma of carbon and copper. ACS Appl. Mater. Interfaces15, 12590–12602. 10.1021/acsami.2c23144
7
ManB. Y.ZhangY. H.LüG. H.LiuA. H.ZhangQ. G.GuzmanL.et al (2005). Study on surface modification of polytetrafluoroethylene by N+ ion implantation. Acta Phys. Sin.54, 837–841.
8
OwensD. K.WendtR. C. (1969). Estimation of the surface free energy of polymers. J. Appl. Polym. Sci.13, 1741–1747. 10.1002/app.1969.070130815
9
TanW.-Y.JianL.-F.ChenW.-P.ZhangY.-W.LuX.-C.HuangW.-J.et al (2023). A facile strategy for intrinsic low-Dk and low-Df polyimides enabled by spirobifluorene groups. Chin. J. Polym. Sci.41, 288–296. 10.1007/s10118-022-2824-z
10
TheilerG.GradtT. (2015). Tribological characteristics of polyimide composites in hydrogen environment. Tribol. Int.92, 162–171. 10.1016/j.triboint.2015.06.001
11
WanC.ZhanS.JiaD.YangT.ChenH.YaoC.et al (2022). Tribological behavior of nanographite/polyimide composite under drying sliding condition. Wear494-495, 494–495. 10.1016/j.wear.2022.204271
12
WangE.SongY.ShangL.ZhangG.WangS. (2022). Plasma surface pretreatment to improve interfacial adhesion strengths of sputtered Cu on polyimide film. Surf. Topogr. Metrol. Prop.10, 045005. 10.1088/2051-672X/ac97f9
13
XiangJ.ZhouG.HongY.HeW.WangS.ChenY.et al (2022). Direct additive copper plating on polyimide surface with silver ammonia via plasma modification. Appl. Surf. Sci.587, 152848. 10.1016/j.apsusc.2022.152848
14
YooY.-H.RheeJ.-M.LeeM.-H.YuS.-C. (2003). Two-dimensional raman correlation spectroscopy study of the pathway for the thermal imidization of poly(amic acid). Bull. Korean Chem. Soc.24, 357–362. 10.5012/BKCS.2003.24.3.357
15
YouJ.-L.ChangC.-P.PuN.-W.ChenY.-S.WangL.-H.PanK.-H.et al (2022). Electroless plating of a 5G copper antenna on polyimide patterned with laser-induced selective activation and curing of metal–organic catalyst. Appl. Surf. Sci.599, 153990. 10.1016/j.apsusc.2022.153990
16
ZhangD.ZouD.GuoR.HuangY.ChangX.WuZ.et al (2026). A pulse-modulated microwave atmospheric pressure plasma jet and its applications in polymer modifications. Plasma Chem. Plasma process.46, 54. 10.1007/s11090-026-10664-6
Summary
Keywords
copper metallization, interfacial adhesion, ion implantation, polyimide, surface reconstruction
Citation
Chen M, Zhang Y, Liu X, Yao K, Geng X, Ou J, Tang D, Jin F and Zhou J (2026) Ion-implantation-induced polyimide reconstruction and Cu interfacial adhesion. Front. Mater. 13:1972906. doi: 10.3389/fmats.2026.1972906
Received
19 August 2026
Revised
01 October 2026
Accepted
06 October 2026
Published
29 October 2026
Volume
13 - 2026
Edited by
Pratheep K Annamalai, University of Southern Queensland, Australia
Reviewed by
Xuelian Wu, Anhui University of Technology, China
Zhen Zhang, East China University of Science and Technology, China
Tian Li, Lanzhou University of Technology, China
Updates
Copyright
© 2026 Chen, Zhang, Liu, Yao, Geng, Ou, Tang, Jin and Zhou.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Meiyan Chen, mychen0014@126.comchenmeiyan@swip.ac.cn
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.