ORIGINAL RESEARCH article

Front. Med. Technol., 04 November 2026

Sec. Medtech Data Analytics

Volume 8 - 2026 | https://doi.org/10.3389/fmedt.2026.1914040

From landmark uncertainty to clinical confidence: screening for developmental dysplasia of the hip

  • 1. Department of Computer Science, University of Oxford, Oxford, United Kingdom

  • 2. The Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), Kadoorie Institute of Trauma and Emergency Care, University of Oxford, Oxford, United Kingdom

  • 3. Liverpool Institute of Child Health and Well Being, University of Liverpool, Liverpool, United Kingdom

  • 4. Alder Hey Children’s Hospital, Liverpool, United Kingdom

Abstract

Clinical image annotation-based assessment methods often rely on anatomical landmarks to derive landmark-based measurements (angle or distance) that underpin screening, diagnosis, and treatment decisions. In screening pathways, landmark-based measurements typically use predefined thresholds to classify patients as healthy or unhealthy. Natural variability exists among clinicians in landmark placement and, consequently, in the derived measurement and screening decisions, reflecting genuine uncertainty in these assessments. We propose a method to estimate uncertainty associated with landmark-based measurements. By defining this measurement uncertainty, we derive a confidence estimate for the clinical screening task to provide context for the measured uncertainty. While the approach is applicable to screening in general, we demonstrate its utility in detecting developmental dysplasia of the hip in neonates using two standard clinical landmark-based measurements: the Graf angle and the femoral head coverage percentage. We show a strong correlation between multiple clinicians’ confidence and model’s confidence. This indicates that the model and the clinicians identify the same cases that are difficult or borderline. To our knowledge, this work presents the first method to evaluate a model’s confidence when predicting clinically relevant landmark-based measurements. This confidence estimate can establish trust in automated models, facilitating wider clinical adoption, which, in turn, can widen access to screening.

1 Introduction

Many clinical decisions are informed by medical images that are quantified using annotation-based measurements. Clinicians place anatomical landmarks on images and derive measurements (such as angles or distances) to guide subsequent diagnostic and treatment decisions. Automated methods can streamline this process, with various studies demonstrating that such methods perform well in predicting landmark-based measurements [1–4]. However, there are roadblocks that prevent widespread clinical deployment of automated tools [5].

Current models are often limited by the scarcity and quality of training data, which includes annotations performed by clinicians (as highlighted in recent work on data-efficient landmark detection) [6, 7]. In most medical imaging tasks, clinical annotations are highly subjective and exhibit significant inter- and intra-rater variability. This variability introduces implicit uncertainty into the training labels. Therefore, when models trained on this data report only a single prediction, they fail to represent the underlying clinical uncertainty present in real-world decision-making.

This problem is particularly important in healthcare screening. Screening takes a defined population, performs a “test,” and applies thresholds to the result to differentiate unhealthy from healthy, or at-risk from not-at-risk. Many screening protocols rely on normative reference ranges derived from healthy populations, commonly defined as the central 95% reference interval, or on fixed diagnostic thresholds. In this context, uncertainty is particularly important: as an example, small changes in landmark placement can shift a measurement across a decision boundary, leading to a different outcome. Model outputs that do not quantify uncertainty therefore provide limited support for clinicians, especially in borderline or difficult cases where clinicians may disagree with one another.

We seek to encode the uncertainty explicitly in landmark-based measurements and to derive a confidence estimate that is directly interpretable within a clinical screening workflow. In this work, “uncertainty” refers to a probability distribution over possible measurement values, while “confidence” is a quantitative summary derived from that distribution with respect to clinically meaningful decision thresholds (Figure 1, Section 2.3). The resulting confidence estimate identifies cases that lie close to the screening boundary and may therefore require expert review, while potentially allowing some automated screening decisions to be made with greater assurance when confidence is high.

Figure 1

To our knowledge, no work has investigated the uncertainty or confidence of the output of automated methods for landmark-based measurements for screening, which presents a significant gap in clinically relevant research.

1.1 Clinical background

Developmental dysplasia of the hip (DDH) is a childhood condition in which the femoral head is not correctly aligned within the hip socket. If detected early, treatment is usually simple (non-surgical) with a removable harness that the child wears for weeks; if missed, the child may require reconstructive surgery. For this reason, some countries employ ultrasound (US)-based screening in early infancy to quantitatively and qualitatively assess alignment of the hip. Universal ultrasound screening for DDH is currently performed in some parts of Europe, such as Austria [8]; however, it remains costly due to the need for expert medical personnel specifically trained in this procedure.

DDH screening is well-suited to automation because it follows a structured, landmark-based workflow. Clinicians place a number of anatomical landmarks on an US image and compute measurements from these points. These measurements are then compared with predefined thresholds to make a binary screening decision (healthy vs. unhealthy). However, there is some debate concerning how best to determine the category severity of the abnormality [9, 10] from US images, although two annotation-based assessment methods dominate clinical practice.

1.2 Femoral head coverage assessment method

One method of categorising DDH severity is the femoral head coverage (FHC) method. In this method, a line is drawn parallel to the upper edge of the ilium, and the landmark-based measurement of FHC is calculated as the proportion of the femoral head lying below this line, as illustrated in Figure 2 [11, 12]. A scan is then categorised based on this FHC value as healthy (>50%) or unhealthy (50%) [13]. Treatment decisions are then made on the basis of this categorisation, so we refer to the FHC value of as being on the “decision boundary.”

Figure 2

1.3 Graf assessment method

The other main method of categorising DDH severity is Dr. Graf’s method [14]. In this method, the bony coverage is calculated using two lines—the “base line” parallel to the upper edge of the ilium and the “bony roof line” from the bony “drop” (lower limb of ilium) towards the lateral edge of the ilium. The angle between these lines gives the landmark-based measurement called the Graf angle (), as illustrated in Figure 2. Based on the value of this , a scan is assigned a Graf class of healthy () or unhealthy (). This binary thresholding makes the problem particularly sensitive to small numerical errors near the decision boundary.

1.4 Clinical annotation variability

Image interpretation in clinical practice is inherently subjective, resulting in both intra- and inter-rater variability in derived measurements. Such variability can influence clinical decisions and ultimately affect patient outcomes.

In DDH, previous studies have reported substantial intra- and inter-rater variability for both the Graf angle and FHC measurements when derived from manual image annotations [15, 16]. More recent work has investigated variability in landmark-based Graf measurements across clinicians [17, 18]. However, to our knowledge, clinician variability for landmark-derived FHC measurements has not been systematically quantified.

Understanding clinician variability is essential when developing automated measurement systems, as it provides a clinically meaningful benchmark against which model performance can be evaluated.

1.5 Automated landmark-based measurements

Automated methods provide a pathway towards early detection of DDH, potentially reducing the clinical expertise needed in remote places or reducing the time needed for clinicians to review scans. For automated methods to be easy for clinicians or other healthcare professionals to use, we are motivated to make the automated pipeline similar to existing clinical workflows.

In the case of screening for DDH, we divide the clinical workflow into: landmark placement, calculation of landmark-based measurements ( or FHC), and then final classification (screening decision). This facilitates understanding and fosters trust by providing not only insight into the decision-making process but also a quantitative analysis of each step in the clinical workflow, ensuring that the workflow is properly represented.

Previous work automating the screening process for DDH has tried to replicate the clinical workflow by predicting landmarks and/or segmentation of critical structures as an intermediate to estimate landmark-based measurements [19–26]. More recent studies have used high-resolution pose estimation [HRNet; [27]] for predicting landmark-based measurements (), showing better performance compared to other networks [23, 26, 28]. This is because HRNet provides a strong balance between accuracy and computational efficiency while ensuring rich, high-resolution feature representations. Although these studies report their models as the “best-performing,” to our knowledge, no work has evaluated each step in the entire DDH clinical workflow, making it difficult to confirm these claims.

1.6 Automated pipeline evaluation

Given that our automated pipeline mirrors the DDH clinical workflow, performance must be evaluated at each stage, including landmark localisation, derived measurements (angles and percentages), and final classification. This enables a holistic assessment of model performance.

Recent work has evaluated all three stages [25]. However, these studies did not provide a unified evaluation of the complete screening workflow, nor did they assess how measurement variability propagates through clinically relevant measurements and ultimately affects screening decisions. In the present work, we combine these strands by evaluating landmark localisation, landmark-based measurements, classification, uncertainty, and confidence within a single framework. We further extend our agreement metric [17], which quantifies the effect of measurement variations on the final classification, by applying it to additional clinical workflows and validating the resulting confidence estimates against multiple clinicians.

Previous studies have primarily reported classification accuracy [19, 21, 29]. However, in a screening setting, recall (sensitivity) is particularly important because missed cases may lead to delayed treatment and poorer outcomes. Precision is important to counter-balance recall, as it reflects the number of patient hip ultrasound scans requiring further review. From a clinical perspective, identifying as many affected patient hips as possible is generally prioritised, as early detection enables timely intervention and may reduce the need for more complex and costly treatment later if patients requiring treatment are missed. Consequently, a comprehensive evaluation should consider the full range of classification metrics rather than accuracy alone.

1.7 Model uncertainty and confidence

To promote the adoption of automated methods in a clinical setting, it is helpful for automated methods to report an estimate of confidence or uncertainty in the output predictions. These estimates help the model to identify difficult cases and can indicate when clinicians need to intervene. In this work, we provide an uncertainty estimate for the landmark localisation stage of the pipeline as well as relevant landmark-based measurements. We further use the uncertainty to develop a tangible estimate of confidence, which can be used to help identify when a model considers a case to be more difficult.

1.8 Landmark localisation uncertainty and confidence

For automated landmark detection, “heatmaps” are increasingly used to represent model predictions [25, 30, 31]. These “heatmaps” allow the localisation uncertainty in landmark placement to be quantified and visualised. In a similar way, we can represent the variance between clinician annotations (inter-rater variability) using localisation uncertainty by taking the average of the localisation uncertainty of multiple clinicians for one specific annotation [32]. This localisation uncertainty can then be used to quantify a level of confidence in landmark placement. For example, we could use a metric like the expected radial error to quantify the spatial variance of the probability distribution (uncertainty), giving an intuitive measure of how uncertain the model is about the landmark’s exact location [30].

When modelling multi-annotator uncertainty, it becomes increasingly important to consider how landmark uncertainty propagates to downstream measurements. Rather than treating a single manual annotation as absolute ground truth, recent work has advocated evaluating automated landmark localisation relative to the distribution of expert annotations, thereby accounting for inherent annotation uncertainty [33].

1.9 Landmark-based measurements uncertainty and confidence

We define measurement uncertainty as the “uncertainty” of a measurement (e.g., angles and/or distances) when based on an annotation or landmark that contains localisation uncertainty. Here, “measurement confidence” is a quantitative estimate derived from an “uncertainty,” which can be used to quantify how “sure” an output is based on a defined method. In this work, confidence is defined as the probability mass lying on one side of a clinically meaningful decision boundary (see Figure 1).

Most work to date focuses on calculating relevant landmark-based measurements from the centre of predicted landmarks [3, 4, 34]. These papers report the mean and standard deviation of the predicted angles from these single points across multiple scans. To date, no work has reported a measurement uncertainty of the landmark-based measurements for each scan.

Common methods for calculating uncertainty in machine learning includes Monte Carlo dropout, Bayesian neural networks, deterministic methods, test-time augmentation, and ensemble methods [35]. None of these approaches have been used to determine uncertainty for landmark-based measurements. Challenges remain in comparing a model-derived uncertainty to a ground truth uncertainty due to a lack of available annotation data.

Our recent work uses a Monte Carlo-like approach to generate a probability distribution of the landmark-based measurements to estimate the “measurement uncertainty” of the angle predicted per patient scan [18]. This method was validated by comparing the model uncertainty to its corresponding clinical uncertainty (based on a “heatmap” from a total of 10 clinicians). The paper reports a correlation between the model confidence and the clinicians’ reported self-confidence [18]. This work did not extend to other landmark-based measurements.

By providing an automated pipeline that mirrors the clinical workflow and an associated confidence score for the predictions at each stage of the pipeline, we aim to provide insight into model decisions and allow for better clinical oversight. This insight helps improve model trust, thereby promoting clinical adoption.

1.10 Contributions

In this work, we make progress in addressing these gaps:

  • We develop a model for the prediction of landmark-based measurements for DDH, evaluating the entire clinical workflow and showing that it performs within the values reported in the literature.

  • We assess and report inter-rater variability in landmark-based measurements for DDH between one reference clinician and 10 other clinicians.

  • We propose a method for calculating uncertainty and confidence for landmark-based measurements for DDH.

  • We validate our proposed uncertainty and confidence by demonstrating a strong correlation between the model-derived and clinician-derived estimates.

2 Methods

2.1 Datasets

2.1.1 Main dataset

A total of 1,107 US scans of left and/or right hips from 885 patients were acquired from Alder Hey Children’s Hospital. Images were in DICOM format, and image arrays were extracted using Pydicom [36]. The pixel size of the dataset was reported as 0.07 0.07  (median across all scans, rounded to the nearest 10th). The image size was 1,024 768 pixels. This is referred to as the main dataset.

2.1.2 Data splits

The main dataset was split into training (70), validation (15), and test (15) sets. The main dataset classes are the healthy (60.3) vs. unhealthy (39.7) groups, as determined by clinicians during standard Graf screening at Alder Hey Children’a Hospital. The class balance (proportion of hip ultrasound scans in each class) was retained across all data splits. Keeping the class balance in the test set ensures that each class in the selected group reflects its proportion in the main dataset.

2.1.3 Data subset

From the main dataset, 70 images were randomly selected (6 of the test set). The smaller number of images in this group is attributed to the logistical challenge of gathering multiple clinicians for annotation or review purposes. The class balance in the main dataset was retained in this subset. This will be referred to as the data subset.

2.1.4 External datasets

Two datasets were collected from external hospitals to incorporate domain shift (Milton Keynes University Hospital and Royal National Orthopaedic Hospital). Each dataset contained 50 images (provided in png and jpeg formats, from MKUH and RNOH, respectively). The image size for MKUH and RNOH varied ([271–569] [278–571] pixels and [947–960] [583–587] pixels, respectively). Pixel sizes were not available.

2.1.5 Landmark annotations

Annotations were manually placed as seven key points, all at once for each scan (Figure 2). Annotations were collected from the same clinician for both the main dataset (1,107) and the external datasets (MKUH and RNOH; 50 each) using GIMP software [37]. Landmark annotations were 25 pixels in diameter and were confirmed by consulting two expert clinicians. These are the ground truth annotations.

2.1.6 Multiple clinician landmark annotations

All images in the data subset were annotated by 10 expert reviewers: five experts (consultants and attendings) and five non-experts (registrars and residents). This gave a total of 700 annotations. Annotations were 14 pixels in diameter. RAIQC was the annotation software used [38]. The landmark annotation sizes differed between the main dataset (25 pixels) and the data subset (14 pixels) because the datasets were collected as part of two independent clinical studies using different annotation software and clinician-defined default settings.

2.1.7 Combined heatmap (CombiMAP) from clinician “heatmaps”

An aggregated heatmap of all 10 clinicians was generated by taking the sum of heatmaps in each channel across all annotations. The sum of the Gaussian heatmaps, for each landmark distribution, was aggregated and then standardised for comparisons with the model (see Figure 3).

Figure 3

2.2 Automated landmark-based measurement

2.2.1 Architecture

Inputs: The network input was a US image. A Gaussian heatmap was generated for each landmark using the scikit-image package with pixel [39]. This parameter was selected empirically to introduce limited spatial uncertainty around each landmark while maintaining a localised training target.

Outputs (model “heatmaps”): The output had seven channels, one landmark per channel. This creates a per-pixel probability of the localisation uncertainty, referred to as a “heatmap” (the visual representation of the localisation uncertainty). To exclude pixels with a probability near zero in the heatmap, any value in the heatmap < 0.05 was replaced with zero and then the heatmap was renormalised to , refining the distribution.

Dataloader and augmentation: All images were padded and resized to in the data loader. Three augmentations [imgaug, [40]] were randomly selected and applied to each image during data loading at training time. The augmentation of images included speckle noise (unitless scale factor 2, controlling the standard deviation of noise relative to pixel intensity), rotation (radian-based factor 1), scaling (relative scale to original image size, factor 0.5), intensity shift (normalised intensity shift, 1.0), translation ( percentage of pixels, percentage of pixels), and a salt-and-pepper augmentation (in which up to of the image pixels were masked out in randomly chosen rectangular regions and replaced with salt-and-pepper noise).

HRNet: We implement HRNet Human Pose Estimation—a widely used variant of HRNet with a width of 32 channels. The model was loaded from GitHub with a pre-trained model on the ImageNet dataset [27]. The weights in the first two HRNet “stages” were frozen during training to reduce overfitting.

Loss function: A spatial softmax was applied to each channel to generate an output with probability-like distributions for landmark locations (“heatmaps”). The model was trained with an image loss [negative log-likelihood (NLL) with an additional L2 regularisation term], comparing the input Gaussian heatmaps with the predicted heatmaps. The output landmark is the “hottest” location in the heatmap of each channel.

Optimisation: An Adam optimiser [41] was used during training with a batch size of 8, 10 training epochs, and a learning rate of 0.005. These hyperparameters were selected based on commonly adopted settings in the literature and available computational resources.

2.2.2 Landmark-based measurements

FHC assessment method: FHC quantifies the proportion of the femoral head covered by the acetabulum (Figure 2). First, the iliac baseline is drawn parallel (using the vertical average of the two iliac points) to the upper edge of the ilium. The distance between the upper and lower femoral head landmarks defines the femoral head diameter (). In this work, is calculated as the vertical distance between the upper and lower femoral head landmarks. The portion of the femoral head located medial to the iliac baseline defines the covered distance (). This is calculated as the vertical distance between the iliac baseline and the lower femoral landmark. FHC is then calculated as follows:

Graf assessment method: The angle was calculated from landmark-derived vectors. First, the centre point of each landmark pair was determined. The iliac baseline vector was then constructed between the iliac landmark centre points. A second vector was constructed between the bony rim and bony roof landmark centre points, representing the acetabular roof. The between vectors was calculated using the inverse cosine of the normalised dot product:where and denote the iliac baseline and acetabular roof vectors, respectively (Figure 2).

2.2.3 Landmark evaluation metrics

All seven landmarks were included in the landmark metric calculations. To evaluate the performance of landmark localisation, the average mean radial error (aMRE) and the SDR were calculated.

We note that although images were cropped, padded to a fixed aspect ratio, and resized for model input, predictions were resampled back by reversing the resize and padding steps before metric computation in the original image space.

Average mean radial error: The Euclidean distance is calculated between predicted landmarks (as the centre of each landmark “heatmap”) and their equivalent annotations in the Annotation Ground Truth. The mean (“M”) across all landmarks is calculated. This value is then averaged (“a”) across all patient individual hip ultrasound images, per dataset.

Success detection rate (SDR): The SDR is calculated as the percentage of landmarks within a threshold of the aMRE (0.5, 1, 2 mm), as commonly used in the literature [25, 26, 42]. Due to the absence of pixel size in the external datasets, the SDR was calculated as the percentage of landmarks falling within defined aMRE pixel thresholds (7, 14, and 28 pixels), chosen to correspond to the literature-defined thresholds used for the main dataset.

2.2.4 Evaluation metrics for landmark-based measurements

Mean absolute differences: To compare annotation-based assessment methods, the angle and FHC percentage were calculated for each image using the corresponding landmark annotations. For the Graf assessment, the mean absolute angle difference (MAAD) was computed as the mean absolute difference between the predicted and ground-truth measurements. Similarly, for FHC, the mean absolute FHC percentage difference (MAFD) was calculated as the mean absolute difference between the predicted and the ground-truth FHC percentages:where is the ground-truth measurement (calculated from the Annotation Ground Truth), is the predicted measurement for scan , and is the total number of scans.

Agreement metrics: The percentage of the test set where MAAD fell within and of the Annotation Ground Truth is reported. The per cent “agreement” was calculated as the difference in classification assignment for these angle predictions at different thresholds, showing how often the predicted angles matched the true class label. Similarly, we report the per cent “agreement” of where MAAD fell within FHC 0.5% and FHC.

2.2.5 Model classification performance

The Graf classification and the FHC classification generated from the model predictions were evaluated separately against the Annotation Ground Truth. Accuracy, precision, and recall are reported for each classification method to enable direct comparison with existing approaches, which have typically relied on either Graf or FHC classification alone. Our more recent work has demonstrated that a combined decision strategy, in which a patient’s hip scan is classified as unhealthy if either the Graf or FHC assessment indicates an unhealthy hip (in the sense defined in Section 1), more closely reflects routine clinical practice [42]. Therefore, performance is also reported for this combined classification.

2.3 Uncertainty and confidence

2.3.1 Measurement uncertainty

A Monte Carlo-like method was used to estimate a measurement uncertainty. In each iteration (), a landmark was randomly selected from each heatmap. These landmarks were then used to calculate the landmark-based measurements ( and FHC).

The angles and FHCs for all iterations were calculated. These landmark-based measurements were binned by angle and FHC (separately) to generate histograms. The histograms were rescaled to get a total of 1 beneath the curve. This allows the histogram to represent the measurement uncertainty of the angles and the FHCs for each patient hip scan.

Uncertainty correlation: The uncertainty of the landmark-based measurements ( and ) was generated using the Monte Carlo-like mentioned above. This method was used to calculate the measurement uncertainty for both the CombiMAP and the model landmark predictions.

For each patient’s individual hip scan, the standard deviation of the model and the CombiMAP shows a weak correlation for the angle (r = 0.389; see Figure 5). The standard deviation correlation for the FHC when comparing the model and the CombiMAP was slightly higher than the angle, showing moderate correlation (r = 0.589). We also note that clustering is seen in the PCC; therefore, this is used as a reference only.

Inter-rater variability: MAAD and MAFD are reported between the reference expert and the CombiMAP. In this work, we refer to it as the “inter-rater variability.” To compare the clinician inter-rater variability to the model, MAAD and MAFD are also reported between the reference expert and model predictions.

Here, clinician inter-rater variability reflects differences in measurements produced by different clinicians compared to one reference clinician, whereas differences between clinician measurements and model predictions represent model–clinician disagreement rather than inter-rater variability or model-derived uncertainty.

2.3.2 Confidence

To calculate confidence, we define meaningful intervals within the uncertainty distribution and compute the area they enclose. This provides an estimate of how “sure” the model or clinicians are about the calculated landmark-based measurement.

The decision support confidence interval is generated from the area of the uncertainty within the decision boundaries for each landmark-based measurement (Graf decision boundary () and the FHC decision boundary (). This represents how confidently the landmark-based measurement lies on the “healthy” side of the decision boundary, meaning how confidently the patient can be discharged.

It is important to note that, since this is a binary decision for “healthy,” anything on the other side of this decision threshold would be “unhealthy.” As such, the “unhealthy confidence” becomes “one minus healthy confidence.” Hereafter, we report the confidence relative to the healthy side of the decision boundary. We have found that this has helped clinicians understand the use of this terminology in screening: a patient hip deemed “healthy” with high confidence can be discharged. This also means that, where we speak of “unhealthy,” this corresponds to a low confidence that the patient hip is “healthy,” which, in turn, corresponds to a high confidence the patient’s hip is “unhealthy.”

Confidence correlation: The confidence, based on a defined decision support threshold, was calculated for each scan for the model predictions (model confidence) and the CombiMAP’s (CombiMAP confidence). The Pearson correlation coefficient (PCC) was used to evaluate the relationship of the model confidence and the CombiMAP confidence, using both confidence thresholds defined above.

3 Results

3.1 Automated landmark-based measurement

3.1.1 Landmark metrics

The mean radial error and SDR were found to be best in the main dataset test set than in the external datasets (Table 1). The SDR was within similar ranges of 14 and 28 pixels away; however, at a threshold of 7 pixels, the Mmain dataset outperformed the external datasets. The aMRE for MKUH/RNOH could not be reported in this table due to a lack of pixel sizes.

Table 1

DatasetaMRESDR
Pixmm7 pix (%)14 pix (%)28 pix (%)
Main dataset9.070.640.0954.2284.0896.73
MKUH14.66NR46.2970.8690.29
RNOH16.52NR43.7166.5786.00
LiteratureNR0.59–1.2237.079.696.7

Landmark metrics.

The average mean radial error (aMRE) and success detection rate (SDR) are averaged over all seven landmarks. The “Literature” row gives a range of results from the literature, providing acceptable reference values [25, 26]. Some values could not be reported (NR) due to missing pixel sizes. Bolded values indicate the highest per column.

3.1.2 Metrics for landmark-based measurement

The MAAD and MAFD are reported in Tables 2, 3, respectively. The values were similar to those reported in the literature. The FHC values have not been reported in the literature to our knowledge.

Table 2

DatasetMAAD (degrees) Metrics
Main dataset4.761.4 (a:93.1)69.88 (a:94.0)
MKUH10.752.0 (a:57.7)60.0 (a:60.0)
RNOH5.840.0 (a:70.0)44.0 (a:72.7)
Literature2.2–7.06269.3

Comparison of landmark-based -angle measurement metrics.

MAAD between the ground-truth angle and the predicted angle and the values within and are reported. Within the reported and , the agreement (“a”) is reported as a normalised value. The “Literature” row summarises a range of results reported in recent work, providing acceptable reference values [25, 26, 42]. Bolded values are the best performing.

Table 3

DatasetMAFD (%)FHC metrics
1%0.5
Main dataset1.2555.4 (a:97.8)37.3 (a:96.8)
MKUH12.4622.0 (a:100.0)10.0 (a:100.0)
RNOH3.2340.0 (a:100.0)28.0 (a:100.0)
LiteratureNRNRNR

Comparison of landmark-based FHC measurement metrics.

MAFD between the Annotation Ground Truth FHC and the predicted FHC is reported. The FHCs within 0.5 and 1 are reported. The agreement (“a”) is reported as a normalised value. Bolded values are the best performing.

NR, not reported.

3.1.3 Model classification performance

The classification performance from the model-predicted landmarks is reported for the FHC method and the Graf method (see Table 4). When predicting FHC, the recall was often 100. The Graf classification results performed similarly to those in the literature.

Table 4

MethodDatasetAccuracyPrecisionRecall
FHCMain95.195.195.1
MKUH74.051.9100.0
RNOH92.085.7100.0
Literature89.9–91.693.886.5
GrafMain93.395.588.7
MKUH68.070.470.3
RNOH72.092.968.4
Literature84.4–86.085.488.2
FHC + GrafMain92.890.094.7
MKUH86.058.8100.0
RNOH74.062.578.9
Literature68.0–93.365.7–94.384.2–93.2

Model classification performance.

Accuracy, precision, and recall are reported for FHC, Graf, and the combined FHC+Graf classification. The “Literature” row summarises the range of results reported in recent work for each method and the combined methods: FHC [43], Graf [25, 26], and combined FHC+Graf [42]. Highest values in each section are reported in bold.

3.2 Uncertainty and confidence

Examples of the measurement uncertainty distributions and associated confidence estimates for both the angle and the FHC are shown in Figure 4. As per Section 2.3.2, on the left of Figure 4A, Patient 1 displays a low confidence of being on the healthy side of the (black dashed) decision threshold. It follows that there is a high confidence of this patient’s hip being on the unhealthy side of that threshold. This demonstrates how uncertainty in the predicted landmarks (shown by the landmark heatmaps being widely spread) propagates towards uncertainty in the derived angle.

Figure 4

Figure 4B shows the corresponding example for FHC. This example has much more clearly defined FHC landmarks, showing a much lower standard deviation. This also shows an example in which the distribution of measurements indicates 100% confidence that the patient’s hip is diagnosed as healthy.

3.2.1 Uncertainty

Uncertainty correlation: The mean and FHC predicted by the model and CombiMAP for each patient hip scan are strongly correlated (r = 0.855 and 0.995, respectively, in Figure 5). The standard deviations of the model and CombiMAP show a weak correlation for the angle (r = 0.389; see Figure 5). The standard deviation correlation for FHC when comparing the model and CombiMAP was slightly higher than the angle, showing moderate correlation (r = 0.589). We also note clustering in the scatter plots; therefore, the PCC values should be used only as a reference.

Figure 5

Inter-rater variability: The MAAD between CombiMAP and the reference expert is (Table 5). The model and the reference expert comparison shows a slightly lower MAAD of . As shown in Table 5, the MAFD is similar between the reference expert and the model (1.04%) and between the reference expert and CombiMAP (0.87%).

Table 5

MethodMAAD (degrees)MAFD (%)
Model1.591.04
CombiMAP3.770.87

MAAD and MAFD between the reference expert and each method (CombiMAP and the model), evaluated separately.

We refer to the CombiMAP values in this table as the “inter-rater variability.”

3.2.2 Confidence

Confidence correlation: There is a strong correlation (r = 0.928 and 0.966, for the angle and FHC, respectively, as seen in Figure 6 using the decision boundary threshold). As described in Section 3.2.1.1, the observed clustering should be considered when interpreting the Pearson correlation coefficients.

Figure 6

4 Discussion

4.1 Automated landmark-based measurement

When comparing automated methods, many studies report landmark errors in millimetres, but these values are not directly comparable without knowledge of the pixel size. By reporting errors in pixels, we can make meaningful comparisons across datasets. Where pixel spacing is unavailable, pixel errors provide the only common basis for comparison across studies. However, such comparisons should be interpreted with caution, as differences in image resolution and acquisition protocols may influence the correspondence between pixel and physical distances. Our best-performing model achieved an average mean radial error (aMRE) of 0.64 mm (9.07 pixels), which is within the range reported in the literature (0.59–1.22 mm). On the external datasets, errors were slightly higher (14.7–16.5 pixels), indicating that even minor preprocessing steps, such as image resizing and rounding before model input and after output, can influence performance. Future work can further reduce these discrepancies by avoiding rounding and carefully preserving pixel-level information.

Clinical inter-rater-variability provides a practical benchmark for acceptable error in landmark localisation for DDH. Previous work measured inter-rater variability of approximately 6–7 pixels for the apex point [44], highlighting the inherent difficulty in consistently placing anatomical landmarks. Our method shows a slightly larger difference (nine pixels), which is expected as we consider multiple landmarks, including more challenging points such as the labrum, whereas the apex point has clearer boundaries. By using inter-rater variability as a reference for landmark localisation errors, we contextualise our results relative to human-level performance, demonstrating that our method remains clinically meaningful despite slightly higher errors.

This study is the first to evaluate the “agreement” of the FHC method, establishing key reference values for future research. Unsurprisingly, the percentage of the test set falling within and was the highest for the main dataset (see Table 2). Overall, the external datasets showed lower metrics compared to the main dataset, although performance improved with the HRNet (40–60) relative to previous UNet++ architecture [34–44, [17]]. Consistent with the agreement, FHC metrics indicate that the model had greater difficulty generalising to Milton Keynes University Hospital (MKUH) than to the Royal National Orthopaedic Hospital (RNOH) (Table 3). Although the proposed method improves upon previous work evaluating landmark-based DDH measurements on external datasets [42], the external datasets were collected from referral hospitals using different ultrasound scanners, which may contribute to domain shift. Furthermore, ongoing work, beyond the scope of the present study, is investigating the influence of demographic differences between cohorts on model generalisation across external datasets.

4.2 Uncertainty and confidence

The mean absolute angle difference (MAAD) in this study was lower than in prior reports [18] ( for the model and for CombiMAP vs. and previously), likely reflecting network improvements (HRNet vs. UNet++) and higher-resolution input images ( vs. ), with corresponding MAFD values of 1.04 and 0.87. This work is the first to review a model mean absolute FHC percentage difference (MAFD), creating both a clinical (CombiMAP) and model performance baseline for future evaluations of the FHC method.

Interestingly, the MAAD measured on the model’s test set (, Table 5) was lower than that obtained when using the image centre alone (; Table 2). A similar pattern was observed for FHC, which improved from 1.25 using the model’s hottest point to 1.04 when employing the Monte Carlo-like averaging approach (Tables 3, 5). While part of this difference may be due to variations in the test set size, the results suggest that averaging multiple sampled predictions enhances robustness and reliability compared to relying on a single-point landmark location.

This work is the first to report inter-rater variability among 10 experts for DDH screening ( for the Graf method and 0.87 for the FHC method; see Table 5). Establishing this variability is critical as a reference baseline when developing automated methods, as their achievable performance is fundamentally bounded by the level of disagreement observed among clinical experts. A more detailed assessment of the measurement differences between individual clinicians is beyond the scope of the present technical article. Such analyses are currently being undertaken by our clinical collaborators, and the resulting clinical conclusions will be reported in a future medical publication.

The mean estimates predicted by the model and CombiMAP are strongly correlated for the angle and FHC (r = 0.855 and 0.995; Figure 5). This stronger correlation for FHC may be because the FHC exhibits less variation when calculated with only the -axis component considered. Removing variations in the horizontal direction result in lower output variability.

Here, the confidence should not be interpreted as confidence in a traditional manner: in Section 2.3.2, as required by the clinicians in the screening process, we have defined confidence as how “sure” the algorithm is that the patient’s hip is on the healthy side of the decision boundary. Thus, the observed agreement we see suggests that the model and clinicians assess patient hip scans similarly with respect to the clinical decision threshold, rather than simply expressing similar certainty in their classifications. This correlation can increase clinician trust in the model, as it provides a clear measure of how “sure” the model is in its predictions of healthy or unhealthy for screening, which we have shown to correlate strongly with human expert confidence.

4.2.1 Limitations

Although the proposed framework generalises to landmark-based clinical measurements, it was evaluated only on DDH ultrasound images and should be validated on additional anatomical landmarks, imaging modalities, and clinical applications. In addition, external evaluation was limited to two relatively small datasets, and differences in image acquisition, scanner characteristics, and unavailable pixel size information restricted direct comparison of some localisation metrics and may have contributed to reduced performance under domain shift.

A further limitation is that data partitioning was performed at the hip-scan level rather than at the patient level. Although each hip was assessed independently using only the geometric information visible in the individual scan, scans from the same patient are not fully independent, and their inclusion across different partitions may have introduced information leakage and resulted in optimistic performance estimates.

A limitation of this study is that only our method for uncertainty estimation (using a Monte Carlo-like dropout method) was evaluated. Future work should compare alternative uncertainty estimation methods (listed in Section 1.9) and their relationships with the observed inter-rater variability.

The assessment of clinician inter-rater variability in this analysis was limited by the available repeated clinical annotations. We have reported inter-rater variability to the best of our ability by comparing measurements to those of a reference expert. A larger, ongoing clinical study will provide a more detailed assessment of variability among clinicians and its relationship with model-derived uncertainty and model–clinician disagreement.

Similarly, a generalisation limitation of this work is that the clinician variability was estimated using annotations from 10 reviewers on a subset of images rather than the full dataset, and larger multi-centre studies would provide a more comprehensive estimate of clinical uncertainty. Finally, our confidence estimates quantify uncertainty arising from landmark localisation and measurement construction only but do not account for other sources of uncertainty (e.g., from image quality). Future work should validate this framework across larger multi-centre cohorts, verify the methods for additional clinical applications, improve robustness to domain shift, and extend confidence estimation to incorporate additional sources of uncertainty.

5 Conclusions and future work

While prior work automating landmark-based measurements has made incremental improvements in isolated model performance metrics, this study advances the combined interdisciplinary field by evaluating the entire clinical workflow, mirroring real clinical practice. The baseline benchmarks we establish in this work will enable meaningful comparison in future studies across all stages of the automated pipeline.

The current computer vision literature has focused primarily on quantitative performance metrics, without accounting for the clinical uncertainty and confidence inherent in these calculations. In this work, we develop methods for landmark-based measurement to explicitly incorporate uncertainty and confidence estimates in predictions. We demonstrate that our method’s estimates of two clinically established landmark-based measurements (Graf angle and FHC percentage) closely mirror those of clinical experts.

This study encourages a shift in emphasis, from focusing on numerical performance gains to systematically assessing model reliability and quantifying model confidence. The resulting confidence estimates can be applied directly in clinical settings to indicate cases requiring expert ultrasound scan review. This supports more reliable and accessible screening by increasing the number of patients who can be offered DDH screening, ultimately improving patient care.

Statements

Data availability statement

The data analysed in this study are subject to the following licenses/restrictions: All data were collected retrospectively from routine screening at Alder Hey Children’s Hospital. Requests to access these datasets should be directed to irina@cs.ox.ac.uk.

Ethics statement

The studies involving humans were approved by the NHS Health Research Authority (ID 316325; REC exemption Ref 23/HRA/0966). The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants’ legal guardians/next of kin in accordance with the national legislation and institutional requirements.

Author contributions

AC: Formal analysis, Writing – original draft, Project administration, Data curation, Resources, Visualization, Conceptualization, Writing – review & editing, Investigation, Validation, Software, Methodology. JW: Visualization, Investigation, Conceptualization, Validation, Software, Writing – review & editing, Formal analysis. DP: Funding acquisition, Writing – review & editing, Data curation, Supervision. IV: Formal analysis, Writing – review & editing, Methodology, Conceptualization, Project administration, Investigation, Supervision.

Funding

The author(s) declared that financial support was received for this work and/or its publication. This work was supported by conventional doctoral scholarships: a UK Engineering and Physical Sciences Research Council (EPSRC) (Grant number EP/W524311/1) and an Oxford Women in Computer Science scholarship.

Acknowledgments

We are grateful to Abhinav Singh for securing the data used in this project. The approval was obtained from the NHS Health Research Authority (IRAS ID 316325). Due to the anonymous datasets, the project was REC Exempt (Ref 23/HRA/0966). We extend gratitude to RAIQC Ltd. for the use of the viewing platform and to all clinicians involved in the annotation process. The authors would like to acknowledge the use of the University of Oxford Advanced Research Computing (ARC) facility in carrying out this work [45].

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence, and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1.

    ChenBXuQWangLLeungSChungJLiS. An automated and accurate spine curve analysis system. IEEE Access. (2019) 7:124596–605. 10.1109/ACCESS.2019.2938402

  • 2.

    McCouatJVoiculescuIGlyn-JonesS. Automatically diagnosing hip conditions from x-rays using landmark detection. In: 2021 IEEE 18th international symposium on biomedical imaging (ISBI) (IEEE) (2021), 179–82.

  • 3.

    JoCHwangDKoSYangMHLeeMCHanHS, et al. Deep learning-based landmark recognition and angle measurement of full-leg plain radiographs can be adopted to assess lower extremity alignment. Knee Surg Sports Traumatol Arthrosc. (2023) 31:1388–97. 10.1007/s00167-022-07124-x

  • 4.

    PrzystalskiKPaleczekASzustakowskiKWawrykaPJungiewiczMZalewskiM, et al. Automated correction angle calculation in high tibial osteotomy planning. Sci Rep. (2023) 13:12876.

  • 5.

    KhattakMBownessJSYonisRKierkegaardPMcGregorAPerryDC. Navigating the barriers and facilitators to implementation of ai in healthcare: a scoping review. Bone Joint J. (2025) 107-B:666–72. 10.1302/0301-620X.107B7.BJJ-2024-1570.R1

  • 6.

    Di ViaROdoneFPastoreVP. Self-supervised pre-training with diffusion model for few-shot landmark detection in x-ray images. In: Proceedings of the IEEE/CVF winter conference on applications of computer vision (WACV) (IEEE) (2025), 3886–96.

  • 7.

    PatelNClementAWyattJDi ViaRMarinelliDCiranniM, et al. A handful of data: evaluating few-shot incremental landmark detection. In: Image analysis and processing—ICIAP 2025: 23rd international conference, Rome, Italy, September 15–19, 2025, proceedings, part II (Cham: Springer) (2025), Lecture Notes in Computer Science, 16168, 127–39. 10.1007/978-3-032-10192-1_11

  • 8.

    UlziibatMMunkhuuBSchmidRBaumannTEssigS. Implementation of a nationwide universal ultrasound screening programme for developmental dysplasia of the neonatal hip in Mongolia. J Child Orthop. (2020) 14:273–80. 10.1302/1863-2548.14.200029

  • 9.

    RoposchALiuLQHeftiFClarkeNMWedgeJH. Standardized diagnostic criteria for developmental dysplasia of the hip in early infancy. Clin Orthop Relat Res. (2011) 469:3451–61. 10.1007/s11999-011-2066-9

  • 10.

    Al-EssaRSAljahdaliFHAlkhilaiwiRMPhilipWJawadiAHKhoshhalKI. Diagnosis and treatment of developmental dysplasia of the hip: a current practice of paediatric orthopaedic surgeons. J Orthop Surg. (2017) 25:2309499017717197. 10.1177/2309499017717197

  • 11.

    MorinCHarckeHMacEwenG. The infant hip: real-time US assessment of acetabular development. Radiology. (1985) 157:673–7. 10.1148/radiology.157.3.3903854

  • 12.

    TerjesenTBredlandTBergV. Ultrasound for hip assessment in the newborn. J Bone Joint Surg Br Vol. (1989) 71-B:767–73. 10.1302/0301-620X.71B5.2684989

  • 13.

    HarckeHTPruszczynskiB. Hip ultrasound for developmental dysplasia: the 50% rule. Pediatr Radiol. (2017) 47:817–21. 10.1007/s00247-017-3802-4

  • 14.

    GrafR. Fundamentals of sonographic diagnosis of infant hip dysplasia. J Pediatr Orthop. (1984) 4:735–40. 10.1097/01241398-198411000-00015

  • 15.

    RoposchAGrafRWrightJG. Determining the reliability of the graf classification for hip dysplasia. Clin Orthop Relat Res. (2006) 447:119–24. 10.1097/01.blo.0000203475.73678.be

  • 16.

    ChangWCHsuKHLoIFLiaoKHSuYP. Interobserver agreement and clinical disparity between the Graf method and femoral head coverage measurement in developmental dysplasia of the hip screening: a prospective observational study of 198 newborns. Medicine. (2021) 100:e26291. 10.1097/MD.0000000000026291

  • 17.

    ClementASinghAPerryDVoiculescuI. Improving automated ultrasound infant hip screening using an integrated clinical classification loss. In: Annual conference on medical image understanding and proceedings of medical image understanding and analysis (Springer) (2024), 14860, 382–97.

  • 18.

    ClementAWilloughbyJVoiculescuI. Confidence in angle predictions for clinical decision support. In: Proceedings of medical image computing and computer-assisted intervention—MICCAI 2025 (Springer Nature Switzerland) (2025), LNCS 15974, 116–24.

  • 19.

    LeeSWYeHULeeKJJangWYLeeJHHwangSM, et al. Accuracy of new deep learning model-based segmentation and key-point multi-detection method for ultrasonographic developmental dysplasia of the hip (DDH) screening. Diagnostics. (2021) 11:1174. 10.3390/diagnostics11071174

  • 20.

    GolanDDonnerYMansiCJaremkoJLRamachandranM. Fully automating Graf’s method for DDH diagnosis using deep convolutional neural networks. In: Deep learning and data labeling for medical applications: first international workshop, LABELS 2016, and second international workshop, DLMIA 2016, held in conjunction with MICCAI 2016, Athens, Greece, October 21, 2016, proceedings 1 (Springer) (2016), 130–41.

  • 21.

    HuXWangLYangXZhouXXueWCaoY, et al. Joint landmark and structure learning for automatic evaluation of developmental dysplasia of the hip. IEEE J Biomed Health Inform. (2022) 26:345–58. 10.1109/JBHI.2021.3087494

  • 22.

    HuangTShiJLiJWangJDuJShiJ. Involution transformer based U-Net for landmark detection in ultrasound images for diagnosis of infantile DDH. IEEE J Biomed Health Inform. (2024) 28(8):4797–809. 10.1109/JBHI.2024.3390241

  • 23.

    LeeYSKimYJRyuJWLeeSYKimKG. Automated neonatal hip ultrasound system for diagnosing developmental dysplasia of hips using assistive AI. J Imaging Inform Med. (2025) 39:1–14.

  • 24.

    HuangTShiJJinGLiJWangJDuJ, et al. Topological GCN for improving detection of hip landmarks from B-mode ultrasound images. In: International conference on medical image computing and computer-assisted intervention (Springer) (2024), 692–701.

  • 25.

    ChenYPFanTYChuCCLinJJJiCYKuoCF, et al. Automatic and human level Graf’s type identification for detecting developmental dysplasia of the hip. Biomed J. (2024) 47:100614. 10.1016/j.bj.2023.100614

  • 26.

    LiangniH. CCMT: cross collaboration mult-task network for neonatal hip bone intelligent diagnosis. In: 2024 IEEE 20th international symposium on biomedical imaging (ISBI) (IEEE) (2024), 1–5.

  • 27.

    SunKXiaoBLiuDWangJ. Deep high-resolution representation learning for human pose estimation. In: CVPR (2019), 5693–703.

  • 28.

    LiuMLiuRShuJLiuQZhangYJiangL. AutoDDH: a dual-attention multi-task network for grading developmental dysplasia of the hip in ultrasound images. Vis Comput. (2025) 41:1–13.

  • 29.

    ChenTZhangYWangBWangJCuiLHeJ, et al. Development of a fully automated Graf standard plane and angle evaluation method for infant hip ultrasound scans. Diagnostics. (2022) 12:1423. 10.3390/diagnostics12061423

  • 30.

    McCouatJVoiculescuI. Contour-hugging heatmaps for landmark detection. In: 2022 IEEE/CVF conference on computer vision and pattern recognition (CVPR) (2022), 20565–73. 10.1109/CVPR52688.2022.01994

  • 31.

    WyattJVoiculescuI. Optimising for the unknown: domain alignment for cephalometric landmark detection. arXiv [Preprint]. arXiv:2410.04445 (2024).

  • 32.

    ThalerFPayerCUrschlerMSternD. Data from: Modeling annotation uncertainty with Gaussian heatmaps in landmark localization. (2021).

  • 33.

    ChaiYBoudaliAMMaesVWalterWL. Clinical benchmark dataset for AI accuracy analysis: quantifying radiographic annotation of pelvic tilt. Sci Data. (2024) 11:1162. 10.1038/s41597-024-04003-7

  • 34.

    HuangBXiaBQianJZhouXZhouXLiuS, et al. Artificial AI-assisted ultrasound diagnosis on infant developmental dysplasia of the hip under constrained computational resources. J Ultrasound Med. (2023) 42:1235–48. 10.1002/jum.16133

  • 35.

    ZouKChenZYuanXShenXWangMFuH. A review of uncertainty estimation and its application in medical imaging. Meta Radiol. (2023) 1:100003. 10.1016/j.metrad.2023.100003

  • 36.

    MasonDscaramallionmrbean-bremenrhaxtonSueverJPapadopoulos OrfanosDet al. (2025). Pydicom: Pydicom v2.4.5 [Computer software]. Zenodo. Available online at: https://zenodo.org/records/19134308 (Accessed January 05, 2025).

  • 37.

    The GIMP Development Team. Data from: GIMP: GNU image manipulation program. Computer software (2024). Available online at: https://www.gimp.org (Accessed June 11, 2024).

  • 38.

    RAIQC Ltd. Data from: RAIQC: report and image quality control (web-based medical imaging simulation platform). Web-based clinical training and assessment tool—for medical image interpretation, developed at Oxford University Hospitals and commercialised by RAIQC Ltd. (2025). Available online at: https://www.raiqc.com (Accessed August 23, 2024).

  • 39.

    Van der WaltSSchönbergerJLNunez-IglesiasJBoulogneFWarnerJDYagerN, et al. scikit-image: image processing in Python. PeerJ. (2014) 2:e453. 10.7717/peerj.453

  • 40.

    JungAB. Data from: Imgaug (2018). Available online at: https://github.com/aleju/imgaug (Accessed January 01, 2024).

  • 41.

    KingmaDP. Adam: a method for stochastic optimization. arXiv [Preprint]. arXiv:1412.6980 (2014).

  • 42.

    ClementASinghAVoiculescuI. Landmark-based screening: femoral head coverage and Graf classification in infant developmental dysplasia of the hip. In: European conference on computer vision (Springer) (2024), 1–14.

  • 43.

    StamperASinghAMcCouatJVoiculescuI. Infant hip screening using multi-class ultrasound scan segmentation. In: 2023 IEEE 20th international symposium on biomedical imaging (ISBI) (IEEE) (2023), 1–4.

  • 44.

    ShimizuHEndaKKoyanoHOgawaTTakahashiDTanakaS, et al. Diagnosis on ultrasound images for developmental dysplasia of the hip with a deep learning-based model focusing on signal heterogeneity in the bone region. Diagnostics. (2025) 15:403. 10.3390/diagnostics15040403

  • 45.

    RichardsA. Data from: University of Oxford advanced research computing. (2015). 10.5281/zenodo.22558

Glossary

CombiMAP-confidence:The confidence calculated for the combined heatmap (CombiMAP).Confidence:A quantitative estimate derived from an “uncertainty,” which can be used to quantify how “sure” an output is based on a defined method. In this work, confidence is defined as the probability mass lying on one side of a clinically meaningful decision boundary.Inter-rater-variability:The extent to which clinicians produce different results or judgments when evaluating the same case using the same annotation-based assessment methods.Localisation uncertainty:The uncertainty in the precise spatial placement of a landmark. If a clinician were asked to place the same landmark many times, the exact position would vary. The probability of a particular location decreases as one deviates further from the most likely point.Landmark-based measurement:The landmark-based assessment (calculation used) as a precursor to classifying a patient during clinical screening. In this work, we use “measurement” for an angle or a distance which are calculated from landmarks.Measurement uncertainty:The “uncertainty” of a measurement (e.g. angles and/or distances) when based on an annotation or landmark which contains localisation uncertainty.Model-confidence:The confidence calculated for the model.Self-confidence:A reported value of “confidence” expressed by a clinician when placing landmark annotations, reflecting their subjective confidence in their own assessment.Trust:A clinician’s belief in the model’s ability to deliver accurate, reliable and safe outcomes.

Summary

Keywords

confidence, landmark detection, landmark-based measurements, screening, uncertainty

Citation

Clement A, Willoughby J, Perry DC and Voiculescu I (2026) From landmark uncertainty to clinical confidence: screening for developmental dysplasia of the hip. Front. Med. Technol. 8:1914040. doi: 10.3389/fmedt.2026.1914040

Received

19 June 2026

Revised

02 September 2026

Accepted

07 September 2026

Published

04 November 2026

Volume

8 - 2026

Edited by

Roberto Duarte Coello, University of Edinburgh, United Kingdom

Reviewed by

Hamid Motallebzadeh, California State University, United States

Yuan Chai, Northeastern University, China

Updates

Copyright

*Correspondence: Allison Clement

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics