<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2023.1179145</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>A clinical study to evaluate the safe and effective use of a new, single use stethoscope cover to enable reduction in pathogen transmission during auscultation</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Nazari-Shafti</surname> <given-names>Timo Z.</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref><xref rid="aff3" ref-type="aff"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/776218/overview"/>
</contrib>
<contrib contrib-type="author"><name><surname>Meyborg</surname> <given-names>Heike</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author"><name><surname>Iske</surname> <given-names>Jasper</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref><xref rid="aff3" ref-type="aff"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author"><name><surname>Schloss</surname> <given-names>Maximilian</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author"><name><surname>Seeber</surname> <given-names>Fabian</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2295944/overview"/>
</contrib>
<contrib contrib-type="author"><name><surname>Friedrich</surname> <given-names>Aljona</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2240407/overview"/>
</contrib>
<contrib contrib-type="author"><name><surname>Exarchos</surname> <given-names>Vasileios</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author"><name><surname>Richter</surname> <given-names>Anja</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author"><name><surname>Falk</surname> <given-names>Volkmar</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref><xref rid="aff3" ref-type="aff"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Emmert</surname> <given-names>Maximilian Y.</given-names></name><xref rid="aff1" ref-type="aff"><sup>1</sup></xref><xref rid="aff2" ref-type="aff"><sup>2</sup></xref><xref rid="c001" ref-type="corresp"><sup>&#x002A;</sup></xref>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charit&#x00E9; (DHZC)</institution>, <addr-line>Berlin</addr-line>, <country>Germany</country></aff>
<aff id="aff2"><sup>2</sup><institution>Charit&#x00E9; &#x2013; Universit&#x00E4;tsmedizin Berlin, Corporate Member of Freie Universit&#x00E4;t Berlin and Humboldt-Universit&#x00E4;t zu Berlin, and Berlin Institute of Health</institution>, <addr-line>Berlin</addr-line>, <country>Germany</country></aff>
<aff id="aff3"><sup>3</sup><institution>German Centre for Cardiovascular Research (DZHK), Partner Site Berlin</institution>, <addr-line>Berlin</addr-line>, <country>Germany</country></aff>
<author-notes>
<fn id="fn0001" fn-type="edited-by">
<p>Edited by: Kevin Willy, University Hospital M&#x00FC;nster, Germany</p>
</fn>
<fn id="fn0002" fn-type="edited-by">
<p>Reviewed by: Mariann Gy&#x00F6;ngy&#x00F6;si, Medical University of Vienna, Austria; Daniel Engelman, Baystate Medical Center, United States</p>
</fn>
<corresp id="c001">&#x002A;Correspondence: Maximilian Y. Emmert, <email>maximilian.emmert@dhzccharite.de</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>22</day>
<month>06</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>10</volume>
<elocation-id>1179145</elocation-id>
<history>
<date date-type="received">
<day>10</day>
<month>03</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>15</day>
<month>05</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2023 Nazari-Shafti, Meyborg, Iske, Schloss, Seeber, Friedrich, Exarchos, Richter, Falk and Emmert.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Nazari-Shafti, Meyborg, Iske, Schloss, Seeber, Friedrich, Exarchos, Richter, Falk and Emmert</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<sec>
<title>Objectives</title>
<p>Stethoscopes carry a significant risk for pathogen transmission. Here, the safe use and performance of a new, non-sterile, single-use stethoscope cover (SC), that is impermeable for pathogens, was investigated by different healthcare professionals (HCPs) in the postoperative care setting of an intensive care unit (ICU).</p>
</sec>
<sec>
<title>Methods</title>
<p>Fifty-four patients underwent routine auscultations with the use of the SC (Stethoglove<sup>&#x00AE;</sup>, Stethoglove GmbH, Hamburg, Germany). The participating HCPs (<italic>n</italic>&#x2009;=&#x2009;34) rated each auscultation with the SC on a 5-point Likert scale. The mean ratings of acoustic quality and the SC handling were defined as primary and secondary performance endpoint.</p>
</sec>
<sec>
<title>Results</title>
<p>534 auscultations with the SC were performed (average 15.7/user) on the lungs (36.1%), the abdomen (33.2%), the heart (28.8%), or other body-sites (1.9%). No adverse device-effects occurred. The acoustic quality was rated at 4.2&#x2009;&#x00B1;&#x2009;0.7 (mean) with a total of 86.1% of all auscultations being rated at least as 4/5, and with no rating as below 2. The SC handling was rated at 3.7&#x2009;&#x00B1;&#x2009;0.8 (mean) with a total of 96.4% of all auscultations being rated at least 3/5.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Using a real-world setting, this study demonstrates that the SC can be safely and effectively used as cover for stethoscopes during auscultation. The SC may therefore represent a useful and easy-to-implement tool for preventing stethoscope-mediated infections.</p>
<p><bold>Study Registration</bold>: EUDAMED no. CIV-21-09-037762.</p>
</sec>
</abstract>
<kwd-group>
<kwd>stethoscope</kwd>
<kwd>nosocomial infections</kwd>
<kwd>auscultation</kwd>
<kwd>transmission</kwd>
<kwd>polymer</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="6"/>
<equation-count count="0"/>
<ref-count count="18"/>
<page-count count="9"/>
<word-count count="5674"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Intensive Care Medicine and Anesthesiology</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="sec5" sec-type="intro">
<title>Introduction</title>
<p>Healthcare-associated infections (HAIs) represent a significant risk for patients (<xref ref-type="bibr" rid="ref1">1</xref>). In the United States, the Center for Disease Control (CDC) reports that about 1.7 million patients are estimated to be affected by HAIs every year while they are undergoing in-hospital treatment for other health problems, and about 100,000 patients (approx. 6%) are dying from such HAIs (<xref ref-type="bibr" rid="ref2">2</xref>). Widely regarded as the &#x201C;physician&#x2019;s third hand&#x201D; the stethoscope plays a critical role in the transmission of common pathogens such as gram positive bacilli (12%), gram-negative bacteria (9%), and gram-positive cocci (9%) (<xref ref-type="bibr" rid="ref3 ref4 ref5 ref6 ref7 ref8 ref9">3&#x2013;9</xref>). Most importantly, they harbor similar contamination levels as the HCP&#x2019;s hand (<xref ref-type="bibr" rid="ref2">2</xref>, <xref ref-type="bibr" rid="ref6">6</xref>, <xref ref-type="bibr" rid="ref10">10</xref>). Notably, with more than 5 billion auscultations per year in the US alone, it represents the most often used medical device in daily clinical practice (<xref ref-type="bibr" rid="ref2">2</xref>).</p>
<p>Stethoscopes are crucial for both, in hospital and outpatient environments. They are not only used for standard physical assessments, but also for the examination of special medical conditions such as the diagnosis of abdominal or heart diseases or during routine postoperative care, e.g., in intensive care units (ICU).</p>
<p>Disinfection of stethoscopes with isopropyl alcohol is recommended and may be effective at eliminating many pathogens (<xref ref-type="bibr" rid="ref3">3</xref>, <xref ref-type="bibr" rid="ref5">5</xref>, <xref ref-type="bibr" rid="ref11">11</xref>). However, even though stethoscope cleaning guidelines and recommendations from the CDC are available (i.e., continuous wiping with isopropyl alcohol for at least 60&#x2009;s), the overall compliance of health care professionals (HCPs) in the daily clinical routine is reported to be extremely low (<xref ref-type="bibr" rid="ref4">4</xref>, <xref ref-type="bibr" rid="ref12">12</xref>, <xref ref-type="bibr" rid="ref13">13</xref>).</p>
<p>A recent study from Boulee and colleagues found that stethoscopes are most often not cleaned between patient auscultations. Moreover, in cases where cleaning was performed it only complied in 4% of the cases with the current CDC guidelines (<xref ref-type="bibr" rid="ref12">12</xref>, <xref ref-type="bibr" rid="ref14">14</xref>). The reasons for this non-compliance are multifactorial (e.g., lack of time, material, and reminders) (<xref ref-type="bibr" rid="ref13">13</xref>). To date, many initiatives to improve stethoscope hygiene have widely failed, and commonly accepted &#x201C;best practices&#x201D; are yet to be developed. In addition, even if current stethoscope cleaning guidelines would be practiced, highly virulent pathogens such as methicillin-resistant <italic>S. aureus</italic> (MRSA) or <italic>C. difficile</italic> spores are likely to persist on the stethoscope diaphragm thereby posing a significant risk to the next patient (<xref ref-type="bibr" rid="ref15">15</xref>).</p>
<p>Alternative strategies to enhance stethoscope hygiene have been limited so far (<xref ref-type="bibr" rid="ref16">16</xref>). However, driven by the ongoing COVID-19 pandemic, the search for new stethoscope protection technologies and concepts has recently regained reasonable attention (<xref ref-type="bibr" rid="ref10">10</xref>). One promising approach are microbiological barriers (e.g., single-use, disposable covers) shielding the stethoscope diaphragm direct patient contact (<xref ref-type="bibr" rid="ref16">16</xref>, <xref ref-type="bibr" rid="ref17">17</xref>). However, while such concepts may indeed have the potential to improve stethoscope hygiene, they should not alter auscultation accuracy by impairing the acoustic quality of auscultation sounds. Available data is scarce in this regard (<xref ref-type="bibr" rid="ref17">17</xref>). Another important requirement for such a device is its ease of use as to enable simple and rapid implementation into the clinical routine workflow (<xref ref-type="bibr" rid="ref2">2</xref>).</p>
<p>Recently, a new non-sterile, single-use hygienic cover for stethoscopes (Stethoglove<sup>&#x00AE;</sup>, Stethoglove GmbH, Hamburg, Germany) has been developed. It is impermeable for microorganisms thereby preventing stethoscope-mediated patient-to-patient transmission of pathogens and preserves the acoustic quality of auscultations. The SC can be easily pulled over the stethoscope&#x2019;s bell, part of the tube(s), while being held in the hand of the user to also shield the operating hand during auscultation.</p>
<p>In the present clinical study, the safe use and performance of the new SC was investigated by different HCPs under real-life conditions in the daily routine setting of an ICU for cardiac surgery patients.</p>
</sec>
<sec id="sec6">
<title>Patients and methods</title>
<sec id="sec7">
<title>Study design and objectives</title>
<p>The aim of this single-arm, open-label clinical study was to investigate the safe use and performance of the SC by HCPs under real-life conditions in an ICU for cardiovascular surgery patients. The objectives of the study were to assess (1.) the acoustic quality of auscultations with the SC (primary performance endpoint) and (2.) the overall usability of the SC (secondary performance endpoint) in the daily clinical routine by different HCPs (user groups) including physicians and nurses which were further characterized by their level of clinical experience. The study was approved by the local ethics committee (21-702-MP Mono-IVE17) and the federal authority (94.1-03-5,660-13,526).</p>
</sec>
<sec id="sec8">
<title>Patients and study course</title>
<p>Upon hospital admission on the day prior to their elective cardiovascular surgery adult patients (&#x2265;18&#x2009;years) were asked for informed consent to participate in the study. Patients who provided informed consent were screened for inclusion and exclusion criteria (see definitions in <xref rid="sec33" ref-type="sec">Supplementary file</xref>). In included patients, the participating users performed auscultations as part of their standard postoperative care with the SC.</p>
<p>After each auscultation the users entered the following information and rating on a study-specific and access-restricted page embedded into the patients&#x2019; electronic medical record:</p>
<list list-type="order">
<list-item>
<p>Auscultated organ or body site</p>
<list list-type="order">
<list-item>
<p>Heart</p>
</list-item>
<list-item>
<p>Lung</p>
</list-item>
<list-item>
<p>Abdomen</p>
</list-item>
<list-item>
<p>Other</p>
</list-item>
</list>
</list-item>
<list-item>
<p>Rating of the acoustic quality of the auscultation with the SC (on a 5-point Likert scale)</p>
</list-item>
</list>
<table-wrap position="anchor" id="tab1">
<table frame="hsides" rules="groups">
<tbody>
<tr>
<td align="left" valign="top">1</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">4</td>
<td align="center" valign="top">5</td>
</tr>
<tr>
<td align="left" valign="top">Poor</td>
<td align="center" valign="top">Moderate</td>
<td align="center" valign="top">Reasonable</td>
<td align="center" valign="top">Good</td>
<td align="center" valign="top">Very good</td>
</tr>
</tbody>
</table>
</table-wrap>
<list list-type="order">
<list-item>
<p>Rating of the SC handling as part of the routine working practice (on a 5-point Likert scale)</p>
</list-item>
</list><table-wrap position="anchor" id="tab2">
<table frame="hsides" rules="groups">
<tbody>
<tr>
<td align="left" valign="top">1</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">4</td>
<td align="center" valign="top">5</td>
</tr>
<tr>
<td align="left" valign="top">Poor</td>
<td align="center" valign="top">Moderate</td>
<td align="center" valign="top">Reasonable</td>
<td align="center" valign="top">Good</td>
<td align="center" valign="top">Very good</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec9">
<title>Users</title>
<p>A total of 34 physicians and nurses with different levels of professional experience participated in this study and were assigned to one of the following groups:</p>
<p><underline>User group 1:</underline> Fully trained physicians (e.g., senior physician, board-certified physician, medical specialist, physicians with at least 8&#x2009;years of working experience) (<italic>n</italic>&#x2009;=&#x2009;8).</p>
<p><underline>User group 2:</underline> Physicians in specialty training (e.g., residents) (<italic>n</italic>&#x2009;=&#x2009;7).</p>
<p><underline>User group 3:</underline> Fully trained nurses with at least 10&#x2009;years of working experience (<italic>n</italic>&#x2009;=&#x2009;10).</p>
<p><underline>User group 4:</underline> Fully trained nurses with less than 10&#x2009;years of working experience (<italic>n</italic>&#x2009;=&#x2009;9).</p>
</sec>
<sec id="sec10">
<title>Device description</title>
<p>The SC (Stethoglove GmbH, Hamburg, Germany) is a hygienic stethoscope cover and a safe and effective solution to minimize the risk of patient-to-patient infections caused by contaminated stethoscopes in a health care environment (<xref rid="fig1" ref-type="fig">Figure 1</xref>, product images).</p>
<fig position="float" id="fig1">
<label>Figure 1</label>
<caption>
<p>Product image of single use glove.</p>
</caption>
<graphic xlink:href="fmed-10-1179145-g001.tif"/>
</fig>
<p>The non-sterile, single-use glove is pulled over the stethoscope&#x2019;s bell and part of the tube(s), while held in the hand of the user (<xref rid="fig2" ref-type="fig">Figure 2</xref>, product handling images).</p>
<fig position="float" id="fig2">
<label>Figure 2</label>
<caption>
<p>Product handling images.</p>
</caption>
<graphic xlink:href="fmed-10-1179145-g002.tif"/>
</fig>
<p>The SC is made of thermoplastic urethane (TPU) and is latex-and powder-free. The TPU material is impermeable for microorganisms such as bacteria, fungi and viruses. Such impermeability was demonstrated with decontaminated stethoscope bells wrapped in a the SC cover, which were exposed for 30&#x2009;min to confluently grown bacterial (<italic>S. aureus</italic>, <italic>B. diminuta</italic>) and fungal (<italic>A. niger</italic>, <italic>C. albicans</italic>) cultures on agar plates. Swabbing of the unwrapped stethoscope diaphragm post exposure revealed no contaminations [internal report, unpublished data]. Viral impermeability was tested in accordance with Method C of ISO Norm 16,604 (2004) using the blood-borne pathogen Bacteriophage Phi-X1274. Cut-outs from four different areas of a the SC cover were exposed to the virus-containing suspension in a penetration cell and a sequence of pressures ranging from 0 to 20&#x2009;kpa was applied each for 5&#x2009;min. No virus penetration was detected [internal report, unpublished data].</p>
<p>Regarding acoustic quality the SC has demonstrated excellent transmission of auscultation sounds in both lab tests and a usability test with HCPs [unpublished data]. By combining this impermeability for microorganism with the preserved acoustic quality of auscultation sounds the SC ensures proper and safe patient-to-patient use of stethoscopes by HCPs in their day-to-day practice and thus improves patient protection from HAIs.</p>
</sec>
<sec id="sec11">
<title>Study endpoints</title>
<p>In this study the following performance and safety endpoints were defined:</p>
<list list-type="bullet">
<list-item>
<p>The primary performance endpoint was the rating of the acoustic quality of auscultations with the SC by all users.</p>
</list-item>
<list-item>
<p>The secondary performance endpoint was the rating of the handling of the SC as part of the routine working practice by all users.</p>
</list-item>
<list-item>
<p>The safety endpoint was the frequency of observed adverse device effects or serious adverse device effects.</p>
</list-item>
</list>
<p>In addition, the influence of gender, BMI and auscultated organ/body site on the primary and secondary performance endpoints were evaluated.</p>
</sec>
<sec id="sec12">
<title>Sample size calculation and statistical analysis</title>
<p>The continuous parameter &#x201C;rating of the acoustic quality during auscultation measured on a 5-point Likert scale (poor, moderate, reasonable, good, very good)&#x201D; was used as primary performance endpoint. No verification of a pre-defined hypotheses was planned. Instead, a total of 508 recorded auscultations with the SC was calculated to be required based on the following assumptions: a sampling error of 5% (precision), a prognostic accuracy of 95% (reliability), an expected mean of 4 (assessment of acoustic quality, &#x201C;good&#x201D;), and a variance of 2.3 points (homogeneity).</p>
<p>Both the primary and secondary performance endpoints were first evaluated descriptively and then stratified by the following influencing factors: patient gender, BMI and auscultated organ/body site. All analyses were performed within all users, and within each user group. Missing values were not replaced.</p>
<p>All measured differences between groups were investigated for numeric variables by means of a two-sided <italic>t</italic>-test for independent samples (comparison of 2 groups) and a one-factorial ANOVA (Welch-Test, comparison of more than 2 groups) with a type I error of 0.05. Since no formal hypothesis testing was done, all <italic>p</italic>-values were interpreted in a descriptive manner.</p>
</sec>
</sec>
<sec id="sec13" sec-type="results">
<title>Results</title>
<sec id="sec14">
<title>Baseline characteristics, demographics, and safety</title>
<p>A total of 54 patients were enrolled in this study and 534 auscultations with the SC were performed with an average of 9.9 auscultations per patient. Patient characteristics are shown in <xref rid="tab3" ref-type="table">Table 1</xref>.</p>
<table-wrap position="float" id="tab3">
<label>Table 1</label>
<caption>
<p>Patient demographics.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Variable</th>
<th/>
<th align="center" valign="top">Total patients (<italic>N</italic>&#x2009;=&#x2009;54)</th>
<th align="center" valign="top">Percentage (%)</th>
<th align="center" valign="top">Statistics</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="top" rowspan="2">Gender</td>
<td align="left" valign="top">Female</td>
<td align="center" valign="top">15</td>
<td align="char" valign="top" char=".">27.8</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Male</td>
<td align="center" valign="top">39</td>
<td align="char" valign="top" char=".">72.2</td>
<td/>
</tr>
<tr>
<td align="left" valign="top" rowspan="9">Body mass index</td>
<td align="left" valign="top">
<italic>N</italic>
</td>
<td/>
<td/>
<td align="char" valign="top" char=".">54</td>
</tr>
<tr>
<td align="left" valign="top">Mean&#x2009;&#x00B1;&#x2009;SD</td>
<td/>
<td/>
<td align="char" valign="top" char=".">27.8&#x2009;&#x00B1;&#x2009;5.2</td>
</tr>
<tr>
<td align="left" valign="top">Median</td>
<td/>
<td/>
<td align="char" valign="top" char=".">27.4</td>
</tr>
<tr>
<td align="left" valign="top">Range (Min&#x2013;Max)</td>
<td/>
<td/>
<td align="char" valign="top" char=".">19.8&#x2013;43.8</td>
</tr>
<tr>
<td align="left" valign="top">Normal weight (18.5&#x2013;24.9)</td>
<td align="center" valign="top">19</td>
<td align="char" valign="top" char=".">35.2</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Overweight (25.0&#x2013;29.9)</td>
<td align="center" valign="top">19</td>
<td align="char" valign="top" char=".">35.2</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Class I obesity (overweight) (30.0&#x2013;34.9)</td>
<td align="center" valign="top">13</td>
<td align="char" valign="top" char=".">24.1</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Class II obesity (obesity) (35.0&#x2013;39.9)</td>
<td align="center" valign="top">0</td>
<td align="char" valign="top" char=".">0.0</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Class III obesity (extreme obesity) (&#x2265;40.0)</td>
<td align="center" valign="top">3</td>
<td align="char" valign="top" char=".">5.6</td>
<td/>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><sup>&#x002A;</sup>SD, standard deviation.</p>
</table-wrap-foot>
</table-wrap>
<p>More males (<italic>n</italic>&#x2009;=&#x2009;39) than females (<italic>n</italic>&#x2009;=&#x2009;15) participated in this investigation which represents the typical gender distribution in cardiovascular patients. The mean BMI in the patient cohort was 27.8&#x2009;&#x00B1;&#x2009;5.2&#x2009;kg/cm<sup>2</sup>. The majority of patients (<italic>n</italic>&#x2009;=&#x2009;35) were overweight, 13 patients suffered from class I and 3 patients from class III obesity.</p>
<p>The rate of auscultations per organ and body site, were evenly distributed between lung (36.1%), abdomen (33.2%), and heart (28.8%), while only 1.9% of the auscultations were performed at other body sites (e.g., carotid artery) (<xref rid="tab4" ref-type="table">Table 2</xref>). No adverse device effects (ADEs) were reported during the study.</p>
<table-wrap position="float" id="tab4">
<label>Table 2</label>
<caption>
<p>Distribution of auscultations with the SC by body site and user group.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Variable</th>
<th/>
<th align="center" valign="top">Total auscultations (<italic>N</italic>&#x2009;=&#x2009;534)</th>
<th align="center" valign="top">Percentage (%)</th>
<th/>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="top" rowspan="5">Organ/Body site</td>
<td align="left" valign="top">Abdomen</td>
<td align="center" valign="middle">177</td>
<td align="char" valign="middle" char=".">33.2</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Heart</td>
<td align="center" valign="middle">154</td>
<td align="char" valign="middle" char=".">28.8</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Lung</td>
<td align="center" valign="middle">193</td>
<td align="char" valign="middle" char=".">36.1</td>
<td/>
</tr>
<tr>
<td align="left" valign="top">Other</td>
<td align="center" valign="middle">10</td>
<td align="char" valign="middle" char=".">1.9</td>
<td/>
</tr>
<tr>
<td/>
<td/>
<td/>
<td align="char" valign="top" char=".">Average no. per user</td>
</tr>
<tr>
<td align="left" valign="top" rowspan="5">User Group</td>
<td align="left" valign="top">No. 1: Fully trained physicians (<italic>N</italic>&#x2009;=&#x2009;8)</td>
<td align="center" valign="top">137</td>
<td align="char" valign="top" char=".">25.7</td>
<td align="char" valign="top" char=".">17.1</td>
</tr>
<tr>
<td align="left" valign="top">No. 2: Physicians in speciality training (<italic>N</italic>&#x2009;=&#x2009;7)</td>
<td align="center" valign="top">114</td>
<td align="char" valign="top" char=".">21.4</td>
<td align="char" valign="top" char=".">16.3</td>
</tr>
<tr>
<td align="left" valign="top">No. 3: Fully trained nurses with &#x2265;10&#x2009;years of experience (<italic>N</italic>&#x2009;=&#x2009;10)</td>
<td align="center" valign="top">152</td>
<td align="char" valign="top" char=".">28.5</td>
<td align="char" valign="top" char=".">13.8</td>
</tr>
<tr>
<td align="left" valign="top">No. 4: Fully trained nurses with &#x003C;10&#x2009;years of experience (<italic>N</italic>&#x2009;=&#x2009;9)</td>
<td align="center" valign="top">131</td>
<td align="char" valign="top" char=".">24.5</td>
<td align="char" valign="top" char=".">16.4</td>
</tr>
<tr>
<td align="left" valign="top">All (<italic>N</italic>&#x2009;=&#x2009;34)</td>
<td align="center" valign="top">534</td>
<td align="char" valign="top" char=".">100</td>
<td align="char" valign="top" char=".">15.7</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec15">
<title>Acoustic quality of auscultations with the SC</title>
<sec id="sec16">
<title>Primary performance endpoint</title>
<p>The mean rating of the acoustic quality of auscultations with the SC by all users was 4.2&#x2009;&#x00B1;&#x2009;0.7 (Median 4.0; range 2&#x2013;5) on a 5-point Likert scale (<xref rid="tab5" ref-type="table">Table 3</xref>). A total of 86.1% of all auscultations with the SC were rated at least&#x201D; good&#x201D; (score of 4 or higher) with comparable results across user groups ranging from 88.3% for fully trained physicians (group 1), 85.1% for physicians in speciality training (group 2), 87.5% for nurses with 10 or more years of professional experience (group 3), and 83.1% for nurses with less than of professional experience (group 4), respectively (<xref rid="tab5" ref-type="table">Table 3</xref>; <xref rid="fig3" ref-type="fig">Figure 3</xref>). No auscultation was rated as &#x201C;poor&#x201D; (score of 1). For two out of 534 auscultations no rating was recorded.</p>
<table-wrap position="float" id="tab5">
<label>Table 3</label>
<caption>
<p>Percentage of the SC handling rated as &#x201C;reasonable,&#x201D; &#x201C;good&#x201D;, and &#x201C;very good.&#x201D;</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="middle" rowspan="2">User group</th>
<th align="center" valign="middle" colspan="5">Ratings of handling (% and <italic>n</italic>)</th>
</tr>
<tr>
<th align="center" valign="middle">Mean&#x2009;&#x00B1;&#x2009;SD</th>
<th align="center" valign="middle">&#x201C;Reasonable&#x201D; (score of 3)</th>
<th align="center" valign="middle">&#x201C;Good&#x201D; (score of 4)</th>
<th align="center" valign="middle">&#x201C;Very good&#x201D; (score of 5)</th>
<th align="center" valign="middle">Combined</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">All users</td>
<td align="char" valign="top" char="(">3.7&#x2009;&#x00B1;&#x2009;0.8 (<italic>n</italic> =&#x2009;533<sup>&#x002A;</sup>)</td>
<td align="char" valign="middle" char="(">40.8% (<italic>n</italic> =&#x2009;218)</td>
<td align="char" valign="middle" char="(">34.6% (<italic>n</italic> =&#x2009;185)</td>
<td align="char" valign="middle" char="(">21.0% (<italic>n</italic> =&#x2009;112)</td>
<td align="char" valign="middle" char="(">96.4% (<italic>n</italic> =&#x2009;515)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 1</td>
<td align="char" valign="top" char="(">4.0&#x2009;&#x00B1;&#x2009;0.9 (<italic>n</italic> =&#x2009;136)</td>
<td align="char" valign="middle" char="(">32.9% (<italic>n</italic> =&#x2009;45)</td>
<td align="char" valign="middle" char="(">24.8% (<italic>n</italic> =&#x2009;34)</td>
<td align="char" valign="middle" char="(">39.4% (<italic>n</italic> =&#x2009;54)</td>
<td align="char" valign="middle" char="(">97.1% (<italic>n</italic> =&#x2009;133)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 2</td>
<td align="char" valign="top" char="(">3.7&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;114)</td>
<td align="char" valign="middle" char="(">34.2% (<italic>n</italic> =&#x2009;39)</td>
<td align="char" valign="middle" char="(">52.6% (<italic>n</italic> =&#x2009;60)</td>
<td align="char" valign="middle" char="(">10.5% (<italic>n</italic> =&#x2009;12)</td>
<td align="char" valign="middle" char="(">97.3% (<italic>n</italic> =&#x2009;111)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 3</td>
<td align="char" valign="top" char="(">3.8&#x2009;&#x00B1;&#x2009;0.8 (<italic>n</italic> =&#x2009;152)</td>
<td align="char" valign="middle" char="(">21.7% (<italic>n</italic> =&#x2009;33)</td>
<td align="char" valign="middle" char="(">50.0% (<italic>n</italic> =&#x2009;76)</td>
<td align="char" valign="middle" char="(">20.4% (<italic>n</italic> =&#x2009;31)</td>
<td align="char" valign="middle" char="(">92.1% (<italic>n</italic> =&#x2009;140)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 4</td>
<td align="char" valign="top" char="(">3.3&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;131)</td>
<td align="char" valign="middle" char="(">77.1% (<italic>n</italic> =&#x2009;101)</td>
<td align="char" valign="middle" char="(">11.5% (<italic>n</italic> =&#x2009;15)</td>
<td align="char" valign="middle" char="(">11.5% (<italic>n</italic> =&#x2009;15)</td>
<td align="char" valign="middle" char="(">100% (<italic>n</italic> =&#x2009;131)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><sup>&#x002A;</sup>For one out of 534 auscultations (0.2%) no rating was recorded.</p>
</table-wrap-foot>
</table-wrap>
<fig position="float" id="fig3">
<label>Figure 3</label>
<caption>
<p>Distribution of ratings of auscultation quality among the four user groups. User group 4: Fully trained nurses with &#x003C;10&#x2009;years of experience, user group 3: nurses with &#x003E;10&#x2009;years of experience, user group 3: Physicians in specialty training (e.g., residents), user group 1: Fully trained physicians (e.g., senior physician, board-certified physician, medical specialist, physicians with at least 8&#x2009;years of working experience).</p>
</caption>
<graphic xlink:href="fmed-10-1179145-g003.tif"/>
</fig>
</sec>
<sec id="sec17">
<title>Acoustic quality of auscultations with the SC stratified by gender, BMI, and auscultated organ/body site</title>
<p>The influence of the independent variables gender, BMI, and auscultated organ/body site on the rating of the acoustic quality of auscultations with the SC by all users was evaluated separately. The rating of the acoustic quality in male and female patients was comparable with a mean score of 4.2&#x2009;&#x00B1;&#x2009;0.7 in males and 4.0&#x2009;&#x00B1;&#x2009;0.7 in females (Median 4.0; range 2&#x2013;5 for both) (<xref ref-type="supplementary-material" rid="SM1">Supplementary Table S1</xref>).</p>
<p>When stratified by BMI the mean rating of the acoustic quality was 4.3&#x2009;&#x00B1;&#x2009;0.6 (for normal weight patients), 4.2&#x2009;&#x00B1;&#x2009;0.8 (for overweight patients), 4.0&#x2009;&#x00B1;&#x2009;0.6 (for class I obesity patients), and 3.8&#x2009;&#x00B1;&#x2009;0.8 (for class III obesity patients) (Median 4.0; range 2&#x2013;5 for all BMI groups) (<xref ref-type="supplementary-material" rid="SM1">Supplementary Table S2</xref>).</p>
<p>When stratified by auscultated organ/body site the mean rating of the acoustic quality was 4.3&#x2009;&#x00B1;&#x2009;0.7 for lungs, 4.2&#x2009;&#x00B1;&#x2009;0.7 for abdomen, and 4.1&#x2009;&#x00B1;&#x2009;0.6 for the heart (Median 4.0; range 2&#x2013;5 for all three). For &#x201C;other&#x201D; body sites including the carotid artery, femoral artery and stomach, a lower mean rating was assigned (3.3&#x2009;&#x00B1;&#x2009;0.7; Median 3.0; range 2&#x2013;4), however, the underlying number of auscultations was substantially lower than for the lung, abdomen and heart (<xref ref-type="supplementary-material" rid="SM1">Supplementary Table S3</xref>).</p>
</sec>
<sec id="sec18">
<title>Acoustic quality of auscultations with the SC by user groups</title>
<p>The ratings were consistent across all user groups, i.e., 4.2&#x2009;&#x00B1;&#x2009;0.7 for user groups 1&#x2013;3, and 4.0&#x2009;&#x00B1;&#x2009;0.7 for user group 4.</p>
</sec>
</sec>
<sec id="sec19">
<title>Evaluation of the SC usability (handling)</title>
<sec id="sec20">
<title>Secondary performance endpoint</title>
<p>The mean rating of the handling of the SC in the daily clinical routine by all users was 3.7&#x2009;&#x00B1;&#x2009;0.8 (Median 4.0; range 2&#x2013;5) (<xref rid="tab6" ref-type="table">Table 4</xref>). A total of 96.4% of all auscultations was rated to be at least&#x201D; reasonable&#x201D; by all users, while no auscultation was rated as &#x201C;poor&#x201D; (score of 1) (<xref rid="tab6" ref-type="table">Table 4</xref>; <xref rid="fig4" ref-type="fig">Figure 4</xref>). This suggests a high level of acceptability to use the SC throughout all user groups. No handling was rated as &#x201C;poor&#x201D; (score of 1). For one out of 534 auscultations no rating of the handling was recorded.</p>
<table-wrap position="float" id="tab6">
<label>Table 4</label>
<caption>
<p>Percentage of auscultations with the SC where the acoustic quality was rated as &#x201C;good&#x201D; and &#x201C;very good.&#x201D;</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="middle" rowspan="2">User group</th>
<th align="center" valign="middle" colspan="4">Ratings of acoustic quality (% and <italic>n</italic>)</th>
</tr>
<tr>
<th align="center" valign="middle">Mean&#x2009;&#x00B1;&#x2009;SD</th>
<th align="center" valign="middle">&#x201C;Good&#x201D; (score of 4)</th>
<th align="center" valign="middle">&#x201C;Very good&#x201D; (score of 5)</th>
<th align="center" valign="middle">Combined</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">All users</td>
<td align="char" valign="middle" char="(">4.2&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;532<sup>&#x002A;</sup>)</td>
<td align="char" valign="middle" char="(">53.2% (<italic>n</italic> =&#x2009;284)</td>
<td align="char" valign="middle" char="(">33.0% (<italic>n</italic> =&#x2009;176)</td>
<td align="char" valign="middle" char="(">86.1% (<italic>n</italic> =&#x2009;460)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 1</td>
<td align="char" valign="middle" char="(">4.2&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;135)</td>
<td align="char" valign="middle" char="(">53.3% (<italic>n</italic> =&#x2009;73)</td>
<td align="char" valign="middle" char="(">35.0% (<italic>n</italic> =&#x2009;48)</td>
<td align="char" valign="middle" char="(">88.3% (<italic>n</italic> =&#x2009;121)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 2</td>
<td align="char" valign="middle" char="(">4.2&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;114)</td>
<td align="char" valign="middle" char="(">46.5% (<italic>n</italic> =&#x2009;53)</td>
<td align="char" valign="middle" char="(">38.6% (<italic>n</italic> =&#x2009;44)</td>
<td align="char" valign="middle" char="(">85.1% (<italic>n</italic> =&#x2009;97)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 3</td>
<td align="char" valign="middle" char="(">4.2&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;152)</td>
<td align="char" valign="middle" char="(">50.0% (<italic>n</italic> =&#x2009;76)</td>
<td align="char" valign="middle" char="(">37.5% (<italic>n</italic> =&#x2009;57)</td>
<td align="char" valign="middle" char="(">87.5% (<italic>n</italic> =&#x2009;133)</td>
</tr>
<tr>
<td align="left" valign="middle">User group 4</td>
<td align="char" valign="middle" char="(">4.0&#x2009;&#x00B1;&#x2009;0.7 (<italic>n</italic> =&#x2009;131)</td>
<td align="char" valign="middle" char="(">62.6% (<italic>n</italic> =&#x2009;82)</td>
<td align="char" valign="middle" char="(">20.6% (<italic>n</italic> =&#x2009;27)</td>
<td align="char" valign="middle" char="(">83.2% (<italic>n</italic> =&#x2009;109)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><sup>&#x002A;</sup>For two out of 534 auscultations (0.3%) no rating was recorded.</p>
</table-wrap-foot>
</table-wrap>
<fig position="float" id="fig4">
<label>Figure 4</label>
<caption>
<p>Distribution of ratings of product handling among the four user groups. User group 4: Fully trained nurses with &#x003C;10&#x2009;years of experience, user group 3: nurses with &#x003E;10&#x2009;years of experience, user group 3: Physicians in specialty training (e.g., residents), user group 1: Fully trained physicians (e.g., senior physician, board-certified physician, medical specialist, physicians with at least 8&#x2009;years of working experience).</p>
</caption>
<graphic xlink:href="fmed-10-1179145-g004.tif"/>
</fig>
</sec>
<sec id="sec21">
<title>The SC handling stratified by gender, BMI, and auscultated body site of auscultation</title>
<p>The influence of the independent variables gender, BMI, and auscultated organ/body site on the rating of the SC handling was evaluated separately. The mean rating of the SC handling by all users was 3.8&#x2009;&#x00B1;&#x2009;0.9 for males and 3.5&#x2009;&#x00B1;&#x2009;0.7 for females (Median 4.0; range 2&#x2013;5 for both).</p>
<p>When stratified for BMI, the mean rating of the SC handling was 3.8&#x2009;&#x00B1;&#x2009;0.8 (for normal weight patients), 3.8&#x2009;&#x00B1;&#x2009;0.9 (for overweight patients), 3.6&#x2009;&#x00B1;&#x2009;0.7 (for class I obesity patients), and 3.2&#x2009;&#x00B1;&#x2009;0.5 (for class III obesity patients).</p>
<p>When stratified for auscultated organ/body site, the mean rating of the SC handling was 3.7&#x2009;&#x00B1;&#x2009;0.8 for lungs, 3.8&#x2009;&#x00B1;&#x2009;0.8 for hearts, and 3.7&#x2009;&#x00B1;&#x2009;0.8 for the abdomen (Median 4.0; range 2&#x2013;5 for all). For &#x201C;other&#x201D; body sites including the carotid artery, femoral artery and stomach, a lower mean rating was assigned (3.6&#x2009;&#x00B1;&#x2009;0.5), however, the underlying number of auscultations was substantially lower than for the lung, abdomen and heart.</p>
</sec>
<sec id="sec22">
<title>The SC handling by user group</title>
<p>The SC handling was rated &#x201C;reasonable to good&#x201D; by each of the four user groups (means ranging from 3.3&#x2009;&#x00B1;&#x2009;0.7 to 4.0&#x2009;&#x00B1;&#x2009;0.9).</p>
</sec>
</sec>
</sec>
<sec id="sec23" sec-type="discussions">
<title>Discussion</title>
<p>In this study, the performance and safe use of the SC, a new, non-sterile, single-use hygienic cover for stethoscopes, was demonstrated under real-life conditions in the routine setting of an ICU for postoperative care of cardiac surgery patients. In total, 534 auscultations of different body regions including lungs, heart and abdomen were performed with the SC and rated for acoustic quality and product handling.</p>
<sec id="sec24">
<title>The SC offers good acoustic quality of auscultations and an reasonable handling profile</title>
<p>The overall acoustic quality of auscultations with the SC was &#x201C;good&#x201D; as rated by all users with a mean of 4.2 on a 5-point Likert scale (primary performance endpoint). To further explore this result, we evaluated only those auscultations, that were rated &#x201C;good&#x201D; (score of 4) or &#x201C;very good&#x201D; (score of 5), as these ratings were considered most meaningful in terms of acoustic quality.</p>
<p>A total of 86.1% of all auscultations was rated &#x201C;good&#x201D; or &#x201C;very good&#x201D; across all users, and this value is in good agreement with the values of each user group (<xref rid="tab5" ref-type="table">Table 3</xref>).</p>
<p>These results are important for different reasons. First, they indicate a high level of satisfaction among all users with regard to the overall quality of auscultation sound transmission through the specific the SC material. Second, these findings indicate that the SC is capable of ensuring a high degree of auscultation accuracy in different body regions. This finding is of utmost clinical relevance as data on acoustic quality of commercially available stethoscope covers are scarce. Moreover, other technologies such as fully disposable single-use stethoscopes have been reported to come with substantial impairment of auscultation accuracy which may potentially lead to misdiagnoses and may therefore ultimately even impact patients&#x2019; safety (<xref ref-type="bibr" rid="ref17">17</xref>, <xref ref-type="bibr" rid="ref18">18</xref>).</p>
<p>When stratified for BMI, the ratings &#x201C;good&#x201D; or &#x201C;very good&#x201D; were recorded for 91.9% of auscultations in normal weight patients. As expected, the rating of the acoustic quality decreased with increasing BMI (85.1% in overweight patients, 85.3% in class I obese patients, and 62.5% in class III obese patients). This observation is not surprising, as with increasing body fat mass in thoracic or abdominal body areas, heart, lung or gastrointestinal tones would appear muted during normal auscultations. This observation is thus not attributable to the medical device.</p>
<p>When stratified for gender, the percentage of all auscultations rated as &#x201C;good&#x201D; and &#x201C;very good&#x201D; was 81.6% in females and 87.7% in males. Both values are in good agreement with the overall rating by all users (<xref rid="tab5" ref-type="table">Table 3</xref>). The slight difference between males and females might be rather due to their anatomical differences in the upper thoracic area, rather than device-related.</p>
<p>When stratified for auscultated body site the rating of the acoustic quality was stated as &#x201C;good&#x201D; and &#x201C;very good&#x201D; for 87.6, 89.2, and 84.2% of all auscultations of the heart, lung, and abdomen. These results are in good agreement with the overall rating by all users (<xref rid="tab5" ref-type="table">Table 3</xref>). Very few auscultations (<italic>N</italic>&#x2009;=&#x2009;10) were performed on &#x201C;Other&#x201D; body sites including carotid and femoral arteries and stomach. The percentage of auscultations rated as &#x201C;good&#x201D; or better was lower (40.0%) than for heart, lung, or abdomen. However, this finding is not unexpected and not considered to be attributable to the SC given the general challenge in auscultating these &#x201C;Other&#x201D; body sites and their generally low sound profile, especially if no pathological alterations have occurred.</p>
<p>In regard to the secondary performance endpoint, this study showed that the SC is easy to handle and may thus enable quick implementation into the clinical routine of HCPs. Handling of the product was rated for 96.4% of all auscultations to be&#x201D; reasonable,&#x201D; &#x201C;good&#x201D; or &#x201C;very good&#x201D; (score of 3, 4, or 5 on the 5-point Likert scale), highlighting the high degree of acceptance by the users and their general willingness to use the SC in their daily work.</p>
<p>The stratification analysis showed that despite some expected differences between males and females, body sites as well as among BMI classes, which do all apply to auscultations in general, the SC presented with an overall good performance profile throughout the study and for all patients independent from gender, BMI or auscultated body site. Even in highly obese patients, for which it is well known that auscultations can be truly challenging, the device performed in a satisfying manner based on the user ratings.</p>
</sec>
<sec id="sec25">
<title>The participating users quickly adopted the SC into their clinical routine</title>
<p>The high level of acceptance for the product observed in the present study is encouraging when considering the generally extremely low compliance of HCPs towards sufficient stethoscope hygiene or the general reluctance to adopt new technologies or procedures to improve it. Even though stethoscope cleanliness guidelines exist (<xref ref-type="bibr" rid="ref14">14</xref>), and despite tremendous educational efforts, this problem remains a key challenge. In fact, most of the approaches taken to enhance stethoscope hygiene have been ineffective and ultimately failed (<xref ref-type="bibr" rid="ref2">2</xref>, <xref ref-type="bibr" rid="ref12">12</xref>, <xref ref-type="bibr" rid="ref13">13</xref>). In a recent observational investigation, Boulee et al. evaluated physicians&#x2019; frequency and methods of stethoscope and hand hygiene practices. In only 18% of the 400 observed interactions, stethoscopes were cleaned at all, and when done, less than 4% complied with the CDC guidelines (<xref ref-type="bibr" rid="ref14">14</xref>). The authors concluded that stethoscope hygiene is largely neglected in daily clinical routine and they strongly urged that the compliance towards stethoscope cleanliness needs to be rapidly addressed (<xref ref-type="bibr" rid="ref12">12</xref>). To this end, Muniz and colleagues assessed the reasons for poor stethoscope hygiene compliance and anonymously surveyed nurses, nurse practitioners, and physicians at a large academic pediatric hospital. They found that perceived barriers for low stethoscope hygiene included lack of materials on hand, lack of time, and most importantly, lack of visual reminders (<xref ref-type="bibr" rid="ref13">13</xref>).</p>
<p>Another interesting observation from this study was the rapid learning curve of the SC application which substantially differs from other stethoscope single-cover concepts that usually target the sole coverage of the stethoscope diaphragm. The SC, however, covers the stethoscope bell including the users auscultating hand. After its use, it is easily pulled off the hand (which is still holding the stethoscope) and discarded. In fact, the SC concept is based on the same principles as other single-use protective equipment that is used in clinical routine (e.g., medical gloves). Notably, this may represent a conceptual advantage when compared to other commercially available standard microbiological stethoscope barriers as these require manual placement of the clean cover on a potentially contaminated stethoscope. These maneuvers carry a considerable risk for iatrogenic contamination of either the clean disc, the user&#x2019;s hand, or both. To the contrary, this risk could be minimized or even fully eliminated with the SC approach.</p>
<p>The high acceptance of the SC within the user groups in this study and rapid learning curve of the handling indicates that HCP may adapt this medical device in the daily clinical routine.</p>
</sec>
</sec>
<sec id="sec26">
<title>Limitations</title>
<p>This study has several limitations: Firstly, this was a single-center study in an ICU setting and user experiences with the product in other healthcare settings are not available yet.</p>
<p>However, this study was carried out in a high-demand ICU environment on early postoperative cardiac patients, i.e., a critical patient population. Therefore, although results cannot be generalized to other healthcare settings and patient populations, expansion of observations from this study to other health care areas is anticipated. Secondly, the evaluation of prevention of pathogen transmission was not assessed, and was beyond the scope of this study. Thirdly, to enable a real-life setting, no control group or randomization was added to the study protocol. In addition, auscultating the same patient with and without the SC even in a randomized manner would have caused a bias as the user would have known what to hear after the first auscultation event (whether with or without the SC cover).</p>
<p>Finally, it should also be recognized that the study was carried out on postoperative cardiac patients in a high demand ICU environment. For such freshly operated patients, it is well established that the proper auscultation can be challenging. They are often lying flat in their ICU beds, and usually still carry loads of fluids in their body (e.g., in the pleura or pericardium or abdominally) early after surgery, thus representing a &#x201C;worst case scenario&#x201D; population for auscultation.</p>
</sec>
<sec id="sec27" sec-type="conclusions">
<title>Conclusion</title>
<p>This study using a real-world healthcare environment of a cardiovascular ICU demonstrated that the SC can be safely used as a hygienic cover for stethoscopes during auscultations. Device acceptance was high across various HCP user groups, which may indicate its potential easily adoptable into clinical routine. The rating levels for the acoustic quality of auscultations performed with the SC were high across all user groups. Effects of gender, auscultation site and BMI on the acoustic quality of auscultations the SC were comparable to the effects on auscultations in general, but not attributable to the use or design of the product. Therefore, the SC may represent a safe, simple and useful tool to improve patient safety and to reduce the risk of stethoscope-mediated infections in the clinical routine workflow without impairing the acoustic quality of auscultations.</p>
</sec>
<sec id="sec28" sec-type="data-availability">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="sec29">
<title>Ethics statement</title>
<p>The studies involving human participants were reviewed and approved by 21-702-MP Mono-IVE17 and 94.1-03-5,660-13,526. The patients/participants provided their written informed consent to participate in this study.</p>
</sec>
<sec id="sec30">
<title>Author contributions</title>
<p>TN-S and ME designed and oversaw the clinical study and prepared the first draft of this manuscript. HM, VE, MS, FS, AF, and TN-S were responsible for patient recruitment and data management. Data analysis was performed by Heidi Kulas from the IGES Institute GmbH in Berlin. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="sec31" sec-type="funding-information">
<title>Funding</title>
<p>This work was supported by Stethoglove GmbH, Hamburg Germany. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.</p>
</sec>
<sec id="conf1" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>ME is a scientific advisor to Stethoglove GmbH. Outside the submitted work: VF has relevant (institutional) financial activities with following commercial entities: Medtronic GmbH, Biotronik SE &#x0026; Co., Abbott GmbH &#x0026; Co. KG, Boston Scientific, Edwards Lifesciences, Berlin Heart, Novartis Pharma GmbH, JOTEC GmbH and Zurich Heart in relation to educational Grants (including travel support), fees for lectures and speeches, fees for professional consultation and research and study funds.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="sec100" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
</body>
<back>
<ack>
<p>The authors of this manuscript would like to thank the nursing and physician staff of the intensive care unit at the German Heart Center Berlin for their active and voluntary participation in this study. TN-S is a scholar in the BIH Charit&#x00E9; Clinician Scientist Program funded by the Charit&#x00E9; &#x2013; Universit&#x00E1;tsmedizin Berlin and the Berlin Institute of Health.</p>
</ack>
<sec id="sec33" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary material for this article can be found online at: <ext-link xlink:href="https://www.frontiersin.org/articles/10.3389/fmed.2023.1179145/full#supplementary-material" ext-link-type="uri">https://www.frontiersin.org/articles/10.3389/fmed.2023.1179145/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Data_Sheet_1.docx" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haque</surname> <given-names>M</given-names></name> <name><surname>Sartelli</surname> <given-names>M</given-names></name> <name><surname>McKimm</surname> <given-names>J</given-names></name> <name><surname>Abu</surname> <given-names>BM</given-names></name></person-group>. <article-title>Health care-associated infections &#x2013; an overview</article-title>. <source>Infect Drug Resist</source>. (<year>2018</year>) <volume>11</volume>:<fpage>2321</fpage>&#x2013;<lpage>33</lpage>. doi: <pub-id pub-id-type="doi">10.2147/IDR.S177247</pub-id>, PMID: <pub-id pub-id-type="pmid">30532565</pub-id></citation>
</ref>
<ref id="ref2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Amin</surname> <given-names>A</given-names></name>
</person-group>. <article-title>Keeping the stethoscope, the Clinician&#x2019;s third hand</article-title>. <source>Clean Infection Control Today</source>. (<year>2021</year>) <volume>25</volume>:<fpage>26</fpage>&#x2013;<lpage>7</lpage>.</citation>
</ref>
<ref id="ref3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bernard</surname> <given-names>L</given-names></name> <name><surname>Kereveur</surname> <given-names>A</given-names></name> <name><surname>Durand</surname> <given-names>D</given-names></name> <name><surname>Gonot</surname> <given-names>J</given-names></name> <name><surname>Goldstein</surname> <given-names>F</given-names></name> <name><surname>Mainardi</surname> <given-names>JL</given-names></name> <etal/></person-group>. <article-title>Bacterial contamination of hospital physicians&#x2019; stethoscopes</article-title>. <source>Infect Control Hosp Epidemiol</source>. (<year>1999</year>) <volume>20</volume>:<fpage>626</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1086/501686</pub-id>, PMID: <pub-id pub-id-type="pmid">10501265</pub-id></citation>
</ref>
<ref id="ref4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Datta</surname> <given-names>P</given-names></name> <name><surname>Kaur</surname> <given-names>M</given-names></name> <name><surname>Rawat</surname> <given-names>S</given-names></name> <name><surname>Gupta</surname> <given-names>V</given-names></name> <name><surname>Chander</surname> <given-names>J</given-names></name></person-group>. <article-title>Stethoscope, &#x201C;the friendly foe&#x201D; &#x2013; a study to evaluate bacterial contamination of stethoscopes and disinfection practices</article-title>. <source>J Infect Dev Ctries</source>. (<year>2018</year>) <volume>12</volume>:<fpage>887</fpage>&#x2013;<lpage>93</lpage>. doi: <pub-id pub-id-type="doi">10.3855/jidc.10128</pub-id>, PMID: <pub-id pub-id-type="pmid">32004158</pub-id></citation>
</ref>
<ref id="ref5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jones</surname> <given-names>JS</given-names></name> <name><surname>Hoerle</surname> <given-names>D</given-names></name> <name><surname>Riekse</surname> <given-names>R</given-names></name></person-group>. <article-title>Stethoscopes: a potential vector of infection?</article-title> <source>Ann Emerg Med</source>. (<year>1995</year>) <volume>26</volume>:<fpage>296</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1016/S0196-0644(95)70075-7</pub-id>, PMID: <pub-id pub-id-type="pmid">7661417</pub-id></citation>
</ref>
<ref id="ref6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Longtin</surname> <given-names>Y</given-names></name> <name><surname>Schneider</surname> <given-names>A</given-names></name> <name><surname>Tschopp</surname> <given-names>C</given-names></name> <name><surname>Renzi</surname> <given-names>G</given-names></name> <name><surname>Gayet-Ageron</surname> <given-names>A</given-names></name> <name><surname>Schrenzel</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Contamination of stethoscopes and physicians&#x2019; hands after a physical examination</article-title>. <source>Mayo Clin Proc</source>. (<year>2014</year>) <volume>89</volume>:<fpage>291</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.mayocp.2013.11.016</pub-id>, PMID: <pub-id pub-id-type="pmid">24582188</pub-id></citation>
</ref>
<ref id="ref7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vasudevan</surname> <given-names>RS</given-names></name> <name><surname>Bin Thani</surname> <given-names>K</given-names></name> <name><surname>Aljawder</surname> <given-names>D</given-names></name> <name><surname>Maisel</surname> <given-names>S</given-names></name> <name><surname>Maisel</surname> <given-names>AS</given-names></name></person-group>. <article-title>The stethoscope: a potential vector for COVID-19?</article-title> <source>Eur Heart J</source>. (<year>2020</year>) <volume>41</volume>:<fpage>3393</fpage>&#x2013;<lpage>5</lpage>. doi: <pub-id pub-id-type="doi">10.1093/eurheartj/ehaa657</pub-id>, PMID: <pub-id pub-id-type="pmid">33045743</pub-id></citation>
</ref>
<ref id="ref8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>O&#x2019;Flaherty</surname> <given-names>N</given-names></name> <name><surname>Fenelon</surname> <given-names>L</given-names></name></person-group>. <article-title>The stethoscope and healthcare-associated infection: a snake in the grass or innocent bystander?</article-title> <source>J Hosp Infect</source>. (<year>2015</year>) <volume>91</volume>:<fpage>1</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jhin.2015.04.010</pub-id></citation>
</ref>
<ref id="ref9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bukharie</surname> <given-names>HA</given-names></name> <name><surname>Al-Zahrani</surname> <given-names>H</given-names></name> <name><surname>Rubaish</surname> <given-names>AM</given-names></name> <name><surname>Abdulmohsen</surname> <given-names>MF</given-names></name></person-group>. <article-title>Bacterial contamination of stethoscopes</article-title>. <source>J Family Community Med</source>. (<year>2004</year>) <volume>11</volume>:<fpage>31</fpage>&#x2013;<lpage>3</lpage>. PMID: <pub-id pub-id-type="pmid">23012043</pub-id></citation>
</ref>
<ref id="ref10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vasudevan</surname> <given-names>RS</given-names></name> <name><surname>Horiuchi</surname> <given-names>Y</given-names></name> <name><surname>Torriani</surname> <given-names>FJ</given-names></name> <name><surname>Cotter</surname> <given-names>B</given-names></name> <name><surname>Maisel</surname> <given-names>SM</given-names></name> <name><surname>Dadwal</surname> <given-names>SS</given-names></name> <etal/></person-group>. <article-title>Persistent value of the stethoscope in the age of COVID-19</article-title>. <source>Am J Med</source>. (<year>2020</year>) <volume>133</volume>:<fpage>1143</fpage>&#x2013;<lpage>50</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.amjmed.2020.05.018</pub-id>, PMID: <pub-id pub-id-type="pmid">32569591</pub-id></citation>
</ref>
<ref id="ref11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Napolitani</surname> <given-names>M</given-names></name> <name><surname>Bezzini</surname> <given-names>D</given-names></name> <name><surname>Moirano</surname> <given-names>F</given-names></name> <name><surname>Bedogni</surname> <given-names>C</given-names></name> <name><surname>Messina</surname> <given-names>G</given-names></name></person-group>. <article-title>Methods of disinfecting stethoscopes: systematic review</article-title>. <source>Int J Environ Res Public Health</source>. (<year>2020</year>) <volume>17</volume>:<fpage>17</fpage>. doi: <pub-id pub-id-type="doi">10.3390/ijerph17061856</pub-id></citation>
</ref>
<ref id="ref12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boulee</surname> <given-names>D</given-names></name> <name><surname>Kalra</surname> <given-names>S</given-names></name> <name><surname>Haddock</surname> <given-names>A</given-names></name> <name><surname>Johnson</surname> <given-names>TD</given-names></name> <name><surname>Peacock</surname> <given-names>WF</given-names></name></person-group>. <article-title>Contemporary stethoscope cleaning practices: what we haven&#x2019;t learned in 150 years</article-title>. <source>Am J Infect Control</source>. (<year>2019</year>) <volume>47</volume>:<fpage>238</fpage>&#x2013;<lpage>42</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ajic.2018.08.005</pub-id>, PMID: <pub-id pub-id-type="pmid">30396696</pub-id></citation>
</ref>
<ref id="ref13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Muniz</surname> <given-names>J</given-names></name> <name><surname>Sethi</surname> <given-names>RK</given-names></name> <name><surname>Zaghi</surname> <given-names>J</given-names></name> <name><surname>Ziniel</surname> <given-names>SI</given-names></name> <name><surname>Sandora</surname> <given-names>TJ</given-names></name></person-group>. <article-title>Predictors of stethoscope disinfection among pediatric health care providers</article-title>. <source>Am J Infect Control</source>. (<year>2012</year>) <volume>40</volume>:<fpage>922</fpage>&#x2013;<lpage>5</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ajic.2011.11.021</pub-id></citation>
</ref>
<ref id="ref14">
<label>14.</label>
<citation citation-type="other"><person-group person-group-type="author"><name><surname>Rutala</surname> <given-names>WA WD</given-names></name> <name><surname>Weinsten</surname> <given-names>RA</given-names></name></person-group>; The healthcare infection control practices advisory committee (HICPAC). Guideline for disinfection and sterilization in healthcare facilities, (<year>2008</year>). Available at: <ext-link xlink:href="https://www.cdc.gov/infectioncontrol/pdf/guidelines/disinfection-guidelines.pdf" ext-link-type="uri">https://www.cdc.gov/infectioncontrol/pdf/guidelines/disinfection-guidelines.pdf</ext-link>. (Accessed February 15, 2017)</citation>
</ref>
<ref id="ref15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Whittington</surname> <given-names>AM</given-names></name> <name><surname>Whitlow</surname> <given-names>G</given-names></name> <name><surname>Hewson</surname> <given-names>D</given-names></name> <name><surname>Thomas</surname> <given-names>C</given-names></name> <name><surname>Brett</surname> <given-names>SJ</given-names></name></person-group>. <article-title>Bacterial contamination of stethoscopes on the intensive care unit</article-title>. <source>Anaesthesia</source>. (<year>2009</year>) <volume>64</volume>:<fpage>620</fpage>&#x2013;<lpage>4</lpage>. doi: <pub-id pub-id-type="doi">10.1111/j.1365-2044.2009.05892.x</pub-id>, PMID: <pub-id pub-id-type="pmid">19453315</pub-id></citation>
</ref>
<ref id="ref16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vasudevan</surname> <given-names>R</given-names></name> <name><surname>Shin</surname> <given-names>JH</given-names></name> <name><surname>Chopyk</surname> <given-names>J</given-names></name> <name><surname>Peacock</surname> <given-names>WF</given-names></name> <name><surname>Torriani</surname> <given-names>FJ</given-names></name> <name><surname>Maisel</surname> <given-names>AS</given-names></name> <etal/></person-group>. <article-title>Aseptic barriers allow a clean contact for contaminated stethoscope diaphragms</article-title>. <source>Mayo Clin Proc Innov Qual Outcomes</source>. (<year>2020</year>) <volume>4</volume>:<fpage>21</fpage>&#x2013;<lpage>30</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.mayocpiqo.2019.10.010</pub-id>, PMID: <pub-id pub-id-type="pmid">32055768</pub-id></citation>
</ref>
<ref id="ref17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kalra</surname> <given-names>S</given-names></name> <name><surname>Garri</surname> <given-names>RF</given-names></name> <name><surname>Shewale</surname> <given-names>JB</given-names></name></person-group>. <article-title>Aseptic disposable stethoscope barrier: acoustically invisible and superior to disposable stethoscopes</article-title>. <source>Mayo Clin Proc</source>. (<year>2021</year>) <volume>96</volume>:<fpage>263</fpage>&#x2013;<lpage>4</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.mayocp.2020.10.029</pub-id>, PMID: <pub-id pub-id-type="pmid">33413829</pub-id></citation>
</ref>
<ref id="ref18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mehmood</surname> <given-names>M</given-names></name> <name><surname>Abu Grara</surname> <given-names>HL</given-names></name> <name><surname>Stewart</surname> <given-names>JS</given-names></name> <name><surname>Khasawneh</surname> <given-names>FA</given-names></name></person-group>. <article-title>Comparing the auscultatory accuracy of health care professionals using three different brands of stethoscopes on a simulator</article-title>. <source>Med Devices</source>. (<year>2014</year>) <volume>7</volume>:<fpage>273</fpage>&#x2013;<lpage>81</lpage>. doi: <pub-id pub-id-type="doi">10.2147/MDER.S67784</pub-id>, PMID: <pub-id pub-id-type="pmid">25152636</pub-id></citation>
</ref>
</ref-list>
<glossary>
<def-list>
<title>Abbreviations</title>
<def-item>
<term>BMI</term>
<def>
<p>Body-Mass-Index</p>
</def>
</def-item>
<def-item>
<term>HCI</term>
<def>
<p>Healthcare-associated infection</p>
</def>
</def-item>
<def-item>
<term>HCP</term>
<def>
<p>Healthcare professional</p>
</def>
</def-item>
<def-item>
<term>ICU</term>
<def>
<p>Intensive care unit</p>
</def>
</def-item>
<def-item>
<term>TPU</term>
<def>
<p>Thermoplastic urethane</p>
</def>
</def-item>
</def-list>
</glossary>
</back>
</article>