Abstract
Objective:
The accurate prediction of peri-implant disease severity is crucial for timely intervention and successful long-term outcomes. This study aimed to develop and validate an interpretable machine learning model that evaluates whether multi-dimensional prosthodontic configurations alone, without relying on direct inflammatory indicators, can assist in classifying the cross-sectional severity of peri-implant diseases.
Methods:
A retrospective analysis was conducted on 300 implants from 285 patients. Data encompassed patient demographics, implant characteristics, and prosthodontic features, including Margin Fit (MF), Screw Access Space (SAS), prosthesis type, prosthesis material, and implant position. To prevent label leakage and tautological reasoning, direct diagnostic criteria (Probing Depth and Bleeding Index) were strictly excluded from the predictor matrix. The dataset was partitioned at the patient level into an internal training set (n = 200 patients; 210 implants) and an internal hold-out validation set (n = 85 patients; 90 implants). Four machine learning algorithms (Ordinal Logistic Regression, SVM, Random Forest, and XGBoost) were developed and validated. Model performance was evaluated using accuracy, F1-score, and AUC. Model interpretability was assessed using SHapley Additive exPlanations (SHAP), and clinical utility was determined via Decision Curve Analysis (DCA). A nomogram was also constructed.
Results:
The XGBoost model achieved the highest discriminative performance on the internal validation set, with an overall accuracy of 78.9% and a macro-averaged AUC of 0.821 (95% CI: 0.760–0.882). SHAP analysis identified Margin Fit, Screw Access Space, and prosthesis material as the most influential features associated with disease stage classification. Decision Curve Analysis (DCA) demonstrated a positive clinical net benefit across decision threshold probabilities from 15% to 65%. The multivariable ordinal logistic regression model yielded a diagnostic AUC of 0.774, confirming the additional discriminative gain provided by non-linear ML ensembles.
Conclusion:
A non-linear machine learning framework incorporating prosthodontic features—free of label-leaking clinical indices—can objectively aid in classifying peri-implant disease stages in a cross-sectional setting. This tool should be framed as an automated diagnostic aid rather than a longitudinal prognostic system, pending multi-center external validation.
1 Introduction
The successful long-term maintenance of dental implants is challenged by biological complications, primarily peri-implant mucositis and peri-implantitis (). Peri-implantitis, characterized by progressive bone loss, can ultimately lead to implant failure, posing significant clinical and financial burdens for patients (). The prevalence of peri-implant diseases is substantial, with reported rates varying widely but often exceeding 40% for mucositis and 20% for peri-implantitis (). Early detection and accurate classification of disease severity are therefore paramount to implement appropriate preventive or therapeutic measures and prevent irreversible damage ().
Current diagnosis relies on a combination of clinical examinations, such as probing depth measurement and bleeding on probing, and radiographic assessment of bone levels (). While these methods are the clinical standard, they have limitations. Clinical parameters can be subjective and may not fully capture the underlying disease activity until significant tissue destruction has occurred. Furthermore, the assessment often focuses on existing inflammation rather than predicting its future severity or identifying at-risk sites proactively (). There is a growing recognition that the risk of peri-implant disease is multifactorial, involving not only patient-related factors but also iatrogenic and biomechanical variables associated with the implant-supported restoration.
Prosthodontic factors, such as the precision of the restoration margin fit and the design of the prosthetic components, are theoretically critical for maintaining peri-implant health (). Poor marginal adaptation can create a niche for bacterial colonization, while inadequate screw access space may complicate maintenance and lead to screw loosening (). However, these detailed prosthodontic parameters are often evaluated qualitatively or are not systematically integrated into a comprehensive risk assessment model in routine practice. This represents a missed opportunity to leverage readily available data for a more nuanced and personalized prediction of disease outcomes.
The advent of machine learning (ML) offers a powerful paradigm shift in medical and dental diagnostics. ML algorithms can process large, multi-dimensional datasets to identify complex, non-linear patterns and interactions among variables that may be imperceptible to human observers or traditional statistical models (, ). Several studies have explored ML for detecting periodontal disease or differentiating healthy from diseased implant sites (). However, few have focused on the more clinically relevant task of predicting the specific severity of peri-implant disease by incorporating a rich set of prosthodontic features alongside standard clinical signs.
Therefore, this study was designed to address this gap. Our primary objective was to develop and rigorously validate an ML-based model capable of predicting the severity of peri-implant disease (Healthy, Mucositis, Peri-implantitis) using a comprehensive array of multi-dimensional features from implant crown and bridge restorations. We further aimed to enhance the model's interpretability using state-of-the-art techniques (SHAP) and to translate the findings into a user-friendly clinical tool (nomogram), ultimately assessing its potential clinical utility through Decision Curve Analysis.
2 Materials and methods
2.1 Study design and population
This study was designed as a retrospective, cross-sectional analysis. The study protocol was reviewed and approved by the Institutional Review Board of the Second Hospital of Hebei Medical University, and the need for individual informed consent was waived due to the retrospective nature of the data collection.
Patients who received dental implant therapy the Second Hospital of Hebei Medical University between June 2022 and July 2024 were screened for inclusion. The inclusion criteria were: (1) patients aged ≥18 years; (2) presence of a single implant-supported crown or a fixed dental prosthesis (FDP) with up to three units, which had been in function for at least one year; and (3) availability of complete clinical and radiographic records. The exclusion criteria were: (1) history of systemic diseases that could affect peri-implant conditions (e.g., uncontrolled diabetes, immunosuppressive therapy); (2) current pregnancy or lactation; (3) a history of radiotherapy in the head and neck region; and (4) incomplete or illegible patient records.
2.2 Data collection and variable definition
A single calibrated examiner, blinded to the study's objectives, extracted all data from the patients' digital records. The collected data encompassed three dimensions:
Patient Demographics: Age and gender.
Implant and Prosthesis Characteristics: Implant position (maxilla/mandible), prosthesis type (single crown/FDP), and prosthesis material [Zirconia, Porcelain-Fused-to-Metal (PFM), or Lithium Disilicate (Emax)].
Clinical and Radiographic Features:
Ground Truth Diagnostic Labeling: The primary outcome variable was classified according to consensus criteria into three mutually exclusive categories: Healthy (PD ≤ 4 mm, no bleeding on probing), Mucositis (PD ≤ 4 mm with bleeding on probing), and Peri-implantitis (PD ≥ 5 mm with bleeding on probing and accompanying radiographic bone loss).
Input Predictor Matrix (Anti-Leakage Protocol): Crucially, because PD and BI formed the deterministic diagnostic rules for ground truth labeling, both PD and BI were strictly excluded from the candidate predictor matrix to prevent tautological circularity and data leakage. The final predictor set was composed exclusively of independent prosthodontic, anatomical, and demographic variables: Margin Fit (MF, μm), Screw Access Space (SAS, mm), prosthesis type (single crown vs. FDP), prosthesis material (Zirconia, PFM, or Emax), implant position (maxilla vs. mandible), and patient age.
2.3 Data partitioning and preprocessing
To eliminate intra-subject dependency and prevent optimistic performance bias, data splitting was strictly executed at the patient level rather than the implant level using grouped stratified sampling (grouped by patient ID). The 300 implants from 285 patients were split 70:30 into an internal training set (200 patients; 210 implants) and an internal hold-out validation set (85 patients; 90 implants), ensuring that multiple implants from the same individual were assigned to the same subset without cross-partition overlap.
For categorical variables (e.g., gender, prosthesis material), one-hot encoding was applied to convert them into a numerical format suitable for machine learning algorithms. All continuous features were standardized using Z-score normalization (subtracting the mean and dividing by the standard deviation) based on the statistics of the training set. This preprocessing step was performed to prevent features with larger scales from dominating the model training process. The same transformation parameters were applied to the test set to avoid data leakage.
2.4 Feature selection
To identify the most relevant predictors and reduce dimensionality, a two-step feature selection process was employed on the training set. First, features with a variance close to zero were removed. Second, the importance of the remaining features was ranked using a Random Forest classifier. The top 15 features with the highest Mean Decrease in Gini importance were selected for subsequent model development.
2.5 Model development
Four distinct machine learning algorithms were implemented to develop predictive models for peri-implant disease severity:
Multivariable Ordinal Logistic Regression (OLR): Given that the target outcome comprises three ordered disease stages (Healthy < Mucositis < Peri-implantitis), an ordinal logistic regression (proportional odds model) was implemented using the polr function from the MASS package in R (v4.2.1). The proportional odds assumption across cut-offs was evaluated using the Brant test (brant package in R). Cumulative odds ratios (Adjusted ORs) with corresponding 95% confidence intervals (CIs) were estimated to quantify the association between prosthodontic features and escalating disease severity.
Support Vector Machine (SVM): A powerful classifier that finds an optimal hyperplane to separate classes in a high-dimensional space, using a radial basis function (RBF) kernel.
Random Forest (RF): An ensemble learning method that operates by constructing a multitude of decision trees during training and outputting the class that is the mode of the classes of the individual trees.
Extreme Gradient Boosting (XGBoost): A scalable and highly efficient gradient boosting framework that has proven effective in numerous classification tasks.
All models were trained exclusively on the training set. To handle hyperparameter optimization and prevent overfitting, a 5-fold cross-validation combined with a grid search strategy was used for SVM, RF, and XGBoost. The model with the highest macro-averaged F1-score during cross-validation was selected as the final model for each algorithm.
2.6 Model evaluation
The performance of all trained models was evaluated on the independent test set, which was not used during any phase of model training or tuning. The following metrics were used:
Overall Accuracy: The proportion of correctly classified cases.
Precision, Recall, and F1-Score: Calculated for each class individually and then averaged (macro-average) to evaluate the model's performance on imbalanced data.
Confusion Matrix: To visualize the model's classification performance in detail.
Area Under the Receiver Operating Characteristic Curve (AUC): To assess the discriminative ability of the models for each class in a one-vs.-rest manner.
Brier Score and Calibration Plot: To evaluate the calibration of the probabilistic predictions.
2.7 Model interpretability
To enhance the transparency and trustworthiness of the best-performing model (XGBoost), SHAP (SHapley Additive exPlanations) was employed. SHAP values were calculated to explain the model's predictions at both the global and local levels. Global interpretability was visualized using a SHAP summary plot to show the overall impact and direction of each feature. Local interpretability was demonstrated using a SHAP force plot to explain the prediction for an individual case.
2.8 Decision curve analysis
The clinical net benefit of using the predictive model was assessed using Decision Curve Analysis (DCA). This technique evaluates the clinical consequences of decision-making across a range of threshold probabilities, comparing the net benefit of using the model against the strategies of treating all patients or treating none.
2.9 Statistical analysis
All statistical analyses and machine learning modeling were performed using R software (version 4.2.1, R Foundation for Statistical Computing, Vienna, Austria). The R packages used included caret for data partitioning and model training, randomForest and xgboost for model implementation, pROC for ROC analysis, shapviz for SHAP interpretation, rmda for decision curve analysis, and ggplot2 for data visualization. For the comparison of baseline characteristics, a two-sided t-test was used for continuous variables, and the Chi-squared test or Fisher's exact test was used for categorical variables. A p-value of less than 0.05 was considered statistically significant.
2.10. Model calibration and clinical tool development
In addition to discrimination assessed by the AUC, the calibration of the model's probabilistic predictions was formally evaluated. A calibration plot was constructed by grouping the test set into deciles based on their predicted risk and plotting the observed event rate against the mean predicted probability for each decile. The Hosmer–Lemeshow chi-squared test was also performed to quantify the goodness-of-fit between predicted and observed outcomes.
To facilitate clinical translation, a multivariable logistic regression model was developed using the independent predictors identified in the multivariate analysis. This model was then used to construct a nomogram, which provides a visual, point-based tool for estimating an individual patient's risk of peri-implantitis without the need for a computer.
2.11. Sample size justification
The sample size was evaluated based on the Events Per Variable (EPV) criterion. In the overall cohort, the least frequent category (Peri-implantitis) comprised 100 events (70 in the training set). Following the deliberate omission of leaking clinical indices (PD and BI), the final model utilized 5 independent predictor dimensions (Margin Fit, Screw Access Space, prosthesis material, prosthesis type, and implant position/age). This yielded an effective EPV of 70/5 = 14.0 in the training set, comfortably satisfying the classical threshold of ≥10 EPV for multivariable model stability. Furthermore, 5-fold cross-validation with tree regularization (shrinkage η = 0.05, max depth = 3) was implemented to prevent model overfitting.
3 Results
3.1 Baseline characteristics of the study cohort
A total of 300 implants from 285 patients were systematically partitioned into training (n = 210) and test (n = 90) sets (Figure 1A). As detailed in Table 1, the two cohorts exhibited a high degree of equilibrium across all baseline variables, including age, gender, and implant position (all p > 0.05). The disease severity was uniformly distributed in the test set (Figure 1B). Density estimation for Margin Fit revealed progressive anatomical separation across the stages (Figure 1C). Initial benchmarking of four algorithms identified XGBoost as the most promising model (Figure 1D), achieving a superior macro-averaged ROC-AUC of 0.82 (Figure 1E). Spearman correlation analysis highlighted significant inter-variable dependencies (Figure 1F).
Figure 1
Table 1
| Variables | Overall cohort (N = 300) | Training set (n = 210) | Internal validation set (n = 90) | P-value |
|---|---|---|---|---|
| Demographics | ||||
| Age (years, mean ± SD) | 55.2 ± 10.5 | 55.5 ± 10.8 | 54.5 ± 9.8 | 0.421 |
| Gender (male/female, n) | 145/155 | 102/108 | 43/47 | 0.853 |
| Implant characteristics | ||||
| Position: maxilla/mandible (%) | 162 (54.0)/138 (46.0) | 113 (53.8)/97 (46.2) | 49 (54.4)/41 (45.6) | 0.902 |
| Prosthodontic predictor features | ||||
| Prosthesis type: single crown/FDP (%) | 198 (66.0)/102 (34.0) | 139 (66.2)/71 (33.8) | 59 (65.6)/31 (34.4) | 0.915 |
| Prosthesis material (Zirconia/PFM/Emax) | 140/110/50 | 98/77/35 | 42/33/15 | 0.992 |
| Margin fit vertical discrepancy (μm, mean ± SD) | 48.5 ± 35.2 | 49.1 ± 35.8 | 47.1 ± 33.9 | 0.642 |
| Screw access space (mm, mean ± SD) | 0.52 ± 0.21 | 0.53 ± 0.22 | 0.51 ± 0.20 | 0.485 |
| Diagnostic gold-standard reference markersa | ||||
| Probing depth (mm, mean ± SD) | 4.02 ± 1.82 | 4.05 ± 1.85 | 3.95 ± 1.76 | 0.593 |
| Bleeding index (0–3, mean ± SD) | 1.45 ± 0.92 | 1.48 ± 0.93 | 1.38 ± 0.89 | 0.295 |
| Disease classification (healthy/mucositis/peri-implantitis) | 100/100/100 | 70/70/70 | 30/30/30 | 1.000 |
Baseline characteristics of the study population in training and test sets.
Probing depth and bleeding index were used solely for clinical ground-truth categorization and were strictly omitted from all predictive models to avoid label leakage.
3.2 Quantitative distribution of multi-dimensional features
The quantitative distribution profiles of prosthodontic parameters across the three diagnostic categories are depicted in Figure 2. Vertical Margin Fit discrepancies exhibited a marked stepwise elevation from Healthy and Peri-implantitis (p < 0.001) (Figure 2A and Table 2). Concurrently, available Screw Access Space demonstrated significant progressive constriction across advancing disease severity (Figure 2B). Evaluation of restoration materials revealed that PFM crowns accounted for 55.0% of all peri-implantitis cases, whereas Zirconia restorations predominated in the healthy cohort (62.0%) (Figure 2C). Multi-unit FDP restorations similarly showed greater representation in the peri-implantitis group (51.0%) compared to single units (18.0%) (Figure 2D). Pairwise correlation confirmed an inverse relationship between Margin Fit vertical gaps and Screw Access dimensions (p < 0.001) (Figure 2E). These multi-dimensional prosthodontic variations (Figure 2F) establish the distinct restorative phenotypes underpinning the subsequent machine learning feature space.
Figure 2
Table 2
| Candidate feature | Unadjusted OR | 95% Confidence interval (CI) | P-value |
|---|---|---|---|
| Margin fit (per 10 μm increase) | 1.35 | 1.21–1.52 | <0.001 |
| Screw access space (per 0.1 mm decrease) | 1.42 | 1.15–1.76 | 0.001 |
| Prosthesis material (reference: zirconia) | |||
| PFM (porcelain-fused-to-metal) | 1.84 | 1.18–2.86 | 0.007 |
| Emax (lithium disilicate) | 1.12 | 0.61–2.05 | 0.718 |
| Prosthesis type (reference: single crown) | |||
| Fixed dental prosthesis (FDP) | 1.48 | 0.96–2.28 | 0.076 |
| Implant position (reference: mandible) | |||
| Maxilla | 1.08 | 0.72–1.62 | 0.712 |
| Age (per 10-year increase) | 1.11 | 0.92–1.34 | 0.278 |
Univariate ordinal logistic regression of candidate prosthodontic features associated with peri-implant disease classification.
3.3 Global and local model interpretability
SHAP analysis provided transparent mechanistic insight into the unbiased prosthodontic XGBoost model (Figure 3). Global importance ranking (Figure 3A) and the summary beeswarm plot (Figure 3B) confirmed that Margin Fit (MF), Screw Access Space (SAS), and Prosthesis Material were the top drivers associated with peri-implant disease classification. Dependence plots revealed that the classification weight for Margin Fit accelerated non-linearly once vertical discrepancy surpassed \approx 45\ \mu\text{m} (Figure 3C). Furthermore, a distinct non-linear interaction was captured between Margin Fit and Screw Access Space, demonstrating that the adverse impact of marginal microgaps was markedly amplified when screw access space was constricted below 0.4 mm (Figure 3D). Local case explanations illustrated that small marginal discrepancies (−0.62 SHAP) strongly supported healthy classifications (Figure 3E), whereas severe vertical misfit (+0.85 SHAP) pushed classification decisively toward peri-implantitis (Figure 3F).
Figure 3
3.4 Rigorous model performance evaluation
The unbiased prosthodontic XGBoost model demonstrated robust discriminative ability on the internal hold-out validation set. Multi-class ROC analysis yielded AUCs of 0.84, 0.77, and 0.85 for Healthy, Mucositis, and Peri-implantitis, respectively, yielding an overall macro-averaged AUC of 0.821 (95% CI: 0.760–0.882) (Figure 4A). The PR curve demonstrated stable precision across clinical recall thresholds (Figure 4B). The confusion matrix showed an overall accuracy of 78.9% (71/90 implants correctly staged) (Figure 4C), with misclassifications occurring predominantly between adjacent stages (Table 3). Calibration analysis indicated that predicted probabilities matched observed frequencies reasonably well (Figure 4D). In head-to-head benchmarking, XGBoost consistently outperformed Ordinal Logistic Regression (Accuracy: 70.0%, AUC: 0.774), SVM (Accuracy: 72.2%, AUC: 0.765), and Random Forest (Accuracy: 75.6%, AUC: 0.798) (Figure 4E), maintaining superior per-class F1-scores across categories (Figure 4F).
Figure 4
Table 3
| Disease category | Precision | Recall (sensitivity) | F1-score | AUC (95% CI) |
|---|---|---|---|---|
| Healthy | 0.833 | 0.833 | 0.833 | 0.842 (0.751–0.933) |
| Mucositis | 0.724 | 0.700 | 0.712 | 0.771 (0.665–0.877) |
| Peri-implantitis | 0.806 | 0.833 | 0.820 | 0.850 (0.763–0.937) |
| Macro average | 0.788 | 0.789 | 0.788 | 0.821 (0.760–0.882) |
| Overall accuracy | 78.9% (71/90) |
Multi-class performance metrics of the final XGBoost model on the internal hold-out validation set (n = 90).
3.5 Clinical nomogram and utility assessment
Multivariate ordinal logistic regression identified Margin Fit, Screw Access Space, and prosthesis material as independent contributors (Table 4), which were integrated into a visual prosthodontic nomogram (Figure 5A). The nomogram's calibration was confirmed through a goodness-of-fit curve (Figure 5B). Decision Curve Analysis (DCA) demonstrated a superior net benefit for the model across clinical threshold probabilities from 15% to 65% (Figure 5C). The clinical impact curve (Figure 5D) and nomogram scoring weights (Figure 5E) further illustrated its translational value. Risk stratification using the prosthetic score effectively separated implants into high-risk (73.3% actual disease incidence), intermediate-risk (46.7%), and low-risk (16.7%) groups (Figure 5F).
Table 4
| Independent feature | Adjusted odds ratio (aOR) | 95% Confidence interval (CI) | P-value |
|---|---|---|---|
| Margin fit (per 10 μm increase) | 1.31 | 1.16–1.48 | <0.001 |
| Screw access space (per 0.1 mm decrease) | 1.38 | 1.10–1.73 | 0.005 |
| Prosthesis material (reference: zirconia) | |||
| PFM | 1.68 | 1.05–2.69 | 0.031 |
| Emax | 1.05 | 0.56–1.96 | 0.879 |
| Prosthesis type (reference: single crown) | |||
| Fixed dental prosthesis (FDP) | 1.25 | 0.78–2.01 | 0.354 |
Multivariable ordinal logistic regression analysis of independent prosthodontic features.
Figure 5
3.6 Robustness analysis across clinical subgroups
To verify the stability and transportability of the unbiased prosthodontic model, comprehensive subgroup benchmarking was performed (Figure 6). Forest plot analysis confirmed consistent discriminative AUCs across restoration materials, jaw locations, and prosthetic designs, ranging from 0.78 to 0.85 (Figure 6A). Radar charts demonstrated that diagnostic metrics remained stable between younger (<55 years) and older (≥55 years) individuals without age-related bias (Figure 6B). Residual error distributions for single crowns and multi-unit FDPs were symmetrically centered around zero (Figure 6C). Subgroup calibration across Zirconia and PFM cohorts exhibited good concordance with empirical disease rates (Figure 6D), alongside stable sensitivity-specificity profiles (Figure 6E). Finally, feature importance evaluation across restoration materials confirmed that Margin Fit and Screw Access Space consistently occupied the primary ranks regardless of material composition (Figure 6F).
Figure 6
3.7 Implementation workflow and consistency
To facilitate translational integration, a clinical implementation pipeline was structured (Figure 7). The risk probability heatmap illustrates the compounding effect between vertical marginal gaps and restricted screw access space (Figure 7A). Subgroup forest plots confirmed stable discriminative performance across anatomical positions and restorative materials, with AUCs consistently maintaining between 0.78 and 0.85 (Figure 7B). The standardized workflow guides practitioners through prosthodontic data input, automated ML inference, and tiered decision support (Figure 7C). Agreement analysis between the AI model and senior clinical specialists showed an acceptable correlation of r = 0.76 (Figure 7D, Table 5). Based on the calculated prosthetic hazard tiers, personalized maintenance recall schedules were formulated to monitor high-risk sites proactively (Figure 7E), with visual scoring points directly convertible for chairside use (Figure 7F).
Figure 7
Table 5
| Comparison pair | Cohen’s quadratic weighted κ | Overall diagnostic agreement (%) | Kendall’s tau-b (τb) |
|---|---|---|---|
| AI model vs. senior specialist 1 | 0.762 | 78.9% | 0.725 |
| AI model vs. senior specialist 2 | 0.748 | 77.8% | 0.710 |
| Specialist 1 vs. specialist 2 | 0.841 | 85.6% | 0.804 |
Inter-rater and diagnostic consistency between the prosthodontic AI model and clinical diagnosis on the validation cohort (n = 90).
3.8 Comprehensive impact and diagnostic gain
Advanced metrics and human-machine comparisons were used to assess practical value (Figure 8). PR analysis demonstrated robust average precision for peri-implantitis identification (Figure 8A). Learning curves confirmed that the model reached a performance plateau around 200 samples, indicating adequate training sample size (Figure 8B). In comparative benchmarking, AI-assisted evaluation significantly improved diagnostic staging consistency compared to clinicians alone (p < 0.001, Figure 8C). Finally, the model-driven intervention was projected to optimize clinical management in 90% of all cases, facilitating earlier diagnosis and optimized treatment planning (Figure 8D).
Figure 8
4 Discussion
In this study, we successfully developed and validated a machine learning model incorporating multi-dimensional prosthodontic and clinical features to predict the severity of peri-implant diseases. The XGBoost model demonstrated excellent performance, with high accuracy, AUC, and well-calibrated probabilities, outperforming both other machine learning algorithms and a traditional multivariate logistic regression model. Through SHAP analysis, we enhanced the model's interpretability, and the development of a nomogram and DCA confirmed its potential clinical utility. Our findings underscore the power of integrating detailed prosthodontic parameters with standard clinical indicators to achieve a more precise and automated assessment of peri-implant health.
While clinical parameters like Probing Depth and Bleeding Index are universally recognized as the cornerstone for establishing a diagnosis (), their inclusion in predictive algorithms introduces circular reasoning. By deliberately excluding them from the input matrix, our results highlight the significant and independent contribution of purely prosthodontic configurations. The significant association between vertical Margin Fit discrepancies and advancing disease stages, along with its ranking as the top predictor in our non-linear model, provides quantitative evidence supporting the clinical observation that restoration microgaps represent critical mechanical correlates of peri-implant pathology. This aligns with the findings of Jafer et al. and others who have emphasized the biological impact of microgaps and cement excess (–). Similarly, Screw Access Space emerged as a novel but relevant predictor, likely reflecting the ease of cleaning and the potential for microbial colonization in the prosthetic components (–). By moving beyond purely clinical signs, our model captures the iatrogenic and biomechanical aspects of implant therapy, leading to a more holistic risk assessment. Importantly, given the retrospective, cross-sectional design of this study, the observed relationships between prosthodontic features (such as Margin Fit discrepancies and constricted Screw Access Space) and disease classifications must be interpreted strictly as statistical associations rather than proven causal mechanisms. Although microgaps are known to harbor bacterial plaque, longitudinal prospective studies monitoring pristine restorations from baseline are essential to definitively establish temporal causation.
The superior performance of the XGBoost model over traditional logistic regression is noteworthy (). The univariate and multivariate analyses confirmed the linear relationships of the main risk factors, which were well-represented in the nomogram (). However, XGBoost's higher accuracy suggests its ability to capture complex, non-linear interactions among features that are not accounted for in standard regression models. For instance, the SHAP interaction plot revealed that the adverse effect of Margin Fit discrepancies was markedly amplified in the presence of a constricted Screw Access Space (<0.4 mm), a nuanced non-linear biomechanical interaction that standard additive linear models fail to capture (–). This capability to learn from data without pre-specified interaction terms is a key advantage of machine learning in complex clinical scenarios.
A critical aspect of any predictive model is its interpretability and trustworthiness, which are essential for clinical adoption (, ). Our use of SHAP values addressed this problem. The SHAP summary plot provided an intuitive, global view of the model's logic, reinforcing the predominant biomechanical impact of Margin Fit and Screw Access Space while quantifying the relative contributions of restorative materials (, ). The local force plot offered a transparent explanation for an individual prediction, which could be a powerful tool for patient-clinician communication. This level of transparency is a significant step forward from opaque models and is increasingly demanded by both clinicians and regulatory bodies (–).
To bridge the gap between the complex algorithm and point-of-care use, we developed a simple nomogram. While its performance was slightly lower than the full XGBoost model, its ease of use makes it a valuable tool for initial screening, especially in settings without advanced software. Furthermore, the Decision Curve Analysis provided compelling evidence for the model's clinical net benefit, showing that it could guide decision-making more effectively than standard “treat-all” or “treat-none” approaches across a wide range of clinical thresholds.
This study has several important methodological limitations. First, we explicitly emphasize that the evaluation conducted herein represents an internal hold-out validation rather than a true external validation, even though strict patient-level separation was maintained to avoid intra-subject bias. Because data were collected from a single medical center, subtle institutional biases in implant placement and prosthetic workflows cannot be excluded, and multi-center prospective studies using external validation cohorts are required before claiming broad generalizability. Second, regarding sample size and dimensionality, while the revised feature set (5 predictors) yielded an improved EPV of approximately 14.0 for the peri-implantitis category and cross-validation learning curves showed minimal divergence, mild risk of model overfitting cannot be entirely ruled out in tree-based architectures. Third, while we included detailed prosthodontic features, several critical patient-level systemic modifiers (e.g., precise plaque index, smoking habits, and glycemic control) were unavailable in retrospective charts. Finally, 2D periapical radiographs were used to assess Margin Fit and Screw Access Space, which may provide less comprehensive spatial resolution than 3D cone-beam computed tomography (CBCT).
Future research should focus on external validation of this model in multi-center studies to test its transportability and robustness. Prospective trials are needed to assess its real-world impact on clinical outcomes, such as early detection leading to improved treatment success rates. Incorporating additional patient-level risk factors and leveraging more advanced imaging data could further enhance the model's predictive power. Ultimately, the integration of such a model into clinical decision-support software could revolutionize the management of peri-implant health, enabling a shift from a reactive to a proactive, personalized, and precision-based approach to care.
5 Conclusion
In conclusion, this study demonstrates that a machine learning model, particularly XGBoost, can accurately predict the severity of peri-implant diseases by integrating both standard clinical measurements and detailed prosthodontic features. Key contributing features include Margin Fit vertical discrepancy, Screw Access Space, and restorative material. The model's high performance, combined with its interpretability via SHAP and its demonstrated clinical utility through DCA and a user-friendly nomogram, positions it as a promising tool for enhancing the precision of peri-implant disease diagnosis and management.
Statements
Data availability statement
The datasets presented in this article are not readily available because the dataset contains sensitive clinical records and multi-dimensional longitudinal parameters of individual patients, including dental implant characteristics, exact clinical probing measurements, and radiographic evaluations. According to the strict data protection policies of the Institutional Review Board of the Second Hospital of Hebei Medical University and national medical privacy regulations, public dissemination of this raw repository is prohibited to prevent any potential re-identification or breach of patient confidentiality. Consequently, data sharing is restricted to non-commercial, academic verification purposes only, and will be made available upon reasonable request following secondary ethical vetting. Requests to access the datasets should be directed to Name: Guanjun Zhou 28111741@hebmu.edu.cn.
Ethics statement
The study protocol was reviewed and approved by the Institutional Review Board of the Second Hospital of Hebei Medical University, and the need for individual informed consent was waived due to the retrospective nature of the data collection. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants' legal guardians/next of kin because the study was a retrospective, cross-sectional analysis utilizing historical digital medical records. The requirement for written informed consent was formally waived by the Institutional Review Board of the Second Hospital of Hebei Medical University because all patient data were fully anonymized and de-identified prior to analysis, ensuring zero risk to patient privacy and no impact on clinical decisions.
Author contributions
GL: Data curation, Formal analysis, Investigation, Software, Writing – original draft. NX: Project administration, Writing – original draft. ZD: Project administration, Supervision, Writing – original draft. GZ: Funding acquisition, Resources, Writing – review & editing.
Funding
The author(s) declared that financial support was not received for this work and/or its publication.
Acknowledgments
We thank all individuals who contributed to the data collection and clinical coordination of this research.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Abbreviations
AUC, area under the curve; BI, bleeding index; CI, confidence interval; DCA, decision curve analysis; FDP, fixed dental prosthesis; MF, margin fit; ML, machine learning; OR, odds ratio; PD, probing depth; PFM, porcelain-fused-to-metal; RF, random forest; SAS, screw access space; SHAP, SHapley Additive exPlanations; SVM, support vector machine; XGBoost, extreme gradient boosting.
References
1.
SalemDMKwonTHAlshihriALevinL. Long-term preservation and maintenance of periodontally compromised teeth: a narrative literature review, recommended approach, and case series. Quintessence Int. (2025) 56:178–85. 10.3290/j.qi.b6046543
2.
BanjarAA. Retrograde peri-implantitis: a scoping review of current understanding of a rare complication in dental implants. J Oral Implantol. (2025) 51:376–83. 10.1563/aaid-joi-D-24-00226
3.
AtiehMAShahMHakamAAidATawse-SmithAAlsabeehaNHM. Peri-implantitis and survival outcomes of tissue level versus bone level dental implants: a systematic review and meta-analysis. Clin Exp Dent Res. (2025) 11:e70242. 10.1002/cre2.70242
4.
UrbanIAChenZWangHL. Decision tree for reconstructive treatment of peri-implantitis defects. Int J Periodontics Restorative Dent. (2025) 45:439–49. 10.11607/prd.7205
5.
ReisIHuamán-MendozaAARamadanDHonórioHMNaenniNRomitoGAet al. The prevalence of peri-implant mucositis and peri-implantitis based on the world workshop criteria: a systematic review and meta-analysis. J Dent. (2025) 160:105914. 10.1016/j.jdent.2025.105914
6.
KibcakEBuharaOTemelciAAkkayaNÜnsalGMinerviniG. Deep learning-driven segmentation of dental implants and peri-implantitis detection in orthopantomographs: a novel diagnostic tool. J Evid Based Dent Pract. (2025) 25:102058. 10.1016/j.jebdp.2024.102058
7.
RoyRChopraAKarmakarSBhatSG. Applications of artificial intelligence (AI) for diagnosis of periodontal/peri-implant diseases: a narrative review. J Oral Rehabil. (2025) 52:1193–219. 10.1111/joor.14045
8.
DungSZWangJWengTHTuYK. Long-term outcomes and risk assessment of immediate implants at molar extraction sites in a Taiwan population. Sci Rep. (2025) 15:23333. 10.1038/s41598-025-06048-z
9.
ZhangYMaMHuangXLiuJTianCDuanZet al. Machine learning is changing osteoporosis detection: an integrative review. Osteoporos Int. (2025) 36:1313–26. 10.1007/s00198-025-07541-x
10.
HuangSXuQYangGDingJPeiQ. Machine learning for prediction of drug concentrations: application and challenges. Clin Pharmacol Ther. (2025) 117:1236–47. 10.1002/cpt.3577
11.
KoidouVPChatzopoulosGSTsalikisLKaklamanosEG. Large language models in peri-implant disease: how well do they perform?J Prosthet Dent. (2025) 134:2435–42. 10.1016/j.prosdent.2025.02.008
12.
MadaniZFakharHB. Detection and classification of peri-implant marginal bone loss in cone-beam computed tomography using a deep learning approach. Clin Exp Dent Res. (2026) 12:e70308. 10.1002/cre2.70308
13.
JaferMAQadiriAAMtwamNAHakamiAHMowklyAABhandiSet al. Influence of human and bacterial enzymes on resin restorations: a review. J Contemp Dent Pract. (2022) 23:371–7. 10.5005/jp-journals-10024-3250
14.
YangFDuYZhangZWangMYinWZhouZet al. Evaluation of microgaps and microleakage at the implant-abutment interface of individualized abutments in the maxillary anterior region under functional loading: a pragmatic clinical trial. J Prosthodont Res. (2025) 69:58–67. 10.2186/jpr.JPR_D_23_00317
15.
DurraniFNahidRPandeySSinghPPandeyA. One-piece implants: careful approach for complex rehabilitation. Natl J Maxillofac Surg. (2021) 12:266–70. 10.4103/njms.NJMS_191_20
16.
YuHSunMWangZ. Clinical decision-making of anterior implant abutment. Hua Xi Kou Qiang Yi Xue Za Zhi. (2022) 40:504–12. 10.7518/hxkq.2022.05.002
17.
McLaughlinSDMillerNRSabolJV. Restoration of a nonideally placed anterior implant: a clinical report. J Prosthet Dent. (2023) 129:523–6. 10.1016/j.prosdent.2021.06.040
18.
AngelaraKBratosMSorensenJA. Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J Prosthet Dent. (2023) 129:221–7. 10.1016/j.prosdent.2021.04.025
19.
LiangDWangLZhongPLinJChenLChenQet al. Perspective: global burden of iodine deficiency: insights and projections to 2050 using XGBoost and SHAP. Adv Nutr. (2025) 16:100384. 10.1016/j.advnut.2025.100384
20.
CarliGMelesSKReesinkFEDe JongBMPilottoAPadovaniAet al. Comparison of univariate and multivariate analyses for brain [18F]FDG PET data in α-synucleinopathies. Neuroimage Clin. (2023) 39:103475. 10.1016/j.nicl.2023.103475
21.
HanYWangS. Disability risk prediction model based on machine learning among Chinese healthy older adults: results from the China health and retirement longitudinal study. Front Public Health. (2023) 11:1271595. 10.3389/fpubh.2023.1271595
22.
LiWHuangGTangNLuPJiangLLvJet al. Effects of heavy metal exposure on hypertension: a machine learning modeling approach. Chemosphere. (2023) 337:139435. 10.1016/j.chemosphere.2023.139435
23.
ZhangBChenLLiT. Unveiling the effect of urinary xenoestrogens on chronic kidney disease in adults: a machine learning model. Ecotoxicol Environ Saf. (2025) 292:117945. 10.1016/j.ecoenv.2025.117945
24.
ZhouQHuangRXiongXLiangZZhangW. Prediction of pulmonary embolism by an explainable machine learning approach in the real world. Sci Rep. (2025) 15:835. 10.1038/s41598-024-75435-9
25.
ShenLJinYPanAWangKYeRLinYet al. Machine learning-based predictive models for perioperative major adverse cardiovascular events in patients with stable coronary artery disease undergoing noncardiac surgery. Comput Methods Programs Biomed. (2025) 260:108561. 10.1016/j.cmpb.2024.108561
26.
RamtekeMRautS. Prediction of polycystic ovary syndrome using machine learning with SFS and boruta feature selection: an explainable AI approach. Syst Biol Reprod Med. (2025) 71:439–60. 10.1080/19396368.2025.2560839
27.
YangRXiongXWangHLiW. Explainable machine learning model to prediction EGFR mutation in lung cancer. Front Oncol. (2022) 12:924144. 10.3389/fonc.2022.924144
28.
FanZJiangJXiaoCChenYXiaQWangJet al. Construction and validation of prognostic models in critically ill patients with sepsis-associated acute kidney injury: interpretable machine learning approach. J Transl Med. (2023) 21:406. 10.1186/s12967-023-04205-4
29.
PaiKCSuSAChanMCWuCLChaoWC. Explainable machine learning approach to predict extubation in critically ill ventilated patients: a retrospective study in central Taiwan. BMC Anesthesiol. (2022) 22:351. 10.1186/s12871-022-01888-y
30.
XianTMehandjievNConstantinidesPChenYWQuboaQKitchenG. Clinician preferences for explainable AI in critical care: a comparative study of interpretable models and visualizations for intubation decision support. Int J Med Inform. (2026) 210:106287. 10.1016/j.ijmedinf.2026.106287
Summary
Keywords
dental implant, machine learning, peri-implantitis, prosthodontics, risk prediction
Citation
Li G, Xu N, Duan Z and Zhou G (2026) Integrating multi-dimensional prosthodontic features into an interpretable XGBoost framework for cross-sectional diagnostic classification of peri-implant diseases. Front. Med. 13:1883041. doi: 10.3389/fmed.2026.1883041
Received
16 May 2026
Revised
30 September 2026
Accepted
05 October 2026
Published
28 October 2026
Volume
13 - 2026
Edited by
Saurabh Chaturvedi, King Khalid University, Saudi Arabia
Reviewed by
Vinay Sivaswamy, Ajman University, United Arab Emirates
Nancy Jidiya, Faculty of Dental Science, India
Updates
Copyright
© 2026 Li, Xu, Duan and Zhou.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Guanjun Zhou 28111741@hebmu.edu.cn
† These authors have contributed equally to this work and share first authorship
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.