<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oncol.</journal-id>
<journal-title>Frontiers in Oncology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oncol.</abbrev-journal-title>
<issn pub-type="epub">2234-943X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fonc.2023.1165664</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Oncology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Direct attenuation correction for <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT lung cancer images using deep learning</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Xing</surname>
<given-names>Haiqun</given-names>
</name>
<uri xlink:href="https://loop.frontiersin.org/people/2207539"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Tong</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Jin</surname>
<given-names>Xiaona</given-names>
</name>
<uri xlink:href="https://loop.frontiersin.org/people/1505950"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tian</surname>
<given-names>Jian</given-names>
</name>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ba</surname>
<given-names>Jiantao</given-names>
</name>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Jing</surname>
<given-names>Hongli</given-names>
</name>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Li</surname>
<given-names>Fang</given-names>
</name>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<institution>Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine</institution>, <addr-line>Beijing</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>Edited by: Andrea Ciarmiello, Sapienza University of Rome, Italy</p>
</fn>
<fn fn-type="edited-by">
<p>Reviewed by: Jia Huang, Shanghai Jiao Tong University, China; Guozhu Hou, Chinese Academy of Medical Sciences and Peking Union Medical College, China; Jingjing Zhang, National University of Singapore, Singapore</p>
</fn>
<fn fn-type="corresp" id="fn001">
<p>*Correspondence: Jiantao Ba, <email xlink:href="mailto:bajiantao@189.cn">bajiantao@189.cn</email>; Hongli Jing, <email xlink:href="mailto:annsmile1976@sina.com">annsmile1976@sina.com</email>; Fang Li, <email xlink:href="mailto:lifang@pumch.cn">lifang@pumch.cn</email>
</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>12</day>
<month>05</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>13</volume>
<elocation-id>1165664</elocation-id>
<history>
<date date-type="received">
<day>14</day>
<month>02</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>26</day>
<month>04</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Xing, Wang, Jin, Tian, Ba, Jing and Li</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Xing, Wang, Jin, Tian, Ba, Jing and Li</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<sec>
<title>Introduction</title>
<p>The attenuation correction technique of single photon emission computed tomography (SPECT) images is essential for early diagnosis, therapeutic evaluation, and pharmacokinetic studies of lung cancer. <sup>99m</sup>Tc-3PRGD<sub>2</sub> is a novel radiotracer for the early diagnosis and evaluation of treatment effects of lung cancer. This study preliminary discusses the deep learning method to directly correct the attenuation of <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images.</p>
</sec>
<sec>
<title>Methods</title>
<p>Retrospective analysis was performed on 53 patients with pathological diagnosis of lung cancer who received <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT/CT. All patients&#x2019; SPECT/CT images were reconstructed with CT attenuation correction (CT-AC) and without attenuation correction (NAC). The CT-AC image was used as the reference standard (Ground Truth) to train the attenuation correction (DL-AC) SPECT image model using deep learning. A total of 48 of 53 cases were divided randomly into the training set, the remaining 5 were divided into the testing set. Using 3D Unet neural network, the mean square error loss function (MSELoss) of 0.0001 was selected. A testing set is used to evaluate the model quality, using the SPECT image quality evaluation and quantitative analysis of lung lesions tumor-to-background (T/B).</p>
</sec>
<sec>
<title>Results</title>
<p>SPECT imaging quality metrics between DL-AC and CT-AC including mean absolute error (MAE), mean-square error (MSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), normalized root mean square error (NRMSE), and normalized Mutual Information (NMI) of the testing set are 2.62 &#xb1; 0.45, 58.5 &#xb1; 14.85, 45.67 &#xb1; 2.80, 0.82 &#xb1; 0.02, 0.07 &#xb1; 0.04, and 1.58 &#xb1; 0.06, respectively. These results indicate PSNR &gt; 42, SSIM &gt; 0.8, and NRMSE &lt; 0.11. Lung lesions T/B (maximum) of CT-AC and DL-AC groups are 4.36 &#xb1; 3.52 and 4.33 &#xb1; 3.09, respectively (p = 0.81). There are no significant differences between two attenuation correction methods.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Our preliminary research results indicate that using the DL-AC method to directly correct <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images is highly accurate and feasible for SPECT without configuration with CT or treatment effect evaluation using multiple SPECT/CT scans.</p>
</sec>
</abstract>
<kwd-group>
<kwd>
<sup>99m</sup>Tc-3PRGD2</kwd>
<kwd>Chest SPECT</kwd>
<kwd>CT-attenuation correction</kwd>
<kwd>deep learning attenuation correction</kwd>
<kwd>lung cancer</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="13"/>
<page-count count="6"/>
<word-count count="2865"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-in-acceptance</meta-name>
<meta-value>Cancer Imaging and Image-directed Interventions</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<title>Introduction</title>
<p>Lung cancer is one of the most commonly diagnosed cancers and the leading cause of cancer-related deaths worldwide with an estimated two million new cases each year. The incidence and mortality of lung cancer in China accounted for 37.0% and 39.8% of the world&#x2019;s total, respectively, ranking first in cancer incidence and mortality (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>). Non-small cell lung cancer (NSCLC) accounts for almost 85% of lung cancer (<xref ref-type="bibr" rid="B3">3</xref>). Early diagnosis and accurate staging are essential to improve the survival rate of lung cancer patients. With the deepening of the research on the molecular pathological mechanism of lung cancer, new biomarkers have been discovered and used for clinical diagnosis and targeted therapy. Molecular imaging can non-invasively detect dynamic molecular processes <italic>in vivo</italic>, offering enormous potential for early diagnosis, accurate staging, and guidance for treatment. Accordingly, molecular imaging agents would be highly useful in the non-invasive detection of lung cancer.</p>
<p>The arginine&#x2013;glycine&#x2013;aspartic acid (RGD) tripeptide sequence can specifically bind to the integrin &#x3b1;<sub>V</sub>&#x3b2;<sub>3</sub> receptors, which is highly expressed on tumor cells and activated endothelial cells. <sup>99m</sup>Tc-PEG<sub>4</sub>-E[PEG<sub>4</sub>-c(RGDfK)]<sub>2</sub> (<sup>99m</sup>Tc-3PRGD<sub>2</sub>) is a novel RGD containing single photon emission computed tomography (SPECT) radiotracer targeting integrin &#x3b1;<sub>V</sub>&#x3b2;<sub>3</sub> receptors for tumor detection, angiogenesis imaging, and tumor therapy efficacy assessment. Preliminary results from multicenter studies indicate that <sup>99m</sup>Tc-3PRGD<sub>2</sub> imaging is sensitive for the detection of lung malignancies (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>). Attenuation correction of <sup>99m</sup>Tc-3PRGD<sub>2</sub> SPECT chest tomography images is the basis of accurate quantification. To date, some SPECT devices have been configured with the co-location CT, commonly known as SPECT/CT, to perform attenuation correction of SPECT images. However, there are still some SPECT devices that are not configured with CT, and the adopted off-machine CT attenuation correction or uniform image attenuation correction is subject to large errors. Even for patients using SPECT/CT for treatment monitoring, it is not necessary to use CT scan images for attenuation correction of SPECT in every SPECT/CT scan to reduce the CT radiation dose of patients. SPECT attenuation correction has received attention in clinical practice.</p>
<p>The deep learning method has been used to directly perform attenuation correction studies on PET and SPECT images, and satisfactory results have been obtained for attenuation correction of myocardial perfusion SPECT images (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>). This can improve the attenuation correction accuracy of the SPECT/CT images and provide a new accurate and efficient attenuation correction method for SPECT without CT. At present, there are no studies involving deep-learning-based attenuation correction studies of <sup>99m</sup>Tc-3PRGD<sub>2</sub> for chest SPECT images. In this study, the deep-learning-based attenuation correction method for <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images of lung cancer patients is discussed.</p>
</sec>
<sec id="s2" sec-type="materials|methods">
<title>Materials and methods</title>
<p>This retrospective study was approved by the ethics committee of Chinese Academy of Medical Sciences and Peking Union Medical College Hospital. From 2012 to 2017, 53 patients with pathological diagnoses of lung cancer were collected from <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images using the Precedence SPECT/CT system (Philips, Netherlands). Written informed consent was obtained from each patient. All patients underwent <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT/CT. The 53 patients included 26 women and 27 men, aged 38&#x2013;72 years (mean age &#xb1; SD, 60.40 &#xb1; 7.21 years old). The maximum diameter of lung lesions ranged from 1.60 to 106.60&#xa0;mm (mean &#xb1; SD, 39.94 &#xb1; 20.25&#xa0;mm). Chest SPECT scans were acquired 1&#xa0;h after intravenous injection of <sup>99m</sup>Tc-3PRGD<sub>2</sub> at a dose of 11.1 MBq/kg. SPECT scan parameters were as follows: low-energy high-resolution collimators and energy window of 140 keV &#xb1; 7.5%, 360&#xb0; scan, 64 projections, per projection of 30 s, zoom of 1.0, matrix of 128 &#xd7; 128, and pixel of 4.664&#xa0;mm. A low-dose chest scan CT was used to correct the attenuation of SPECT images. CT parameters were as follows: 120 kVp/30 mAs, matrix of 512 &#xd7; 512, pixel of 0.68&#xa0;mm, and thickness of 3.0&#xa0;mm. After scanning, the SPECT projection data and the CT reconstruction image were transferred to the image processing workstation. SPECT attenuation correction images (CT attenuation correction, CT-AC) and the images without attenuation correction (non-attenuation correction, NAC) were obtained throughout the image processing.</p>
<p>A total of 53 cases with <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images (CT-AC and NAC) were divided into a training set (n = 48; maximum lung lesions diameter, 39.98 &#xb1; 20.94&#xa0;mm) and a testing set (n = 5; maximum lung lesions diameter, 39.52 &#xb1; 13.39&#xa0;mm). CT-AC SPECT images were used as the reference standard (Ground Truth) to compare SPECT images with deep learning attenuation correction (DL-AC).</p>
<sec id="s2_1">
<title>Training set and testing set images</title>
<p>Through the MONAI deep learning framework, the depth of neural network using 3D Unet is shown in <xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>. The training set was pre-processed by uniformly adjusting the image size to (128, 128, 128). The data augmentation was done by randomly rotating 90&#xb0;. The parameters of the 3D Unet network in this study are as follows:</p>
<list list-type="bullet">
<list-item>
<p>The number of network input channels is 1; that is, the input is a 3D grayscale map.</p>
</list-item>
<list-item>
<p>The number of network output channels is also 1, and the output image size is (128, 128, 128).</p>
</list-item>
<list-item>
<p>After each convolution operation in the network encoder part, the number of output channels is successively (16, 32, 64, 128, 256), and the stride is 2.</p>
</list-item>
<list-item>
<p>The number of residual units is 3.</p>
</list-item>
<list-item>
<p>The normalization method is batch normalization.</p>
</list-item>
</list>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>3D Unet framework used for build modeling. The 3D grayscale image is used as input, and the output image size is (128, 128, 128).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1165664-g001.tif"/>
</fig>
<p>The mean square error loss function (MSELoss) was selected as 0.0001 in this study. Five testing sets were used to evaluate the trained DL-AC model.</p>
</sec>
<sec id="s2_2">
<title>Image quality evaluation and statistical analysis of data</title>
<p>The DL-AC effect was analyzed using both measurements of the <sup>99m</sup> Tc-3PRGD<sub>2</sub> whole SPECT chest images and local lesion method.</p>
<list list-type="simple">
<list-item>
<p>1) The error and similarity metrics between the SPECT attenuation correction with CT-AC and DL-AC are to be calculated. The evaluation indexes used by referring to the reported methods (<xref ref-type="bibr" rid="B8">8</xref>) include mean absolute error (MAE), mean square error (MSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), normalized root mean square error (NRMSE), and normalized mutual information (NMI). The error was expressed as mean &#xb1; SD.</p>
</list-item>
<list-item>
<p>2) T/B ratios of pulmonary lesions under SPECT CT-AC and DL-AC were measured. The tumor region of interest (ROI) was drawn by a preset threshold of 42% and was adjusted minimally according to visual assessment. Then, a mirror ROI was set over the contralateral normal lung as a control (<xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2</bold>
</xref>). The T/B ratios were calculated by (maximum and mean counts of the tumor ROI)/(maximum and mean counts of the control ROI). In cases where more than one lesion was detected in the lung, the lesion with the highest uptake was used for analysis. The T/B ratios were expressed as mean &#xb1; SD.</p>
</list-item>
</list>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Outline of lung lesion and background. Tumor indicate lung lesions that are drawn with a preset threshold of 42%. The background is a mirror ROI set over the contralateral normal lung as a control.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1165664-g002.tif"/>
</fig>
<p>All the statistical analysis in this study were performed using R 3.5.1 and Python 3.5.6.&#xa0;A self-paired <italic>t-</italic>test was used to compare the T/B ratios obtained from the same patients. p &lt; 0.05 indicated statistical significance.</p>
</sec>
</sec>
<sec id="s3" sec-type="results">
<title>Results</title>
<p>
<xref ref-type="table" rid="T1">
<bold>Table&#xa0;1</bold>
</xref> shows that five testing set SPECT imaging quality metrics between DL-AC and CT-AC including mean absolute error (MAE), mean square error (MSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), normalized root mean square error (NRMSE), and normalized mutual information (NMI) is 2.62 &#xb1; 0.45, 58.5 &#xb1; 14.85, 45.67 &#xb1; 2.80, 0.82 &#xb1; 0.02, 0.07 &#xb1; 0.04, and 1.58 &#xb1; 0.06, respectively. These results indicate that MAE &lt; 3.50, MSE &lt; 65.00, PSNR &gt; 42.00, SSIM &gt; 0.80, NRMSE &lt; 0.11, and NMI &gt; 1.60 (mean &#xb1; SD). <xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref> illustrates <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images of the same patient based on NAC, DL-AC, and DL-AC. The top row is SPECT axial image (NAC, CT-AC, and DL-AC), and the bottom row is SPECT coronal image (NAC, CT-AC, and DL-AC). It shows that DL-AC significantly improved the contrast of the chest image, and the SPECT images of DL-AC is close to those of CT-AC. <xref ref-type="fig" rid="f4">
<bold>Figure&#xa0;4</bold>
</xref> shows the error between CT-AC and DL-AC in SPECT axial image of another patient. In <xref ref-type="fig" rid="f4">
<bold>Figure&#xa0;4</bold>
</xref>, green indicates that the error is 0, and red indicates that the error is maximum. The error between the two correction methods (DL-AC and CT-AC) at the lesion site is very small. Outside the chest lesion, the error is close to 0 (green).</p>
<table-wrap id="T1" position="float">
<label>Table&#xa0;1</label>
<caption>
<p>Five testing set SPECT imaging quality metrics between DL-AC and CT-AC.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="center">case</th>
<th valign="middle" align="center">MAE<sup>*</sup>
</th>
<th valign="middle" align="center">MSE<sup>*</sup>
</th>
<th valign="middle" align="center">PSNR<sup>*</sup>
</th>
<th valign="middle" align="center">SSIM<sup>*</sup>
</th>
<th valign="middle" align="center">NRSME<sup>*</sup>
</th>
<th valign="middle" align="center">NMI<sup>*</sup>
</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="middle" align="center">1</td>
<td valign="middle" align="center">2.55</td>
<td valign="middle" align="center">63.74</td>
<td valign="middle" align="center">49.11</td>
<td valign="middle" align="center">0.81</td>
<td valign="middle" align="center">0.06</td>
<td valign="middle" align="center">1.63</td>
</tr>
<tr>
<td valign="middle" align="center">2</td>
<td valign="middle" align="center">1.88</td>
<td valign="middle" align="center">34.54</td>
<td valign="middle" align="center">47.51</td>
<td valign="middle" align="center">0.84</td>
<td valign="middle" align="center">0.07</td>
<td valign="middle" align="center">1.64</td>
</tr>
<tr>
<td valign="middle" align="center">3</td>
<td valign="middle" align="center">3.06</td>
<td valign="middle" align="center">75.15</td>
<td valign="middle" align="center">45.99</td>
<td valign="middle" align="center">0.83</td>
<td valign="middle" align="center">0.01</td>
<td valign="middle" align="center">1.58</td>
</tr>
<tr>
<td valign="middle" align="center">4</td>
<td valign="middle" align="center">2.76</td>
<td valign="middle" align="center">60.20</td>
<td valign="middle" align="center">43.26</td>
<td valign="middle" align="center">0.84</td>
<td valign="middle" align="center">0.08</td>
<td valign="middle" align="center">1.54</td>
</tr>
<tr>
<td valign="middle" align="center">5</td>
<td valign="middle" align="center">2.85</td>
<td valign="middle" align="center">58.89</td>
<td valign="middle" align="center">42.49</td>
<td valign="middle" align="center">0.80</td>
<td valign="middle" align="center">0.09</td>
<td valign="middle" align="center">1.50</td>
</tr>
<tr>
<td valign="middle" align="center">Mean &#xb1; SD</td>
<td valign="middle" align="center">2.62 &#xb1; 0.45</td>
<td valign="middle" align="center">58.50 &#xb1; 14.85</td>
<td valign="middle" align="center">45.67 &#xb1; 2.80</td>
<td valign="middle" align="center">0.82 &#xb1; 0.02</td>
<td valign="middle" align="center">0.07 &#xb1; 0.04</td>
<td valign="middle" align="center">1.58 &#xb1; 0.06</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>*MAE, mean absolute error; MSE, mean-square error; PSNR, Peak signal-to-noise ratio; SSIM, structural similarity; NRMSE, normalized root mean square error; NMI, normalized mutual information</p>
</fn>
</table-wrap-foot>
</table-wrap>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>
<sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images of the same patient based on NAC, CT-AC, and DL-AC. The top row are SPECT axial images (NAC, CT-AC, and DL-AC), and the bottom row are SPECT coronal images (NAC, CT-AC, and DL-AC). It can be seen that DL-AC significantly improves the contrast of the chest image, and the corrected image is close to the CT-AC image. On the axial image, the maximum diameter of the patient&#x2019;s lung lesion was 49.98&#xa0;mm, and the maximum T/B of the lesion on NAC, CT-AC, and DL-AC were 2.91, 3.80, and 3.78, respectively.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1165664-g003.tif"/>
</fig>
<fig id="f4" position="float">
<label>Figure&#xa0;4</label>
<caption>
<p>The error image between CT-AC and DL-AC in the SPECT axial image of another patient. The green color indicates that the error is 0, and the red color indicates that the error is maximum.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1165664-g004.tif"/>
</fig>
<p>In order to analyze the differences between the two methods more precisely, a quantitative analysis was performed. The <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT lesion T/B in both SPECT CT-AC and DL-AC is shown in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref>, which shows that the lesions T/B (maximum) between CT-AC and DL-AC in the training and testing sets were almost the same (3.78 &#xb1; 2.07 vs. 3.79 &#xb1; 2.07; 4.36 &#xb1; 3.52 vs. 4.33 &#xb1; 3.09, p &gt; 0.5), with no difference. The T/B (mean) between DL-AC and CT-AC in the training and testing sets is also not significantly different (3.41 &#xb1; 2.07 vs. 3.36 &#xb1; 1.77; 2.73 &#xb1; 1.36 vs. 2.86 &#xb1; 1.48, p &gt; 0.5). The axial image in <xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref> shows that the maximum diameter of the patient&#x2019;s lung lesion is 49.98&#xa0;mm, and the maximum T/B of the lesion on NAC, CT-AC, and DL-AC are 2.91, 3.80, and 3.78, respectively. DL-AC obtained lesion T/B close to CT-AC.</p>
<table-wrap id="T2" position="float">
<label>Table&#xa0;2</label>
<caption>
<p>Comparison of T/B between CT-AC and DL-AC on chest SPECT in 53 patients.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="center">Variable</th>
<th valign="top" align="center">CT-AC</th>
<th valign="top" align="center">DL-AC</th>
<th valign="top" align="center">Statistics</th>
<th valign="top" align="center">P-value</th>
</tr>
</thead>
<tbody>
<tr>
<th valign="top" colspan="5" align="left">Training set (n = 48)</th>
</tr>
<tr>
<td valign="top" align="left">T/B maximum</td>
<td valign="top" align="center">3.78 &#xb1; 2.07</td>
<td valign="top" align="center">3.79 &#xb1; 2.07</td>
<td valign="top" align="center">-0.017</td>
<td valign="top" align="center">0.987</td>
</tr>
<tr>
<td valign="top" align="left">T/B mean</td>
<td valign="top" align="center">3.41 &#xb1; 2.07</td>
<td valign="top" align="center">3.36 &#xb1; 1.77</td>
<td valign="top" align="center">0.625</td>
<td valign="top" align="center">0.534</td>
</tr>
<tr>
<th valign="top" colspan="5" align="left">Testing set (n = 5)</th>
</tr>
<tr>
<td valign="top" align="left">T/B maximum</td>
<td valign="top" align="center">4.36 &#xb1; 3.52</td>
<td valign="top" align="center">4.33 &#xb1; 3.09</td>
<td valign="top" align="center">0.015</td>
<td valign="top" align="center">0.988</td>
</tr>
<tr>
<td valign="top" align="left">T/B mean</td>
<td valign="top" align="center">2.73 &#xb1; 1.36</td>
<td valign="top" align="center">2.86 &#xb1; 1.48</td>
<td valign="top" align="center">-0.252</td>
<td valign="top" align="center">0.807</td>
</tr>
<tr>
<th valign="top" colspan="5" align="left">Total data set (n = 53)</th>
</tr>
<tr>
<td valign="top" align="left">T/B maximum</td>
<td valign="top" align="center">3.84 &#xb1; 2.20</td>
<td valign="top" align="center">3.84 &#xb1; 2.15</td>
<td valign="top" align="center">0.000</td>
<td valign="top" align="center">0.994</td>
</tr>
<tr>
<td valign="top" align="left">T/B mean</td>
<td valign="top" align="center">3.34 &#xb1; 2.02</td>
<td valign="top" align="center">3.40 &#xb1; 1.73</td>
<td valign="top" align="center">0.551</td>
<td valign="top" align="center">0.583</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>* T/B, tumor-to-background; CT-AC, CT-attenuation correction; DL-AC, deep learning-attenuation correction.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s4" sec-type="discussion">
<title>Discussion</title>
<p>Attenuation correction is particularly important for accurate quantitative analysis of SPECT images (<xref ref-type="bibr" rid="B9">9</xref>&#x2013;<xref ref-type="bibr" rid="B11">11</xref>), which are the basis for quantitative disease analysis, therapeutic efficacy evaluation, and pharmacokinetic studies. From the early uniformity attenuation correction to CT-AC and then to the latest deep learning-based methods, attenuation correction has significantly improved the image quality and accuracy of SPECT. This study shows that in the testing set of <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images, the imaging quality metrics between DL-AC and CT-AC indicates that PSNR &gt; 42, SSIM &gt; 0.8, and NRMSE &lt; 0.11. Lung lesions T/B in the training and testing sets do not differ between CT-AC and DL-AC (p &gt; 0.5). Overall, it is superior to the reported results (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>).</p>
<p>Using deep learning to correct the attenuation in chest images of lung cancer patients can significantly improve the image quality. The absolute error is &lt;4, the similarity is &gt;0.80, and PSNR is &gt;42. In comparison with the study of Yang et&#xa0;al. on cardiac DL-AC, the present study was superior to the results of Yang et&#xa0;al. on NRMSE (0.07 &#xb1; 0.04 vs. 0.148 &#xb1; 0.095) and PSNR (45.67 &#xb1; 2.80 vs. 36.20 &#xb1; 4.10), but slightly lower on SSIM (0.82 &#xb1; 0.02 vs. 0. 993 &#xb1; 0.006). The PSNR is significantly higher than that of Yang and other reported studies, which may be due to the high uptake of <sup>99m</sup>Tc-3PRGD<sub>2</sub> targeting drug lesions and low uptake of non-target tissues. Due to the different radiopharmaceuticals used in the two studies, there are significant differences in the distribution of the drugs in the chest and heart. SSIM is relatively low, this may be due to the fact that the study of Yang et&#xa0;al. on DL-AC selected the small-field cardiac images as the dataset, whereas the chest anatomy in this study was more complex, and the image field was larger. These results indicate that the DL-AC method can meet clinical needs and can be used as a method to correct the <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT attenuation in lung cancer patients.</p>
<p>This study is employed based on MONAI, 3D Unet framework because MONAI is a deep learning platform built for medical imaging. For the choice of neural network, the Unet framework in 3D rather than 2D was used in this study. This is mainly due to the fact that the chest SPECT image is a 3D structure after reconstruction, and the 2D approach tends to lead to interlayer errors (<xref ref-type="bibr" rid="B12">12</xref>). Torkaman et&#xa0;al. used Conditional Generative Adversarial Networks (CGAN) corrected for myocardial attenuation, and the preliminary results showed no significant advantage (<xref ref-type="bibr" rid="B13">13</xref>). This study provides a new method for accurate attenuation correction of SPECT devices not equipped with co-location CT and has clinical practical application value.</p>
<p>There are also some limitations in this study. The DL-AC model was established for Philips equipment, and the model of Siemens and GE equipment is also needed in the future. In addition, the current model group data set is small, which needs to be increased.</p>
</sec>
<sec id="s5" sec-type="conclusion">
<title>Conclusion</title>
<p>Our preliminary research results indicate that using DL-AC method to directly correct <sup>99m</sup>Tc-3PRGD<sub>2</sub> chest SPECT images is highly accurate and feasible for SPECT without configuration with CT or treatment effect evaluation using multiple SPECT/CT scans.</p>
</sec>
<sec id="s6" sec-type="data-availability">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s7" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>The studies involving human participants were reviewed and approved by the ethics committee of Chinese Academy of Medical Sciences and Peking Union Medical College Hospital. The patients/participants provided their written informed consent to participate in this study.</p>
</sec>
<sec id="s8" sec-type="author-contributions">
<title>Author contributions</title>
<p>All authors contributed to conception and design of the study. HX, TW, XJ, and JT completed data collection, data processing, and analysis. XJ and JT completed illustration preparation, and HX and TW completed thesis writing. JB, HJ, and FL guided the research design, data verification, and paper revision. All authors contributed to the article and approved the submitted version.</p>
</sec>
</body>
<back>
<sec id="s9" sec-type="funding-information">
<title>Funding</title>
<p>This work was supported by CAMS Innovation Fund for Medical Sciences (No. CIFMS 2021-I2M-1-002) and the National High Level Hospital Clinical Research Funding (No. 2022-PUMCH-C-003).</p>
</sec>
<sec id="s10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The reviewer GH declared a shared affiliation with the authors to the handling editor at the time of review.</p>
</sec>
<sec id="s11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sun</surname> <given-names>H</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>G</given-names>
</name>
<name>
<surname>Lu</surname> <given-names>H</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>X</given-names>
</name>
</person-group>. <article-title>Research progress of 99mtc-3prgd2 Spect/Ct in staging and efficacy evaluation of lung tumors</article-title>. <source>J Mol Imaging</source> (<year>2021</year>) <volume>44</volume>(<issue>5</issue>):<page-range>868&#x2013;72</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.12122/j.issn.1674-4500.2021.05.27</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Thai</surname> <given-names>A</given-names>
</name>
<name>
<surname>Solomon</surname> <given-names>B</given-names>
</name>
<name>
<surname>Sequist</surname> <given-names>L</given-names>
</name>
<name>
<surname>Gainor</surname> <given-names>J</given-names>
</name>
<name>
<surname>Heist</surname> <given-names>R</given-names>
</name>
</person-group>. <article-title>Seminar lung cancer</article-title>. <source>Lancet</source> (<year>2021</year>) <volume>398</volume>:<page-range>535&#x2013;54</page-range>. doi: <pub-id pub-id-type="doi">10.1016/S0140-6736(21)00312-3</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Siegel</surname> <given-names>RL</given-names>
</name>
<name>
<surname>Miller</surname> <given-names>KD</given-names>
</name>
<name>
<surname>Jemal</surname> <given-names>A</given-names>
</name>
</person-group>. <article-title>Cancer statistics, 2020</article-title>. <source>CA Cancer J Clin</source> (<year>2020</year>) <volume>70</volume>(<issue>1</issue>):<fpage>7</fpage>&#x2013;<lpage>30</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.3322/caac.21590</pub-id>
</citation>
</ref>
<ref id="B4">
<label>4</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Molina</surname> <given-names>JR</given-names>
</name>
<name>
<surname>Yang</surname> <given-names>P</given-names>
</name>
<name>
<surname>Cassivi</surname> <given-names>SD</given-names>
</name>
<name>
<surname>Schild</surname> <given-names>SE</given-names>
</name>
<name>
<surname>Adjei</surname> <given-names>AA</given-names>
</name>
</person-group>. <article-title>Non-small cell lung cancer: epidemiology, risk factors, treatment, and survivorship</article-title>. <source>Mayo Clin Proc</source> (<year>2008</year>) <volume>83</volume>(<issue>5</issue>):<page-range>584&#x2013;94</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.4065/83.5.584</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhu</surname> <given-names>Z</given-names>
</name>
<name>
<surname>Miao</surname> <given-names>W</given-names>
</name>
<name>
<surname>Li</surname> <given-names>Q</given-names>
</name>
<name>
<surname>Dai</surname> <given-names>H</given-names>
</name>
<name>
<surname>Ma</surname> <given-names>Q</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>99mtc-3prgd2 for integrin receptor imaging of lung cancer: a multicenter study</article-title>. <source>J Nucl Med</source> (<year>2012</year>) <volume>53</volume>(<issue>5</issue>):<page-range>716&#x2013;22</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.111.098988</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Apostolopoulos</surname> <given-names>ID</given-names>
</name>
<name>
<surname>Papathanasiou</surname> <given-names>ND</given-names>
</name>
<name>
<surname>Spyridonidis</surname> <given-names>T</given-names>
</name>
<name>
<surname>Apostolopoulos</surname> <given-names>DJ</given-names>
</name>
</person-group>. <article-title>Automatic characterization of myocardial perfusion imaging polar maps employing deep learning and data augmentation</article-title>. <source>Hell J Nucl Med</source> (<year>2020</year>) <volume>23</volume>(<issue>2</issue>):<page-range>125&#x2013;32</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1967/s002449912101</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname> <given-names>J</given-names>
</name>
<name>
<surname>Shi</surname> <given-names>L</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>R</given-names>
</name>
<name>
<surname>Miller</surname> <given-names>EJ</given-names>
</name>
<name>
<surname>Sinusas</surname> <given-names>AJ</given-names>
</name>
<name>
<surname>Liu</surname> <given-names>C</given-names>
</name>
<etal/>
</person-group>. <article-title>Direct attenuation correction using deep learning for cardiac spect: a feasibility study</article-title>. <source>J Nucl Med</source> (<year>2021</year>) <volume>62</volume>(<issue>11</issue>):<page-range>1645&#x2013;52</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.120.256396</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sara</surname> <given-names>U</given-names>
</name>
<name>
<surname>Akter</surname> <given-names>M</given-names>
</name>
<name>
<surname>Uddin</surname> <given-names>MS</given-names>
</name>
</person-group>. <article-title>Image quality assessment through fsim, ssim, mse and psnr&#x2013;a comparative study</article-title>. <source>J Comput Commun</source> (<year>2019</year>) <volume>7</volume>(<issue>3</issue>):<fpage>8</fpage>&#x2013;<lpage>18</lpage>. doi: <pub-id pub-id-type="doi">10.4236/jcc.2019.73002</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kanzaki</surname> <given-names>T</given-names>
</name>
<name>
<surname>Takahashi</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Higuchi</surname> <given-names>T</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>X</given-names>
</name>
<name>
<surname>Mogi</surname> <given-names>N</given-names>
</name>
<name>
<surname>Suto</surname> <given-names>T</given-names>
</name>
<etal/>
</person-group>. <article-title>Evaluation of 111in-pentetreotide spect imaging correction for gep-net</article-title>. <source>J Nucl Med Technol</source> (<year>2020</year>) <volume>48</volume>(<issue>4</issue>):<page-range>326&#x2013;30</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnmt.120.249680</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nunez</surname> <given-names>M</given-names>
</name>
<name>
<surname>Prakash</surname> <given-names>V</given-names>
</name>
<name>
<surname>Vila</surname> <given-names>R</given-names>
</name>
<name>
<surname>Mut</surname> <given-names>F</given-names>
</name>
<name>
<surname>Alonso</surname> <given-names>O</given-names>
</name>
<name>
<surname>Hutton</surname> <given-names>BF</given-names>
</name>
</person-group>. <article-title>Attenuation correction for lung spect: evidence of need and validation of an attenuation map derived from the emission data</article-title>. <source>Eur J Nucl Med Mol Imaging</source> (<year>2009</year>) <volume>36</volume>(<issue>7</issue>):<page-range>1076&#x2013;89</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-009-1090-4</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shiraishi</surname> <given-names>S</given-names>
</name>
<name>
<surname>Tomiguchi</surname> <given-names>S</given-names>
</name>
<name>
<surname>Utsunomiya</surname> <given-names>D</given-names>
</name>
<name>
<surname>Kawanaka</surname> <given-names>K</given-names>
</name>
<name>
<surname>Awai</surname> <given-names>K</given-names>
</name>
<name>
<surname>Morishita</surname> <given-names>S</given-names>
</name>
<etal/>
</person-group>. <article-title>Quantitative analysis and effect of attenuation correction on lymph node staging of non-small cell lung cancer on spect and ct</article-title>. <source>AJR Am J Roentgenol</source> (<year>2006</year>) <volume>186</volume>(<issue>5</issue>):<page-range>1450&#x2013;7</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2214/AJR.04.0898</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Presotto</surname> <given-names>L</given-names>
</name>
<name>
<surname>Bettinardi</surname> <given-names>V</given-names>
</name>
<name>
<surname>Bagnalasta</surname> <given-names>M</given-names>
</name>
<name>
<surname>Scifo</surname> <given-names>P</given-names>
</name>
<name>
<surname>Savi</surname> <given-names>A</given-names>
</name>
<name>
<surname>Vanoli</surname> <given-names>EG</given-names>
</name>
<etal/>
</person-group>. <article-title>Evaluation of a 2d unet-based attenuation correction methodology for Pet/Mr brain studies</article-title>. <source>J Digit Imaging</source> (<year>2022</year>) <volume>35</volume>(<issue>3</issue>):<page-range>432&#x2013;45</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s10278-021-00551-1</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Torkaman</surname> <given-names>M</given-names>
</name>
<name>
<surname>Yang</surname> <given-names>J</given-names>
</name>
<name>
<surname>Shi</surname> <given-names>L</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>R</given-names>
</name>
<name>
<surname>Miller</surname> <given-names>EJ</given-names>
</name>
<name>
<surname>Sinusas</surname> <given-names>AJ</given-names>
</name>
<etal/>
</person-group>. <article-title>Direct image-based attenuation correction using conditional generative adversarial network for spect myocardial perfusion imaging</article-title>. <source>Proc SPIE Int Soc Opt Eng</source> (<year>2021</year>). doi:&#xa0;<pub-id pub-id-type="doi">10.1117/12.2580922</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>