Abstract
Multiple myeloma (MM) progression and therapeutic resistance are dictated by the bone marrow microenvironment (BMME). Conventional single-marker immunohistochemistry (IHC) cannot resolve the complex cellular neighborhoods, non-cellular signaling networks, and spatial exclusion patterns that characterize this disease. Multiplex immunohistochemistry (mIHC) and allied high-plex spatial imaging technologies now enable simultaneous visualization of 6 to over 60 protein targets on a single formalin-fixed paraffin-embedded (FFPE) section while preserving tissue architecture. This review first establishes a rigorous technical foundation by reclassifying mIHC and related high-dimensional imaging platforms according to their detection readout modality—fluorescence spectral unmixing/tyramide signal amplification (TSA) cyclic staining, DNA-barcode cyclic hybridization, metal-isotope mass spectrometric imaging, and regional-photolysis digital spatial profiling—and by clarifying several long-standing technical misconceptions (e.g., the historical relationship between PhenoCycler and Vectra Polaris, the cyclic nature of the Opal/TSA workflow, and the true elution chemistry of CODEX and t-CyCIF). We then present an expanded, bone-marrow-specific horizontal comparison of mIHC against flow cytometry, mass cytometry (CyTOF), imaging mass cytometry (IMC)/multiplexed ion beam imaging (MIBI), and spatial transcriptomics. Building on this technical scaffold, we organize the biological and clinical applications of mIHC along the natural disease continuum—monoclonal gammopathy of undetermined significance (MGUS) → smoldering myeloma (SMM) → newly diagnosed MM (NDMM) → post-treatment residual disease → relapsed/refractory MM (RRMM) → extramedullary disease (EMD)—integrating T-cell, stromal, myeloid, and NK-cell compartments together with cytokine networks, metabolic competition, and bone-remodeling signals. We further delineate realized multimodal integration paradigms (mIHC combined with spatial transcriptomics, single-cell RNA sequencing, digital spatial profiling, and artificial intelligence) and, separately, the technical, economic, and workflow bottlenecks—including spectral overlap, antibody cross-reactivity, turnaround time, cost, and the choice between bone marrow clot and decalcified trephine specimens—that currently constrain clinical translation. As methodological workflows for decalcified bone marrow specimens mature, mIHC is transitioning from a research tool to a critical component of precision immuno-oncology, offering actionable insights for overcoming CAR-T resistance and improving risk stratification.
1 Introduction
1.1 The evolving therapeutic landscape of multiple myeloma
Multiple myeloma (MM) is a clonal hematologic malignancy driven by the proliferation of neoplastic plasma cells within the bone marrow niche, and remains the second most prevalent hematologic malignancy worldwide (1). Over the past two decades, the therapeutic landscape of MM has undergone successive paradigm shifts: the introduction of proteasome inhibitors (PIs, e.g., bortezomib, carfilzomib) and immunomodulatory drugs (IMiDs, e.g., lenalidomide, pomalidomide) markedly improved response rates in the 2000s; the subsequent addition of monoclonal antibodies targeting CD38 (daratumumab) and SLAMF7 (elotuzumab) further deepened responses and became a backbone of frontline quadruplet regimens (2). Most recently, T-cell redirecting immunotherapies—BCMA- or GPRC5D-directed chimeric antigen receptor (CAR) T-cell products and bispecific T-cell engagers (BiTEs)—have achieved unprecedented response rates in heavily pretreated relapsed/refractory MM (RRMM) (3). Despite these breakthroughs, MM remains incurable for the vast majority of patients: minimal residual disease persistence, eventual relapse, and the emergence of extramedullary disease (EMD) are increasingly attributed to the complex, protective, and immunosuppressive architecture of the bone marrow microenvironment (BMME), which shelters residual clones, drives immune escape, and confers therapeutic resistance (4, 5). This growing recognition that the BMME—not merely the malignant plasma cell clone—governs therapeutic outcome is the central rationale for this review: technologies capable of resolving the BMME’s cellular and molecular architecture in situ are now indispensable for guiding the next generation of precision immunotherapy in MM (6, 7).
1.2 Rationale for spatially resolved profiling
Standard histopathological assessment—hematoxylin-eosin staining or single-marker IHC—provides morphological detail but cannot capture the multi-dimensional cellular interactions that drive disease evolution. Flow cytometry and single-cell RNA sequencing (scRNA-seq) enable high-dimensional phenotyping of bone marrow aspirates, but both require tissue dissociation into single-cell suspensions, irrevocably destroying the spatial context that defines the marrow niche (8, 9). Multiplex immunohistochemistry (mIHC)—used here as an umbrella term encompassing multiplex immunofluorescence (mIF)—bridges this gap: by enabling concurrent detection of numerous protein targets on a single intact FFPE section, mIHC preserves the in situ spatial architecture and permits precise mapping of cellular neighborhoods, intercellular distances, and spatial exclusion patterns that predict therapeutic outcome (10, 11).
1.3 A technical anchor: principles, advantages, and workflow of mIHC
Unlike conventional single-plex IHC, which restricts analysis to one or two markers per slide, mIHC platforms enable simultaneous visualization of high-dimensional protein markers (typically 6 to over 60) on a single tissue section while retaining spatial and morphological information (12). The effective implementation of mIHC rests on three interdependent pillars that will recur throughout this review and therefore merit brief definition here:
Panel design and antibody validation. Biomarker selection must balance biological relevance against the practical constraints of spectral separation (for fluorescence-based platforms) or isotopic mass separation (for metal-based platforms). Each antibody clone requires orthogonal validation against single-plex IHC to exclude cross-reactivity and to establish an appropriate signal-to-noise threshold before being incorporated into a multiplex panel (13).
Detection modality. Distinct chemistries — fluorescence spectral unmixing with tyramide signal amplification (TSA), DNA-barcode cyclic hybridization, metal-isotope mass spectrometric imaging, and regional photolysis of oligonucleotide tags — underlie the different platform families discussed in Section 2, and dictate each platform’s plexing ceiling, tissue-destructiveness, and throughput.
Computational workflow. Raw multi-channel images must undergo tissue/cycle registration, spectral or mass unmixing, single-cell segmentation, marker-based cell phenotyping, and finally spatial statistical analysis (e.g., nearest-neighbor distance, cellular neighborhood enrichment) before biological or clinical inference can be drawn. Increasingly, this pipeline is being augmented by artificial intelligence (AI) and deep learning for automated segmentation and pattern discovery (14).
By providing a high-resolution, in situ atlas of the tumor-immune ecosystem, mIHC bridges molecular biology and clinical pathology. In the sections that follow, we (i) rigorously classify mIHC and allied spatial imaging platforms by detection modality and correct several recurring technical misconceptions (Section 2); (ii) situate mIHC within the broader landscape of spatial and single-cell profiling technologies, with explicit attention to bone-marrow-specific constraints (Section 3); (iii) synthesize the biological and clinical insights that mIHC has generated across the MM disease continuum (Section 4); (iv) summarize realized multimodal integration paradigms (Section 5); (v) detail mIHC’s emerging role in treatment response evaluation and prognostic stratification (Section 6); and (vi) critically examine the technical, economic, and pre-analytical bottlenecks that must be overcome for routine clinical translation (Section 7). The overall cellular/molecular architecture of the MM BMME that motivates this technical and clinical synthesis is summarized graphically in Figure 1.
Figure 1
2 Technical principles and established mIHC platforms
2.1 Platform classification by detection readout modality
Multiplex immunohistochemistry and multiplex immunofluorescence have emerged as cornerstone technologies for spatially resolved proteomic profiling (11, 15). Rather than classifying platforms solely by “whether cyclic imaging is used”—a criterion that is internally inconsistent, since the Opal/TSA workflow itself relies on iterative staining cycles—we classify established platforms according to their underlying detection readout modality, which more accurately reflects their chemistry, plexing ceiling, tissue-destructiveness, and bone-marrow compatibility (Figure 2).
Figure 2
2.1.1 Fluorescence spectral unmixing with tyramide signal amplification-based cyclic staining
Represented primarily by the Opal™ multiplex system (Akoya Biosciences, formerly PerkinElmer), this modality combines tyramide signal deposition with multispectral imaging (16, 17). Horseradish peroxidase (HRP)-conjugated secondary antibodies deposit covalently bound fluorophore-tyramide complexes onto target epitopes; because the covalent deposition is irreversible, the primary/secondary antibody complex can subsequently be stripped or heat-inactivated and the next marker’s antibody applied to the same slide. Correction of a common misconception: Opal/TSA is therefore not a single “simultaneous” one-step incubation that detects 6–8 markers at once; rather, it is inherently an iterative, cyclic staining process in which each round contributes a small number of spectrally distinct fluorophores (typically 4–6 per round), with total panel plexity (7 to >9 markers) achieved by stacking multiple staining–imaging–stripping cycles on the same section, followed by computational spectral unmixing to resolve overlapping emission spectra and subtract tissue autofluorescence (18). Correction regarding instrumentation: The Vectra® Polaris scanner (now marketed within Akoya’s PhenoImager series) is the multispectral imaging hardware used to visualize Opal/TSA-stained slides; it is a TSA-based multispectral scanner and should not be conflated with the DNA-barcode-based PhenoCycler platform (see below), despite both being sold by Akoya.
2.1.2 DNA-barcode cyclic hybridization
CODEX® (CO-Detection by indEXing), commercialized as PhenoCycler®, operates on a fundamentally different chemical principle from TSA-based methods. Antibodies are conjugated to unique, non-fluorescent oligonucleotide barcodes; a cocktail of fluorescently labeled complementary reporter oligonucleotides is then hybridized to these barcodes for one imaging cycle (19, 20). Correction of platform lineage: PhenoCycler originates from CODEX technology (renamed following Akoya’s acquisition of the CODEX platform) and is fundamentally a DNA-barcode cyclic-imaging system; describing it as “formerly the Vectra Polaris” or as “TSA-based cycling” is incorrect and should be avoided, as the two platforms differ in both antibody-labeling chemistry and signal-removal mechanism. Correction of elution mechanism: between imaging cycles, reporter oligonucleotides are removed from the DNA barcodes through a chemical or thermal denaturation/elution step (e.g., stringent buffer washes), not through “computational subtraction”—computation in CODEX is used exclusively for downstream image registration, background correction, and multi-cycle stitching, not for signal removal itself (21). This chemistry allows CODEX/PhenoCycler to reach 40–100+ markers on a single FFPE section with minimal cumulative photobleaching.
2.1.3 Cyclic immunofluorescence with photobleaching or chemical quenching
Tissue-based cyclic immunofluorescence (t-CyCIF) and multiplexed immunofluorescence (MxIF) both use iterative rounds of conventional fluorophore-conjugated antibody staining followed by in situ signal erasure between cycles. Correction of quenching chemistry: t-CyCIF erases signal via chemical bleaching (e.g., hydrogen-peroxide-based oxidation under alkaline/high-light conditions) or, in some MxIF implementations, via mild chemical inactivation of the fluorophore—not via “photocleavable dyes,” which are instead a defining feature of oligonucleotide-tag-based digital spatial profiling (see 2.1.4) (15, 22). Because t-CyCIF and MxIF rely on standard, off-the-shelf fluorophore-conjugated antibodies rather than proprietary barcodes or metal tags, they offer relatively low reagent cost and high antibody flexibility, at the expense of longer per-cycle bleaching times and cumulative tissue photodamage across many cycles.
2.1.4 Metal-isotope mass spectrometric imaging
Imaging mass cytometry (IMC; commercialized as the Hyperion™ system) and multiplexed ion beam imaging (MIBI, IONPath) dispense with fluorescence entirely. Antibodies are conjugated to rare-earth metal isotopes or metal-oxide nanoparticle tags; a focused laser (IMC) or ion beam (MIBI) ablates the tissue pixel-by-pixel, and the liberated metal ions are quantified by time-of-flight mass spectrometry (23, 24). Because natural biological tissue contains essentially no endogenous heavy-metal signal, this modality achieves virtually zero spectral/autofluorescence overlap and can resolve 40+ markers simultaneously at subcellular (~1 μm) resolution, at the cost of destructive tissue ablation, a comparatively small field of view per acquisition, and slower throughput than optical platforms (25).
2.1.5 Regional photolysis-based digital spatial profiling
The GeoMx Digital Spatial Profiler (DSP; NanoString/Bruker) uses UV-cleavable oligonucleotide tags conjugated to antibodies (protein panels) or in situ hybridization probes (whole-transcriptome panels). A focused UV beam photolytically releases the oligonucleotide tags from a user-defined region of interest (ROI), which are then collected and quantified by next-generation sequencing or a nCounter-based hybridization readout (26). Because quantification is performed on pooled photo-released tags from an entire ROI rather than on a segmented single-cell image, GeoMx DSP does not natively provide single-cell spatial resolution; it is therefore best characterized as a digital spatial (ROI-averaged) profiling technology rather than a strict single-cell mIHC platform (see Section 2.3 for further discussion of its positioning).
Emerging platforms not yet widely applied to MM but relevant to a comprehensive technical landscape include MACSima™ (Miltenyi Biotec), an automated iterative immunofluorescence system using reversible fluorescent Fab-fragment probes that achieves high-plex profiling (>40 markers) while remaining compatible with standard fluorophore panels (27); InSituPlex® (Ultivue), a signal-amplification-based automated multiplex immunofluorescence workflow optimized for rapid whole-slide staining and scanning (28); and the Orion™ platform (RareCyte), which combines multiplexed fluorescence detection with a co-registered hematoxylin-eosin (H&E) image on the same section, facilitating direct correlation between molecular phenotype and conventional morphology (29).
2.2 Technical challenges specific to bone marrow microenvironment analysis
While mIHC principles are well established in solid-tumor pathology, applying these platforms to the bone marrow microenvironment (BMME) introduces distinct pre-analytical and analytical hurdles that must be explicitly addressed:
Antigen loss via decalcification. FFPE bone marrow trephine biopsies require decalcification (commonly EDTA-based chelation or, less desirably, stronger acid-based methods) to permit sectioning of mineralized trabecular bone. This process can substantially mask or destroy epitopes—particularly phosphorylated proteins and certain surface antigens—often necessitating extended or modified antigen-retrieval protocols and careful antibody re-validation on decalcified tissue before inclusion in a multiplex panel (30, 31).
High lipid content and autofluorescence. Bone marrow is rich in adipocytes and contains dense trabecular bone, both of which generate substantial endogenous autofluorescence that can obscure specific antigen signal, particularly in the green–yellow emission range used by many TSA fluorophores. Dedicated autofluorescence-quenching steps (e.g., Sudan Black B treatment) or computational background-subtraction algorithms during spectral unmixing are essential for accurate quantification in marrow tissue (32).
Sample fragility. Decalcified marrow sections are notoriously fragile and prone to detachment from slides during the repeated staining, washing, and stripping cycles required for high-plex panels; the use of positively charged adhesive slides and optimized baking/adhesion protocols is therefore critical to preserve tissue integrity across an entire cyclic mIHC or CODEX run.
Choice of specimen type. Bone marrow can be sampled either as an aspirate clot section or as a decalcified trephine biopsy, and this choice carries direct consequences for mIHC feasibility (elaborated in Section 7.3): clot sections avoid decalcification-related antigen loss and better preserve labile immune-cell surface markers, but sample only a small, potentially non-representative volume of marrow and lack information on trabecular/stromal architecture; trephine biopsies preserve the full spatial architecture of the niche but are subject to variable antigen degradation depending on decalcification protocol and duration (30, 33).
2.3 Platform positioning: what counts as “mIHC”?
Given the diversity of detection chemistries described above, it is useful to explicitly delineate which platforms fall within a strict definition of mIHC/mIF versus which are better classified as broader spatial multi-omics technologies:
Strictly mIHC/mIF: the Opal/TSA platform, MxIF, and t-CyCIF all perform antibody-based immunostaining with optical (fluorescence or chromogenic) readout and single-cell-resolved images, and therefore fall squarely within the traditional definition of mIHC/mIF.
Broad spatial proteomics/multi-omics, adjacent to but distinct from traditional mIHC: CODEX/PhenoCycler, although antibody-based, relies on DNA-barcode hybridization chemistry rather than direct fluorophore or chromogen deposition, and is more accurately described as a high-dimensional spatial proteomics platform; IMC and MIBI substitute mass spectrometry for optical detection entirely. GeoMx DSP, as discussed in Section 2.1.5, lacks native single-cell resolution and is best classified as a digital (ROI-averaged) spatial profiling technology rather than a strict mIHC platform, despite frequently being discussed alongside mIHC in the spatial biology literature. We adopt this more precise terminology throughout the remainder of this review, using “mIHC/mIF” for the strictly antibody-optical platforms and “high-plex spatial imaging” or naming the specific platform (CODEX/PhenoCycler, IMC/MIBI, GeoMx DSP) when discussing the broader family.
2.4 Horizontal Comparison of mIHC and allied high-plex imaging platforms
Table 1 provides an expanded horizontal comparison of established platforms, incorporating multiplexing capacity, spatial resolution, tissue-destructiveness, cost, throughput, and—critically—their demonstrated or anticipated compatibility with bone marrow specimens, addressing a key gap in prior comparative summaries.
Table 1
| Platform | Detection modality | Multiplexing capacity | Spatial resolution | Tissue integrity | Key advantages | Key limitations | Bone marrow applicability |
|---|---|---|---|---|---|---|---|
| Opal (Akoya)/TSA | Tyramide signal amplification + spectral unmixing (cyclic) | 6–9+ per panel (14) | Subcellular (~0.25 µm) | Preserved (FFPE) | High sensitivity; extensive clinical/CDx validation (e.g., PD-L1) | Cyclic bleaching limits total cycles; spectral overlap requires unmixing; autofluorescence-prone in fatty marrow | Feasible on decalcified trephines with autofluorescence quenching; validated in myeloma BM studies (9) |
| PhenoCycler/CODEX (Akoya) | DNA-barcode cyclic hybridization | 40–100+ (17) | Subcellular (~0.25 µm) | Preserved (FFPE); minimal photodamage per cycle | High-dimensional single-cell proteomics; no spectral overlap; scalable plexity | Long acquisition time; requires barcode-antibody conjugation and validation | Recently adapted for fragile decalcified BM trephines (29) |
| t-CyCIF/MxIF | Iterative immunofluorescence with chemical bleaching/quenching | 20–60 (cumulative cycles) (20) (13) | Subcellular (~0.3 µm) | Preserved (FFPE) | Uses standard off-the-shelf antibodies; flexible panel design | Cumulative photobleaching/tissue loss over many cycles; slow | Applicable to marrow with optimized bleaching cycles; limited myeloma-specific validation |
| IMC (Hyperion) | Metal-isotope laser ablation + mass spectrometry | 40+ (21) | Subcellular (~1 µm) | Destructive (ablated) | Zero spectral overlap; no autofluorescence; tolerant of decalcified tissue | Small field of view; slow throughput; expensive | Advantageous for decalcified BM trephines — demonstrated in diagnostic MM core biopsies (31) |
| MIBI (IONPath) | Ion-beam ablation + mass spectrometry | 40–60+ (22) | Subcellular (~1 µm) | Destructive (ablated) | High dynamic range; excellent for rare cell phenotyping | Destructive; specialized infrastructure; limited throughput | Emerging; theoretically compatible with decalcified marrow but limited published MM data |
| GeoMx DSP (NanoString) | Oligonucleotide tags released by UV photolysis (ROI-based) | Whole proteome/transcriptome panels (24) | ROI-averaged (not single-cell) | Preserved (FFPE) | Extremely high plex; simultaneous protein + RNA on same section | Lacks single-cell spatial resolution; ROI-selection bias | Validated in BM trephine samples; used for MM immune-niche profiling (24) |
| Flow cytometry | Fluorophore-conjugated antibody + cell suspension | 10–20 (conventional); up to ~28–30 with spectral flow | None (cell suspension) | Destroyed (requires viable single-cell suspension) | High-throughput deep phenotyping; quantitative; clinical MRD standard | No spatial information; requires fresh/viable cells; RBC lysis and anticoagulant handling can bias surface marker expression | Naturally compatible with BM aspirate; IMWG/NCCN standard for MRD |
| CyTOF (mass cytometry) | Metal-isotope-conjugated antibody + suspension mass spectrometry | 40+ (32) (33) | None (cell suspension) | Destroyed | Eliminates spectral overlap of fluorescent flow; high-parameter phenotyping | No spatial context; requires cell dissociation; expensive instrumentation | Applied to BM mononuclear cells for immune-checkpoint landscapes in MM (34) |
| Spatial transcriptomics (Visium) | Spatially barcoded RNA capture | Whole transcriptome (~20,000 genes) | Supra-cellular (55 µm spots) | Preserved | Unbiased transcriptome-wide discovery | Cannot assign transcripts to single cells; indirect protein inference | FFPE Visium enables retrospective BM archive analysis (35) |
| MERFISH/seqFISH (in situ hybridization) | Combinatorial barcoded RNA FISH | 10,000+ RNA targets | Subcellular (~100 nm) | Preserved | Single-cell-resolved transcriptomics at massive multiplexity | Limited to RNA targets; complex instrumentation; largely optimized for fresh/frozen tissue | Limited; decalcification generally incompatible with current protocols |
Comparison of mIHC and allied high-plex spatial imaging platforms for bone marrow microenvironment (BMME) analysis.
cost, turnaround time, antibody/reagent availability, and clinical-translation maturity for each platform are discussed narratively in Sections 3 and 7, and are summarized quantitatively in Table 2 (Section 3).
3 Comparative positioning of mIHC among spatial and single-cell profiling technologies for the bone marrow microenvironment
Having established the internal technical taxonomy of mIHC and allied high-plex imaging platforms (Section 2), we now situate mIHC within the broader ecosystem of single-cell and spatial technologies used to interrogate the BMME, with explicit attention to the bone-marrow-specific trade-offs that determine which technology is best suited to a given research or clinical question.
3.1 Flow cytometry: complementary strengths and inherent limitations
Flow cytometry remains the clinical gold standard for BMME immune-cell quantification and minimal residual disease (MRD) detection under International Myeloma Working Group (IMWG) guidelines. Describing it merely as “quantifying cell suspensions without location data” underrepresents both its capabilities and its constraints. Conventional fluorescent flow cytometry resolves 10–20 parameters per tube, whereas cytometry by time-of-flight (CyTOF) extends this to 40+ protein targets by substituting metal-isotope tags for fluorophores and thereby eliminating spectral overlap (34, 35). Flow cytometry’s principal advantage is deep phenotypic characterization of tumor-infiltrating lymphocytes and plasma cells directly from bone marrow aspirates, at a throughput (>10,000 cells/second) that no imaging-based platform can match. Conversely, flow cytometry imposes stringent pre-analytical requirements: viable single-cell suspensions are mandatory, precluding analysis of archived FFPE specimens or decalcified trephine biopsies; red blood cell lysis, Ficoll density-gradient separation, and anticoagulant handling can introduce sampling bias and alter surface marker expression; and, most importantly, complete dissociation of tissue architecture eliminates any ability to resolve the spatial relationships that define BMME pathology. Flow cytometry and mIHC are therefore fundamentally complementary rather than competitive technologies—flow remains indispensable for MRD monitoring and rapid immunophenotyping of aspirates, while mIHC uniquely captures spatial organization in trephine sections.
3.2 CyTOF and imaging mass cytometry/MIBI
CyTOF (mass cytometry) has been applied directly to MM bone marrow mononuclear cells to map immune-checkpoint landscapes and identify distinct T-cell exhaustion signatures across disease stages (36). However, like flow cytometry, CyTOF requires tissue dissociation and cannot provide spatial context. Imaging mass cytometry (IMC; Hyperion system) bridges this gap by combining metal-tagged antibodies with laser ablation and mass-spectrometric detection directly on intact tissue sections, achieving subcellular spatial resolution (~1 μm) at 40+ markers (24). IMC’s key advantage for bone marrow studies is its tolerance to decalcified FFPE specimens (29), the standard preparation method for BM trephine biopsies: because signal is generated by mass spectrometry rather than fluorescence, IMC entirely bypasses the autofluorescence problem that complicates optical mIHC in lipid-rich, trabecular marrow tissue. Imaging mass cytometry has been directly applied to diagnostic bone marrow core biopsies from MM patients, revealing cellular-neighborhood signatures with prognostic and demographic associations (37). MIBI operates on an analogous ion-beam-ablation principle and offers similarly high dynamic range for rare-cell phenotyping (23, 25). Nevertheless, the destructive laser/ion-beam ablation used by both IMC and MIBI limits the field of view per acquisition run, and throughput remains substantially lower than optical mIHC platforms, constraining their utility for large-scale clinical screening.
3.3 Spatial transcriptomics: from discovery to validation
Spatial transcriptomics technologies (10x Genomics Visium, NanoString GeoMx, MERFISH, seqFISH, DBiT-seq, Stereo-seq) represent the discovery-oriented, RNA-centric counterpart to protein-centric mIHC. Visium’s ~55 μm spot resolution captures whole-transcriptome expression from thousands of spatially indexed positions, enabling unbiased identification of cell-type-specific gene-expression programs within the BM niche, and FFPE-compatible Visium chemistry now permits retrospective analysis of archived marrow biopsies (38). However, Visium’s supra-cellular resolution cannot assign transcripts unambiguously to individual cells. Emerging in situ hybridization platforms such as MERFISH and seqFISH achieve subcellular (~100 nm) resolution and can detect 10,000+ RNA species simultaneously, but remain largely optimized for fresh/frozen tissue and are not yet routinely compatible with decalcified marrow. These platforms are transforming BMME research from protein-level phenotyping toward comprehensive spatial multi-omics, in which mIHC increasingly serves not merely as a validator but as a co-equal orthogonal dimension of spatial biology (elaborated in Section 3.4).
3.4 mIHC as a co-equal dimension within multimodal spatial omics
Framing mIHC as merely “protein-level validation” of transcriptomic data understates its role in the current spatial-biology ecosystem. Same-slide multi-omics approaches and co-registration pipelines increasingly position mIHC as an integral, co-equal dimension of multimodal spatial biology, contributing several defining advantages beyond the single property of spatial preservation:
Preservation of in situ spatial architecture with subcellular resolution;
Simultaneous detection of multiple protein markers on a single FFPE section;
Quantitative protein expression measurement with retained morphological context;
Broad FFPE/biobank compatibility, enabling retrospective studies of archived diagnostic specimens that are inaccessible to dissociative single-cell methods (flow cytometry, CyTOF, most scRNA-seq protocols).
In this framework, transcriptomics defines the molecular identity (“what”), mIHC defines the spatial localization and protein abundance (“where” and “how much”), and increasingly AI-driven spatial modeling integrates these dimensions into predictive clinical frameworks (Section 5.4).
3.5 Expanded horizontal comparison table
Table 2 expands the comparison introduced in Table 1 to explicitly incorporate cost, throughput, processing speed, antibody/reagent availability, biobank compatibility, and — critically for this review — bone-marrow-specific applicability for each major technology class, directly addressing the “generic technical comparison” limitation of earlier summary tables.
Table 2
| Dimension | Conventional IHC | Flow cytometry | mIHC (TSA/cyclic) | CyTOF (mass cytometry) | IMC/MIBI | Spatial transcriptomics (Visium) | In situ hybridization (MERFISH/seqFISH) |
|---|---|---|---|---|---|---|---|
| Multiplexing capacity | 1–3 markers | 10–20 (fluorescent); up to 40+ with spectral flow (32) | 6–60+ (10) (17) | 40–50+ protein targets (33) | 40+ (IMC); 40–60+ (MIBI) (21) (22) | Whole transcriptome (~20,000 genes) | 10,000+ RNA targets |
| Spatial resolution | Cellular (~200 nm) | None (suspension) | Subcellular (~0.25 µm) | None (suspension) | Subcellular (~1 µm) | Supra-cellular (55 µm spots) | Subcellular (~100 nm) |
| Morphological context | Yes | No | Yes | No | Yes (ablated section) | Yes (H&E co-registration) | Yes |
| Tissue architecture | Preserved | Destroyed (requires viable suspension; RBC lysis/anticoagulant handling) | Preserved; substantially less tissue-consuming than sequential single-plex IHC on separate sections | Destroyed | Preserved (section-based, though locally ablated during acquisition) | Preserved | Preserved |
| FFPE/archival compatibility | Yes | No (fresh viable cells only) | Yes — key advantage for biobanked specimens | No (fresh/frozen viable cells) | Yes, including decalcified marrow (31) | Yes (FFPE Visium available) (35) | Limited (optimized for fresh/frozen) |
| Throughput | High (routine clinical) | Very high (>10,000 cells/s) | Moderate (1–3 slides/day, panel-dependent) | High (>1,000 cells/s) | Low–moderate (hours/section) | Moderate | Low |
| Processing speed (TAT) | 1–2 days | Hours | 2–4 days (multi-cycle staining/imaging/analysis for a 6–8-plex panel) (16) | Hours | 1–3 days | 1–2 weeks (library prep + sequencing) | 1–2 weeks |
| Cost per sample (approximate) | Low | Moderate | High (instrument capital cost + premium reagents) | High | Very high | High | Very high |
| Antibody/reagent availability | Extensive | Extensive | Moderate–high (requires TSA/cyclic optimization) | Moderate (metal conjugation) | Moderate (metal-tagged antibodies) | N/A (probe-based) | Extensive (commercial probe sets) |
| Quantitative precision | Semi-quantitative (H-score) | High | Moderate–high | High | High | High (UMI-based) | High |
| Analytical complexity | Low | Moderate | High (spectral unmixing, segmentation, spatial statistics) | High | High | Very high (bioinformatics pipeline) | Very high |
| Bone marrow applicability | Routine for BM clot and trephine sections | Naturally compatible with BM aspirate single-cell suspensions (standard diagnostic workflow) | Feasible on decalcified trephines with autofluorescence quenching; better suited to clot sections for immune-cell-surface-marker-sensitive panels | Requires fresh BM aspirate, not trephine | Advantageous for decalcified BM trephine — tolerant of standard diagnostic processing (31) | Emerging (FFPE Visium enables retrospective BM archive analysis) (35) | Limited (decalcification generally incompatible) |
| Clinical translation maturity | Established (WHO/ICC diagnostic standard) | Established (IMWG/NCCN guideline; MRD assessment) | Emerging (laboratory-developed test; pre-clinical/translational research stage) | Emerging (research stage) | Early research | Early research | Proof of concept |
Comprehensive comparison of single-cell and spatial technologies for bone marrow microenvironment characterization.
As Table 2 makes explicit, no single technology is universally superior for BMME characterization: flow cytometry’s natural compatibility with bone marrow aspirate single-cell suspensions makes it irreplaceable for routine MRD monitoring; IMC’s tolerance of decalcified, FFPE-processed trephine sections makes it particularly well suited to retrospective diagnostic archives; and mIHC occupies the intermediate niche of moderate-to-high multiplexing with full spatial preservation on the same FFPE trephine or clot sections already collected for routine diagnosis—provided that decalcification-related antigen loss and marrow autofluorescence are actively managed (Section 7.1, 7.3).
4 Applications of mIHC in elucidating the multiple myeloma bone marrow microenvironment: a disease-continuum perspective
4.1 Global cellular and molecular architecture of the MM BMME
Before tracing stage-specific findings, it is necessary to establish the full compositional and functional scope of the BMME that mIHC studies are increasingly capturing. The MM bone marrow niche comprises not only the T-cell and plasma-cell compartments most frequently profiled by early mIHC studies, but also several additional cellular and non-cellular components whose spatial organization is now recognized as biologically consequential:
Cellular compartments: clonal plasma cells; CD4+, CD8+, and regulatory T-cell (Treg) subsets; natural killer (NK) cells; myeloid populations including M2-polarized macrophages and myeloid-derived suppressor cells (MDSCs); and bone-marrow stromal cells (BMSCs, including cancer-associated fibroblast-like mesenchymal stromal cells), osteoclasts, and osteoblasts (4, 39).
Non-cellular components: cytokine and chemokine networks (e.g., IL-6, TGF-β, CXCL12), extracellular matrix (ECM) remodeling, and soluble immunosuppressive factors that collectively shape the “inflammatory stromal cell landscape” now recognized as a defining feature of the MM microenvironment (4).
Functional dimensions beyond immune surveillance/escape: bone metabolism (osteoclast/osteoblast uncoupling driving osteolytic lesions), angiogenesis, and metabolic competition for nutrients between tumor and immune cells, all of which interact with — rather than operate independently of — the immune-exclusion phenomena that dominated earlier mIHC literature (5, 40).
Single-cell atlas studies have shown that BMSCs in MM adopt an inflammatory transcriptional state that reprograms neighboring myeloid cells toward an immunosuppressive, tumor-permissive phenotype, and that this stromal remodeling is detectable from the earliest premalignant stages (4). Single-cell and spatial proteomic studies have further demonstrated that MM bone marrow stromal cells adopt distinct inflammatory states that reprogram the immune landscape across disease stages, and that high-dimensional multiplex imaging can spatially map these cellular interactions within intact marrow architecture (6, 41). Complementary single-cell work has demonstrated macrophage reprogramming toward an M2-like, tumor-supportive phenotype and coordinated dysfunction of T- and NK-cell compartments across the MM immune microenvironment (39). These non-lymphocytic and non-cellular dimensions are only beginning to be captured by high-plex spatial imaging and represent an important frontier for future mIHC panel design (see Section 7.2).
4.2 Precursor states: MGUS and smoldering myeloma
The transition from monoclonal gammopathy of undetermined significance (MGUS) through smoldering myeloma (SMM) to active MM involves progressive, spatially organized remodeling of the BMME rather than an abrupt phenotypic switch. Single-cell and spatial studies spanning the full disease spectrum have shown that immune dysregulation—including expansion of exhausted T-cell subsets and progressive stromal inflammatory activation—is already detectable at the MGUS/SMM stage and intensifies incrementally with progression to active MM (42, 43). At the molecular-signaling level, digital spatial profiling of high-risk SMM bone marrow has shown that early alterations in immune-cell metabolic states—specifically, shifts in glycolytic and oxidative-phosphorylation-related protein expression within T-cell and myeloid compartments—correlate with subsequent risk of progression to symptomatic MM, suggesting that metabolic-immune crosstalk is an early, rather than late, event in disease evolution (43). Comprehensive analyses of immune checkpoint dynamics across the MGUS–RRMM disease continuum have confirmed that progressive remodeling of inhibitory receptor expression (PD-1, LAG-3, TIM-3, TIGIT) on bone marrow T-cell subsets is detectable from premalignant stages and intensifies with advancing disease (44). Functionally, this metabolic-immune remodeling is hypothesized to compromise the surveillance capacity of resident cytotoxic lymphocytes well before clinically overt progression, providing a rationale for using spatial immune-metabolic biomarkers as risk-stratification tools in SMM (elaborated in Section 6.2).
4.3 Newly diagnosed multiple myeloma: establishing the immune-exclusion paradigm
In newly diagnosed, treatment-naïve MM, mIHC has been used to establish a foundational spatial paradigm linking T-cell–plasma-cell proximity to immune surveillance. Using mIHC on bone marrow trephine sections, Ninkovic and colleagues mapped the spatial relationship between cytotoxic CD8+ T cells and malignant plasma cells across the disease course: in newly diagnosed patients, CD8+ T cells localized closely to plasma-cell clusters, consistent with active immunosurveillance, whereas relapsed disease exhibited significantly increased physical separation between these populations — an “immune exclusion” phenotype that independently predicted adverse outcome (10). This same study identified LAG-3 as the most upregulated checkpoint receptor on cytotoxic T cells in relapsed myeloma, nominating it as a priority immunotherapeutic target over PD-1 in this clinical setting (37). Building on this spatial-structure-level observation, Hagos and colleagues developed a deep-learning pipeline (MoSaicNet) that automates segmentation of these spatial topologies at scale, confirming across a larger cohort that T-cell–plasma-cell separation distance is a robust and reproducible prognostic marker independent of manual region selection (10). Mechanistically, this body of work illustrates a three-level explanatory chain that recurs throughout this review — spatial structure (increased physical distance between CD8+ T cells and plasma cells) → molecular signaling (LAG-3 checkpoint upregulation on the spatially excluded T-cell population) → functional consequence (attenuated cytotoxic engagement and accelerated relapse) — rather than remaining at the level of purely phenomenological description.
4.4 Immune–metabolic crosstalk and niche-level mechanisms in active MM
Beyond the T-cell–plasma-cell axis, mIHC and allied high-plex imaging have revealed spatially organized metabolic competition as a distinct mechanism of immunosuppression in active MM. Multiplexed imaging of MM bone marrow has demonstrated that stromal and myeloid cells expressing high levels of glucose transporters co-localize with immunosuppressive macrophage populations, forming discrete “immune-metabolic niches” that are spatially segregated from residual effector T-cell zones and are associated with disease progression and osteolytic bone involvement (45). Applying the same three-level mechanistic framework: at the spatial structure level, glucose-transporter-high stromal/myeloid cells and immunosuppressive macrophages form discrete anatomic clusters; at the molecular signaling level, this clustering is accompanied by nutrient (glucose) sequestration away from neighboring lymphocytes and by paracrine immunosuppressive cytokine signaling; and at the functional consequence level, T cells within these metabolic niches display restricted effector capacity, establishing metabolic competition as a spatially organized — rather than a diffusely systemic — driver of local immunosuppression (45).
4.5 Spatial dissection of bone marrow “breakout” lesions and cellular neighborhoods
Focal areas where MM cells breach the endosteal bone surface — termed breakout lesions — represent an anatomically distinct microenvironment within the same marrow specimen. High-dimensional mIF analysis of these lesions has shown that they harbor myeloid and T-cell populations distinct from the surrounding marrow, characterized by higher expression of inhibitory receptors and a more exhausted T-cell phenotype, nominating breakout lesions as critical anatomical reservoirs for disease relapse (43). Complementing this lesion-level analysis, quantitative spatial profiling using a 26-marker mIF panel in patients with high-risk t(4;14) translocation demonstrated that the local abundance of proliferative Ki-67+CD8+ T cells — a functional, spatially resolved immune-competence metric — was an independent predictor of improved survival that outperformed conventional cytogenetic risk stratification alone (37). Recent spatial transcriptomics studies integrating machine learning have identified exhaustion-like T-cell islands within the bone marrow that are spatially associated with malignant plasma cell niches and correlate with clinical risk stratification, confirming the prognostic value of spatially resolved immune profiling (46). Spatial signatures defined by cellular-neighborhood composition within a small radius (on the order of 10 μm) of plasma cells have similarly been shown to predict both disease duration and response to checkpoint-inhibitor therapy (37, 47), reinforcing the principle that local, rather than global, immune composition is the primary spatial determinant of clinical trajectory.
4.6 Post-treatment residual disease and dynamic immune reconstitution
Following induction and consolidation therapy, mIHC applied to serial bone marrow biopsies allows dynamic tracking of both residual tumor burden and immune reconstitution. Emerging resistance to CD38-targeted monoclonal antibody therapy (daratumumab) has been shown to be accompanied by a spatial redistribution of NK cells away from residual plasma-cell clusters and a concomitant increase in immunosuppressive macrophage density, detectable by mIHC/spatial profiling before overt clinical relapse manifests (48). This observation illustrates the emerging role of mIHC not merely as a static descriptor but as a longitudinal, minimally invasive monitoring tool capable of anticipating clinical relapse (elaborated further in Section 6.3).
4.7 Relapsed/refractory MM and CAR-T-associated microenvironment remodeling
In the RRMM setting, and particularly in the context of BCMA-directed CAR-T-cell therapy, the BMME has emerged as a principal determinant of both response durability and resistance. Single-cell and imaging-based profiling of patients relapsing after CAR-T therapy has identified pre-existing bone marrow niches enriched in fibroblasts and macrophages that physically shield residual plasma cells from CAR-T engagement, providing a spatial-structural explanation for otherwise unexplained treatment failure (49). Longitudinal tracking of bone marrow reconstitution following CAR-T infusion has further shown that durable responses correlate with restoration of a permissive immune landscape — characterized by reduced Treg density and increased persistence of effector CD8+ CAR-T cells — whereas relapse is associated with persistence of the immunosuppressive niche architecture established prior to therapy (50). Spatial mapping of CAR-T-cell distribution within the marrow has proven critical for understanding these relapse kinetics and for distinguishing genuine antigen-escape relapse from microenvironment-mediated functional exclusion of otherwise antigen-sensitive CAR-T cells (51).
4.8 Extramedullary disease: a distinct and more hostile immune microenvironment
Extramedullary disease represents the most aggressive manifestation of MM and is frequently resistant to immunotherapies that are otherwise effective against intramedullary disease. Direct comparison of the microenvironment of EMD versus intramedullary sites in patients receiving anti-BCMA CAR-T-cell therapy has revealed that EMD lesions are uniquely and significantly enriched in regulatory T cells and M2-polarized macrophages, forming a hyper-immunosuppressive barrier that physically excludes CAR-T-cell infiltration (52). Systematic review of the extramedullary immune microenvironment corroborates that spatial analysis is essential for explaining the inferior CAR-T infiltration and consequently inferior efficacy observed in EMD compared with intramedullary disease, and further underscores that EMD’s immunological barriers likely require combination strategies (e.g., checkpoint blockade or myeloid-targeting agents) rather than antigen-redirection therapy alone to overcome (53–55).Clinical data further demonstrate that extramedullary disease is associated with increased severity of CAR-T-related toxicities, likely reflecting the profoundly immunosuppressive and inflamed nature of the extramedullary microenvironment (56). Comprehensive reviews of CAR-T therapy for extramedullary MM have emphasized that while EMD should not be an absolute exclusion criterion for cellular therapy, the unique microenvironmental barriers in extramedullary sites require modified treatment strategies and combination approaches (57).
4.9 Synthesis: mIHC across the disease continuum as a companion diagnostic and efficacy predictor
Viewed as a continuum rather than as isolated case studies, the mIHC literature summarized above traces a coherent biological narrative: spatially organized immunosuppression is detectable from the earliest premalignant (MGUS/SMM) stage as metabolic-immune remodeling; consolidates into an overt immune-exclusion phenotype with checkpoint upregulation at NDMM; is dynamically remodeled — and potentially reversed — by effective therapy; re-emerges as a fibroblast/macrophage-shielded sanctuary in RRMM and post-CAR-T relapse; and reaches its most hostile configuration in EMD. This continuum framing directly motivates three clinical translation pathways that recur throughout the remainder of this review and are examined in detail in Section 6: (i) mIHC as a companion diagnostic for immunotherapy selection (e.g., LAG-3 or PD-1 expression mapping to guide checkpoint-inhibitor choice); (ii) mIHC as an efficacy predictor, not limited to CAR-T-cell therapy, but extending to checkpoint inhibitors, bispecific antibodies, and CD38-targeted monoclonal antibodies; and (iii) mIHC as a resistance monitor, capable of detecting spatial reorganization of the BMME that precedes clinically overt relapse across multiple treatment modalities. This disease-continuum synthesis, together with the multimodal integration paradigms (Section 5) and the discovery-to-clinical-implementation pathway (Section 7.5) that follow, is summarized graphically in Figure 3.
Figure 3
This section focuses specifically on currently realized application paradigms — concrete studies in which mIHC has been combined with another analytical modality to generate biological or clinical insight unattainable by either technology alone — reserving discussion of unresolved technical bottlenecks and future integration strategies for Section 7.
5 Integration of mIHC with complementary spatial and single-cell profiling technologies
5.1 mIHC + spatial transcriptomics: protein-level anchoring of transcriptomic signal
Spatial transcriptomics platforms such as Visium map whole-transcriptome expression but operate at supra-cellular resolution, capturing signal from mixed cell populations within each spot. mIHC serves as an essential single-cell-resolution anchor for validating and spatially refining these transcriptomic signals. Muiños-Lopez and colleagues combined Visium spatial transcriptomics with mIHC to characterize the bone marrow architecture of MM, using protein-level markers to validate spatial gradients of immune exhaustion gene expression identified transcriptomically and to confirm that these gradients corresponded to genuine spatial niches rather than technical artifacts of spot-level deconvolution (58). Extending this integration, Yip and colleagues profiled MM bone marrow trephine biopsies with combined spatial transcriptomics and immunohistochemical validation, demonstrating that integrating spatial proteomic markers allows reliable assignment of transcriptomically defined tumor subclones to specific cellular niches — an assignment that transcriptomics alone, at supra-cellular resolution, cannot achieve unambiguously (38, 59).
5.2 mIHC + single-cell rna sequencing: a discovery–validation loop
scRNA-seq defines transcriptional cell states with high resolution but, by requiring tissue dissociation, loses all spatial context. A recurring and productive paradigm in the MM microenvironment literature is a “discovery–validation loop,” in which scRNA-seq is first used to identify novel or previously uncharacterized T-cell or myeloid subsets based on transcriptional signatures, and mIHC is then applied to spatially localize these subsets within intact tissue sections, confirming their anatomical relationship to malignant plasma cells and their functional relevance within the in situ microenvironment (39). In a phase Ib clinical trial of oncolytic virus therapy in MM, Nawrocki and colleagues integrated single-cell immune profiling (scRNA-seq and flow cytometry) with mIHC and imaging mass cytometry performed on paired bone marrow biopsies, demonstrating concretely that while scRNA-seq quantified systemic T-cell activation status, only the imaging-based modalities could confirm the tissue-level distribution of activated T cells and their spatial proximity to residual tumor cells — a distinction with direct mechanistic implications for interpreting trial response (60).
5.3 mIHC + digital spatial profiling: morphology-guided deep proteomic sampling
The GeoMx DSP platform offers very high-sensitivity multiplex quantification from user-selected regions of interest, but — as discussed in Section 2.3 — lacks native single-cell resolution. A practical and increasingly common integration paradigm uses conventional fluorescent IHC staining (e.g., for CD138 plasma-cell marker and a pan-immune marker) to define morphologically and immunologically meaningful ROIs, which are then profiled in depth by DSP for hundreds of proteins simultaneously. This pairing has been used to reveal distinct immune niches in smoldering versus relapsed MM, maximizing both morphological precision (from the mIHC-guided ROI selection) and proteomic depth (from DSP’s high-plex readout) (26).
5.4 mIHC + artificial intelligence and deep learning
High-dimensional mIHC data at scale requires automated computational analysis, and AI-driven pipelines have moved beyond simple cell segmentation toward direct biological and clinical inference. Hagos and colleagues developed MoSaicNet, a graph neural network framework that models cell–cell spatial relationships as graphs, automatically identifying recurrent “immune neighborhoods” within myeloma bone marrow trephine biopsies that correlate independently with patient survival (10). Separately, algorithms have been developed to computationally align high-plex mIHC data with conventional H&E-stained sections of the same tissue, enabling the identification of image-based biomarkers directly from routine H&E slides without requiring specialized multiplex scanning hardware in every clinical laboratory — a strategy with direct relevance to lowering the accessibility barrier discussed in Section 7.4 (22). Taken together, these AI-augmented mIHC pipelines illustrate a genuine transition from purely descriptive spatial pathology toward predictive modeling of individualized clinical outcomes, a trajectory that (as discussed in Section 7.2) is currently constrained less by algorithmic sophistication than by the availability of standardized, cross-platform-generalizable training datasets specific to the MM BMME.
6 mIHC in treatment response evaluation and prognostic stratification
Building directly on the disease-continuum framework established in Section 4.9, this section consolidates the clinical translation dimension of mIHC — its emerging roles as a companion diagnostic, efficacy predictor, and resistance monitor — with explicit cross-reference back to the mechanistic findings of Section 4 rather than re-deriving them.
6.1 CAR-T-cell therapy and microenvironment-mediated resistance
CAR-T-cell therapy targeting BCMA is fundamentally limited by microenvironment-mediated resistance mechanisms that mIHC and imaging mass cytometry have been instrumental in characterizing. As detailed in Section 4.7, imaging-based profiling has shown that patients relapsing after CAR-T therapy frequently harbor pre-existing bone marrow niches enriched in fibroblasts and macrophages that physically shield residual plasma cells from CAR-T engagement (49). Longitudinal bone marrow reconstitution tracking has shown that durable CAR-T responses correlate with restoration of a permissive immune landscape (reduced Treg density, increased effector CD8+ CAR-T persistence), while relapse correlates with persistence of the pre-treatment immunosuppressive architecture (50). Spatial mapping of CAR-T-cell distribution within the marrow — not merely their peripheral blood expansion kinetics — has therefore become critical for mechanistically distinguishing antigen-loss relapse from microenvironment-mediated functional exclusion, with direct implications for selecting salvage strategies (e.g., a second CAR-T product with a different target versus a microenvironment-modulating combination approach) (51, 61, 62).
6.2 Disease stratification and risk prediction beyond CAR-T
mIHC-defined cellular neighborhoods and spatial biomarkers have repeatedly been shown to outperform standard cytogenetic and clinical risk scores. As introduced in Section 4.3, the combination of LAG-3 upregulation and increased CD8+ T-cell-to-plasma-cell distance predicts relapse in newly diagnosed and relapsed MM more accurately than cytogenetics alone (10). Similarly, as detailed in Section 4.5, proliferative CD8+ T-cell abundance within defined spatial neighborhoods serves as an independent prognostic biomarker in the high-risk t(4;14) cytogenetic subgroup, providing incremental prognostic value beyond conventional risk stratification (37). At the premalignant end of the spectrum, spatial and metabolic-immune biomarkers identified by digital spatial profiling in high-risk SMM (Section 4.2) offer a complementary, earlier risk-stratification opportunity that could in principle be integrated with the 2/20/20 or IMWG SMM risk models to refine early-intervention decision-making (45, 63). Collectively, this body of evidence establishes a new paradigm of mIHC-guided risk stratification that spans the full disease continuum rather than being confined to any single treatment context.
6.3 Dynamic efficacy monitoring and resistance detection
Serial bone marrow biopsies analyzed by mIHC allow dynamic, spatially resolved tracking of tumor burden and immune reconstitution that complements — rather than duplicates — flow-cytometric MRD assessment. As introduced in Section 4.6, emerging resistance to daratumumab is accompanied by a spatial redistribution of NK cells and an increase in immunosuppressive macrophage density that is detectable by mIHC before clinical relapse manifests biochemically or radiographically (48). This capacity for pre-emptive, spatially resolved resistance detection — applicable in principle to any BMME-modulating therapy, not solely CAR-T — constitutes one of the strongest arguments for eventual clinical adoption of serial mIHC alongside conventional MRD assessment, provided the turnaround-time and cost barriers discussed in Section 7.4 can be adequately addressed.
7 Technical bottlenecks impeding clinical translation and pathways to overcome them
Sections 5 and 6 above deliberately restricted their scope to realized multimodal integration paradigms and realized clinical-translation pathways. This section instead systematically catalogs the technical, economic, and pre-analytical bottlenecks that currently constrain routine clinical adoption of mIHC in MM BMME assessment, and outlines concrete breakthrough strategies for each — establishing a cross-reference relationship with Sections 2–6 rather than repeating their content.
7.1 Inherent technical limitations of current mIHC platforms
Even the most mature mIHC platforms carry intrinsic technical constraints that are frequently underemphasized in application-focused literature:
Spectral overlap and the plexing ceiling. Fluorescence-based platforms (Opal/TSA, t-CyCIF, MxIF) are fundamentally constrained by the finite number of spectrally resolvable fluorophores compatible with a given imaging system; beyond 7–9 simultaneously unmixed channels per acquisition, emission spectra increasingly overlap, degrading unmixing accuracy and introducing “bleed-through” artifacts that can generate false double-positive cells, particularly problematic when quantifying rare cell populations such as antigen-specific CAR-T cells within a dense plasma-cell background (18, 64).
Antibody cross-reactivity and validation burden. Because each additional marker in a cyclic panel must be validated not only in isolation but in combination with every other panel member (to exclude steric interference and cross-reactivity), panel validation burden scales non-linearly with plex number; this is compounded in bone marrow tissue where decalcification-induced epitope masking can alter antibody performance in ways not predictable from soft-tissue validation data (Section 2.2) (13).
Quantitative calibration and cross-tissue/cross-batch standardization. Unlike clinical chemistry assays with defined reference standards, mIHC lacks a widely adopted, platform-independent calibration standard; signal intensity is influenced by fixation time, decalcification protocol, section thickness, and scanner-specific gain settings, making direct quantitative comparison of biomarker intensity across different laboratories, batches, or even sequential sections from the same block difficult without rigorous internal reference controls (65, 66). The Society for Immunotherapy of Cancer (SITC) mIHC/mIF Task Force has explicitly identified assay validation, reference-standard use, and inter-laboratory reproducibility as the principal barriers to clinical-grade adoption, and has issued consensus recommendations (including the STORMI reporting standard) for minimum reporting elements — antibody clone, dilution, positive/negative control tissue, segmentation algorithm, and image-analysis pipeline — that this review recommends as the baseline standard for future MM BMME mIHC studies (65, 66).
Time-intensive cyclic workflows. As quantified in Table 2, cyclic staining–imaging–stripping protocols for a 6–8-plex Opal panel require 2–4 days from sectioning to analyzable image, an order of magnitude longer than single-plex IHC or flow cytometry — a constraint directly relevant to same-day or next-day clinical decision-making (elaborated in Section 7.4).
7.2 The AI data-silo problem
Section 5.4 highlighted the transition of AI-driven spatial analysis from descriptive pathology toward predictive modeling. This transition is currently constrained less by algorithmic sophistication than by data infrastructure: unlike radiology or digital H&E pathology, which benefit from large, publicly available, multi-institutional benchmark datasets, highly multiplexed spatial imaging data in MM BMME remains fragmented across proprietary institutional repositories, heterogeneous panel designs, and platform-specific file formats (e.g., Akoya’s.qptiff versus CODEX’s raw.tiff stacks versus GeoMx’s count matrices) (14, 67). Deep-learning models such as MoSaicNet trained on a single institution’s panel and staining protocol frequently exhibit substantial performance degradation when applied to external cohorts stained with a different antibody lot, panel composition, or imaging platform — a generalization failure mode increasingly termed “batch effect” in the spatial-omics AI literature (68). Overcoming this bottleneck will require (i) community-endorsed, FAIR (Findable, Accessible, Interoperable, Reusable)-compliant public repositories analogous to The Cancer Genome Atlas (TCGA) but specific to spatial proteomic imaging; (ii) federated learning approaches that allow model training across institutions without centralizing raw image data; and (iii) domain-adaptation algorithms explicitly designed to normalize for panel- and platform-specific staining variability before downstream biological inference.
7.3 Bone marrow specimen pre-processing: clot sections versus decalcified trephine biopsies
Section 2.2 introduced the pre-analytical challenges specific to bone marrow specimens; here we provide the operationally oriented comparison requested for experimental design. Two principal specimen types are available for mIHC in MM, and the choice between them involves a direct trade-off between antigen preservation and architectural context that has not been systematically discussed in prior mIHC reviews:
Bone marrow aspirate clot sections are prepared by allowing a small volume of aspirated marrow to clot in vitro, followed by standard formalin fixation and paraffin embedding without decalcification. Because no acid- or chelation-based demineralization step is required, clot sections preserve antigenicity substantially better than trephine biopsies, particularly for labile surface markers and phosphoepitopes, and are therefore the preferred specimen type when the primary goal is sensitive immune-cell-surface-marker phenotyping (e.g., checkpoint receptor panels: PD-1, LAG-3, TIM-3) (69, 70). Their principal limitations are a smaller and potentially non-representative sampling volume, variable and often lower cellularity, greater inter-clot heterogeneity, and a soft, friable consistency that increases sectioning artifacts and tissue loss across the repeated wash/strip cycles of high-plex mIHC (33, 71).
Decalcified trephine biopsy sections sample a larger, architecturally intact core of marrow, including the endosteal/trabecular bone surface, and are therefore indispensable for studies of spatial neighborhood structure, osteoclast/osteoblast interactions, and bone-remodeling biology (Section 4.1, 4.4) (30, 72). Their principal limitation is decalcification-induced antigen loss: EDTA-based (chelating) decalcification is comparatively gentle and is generally preferred for immunophenotyping-focused mIHC panels, whereas stronger acid-based decalcification (e.g., nitric or formic acid), while faster, more aggressively degrades epitopes — particularly CD138, CD20, and phosphorylated signaling proteins — and should be avoided when a multiplex immune panel is planned (30, 31). Trephine sections are also more brittle post-decalcification and prone to cracking or chipping during the extended cyclic-staining protocols required for high-plex panels (Section 2.2).
Practical recommendation. For studies prioritizing sensitive detection of labile immune-checkpoint or activation markers (e.g., CAR-T persistence phenotyping, exhaustion-marker panels), clot sections — when obtainable in sufficient quantity and cellularity — should be considered the preferred specimen; for studies requiring assessment of spatial neighborhood architecture, bone-remodeling interfaces, or retrospective analysis of archived diagnostic material (where only trephine blocks are typically banked), EDTA-decalcified trephine sections with extended antigen-retrieval optimization represent the more feasible choice. Concurrent aspirate and trephine sampling, standard practice in most hematology services, in principle allows both specimen types to be profiled in parallel from the same patient encounter, and this dual-specimen strategy — rarely exploited to date in the mIHC literature — represents an underused opportunity to combine the complementary strengths of both preparations (71, 73).
7.4 Economic and workflow barriers to clinical adoption
Beyond the purely technical limitations discussed above, the single largest practical barrier to routine clinical adoption of mIHC is its cost-effectiveness ratio and turnaround time (TAT) relative to established assays — a dimension largely absent from prior technical reviews of this field.
Cost structure. High-plex mIHC requires substantial capital investment (multispectral or high-content imaging scanners, typically in the range of hundreds of thousands of US dollars), premium reagent costs (TSA kits, barcoded-antibody conjugates, or metal-tagged antibodies, all priced well above standard IHC chromogens), and specialized bioinformatics infrastructure for image storage, spectral unmixing, and spatial statistical analysis — collectively placing per-case reagent-plus-analysis costs an order of magnitude above conventional single-plex IHC (Table 2) (25).
Turnaround time as a laboratory-developed test (LDT). For mIHC to be implemented as a clinical LDT under CLIA/CAP (or equivalent international) laboratory-accreditation frameworks, it must undergo rigorous analytical validation (reproducibility, sensitivity, specificity, reference intervals) analogous to companion-diagnostic IHC assays such as HER2 or PD-L1 testing (74, 75). Even after validation, the multi-day cyclic workflow (Table 2, Section 7.1) generates a TAT of 2–4 days for even a modest 6–8-plex panel — incompatible with time-sensitive clinical decisions such as pre-CAR-T-infusion microenvironment triage, where results are ideally available within 24–48 hours of biopsy.
Automated staining platforms as a mitigation strategy. Recent whole-slide automated multiplex immunofluorescence platforms substantially compress this workflow: fully automated staining instruments can now execute a 14-color panel with reduced hands-on time and improved inter-run reproducibility relative to manual cyclic staining (76), and automated high-throughput mIF workflows optimized specifically for translational and clinical laboratories have demonstrated reductions in both TAT and inter-operator variability compared with manual protocols (31, 77). Broader adoption of such automated platforms, combined with cloud-based or on-premises AI-assisted image analysis pipelines that eliminate manual gating/segmentation bottlenecks, represents the most immediately actionable pathway for narrowing the TAT and cost gap between mIHC and conventional IHC/flow cytometry sufficiently to support routine clinical use.
7.5 Synthesis: a roadmap from technical bottleneck to clinical breakthrough
Table 3 consolidates the bottlenecks discussed in this section alongside concrete, currently available or near-term mitigation strategies, providing an actionable roadmap rather than a purely descriptive limitations list.
Table 3
| Bottleneck category | Specific limitation | Breakthrough pathway |
|---|---|---|
| Spectral/analytical | Spectral overlap limits plexing ceiling (Opal/TSA); bleed-through artifacts | Migration to DNA-barcode (CODEX/PhenoCycler) or metal-isotope (IMC/MIBI) modalities for higher-plex applications; improved unmixing algorithms |
| Standardization | No universal quantitative calibration standard; inter-lab/inter-batch variability | SITC/STORMI consensus reporting standards; inclusion of internal reference-control tissue on every run |
| AI/data infrastructure | Fragmented, platform-specific, non-interoperable datasets; poor cross-cohort generalization | FAIR-compliant public spatial-imaging repositories; federated learning; domain adaptation |
| Pre-analytical (specimen) | Decalcification-induced antigen loss (trephine) vs. limited representativeness (clot) | Dual concurrent aspirate-clot + trephine sampling; EDTA (chelating) decalcification with extended antigen retrieval |
| Economic/workflow | High capital/reagent cost; 2–4 day TAT incompatible with urgent clinical decisions | Fully automated staining platforms; cloud/on-premises AI-assisted analysis; tiered panel design (screening panel → deep panel) |
| Regulatory | No FDA/NMPA-approved mIHC companion diagnostic in MM to date | Analytical and clinical validation pathways modeled on established IHC companion diagnostics (HER2, PD-L1); multicenter proficiency testing |
Technical and translational bottlenecks in mIHC for MM BMME analysis, and corresponding breakthrough pathways.
Taken together, the bottlenecks and pathways summarized in Table 3 indicate that the transition of mIHC from a research tool to a routine clinical assay in MM is primarily rate-limited not by fundamental technical feasibility — which has been amply demonstrated across the disease continuum in Section 4 — but by standardization, data infrastructure, and health-economic factors that are, in principle, addressable through coordinated community effort over the coming 3–5 years.
8 Conclusion and future perspectives
Multiplex immunohistochemistry has evolved from a niche research technique into an indispensable tool for dissecting the spatial architecture of the multiple myeloma bone marrow microenvironment. By correctly classifying platforms according to their detection readout modality — fluorescence spectral unmixing/TSA cyclic staining, DNA-barcode cyclic hybridization, metal-isotope mass spectrometric imaging, and regional-photolysis digital spatial profiling — and by resolving several long-standing technical misconceptions regarding platform lineage and elution chemistry (Section 2), this review has sought to establish an accurate technical foundation upon which the biological and clinical literature can be more rigorously interpreted. Organizing the accumulated mIHC evidence along the natural MGUS → SMM → NDMM → post-treatment → RRMM → EMD disease continuum (Section 4) reveals a coherent narrative of progressively intensifying, spatially organized immunosuppression — from early metabolic-immune remodeling at the premalignant stage, through overt T-cell exclusion and checkpoint upregulation in active disease, to fibroblast/macrophage-shielded sanctuaries that underlie CAR-T resistance and the hyper-immunosuppressive, immune-desert phenotype of extramedullary disease.
Looking forward, three developments will likely determine the pace at which mIHC transitions from research tool to routine clinical assay in MM. First, continued platform miniaturization and automation (Section 7.4) should progressively narrow the cost and turnaround-time gap that currently separates mIHC from flow cytometry and conventional IHC, particularly for time-sensitive applications such as pre-CAR-T microenvironment triage. Second, community-wide adoption of SITC/STORMI reporting standards and the development of FAIR-compliant, cross-platform-interoperable spatial imaging data repositories (Section 7.2) will be essential prerequisites for training generalizable AI models and for enabling multicenter validation studies — the mandatory final step before any mIHC-derived biomarker can be considered for regulatory approval as a companion diagnostic. Third, as same-slide and same-section multimodal integration matures (Section 5), mIHC is likely to be increasingly deployed not as a standalone assay but as one co-equal layer within an integrated spatial multi-omics workflow that combines protein, transcript, and eventually metabolite-level information from a single tissue section — a trajectory that would allow the discovery-stage insights synthesized in this review to be translated into prospectively validated, clinically actionable biomarkers of immunotherapy response, resistance, and relapse in multiple myeloma.
Statements
Author contributions
DZ: Writing – original draft, Writing – review & editing. XG: Writing – original draft, Writing – review & editing. CW: Writing – original draft. LB: Writing – original draft, Writing – review & editing.
Funding
The author(s) declared that financial support was not received for this work and/or its publication.
Acknowledgments
The authors thank the Department of Hematology, China-Japan Union Hospital of Jilin University, for institutional support.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
CowanAJAllenCBaracABasaleemHBensenorICuradoMPet al. Global burden of multiple myeloma: a systematic analysis for the global burden of disease study 2016. JAMA Oncol. (2018) 4:1221–7. doi: 10.1200/jco.2018.36.15_suppl.e20023
2
RajkumarSV. Multiple myeloma: 2018 update on diagnosis, risk‐stratification, and management. Am J Hematol. (2018) 93:981–1114. doi: 10.1002/ajh.25117
3
SzlasaWDybkoJ. Current status of bispecific antibodies and CAR-T therapies in multiple myeloma. Int Immunopharmacol. (2024) 134:112043. doi: 10.1016/j.intimp.2024.112043
4
de JongMMEKellermayerZPapazianNTahriSHofste op BruininkDHoogenboezemRet al. The multiple myeloma microenvironment is defined by an inflammatory stromal cell landscape. Nat Immunol. (2021) 22:769–80. doi: 10.1038/s41590-021-00931-3
5
García-OrtizARodríguez-GarcíaYEncinasJMaroto-MartínECastellanoETeixidóJet al. The role of tumor microenvironment in multiple myeloma development and progression. Cancers (Basel). (2021) 13:217. doi: 10.3390/cancers13020217
6
BaiJNishimuraNKawanoY. Advances in immune microenvironment profiling during multiple myeloma progression and therapy. Int J Hematol. (2026) 124:38–47. doi: 10.1007/s12185-025-04110-0
7
GuadagnoLSchüttJBrinkertKSchenkTBrioliA. The role of the bone marrow microenvironment in disease progression and drug resistance in multiple myeloma in the era of novel agents. Leuk Lymphoma. (2026) 67:40–54. doi: 10.1080/10428194.2025.2575438
8
LedergorGWeinerAZadaMWangSYCohenYCGattMEet al. Single cell dissection of plasma cell heterogeneity in symptomatic and asymptomatic myeloma. Nat Med. (2018) 24:1867–76. doi: 10.1038/s41591-018-0269-2
9
ZhaoZZhaoZLinZFanLXiahouZDongYet al. Decoding multiple myeloma: single-cell insights into tumor heterogeneity, immune dynamics, and disease progression. Front Immunol. (2025) 16:1584350. doi: 10.3389/fimmu.2025.1584350
10
HagosYBLecatCSYPatelDMikolajczakACastilloSPLyonEJet al. Deep learning enables spatial mapping of the mosaic microenvironment of myeloma bone marrow trephine biopsies. Cancer Res. (2024) 84:493–508. doi: 10.1158/0008-5472.can-22-2654
11
TanWCCNerurkarSNCaiHYNgHHMWuDWeeYTFet al. Overview of multiplex immunohistochemistry/immunofluorescence techniques in the era of cancer immunotherapy. Cancer Commun (Lond). (2020) 40:135–53. doi: 10.1002/cac2.12023
12
ShengWZhangCMohiuddinTMAl-RaweMZeppernickFFalconeFHet al. Multiplex immunofluorescence: a powerful tool in cancer immunotherapy. Int J Mol Sci. (2023) 24:3086. doi: 10.3390/ijms24043086
13
ParraERFrancisco-CruzAWistubaII. State-of-the-art of profiling immune contexture in the era of multiplexed staining and digital analysis to study paraffin tumor tissues. Cancers (Basel). (2019) 11:247. doi: 10.3390/cancers11020247
14
ZidaneMMakkyABruhnsMRochwargerABabaeiSClaassenMet al. A review on deep learning applications in highly multiplexed tissue imaging data analysis. Front Bioinform. (2023) 3:1159381. doi: 10.3389/fbinf.2023.1159381
15
GerdesMJSevinskyCJSoodAAdakSBelloMOBordwellAet al. Highly multiplexed single-cell analysis of formalin-fixed, paraffin-embedded cancer tissue. Proc Natl Acad Sci USA. (2013) 110:11982–7. doi: 10.1073/pnas.1300136110
16
HernandezSRojasFLaberianoCLazcanoRWistubaIParraER. Multiplex immunofluorescence tyramide signal amplification for immune cell profiling of paraffin-embedded tumor tissues. Front Mol Biosci. (2021) 8:667067. doi: 10.3389/fmolb.2021.667067
17
ShengWMohiuddinTMZhangCAl-RaweMKonradLWagnerSet al. A customizable tyramide signal amplification-based multiplex immunofluorescence protocol for FFPE tissues. Curr Issues Mol Biol. (2026) 48:439. doi: 10.3390/cimb48050439
18
AkturkGParraERGjiniELakoALeeJJNeubergDet al. Multiplex tissue imaging harmonization: a multicenter experience from CIMAC-CIDC immuno-oncology biomarkers network. Clin Cancer Res. (2021) 27:5072–83. doi: 10.1158/1078-0432.ccr-21-2051
19
GoltsevYSamusikNKennedy-DarlingJBhateSHaleMVazquezGet al. Deep profiling of mouse splenic architecture with CODEX multiplexed imaging. Cell. (2018) 174:968–981.e15. doi: 10.2139/ssrn.3155542
20
HickeyJWTanYNolanGPGoltsevY. Strategies for accurate cell type identification in CODEX multiplexed imaging data. Front Immunol. (2021) 12:727626. doi: 10.3389/fimmu.2021.727626
21
LiuCCMcCaffreyEFGreenwaldNFSoonERisomTVijayaragavanKet al. Multiplexed ion beam imaging: insights into pathobiology. Annu Rev Pathol. (2022) 17:403–23. doi: 10.1146/annurev-pathmechdis-030321-091459
22
LinJRIzarBWangSYappCMeiSShahPMet al. Highly multiplexed immunofluorescence imaging of human tissues and tumors using t-CyCIF and conventional optical microscopes. Elife. (2018) 7:e31657. doi: 10.7554/elife.31657
23
AngeloMBendallSCFinckRHaleMBHitzmanCBorowskyADet al. Multiplexed ion beam imaging of human breast tumors. Nat Med. (2014) 20:436–42. doi: 10.1038/nm.3488
24
GiesenCWangHAOSchapiroDZivanovicNJacobsAHattendorfBet al. Highly multiplexed imaging of tumor tissues with subcellular resolution by mass cytometry. Nat Methods. (2014) 11:417–22. doi: 10.1038/nmeth.2869
25
DevineRDBehbehaniGK. Mass cytometry, imaging mass cytometry, and multiplexed ion beam imaging use in a clinical setting. Clin Lab Med. (2021) 41:297–308. doi: 10.1016/j.cll.2021.03.008
26
KoldejRMRitchieDS. High multiplex analysis of the immune microenvironment in bone marrow trephine samples using GeoMX™ digital spatial profiling. Immunooncol Technol. (2020) 5:1–9. doi: 10.1016/j.iotech.2020.02.001
27
HengSLeeTChoiSALeeHKimSKPhiJH. An evaluation of MACSima and PhenoCycler-Fusion for spatial image analysis in a medulloblastoma xenograft model. Microsc Res Tech. (2026) 89:959–71. doi: 10.1002/jemt.70125
28
BaresAJDe GrandAManesseM. Abstract 3873: High-multiplex automated staining and scanning workflow with Ultivue InSituPlex technology and the Olympus SLIDEVIEW VS200 slide scanner. Cancer Res. (2020) 80:3873. doi: 10.1158/1538-7445.am2020-3873
29
YeungCCJonesDCWoolstonDWSeatonBDonatoELLinMet al. Spatial proteomics and transcriptomics characterization of tissue and multiple cancer types including decalcified marrow. Cancer biomark. (2025) 42:18758592241308757. doi: 10.1177/18758592241308757
30
WilkinsBSClarkDM. Making the most of bone marrow trephine biopsy. Histopathology. (2009) 55:631–40. doi: 10.1111/j.1365-2559.2009.03353.x
31
ZellFGellrichKGründerASchulzeJMüllerAEblePet al. From image to insight: optimized multiplex staining panel for formalin-fixed, paraffin-embedded mouse bone marrow enables spatial profiling of the hematopoietic niche. Exp Hematol. (2026) 158:105419. doi: 10.1016/j.exphem.2026.105419
32
AfkhamiMVergara-LluriMBrynesRKSiddiqiIN. Peripheral blood smears, bone marrow aspiration, trephine and clot biopsies: methods and protocols. Methods Mol Biol. (2014) 1180:257–69. doi: 10.1007/978-1-4939-1050-2_14
33
KellerALDennisKAOhlstromDJParzychSEWalkerZJNovakAJet al. Multiple myeloma cells resistant to T-cell therapies exhibit a CD45+ immunoevasive phenotype. Cancer Immunol Res. (2026) 14:1307–21. doi: 10.1158/2326-6066.cir-25-1068
34
WangJTuCZhangHHuoYMenuELiuJ. Single-cell analysis at the protein level delineates intracellular signaling dynamic during hematopoiesis. BMC Biol. (2021) 19:201. doi: 10.1186/s12915-021-01138-6
35
ZhangTWardenARLiYDingX. Progress and applications of mass cytometry in sketching immune landscapes. Clin Transl Med. (2020) 10:e206. doi: 10.1002/ctm2.206
36
OhlstromDJMichaudMEBakhtiariMVieira Dos SantosJPilcherWCStaubAet al. Spatial multi-omics of multiple myeloma uncovers niche-dependent pro-myeloma and immunosuppressive signaling in the bone marrow and extramedullary lesions. In: BiorxivCold Spring Harbor, NY: Cold Spring Harbor Laboratory (2026).
37
SimoniYChngMHYLiSFehlingsMNewellEW. Mass cytometry: a powerful tool for dissecting the immune landscape. Curr Opin Immunol. (2018) 51:187–96. doi: 10.1016/j.coi.2018.03.023
38
LiJYangYWangWXuJSunYJiangJet al. Single-cell atlas of the immune microenvironment reveals macrophage reprogramming and the potential dual macrophage-targeted strategy in multiple myeloma. Br J Haematol. (2023) 201:917–34. doi: 10.1111/bjh.18708
39
BhowmickKvon SuskilMAl-OdatOSElbezantiWOJonnalagaddaSCBudak-AlpdoganTet al. Pathways to therapy resistance: the sheltering effect of the bone marrow microenvironment to multiple myeloma cells. Heliyon. (2024) 10:e33091. doi: 10.1016/j.heliyon.2024.e33091
40
DangMBansalHAcevedo-CaladoMJQinLTanWMoreno RuedaLYet al. Single cell analysis of the tumor microenvironment landscape across the disease spectrum of multiple myeloma. Blood (2026).
41
SembaTIshimotoT. Spatial analysis by current multiplexed imaging technologies for the molecular characterisation of cancer tissues. Br J Cancer. (2024) 131:1737–47. doi: 10.1038/s41416-024-02882-6
42
SchinkeCPoosAMBauerMJohnLJohnsonSDeshpandeSet al. Characterizing the role of the immune microenvironment in multiple myeloma progression at a single-cell level. Blood Adv (2022) 6(22):5873–5883. doi: 10.1182/bloodadvances.2022007217
43
RosethIAHatscherLSchillerCJohnstuenHSSSlørdahlTSHovHet al. Multiplexed imaging reveals immune-metabolic niches in multiple myeloma linked to progression and bone disease. Blood Cancer Discov. (2026) 7:460–78. doi: 10.1158/2643-3230.bcd-25-0334
44
GuptaBYangGKeyM. Unlocking the tumor microenvironment: innovations in multiplex immunohistochemistry. Cells. (2025) 14:1819. doi: 10.3390/cells14221819
45
WangXXiongXXuCHanHGuanAGaoYet al. Single-cell analysis reveals inflammatory–immunosuppressive niches in daratumumab-resistant primary AL amyloidosis. In: MedrxivCold Spring Harbor, NY: Cold Spring Harbor Laboratory (2026). p. 2026.03.28.26349317.
46
LiuFLiGZhengYLiuYLiuK. Multiplex imaging analysis of the tumor immune microenvironment for guiding precision immunotherapy. Front Immunol. (2025) 16:1617906. doi: 10.3389/fimmu.2025.1617906
47
IannozziNTGiulianiNStortiP. Deciphering the bone marrow microenvironment's role in multiple myeloma immunotherapy resistance. Front Immunol. (2025) 16:1613265. doi: 10.3389/fimmu.2025.1613265
48
RadeMGriebNWeissRSiaJFischerLBornPet al. Single-cell multiomic dissection of response and resistance to chimeric antigen receptor T cells against BCMA in relapsed multiple myeloma. Nat Cancer. (2024) 5:1318–33. doi: 10.1038/s43018-024-00763-8
49
RadeMFandreiDKreuzMSeiffertSGrahnertAFriedrichMet al. A longitudinal single-cell atlas to predict outcome and toxicity after BCMA-directed CAR T cell therapy in multiple myeloma. Cancer Cell. (2026) 44:586–603.e9. doi: 10.1016/j.ccell.2025.10.014
50
SaezGKhusialRHamediKArreolaNKhuuHKisselH. Overcoming microenvironment-driven resistance to CAR-T therapy in multiple myeloma. Lymphatics. (2026) 4:15. doi: 10.3390/lymphatics4010015
51
ChenWChengHQiKZhuFXiaFZhuLet al. Anti-BCMA/GPRC5D CAR T cells in patients with relapsed or refractory multiple myeloma who have extraosseous extramedullary disease. Blood (2026) 148(7):831–40. doi: 10.1182/blood.2026033506
52
KumarSRichterJUsmaniSZCohenYCYeJCMateosMVet al. Extramedullary disease-achilles heel in myeloma? Am J Hematol. (2026) 101:521–36. doi: 10.1002/ajh.70138
53
CenzanoICóceraMLopez-PerezARCampos-DopazoLRuizJSanchoIet al. Single-cell profiling reveals RAB13(+) endothelial cells and profibrotic mesenchymal cells in aged human bone marrow. Aging Cell. (2026) 25:e70475. doi: 10.1111/acel.70475
54
DesantisVAndrianoADükingTHartwigOIngravalloGBiondoMet al. Spatial imaging unlocks the potential of charting multiple myeloma and extramedullary disease. J Hematol Oncol. (2025) 18:47. doi: 10.1186/s13045-025-01699-x
55
LiYLLiMJLiJJChenDLiCYQiuLet al. Efficacy and safety of BCMA-directed CAR T-cell therapy in extramedullary relapsed or refractory multiple myeloma: a meta-analysis. Front Immunol. (2026) 17:1792558. doi: 10.3389/fimmu.2026.1792558
56
Cordas Dos SantosDFosterKHeilpern-MalloryDSchroederSKonishiYSilverioMTet al. Spatial proteomics of the bone marrow reveals distinct tumor–immune niches in smoldering and relapsed myeloma and their remodeling in response to bispecific antibody and CAR-T therapy. Blood. (2025) 146:3921. doi: 10.1182/blood-2025-3921
57
GramegnaDMondelliPPappagalloSAGarganoGVeglianteMCQuintoAMet al. Cutting-edge technologies to decode tumor microenvironment in multiple myeloma. Hematol Oncol. (2026) 44:e70171. doi: 10.1002/hon.70171
58
NawrockiSTOleaJVilla CeliCDadrastoussiHWuKTsao-WeiDet al. Comprehensive single-cell immune profiling defines the patient multiple myeloma microenvironment following oncolytic virus therapy in a phase Ib trial. Clin Cancer Res. (2023) 29:5087–103. doi: 10.1158/1078-0432.ccr-23-0229
59
Muiños-LopezELopez-PerezARSudupeLVilas-ZornozaASarvideSRipalda-CemborainPet al. Characterization of the bone marrow architecture of multiple myeloma using spatial transcriptomics. Commun Biol. (2025) 8:1620. doi: 10.1038/s42003-025-08975-z
60
MateosMVKumarSDimopoulosMAGonzález-CalleVKastritisEHajekRet al. International Myeloma Working Group risk stratification model for smoldering multiple myeloma (SMM). Blood Cancer J. (2020) 10:102. doi: 10.1038/s41408-020-00366-3
61
ToomesCEJBestOGHollenbergTTurnerRBonderCSMcClureBJ. Advances in modeling multiple myeloma within the bone marrow tumor microenvironment for exploration of current and emerging therapies. Cancers (Basel). (2026) 18:2050. doi: 10.3390/cancers18132050
62
YaoHChengLChenDZhangQQiuLRenSHet al. Role of the bone marrow microenvironment in multiple myeloma treatment using CAR-T therapy. Expert Rev Anticancer Ther. (2023) 23:807–15. doi: 10.1080/14737140.2023.2229029
63
ShakyaRNguyenTHWaterhouseNKhannaR. Immune contexture analysis in immuno-oncology: applications and challenges of multiplex fluorescent immunohistochemistry. Clin Transl Immunol. (2020) 9:e1183. doi: 10.1002/cti2.1183
64
TaubeJMSunshineJCAngeloMAkturkGEminizerMEngleLLet al. Society for Immunotherapy of Cancer: updates and best practices for multiplex immunohistochemistry (IHC) and immunofluorescence (IF) image analysis and data sharing. J Immunother Cancer. (2025) 13:e008875. doi: 10.1136/jitc-2024-008875
65
Ben-UriRBen ShabatLShainsheinDBar-TalOBussiYMaimonNet al. High-dimensional imaging using combinatorial channel multiplexing and deep learning. Nat Biotechnol. (2026) 44:233–46. doi: 10.1038/s41587-025-02585-0
66
SaterSBifulcoCBRodriguez-CanalesJYeongJAkturkGAngeloMet al. Society for immunotherapy of cancer: standards for reporting of multiplex immunohistochemistry/immunofluorescence assays (STORMI). J Immunother Cancer. (2025) 13:e012280. doi: 10.1136/jitc-2025-012280
67
EmeryJFLeMKLevyJVaickusLLiuX. Machine learning, deep learning, and artificial intelligence as applied to the field of cytopathology: a comprehensive review. J Am Soc Cytopathol. (2026) 15:4–22. doi: 10.1016/j.jasc.2025.07.004
68
GargPKaurHTayalIHadaAS. Bone marrow clot section a useful tool for diagnosis of haematological diseases- a case series. J Clin Diagn Res. (2021) 15(6):EC01–EC05. doi: 10.7860/jcdr/2021/49056:15028
69
CantadoriLOGaiollaRDNiero-MeloLOliveiraCC. Bone marrow aspirate clot: a useful technique in diagnosis and follow-up of hematological disorders. Case Rep Hematol. (2019) 2019:7590948. doi: 10.1155/2019/7590948
70
SharmaPPuriVKotruMSikkaMSharmaS. Utility of simultaneous assessment of bone marrow aspirates and trephine biopsy sections in various haematological disorders. Iraqi J Hematol. (2018) 7:26–32. doi: 10.4103/ijh.ijh_33_17
71
KremerMQuintanilla-MartínezLNährigJvon SchillingCFendF. Immunohistochemistry in bone marrow pathology: a useful adjunct for morphologic diagnosis. Virchows Arch. (2005) 447:920–37. doi: 10.1007/s00428-005-0070-8
72
RileyRSWilliamsDRossMZhaoSChesneyAClarkBDet al. Bone marrow aspirate and biopsy: a pathologist's perspective. II. interpretation of the bone marrow aspirate and biopsy. J Clin Lab Anal. (2009) 23:259–307. doi: 10.1002/jcla.20305
73
BartleyANWashingtonMKIsmailaNAjaniJA. HER2 testing and clinical decision making in gastroesophageal adenocarcinoma: guideline from the College of American Pathologists, American Society for Clinical Pathology, and the American Society of Clinical Oncology. J Clin Oncol. (2017) 35:446–64. doi: 10.1200/jop.2016.018929
74
LaiJCavagniniKSSmithMKatembohKSunshineJCTaubeJMet al. Upping the "plex": whole slide, automated 14-color multiplex immunofluorescence staining of the tumor microenvironment in paraffin-embedded tissue. Lab Invest. (2026) 106:106130. doi: 10.1016/j.labinv.2026.106130
75
YeongJTanTChowZLChengQLeeBSeetAet al. Multiplex immunohistochemistry/immunofluorescence (mIHC/IF) for PD-L1 testing in triple-negative breast cancer: a translational assay compared with conventional IHC. J Clin Pathol. (2020) 73:557–62. doi: 10.1136/jclinpath-2019-206252
76
HwangKVeithADuroLWoodDChatterjeeGCajigasYet al. High-throughput automated multiplex immunofluorescence assays for translational research. J Vis Exp. (2025) 220(220):e67584. doi: 10.3791/67584
77
SuraceMDaCostaKHuntleyAZhaoWBagnallCBrownCet al. Automated multiplex immunofluorescence panel for immuno-oncology studies on formalin-fixed carcinoma tissue specimens. J Vis Exp. (2019) 143(143):e58390. doi: 10.3791/58390
Summary
Keywords
bone marrow microenvironment, CAR-T cell therapy, immune evasion, multiple myeloma, multiplex immunohistochemistry, spatial biology
Citation
Zhou D, Guo X, Wang C and Bi L (2026) Multiplex immunohistochemistry in multiple myeloma: principles, spatial profiling applications, and emerging frontiers in immuno-oncology. Front. Oncol. 16:1898260. doi: 10.3389/fonc.2026.1898260
Received
02 June 2026
Revised
09 August 2026
Accepted
16 October 2026
Published
02 November 2026
Volume
16 - 2026
Edited by
Alessandro Isidori, AORMN Hospital, Italy
Reviewed by
Yunhui Xiang, Sichuan International Travel and Healthcare Center (Chengdu Customs District Port Clinic), China
Naseel Moursy, Alfaisal University, Saudi Arabia
Updates
Copyright
© 2026 Zhou, Guo, Wang and Bi.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Lintao Bi, bilt@jlu.edu.cn
†These authors have contributed equally to this work and share first authorship
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.