<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Pediatr.</journal-id>
<journal-title>Frontiers in Pediatrics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Pediatr.</abbrev-journal-title>
<issn pub-type="epub">2296-2360</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fped.2024.1313781</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Pediatrics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>The novel LESS (low-cost entrainment syringe system) O<sub>2</sub> blender for use in modified bubble CPAP circuits: a clinical study of safety</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Wu</surname><given-names>Andrew G.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/2538744/overview"/><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/visualization/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Luch</surname><given-names>Sreyleak</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Slusher</surname><given-names>Tina M.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/504694/overview" /><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Fischer</surname><given-names>Gwenyth A.</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Lunos</surname><given-names>Scott A.</given-names></name>
<xref ref-type="aff" rid="aff6"><sup>6</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Bjorklund</surname><given-names>Ashley R.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/513814/overview" /></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><institution>Division of Critical Care Medicine, Boston Children&#x2019;s Hospital</institution>, <addr-line>Boston, MA</addr-line>, <country>United States</country></aff>
<aff id="aff2"><label><sup>2</sup></label><institution>Department of Pediatrics, Division of Pediatric Critical Care, Hennepin Healthcare</institution>, <addr-line>Minneapolis, MN</addr-line>, <country>United States</country></aff>
<aff id="aff3"><label><sup>3</sup></label><institution>Department of Pediatrics, Chenla Children&#x2019;s Healthcare</institution>, <addr-line>Kratie</addr-line>, <country>Cambodia</country></aff>
<aff id="aff4"><label><sup>4</sup></label><institution>Department of Pediatrics Global Pediatrics, University of Minnesota</institution>, <addr-line>Minneapolis, MN</addr-line>, <country>United States</country></aff>
<aff id="aff5"><label><sup>5</sup></label><institution>Department of Pediatrics, Division of Pediatric Critical Care, University of Minnesota</institution>, <addr-line>Minneapolis, MN</addr-line>, <country>United States</country></aff>
<aff id="aff6"><label><sup>6</sup></label><institution>Biostatistical Design and Analysis Center, University of Minnesota</institution>, <addr-line>Minneapolis, MN</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Nora Bruns, Essen University Hospital, Germany</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Janina Soler Wenglein, Bielefeld University, Germany</p>
<p>Osayame Ekhaguere, Indiana University Hospital, United States</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Andrew G. Wu <email>andrewwu@umn.edu</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>12</day><month>02</month><year>2024</year></pub-date>
<pub-date pub-type="collection"><year>2024</year></pub-date>
<volume>12</volume><elocation-id>1313781</elocation-id>
<history>
<date date-type="received"><day>10</day><month>10</month><year>2023</year></date>
<date date-type="accepted"><day>25</day><month>01</month><year>2024</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2024 Wu, Luch, Slusher, Fischer, Lunos and Bjorklund.</copyright-statement>
<copyright-year>2024</copyright-year><copyright-holder>Wu, Luch, Slusher, Fischer, Lunos and Bjorklund</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec><title>Background</title>
<p>Bubble continuous positive airway pressure (bCPAP) is used in resource-limited settings for children with respiratory distress. Low-cost modifications of bCPAP use 100&#x0025; oxygen and may cause morbidity from oxygen toxicity. We sought to test a novel constructible low-cost entrainment syringe system (LESS) oxygen blender with low-cost modified bCPAP in a relevant clinical setting.</p>
</sec>
<sec><title>Methods</title>
<p>We conducted a clinical trial evaluating safety of the LESS O<sub>2</sub> blender among hospitalized children under five years old in rural Cambodia evaluating the rate of clinical failure within one hour of initiation of the LESS O<sub>2</sub> blender and monitoring for any other blender-related complications.</p>
</sec>
<sec><title>Findings</title>
<p>Thirty-two patients were included. The primary outcome (clinical failure) occurred in one patient (3.1&#x0025;, 95&#x0025; CI&#x2009;&#x003D;&#x2009;0.1&#x2013;16.2&#x0025;). Clinical failure was defined as intubation, death, transfer to another hospital, or two of the following: oxygen saturation &#x003C;85&#x0025; after 30&#x2005;min of treatment; new signs of respiratory distress; or partial pressure of carbon dioxide &#x2265;60&#x2005;mmHg and pH &#x003C;7.2 on a capillary blood gas. Secondary outcomes included average generated FiO<sub>2</sub>&#x0027;s with blender use, which were 59&#x0025; and 52&#x0025; when a 5&#x2005;mm entrainment was used vs. a 10&#x2005;mm entrainment port with 5&#x2013;7&#x2005;cm H<sub>2</sub>O of CPAP and 1&#x2013;7&#x2005;L/min (LPM) of flow; and adverse events including loss of CPAP bubbling (64&#x0025; of all adverse events), frequency of repair or adjustment (44&#x0025;), replacement (25&#x0025;), and median time of respiratory support (44&#x2005;h).</p>
</sec>
<sec><title>Interpretation</title>
<p>Overall the LESS O<sub>2</sub> blender was safe for clinical use. The design could be modified for improved performance including less repair needs and improved nasal interface, which requires modification for the blender to function more consistently.</p>
</sec>
</abstract>
<kwd-group>
<kwd>pneumonia</kwd>
<kwd>bubble CPAP</kwd>
<kwd>respiratory support</kwd>
<kwd>hyperoxia</kwd>
<kwd>global health</kwd>
<kwd>pediatrics</kwd>
<kwd>medical device</kwd>
</kwd-group>
<contract-num rid="cn001">UL1TR002494</contract-num>
<contract-sponsor id="cn001">National Institutes of Health&#x2019;s National Center for Advancing Translational Sciences</contract-sponsor>
<counts>
<fig-count count="4"/>
<table-count count="3"/><equation-count count="0"/><ref-count count="34"/><page-count count="0"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Neonatology</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro"><title>Introduction</title>
<p>Lower respiratory tract infections (LRTIs) continue to be the leading cause of death among children under five years old worldwide (<xref ref-type="bibr" rid="B1">1</xref>&#x2013;<xref ref-type="bibr" rid="B4">4</xref>). This burden is particularly significant in low-middle income countries (LMICs) in Sub-Saharan Africa and Southeast Asia (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B4">4</xref>). Respiratory support is key in decreasing mortality from LRTIs. Unfortunately, many respiratory support modalities, such as ventilators or non-invasive respiratory support devices, have limited availability in LMICs due to high cost, lack of trained staff for device maintenance and repair, reliance on electricity, and lack of specialized materials and parts (<xref ref-type="bibr" rid="B5">5</xref>).</p>
<p>Continuous positive airway pressure (CPAP), a form of respiratory support, provides constant airway pressure stenting open alveoli at the end of exhalation, reducing work of breathing and improving oxygenation (<xref ref-type="bibr" rid="B6">6</xref>). Commercial CPAP devices cost thousands of dollars and require electricity. In the 1970&#x0027;s, an alternative form of CPAP, called bubble CPAP (bCPAP), was invented for neonatal use (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B8">8</xref>). BCPAP uses an expiratory limb submerged in a water column which generates CPAP that approximates the pressure at the air water interface assuming minimal resistive pressure losses in the breathing circuit (<xref ref-type="bibr" rid="B9">9</xref>, <xref ref-type="bibr" rid="B10">10</xref>). Unlike commercial CPAP, bCPAP circuits can be run without electricity using compressed air or oxygen. In multiple studies, bCPAP has been shown to successfully provide respiratory support and decrease neonatal mortality in both high-income countries (HIC) and LMICs (<xref ref-type="bibr" rid="B11">11</xref>&#x2013;<xref ref-type="bibr" rid="B17">17</xref>). To address the burden of LRTI in resource-limited areas, a modified low-cost version of bCPAP has been developed using basic supplies readily found in hospitals in LMIC&#x0027;s (<xref ref-type="bibr" rid="B18">18</xref>). Promoted by the World Health Organization (WHO), this version has allowed hospitals to provide effective and safe respiratory support to young children at minimal cost [approximately 5 US dollars (USD) excluding oxygen costs] when the alternative is direct oxygen flow by nasal cannula without pressure support or spending thousands of dollars on an industry-level product (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>).</p>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>Bubble CPAP set-up. Reprinted with permission from the World Health Organization. A modified version of this circuit for older children was safety tested by Bjorklund, et al. that uses ear plugs to decrease nasal leak (<xref ref-type="bibr" rid="B19">19</xref>). CPAP, continuous positive airway pressure.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-12-1313781-g001.tif"/>
</fig>
<p>One opportunity for advancement of this device is titration of the fraction of inspired oxygen (FiO<sub>2</sub>) delivered as this low-cost design usually uses 100&#x0025; oxygen. High concentrations of oxygen can have harmful effects in the brain, lungs, heart, and eyes in neonates (<xref ref-type="bibr" rid="B20">20</xref>&#x2013;<xref ref-type="bibr" rid="B22">22</xref>). Indeed, current guidelines for neonatal resuscitation recommend initially using 21&#x0025; oxygen in term neonates, instead of 100&#x0025; oxygen in order to avoid oxygen toxicity (<xref ref-type="bibr" rid="B23">23</xref>). Additionally, recent data have demonstrated significant associations between increased mortality and high oxygen levels among critically ill children outside of the neonatal period (<xref ref-type="bibr" rid="B24">24</xref>, <xref ref-type="bibr" rid="B25">25</xref>). BCPAP has largely been tested in neonates although the burden of pneumonia remains highest in children less than five years old. There is a gap in low-cost, high quality respiratory support that minimizes oxygen toxicity for these children (<xref ref-type="bibr" rid="B26">26</xref>). Lastly, current methods of delivering variable concentrations of oxygen are generally expensive (approximately 1,000 USD) and not available to hospitals in LMICs (<xref ref-type="bibr" rid="B27">27</xref>).</p>
<p>In 2019, our team successfully developed an oxygen blender prototype utilizing jet mixing principles (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>). By passing a high-velocity fluid jet (i.e., 100&#x0025; oxygen stream) past quiescent fluid (i.e., 21&#x0025; oxygen in room air), viscous shear forces promote mixing of the two fluids, allowing a titrated stream (i.e., &#x003C;100&#x0025; oxygen) of the two fluids to flow downstream to the patient. This blender, which we have called the LESS (Low-cost Entrainment Syringe System) O<sub>2</sub> blender is designed to complement modified low-cost bCPAP circuit design and, like the bCPAP design, only requires common hospital supplies to build. The total cost of parts per circuit, which includes the blender and the modifications to the circuit, amounts to approximately 1.40 USD (excluding oxygen costs). Based on bench testing, the LESS O<sub>2</sub> blender can decrease FiO<sub>2</sub> to approximately 60&#x0025;&#x2013;70&#x0025; and 40&#x0025;&#x2013;50&#x0025; with 5&#x2005;mm and 10&#x2005;mm entrainment ports, respectively (<xref ref-type="bibr" rid="B28">28</xref>). We then tested construction among new users, which was performed in the USA and Cambodia, and found that it can be reliably constructed to generate mixed oxygen flows (<xref ref-type="bibr" rid="B29">29</xref>). The next step in development of this blender was to test its safety in a relevant clinical setting. We performed a clinical trial to evaluate the safety and feasibility of implementation of the LESS O<sub>2</sub> blender with modified low-cost bCPAP in a children&#x0027;s hospital in rural Cambodia in 2022.</p>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>Bubble CPAP set-up with syringe oxygen blender in-line. Credit: Mara Halvorson.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-12-1313781-g002.tif"/>
</fig>
</sec>
<sec id="s2" sec-type="methods"><title>Methods</title>
<sec id="s2a"><title>Device development</title>
<p>A multidisciplinary team (clinical and engineering) began working together in 2019 to design the blender. The LESS O<sub>2</sub> blender utilizes the Venturi effect by funneling oxygen through a hypodermic needle that then exits near an entrainment port exposed to ambient air which facilitates blending of oxygen and room air in the delivered outflow oxygen tubing of the nasal cannula. It is designed to be constructed and assembled on site using two 3&#x2005;ml syringes with rubber plunger stops, one 22-gauge hypodermic needle, oxygen tubing, super glue or tape, and a blade (i.e., scalpel/razor blade). During bench testing, delivered oxygen concentrations can be approximately 65&#x0025; or 45&#x0025; using the 5&#x2005;mm entrainment port or 10&#x2005;mm port respectively, and results were published in 2020 in the Journal of Medical Devices (<xref ref-type="bibr" rid="B28">28</xref>). For this study, we also used the SEAL-bCPAP modification, which minimizes leak at the nares (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>) (<xref ref-type="bibr" rid="B19">19</xref>).</p>
</sec>
<sec id="s2b"><title>Ethics and institutional approvals</title>
<p>The Institutional Review Boards (IRBs) at the University of Minnesota, Boston Children&#x0027;s Hospital, and Chenla Children&#x0027;s Hospital reviewed and approved this study.</p>
<p>The device was exempt from Food and Drug Administration review since the device is not intended for use in the USA. Additionally, the LESS O<sub>2</sub> blender was given exemption from the determination protocols of the Department of Drugs and Food (DDF) in the Cambodian Ministry of Health given that the device has little to no sale potential, not intended to be sold in Cambodia; meets criteria for a low-risk device; and has no formal registration certificate from the country of export nor an associated company license given it is constructed on site.</p>
</sec>
<sec id="s2c"><title>Role of funding source</title>
<p>The study sponsors did not have a role in study design; collection, analysis, or interpretation of data; writing of the report; nor the decision to submit the paper for publication.</p>
</sec>
<sec id="s2d"><title>Study settings</title>
<p>The study took place at Chenla Children&#x0027;s Healthcare (CCH) located in Kratie, Cambodia, which is primarily rural and heavily affected by poverty. About one third of the residents live on &#x003C;1 USD a day. Chenla Children&#x0027;s Healthcare runs a 30-bed pediatric ward, including six pediatric intensive care (PICU) beds and ten neonatal intensive care (NICU) beds. At the time of study initiation, there were five ventilators. There are bCPAP machines available but not enough to provide every child who is admitted for respiratory distress. Of note, in 2020 when the study was planned in pre-COVID pandemic, CCH had five bCPAP machines which increased to 18 in 2022 when the study was launched. Despite this increase, malfunctions in bCPAP machines are common and there are frequently more children requiring bCPAP than machines available.</p>
</sec>
<sec id="s2e"><title>Device training and teaching</title>
<p>A team of Cambodian ICU nurses was trained on the study protocol and device construction via written instruction, in-person didactics, case discussions and simulated device building prior to study initiation. Constructed blenders that functioned as expected were kept for urgent use during study enrollment. The equipment and parts necessary to construct the low-cost bCPAP circuit and the syringe blender were provided.</p>
</sec>
<sec id="s2f"><title>Study design</title>
<p>This study was designed as a prospective cohort feasibility and safety pilot study. Patients were enrolled from March 2022 to March 2023. Participants were eligible if they met all criteria in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Inclusion and exclusion criteria.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Inclusion criteria</th>
<th valign="top" align="center">Exclusion criteria</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>5 years of age or younger</p></list-item>
</list>AND
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Admission diagnosis of a lower respiratory tract infection (LRTI) such as pneumonia or bronchiolitis
<list list-type="simple">
<list-item><label>&#x25E6;</label>
<p>For neonates (under 1 month of age), respiratory distress syndrome, transient tachypnea of the newborn, and meconium aspiration qualified for inclusion</p></list-item>
</list></p></list-item>
</list>AND
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Respiratory distress upon presentation to the hospital, defined as cough or trouble breathing plus at least one of the following
<list list-type="simple">
<list-item><label>&#x25E6;</label>
<p>&#x003C;92&#x0025; despite low flow oxygen</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Central cyanosis</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Tachypnea</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Chest indrawing</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Nasal flaring</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Grunting</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Head nodding</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Convulsions</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Lethargy</p></list-item>
<list-item><label>&#x25E6;</label>
<p>Inability to breastfeed or drink</p></list-item>
</list></p></list-item>
</list>AND
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>No bubble continuous positive airway pressure (bCPAP) machine is available for immediate use</p></list-item>
</list></td>
<td valign="top" align="left">
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>History of asthma</p></list-item>
<list-item><label>&#x2022;</label>
<p>Upper airway obstruction</p></list-item>
<list-item><label>&#x2022;</label>
<p>Diaphragmatic hernia</p></list-item>
<list-item><label>&#x2022;</label>
<p>Pneumothorax</p></list-item>
<list-item><label>&#x2022;</label>
<p>Acute Glasgow Coma score &#x003C;4</p></list-item>
<list-item><label>&#x2022;</label>
<p>Cleft Palate</p></list-item>
<list-item><label>&#x2022;</label>
<p>Cyanotic heart disease</p></list-item>
<list-item><label>&#x2022;</label>
<p>Congenital lung disease</p></list-item>
<list-item><label>&#x2022;</label>
<p>Bleeding disorders</p></list-item>
<list-item><label>&#x2022;</label>
<p>Imminent death within 2&#x2005;h</p></list-item>
<list-item><label>&#x2022;</label>
<p>Have had abdominal or thoracic surgery</p></list-item>
</list></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn1"><p>Eligible patients must have been five years old or younger, have an admission diagnosis of LRTI, and have respiratory distress. If a bCPAP machine was immediately available at the time of enrollment, the patient was not enrolled. If the patient presented with any of the exclusion criterion, the patient was not enrolled.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>Our target sample size was 50 to obtain preliminary feasibility and safety data. Written consent from parents/guardians was obtained prior to enrollment.</p>
<p>Enrolled patients were initiated on modified low-cost bCPAP without the LESS O<sub>2</sub> blender (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>). Once the patient achieved respiratory stability, which was defined as having an oxygen saturation &#x003E;90&#x0025; and capillary refill &#x003C;2&#x2005;s, the low-cost bCPAP circuit was replaced with the LESS O<sub>2</sub> blender circuit. Though LESS O<sub>2</sub> blender circuits from the training were available to use, nurses were encouraged to create new syringe blender bCPAP circuits to maximize cleanliness. Circuits were single-patient use. The TAL respiratory score was obtained on enrollment to assess the severity of respiratory distress before initiation of respiratory support (<xref ref-type="bibr" rid="B30">30</xref>).</p>
<p>After the LESS O<sub>2</sub> blender circuit was initiated, study nurses assessed the device 30&#x2005;min later to confirm device function and again at one hour to assess for clinical failure. Nurses evaluated device function every two hours, including measurement of the FiO<sub>2</sub> level at the nasal cannula via an oxygen analyzer placed over one nasal prong (Analytical Industries Palm D Oxygen Analyzer). Vitals and exam findings were documented every four hours. Due to limited lab availability, the only labs obtained for study purposes were a complete blood count, malaria rapid diagnostic testing (RDT), and a bedside blood gas and electrolyte analyzer, all of which are standard of care at the site. No malaria RDT was required for neonates. Titration of the FiO<sub>2</sub> and CPAP levels were left to the discretion of the ordering physician with use of continuous pulse oximetry, though training was provided for which entrainment port size could be utilized.</p>
<p>If the blender circuit was found to be malfunctioning (e.g., lack of bubbling, twisted tubing, oxygen leak) the patients were assessed for stability. Then the study nurse would troubleshoot the device. If troubleshooting required removal of the circuit from the patient, the patient was placed on low-cost bCPAP without the blender until the blender circuit was repaired or replaced.</p>
</sec>
<sec id="s2g"><title>Outcomes</title>
<p>The primary study outcome was clinical failure within one hour of changing to the LESS O<sub>2</sub> blender circuit. Clinical failure was defined as intubation, death, transfer to a higher level of care (i.e., another hospital), or two of the following:
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Oxygen saturation &#x003C;85&#x0025; after 30&#x2005;min of treatment</p></list-item>
<list-item><label>&#x2022;</label>
<p>Signs of respiratory distress, including indrawing, tracheal tugging, nasal flaring, or grunting</p></list-item>
<list-item><label>&#x2022;</label>
<p>Partial pressure of carbon dioxide &#x2265;60&#x2005;mmHg and pH &#x003C;7.2 on a capillary blood gas</p></list-item>
</list>The secondary outcomes of the study included the following:
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Number of times no bubbling was noted and/or blender/bCPAP circuit required repair or replacement</p></list-item>
<list-item><label>&#x2022;</label>
<p>Duration of respiratory support in hours</p></list-item>
<list-item><label>&#x2022;</label>
<p>Adverse events related to the blender circuit (described below)</p></list-item>
<list-item><label>&#x2022;</label>
<p>Outcome of hospitalization</p></list-item>
</list>Outcomes related to functioning of the LESS O<sub>2</sub> blender included the following:
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Size of entrainment port</p></list-item>
<list-item><label>&#x2022;</label>
<p>CPAP level</p></list-item>
<list-item><label>&#x2022;</label>
<p>Oxygen concentration (FiO<sub>2</sub>) of nasal cannula outflow</p></list-item>
<list-item><label>&#x2022;</label>
<p>Flow of oxygen from tank</p></list-item>
</list>Adverse events were documented in detail and were defined as either grade I or grade II, with the latter considered serious adverse events (SAE) and characterized by associated clinical decline. Adverse events could be related to the modified circuit (nasal injury, nose bleeding, aerophagia, pneumothorax, device fragmentation at circuit connections) or the blender itself (loss of CPAP, oxygen leak, device fragmentation).</p>
</sec>
<sec id="s2h"><title>Statistical analysis</title>
<p>Descriptive statistics (means and standard deviations or medians and IQR for continuous variables; counts and percent for categorical variables) were used to summarize patient demographics and outcomes. The clinical failure rate was estimated along with an exact binomial 95&#x0025; confidence interval. Spearman correlation coefficients, Kruskal&#x2013;Wallis tests and Wilcoxon rank sum tests were used to compare variables of interest with duration of respiratory support, number of repairs, and number of replacements. A linear mixed effect model was used to compare mean FiO<sub>2</sub> between port sizes while controlling for CPAP level and flow. A random patient effect was included to account for multiple tracking measures per patient. SAS V9.4 (SAS Institute Inc., Cary, NC) was used for the analysis.</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><title>Results</title>
<p>Thirty-three patients were enrolled (<xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref>). The majority were male (66.7&#x0025;), less than three months old (76&#x0025;), and term gestation (88&#x0025;). At enrollment, 91&#x0025; were deemed stable, and 65.2&#x0025; had moderate respiratory distress (<xref ref-type="table" rid="T2">Table&#x00A0;2</xref>). The mean respiratory rate on admission was 52 breaths per minute (SD 8) and the mean oxygen saturation on admission was 93.5&#x0025; (SD 6.6&#x0025;).</p>
<fig id="F3" position="float"><label>Figure 3</label>
<caption><p>Flowchart of enrollment. bCPAP, bubble continuous positive airway pressure.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-12-1313781-g003.tif"/>
</fig>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>Baseline demographics and characteristics.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left"/>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;33</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="2">Gender, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Female</td>
<td valign="top" align="center">11 (34&#x00B7;4)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Male</td>
<td valign="top" align="center">22 (68&#x00B7;8)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Age, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;&#x003C;1 months</td>
<td valign="top" align="center">15 (45&#x00B7;5)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;1&#x2013;3 months</td>
<td valign="top" align="center">10 (30&#x00B7;3)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;4&#x002B; months</td>
<td valign="top" align="center">8 (24&#x00B7;2)</td>
</tr>
<tr>
<td valign="top" align="left">Stable on enrollment, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">30 (90&#x00B7;9)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Gestational age at birth, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;30&#x2013;36 weeks</td>
<td valign="top" align="center">4 (12&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;37&#x2013;38 weeks</td>
<td valign="top" align="center">4 (12&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;39 weeks-Full term</td>
<td valign="top" align="center">25 (75&#x00B7;8)</td>
</tr>
<tr>
<td valign="top" align="left">Weight (kg), mean (SD)</td>
<td valign="top" align="center">4&#x00B7;6 (2&#x00B7;0)</td>
</tr>
<tr>
<td valign="top" align="left">Oxygen saturation, mean (SD)</td>
<td valign="top" align="center">93&#x00B7;5 (6&#x00B7;6)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Respiratory distress based on Tal Score, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Mild respiratory distress</td>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Moderate respiratory distress</td>
<td valign="top" align="center">11 (33&#x00B7;4)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Severe respiratory distress</td>
<td valign="top" align="center">22 (66&#x00B7;6)</td>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="center">0 (0&#x00B7;0)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Pediatric Early Warning Sign (PEWS) Score, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Mild</td>
<td valign="top" align="center">28 (84&#x00B7;8)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Moderate</td>
<td valign="top" align="center">5 (15&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Severe</td>
<td valign="top" align="center">0 (0&#x00B7;0)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn2"><p>Data are demonstrated as count and proportions unless otherwise noted.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>One patient was withdrawn due to the parental request to leave against medical advice and was never placed on the LESS O<sub>2</sub> blender, leaving 32 participants who used the LESS O<sub>2</sub> blender circuit. One patient met criteria for the primary outcome of clinical failure 40&#x2005;min post initiation of the LESS O<sub>2</sub> blender (3.1&#x0025;, 95&#x0025; CI&#x2009;&#x003D;&#x2009;0.1&#x0025;&#x2013;16.2&#x0025;). Of note, this patient who failed did not receive 30&#x2005;min of treatment prior to escalation due to acuity of the clinical situation and physician clinical judgement (i.e., was immediately escalated and eventually intubated). One patient who died during the hospitalization from septic shock (not study related) was escalated to machine bCPAP after eight hours on the LESS O<sub>2</sub> blender circuit due to hypoxemia and central cyanosis felt to be due to disease progression. The remaining 31 patients, including the one who failed the blender, were eventually discharged home. Four patients were escalated to machine bCPAP on request of the physician and these transitions occurred after completing the first hour on the LESS O<sub>2</sub> blender. Capillary gases were obtained on all participants as per hospital protocol, but no patients met clinical failure criteria based on the results.</p>
<p>Most adverse events recorded were due to lack of bubbling, accounting for 64&#x0025; (18/28 events in 19 patients) of the events (<xref ref-type="table" rid="T3">Table&#x00A0;3</xref>). Lack of bubbling was caused by leak in the circuit requiring tape or straightening of the entrainment port; incorrect entrainment port size; the expiratory limb accidentally retracting from the water; using nasal prongs too small for the child; and child crying (i.e., leak from mouth). No adverse events were documented as severe. Fourteen patients had their blender circuit repaired at least once with 10/14 requiring only one repair. Examples of repairs included reinforcing circuit leaks with tape or glue, realigning needle, untwisting entrainment port, and re-inserting expiratory limb in the water or adding more water. Eight patients required circuit replacement, with 6/8 requiring only one replacement. Most replacements were done for lack of bubbling, followed by troubleshooting without success and then replacement. Experiencing more repairs or replacements were not significantly correlated with weight, age, gender, gestational age, or TAL respiratory score. There were two nasal septal injuries which were grade I and described as &#x201C;redness of the nose&#x201D;.</p>
<table-wrap id="T3" position="float"><label>Table 3</label>
<caption><p>Summary of outcomes and adverse events.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left"/>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;32</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Clinical failure, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">1 (3&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Number of times no bubbling/Continuous positive airway pressure (CPAP) failure noted, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;0</td>
<td valign="top" align="center">15 (46&#x00B7;9)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;1</td>
<td valign="top" align="center">9 (28&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;2</td>
<td valign="top" align="center">4 (12&#x00B7;5)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;3</td>
<td valign="top" align="center">4 (12&#x00B7;5)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Number of times blender required repair, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;0</td>
<td valign="top" align="center">18 (56&#x00B7;3)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;1</td>
<td valign="top" align="center">10 (31&#x00B7;3)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;2</td>
<td valign="top" align="center">3 (9&#x00B7;4)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;3</td>
<td valign="top" align="center">1 (3&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Number of times blender required replacement, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;0</td>
<td valign="top" align="center">24 (75&#x00B7;0)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;1</td>
<td valign="top" align="center">6 (18&#x00B7;8)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;2</td>
<td valign="top" align="center">1 (3&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;3</td>
<td valign="top" align="center">1 (3&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">Number of patients who experienced adverse event(s), <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">19 (59&#x00B7;4)</td>
</tr>
<tr>
<td valign="top" align="left">Loss of CPAP, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">15 (46&#x00B7;9)</td>
</tr>
<tr>
<td valign="top" align="left">Device fragmentation of blender, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">5 (15&#x00B7;6)</td>
</tr>
<tr>
<td valign="top" align="left">Nasal septal injury, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">2 (6&#x00B7;3)</td>
</tr>
<tr>
<td valign="top" align="left">Other, <italic>n</italic> (&#x0025;)</td>
<td valign="top" align="center">6 (18&#x00B7;8)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Duration of respiratory support (hours)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Median (IQR)</td>
<td valign="top" align="center">44&#x00B7;0 (13&#x00B7;6&#x2013;78&#x00B7;0)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Hospitalization outcome, <italic>n</italic> (&#x0025;)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Die</td>
<td valign="top" align="center">1 (3&#x00B7;1)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2003;Discharge</td>
<td valign="top" align="center">31 (96&#x00B7;9)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn3"><p>Thirty-two patients are represented here instead of 33 as one patient withdrew from the study before initiation of the LESS O<sub>2</sub> blender. Data are demonstrated as count and proportions unless otherwise noted.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>The median duration of respiratory support was 44&#x2005;h (IQR 13.6&#x2013;78.0&#x2005;h). The median (IQR) time to CPAP loss was 10.5&#x2005;h (4.0&#x2013;28.8). The median duration of support among children who experienced loss of CPAP was the same as the median duration of support among those who did not experience loss of CPAP (44 vs. 44&#x2005;h, <italic>p</italic>&#x2009;&#x003D;&#x2009;0.72). Similarly, duration of support did not differ statistically across weight (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.27), gestational age (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.83), age at admission (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.89), gender (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.37), presence of a danger sign (e.g., inability to feed, convulsions, or decreased level of consciousness) (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.98), or meeting sepsis criteria (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.11).</p>
<p>The average FiO<sub>2</sub> delivered by the syringe blender circuit with any entrainment port size was 54.1&#x0025; (SD 8.7&#x0025;). The average minimum FiO<sub>2</sub> was 47.5&#x0025; (SD 8.6&#x0025;) and the average maximum was 61.9&#x0025; (SD 12.1&#x0025;). The 10&#x2005;mm entrainment port was used more often than the 5&#x2005;mm (70&#x0025; vs. 30&#x0025; of recorded port lengths, respectively). <xref ref-type="fig" rid="F4">Figure&#x00A0;4</xref> displays the FiO<sub>2</sub> generated as it varied by flow and CPAP level used. The average FiO<sub>2</sub> of the 5&#x2005;mm port was 59.0&#x0025; and the average FiO<sub>2</sub> of the 10&#x2005;mm port was 52.1&#x0025; (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.0001).</p>
<fig id="F4" position="float"><label>Figure 4</label>
<caption><p>Histogram displaying measured oxygen concentrations of the gas mixture at the nasal prongs of the LESS O<sub>2</sub> blender circuit. The left half demonstrates measurements using a 5&#x2005;mm entrainment port and the right demonstrates measurements using a 10&#x2005;mm entrainment port. Oxygen concentrations are graphed across flows in liters per minute (LPM) and by CPAP level in cm H<sub>2</sub>O. CPAP, continuous positive airway pressure.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-12-1313781-g004.tif"/>
</fig>
</sec>
<sec id="s4" sec-type="discussion"><title>Discussion</title>
<p>Our study sought to test the safety and feasibility of a novel, constructible oxygen blender designed to be used with low-cost, modified bCPAP with the SEAL-bCPAP modification. The burden of pediatric mortality from pneumonia disproportionately occurs in LMICs where respiratory support technology can be very limited. Our device is an additional tool for practitioners caring for sick children in the most resource-limited settings as it can provide both respiratory support with less oxygen toxicity and without electricity. Overall, we found our device to be safe based on low clinical failure among the population tested, and it provided mixed oxygen concentrations to minimize hyperoxia, though circuit leaks required attention. Nurses were available to troubleshoot the device and continuous pulse oximetry was always used. On average, patients were found to have moderate respiratory distress on enrollment based on increased work of breathing and to a lesser degree, hypoxemia.</p>
<p>A similar study was conducted in a 2016 study in India using an aquarium air pump with bCPAP to deliver mixed oxygen concentrations of 42&#x0025;&#x2013;51&#x0025; (<xref ref-type="bibr" rid="B31">31</xref>). No patients decompensated with blender use. Of note, this study has a couple of key differences from our proposed study. First, our study enrolled patients up to 5 years versus only neonates in the Indian study. Second, our device does not require electricity or purchase of a pre-made device, whereas this study in India required a reliable source of electricity and a specific type of aquarium air pump. In recent years, there have also been other groups, such as PATH and Vayu Global Health Innovations, developing low-cost oxygen blenders designed for bCPAP, which is excellent as these open up options for practitioners in LMICs (<xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B33">33</xref>). Of note, these devices are usually either 3D-printed or injection molded in the HIC and then transported. In contrast, our blender can be constructed on site with common medical supplies, which provides an avenue for the most resource-restricted areas to have access to methods of reducing oxygen concentrations without additional funding or dependency on high-resource countries for supplies.</p>
<p>We originally hypothesized that the most anticipated concern with the circuit would be leaks of oxygen, leading to loss of bubbling and therefore CPAP, due to the multiple connections required in the blender&#x0027;s construction. Based on our findings, these leaks were largely due to the modified nasal interface. Our design requires the &#x201C;implantation&#x201D; of nasal prongs onto oxygen tubing, which allows for CPAP to occur since the tubing is larger bore. However, this design introduces potential leak at the site of implantation. An additional issue was that oxygen tubing is relatively inflexible (compared to smaller, more compliant nasal cannula tubing), which led to prongs repeatedly coming out of the nares when used with a physically active child. Many bCPAP circuits use large bore, high resistance tubing with short binasal prongs or a mask (<xref ref-type="bibr" rid="B9">9</xref>). Taken together, the LESS O<sub>2</sub> blender provides the advantage of being constructed on site and therefore an element of self-sufficiency. However, the constructible aspect also introduces a level of imprecision that demands close monitoring of the presence of bubbling. This also translated to increased vigilance and time spent by the nursing and physician teams to monitor the patients very closely. Therefore, use of this device requires enough medical staff to be present and attentive. Of note, six nurses identified by the on-site Cambodia-based investigator (SL) as having exceptional skill in constructing the blenders were deemed &#x201C;superusers&#x201D; and tasked with building the circuits if one was needed urgently (i.e., if replacement was required) or if any troubleshooting problems arose. This was a strategy we implemented in order to mitigate mechanical device problems after DSMB review at the mid-point of the study. This device is not intended to supplant a precision manufactured device. The LESS O<sub>2</sub> blender circuit is designed for use where the only other options are either low flow nasal cannula or low-cost, constructible bCPAP using 100&#x0025; oxygen.</p>
<p>In a previous study, the relationships among FiO<sub>2</sub>, flow, and CPAP level in our device were explored. Among circuits with a 10&#x2005;mm entrainment port, the FiO<sub>2</sub> remained constant across flows 3&#x2013;10&#x2005;LPM and varied slightly (&#x00B1;3 points) across CPAP levels (1&#x2013;8&#x2005;cm H<sub>2</sub>O). Conversely, circuits with a 5&#x2005;mm entrainment port delivered FiO<sub>2</sub>&#x0027;s that were constant unless flows were &#x003C;4&#x2005;LPM, at which point the FiO<sub>2</sub> would typically increase by 5&#x2013;10 points (<xref ref-type="bibr" rid="B28">28</xref>). This occurred due to a lower pressure gradient with lower flows, leading to reduced entrainment of room air in the gas mixture. We noted that higher CPAP levels correlated with FiO<sub>2</sub>, which was likely from increased back pressure resulting in less entrainment of room air as well. In this clinical study, we found similar patterns&#x2014;specifically FiO<sub>2</sub> largely remained constant across flow rates and higher CPAP levels were associated with higher delivered FiO<sub>2</sub> in the circuits with only the 5&#x2005;mm port. For these reasons, we advise practitioners using the LESS O<sub>2</sub> blender be aware that as the CPAP is increased, the FiO<sub>2</sub> will likely increase as well. We limited our CPAP to &#x2264;8&#x2005;cm H<sub>2</sub>O. Flow should be increased just enough to generate gentle bubbling throughout the respiratory cycle (<xref ref-type="bibr" rid="B34">34</xref>).</p>
<p>Limitations include the inability to measure either a reduction in oxygen toxicity (i.e., free radicals) or decrease in mortality, both impractical for our purposes. Additionally, our study population was largely term infants with mild-to-moderate respiratory distress. Patients with severe respiratory distress or those &#x003E;8 months old may not be adequately supported with this device. The target sample size of 50 was not achieved due to lack of enrollment by the pre-determined study end time of March 2023. Despite estimated calculations of an appropriate timeline to reach the target sample size, the COVID19 pandemic caused significant delays in both the USA and Cambodia leading to a delayed study start in 2022, at which time the hospital had acquired many more bCPAP machines which hindered higher enrollment rates. The end time of March 2023 (i.e., one year study duration) was limited by funding. Despite these barriers, the enrolled sample size was adequate and appropriate to provide valuable data about feasibility and safety.</p>
</sec>
<sec id="s5" sec-type="conclusions"><title>Conclusion</title>
<p>The ability of the LESS O<sub>2</sub> blender to reliably deliver blended oxygen and reduce the burden of hyperoxia is a major benefit of its use. Leaks noted in the circuit were the most frequent issue. If the bubbling is not present constantly (<xref ref-type="bibr" rid="B34">34</xref>), practitioners should inspect for leaks at the nasal cannula, the blender housing connections, and/or the entrainment port. The instructions for device use and construction are included with this publication (See <xref ref-type="sec" rid="s11">Supplementary Materials</xref>). The authors intend for the LESS O<sub>2</sub> blender to be open source and available to learn, use, and modify as needed by providers around the world.</p>
<p>As next steps, our team plans on improving the nasal interface and identifying ways to modify the oxygen tubing such that leaks will be minimized but that also less handling by the medical staff during use may be required.</p>
<p>The LESS O<sub>2</sub> blender is ready to use in the field for practitioners caring for children in very resource-limited settings, such as areas without reliable electricity, compressed air, limited international bandwidth, or restricted funding. We emphasize that medical staff should remain attentive to the presence of bubbling and the integrity of the device if it is to be used and that continuous oximetry should be placed on the patient. Additionally, the instructions and guidelines included in this publication should be carefully read before deciding to use (See <xref ref-type="sec" rid="s11">Supplementary Materials</xref>). Currently, there is no low-cost oxygen blender for bubble CPAP that can be assembled on site to our knowledge, allowing the LESS O<sub>2</sub> blender to address this current critical gap.</p>
</sec>
</body>
<back>
<sec id="s6" sec-type="data-availability"><title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s11"><bold>Supplementary Material</bold></xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s7" sec-type="ethics-statement"><title>Ethics statement</title>
<p>The studies involving humans were approved by the Boston Children&#x0027;s Hospital Institutional Review Board (IRB), University of Minnesota IRB, and Chenla Children&#x0027;s Ethic Committee. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation in this study was provided by the participants&#x2019; legal guardians/next of kin.</p>
</sec>
<sec id="s8" sec-type="author-contributions"><title>Author contributions</title>
<p>AW: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Visualization, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. SrL: Conceptualization, Data curation, Investigation, Methodology, Project administration, Supervision, Validation, Writing &#x2013; review &#x0026; editing. TS: Conceptualization, Investigation, Methodology, Project administration, Resources, Supervision, Writing &#x2013; review &#x0026; editing. GF: Conceptualization, Funding acquisition, Resources, Supervision, Writing &#x2013; review &#x0026; editing. ScL: Formal Analysis, Resources, Software, Writing &#x2013; review &#x0026; editing. AB: .</p>
</sec>
<sec id="s9" sec-type="funding-information"><title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article.</p>
<p>National Institutes of Health&#x2019;s National Center for Advancing Translational Sciences, grant UL1TR002494, The Pediatric Device Innovation Consortium at the University of Minnesota, the Frank J and Eleanor A Maslowski Charitable Trust. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health&#x2019;s National Center for Advancing Translational Sciences. Additional support was provided by The Pediatric Device Innovation Consortium at the University of Minnesota and the FJ and EM Charitable Trust.</p>
</sec>
<ack><title>Acknowledgments</title>
<p>AW was affiliated with the University of Minnesota during the conception and start of the trial, with Boston Children&#x0027;s Hospital during and at the conclusion of the trial, and with Hennepin Healthcare currently.</p>
</ack>
<sec id="s10" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s12" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s11" sec-type="supplementary-material"><title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fped.2024.1313781/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fped.2024.1313781/full&#x0023;supplementary-material</ext-link></p>
<supplementary-material id="SD1" content-type="local-data">
<media mimetype="application" mime-subtype="vnd.openxmlformats-officedocument.wordprocessingml.document" xlink:href="Datasheet1.docx"/>
</supplementary-material>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><collab>Collaboration GBoDP</collab>. <article-title>Global and national burden of diseases and injuries among children and adolescents between 1990 and 2013: findings from the global burden of disease 2013 study</article-title>. <source>JAMA Pediatr</source>. (<year>2016</year>) <volume>170</volume>(<issue>3</issue>):<fpage>267</fpage>&#x2013;<lpage>87</lpage>. <pub-id pub-id-type="doi">10.1001/jamapediatrics.2015.4276</pub-id><pub-id pub-id-type="pmid">26810619</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lim</surname><given-names>SS</given-names></name><name><surname>Vos</surname><given-names>T</given-names></name><name><surname>Flaxman</surname><given-names>AD</given-names></name><name><surname>Danaei</surname><given-names>G</given-names></name><name><surname>Shibuya</surname><given-names>K</given-names></name><name><surname>Adair-Rohani</surname><given-names>H</given-names></name><etal/></person-group> <article-title>A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990&#x2013;2010: a systematic analysis for the global burden of disease study 2010</article-title>. <source>Lancet</source>. (<year>2012</year>) <volume>380</volume>(<issue>9859</issue>):<fpage>2224</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(12)61766-8</pub-id><pub-id pub-id-type="pmid">23245609</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>L</given-names></name><name><surname>Oza</surname><given-names>S</given-names></name><name><surname>Hogan</surname><given-names>D</given-names></name><name><surname>Chu</surname><given-names>Y</given-names></name><name><surname>Perin</surname><given-names>J</given-names></name><name><surname>Zhu</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Global, regional, and national causes of under-5 mortality in 2000-15: an updated systematic analysis with implications for the sustainable development goals</article-title>. <source>Lancet (London, England)</source>. (<year>2016</year>) <volume>388</volume>(<issue>10063</issue>):<fpage>3027</fpage>&#x2013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(16)31593-8</pub-id><pub-id pub-id-type="pmid">27839855</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="other"><collab>Organization WH</collab>. <comment>Child Mortality (under 5 years)</comment>. (<year>2022</year>). <comment>Available online at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.who.int/news-room/fact-sheets/detail/levels-and-trends-in-child-under-5-mortality-in-2020#:&#x223C;:text=Globally%2C%20infectious%20diseases%2C%20including%20pneumonia,for%20children%20under%205%20years">https://www.who.int/news-room/fact-sheets/detail/levels-and-trends-in-child-under-5-mortality-in-2020&#x0023;:&#x223C;:text&#x003D;Globally&#x0025;2C&#x0025;20infectious&#x0025;20diseases&#x0025;2C&#x0025;20including&#x0025;20pneumonia,for&#x0025;20children&#x0025;20under&#x0025;205&#x0025;20years</ext-link> <comment>(Accessed March 24, 2023)</comment>.</citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Compton</surname><given-names>B</given-names></name><name><surname>Barash</surname><given-names>DM</given-names></name><name><surname>Farrington</surname><given-names>J</given-names></name><name><surname>Hall</surname><given-names>C</given-names></name><name><surname>Herzog</surname><given-names>D</given-names></name><name><surname>Meka</surname><given-names>V</given-names></name><etal/></person-group> <comment>Access to Medical Devices in Low-income Countries: Addressing Sustainability Challenges in Medical Device Donations</comment>. (<year>2018</year>). <comment>Available online at:</comment> <ext-link ext-link-type="uri" xlink:href="https://nam.edu/access-to-medical-devices-in-low-income-countries-addressing-sustainability-challenges-in-medical-device-donations/">https://nam.edu/access-to-medical-devices-in-low-income-countries-addressing-sustainability-challenges-in-medical-device-donations/</ext-link> <comment>(Accessed March 25, 2023)</comment>.</citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Pinto</surname><given-names>VL</given-names></name><name><surname>Sharma</surname><given-names>S</given-names></name></person-group>. <article-title>Continuous positive airway pressure</article-title>. In: <person-group person-group-type="editor"><name><surname>Aboubakr</surname><given-names>S</given-names></name></person-group>, editor. <source>Statpearls</source>. <publisher-loc>Treasure Island, FL</publisher-loc>: <publisher-name>StatPearls Publishing</publisher-name> (<year>2023</year>).</citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Avery</surname><given-names>ME</given-names></name><name><surname>Tooley</surname><given-names>WH</given-names></name><name><surname>Keller</surname><given-names>JB</given-names></name><name><surname>Hurd</surname><given-names>SS</given-names></name><name><surname>Bryan</surname><given-names>MH</given-names></name><name><surname>Cotton</surname><given-names>RB</given-names></name><etal/></person-group> <article-title>Is chronic lung disease in low birth weight infants preventable? A survey of eight centers</article-title>. <source>Pediatrics</source>. (<year>1987</year>) <volume>79</volume>(<issue>1</issue>):<fpage>26</fpage>&#x2013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1542/peds.79.1.26</pub-id><pub-id pub-id-type="pmid">3797169</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chan</surname><given-names>KM</given-names></name><name><surname>Chan</surname><given-names>HB</given-names></name></person-group>. <article-title>The use of bubble CPAP in premature infants: local experience</article-title>. <source>Hong Kong J Paediatr</source>. (<year>2007</year>) <volume>12</volume>:<fpage>86</fpage>&#x2013;<lpage>92</lpage>.</citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baldursdottir</surname><given-names>S</given-names></name><name><surname>Falk</surname><given-names>M</given-names></name><name><surname>Donaldsson</surname><given-names>S</given-names></name><name><surname>Jonsson</surname><given-names>B</given-names></name><name><surname>Drevhammar</surname><given-names>T</given-names></name></person-group>. <article-title>Basic principles of neonatal bubble CPAP: effects on CPAP delivery and imposed work of breathing when altering the original design</article-title>. <source>Arch Dis Child Fetal Neonatal Ed</source>. (<year>2020</year>) <volume>105</volume>(<issue>5</issue>):<fpage>550</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1136/archdischild-2019-318073</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sahni</surname><given-names>R</given-names></name><name><surname>Wung</surname><given-names>JT</given-names></name></person-group>. <article-title>Continuous positive airway pressure (CPAP)</article-title>. <source>Indian J Pediatr</source>. (<year>1998</year>) <volume>65</volume>(<issue>2</issue>):<fpage>265</fpage>&#x2013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1007/BF02752303</pub-id><pub-id pub-id-type="pmid">10771972</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Martin</surname><given-names>S</given-names></name><name><surname>Duke</surname><given-names>T</given-names></name><name><surname>Davis</surname><given-names>P</given-names></name></person-group>. <article-title>Efficacy and safety of bubble CPAP in neonatal care in low and middle income countries: a systematic review</article-title>. <source>Arch Dis Child Fetal Neonatal Ed</source>. (<year>2014</year>) <volume>99</volume>(<issue>6</issue>):<fpage>F495</fpage>&#x2013;<lpage>504</lpage>. <pub-id pub-id-type="doi">10.1136/archdischild-2013-305519</pub-id><pub-id pub-id-type="pmid">25085942</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Won</surname><given-names>A</given-names></name><name><surname>Suarez-Rebling</surname><given-names>D</given-names></name><name><surname>Baker</surname><given-names>AL</given-names></name><name><surname>Burke</surname><given-names>TF</given-names></name><name><surname>Nelson</surname><given-names>BD</given-names></name></person-group>. <article-title>Bubble CPAP devices for infants and children in resource-limited settings: review of the literature</article-title>. <source>Paediatr Int Child Health</source>. (<year>2019</year>) <volume>39</volume>(<issue>3</issue>):<fpage>168</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1080/20469047.2018.1534389</pub-id><pub-id pub-id-type="pmid">30375281</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Duke</surname><given-names>T</given-names></name></person-group>. <article-title>CPAP and high-flow oxygen to address high mortality of very severe pneumonia in low-income countries&#x2014;keeping it in perspective</article-title>. <source>Paediatr Int Child Health</source>. (<year>2019</year>) <volume>39</volume>(<issue>3</issue>):<fpage>155</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1080/20469047.2019.1613782</pub-id><pub-id pub-id-type="pmid">31241014</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thukral</surname><given-names>A</given-names></name><name><surname>Sankar</surname><given-names>MJ</given-names></name><name><surname>Chandrasekaran</surname><given-names>A</given-names></name><name><surname>Agarwal</surname><given-names>R</given-names></name><name><surname>Paul</surname><given-names>VK</given-names></name></person-group>. <article-title>Efficacy and safety of CPAP in low- and middle-income countries</article-title>. <source>J Perinatol</source>. (<year>2016</year>) <volume>36</volume>(<issue>1</issue>):<fpage>S21</fpage>&#x2013;<lpage>S8</lpage>. <pub-id pub-id-type="doi">10.1038/jp.2016.29</pub-id><pub-id pub-id-type="pmid">27109089</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Murphy</surname><given-names>S</given-names></name><name><surname>Geistkemper</surname><given-names>A</given-names></name></person-group>. <article-title>Benefits of BCPAP guidelines and the reduction of BPD in the NICU</article-title>. <source>Respir Care</source>. (<year>2019</year>) <volume>64</volume>(<issue>Suppl 10</issue>):<fpage>3229360</fpage>.</citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mwatha</surname><given-names>AB</given-names></name><name><surname>Mahande</surname><given-names>M</given-names></name><name><surname>Olomi</surname><given-names>R</given-names></name><name><surname>John</surname><given-names>B</given-names></name><name><surname>Philemon</surname><given-names>R</given-names></name></person-group>. <article-title>Treatment outcomes of pumani bubble-CPAP versus oxygen therapy among preterm babies presenting with respiratory distress at a tertiary hospital in Tanzania-randomised trial</article-title>. <source>PloS One</source>. (<year>2020</year>) <volume>15</volume>(<issue>6</issue>):<fpage>e0235031</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0235031</pub-id><pub-id pub-id-type="pmid">32603380</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>M</surname><given-names>LD</given-names></name><name><surname>Ng</surname><given-names>EK</given-names></name><name><surname>A</surname><given-names>MB</given-names></name><name><surname>DiBlasi</surname><given-names>RM</given-names></name><name><surname>Poli</surname><given-names>JA</given-names></name><name><surname>Burke</surname><given-names>TF</given-names></name></person-group>. <article-title>Evaluation of a bubble CPAP system for low resource settings</article-title>. <source>Respir Care</source>. (<year>2021</year>) <volume>66</volume>(<issue>10</issue>):<fpage>1572</fpage>&#x2013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.4187/respcare.08948</pub-id><pub-id pub-id-type="pmid">33824173</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="book"><collab>Organization WH</collab>. <source>Oxygen Therapy for Children: A Manual for Health Workers</source>. <publisher-loc>Geneva</publisher-loc>: <publisher-name>World Health Organization</publisher-name> (<year>2016</year>).</citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bjorklund</surname><given-names>AR</given-names></name><name><surname>Odongkara Mpora</surname><given-names>B</given-names></name><name><surname>Steiner</surname><given-names>ME</given-names></name><name><surname>Fischer</surname><given-names>G</given-names></name><name><surname>Davey</surname><given-names>CS</given-names></name><name><surname>Slusher</surname><given-names>TM</given-names></name></person-group>. <article-title>Use of a modified bubble continuous positive airway pressure (bCPAP) device for children in respiratory distress in low- and middle-income countries: a safety study</article-title>. <source>Paediatr Int Child Health</source>. (<year>2019</year>) <volume>39</volume>(<issue>3</issue>):<fpage>160</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1080/20469047.2018.1474698</pub-id><pub-id pub-id-type="pmid">29912645</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thomson</surname><given-names>L</given-names></name><name><surname>Paton</surname><given-names>J</given-names></name></person-group>. <article-title>Oxygen toxicity</article-title>. <source>Paediatr Respir Rev</source>. (<year>2014</year>) <volume>15</volume>(<issue>2</issue>):<fpage>120</fpage>&#x2013;<lpage>3</lpage>. <pub-id pub-id-type="doi">10.1016/j.prrv.2014.03.003</pub-id><pub-id pub-id-type="pmid">24767867</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Matalon</surname><given-names>S</given-names></name><name><surname>Nesarajah</surname><given-names>MS</given-names></name><name><surname>Farhi</surname><given-names>LE</given-names></name></person-group>. <article-title>Pulmonary and circulatory changes in conscious sheep exposed to 100&#x0025; O2 at 1 ATA</article-title>. <source>J Appl Physiol Respir Environ Exerc Physiol</source>. (<year>1982</year>) <volume>53</volume>(<issue>1</issue>):<fpage>110</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1152/jappl.1982.53.1.110</pub-id><pub-id pub-id-type="pmid">6811521</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bashinsky</surname><given-names>AL</given-names></name></person-group>. <article-title>Retinopathy of prematurity</article-title>. <source>North Carolina Med J</source>. (<year>2017</year>) <volume>78</volume>(<issue>2</issue>):<fpage>124</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.18043/ncm.78.2.124</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname><given-names>E</given-names></name><name><surname>Nguyen</surname><given-names>M</given-names></name></person-group>. <article-title>Oxygen therapy for neonatal resuscitation in the delivery room</article-title>. <source>NeoReviews</source>. (<year>2019</year>) <volume>20</volume>(<issue>9</issue>):<fpage>e500</fpage>&#x2013;<lpage>e12</lpage>. <pub-id pub-id-type="doi">10.1542/neo.20-9-e500</pub-id><pub-id pub-id-type="pmid">31477598</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lilien</surname><given-names>TA</given-names></name><name><surname>Groeneveld</surname><given-names>NS</given-names></name><name><surname>van Etten-Jamaludin</surname><given-names>F</given-names></name><name><surname>Peters</surname><given-names>MJ</given-names></name><name><surname>Buysse</surname><given-names>CMP</given-names></name><name><surname>Ralston</surname><given-names>SL</given-names></name><etal/></person-group> <article-title>Association of arterial hyperoxia with outcomes in critically ill children: a systematic review and meta-analysis</article-title>. <source>JAMA Network Open</source>. (<year>2022</year>) <volume>5</volume>(<issue>1</issue>):<fpage>e2142105-e</fpage>. <pub-id pub-id-type="doi">10.1001/jamanetworkopen.2021.42105</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pelletier</surname><given-names>JH</given-names></name><name><surname>Ramgopal</surname><given-names>S</given-names></name><name><surname>Horvat</surname><given-names>CM</given-names></name></person-group>. <article-title>Hyperoxemia is associated with mortality in critically ill children</article-title>. <source>Front Med (Lausanne)</source>. (<year>2021</year>) <volume>8</volume>. <pub-id pub-id-type="doi">10.3389/fmed.2021.675293</pub-id><pub-id pub-id-type="pmid">34164417</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chisti</surname><given-names>MJ</given-names></name><name><surname>Salam</surname><given-names>MA</given-names></name><name><surname>Smith</surname><given-names>JH</given-names></name><name><surname>Ahmed</surname><given-names>T</given-names></name><name><surname>Pietroni</surname><given-names>MA</given-names></name><name><surname>Shahunja</surname><given-names>KM</given-names></name><etal/></person-group> <article-title>Bubble continuous positive airway pressure for children with severe pneumonia and hypoxaemia in Bangladesh: an open, randomised controlled trial</article-title>. <source>Lancet (London, England)</source>. (<year>2015</year>) <volume>386</volume>(<issue>9998</issue>):<fpage>1057</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(15)60249-5</pub-id><pub-id pub-id-type="pmid">26296950</pub-id></citation></ref>
<ref id="B27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hardavella</surname><given-names>G</given-names></name><name><surname>Karampinis</surname><given-names>I</given-names></name><name><surname>Frille</surname><given-names>A</given-names></name><name><surname>Sreter</surname><given-names>K</given-names></name><name><surname>Rousalova</surname><given-names>I</given-names></name></person-group>. <article-title>Oxygen devices and delivery systems</article-title>. <source>Breathe (Sheffield, England)</source>. (<year>2019</year>) <volume>15</volume>(<issue>3</issue>):<fpage>e108</fpage>&#x2013;<lpage>e16</lpage>. <pub-id pub-id-type="doi">10.1183/20734735.0204-2019</pub-id><pub-id pub-id-type="pmid">31777573</pub-id></citation></ref>
<ref id="B28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Floersch</surname><given-names>J</given-names></name><name><surname>Hauschildt</surname><given-names>E</given-names></name><name><surname>Keester</surname><given-names>A</given-names></name><name><surname>Poganski</surname><given-names>S</given-names></name><name><surname>Tran</surname><given-names>K</given-names></name><name><surname>Slusher</surname><given-names>T</given-names></name><etal/></person-group> <article-title>A low-resource oxygen blender prototype for use in modified bubble CPAP circuits</article-title>. <source>J Med Device</source>. (<year>2020</year>) <volume>14</volume>(<issue>1</issue>). <pub-id pub-id-type="doi">10.1115/1.4045899</pub-id></citation></ref>
<ref id="B29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wu</surname><given-names>AG</given-names></name><name><surname>Luch</surname><given-names>S</given-names></name><name><surname>Floersch</surname><given-names>JR</given-names></name><name><surname>Keester</surname><given-names>A</given-names></name><name><surname>Slusher</surname><given-names>TM</given-names></name><name><surname>Fischer</surname><given-names>GA</given-names></name><etal/></person-group> <article-title>A low-resource oxygen blender prototype for use in modified bubble CPAP circuits: results from design feasibility workshops</article-title>. <source>Am J Trop Med Hyg</source>. (<year>2022</year>) <volume>107</volume>(<issue>3</issue>):<fpage>724</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.4269/ajtmh.22-0091</pub-id><pub-id pub-id-type="pmid">35895338</pub-id></citation></ref>
<ref id="B30"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shinta Devi</surname><given-names>NLP</given-names></name><name><surname>Wanda</surname><given-names>D</given-names></name><name><surname>Nurhaeni</surname><given-names>N</given-names></name></person-group>. <article-title>The validity of the modified tal score and wang respiratory score instruments in assessing the severity of respiratory system disorders in children</article-title>. <source>Compr Child Adolesc Nurs</source>. (<year>2019</year>) <volume>42</volume>(<issue>sup1</issue>):<fpage>9</fpage>&#x2013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1080/24694193.2019.1577921</pub-id><pub-id pub-id-type="pmid">31192740</pub-id></citation></ref>
<ref id="B31"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daga</surname><given-names>b</given-names></name><name><surname>Joshi</surname><given-names>H</given-names></name><name><surname>Gunjal</surname><given-names>P</given-names></name><name><surname>Mhatre</surname><given-names>S</given-names></name></person-group>. <article-title>An innovative air-oxygen blender for continuous positive airway pressure support in resource-poor locations: a feasibility study</article-title>. <source>J Trop Pediatr</source>. (<year>2016</year>) <volume>63</volume>(<issue>4</issue>):<fpage>269</fpage>&#x2013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1093/tropej/fmw085</pub-id></citation></ref>
<ref id="B32"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hedstrom</surname><given-names>AB</given-names></name><name><surname>Nyonyintono</surname><given-names>J</given-names></name><name><surname>Saxon</surname><given-names>EA</given-names></name><name><surname>Nakamura</surname><given-names>H</given-names></name><name><surname>Namakula</surname><given-names>H</given-names></name><name><surname>Niyonshaba</surname><given-names>B</given-names></name><etal/></person-group> <article-title>Feasibility and usability of a very low-cost bubble continuous positive airway pressure device including oxygen blenders in a Ugandan level two newborn unit</article-title>. <source>PLOS Glob Public Health</source>. (<year>2023</year>) <volume>3</volume>(<issue>3</issue>):<fpage>e0001354</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pgph.0001354</pub-id><pub-id pub-id-type="pmid">36963078</pub-id></citation></ref>
<ref id="B33"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ng</surname><given-names>E</given-names></name><name><surname>Dundek</surname><given-names>M</given-names></name><name><surname>Burke</surname><given-names>TF</given-names></name></person-group>. <article-title>Evaluation of an innovative low flow oxygen blender system for global access</article-title>. <source>Front Pediatr</source>. (<year>2022</year>) <volume>10</volume>:<fpage>981821</fpage>. <pub-id pub-id-type="doi">10.3389/fped.2022.981821</pub-id><pub-id pub-id-type="pmid">36186642</pub-id></citation></ref>
<ref id="B34"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>John</surname><given-names>SC</given-names></name><name><surname>Cheng</surname><given-names>EO</given-names></name><name><surname>John</surname><given-names>SP</given-names></name></person-group>. <article-title>The BCPAP score: five questions to assess the effectiveness of a bubble CPAP circuit</article-title>. <source>J Trop Pediatr</source>. (<year>2020</year>) <volume>66</volume>(<issue>5</issue>):<fpage>542</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1093/tropej/fmaa012</pub-id><pub-id pub-id-type="pmid">32170956</pub-id></citation></ref></ref-list>
</back>
</article>