AUTHOR=Zhao Jiang-Li , Chen Pei-Ming , Zhang Tao , Xie Hao , Zhang Yu-Shu , Ng Shamay S. M. , Mao Yu-Rong , Huang Dong-Feng TITLE=Inter-rater and intra-rater reliability of the Chinese version of the short orientation–memory–concentration test in people with stroke JOURNAL=Frontiers in Rehabilitation Sciences VOLUME=Volume 6 - 2025 YEAR=2025 URL=https://www.frontiersin.org/journals/rehabilitation-sciences/articles/10.3389/fresc.2025.1614305 DOI=10.3389/fresc.2025.1614305 ISSN=2673-6861 ABSTRACT=PurposeThis study aimed to use three statistical methods to investigate the inter-rater and intra-rater reliability of the Chinese version of the Short Orientation-Memory-Concentration Test (C-SOMC) for people who have had a stroke.MethodsForty-four participants (31 men and 13 women) with a mean age of 59.05 ± 10.79 years who have had experienced a single episode of stroke were enrolled in this study. To determine the inter-rater reliability of the C-SOMC, the test was administered to each participant on the same day by two raters (A and B) who each had more than 1 year of work experience. To determine intra-rater reliability, rater B re-evaluated 36 of the 44 participants with the C-SOMC on the subsequent day. Intraclass correlation coefficients (ICCs), paired-samples t-tests, and Bland-Altman plots were used to analyze the inter-rater and intra-rater reliability.ResultsThe evaluation of inter-rater reliability for the total score and item 1, 4, 5, 6, and 3/7 showed respective ICCs of 0.959, 0.918, 1.000, 0.942, 0.905 and 0.913, indicating excellent inter-rater reliability for the C-SOMC. Item 2 had an ICC of 0.796, indicating moderate to good inter-rater reliability. The evaluation of intra-rater reliability showed an ICC of 0.978 for the total score, and respective ICCs of 1.000, 1.000, 1.000, 0.968, 0.973 and 0.929 for the individual items, indicating excellent intra-rater reliability for the C-SOMC. The paired-samples t-test for the C-SOMC showed no statistically significant differences (P > 0.05) between ratings made by two different raters or by the same rater on separate occasions. The minimal detectable change value at the 95% confidence threshold (MDC95) of the SOMC score was found to be 2.14. Bland-Altman plots showed a mean difference of 0.02 and 95% limits of agreement (95% LOA) ranging from −3.86 to 3.90 for the inter-rater measurements and a mean difference of 0.33 and 95% LOA of −2.71 to 3.37 for the intra-rater measurements.ConclusionsThe C-SOMC demonstrated excellent inter-rater and intra-rater reliability when administered to people who have had a stroke. The C-SOMC may be used to screen for cognitive impairment in people who have had a stroke.