REVIEW article

Front. Sens., 14 October 2026

Sec. Biosensors

Volume 7 - 2026 | https://doi.org/10.3389/fsens.2026.1884845

Multimodal wearable biosensors in sports: integrating physical and chemical sensing for performance and health

  • 1. Department of Biomedical Engineering, Faculty of Engineering, Fatih Sultan Mehmet Vakıf University, Istanbul, Türkiye

  • 2. BioriginAI Research Group, Department of Biomedical Engineering, Fatih Sultan Mehmet Vakıf University, Istanbul, Türkiye

  • 3. Biomedical Electronic Design Application and Research Center (BETAM), Fatih Sultan Mehmet Vakıf University, Istanbul, Türkiye

  • 4. Department of Medicinal Plants, Faculty of Agriculture and Natural Resources, Arak University, Arak, Iran

Abstract

Wearable technologies have emerged as essential tools for monitoring athletes’ performance and physiological states in real time. This review systematically examines advances in biosensing and wearable systems for sports applications, highlighting their design, sensing modalities, and integration strategies. Athlete tracking and data acquisition form the foundation for personalized training, injury prevention, and performance optimization. Biopotential sensors, including electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG)/electroneurogram Electroneurography, and biopotential electrodes, provide insights into cardiac, muscular, and neural activity. Physical sensors, such as temperature, piezoresistive, piezoelectric, balance and acceleration, pressure, optical, and galvanic skin response (GSR) sensors, enable real-time assessment of movement, mechanical load, body posture, stress, and environmental interactions. Chemical sensors, including sweat and glucose sensors, facilitate non-invasive metabolic monitoring, supporting hydration and energy management. Integrated and hybrid biosensor systems combine multiple sensing modalities, offering comprehensive real-time feedback and personalized analytics for athletes. Despite these advances, challenges remain in sensor miniaturization, power efficiency, data accuracy, wireless communication, and user comfort. Future directions focus on artificial intelligence-driven data analysis, flexible and durable materials, multi-modal integration, and fully personalized wearable platforms. Collectively, wearable biosensing technologies present a transformative approach to sports monitoring, enabling enhanced performance evaluation, injury prevention, and long-term health management.

Graphical Abstract

Highlights

  • Wearable systems enable real-time physiological and biomechanical monitoring in sports.

  • Biopotential sensors provide critical insights into cardiac, muscular, and neural activity.

  • Physical sensors accurately quantify movement dynamics, mechanical loads, and thermal responses.

  • Chemical biosensors facilitate non-invasive metabolic monitoring via sweat biomarker analysis.

  • Flexible nanomaterials ensure high sensitivity and durability during dynamic movements.

  • Hybrid platforms combine diverse sensing modalities for holistic athlete assessment.

  • These technologies drive data-driven injury prevention and performance optimization strategies

1 Introduction

The human body continuously generates a wide range of physiological and biochemical data as a result of complex biological processes. These data include electrical signals, pressure, flow, resistance, temperature variations, and chemical compositions, all of which provide valuable information about an individual’s health status and physical performance. Such vital parameters can be measured through electrical, mechanical, and chemical sensing techniques, forming the foundation of modern biosensing technologies. With rapid advancements in sensor design, signal processing, and material science, wearable technologies have emerged as powerful tools for continuous, real-time, and non-invasive monitoring of the human body.

In recent years, wearable technologies have become increasingly integrated into daily life and have found widespread applications in healthcare, manufacturing, education, security, and sports. Among these fields, sports monitoring has gained particular attention due to the growing demand for performance optimization, injury prevention, and personalized training strategies. Wearable systems enable athletes and coaches to monitor physiological responses, biomechanical movements, and recovery processes under real-world conditions rather than laboratory settings. Consequently, these technologies contribute to data-driven decision-making and evidence-based training programs.

For wearable devices used in sports applications, several critical design requirements must be met. These include flexibility, mechanical durability, lightweight structure, and user comfort, as well as the ability to conform to the curved and dynamic geometry of the human body during movement. In addition, materials used in wearable systems should be non-irritating and biocompatible to ensure long-term use. Equally important is the accurate and reliable acquisition of physiological and biomechanical signals under motion-induced artifacts, sweat, and environmental variations, which remain major technical challenges in wearable sports technologies.

The evolution of enabling technologies such as the Internet of Things (IoT), fifth-generation (5G) communication networks, artificial intelligence (AI), flexible and stretchable electronics, and smart materials has significantly accelerated the development of wearable systems. IoT connectivity allows wearable devices to transmit large volumes of physiological data to cloud-based platforms, while 5G technology enables low-latency and high-speed data transfer. Furthermore, AI and machine learning algorithms facilitate advanced data analytics, pattern recognition, and predictive modeling, transforming raw sensor data into meaningful insights for athletes and sports professionals.

Today, physiological and activity-related data can be collected through a wide range of wearable devices, including smartwatches, smartphones, smart glasses, earphones, and sensors integrated into textiles and garments. These systems offer numerous advantages, such as remote monitoring, seamless integration with daily accessories, personalized data collection, and ease of use in both professional and amateur sports environments (Seçkin et al., 2023). From an economic perspective, the global wearable technology market was valued at approximately $84.2 billion in 2024 and is projected to reach $186.14 billion by 2030, corresponding to a compound annual growth rate (CAGR) of 13.6% between 2026 and 2030 (Aguilar-Torán et al., 2023). This rapid growth reflects the increasing adoption of wearable technologies and highlights their commercial and societal importance.

As illustrated in Figure 1, wearable technology provides a fundamental framework for innovation across a wide range of application areas, including health, fitness, aging, rehabilitation, and intelligent data-driven systems (Shen et al., 2024). In sports-related applications, wearable physiological signal monitoring technologies reduce the need for bulky equipment, minimize space and infrastructure requirements, and lower operational costs. Moreover, they eliminate time-consuming procedures associated with traditional monitoring methods and enable continuous data acquisition without interrupting training or competition (Dahiya et al., 2024). Despite these advantages, challenges related to sensor accuracy, long-term stability, power consumption, data integration, and privacy protection remain critical issues that must be addressed. A structured literature search was conducted in PubMed, Web of Science, Scopus and Google Scholar for publications from 2000 to 2026. Keywords covered wearable biosensors, multimodal sensing, sensor fusion, artificial intelligence, machine learning and sports applications. Studies addressing athlete monitoring, performance, activity recognition, injury prevention or rehabilitation were included, whereas duplicates, irrelevant studies and those with insufficient methodological information were excluded. Records were screened by title and abstract, followed by full-text assessment of eligible studies.

FIGURE 1

This review aims to provide a comprehensive and structured overview of advances in biosensing and wearable technologies for sports applications. The focus is placed on athlete tracking, physiological, biomechanical, and biochemical sensing modalities, and the integration of multimodal and hybrid biosensor systems. Establishes its novelty by departing from these isolated hardware compilations to present a unified system-level perspective on multimodal sensor integration. Rather than treating physical, biopotential, and electrochemical sensors as independent technologies, this work critically examines the engineering challenges of co-locating these diverse modalities on a single, skin-compliant substrate. We specifically analyze the signal processing pipelines required to synchronize high-frequency kinetic streams with lagged chemical sweat kinetics, the hardware-level power gating strategies necessary to operate under strict battery-sizing limits, and the RF attenuation issues caused by sweat-induced antenna impedance shifts. Finally, this review introduces the emerging role of interstitial fluid (ISF) microneedle platforms as a metabolic tracking method capable of bridging the critical rest-to-exertion monitoring gap—a dimension entirely absent from traditional sweat-centric reviews. Additionally, current challenges and future research directions are discussed to support the development of next-generation wearable technologies for sports monitoring and performance optimization.

2 Wearable technologies for sports monitoring

Sporting activities involve a wide range of complex and dynamic movements, including running, jumping, climbing, swimming, lifting, throwing, striking, turning, and physical collisions (Valchinov et al., 2014). Monitoring these movements and the associated physiological responses is essential for understanding athletic performance, training efficiency, and injury mechanisms. In this context, wearable technologies have introduced a paradigm shift in sports monitoring by enabling continuous, real-time, and field-based data acquisition.

The adoption of wearable technologies has significantly transformed training methodologies, competition analysis, and post-event performance evaluation in both individual and team sports. Devices such as smartwatches and fitness wristbands are widely used by amateur and individual athletes, whereas professional athletes increasingly rely on advanced wearable systems, including textile-integrated sensors. These technologies provide real-time information on performance indicators such as heart rate, distance covered, speed, acceleration, and muscle activity. By continuously tracking these parameters, athletes and coaches can fine-tune training programs, monitor progress, and make data-driven adjustments to improve performance outcomes (Rong et al., 2021).

Beyond performance enhancement, wearable technologies play a critical role in injury prevention and risk assessment. By identifying early indicators of fatigue, biomechanical imbalance, and muscle overload, wearable systems enable the detection of potential injury risks before they lead to serious conditions. This predictive capability supports the design of personalized training and recovery programs tailored to the physiological needs of individual athletes. Furthermore, wearable technologies facilitate effective management of recovery, rest, and rehabilitation processes, which are essential for maintaining long-term athletic performance.

In sports and fitness applications, wearable sensors have become widely adopted tools for monitoring training load, physiological stress, and movement patterns. The integration of physiological sensors with motion sensors provides a comprehensive representation of an athlete’s physical condition and performance state (Di Giminiani et al., 2020). Such multimodal sensing approaches enhance the accuracy and reliability of performance assessments, particularly in high-intensity training environments.

In Olympic and combat sports, including boxing, fencing, judo, karate, taekwondo, wrestling, and running, the analysis of movement dynamics, energy expenditure, and health conditions is of paramount importance. During performance monitoring, a variety of sensors, such as gyroscopes, three-axis accelerometers, magnetic field sensors, pressure sensors, and body temperature sensors, are employed to capture detailed biomechanical and physiological data (Lynn et al., 2018; Li et al., 2022). These sports are associated with a high risk of pain, injury, and fatigue. Muscle fatigue, in particular, is commonly linked to the accumulation of lactic acid, hydrogen ions, and phosphates within muscle tissue. The assessment of muscle fatigue is frequently performed using electromyography (EMG) signals in combination with inertial measurement unit (IMU) data.

The application of wearable technologies extends beyond elite athletes to include recreational users and non-professional populations. For example, Cindy Gray et al. demonstrated that wearable devices combined with coaching support can be effectively used to promote weight loss and healthy lifestyle behaviors among male soccer fans with a body mass index of 27 and above, as well as individuals aged between 35 and 65 (Verdel et al., 2021; Goods et al., 2023; Hashimoto et al., 2025). This highlights the broader potential of wearable sports technologies for health promotion and population-level monitoring.

2.1 Tracking of athletes

The potential of technology to enhance sports performance has been widely recognized in both individual and team sports. Wearable devices and sensor-based systems enable continuous monitoring of athletes’ biometric, physiological, and biomechanical data, thereby supporting performance optimization and evidence-based training strategies. However, the high cost of advanced wearable technologies may limit their accessibility for smaller sports clubs. In addition, the effective interpretation and practical application of collected data depend largely on the technological expertise and experience of sports scientists and coaches (Pham et al., 2020).

Wearable technologies have been successfully implemented across various sports disciplines, including basketball, baseball, football, rugby, and motorsports, with the aim of improving athletic technique, tactical decision-making, and training efficiency. These systems have also demonstrated significant potential in predicting and reducing injury risks by identifying early indicators of fatigue, overuse, and biomechanical imbalance (Zhang et al., 2024a). In team sports, wearable devices are widely used to monitor players’ on-field movements, providing coaches with detailed real-time data to optimize team strategies and enhance individual performance. For example, in professional football and rugby, parameters such as player speed, endurance, workload, and spatial positioning are continuously analyzed during training and competition (Hunt et al., 2019).

Athlete tracking is essential for accurately identifying performed activities and designing appropriate training programs. By determining the type, intensity, and duration of physical activities, wearable systems support the development of personalized training regimens and allow for objective evaluation of athletic performance. Moreover, wearable devices facilitate health monitoring by tracking biometric parameters such as heart rate, blood oxygen saturation, blood pressure, and step count. Devices such as smartwatches and wearable electrocardiogram (ECG) systems enable early detection of potential health issues and support preventive healthcare strategies in sports environments (Hirata et al., 2021).

In addition to wearable sensor-based systems, video- and vision-based tracking technologies have gained increasing attention in sports analytics. These systems allow for the monitoring of athlete movements without the need for direct physical contact. Kanav Vats et al. developed a video-based player tracking system using convolutional neural networks (CNNs) to identify and track players during hockey competitions, achieving an accuracy of 94.5% (Qin et al., 2025; Zhang et al., 2024b). Such approaches demonstrate the growing role of artificial intelligence in automated athlete tracking and performance analysis.

Inertial measurement units (IMUs) are compact sensors capable of measuring acceleration, angular velocity, and gravitational forces, making them suitable for tracking movement dynamics such as changes in speed, direction, and posture. Samet et al. demonstrated that movement performance can be effectively monitored using IMU-supported video-based systems (Choudhry et al., 2020). Similarly, Wang et al. employed microelectromechanical system (MEMS) motion sensors combined with traditional video analysis to evaluate the skill levels of volleyball spikers, highlighting the effectiveness of sensor-assisted tracking systems for technique assessment and skill enhancement (Yang et al., 2023).

Seçkin et al. (Seçkin et al., 2023) present a comprehensive review of wearable technologies used in sports, focusing on the fundamental concepts, technical challenges, and future prospects of wearable systems for athletic monitoring. The study highlights how advances in sensor miniaturization, flexible electronics, and wireless communication have enabled continuous monitoring of physiological and biomechanical parameters during sports activities. In addition, the authors discuss challenges such as data reliability, sensor integration, user comfort, and long-term stability, which remain critical barriers to large-scale adoption. This work provides a foundational framework for understanding the current landscape of sports wearable technologies and serves as a valuable reference for contextualizing recent developments in biosensing-based wearable systems.

2.2 Athletes’ data

Athlete data will be a major factor in enhancing the experience by gamifying training sessions using augmented reality and virtual reality, especially in gym workouts. When collecting data, sensors are placed not only on the athlete but also on the materials used. Sensors are added to the balls used, the shoes worn, gloves, and auxiliary materials to obtain information about the athlete (Wu et al., 2021).

In the study conducted by Youn et al., the utilisation of wearable patches placed in the palm of the hand, employing virtual reality (VR) and augmented reality (AR) technologies, facilitates movement without direct contact. This is achieved through the utilisation of a dielectric elastomer actuator, which provides pressure and guidance. The potential for this initiative lies in its capacity to offer training opportunities in sporting activities that necessitate additional equipment, including but not limited to table tennis, golf, and tennis (Wang et al., 2018).

Aguilar-Torán et al. (Aguilar-Torán et al., 2023) introduce a sweat-based wearable sensing platform designed to enhance the monitoring of athletes’ physiological and biochemical states. Their work focuses on the detection of sweat-derived biomarkers that reflect hydration levels, metabolic activity, and physical exertion during exercise. The study highlights the advantages of sweat as a noninvasive biofluid for continuous monitoring and demonstrates how wearable sweat sensors can provide meaningful real-time data related to athletic performance. This research reinforces the growing importance of chemical biosensors in wearable sports technologies and their potential to support data-driven performance optimization.

3 Biosensors used in wearable sports technologies

The human body generates a wide range of physiological, biomechanical, and biochemical signals during physical activity, including electrical signals, pressure, motion, temperature variations, and chemical changes. In sports environments, continuous monitoring of these parameters provides valuable insights into athletic performance, training load, fatigue, and injury risk (Zhao et al., 2021). Wearable biosensors enable the real-time acquisition of such data under dynamic conditions, offering a non-invasive and field-deployable solution for sports monitoring.

Sensors are fundamental components of wearable technologies, as they convert physical, chemical, or biological energy into electrical signals that can be processed and analyzed (Guo et al., 2018; Kim et al., 2021). Over the past decade, significant advancements in sensor and processor technologies have led to the development of miniaturized, low-power, and highly sensitive wearable sensors (Yu et al., 2021). These improvements have facilitated the widespread adoption of wearable biosensors in sports applications, allowing continuous monitoring of athletes’ physiological conditions and biomechanical performance during training and competition (Hashimoto et al., 2025).

In wearable sports technologies, sensors are used not only to assess general health parameters but also to evaluate sport-specific performance metrics such as strength, speed, acceleration, endurance, and movement efficiency (Pham et al., 2020). Depending on the application and the level of invasiveness, wearable biosensors can be classified as non-invasive, contacting, minimally invasive, or invasive devices (Zhang et al., 2024a; Hunt et al., 2019). Among these, non-invasive and contacting sensors are most commonly used in sports due to their safety, comfort, and suitability for long-term monitoring.

Wearable biosensors can be broadly categorized into biopotential signal sensors, physical sensors, and chemical sensors. Biopotential sensors, such as electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG), and electrooculography (EOG), measure the electrical activity generated by the heart, muscles, brain, and eyes, respectively. These sensors are widely used in sports to monitor cardiovascular function, muscle activation patterns, neuromuscular fatigue, and cognitive or mental states during performance.

Physical sensors represent one of the most widely used sensor categories in wearable sports technologies. These include temperature sensors, piezoresistive and piezoelectric sensors, accelerometers, gyroscopes, inertial measurement units (IMUs), pressure sensors, and optical sensors such as photoplethysmography (PPG). Physical sensors enable the monitoring of body temperature, motion dynamics, posture, gait, balance, and blood oxygen saturation, all of which are critical for performance analysis and injury prevention in sports environments.

Chemical sensors, particularly sweat-based sensors, have recently gained attention in wearable sports technologies due to their ability to provide real-time biochemical information. Sweat sensors allow the non-invasive measurement of biomarkers such as glucose, lactate, pH, electrolytes, and hydration levels, offering valuable insights into metabolic state, fatigue, and physiological stress during exercise (McLaren et al., 2010; Kaiqiang and Xingyang, 2020). Although traditionally used in laboratory settings, advances in flexible and wearable chemical sensors have enabled their integration into sports garments and skin-mounted platforms.

The advancement of wearable biosensor technologies is driven by improvements in sensor performance, data acquisition capabilities, and wireless communication technologies. However, challenges such as sensor variability, signal noise, power consumption, and data management remain significant obstacles (Di Giminiani et al., 2020). Managing multiple sensors within wearable systems requires reliable data transmission through technologies such as Bluetooth, Wi-Fi, and 5G, enabling real-time data transfer to cloud-based platforms for storage and analysis. An overview of commonly used sensor types in wearable sports technologies, including their measured parameters, operating ranges, and applications, is summarized in Tables 1, 2.

TABLE 1

Sensor typeWearable implementationMeasurment RangeSensing AccuracyResponse timeApplicationRef.
Biopotential Signal Sensors
ECGAdhesive chest patches, smart straps, textrode-integrated garments0,5–4 mVHeart signal and beat control, heart rate(Li et al., 2015)
EMGCompression athletic sleeves, smart training leggings, skin adhesive arrays0,1–5 mV RMS resolutionMuscle signal analysis(He et al., 2020)
EEGElastic athletic headbands, smart caps, behind-the-ear patches5–300 uV resolutionMood, sleep tracking​
ERGSmart contact lenses, bioelectronic eyewear frames0–900 uV resolutionMood, sllep(Liang et al., 2021)
Physical Sensors
Temperature and HumiditySmartwatch backing plates, epidermal bands, skin patches32 °C–40 °C to Body temperature monitoring​
PiezoresistiveCompression knee pants, glove finger inserts, smart tennis rackets50–400 mN of full scaleMonitoring blood pressure(Oweis et al., 2018)
PiezoelectricSelf-powered joint straps, tendon bands, active footwear soles9.8 N/kg Dynamic force shiftHeart rate, respiratory rate, skeletal muscle movement, weight tracking, gait(Liaqat et al., 2022)
(Kumar et al., 2023)
AccelerometerWatch casings, chest-worn vests, clip-on training podsUp to ± 16 g resolutionMotion and direction detection, step counting(Xu et al., 1996)
GyroscopeWristbands, smart glasses, protective headgearUp to resolutionMotion tracking, rotation direction(Wu et al., 2024)
IMUChest harness vests, limb straps, shoe gait podsVariable İntegrated tiltMovement, turning, direction tracking and navigation(Messina and Giardi, 2025; Tang et al., 2024)
PressureCompression leggings, footwear insoles, athletic glovesBlood pressure, blood pressure, respiratory monitoring(Chen et al., 2026)
PPGSmartwatches, optical athletic rings, ear-integrated budsVariable
HR,
The amount of oxygen in the blood, heart rate(Vinoth et al., 2021)
Chemical Sensors
Sweat SensorEpidermal microfluidic patches, localized wrist straps10-µm-100 nm>95% correlation with bloodGlucose, lactate, pH, Hydration and stress measurement(McLaren et al., 2010; Kaiqiang and Xingyang, 2020)
pHMultimodal sweat patches, temporary skin tattoos4–9 pH unitsdrug-free electrical treatments(Chen et al., 2025)
Biosensors
Wearable ISFPlaced on the upper arm or abdominal areaCGM

CLM
Continuous Glucose (CGM), Continuous Lactate (CLM), Cortisol Levels(Luan et al., 2025)

Sensor types used in wearable devices.

TABLE 2

Electrode typeComponentApplicationsEnvironmentRef
Ag/AgClINA116, LMP7721​unshielded “noisy” lab room(Luan et al., 2025)
Ag/AgClAD8323ECG, EMGa room without a noise source(Pei et al., 2025)
Ag/TiSchiller AR12+ECGNormal enviroment (Rest, motion)(Özkahraman et al., 2025)
UCDE (Ag, Au)​ECG, EMG,sweat​(Zhong et al., 2024)
TiO2 - Al2O3LMC6442, INA118ECGControlled environment(Seshadri et al., 2019)
BC/PANI/AgNO3​ECGNoisy environment(Bi et al., 2023)
 AgCF-SADS1293​Lab environment(Ju et al., 2023)
 (MWCNT)/(PDMS)​ECGLab environment, skin(Horita and Ishiko, 1987)
PEDOT-PVA​sEMGLab environment, during sports(Gorostiaga et al., 2012)

Electrode studies used in articles.

3.1 Biopotential signal sensors

3.1.1 Electrocardiography (ECG)

Shen et al. the performance of custom-designed 3D knitted silver electrodes for electrocardiogram (ECG) signal acquisition was investigated and compared with conventional Ag/AgCl electrodes within a wearable smart garment system. Impedance measurements demonstrated that the 3D knitted silver electrodes exhibited significantly lower impedance under wet skin conditions compared to dry conditions, motivating further evaluation of their ECG sensing capability. ECG signals were recorded using both electrode types under identical single-lead configurations and processed with standardized filtering techniques, including high-pass, low-pass, and notch filters. The results showed that although the ECG signals obtained from the 3D knitted silver electrodes exhibited a slightly higher noise level than those recorded using Ag/AgCl electrodes, they maintained clear waveform characteristics. The calculated signal-to-noise ratio (SNR) of 6.95 dB indicates that the proposed electrodes provide reliable ECG signal acquisition. These findings highlight the potential of 3D knitted silver electrodes as a viable and effective solution for wearable ECG monitoring applications, particularly in sports and long-term health monitoring systems (Shen et al., 2024).

In this study Dahiya et al. (2024), recent advances in non-invasive, sensor-based wearable electrocardiogram (ECG) technologies are reviewed with a focus on their applicability to continuous cardiac monitoring in both clinical and sports-related contexts. Growing demand for wearable ECG systems capable of measuring heart rate and heart rate variability (HRV) across diverse populations, including athletes and physically active individuals, has driven the development of multi-channel, biosensor-based devices. The reviewed studies evaluated the performance of wearable ECG systems such as chest straps, wristbands, adhesive patches, and smart textile garments in terms of signal accuracy, quality, comparability, and long-term safety. While challenges related to signal noise, device accuracy, privacy, and prolonged use remain, reported findings indicate minimal adverse effects and acceptable performance during extended monitoring.

Valchinov et al. (2014), a wireless wearable ECG system based on dry-contact electrodes is presented for real-time cardiac monitoring. The system integrates coin-sized dry electrodes that can operate either in direct contact with the skin or through clothing and can be embedded into comfortable textile layers. ECG signals are acquired with a bandwidth of 1–150 Hz and amplified with a differential gain of 56 dB, digitized using a 10-bit ADC, and transmitted via ultra-low-power ANT + wireless technology. The results indicate that the proposed system is well suited for continuous ECG monitoring in home, clinical, and sports environments, particularly for integration into wearable chest-strap applications.

3.1.2 Electromyography (EMG)

Di Giminiani et al. (2020) developed a wearable system based on surface electromyography (sEMG) for monitoring muscle activity. The system is designed to continuously and in vivo measure muscle activity under resting and dynamic exercise conditions. This wearable electronic garment allows monitoring of muscle contraction levels, activation patterns, and fatigue indicators. The developed sEMG system was evaluated by comparing it with two commercial gold standard EMG devices; measurement accuracy and reliability were analyzed using Bland–Altman agreement analysis. The results showed that the proposed wearable EMG system reliably measures muscle activity and exhibits high agreement with commercial systems. These findings demonstrate that wearable EMG-based biopotential sensors are an effective tool for monitoring athlete performance, assessing strength and endurance, and analyzing functional muscles in different populations.

In this study Lynn et al. (2018), the reliability and validity of the Athos® wearable surface electromyography (sEMG) system were evaluated by comparison with a research-grade sEMG system. Twelve healthy participants completed seven testing sessions on separate days, including one baseline trial and six repeated trials. The Athos system, which integrates sEMG electrodes into compression sports garments, was assessed during isokinetic knee flexion and extension tasks performed at multiple angular velocities (60, 180, and 300°/s) and contraction intensities (50%, 75%, and 100% MVC). Muscle activity was recorded from the vastus lateralis, vastus medialis, and biceps femoris muscles. sEMG amplitude metrics, including peak amplitude, integrated linear envelope, and the 95th percentile, were calculated and time-aligned for both systems. The results demonstrated no significant differences between the wearable and research-grade systems in terms of amplitude metrics or the relationship between sEMG activity and torque output. Reliability analysis showed comparable variability between systems across trials and contraction conditions. These findings indicate that the Athos wearable system provides reliable and valid sEMG measurements consistent with research-grade instrumentation, supporting its applicability for sports-related muscle activity monitoring.

3.1.3 Electroencephalogram (EEG)/Electroneurogram (ENG)

Electroencephalography (EEG) is a non-invasive biopotential sensing technique used to record the electrical activity of the brain via electrodes placed on the scalp. EEG signals reflect the collective postsynaptic potentials of large populations of neurons and provide valuable information related to cognitive state, mental workload, fatigue, stress, and sleep patterns. In the context of wearable technologies, EEG has gained increasing attention due to its potential for real-time monitoring of neural activity during daily life and physical activity. Unlike clinical EEG systems, wearable EEG devices prioritize portability, comfort, and long-term usability, often employing dry or textile-based electrodes integrated into headbands, caps, or smart garments.

In sports and exercise applications, wearable EEG systems are primarily utilized to assess mental fatigue, attention, stress levels, and neurocognitive responses to physical exertion. Monitoring brain activity during training and competition can provide insights into an athlete’s cognitive performance, decision-making ability, and psychophysiological state, which are critical factors influencing overall performance. Recent studies have demonstrated that wearable EEG devices can reliably capture changes in neural oscillations associated with fatigue and exertion, enabling objective assessment of training load and recovery status. However, motion artifacts, signal noise, and electrode–skin interface stability remain significant challenges, particularly during high-intensity or dynamic sports activities.

Electroneurography (ENG), which records electrical activity from peripheral nerves, has more limited application in wearable sports technologies due to its technical complexity and susceptibility to motion-related interference. Nevertheless, advancements in flexible electrodes, signal processing algorithms, and miniaturized electronics are gradually improving the feasibility of wearable EEG and ENG systems. As these technologies continue to evolve, wearable neural monitoring is expected to play an increasingly important role in sports performance optimization, injury prevention, and mental state assessment within intelligent training and athlete monitoring systems.

3.1.4 Biopotatial electrode

To advance widespread biopotential monitoring, it is essential to develop low-cost, rapidly deployable, low-noise electrodes in combination with compact electronics and wireless technologies. Once such systems are implemented, electrical activity generated by physiological processes within the human body can be continuously monitored without the need for cumbersome application or maintenance procedures (Luan et al., 2025).

Biopotential electrodes function as transducers that convert electrical biological signals produced by the body into electron flow. These signals are measured as a potential difference between two electrode sites. Biopotential electrodes enable the acquisition of various physiological signals, including ECG, EMG, EEG, and ERG. It should be noted that the frequency and amplitude characteristics of the recorded signals may vary depending on the type of biological activity being measured.

Li et al. (2022) developed a sweat-tolerant biopotential electrode based on conical microporous Janus gold nanowire/nitrocellulose (AuNWs/NC) structures was developed to address skin–electrode interface challenges in wearable electrophysiological monitoring. Inspired by directional fluid transport mechanisms in nature, the Janus AuNWs/NC electrode enables spontaneous sweat transfer from the skin-facing AuNW side to the nitrocellulose layer, thereby maintaining conformal skin contact and low interfacial impedance during prolonged measurements. The electrode was integrated with circuit modules and advanced signal-processing algorithms to achieve real-time visualization of muscle activity intensity. The proposed system demonstrates stable and high-fidelity acquisition of electrophysiological signals under sweating conditions, supporting accurate assessment of muscle controllability and balance. These results highlight the potential of the Janus AuNWs/NC biopotential electrode for long-term wearable applications in sports training, health monitoring, and human–computer interaction.

Electrodes are divided into two groups based on their materials. These are further divided into polarized and non-polarized electrodes (Kim et al., 2021; Chen et al., 2024). Polarized electrodes: These are electrodes that restrict current flow between the electrolyte and the electrode material. These electrodes act as capacitors. Non-polarized electrodes: These are electrode types that allow current flow. During oxidation and reduction, depending on the maintenance of equilibrium, a voltage drop occurs when current flows due to the potential difference, i.e., the half-cell potential. These types of electrodes are generally the most commonly used silver/silver chloride electrodes in the industry. They are also preferred because they are easy and inexpensive to produce.

Despite their high temporal resolution, wearable biopotential systems face severe signal degradation during dynamic athletic movements. The primary bottleneck stems from the skin-electrode interface: wet hydrogel electrodes suffer from dehydration during prolonged endurance events, driving rapid impedance spikes, whereas dry conductive polymer or textile electrodes exhibit high baseline contact resistance. Motion-induced shear forces cause micro-displacements at the stratum corneum interface, generating high-amplitude motion artifacts that overlap with the frequency spectra of ECG and EMG signals. Furthermore, surface EMG acquisition suffers from signal cross-talk from adjacent muscle groups and spatial orientation sensitivity, while dynamic EEG monitoring remains heavily constrained by a low signal-to-noise ratio, where facial muscle contractions and head accelerations frequently swamp microvolt-level neural potentials.

3.2 Physical sensors

Physical sensors are essential components of biosensing and wearable technologies for sports, enabling continuous and non-invasive monitoring of physiological and biomechanical parameters. These sensors convert physical stimuli into electrical signals to support real-time data acquisition during athletic activities. In this context, temperature, piezoresistive, and piezoelectric sensors are used to assess thermal responses and mechanical forces, while balance, acceleration, and pressure sensors provide information on motion, stability, and load distribution. Optical and galvanic skin response (GSR) sensors further contribute to the evaluation of physiological states and stress-related responses.

3.2.1 Temperature measurement

Physical sensors for temperature measurement are essential components of wearable sports technologies, enabling non-invasive monitoring of thermoregulatory responses. These sensors support real-time assessment of heat stress and athlete safety, particularly during exercise in challenging environments (Tenan et al., 2011). For example, in this study, Verdel et al. (2021) evaluated the validity and reliability of a non-invasive wearable sensor (CORE, greenTEG, Switzerland) for monitoring core body temperature during exercise were evaluated under different thermal conditions. Two experimental protocols were conducted in controlled laboratory environments involving male participants exposed to low-to-moderate and moderate-to-high heat stress during cycling exercise. Core body temperature measured by the CORE sensor was compared with rectal temperature as the reference standard. The results demonstrated acceptable reliability between repeated trials; however, the agreement between CORE-derived and rectal temperatures was limited, with approximately half of the paired measurements exceeding the predefined validity threshold. Overall, the findings indicate that although the CORE sensor shows acceptable reliability, it does not provide sufficiently valid measurements of core body temperature during exercise.

Goods et al. (2023), the concurrent validity of a wearable temperature sensor (CORE) for assessing core body temperature during exercise in hot conditions was evaluated against a reference telemetric temperature pill (BodyCAP). Nineteen elite female field hockey players completed four heat-training sessions, during which core temperature was continuously monitored using both devices. Agreement between the sensors was assessed using Lin’s concordance correlation coefficient and bias analysis. The results demonstrated poor agreement across all sessions, with the CORE device consistently underestimating core temperature, particularly at higher temperature values, and a substantial proportion of measurements exceeding the predefined agreement threshold of ±0.3 °C. Overall, these findings indicate that the CORE sensor does not provide sufficiently valid measurements to replace telemetric temperature pills during exercise in hot environments.

Hashimoto et al. (2025), a compact and user-friendly wearable multimodal sensor probe to enable real-time monitoring of core body temperature under heat stress conditions. The system integrates a heat flux–based temperature sensor with additional physiological measurements to simultaneously assess core temperature, cardiac activity, and sweat rate during exercise. Validation experiments conducted with healthy adult males performing cycling exercise under controlled environmental conditions demonstrated high accuracy, with a root mean square error of 0.087 °C for core body temperature. Although the system tended to overestimate core temperature and sweat rate during exercise and recovery due to thermoregulatory responses, the results indicate that the proposed wearable sensor represents a practical and comprehensive solution for temperature monitoring and heat stress prevention in sports and other physically demanding activities.

Pham et al., an integrated wearable sensing platform is presented for non-invasive, continuous monitoring of physiological responses under heat stress conditions. The system combines physical sensors to measure skin temperature, heart rate, oxygen saturation, physical activity, and galvanic skin response within a compact and user-friendly wearable device. Using a low-power microcontroller, the platform enables on-device data integration and continuous storage for over 48 h, making it suitable for real-world and ambulatory applications. The device was validated against clinical reference standards, including infrared thermometry and fingertip pulse oximetry, demonstrating high accuracy and strong correlation. These results highlight the potential of wearable temperature-based physical sensing technologies to support personalized health monitoring, enhance safety during physical activity in hot environments, and advance biosensing solutions for sports and mobile health applications (Figure 2A) (Pham et al., 2020).

FIGURE 2

Hunt et al. (2019), the agreement between heart rate–derived estimated core body temperature (ECTemp) and directly measured gastrointestinal temperature was evaluated during repeated work–recovery cycles while wearing explosive ordnance disposal protective clothing. Eight male participants completed controlled treadmill walking sessions under moderate and hot environmental conditions. The results demonstrated minimal systematic bias and acceptable limits of agreement between estimated and measured temperatures up to 38.5 °C. These findings indicate that heart rate-based temperature estimation provides a practical and non-invasive approach for monitoring heat strain and supporting safety during physically demanding activities in thermally stressful environments.

Hirata et al. (2021) proposed a non-invasive method for predicting changes in body core temperature using heart rate and environmental conditions within a simplified thermodynamic model. The two-layered, two-compartment model showed good agreement with core temperature increases measured under both bare and clothed conditions. The results suggest that vital signals from wearable devices can support effective heat stress management in daily life and in occupational or athletic settings by enabling accurate and real-time prediction of core temperature.

In summary, wearable temperature sensors play a critical role in sports by enabling non-invasive and continuous monitoring of thermoregulatory responses. These technologies support heat stress management and athlete safety during training and competition. Ongoing advancements in sensor design and data processing are enhancing their accuracy and real-world applicability.

3.2.2 Piezoresistive sensors

Piezoresistive sensors have emerged as a technology in wearable devices for sports applications, enabling the real-time monitoring of biomechanical signals such as pressure, force, and movement to enhance athletic performance and prevent injuries. Sensors are devices that convert mechanical (physical) force into corresponding electrical signals (Jansen et al., 1997). For example, in this study, Kim et al. conceived the design of a wearable piezoelectric film sensor with the objective of monitoring blood pressure within the range of 50–400 mN (Oweis et al., 2018). Qin et al., a flexible piezoresistive sensor based on a CB-PPy-KH560/SR composite to enable real-time monitoring of biomechanical parameters associated with intensive athletic training. The sensor exhibits stable and repeatable electrical responses under tensile strains ranging from 5% to 30%. At an optimized filler content of 10 phr, the sensor reliably recovers its baseline resistance upon strain release, demonstrating its capability to track dynamic pressure variations during movement. This piezoresistive sensing approach provides effective real-time biomechanical feedback, contributing to improved training assessment and reduced risk of sports-related injuries (Qin et al., 2025).

Zhang et al. (2024b), a flexible piezoresistive pressure sensor (FPPS) based on an MXene–melamine sponge composite for wearable evaluation of tennis performance. The sensor is designed to monitor grip-pressure dynamics during four fundamental tennis strokes, forehand, backhand, serve, and volley, in both training and competition settings. Pressure-related parameters, including pressure duration, peak pressure, and timing characteristics, are extracted and analyzed using artificial intelligence algorithms. The results reveal significant differences in grip-pressure timing metrics between elite and intermediate players, while peak pressure shows no significant variation. The system achieves high recognition accuracy, demonstrating that flexible piezoresistive sensors enable reliable, real-time biomechanical assessment and hold strong potential for performance optimization and injury prevention in wearable sports technologies.

Choudhry et al. (2020) explore the use of stitching as a scalable fabrication technique for developing wearable piezoresistive sensors in e-textile applications. By varying stitch patterns and yarn lengths, the effects on sensor sensitivity, operating range, and response time are systematically evaluated, while reproducibility is ensured through repeated fabrication and testing. The sensors demonstrate stable performance under incremental pressures up to 14 kPa and maintain durability over 3,000 cyclic loading cycles. When integrated into garments, the sensors successfully detect subtle biomechanical signals, including respiratory rate and step count, and retain their functionality after multiple washing cycles. Overall, the results highlight the strong potential of low-cost, flexible, and highly sensitive stitched piezoresistive sensors for diverse wearable sensing applications.

Zhang et al. investigates the evaluation of sports performance based on grip pressure using a flexible piezoresistive pressure sensor (MMSS) composed of MXene as the sensing material and melamine sponge as the substrate. Grip pressure patterns of expert and amateur athletes were analyzed across various sports activities and technical transitions using time- and pressure-related indicators. The collected data were processed and classified using artificial intelligence–based algorithms, enabling accurate differentiation of performance levels, particularly in tennis training scenarios. The results demonstrate that flexible piezoresistive sensors offer an effective and practical solution for wearable sports performance assessment and biomechanical monitoring (Figure 2B; Zhang et al., 2024a).

Yang et al. (2023) developed a smart tennis racket equipped with flexible piezoresistive sensors composed of MXene and melamine sponge (MMSS) to quantitatively assess grip force, impact, and motion during training. The sensors demonstrated high sensitivity (5.35 kPa−1 for 1.1–22.2 kPa and 0.6 kPa−1 up to 266 kPa) and accurately captured five typical stroke types. Integrated AI algorithms achieved a classification accuracy of 98.2% for distinguishing stroke behaviors. This system enables comprehensive monitoring of tennis techniques, supports performance improvement, and provides a framework for intelligent motion detection, highlighting its potential for sports big data collection and Internet of Things (IoT) applications.

Wu et al. (2021) investigated a wearable wrist-mounted sensor platform integrated with a smartphone and computer for real-time tennis stroke classification and performance assessment. Data collected from a single low-cost MEMS sensor were transmitted via Bluetooth and analyzed using machine learning algorithms. Twelve elite right-handed male tennis players each performed 150 strokes. Stroke recognition and classification involved preprocessing, segmentation, feature extraction, and classification using Support Vector Machine (SVM) with and without Min–Max and Z-score normalization, as well as K-Nearest Neighbors (K-NN) and Naive Bayes (NB) algorithms. Ten-fold cross-validation was applied during training to prevent overfitting, and optimal parameters were determined for the SVM classifiers. The highest test accuracy was achieved using SVM with an RBF kernel (C = 1) and Min–Max normalization, reaching 99%, while SVM with Z-score normalization achieved 98.4%. These results demonstrate that the proposed wearable piezoresistive/MEMS sensor system can reliably classify individual stroke types and provide precise performance feedback in real-time athletic settings.

In summary, piezoresistive sensors offer a versatile and reliable approach for wearable sports devices, providing real-time monitoring of biomechanical signals that can enhance performance assessment and injury prevention.

3.2.3 Piezoelectric sensors

Piezoelectric sensors are used to measure physical changes such as mechanical force, pressure, acceleration, vibration, sound, or voltage. The applied physical forces cause dielectric polarization. Piezoelectric charges accumulate positive and negative charges in opposite directions (Jansen et al., 1997; Liaqat et al., 2022).

Recent studies have demonstrated the potential of piezoelectric pressure sensors for wearable health monitoring applications. For instance, Wang et al. (2018) electrospun poly (vinylidene fluoride–trifluoroethylene) composites reinforced with carbon nanotubes have been reported to exhibit enhanced electromechanical performance, combining high flexibility, mechanical robustness, and sensitivity. Such sensors can detect subtle physiological signals, including pulse, respiration, and small-scale muscle and joint movements such as swallowing and finger motion. The improved piezoelectric response is mainly attributed to polymer chain alignment and the promotion of the electroactive β-phase, highlighting the suitability of piezoelectric composites for self-powered and highly sensitive wearable sensing platforms.

Zhao et al. (2021) developed a flexible, self-powered piezoelectric sensor based on poly (vinylidene fluoride) thin films for real-time monitoring of sport-related motion without the need for external power. This sensor can be attached directly to the skin or joint regions to detect sequences of movement, such as limb extension and joint compression, during activities like basketball shooting. The design harnesses mechanical energy generated during motion to produce a piezoelectric signal, enabling detection of force order, angle changes, and motion frequency. Such self-powered and wearable designs demonstrate the potential for integrating piezoelectric sensing modules into sports performance tracking and rehabilitation monitoring systems, contributing to non-invasive, continuous biomechanical assessment in athletic contexts (Figure 3A).

FIGURE 3

Guo et al. (2018) developed a wireless wearable motion monitoring system based on a piezoelectric pressure sensor fabricated from electrospun PVDF/BaTiO3 nanocomposite fibers. The proposed device integrates a piezoelectric sensing layer with signal acquisition, amplification, data conversion, and Bluetooth-based wireless transmission modules, enabling real-time visualization of motion data on a mobile platform. The system demonstrated high sensitivity to dynamic human movements, including squatting, walking, and running, highlighting its capability to capture biomechanical patterns associated with both daily activities and sports exercises. Such piezoelectric-based wireless sensing platforms represent a promising approach for continuous motion monitoring in rehabilitation programs and sports medicine applications.

3.2.4 Balance and acceleration sensors

Balance and acceleration sensors constitute a core component of wearable systems used for sports performance assessment and rehabilitation monitoring, as they enable precise quantification of human motion and postural stability. By capturing kinematic parameters such as joint angles, movement trajectories, acceleration profiles, and gait patterns, these sensors provide objective insights into movement quality, coordination, and functional recovery. In both athletic training and post-injury rehabilitation, balance- and acceleration-based measurements support the evaluation of range of motion, symmetry between limbs, and temporal characteristics of motion, allowing continuous and real-time monitoring outside clinical environments. Consequently, wearable inertial sensing technologies play a crucial role in injury prevention, performance optimization, and data-driven training strategies in modern sports applications (Liu et al., 2025; Djassemi et al., 2026).

Wearable physical sensors enable continuous and non-invasive monitoring of biomechanical and physiological parameters that are critical for both rehabilitation and sports performance assessment. By being integrated into garments or positioned on sensitive skin locations, these systems provide objective and real-time feedback that exceeds the limitations of conventional clinical and training-based evaluation methods. Among the monitored parameters, joint range of motion (ROM) represents an indicator of functional recovery and movement quality, as it quantitatively describes joint mobility through angular displacement relative to defined reference planes or axes.

In this context, Kim et al. (2021) investigated upper-limb joint kinematics using wearable motion sensors to quantify movements such as wrist flexion–extension, radial–ulnar deviation, shoulder rotations, forearm pronation–supination, and elbow flexion–extension. The measured joint angles were further employed to reconstruct patient-specific movements through real-time avatar-based visualization, enhancing the interpretability of rehabilitation progress. In addition to absolute joint angles, the comparison between the mobility of injured and healthy limbs enabled the assessment of movement frequency and daily limb utilization, providing insight into functional recovery (Figure 3B).

Beyond upper-limb analysis, lower-limb joint angles, particularly at the knee and ankle, have been identified as essential parameters for injury prevention and gait assessment. Metrics such as initial contact angle, maximum joint angle during mid-stance, and the temporal delay between these events vary with running duration and footwear type, and can be used to evaluate biomechanical efficiency. Similar sensing approaches are also applied in sports performance monitoring, where ROM, movement intensity, acceleration, and physiological signals such as heart rate and respiration rate contribute to assessing fatigue, technique execution, and overall athletic condition. These findings highlight the central role of wearable physical sensors in delivering quantitative, objective, and application-oriented insights for both rehabilitation and sports contexts.

3.2.5 Pressure sensors

The measurement of pressure sensors is typically determined by the alteration in resistance that occurs in response to the external force applied to the sensor. Strain gauges and Wheatstone bridges are instrumental in the fabrication of pressure sensors (Wu et al., 2021; Yin et al., 2024). In the domain of sports, it facilitates the measurement of numerous parameters, including step counting, foot pressure, change of direction speed, acceleration time, and departure from the initial position (Assalve et al., 2024). For example, In this study, Yu et al. (2021) removable flexible pressure sensors were integrated into compression sports leggings to enable real-time monitoring of three-dimensional forces acting on the knee joint during exercise. The leggings were structurally optimized to provide appropriate lower-limb compression, aiming to protect the knee joint and improve exercise efficiency. The reliability of the flexible pressure sensors was validated by comparison with an AMI3037-5s airbag pressure tester, showing no significant differences based on F-values and t-test probabilities greater than 0.05. Physiological measurements indicated that oxygen saturation and total hemoglobin levels in the legs increased after exercise, suggesting effective fatigue relief. Body surface temperature changed steadily during exercise and gradually decreased afterward, demonstrating good thermal and moisture comfort performance. These results confirm the potential of flexible pressure-sensing technology for smart wearable applications in sports and health monitoring.

McLaren et al. (2010), a wearable wireless dynamic pressure monitoring system to measure garment pressure during sports activities characterized by large anthropometric changes in the limbs. The system incorporated six low-profile pressure sensors with a diameter of 18 mm, positioned at the calf, thigh, and hip regions to detect pressures in the range of 5–50 mmHg. The accuracy and sensitivity of the device were evaluated using stepwise pressure changes generated by applying known masses, and the results were compared with those obtained from Kikuhime™ and PicoPress™ reference systems. Additional tests were conducted to assess the system’s ability to track pressure variations between the garment and the body during various physical activities. The performance of the wearable device was analyzed in terms of portability, dynamic response, accuracy, sensitivity, resolution, and usability. Overall, the system was found to be suitable for advanced field studies aimed at characterizing dynamic and gradient compression in sports garments.

Kaiqiang and Xingyang (2020), a high-performance flexible pressure sensor capable of real-time monitoring of physiological signals and human motion during sports activities was developed. A porous polydimethylsiloxane (PDMS) foam fabricated using a sacrificial template method and graphene as the conductive filler was employed to achieve a wide pressure sensing range of 0–100 kPa with ultra-high sensitivity. The sensor exhibited an average sensitivity of 17.9 kPa-1 in the 0–30 kPa range and up to 79 kPa-1 in the 30–100 kPa range, along with a fast response time of 20 m and stable performance over more than 10,000 loading cycles. The excellent sensing performance was attributed to the high elastic modulus of the porous PDMS foam and the optimized graphene loading. The sensor was demonstrated to accurately detect subtle physiological signals, including pulse and electrocardiogram signals, as well as vocalization and facial expressions. In addition, complex joint and limb movements such as bending, walking, squatting, running, and jumping were reliably monitored in real time, highlighting the sensor’s potential for wearable sports monitoring and coaching applications (Figure 4A).

FIGURE 4

Li et al. carbonized cotton (CC) with moderate electrical conductivity was prepared from cotton via a simple pyrolysis process and used as a conductive scaffold for flexible pressure sensing. Flexible and electrically conductive CC/PDMS composites were fabricated by vacuum-assisted infusion of PDMS resin into the CC framework. Based on these composites, a simple yet highly sensitive pressure sensor was developed, exhibiting a maximum sensitivity of 6.04 kPa-1, a wide operating pressure range of up to 700 kPa, a response frequency from 0.01 to 5 Hz, and durability over more than 1,000 loading cycles. The pressure sensitivity of the CC/PDMS sensor is comparable to or higher than many previously reported pressure sensors. Integration of the sensor into sports shoes and a waist belt demonstrated its capability for real-time monitoring of sports performance and health conditions. Owing to its simple, scalable fabrication process and low-cost cotton precursor, the CC/PDMS composite shows strong potential for wearable electronics in sports performance and health monitoring applications (Figure 4B; Li et al., 2015).

In summary, recent advances in flexible and wearable pressure sensor technologies have enabled accurate, real-time monitoring of mechanical forces during sports activities, offering valuable insights for performance optimization, injury prevention, and health monitoring in next-generation smart sportswear and wearable systems.

3.2.6 Optical sensors

Optical sensors play a critical role in wearable sports technologies by enabling non-invasive, high-sensitivity monitoring of mechanical and physiological parameters through light-based sensing mechanisms (Jansen et al., 1997; Akinin et al., 2020; Sun and Yu, 2016; Chi et al., 2009). For example, in this study, He et al. (2020) developed an optical fiber-based humidity sensor to monitor relative humidity (RH) changes in real time during physical exercise. The sensor consists of a fiber end coating produced by layer-by-layer bonding of poly (allylamine hydrochloride) and silica nanoparticles, while an uncoated fiber section is used to compensate for bending losses due to body movement. The sensing system exhibited a linear RH response and low hysteresis with a sensitivity of 3.02 mV/% (R2 = 0.96) when an optimized number of double layers was applied. Real-time RH measurements were performed on ten healthy volunteers using two different textile materials: 100% cotton and 100% polyester. The results revealed the superior moisture absorption behavior of polyester, as demonstrated by a faster decrease in post-exercise RH compared to cotton. These findings highlight the potential of optical fiber humidity sensors to guide wearable sports performance monitoring and functional sportswear design and optimization.

Liang et al. (2021) developed a self-propelled optical strain sensor based on the integration of mechanical luminescence phosphors with an elastic optical fiber. The sensor emits light only in response to mechanical strain, eliminating the need for external light sources or electrical power. Strain-induced luminescence is efficiently collected and directed along the optical fiber, enabling linear strain detection up to 50% with ±1% accuracy. The device exhibits excellent durability, performing stably through more than 10,000 stretch-relaxation cycles. Reliable operation is ensured under both bright and dark conditions thanks to the superior light-directing capability of the elastic optical fiber. These results demonstrate the powerful potential of self-propelled optical strain sensors for continuous, wearable sports monitoring and next-generation smart wearable systems.

In summary, optical sensor technologies provide robust, non-invasive, and energy-efficient solutions for real-time monitoring in wearable sports systems, supporting continuous performance assessment, injury prevention, and the development of next-generation smart sportswear.

3.2.7 GSR sensors

Galvanic skin response (GSR) sensors are widely employed in wearable biosensing systems to assess physiological stress and hydration-related responses. These are sensor systems that detect stress and measure hydration in wearable technologies (Park et al., 2025; Palumbo et al., 2021). GSR, an acronym for galvanic skin response, is a method for measuring the electrical conductance of the skin. Sweat secretion by the sweat glands can be triggered by strong emotional states, which activate the sympathetic nervous system. This physiological mechanism forms the basis for the functionality of lie detectors (Acar et al., 2019). Electrodermal activity (EDA) is one of the most important methods for measuring stress using galvanic skin response (GSR) (Hwang et al., 2019). Stress can be measured through the integration of various physiological indicators, including but not limited to heart rate, movement speed, blood pressure, skin tension, perspiration, and blood oxygen levels. GSR constitutes only one of these available methods.

Oweis et al. (2018) used wearable sensors to investigate human emotional and psychological states through galvanic skin response (GSR) measurements. A Microsoft Band two device continuously collected GSR data from nineteen engineering students enrolled in the same course over an academic semester. Participants were categorized according to their weekly activity levels, as determined by an online self-report questionnaire. One-way analysis of variance and correlation analyses were performed to examine differences and relationships between GSR values ​​and activity levels. The results revealed significant within-group differences and significant correlations between GSR measurements and activity levels. These findings demonstrate that wearable GSR sensors can also be effectively applied in monitoring psychophysiological responses related to physical activity and sports participation.

Liaqat et al. (2022) proposed a non-invasive and effective hydration monitoring system based on galvanic skin response (GSR) to accurately predict hydration levels in the human body. Wearable GSR data was collected under three hydration conditions (hydrated, mildly dehydrated after 8 h, and significantly dehydrated after 16 h) and in three body positions, including sitting, standing, and walking. Eight machine learning algorithms and four deep learning models were trained and evaluated using the collected GSR signals. A hybrid machine learning and deep learning model was developed to further improve prediction accuracy. The hybrid Bi-LSTM model achieved a high prediction accuracy of 97.83% in classifying hydration states. These results highlight the potential of wearable GSR-based hydration monitoring systems to support sports performance, athlete safety, and health management during physical activities.

In this summary, galvanic skin response (GSR) sensors are highlighted as wearable physical sensing technologies that enable non-invasive assessment of stress, hydration, and psychophysiological states by measuring skin conductance, thereby supporting health monitoring and performance evaluation in sports and activity-oriented applications. While inertial and strain sensors are commercially mature, their integration into continuous athletic tracking reveals critical mechanical and algorithmic trade-offs. Strap-down IMUs inherently suffer from numerical integration drift, causing cumulative orientation and displacement errors during unconstrained, long-duration tracking. Additionally, soft-tissue motion—the relative displacement between the skin-mounted sensor and the underlying skeletal bone—introduces non-linear mechanical noise (soft-tissue artifacts) that distorts impact force estimates in collision sports. For flexible piezoresistive and piezoelectric strain sensors, hysteresis, slow elastic recovery, and viscoelastic relaxation under continuous cyclic deformation result in signal drift and non-linear sensitivity profiles, compromising measurement repeatability during high-frequency physical exertion.

3.3 Chemical sensors

Electrochemical sensors are utilised for the purposes of diagnosis and detection due to their simple structure, small size, ease of production, and high performance (Yang and Hsu, 2010). Chemical sensors are a type of sensor that enables the analysis of chemical substances (biomarkers) within fluids in the human body (Jansen et al., 1997).

3.3.1 Sweat sensor

Sweat has been identified as a biomarker that can be obtained from specific parts of the body during movement or at rest (Manjarres et al., 2020; Abdul-Hussain et al., 2023) The composition of this fluid encompasses a range of chemical elements, including sweat, urea, uric acid, sugar, lactic acid, amino acids, and ammonia. It is noteworthy that the concentrations of these components can exhibit significant inter-individual variability. The pH value of sweat is generally approximately 5.5 (Leu et al., 2018). Sweat intensity and, consequently, electrodermal activity (EDA) are high in areas such as the fingers, palms, soles of the feet, armpits, back, and forehead (McLaren et al., 2010).

The phenomenon of perspiration is subject to variation in accordance with a number of factors, including gender, age, race, genetics, environmental influences, and the individual’s exercise status. The analysis of an athlete’s sweat values during exercise and training is of paramount importance. It is feasible to undertake periodic measurements of lactate, urea, stress, glucose levels, muscle fatigue, hydration, and water requirements. Sweat analytes include sodium, chloride, potassium, glucose, lactate, bicarbonate, ammonia, cortisol, and amino acids (Angelucci et al., 2021).

Electrochemical sweat-based lactate sensing represents one of the most extensively investigated approaches in wearable sports biosensing due to the strong correlation between lactate concentration and physical exertion. Enzymatic detection strategies typically rely on lactate oxidase (LOx) or lactate dehydrogenase (LDH), which catalyze the conversion of lactate into electrochemically detectable products. LDH-based systems benefit from high enzymatic stability and have demonstrated wide detection ranges without the need for external redox mediators, whereas LOx-based sensors commonly use mediators such as Prussian blue to enhance signal transduction.

Kumar et al. (2023) reported an electrochemical sweat-based lactate biosensor that operates without the need for an external redox mediator, achieving a broad detection range from sub-millimolar to high millimolar concentrations. Their approach employed lactate dehydrogenase immobilized on a modified screen-printed carbon electrode using carbodiimide-based crosslinking chemistry, enabling stable enzymatic activity at the electrode interface. In contrast to mediator-assisted systems, this strategy reduces circuit complexity; however, as with other enzyme-based lactate sensors, signal linearity remains sensitive to environmental factors such as pH and temperature. Variations in these parameters can alter enzymatic kinetics, particularly in lactate oxidase-based systems, where optimal catalytic performance is confined to a narrow pH window. These limitations highlight the importance of integrating auxiliary sensing modalities or compensation strategies to ensure reliable lactate monitoring in wearable sports applications.

Previous studies have demonstrated that the performance of lactate oxidase–based electrochemical biosensors is highly sensitive to variations in the chemical environment of sweat. Xu et al. (1996) reported that lactate oxidase exhibits optimal catalytic activity within a narrow pH window, with peak performance around physiological pH, while deviations toward acidic or alkaline conditions result in a rapid decline in enzymatic efficiency. Such pH fluctuations may arise during electrochemical lactate detection due to redox reactions that locally alter proton or hydroxyl ion concentrations. These findings highlight a limitation of enzyme-based sweat sensors in dynamic sports conditions and emphasize the importance of integrating auxiliary sensing elements, such as pH and temperature sensors, to enable real-time compensation and improve the reliability of lactate monitoring in wearable sports technologies.

The pH level of a healthy athlete is typically between 4.5 and 6.5, however, in individuals diagnosed with cystic fibrosis, this pH level can increase to a level greater than 9. It is imperative to maintain the pH level within the designated ranges to ensure optimal health (Bi et al., 2023; Tan et al., 1992). Despite their high sensitivity, enzyme-based lactate sensors are inherently affected by environmental factors, particularly pH and temperature, which can significantly alter enzymatic activity and compromise signal linearity. Previous studies have shown that LOx exhibits optimal activity within a narrow pH window, highlighting the need for complementary sensing strategies to compensate for physiological fluctuations in sweat composition during exercise. To address this limitation, Wu et al. (Wu et al., 2024) proposed a multifunctional electrochemical platform capable of simultaneously monitoring lactate concentration and temperature. Their system integrates lactate oxidase within a chitosan matrix on flexible nanoporous gold electrodes, which not only increases the effective electrode surface area but also creates a nanoconfined environment that enhances catalytic efficiency and reduces substrate inhibition (Figure 5A). Such integrated sweat-sensing platforms offer a promising route toward reliable, real-time metabolic monitoring for sports performance assessment and fatigue management (Messina and Giardi, 2025).

FIGURE 5

Lactate analysis in sweat is linked to low oxygen levels. However, lactate concentrations in blood and sweat differ significantly. The accumulation of lactic acid in muscle tissue decreases ATP production, which ultimately leads to muscle fatigue (Liu et al., 2026). It is imperative that the sensor functions with the requisite sensitivity (i.e., −12.5 ± 0.53 nA mM-1) to ensure the accurate measurement of lactate in sweat within the expected range of 1–20 mM (Cömert et al., 2013). It is imperative to acknowledge the fact that the measurement of lactate levels is susceptible to variations in temperature and pH values.

It is known that the human body is approximately 70% water. The percentage of water in the human body varies according to criteria such as gender, age, and whether the individual is young or old. Hydration refers to the process of the body distributing water adequately and evenly (Zhang et al., 2014). Hydration measurement can be achieved using body weight, fluid, urine, blood tests, and bioelectrical impedance electrodes (Butkeviciute et al., 2019; Al-S and heikh, 2023; Park et al., 2025).

Hydration is a vital component of skin health. The measurements are obtained through the assessment of fluctuations in the ionic composition of the skin. The measurement of these values is facilitated by the use of impedance values. An increase in the ionic value of the skin is indicative of elevated hydration levels (Tenan et al., 2011). It is evident that an increase in the magnitude of the electric potential leads to a concomitant decrease in the impedance value. This facilitates the measurement of the hydration level of the skin. The measurement of hydration levels in the human body can be achieved through the analysis of perspiration and saliva.

Dehydration is a condition in which the body becomes excessively dehydrated. Athletes, the elderly, heavy laborers, and soldiers are at risk of dehydration if they do not consume enough water (

Al-S and heikh, 2023

). The phenomenon of dehydration in athletes has been demonstrated to result in a number of deleterious consequences, including but not limited to.

  • -

    An overall decrease in performance

  • -

    The onset of health problems

  • -

    An elevated risk of death, should the issue be disregarded As indicated by the literature, health complications arising from dehydration encompass a range of symptoms, including but not limited to heat stroke, fatigue, cramps, and elevated body temperature (Butkeviciute et al., 2019).

A hormonal imbalance in the body can be caused by stress, which is bad for your health (We et al., 2008). The adrenal gland secretes cortisol, a steroid hormone that is regulated by the hypothalamic-pituitary-adrenal axis (Chowdhury et al., 2019; Kulkarni et al., 2024). This axis plays an extremely important role in human physiological processes. Changes in the body’s stress can be effectively understood by monitoring cortisol secretion in sweat, and the state of mental stress can be regulated as a result (De Fazio et al., 2023).

Recent advances in wearable sweat sensing have enabled simultaneous monitoring of multiple physiologically relevant biomarkers. A flexible self-powered sweat biosensor system was developed for real-time, in situ monitoring of glucose, K+ and Na+, using triboelectric sensor arrays with interpenetrating double-network hydrogel electrodes. The system maintained stable electrical outputs under varying mechanical stimuli and achieved sensitivities of 2.34, 0.037 and 0.046 V mM-1 for glucose, K+ and Na+, respectively. Wireless integration further enabled threshold-based alerts and personalized feedback, demonstrating the potential of multiplexed sweat sensing for real-time monitoring under dynamic conditions relevant to sports performance and personalized health (Chen et al., 2026).

Extending this multiplexed sensing capability, Vinoth et al. developed a screen-printed microfluidic sensing platform for real-time electrochemical monitoring of lactate, Na+, K+ and pH during exercise. The integrated microfluidic channel rapidly collected and transported sweat to the sensing electrodes within 40 s, while a miniaturized potentiostat enabled selective and interference-free signal acquisition with wireless transmission. The fully integrated, pump-free device was demonstrated during stationary cycling, highlighting the feasibility of real-time multiplexed sweat analysis under exercise conditions and its potential for sports monitoring (Vinoth et al., 2021).

Beyond multiplexed analyte detection, emerging biorecognition strategies are expanding the selectivity and stability of wearable sweat sensors. Chen et al. developed a wearable electrochemical sensor based on molecularly imprinted polymer (MIP) technology for real-time and dynamic monitoring of cortisol in sweat. The flexible sensor exhibited a broad detection range from 0.1 pM to 5 μM, high selectivity against potential interferents and stable performance over 120 cycles. A silk fibroin/PVDF composite membrane facilitated directional sweat transport, while the flexible electrode design reduced mechanical interference during wearable operation. The sensor response closely followed the daily cortisol rhythm in human sweat, demonstrating the potential of MIP-based wearable sensing for selective and continuous biomarker monitoring (Chen et al., 2025).

Aptamer-based recognition has similarly emerged as a promising strategy for improving molecular selectivity. Luan et al. developed aptamer-functionalized multivalent fluorescent DNA nanostructures (Ap-MFDNs) to enhance the detection of cortisol, lactate and uric acid in sweat. The multivalent binding strategy improved detection sensitivity compared with monovalent probes, with particularly pronounced enhancement for cortisol. The resulting wearable sensors covered the physiological concentration ranges of these biomarkers and enabled direct detection in human sweat with smartphone assistance. These findings highlight the potential of aptamer-based multivalent DNA nanostructures as selective biorecognition elements for wearable and multiplexed sweat monitoring (Luan et al., 2025).

In parallel, advanced nanomaterials are providing new opportunities to enhance sensor sensitivity and operational stability under dynamic conditions. Chen et al. developed a PyTS-functionalized Ti3C2Tx MXene-based wearable electrochemical sensor for non-invasive and real-time monitoring of uric acid in human sweat. The PyTS@Ti3C2Tx interface enhanced the electrocatalytic activity towards uric acid oxidation, enabling sensitive detection over a concentration range of 5–100 μM with a detection limit of 0.48 μM. Integrated with flexible microfluidic sweat sampling and wireless electronics, the sensor enabled real-time uric acid monitoring during aerobic exercise. This study highlights the potential of MXene-based nanomaterials to enhance the sensitivity and practical applicability of wearable sweat sensors under dynamic exercise conditions (Chen et al., 2024).

Complementing MXene-based approaches Pei et al. developed an enzyme-free wearable potentiometric sensor based on a multiwalled carbon nanotube (MWCNT)/Cu-HHTP metal–organic framework (MOF) composite for continuous sweat lactate monitoring. The incorporation of MWCNTs enhanced the conductivity and electron-transfer efficiency of Cu-HHTP, enabling sensitive lactate detection with a detection limit of 1.09 μM and high sensitivity across physiologically relevant concentration ranges. The sensor also exhibited good reproducibility and stability and enabled continuous monitoring of dynamic changes in sweat lactate during physical exercise. These findings demonstrate the potential of MOF-based nanocomposites to improve the sensitivity, stability and practical applicability of wearable sweat sensors under dynamic conditions (Pei et al., 2025).

Collectively, these advances demonstrate a transition towards multiplexed, selective and nanomaterial-enabled sweat sensing platforms capable of operating under realistic exercise conditions. The integration of multiple biomarkers, MIP- and aptamer-based recognition strategies, and MXene- and MOF-based functional materials provides new opportunities for improving sensitivity, selectivity and stability. Nevertheless, challenges associated with long-term reliability, sensor calibration, interference from complex sweat matrices and validation across diverse exercise conditions remain important considerations for the translation of these technologies into robust wearable sports monitoring systems.

3.3.2 Glucose sensors

The advent of devices capable of measuring blood sugar levels has recently been observed. The measurement of blood glucose levels is achievable through the utilisation of devices that use a minimally invasive procedure, entailing the pricking of the finger to obtain a small blood sample. However, this is an uncomfortable experience and, over time, can have a detrimental effect on the patient’s quality of life due to the formation of holes in the fingers. In the contemporary era, characterised by accelerated technological progress, CGM systems have been developed that facilitate the continuous, round-the-clock measurement of glucose levels. In parallel with implantable CGM systems, wearable glucose biosensors based on non-invasive biofluids have emerged as a promising alternative. These systems provide real-time data on glucose trends, thereby enabling individuals to make informed decisions regarding their health management. These systems generally comprise a diminutive sensor that is positioned subcutaneously in the abdominal region or the upper arm. The sensor in question measures glucose levels in the interstitial fluid (the fluid between cells), and the data is transmitted wirelessly to a display device or a smartphone app. (Anastasiou et al., 2022; Xi et al., 2026). However, with the advancement of wearable sensor technology, there has been a development of blood glucose monitoring devices that can be used for extended periods by diabetic patients. Devices that collect data from subcutaneous body fluid and blood taken from the arm have been developed, enabling long-term use for a period of between seven and 15 days (Lv et al., 2025). The estimation of blood sugar (BS) levels in patients has been demonstrated to play a pivotal role in the prevention of hypoglycaemia and hyperglycaemia (Lim et al., 2026).

Wearable glucose biosensing technologies offer a non-invasive alternative for continuous glucose assessment, which is particularly advantageous for improved glycemic management. In this study, a flexible electrochemical glucose biosensor employing carbon black nanoparticles (CBNPs) was developed for glucose detection in human sweat. The sensing platform integrates CBNPs with Prussian blue as an electron mediator, while glucose oxidase is immobilized within a chitosan–Nafion matrix to ensure enzymatic stability and efficient signal transduction. The resulting biosensor exhibits a wide linear response over the micromolar to millimolar concentration range, combined with high sensitivity and operation at a low applied potential relative to Ag/AgCl. Furthermore, the device demonstrates a low detection limit, along with good reusability, selectivity, and operational stability. Its reliable performance in real sweat samples highlights the suitability of CBNP-based wearable biosensors for non-invasive glucose monitoring applications (Figure 5B) (Tang et al., 2024). Another promising direction involves engineered heterostructure materials such as black phosphorus combined with graphitic carbon nitride, which improve electrocatalytic surface area and charge transfer kinetics for glucose oxidation, and have been integrated into wearable microfluidic platforms enabling continuous sweat glucose monitoring with wireless data transmission. These innovations illustrate the potential of sweat-based glucose biosensing for non-invasive physiological tracking and performance optimization in sports and wellness applications (Özkahraman et al., 2025).

The primary limitation of epidermal sweat biosensors lies in the decoupling between sweat-borne analyte concentrations and systemic blood levels. Sweat rate variability, local skin evaporation, and pH shifts alter enzymatic activity on the electrode surface, introducing severe calibration instability over time. Furthermore, continuous microfluidic sampling faces fluidic latency, where newly secreted sweat mixes with stale residual sweat within the microchannels, diluting transient biomarker spikes during rapid exertion changes. Enzyme-based electrochemical substrates (e.g., lactate oxidase) also experience rapid biofouling due to non-specific protein adsorption and thermal degradation in high-ambient-temperature training environments, severely shortening the operational lifespan of these devices to mere hours.

3.4 Integrated and hybrid biosensor systems

Biosensors are analytical systems that detect data, activity, or signals generated during chemical processes in the human body. These signals are converted into electrical signals through physical or chemical means. (Cuperman et al., 2022; Sun and Yin, 2025). The fabrication of biosensors involves the utilisation of living tissue and cells, including DNA molecules, antibodies, and antigens. These structures are the result of biochemical reactions. In certain instances, physical and chemical sensors are utilised as transducers in the context of biosensor construction. (Guo et al., 2018; Kim et al., 2021). Transducers are sensing elements that facilitate the conversion of non-electrical signals (e.g., force, pressure, temperature) into an electrical signal. The development of biosensors is an outcome of interdisciplinary studies, resulting from the integration of physical, chemical, and biological structures. (Parvin et al., 2025; Cuperman et al., 2022; Yang and Hsu, 2010; Parvin et al., 2025).

Integrated and hybrid biosensor systems play a critical role in next-generation wearable sports technologies by combining sensing, signal processing, power management, and wireless communication within a single platform. In this context, Zhong et al. present a multifunctional microneedle-based wearable patch is presented that integrates an electrochemical sensor array, a rechargeable battery, an embedded circuit board, and Bluetooth-enabled smartphone connectivity (Figure 6Aa,b). This integrated architecture enables continuous, real-time monitoring of multiple physiological biomarkers relevant to athletic performance and metabolic status. The hybrid system incorporates microneedle electrochemical sensors capable of detecting glucose, lactate, and ethanol from interstitial fluid with minimal invasiveness. When applied to the upper arm, the patch remains firmly attached without causing discomfort, ensuring stable signal acquisition during both resting and active conditions (Figure 6Ac). Although sterilization leads to a partial decrease in sensor current response, the system preserves sufficient sensitivity to reliably capture biomarker fluctuations. Calibration using skin-mimicking models prior to application further enhances the accuracy and reproducibility of the electrochemical measurements. Human validation experiments demonstrate the system’s ability to dynamically track metabolic changes induced by nutrient intake, physical exercise, and alcohol consumption. Distinct current increases are observed following glucose ingestion (Figure 6Ad), high-intensity exercise–induced lactate production (Figure 6Ae), and ethanol intake (Figure 6Af). The biocompatible and disposable design of the microneedle array minimizes skin irritation and supports safe, repeated use, as confirmed by epidermal recovery observations. Extended monitoring and scenario-based evaluations further highlight the robustness of this integrated biosensing platform. Long-term measurements reveal stable performance over multiple days, while simulated sports scenarios demonstrate its applicability for monitoring physiological risks during exercise, such as post-alcohol exertion and hypoglycemia prevention. Collectively, these results underscore the potential of integrated and hybrid biosensor systems for advanced, real-time biochemical monitoring in wearable sports technologies (Zhong et al., 2024; Seshadri et al., 2019).

FIGURE 6

Noninvasive biofluids such as sweat, saliva, and urine contain diverse electrolytes and metabolites that provide valuable insights into physiological status and metabolic balance. Variations in electrolyte levels may indicate hydration or ionic imbalance, while metabolite fluctuations are closely associated with metabolic activity, making these biomarkers highly relevant for wearable health and sports monitoring applications. Consequently, significant research efforts have focused on developing wearable sensors capable of dynamically tracking electrolytes and metabolites in noninvasive biofluids. In this context, Bi et al. have introduced a universal fully integrated wearable sensor array (FIWSA) has been introduced to enable multiplexed monitoring of both electrolytes and metabolites across multiple raw biofluids, including sweat, saliva, and urine. Using Na+ and pH as representative electrolytes and uric acid (UA) as a model metabolite, the FIWSA demonstrates versatility by allowing continuous, skin-mounted monitoring during physical activity. During a cycling exercise, real-time changes in sweat Na+, pH, and UA were successfully recorded (Figure 6a-d). A distinct increase in sweat Na+ concentration was observed during prolonged cycling, while sweat pH remained within a stable physiological range. In contrast, uric acid levels exhibited a decreasing trend, likely associated with increased sweat secretion during exercise. Furthermore, the incorporation of tailored calibration strategies for different biofluids significantly improved the accuracy of metabolite detection (Figure 6B e), underscoring the critical role of calibration in integrated and hybrid biosensor systems. These results highlight the potential of fully integrated wearable sensor arrays for comprehensive, real-time biochemical monitoring in sports and personalized healthcare applications (Bi et al., 2023).

Ju et al. (2023) review the application of microfluidic wearable technologies for sports-related sensing, emphasizing their role in real-time biochemical analysis of noninvasive biofluids. The study demonstrates how microfluidic integration enables precise sample handling, reduced contamination, and improved signal stability when monitoring sweat-based biomarkers during physical activity. By combining microfluidic platforms with chemical sensors and wearable electronics, these systems facilitate continuous and on-body analysis of metabolites and electrolytes relevant to athletic performance. This work underscores the importance of microfluidic–sensor integration as a component of hybrid biosensor systems for next-generation sports wearables.

Beyond physical integration, the analytical value of multimodal wearable biosensors depends critically on how heterogeneous signals are temporally aligned, transformed, and fused. Multimodal data fusion can broadly be implemented at the signal-, feature-, or decision-level. Signal-level fusion combines synchronized raw measurements, but is often impractical for wearable sports systems because electrophysiological, mechanical, and biochemical signals differ substantially in sampling frequency, noise characteristics, and physiological latency. Feature-level fusion is therefore particularly attractive: physiologically meaningful descriptors can first be extracted from individual modalities and subsequently concatenated into a multimodal feature space. For example, electromyography (EMG) features such as root-mean-square amplitude, median frequency, or muscle activation patterns can be combined with sweat lactate concentration, heart rate, skin temperature, and motion-derived features to characterize neuromuscular and metabolic states simultaneously. In contrast, decision-level fusion allows each sensing modality to generate an independent physiological estimate, which can subsequently be combined using weighted voting, probabilistic inference, or ensemble learning. This architecture may offer greater robustness to temporary failure or missing data from an individual sensor, although it can also lose interactions between modalities that are informative at the feature level. Consequently, the optimal fusion strategy depends on the physiological question, signal quality, temporal resolution, computational resources, and degree of interindividual variability. Importantly, the presence of multiple sensors on the same wearable platform should not itself be considered multimodal intelligence; meaningful multimodal integration requires the joint interpretation of complementary physiological signals to generate information that cannot be reliably obtained from a single modality.

The potential of multimodal sensing becomes particularly important when biochemical and physiological signals are interpreted as complementary indicators rather than independent measurements. The relationship between lactate dynamics and EMG-derived fatigue features provides an illustrative, yet physiologically complex, example. Previous exercise studies have reported associations between lactate accumulation and changes in surface EMG characteristics during intense muscle contractions (Horita and Ishiko, 1987; Gorostiaga et al., 2012). However, this relationship is not universal: during progressive cycling exercise, Tenan et al. found that changes in EMG median power frequency were not significantly related to blood lactate concentration, indicating that the relationship between biochemical accumulation and electrophysiological fatigue depends strongly on exercise modality, contraction type, muscle state, and the specific EMG feature examined (Tenan et al., 2011). Similarly, earlier work demonstrated that the relationship between EMG spectral changes and lactate accumulation during dynamic exercise cannot be interpreted as a simple causal association (Jansen et al., 1997). These findings highlight why multimodal sensing should move beyond simple correlation and incorporate temporal alignment, exercise context, and individualized modelling. Recent technological developments provide a practical basis for such approaches. For example, a 2025 wearable platform simultaneously integrated flexible EMG electrodes with an electrochemical lactate sensor and demonstrated synchronous acquisition of electrophysiological and biochemical signals, with machine-learning models used to classify physiological states (Liu et al., 2025). In sports-specific applications, continuous interstitial-fluid lactate monitoring has also recently been combined with synchronous heart-rate measurements in collegiate baseball pitchers, where lactate dynamics tracked exercise intensity and metabolic strain during pitching (Djassemi et al., 2026). Such platforms illustrate how multimodal systems could combine neuromuscular, cardiovascular, biochemical, and mechanical information to estimate fatigue more comprehensively than a single biomarker. A progressive increase in EMG-derived fatigue features together with elevated lactate and cardiovascular strain, for example, could provide convergent evidence of increasing physiological load, whereas discordance between modalities may identify situations in which a single-marker interpretation would be misleading. Similar multimodal relationships could be explored between heart rate and lactate for metabolic–cardiovascular strain, IMU-derived mechanical load and EMG for neuromuscular compensation, or sweat electrolytes and skin temperature for hydration and thermal-stress assessment. Ultimately, these cross-modal relationships could support real-time fatigue estimation, individualized training-load adjustment, recovery monitoring, and injury-risk assessment. Nevertheless, reliable prediction requires longitudinal datasets and personalized models that account for interindividual differences, training status, hydration, exercise intensity, modality-specific temporal delays, and sensor uncertainty rather than assuming fixed relationships between individual biomarkers (Yin et al., 2024; Assalve et al., 2024).

3.5 Critical synthesis and comparative analysis of wearable modalities

To effectively deploy wearable platforms in elite sports, a clear understanding of the trade-offs between different sensing modalities is imperative. While physical sensors (e.g., IMUs) offerhigh-frequency data regarding external workload, they cannot directly capture the internal physiological and metabolic strain experienced by the athlete. Conversely, chemical biosensors provide direct molecular insights into hydration and metabolic shifts, but their temporal response and dependence on fluid sampling can limit real-time applications compared with biopotential systems. These comparisons highlight the complementary roles of different sensing modalities in capturing external workload, internal physiological responses and metabolic status in sports monitoring (Tables 3, 4).

TABLE 3

Sensor typeSensing principleMeasured parametersAdvantagesLimitationsResponse timeWearable form factorReferences
BiopotentialIonic–electronic charge transferECG, EMG, EEG; HR, HRV, muscle activationHigh temporal resolution; direct physiological informationMotion artefacts; electrode displacement; baseline driftReal-timeChest straps; textile garments; patches(Akinin et al., 2020; Sun and Yu, 2016; Chi et al., 2009; Park et al., 2025; Palumbo et al., 2021; Acar et al., 2019)
PhysicalPiezoresistive, capacitive or piezoelectric transductionAcceleration, kinematics, impact, temperatureContinuous movement and workload monitoringHysteresis; integration drift; mechanical couplingReal-timeSmartwatches; insoles; compression garments(Hwang et al., 2019; Yang and Hsu, 2010; Manjarres et al., 2020; Abdul-Hussain et al., 2023; Leu et al., 2018; Angelucci et al., 2021)
Chemical/molecularAmperometric or potentiometric transductionLactate, glucose, Na+, K+, pHMetabolic and hydration informationSweat availability; calibration; biofluid transportSeconds–minutesSweat patches; skin-interfaced patches(Bi et al., 2023; Tan et al., 1992; Liu et al., 2026)

Comparison of major wearable sensing modalities for sports monitoring.

TABLE 4

Sensor typeBody RegionArtifical intelligent inputArtifical intelligent ModelMain PurposeData retrieval FrequencyReferences
EEGHead, behind the earRaw EEG signal (0.5–250 Hz)LSTM, GRU, CNNMental fatigue, focus state, stress detectionInstantaneous(Xia et al., 2026; Abbas et al., 2024; Wang et al., 2026; Nemane et al., 2026)
EKGChest, wristRaw EKG signal (200–500 Hz)LSTM, ID-CNNArrhythmia and cardiac stress warning, heart rateInstantaneous(Wang et al., 2025; Gai, 2025; Najafi et al., 2024; Qi and Aliverti, 2020)
EMGLeg and arm musclesRaw EMG signal (100–500 Hz)LSTM, ID-CNNMuscle fatigue score, sudden muscle spasm detectionInstantaneous(Wilk et al., 2021; Yang et al., 2026; Shei et al., 2022)
PPGwristRaw ekg and blood pressure (125 Hz)RNN, CNNheart rate, blood pressure, SPO2Instantaneous(Heydari and Mahmoud, 2025)
GSRWrist, hand, legRaw GSR signal (0.1–1 Hz)ANN, CNNStress level, dehydrationPeriodic(Park et al., 2025; Palumbo et al., 2021; You et al., 2026)
Temperature and HumidityArms, legs, body36,5 °C and %40–50ANNBody temperature change, hydrationPeriodic(Spetz et al., 2025; Ousaka et al., 2022; Hung et al., 2025)
GlucoseSubcutaneous, sweat90–140 mg/dLANN, CNN, RNN, XGBoostHypoglycemia, hyperglycemiaPeriodic(Anastasiou et al., 2022; Lim et al., 2026; Jin et al., 2026; Sirtoli et al., 2023)
Pressure and AccelerationAnkle, knee, waist, chestAcceleratio, angular velocity and position data (2–100 Hz)CNN, LSTM, KNNLoss of balance, falls, shockInstantaneous(Yu et al., 2021; Wang et al., 2021; Nigusse et al., 2021)

Artificial intelligence in wearable technologies.

A cross-modal comparison demonstrates that wearable sensing technologies exhibit distinct trade-offs between temporal resolution, physiological specificity, technological maturity, robustness, and practical suitability. Biopotential sensors, including ECG and EMG, provide direct physiological information with millisecond-to-second temporal resolution and are therefore particularly valuable when rapid changes in cardiovascular or neuromuscular state need to be detected. ECG is relatively mature and is well suited to endurance-oriented activities such as running, cycling, and rowing, where heart rate and HRV provide important indicators of cardiovascular strain and recovery. EMG provides more localized information on muscle recruitment and fatigue and can therefore offer greater value in resistance training, sprinting, and rowing. However, both modalities remain highly dependent on electrode–skin contact and are susceptible to electrode displacement, sweat-induced impedance changes, and motion artifacts during high-intensity activity (Akinin et al., 2020; Sun and Yu, 2016; Chi et al., 2009; Park et al., 2025; Palumbo et al., 2021; Acar et al., 2019).

Physical sensing modalities, particularly IMU-based systems, provide a complementary perspective by quantifying external workload and movement behaviour rather than internal physiological state. Their high sampling rates, relatively low computational requirements, and established MEMS-based hardware have resulted in substantially greater technological maturity and widespread commercial adoption compared with many biochemical wearable sensors (Hwang et al., 2019; Yang and Hsu, 2010; Manjarres et al., 2020; Abdul-Hussain et al., 2023; Leu et al., 2018; Angelucci et al., 2021). IMUs are therefore particularly suitable for dynamic and contact-intensive sports, including football, rugby, basketball, running, and skiing, where acceleration, impact, movement trajectory, and mechanical workload are important performance variables. Nevertheless, IMU-derived measurements can be affected by sensor placement, orientation, integration drift, and mechanical coupling with the body. More importantly, movement measurements alone cannot distinguish whether a given external workload is associated with low or high physiological strain, highlighting a fundamental limitation of purely physical sensing.

Chemical and molecular sensing modalities occupy a different position within this trade-off space. Sweat-based electrochemical sensors can provide information on lactate, glucose, electrolytes, and pH, thereby offering biochemical information that cannot be obtained directly from IMUs or conventional biopotential sensors (Bi et al., 2023; Tan et al., 1992; Liu et al., 2026). This makes them particularly attractive for endurance sports and prolonged training sessions in which hydration, metabolic demand, and fatigue-related biochemical changes are important. However, their practical maturity remains lower than that of IMU and ECG technologies because measurements are affected by sweat availability, sweat rate, sampling location, biofouling, temperature, evaporation, and calibration drift. In addition, biochemical responses generally exhibit slower and biomarker-dependent kinetics than electrical and mechanical measurements because analyte transport and biofluid sampling introduce physiological and analytical delays. Consequently, chemical sensors may be more informative for assessing metabolic state over longer time scales than for detecting instantaneous changes in athletic movement or neuromuscular activity.

Sensor suitability is therefore strongly dependent on the physiological and biomechanical demands of the target sport. High-dynamic and collision-based sports, such as football, rugby, and basketball, primarily benefit from IMUs and ECG because rapid movement, impact, and cardiovascular responses must be captured with high temporal resolution. Endurance activities such as marathon running and cycling may benefit from combining IMU- and ECG-derived external and cardiovascular workload with sweat-based measurements of lactate and electrolytes to provide complementary information on internal metabolic and hydration status. In resistance exercise, EMG can provide muscle-specific recruitment and fatigue information that cannot be inferred reliably from inertial measurements alone. Conversely, precision sports such as archery, shooting, and golf may place greater emphasis on ECG and potentially EEG measurements because autonomic and cognitive states can influence performance despite relatively limited gross movement. These differences indicate that there is no universally optimal wearable sensor; rather, modality selection should be determined by the required temporal resolution, physiological variable, expected movement intensity, duration of monitoring, environmental conditions, and acceptable calibration burden.

A major challenge across wearable modalities is maintaining signal quality under the high-motion and variable conditions of athletic environments. Biopotential signals are particularly susceptible to motion artifacts during dynamic movements, with electrode–skin contact pressure and interface mechanics strongly influencing signal quality. Studies on textile electrodes have shown that appropriate control of electrode pressure and compliant interfacial materials can reduce motion artifacts, although their effectiveness depends on the mechanical properties of the interface and applied pressure (Cömert et al., 2013).

Beyond interface-level optimization, signal-processing approaches provide an additional means of mitigating motion-related interference. Motion artifacts remain a major challenge for wearable physiological monitoring during dynamic exercise. Adaptive filtering can reduce motion-induced interference; however, its effectiveness varies across physiological signals and movement conditions, highlighting the need for signal-specific artifact compensation strategies (Zhang et al., 2014). Multimodal artifact correction can further improve signal reliability by using a physiological signal such as ECG as a reference for motion-artifact removal from EEG recordings, demonstrating the potential of cross-channel processing in real-time wearable systems (Butkeviciute et al., 2019).

This principle can be extended to the integration of physical and physiological sensing modalities. Multimodal integration may therefore improve signal interpretation by using inertial measurements to identify movement-related artifacts and contextualize physiological signals. Accelerometer-assisted adaptive filtering, for example, has been shown to suppress motion artifacts in PPG while maintaining accurate heart-rate estimation with low computational complexity (Al-S and heikh, 2023). A wrist-worn PPG/ACC sensor integrating a three-axis MEMS accelerometer was developed to reduce motion artifacts during movement. An adaptive filter based on a fast cross-RLS algorithm improved the stability and reliability of PPG signals during typical arm movements while reducing computational complexity, demonstrating the potential of accelerometer-assisted artifact correction for wearable cardiovascular monitoring (We et al., 2008).

Importantly, these approaches can provide measurable improvements in sensing performance and real-time applicability. An adaptive filtering–RNN architecture was developed for real-time heart-rate estimation from motion-contaminated PPG signals. The approach achieved a mean absolute error of 0.98 beats min-1 on the IEEE 2015 Signal Processing Cup dataset, outperforming several existing methods and demonstrating robustness for real-time wearable monitoring (Chowdhury et al., 2019).

Collectively, these findings indicate that motion robustness depends not on a single sensor or processing strategy, but on the interaction between interface design, signal-processing methods and complementary sensing modalities. Thus, multimodal architectures that combine physiological and inertial information offer a promising route towards reliable real-time wearable monitoring in dynamic sports environments.

4 Challenges and future directions of wearable technologies in sport

4.1 Technical challenges and current bottlenecks

The utilisation of artificial intelligence has become pervasive, permeating all facets of human existence. In consequence of recent developments, its utilisation in all areas remains unabated. The acquisition of athlete data is predominantly facilitated by wearable technologies during sporting activities, competitive events, and training regimens. However, the interpretation of this data is challenging. This is due to the instantaneous or periodic nature of the data, which renders its tracking and interpretation a laborious process. By measuring recorded health values and athlete performance and using artificial intelligence, the data is rendered comprehensible and athletes are protected from future injuries, ailments, illnesses, etc. The primary objective of incorporating artificial intelligence within the domain of sports pertains to the implementation of preventative measures aimed at mitigating the risk of injuries to athletes, in addition to facilitating expeditious recovery in the event of such occurrences (Heydari and Mahmoud, 2025).

Recent interest has been observed in the field of deep learning approaches for a variety of problems, including image analysis, artificial intelligence, and sensor computing. In the field of deep learning, features are automatically abstracted from data as opposed to being manually created. This enables the more effective use of these machine learning methods in various classification tasks. The present study investigates the potential of deep learning approaches, including Deep Belief Networks (DBN), Restricted Boltzmann Machines (RBM), and Convolutional Neural Networks (CNN), in the development of more generalised learning methods that facilitate the direct extraction of features from input data (Kei et al., 2025).

Human activity recognition (HAR) systems have a significant impact on machine learning. Reading, processing, analyzing, and storing data with the help of sensors has become a useful field. Developments in telemedicine have made medical care more accessible to patients in rural or isolated areas (Oloko-Oba et al., 2026).

Kulkarni et al. (2024) review recent advances in smart wearable sensors for continuous human health monitoring, with implications for sports and physical activity tracking. The authors discuss the integration of sensing elements, data processing units, and wireless communication modules into compact wearable platforms capable of long-term operation. Challenges such as power consumption, sensor accuracy, data interpretation, and user compliance are also addressed. This work provides important insights into the technological limitations and future research directions of smart wearable systems, supporting the discussion on scalability and real-world deployment of wearable biosensors in sports applications.

De Fazio et al. (2023) investigate the role of smart gadgets and wearable sensor technologies in monitoring sports performance and rehabilitation metrics. Their study provides an overview of how wearable sensors and smart devices can continuously capture physiological and biomechanical data during both training and recovery phases. By integrating wearable sensing technologies into sports rehabilitation workflows, these systems enable objective assessment of athlete progress, functional recovery, and performance adaptation. Although the work does not specifically focus on disease diagnosis, it highlights the growing importance of wearable technologies in supporting evidence-based rehabilitation strategies and long-term performance optimization. This study contributes to the understanding of how wearable sensor platforms can bridge the gap between athletic performance monitoring and post-injury rehabilitation, which remains a critical challenge in sports technology applications.

Anastasiou et al. (2022) present a systematic design and evaluation methodology for wearable devices aimed at performance measurement and athlete injury prevention. Their work emphasizes a user-centered development process, incorporating ergonomic design, sensor placement optimization, and performance validation to ensure reliable data acquisition during sports activities. The proposed methodology enables the assessment of both physical performance metrics and injury-related risk factors, supporting preventative strategies in athletic training. While the study primarily focuses on performance enhancement rather than clinical diagnosis, it provides valuable insights into the design challenges of wearable sports technologies, including usability, accuracy, and real-world applicability. This research underscores the importance of robust design and validation frameworks as a future direction for developing scalable and athlete-friendly wearable biosensor systems.

It is possible to determine an athlete’s progress in this area relative to their training by measuring how well they perform. The total amount of work they do in the gym each day reflects both their overall metabolic expenditure and their individual effort levels in the gym.

Table 3 summarizes the integration of various wearable sensor types with artificial intelligence (AI) models for monitoring physiological, biomechanical, and biochemical parameters in sports applications. The table highlights sensor placement, data characteristics, AI-based processing approaches, monitoring objectives, and data acquisition frequency, demonstrating the growing role of intelligent data analytics in wearable sports technologies.

Biopotential sensors such as electroencephalography (EEG), electrocardiography (EKG), and electromyography (EMG) are widely employed for real-time monitoring of neural activity, cardiac function, and muscle performance. EEG sensors positioned on the head or behind the ear acquire raw brain signals across a wide frequency range, which are processed using deep learning models including long short-term memory (LSTM), gated recurrent unit (GRU), and convolutional neural networks (CNN) to detect mental fatigue, focus levels, and stress states. Similarly, EKG sensors placed on the chest or wrist capture high-frequency cardiac signals that are analyzed using LSTM- and CNN-based architectures to enable arrhythmia detection, heart rate monitoring, and early warning of cardiac stress. EMG sensors applied to the arms and legs provide muscle activation signals, allowing AI models to assess muscle fatigue levels and detect sudden spasms during physical activity.

Optical and electrodermal sensors, including photoplethysmography (PPG) and galvanic skin response (GSR), further extend physiological monitoring capabilities. Wrist-mounted PPG sensors continuously measure heart rate, blood pressure, and blood oxygen saturation (SpO2), with recurrent and convolutional neural networks commonly used for signal interpretation. GSR sensors placed on the wrist, hand, or leg provide periodic data related to skin conductance, enabling AI-driven estimation of stress levels and dehydration status.

Environmental and biochemical sensing modalities are also increasingly integrated into wearable platforms. Temperature and humidity sensors positioned on the body allow periodic monitoring of thermal regulation and hydration status, typically processed using artificial neural networks (ANN). Glucose sensors operating through subcutaneous insertion or sweat analysis provide periodic measurements of blood glucose levels, with AI models such as ANN, CNN, recurrent neural networks (RNN), and gradient boosting methods supporting the detection of hypoglycemic and hyperglycemic events.

Finally, inertial sensors measuring pressure, acceleration, and angular velocity are commonly deployed on the ankle, knee, waist, or chest to capture motion-related data. These signals, analyzed using CNN, LSTM, and k-nearest neighbor (KNN) models, enable instantaneous detection of balance loss, falls, shocks, and abnormal movement patterns, which are critical for injury prevention in sports.

Overall, the table illustrates how the convergence of wearable sensing technologies and artificial intelligence enables continuous or periodic data-driven assessment of athlete health, performance, and injury risk. Despite their potential, challenges remain regarding data reliability, model generalization, sensor fusion, and real-time implementation, highlighting important directions for future research in intelligent wearable sports systems.

4.2 AI-driven signal processing, sensor fusion, and predictive analytics

AI-driven multimodal sensing is increasingly enabling the integration of heterogeneous physiological and behavioural signals for real-time and personalized sports monitoring. Xi et al. developed a multimodal wearable framework that synchronized physiological and behavioural signals and integrated a Transformer–GCN architecture for real-time action recognition and personalized exercise prescription. The framework demonstrated a 20.1% improvement in VO2max and a 99.3% increase in muscular endurance after a 12-week intervention, highlighting the potential of AI-driven multimodal sensor fusion for personalized sports monitoring (Xi et al., 2026).

Beyond conventional multimodal fusion approaches, recent studies have increasingly incorporated attention-based deep learning to account for the temporal and spatial heterogeneity of wearable signals. Lv et al. developed a spatial–temporal attention-enhanced LSTM framework that integrated HR/HRV, three-axis acceleration and environmental data to optimize personalized exercise volume in university basketball. The model achieved 85.3% accuracy in exercise-intensity classification, outperforming conventional approaches by 13.2%, while multimodal fusion reduced assessment errors by 15.2%. The personalized correction mechanism further improved recognition performance in novice participants by 18.5%, highlighting the potential of AI-driven multimodal sensing for individualized sports monitoring (Lv et al., 2025).

Beyond data fusion, AI-based approaches can further improve artifact robustness in wearable physiological monitoring. Lim et al. developed a CNN-based autoencoder (CNNAED) framework for R-peak detection in motion- and EMG-contaminated wearable ECG recordings. Across 11,598 validated segments, the approach reduced heart-rate estimation error from 13.26 to 9.37 beats min-1, corresponding to a 29.3% improvement (p < 0.001), while RMSSD improved by 6.1% (p < 0.001). These findings demonstrate the potential of deep learning for artifact suppression while preserving clinically relevant cardiac timing information (Lim et al., 2026).

AI-based analysis also extends to real-time recognition of sport-specific activities. Cuperman et al. used wearable accelerometer data with a CNN–bidirectional LSTM architecture to classify five football-related activities, including running, sprinting, passing, shooting and jumping. The model achieved up to 98.3% accuracy and operated 2.7–3.4 times faster than conventional machine-learning approaches, demonstrating the potential of deep learning for accurate and computationally efficient wearable activity recognition (Cuperman et al., 2022).

At the system level, recent reviews have further highlighted the integration of smart textile sensors with machine learning for continuous athlete monitoring. Sun et al. reported that ML-enabled e-textile systems can support movement classification, fatigue detection and cardiovascular and metabolic state monitoring through the integration of biomechanical, biopotential and biochemical signals. However, data scarcity, model generalizability, motion-induced signal noise, durability and edge-computing constraints remain important barriers to real-world deployment (Sun and Yin, 2025).

Beyond model development, the practical deployment of AI in wearable sports systems increasingly depends on edge intelligence and Tiny Machine Learning (TinyML). Rather than transmitting all raw physiological and biomechanical data to cloud servers, lightweight models can perform signal-quality assessment, artifact detection, feature extraction, and selected activity or fatigue inference directly on wearable or smartphone hardware. Model quantization, pruning, and knowledge distillation can reduce memory and computational requirements, although these approaches introduce trade-offs between predictive accuracy, inference latency, and energy consumption (Parvin et al., 2025; Heydari and Mahmoud, 2025). A hierarchical edge–cloud architecture may therefore be more appropriate for multimodal sports monitoring, in which high-frequency ECG, EMG, and inertial signals are processed locally, while computationally intensive multimodal modelling and longitudinal athlete profiling are performed at edge or cloud infrastructure. Federated learning could further support personalized model development without requiring continuous transfer of raw physiological data; however, communication overhead, device heterogeneity, data non-independence, and privacy risks remain important limitations (Kei et al., 2025; Oloko-Oba et al., 2026).

Beyond monitoring, AI can support personalized and adaptive training decisions. Xia et al. developed a deep reinforcement learning framework that integrated real-time physiological monitoring with individual athlete characteristics to optimize training load. Across multiple sports, the system improved performance by 12.3% (95% CI, 10.1%–14.5%; p < 0.001) and reduced injury rates by 43%, while maintaining a response time below 2 s. These findings highlight the potential of AI-driven wearable systems to move from passive monitoring towards individualized training optimization, although cold-start requirements, implementation costs and limited population diversity remain important translational barriers (Xia et al., 2026).

An additional opportunity for AI lies in adaptive sensor calibration. Wearable biochemical and electrophysiological signals are highly susceptible to temperature variation, sweat composition, electrode–skin impedance, mechanical displacement, biofouling, and progressive sensor ageing, making fixed calibration increasingly inadequate for prolonged athletic monitoring (Abbas et al.). AI-based regression, adaptive filtering, transfer learning, and domain-adaptation strategies could continuously update sensor-specific calibration using contextual variables such as skin temperature, sweat rate, signal quality, and previous measurements. However, adaptive calibration introduces an important trade-off: excessive adaptation may incorrectly interpret genuine physiological changes as sensor drift, whereas insufficient adaptation may fail to compensate for sensor degradation. Future systems should therefore combine adaptive calibration with signal-quality assessment and uncertainty estimation to distinguish physiological changes from sensor-induced deviations.

Similarly, multimodal AI approaches have also been investigated for sports injury prediction and rehabilitation, integrating sensor fusion, time-series classification and predictive analytics to support early risk detection and individualized recovery. Wearable and vision-based systems can enable real-time motion assessment and adaptive feedback, although model generalization, interpretability, privacy and clinical validation remain important translational challenges (Wang et al., 2026). The combination of edge AI and multimodal sensing could ultimately enable closed-loop wearable systems in which physiological state estimation is directly translated into individualized feedback. For example, simultaneous detection of elevated cardiovascular strain, neuromuscular fatigue, and metabolic stress could trigger adaptive recommendations regarding exercise intensity or recovery. Such systems require not only high predictive accuracy but also uncertainty-aware decision-making and reliable detection of missing or corrupted sensor inputs. At the communication level, emerging 6G architectures may further facilitate distributed edge–cloud analytics and low-latency exchange among wearable devices and computational nodes (Nemane et al., 2026). Nevertheless, communication latency alone does not determine physiological responsiveness, particularly for biochemical sensors whose response is constrained by sweat transport and biomarker kinetics. Thus, 6G should be considered an enabling infrastructure rather than a substitute for efficient sensing, processing, and multimodal fusion.

Collectively, these studies demonstrate that AI can transform wearable sports technologies from isolated sensing platforms into integrated and personalized monitoring systems. However, data availability, model generalizability, computational demands and real-world validation remain key barriers to clinical and athletic translation.

4.3 System-level hardware integration and Co-location bottlenecks

The integration of heterogeneous sensors into a single wearable platform requires coordinated solutions for data synchronization, sensor fusion, power management, wireless communication, computational efficiency and user comfort. These system-level considerations are particularly important in sports environments, where dynamic movements, continuous monitoring and variable operating conditions place simultaneous demands on sensing, processing and communication components.

Wang et al. developed a multilayer data-fusion framework that integrated IMU, GPS, physiological and positioning data through adaptive weighting and asynchronous alignment algorithms in team sports. Across controlled basketball and football experiments involving 40 semi-professional athletes, the approach improved signal quality by 8.6 dB and positioning accuracy by 42.3% compared with single-source approaches, while maintaining real-time response times of 192–312 m and accuracies of 84.2%–91.4%. These findings highlight the importance of temporal synchronization and adaptive fusion when integrating heterogeneous wearable sensors in dynamic sports environments (Wang et al., 2025).

Beyond synchronization, effective integration also depends on the ability to combine heterogeneous signals at the algorithmic level. Gai et al. developed a multimodal wearable system integrating flexible sensors, artificial synapses and machine learning for real-time athlete health monitoring and injury prevention. The framework employed feature-level sensor fusion combined with SVM and LSTM networks, achieving 92.1% accuracy for abnormal movement and injury-risk prediction, with an R2 of 0.96 and an RMSE of 5.41 for health monitoring. These results highlight the potential of feature-level fusion to integrate heterogeneous wearable signals for real-time and personalized sports monitoring (Gai, 2025).

At the hardware level, continuous multimodal sensing also increases energy and hardware demands. Nafaji et al. developed the VersaSens platform, a modular wearable sensing system designed to support diverse edge-AI applications while maintaining low energy consumption. The platform integrates modular sensor, processor and co-processor components, and the incorporation of a hardware-accelerated edge-AI co-processor further improved overall runtime and energy efficiency. These findings highlight the importance of modular hardware and energy-efficient edge processing for sustaining continuous multimodal wearable monitoring (Najafi et al., 2024).

Wireless connectivity is similarly essential for real-time data exchange between sensing and processing units. Qi et al. developed a wireless multimodal respiratory and activity monitoring (WRAM) system integrating chest-band sensors, a mobile device and a data-processing centre for real-time monitoring. The system employed multimodal fusion architecture to simultaneously characterize respiratory patterns and physical activities, achieving 97.22% mean activity-recognition accuracy with a prediction time of 0.0094 s across 15 activities. The wireless architecture enabled continuous interaction between wearable sensors and processing units, demonstrating the feasibility of real-time multimodal monitoring during daily activities (Qi and Aliverti, 2020).

As multimodal systems incorporate increasingly diverse data streams, computational efficiency also becomes a critical consideration. Wilk et al. developed a computationally efficient multimodal wearable system combining camera-based and inertial sensing for three-dimensional motion tracking during strength training. By integrating visual reference points with inertial orientation data, the system enabled real-time 3D pose estimation while reducing the computational burden associated with multimodal processing. Experimental validation during weightlifting squat movements yielded RMSE values of 36.7 mm and 13.6 mm under static and mobile conditions, respectively, demonstrating the feasibility of computationally efficient sensor fusion for sports motion monitoring (Wilk et al., 2021).

Beyond technical performance, successful co-location of multiple sensing components must also preserve user comfort and ergonomic compatibility. Yang et al. developed a body-shape-aware multimodal framework for predicting and optimizing comfort in smart sportswear under dynamic movements and individual body-shape variations. By integrating visual reconstruction, pressure-array and posture data through spatiotemporal graph attention, the framework modelled the dynamic interaction between body topology and garment pressure distribution. The integration of individual body measurements further enabled optimization of garment parameters, including fabric thickness, seam tension and elasticity distribution. The proposed approach achieved a mean absolute error of 1.32 and an R2 of 0.916 for comfort-score prediction, while improving personalized comfort by 21.4%, demonstrating the potential of multimodal sensing for ergonomic and individualized sportswear design (Yang et al., 2026).

Although wearable technologies are widely used for sports and health monitoring, the validity and reliability of the metrics they measure can be limited, especially in real-world and high-intensity conditions. The rapid development of these technologies can lead users to overestimate the accuracy of the measurements. Therefore, it is important to transparently verify sensor performance under different activity conditions and evaluate it according to individual user characteristics. The findings show that wearable devices can provide more reliable results in controlled or low-intensity activities, but performance degradation may be observed in real-world field conditions (Shei et al., 2022).

Beyond sensor accuracy, system-level interoperability, standardization and data privacy remain important challenges. You et al. proposed a 6G-enabled edge computing architecture addressing standardization, interoperability, data privacy and secure communication in wearable healthcare and sports systems. The five-layer framework integrates device onboarding, data semantics, secure transport, QoS, edge–cloud collaboration and privacy controls to facilitate interoperability among heterogeneous wearable platforms. Performance metrics including latency, jitter, data loss and mobility continuity were incorporated for system-level validation, while privacy-preserving approaches such as federated learning supported scalable and secure multi-provider wearable networks (You et al., 2026).

Beyond short-term validation, long-term monitoring is essential for determining whether wearable-derived metrics remain reliable across changing training and recovery conditions. Spetz et al. monitored 20 national-level endurance athletes for 1 year using multiple wearable devices, including GPS watches, heart-rate monitors, Oura rings and continuous glucose monitors, together with subjective assessments and POMS scores. Significant associations were observed between wearable-derived measures and perceived recovery and wellbeing, although time-series analyses revealed substantial individual variability. The findings highlight the value of integrating objective and subjective data and emphasize the need for individualized, long-term monitoring to improve assessment of training load, recovery and athletic performance under real-world conditions (Spetz et al., 2025).

Such long-term monitoring is complemented by validation under demanding, high-intensity sporting conditions, where motion, physiological stress and environmental factors can challenge sensor performance. Ousaka et al. evaluated the feasibility of continuous ECG monitoring during a full marathon using a textile-integrated wearable ECG sensor in 20 healthy participants. Adequate data collection was achieved in 65% of runners, while lower data quality was observed among female participants and during the early race stages. These findings demonstrate the feasibility of wearable ECG monitoring under real-world marathon conditions while highlighting challenges related to data loss, device ergonomics and software performance (Ousaka et al., 2022).

Importantly, real-world validation should also account for user-specific characteristics that may influence sensing accuracy. Hung et al. evaluated the accuracy of a wrist-worn Fitbit Charge five compared with a Polar H10 chest strap across different skin tones and exercise intensities. Among 25 participants, heart-rate measurement errors increased with exercise intensity, particularly in participants with darker skin tones. These findings highlight the importance of considering skin tone and exercise intensity when validating optical wearable sensors for reliable physiological monitoring (Hung et al., 2025).

Collectively, these studies demonstrate that reliable multimodal wearable systems require a balance between sensing accuracy, energy efficiency, computational performance, user comfort and system-level interoperability. Real-world and long-term validation further highlights the effects of exercise intensity, individual variability and data quality on wearable performance. These challenges emphasize the need for standardized validation and robust testing across diverse users and demanding athletic conditions.

4.4 Technical bottlenecks and current limitations

The transition of multimodal wearable biosensors from controlled laboratory experiments to real-world athletic environments remains constrained by interconnected limitations in signal quality, sensor stability, calibration, energy consumption, data security, and environmental robustness. Importantly, these challenges should not be considered independently. Increasing sensor density, for example, can improve physiological coverage while simultaneously increasing power consumption, computational requirements, and susceptibility to cross-modal interference. Similarly, enhanced encapsulation may improve environmental protection but can compromise flexibility, breathability, and long-term skin compatibility. Recent reviews of wearable sensing technologies have consequently emphasized that sensor performance under controlled conditions does not necessarily translate into reliable longitudinal operation during unrestricted physical activity (Jin et al., 2026).

Rapid and repetitive athletic movements can introduce substantial motion artifacts (MAs) into biopotential, optical, and mechanical sensing modalities. In ECG and sEMG measurements, relative displacement between the electrode and skin alters the electrode–skin interface and impedance, generating baseline fluctuations and motion-induced noise that may overlap with physiologically relevant signal components. Such effects can become particularly pronounced during running, jumping, throwing, and contact sports, where acceleration, skin deformation, and electrode displacement occur simultaneously (Sirtoli et al., 2023). PPG measurements are similarly vulnerable because changes in sensor–skin contact pressure, tissue deformation, and local blood-volume distribution can modify the optical path and introduce transient signal distortion. Importantly, conventional filtering cannot always eliminate these artifacts without also distorting physiologically meaningful signal components. Recent approaches have therefore shifted toward source-level suppression through skin-anchoring structures, deformation-constrained electrodes, mechanically compliant interfaces, and adaptive signal-processing methods (Wang et al., 2021). Nevertheless, motion-artifact mitigation remains a trade-off between artifact suppression, signal preservation, computational complexity, and user comfort. Consequently, multimodal sports biosensors should increasingly be validated under sport-specific dynamic conditions rather than relying predominantly on stationary or low-motion laboratory protocols.

Long-term operation introduces chemical, electrical, and mechanical degradation mechanisms that are often insufficiently captured by short-duration proof-of-concept studies. Sweat-based enzymatic biosensors, including glucose and lactate sensors, may experience biofouling, changes in electrode activity, and alterations in analyte transport resulting from the accumulation of proteins, lipids, cellular debris, and other constituents at the sensing interface. In parallel, repeated stretching, compression, bending, and shear loading during athletic activity can progressively damage conductive traces and interfaces, leading to microcracking, delamination, and changes in electrical resistance. Long-term ECG monitoring with textile electrodes similarly remains sensitive to electrode placement, skin humidity, contact pressure, and user activity (Acar et al., 2019; Nigusse et al., 2021). Recent sports-focused reviews have identified long-term operational stability, sensor calibration, motion artifacts, and inter-individual variability as major barriers to the translation of sweat-based biosensors from laboratory prototypes to field-deployable systems.

Importantly, mechanical flexibility alone does not guarantee long-term durability. Highly compliant materials can improve conformal contact but may undergo fatigue under repeated deformation, whereas stronger encapsulation can improve environmental protection at the expense of flexibility and breathability. Therefore, durability assessment should incorporate repeated mechanical cycling, prolonged on-body operation, sweat exposure, washing or cleaning cycles where relevant, and monitoring of sensor sensitivity and baseline drift over time. Such longitudinal characterization is necessary to distinguish initial sensor performance from genuine operational stability.

Calibration drift represents another major barrier to reliable longitudinal monitoring. Electrochemical, optical, and electrophysiological measurements can be affected by temperature, sweat rate, pH, ionic composition, skin hydration, electrode–skin impedance, and sensor ageing. In sweat-based sensing, changes in sweat secretion and evaporation may alter local analyte concentration and transport independently of systemic physiological changes. Consequently, a calibration established under resting or controlled conditions may not remain valid during prolonged exercise. Recent wearable-biosensor literature has therefore emphasized the importance of calibration strategies that account for sweat rate, temperature, exercise intensity, and inter-individual variability (Mondal and Saikia, 2026).

Several strategies have been proposed, including temperature compensation, microfluidic control of sample transport, reference electrodes, signal-quality monitoring, and adaptive calibration algorithms. However, adaptive calibration introduces an important trade-off: excessive adaptation may incorrectly interpret genuine physiological changes as sensor drift, whereas insufficient adaptation may fail to compensate for progressive sensor degradation. Thus, future multimodal systems should combine individualized calibration with contextual variables and uncertainty estimation rather than relying exclusively on a single pre-use calibration step.

Power consumption becomes increasingly important as ECG, EMG, inertial, optical, and electrochemical sensors are integrated with analog front-end circuits, high-frequency data acquisition, onboard processing, and wireless communication. Continuous acquisition of multiple high-bandwidth signals can substantially increase energy demand, while transmission of raw data may impose an additional communication burden. At the same time, sports wearables must remain lightweight, thin, and mechanically unobtrusive, limiting the physical volume available for energy storage. Energy limitations therefore create a fundamental trade-off among sensing frequency, computational complexity, communication rate, battery capacity, and device weight (Rong et al., 2021).

Power-efficient architectures can partially address this limitation through duty cycling, adaptive sampling, power gating, local feature extraction, and edge-based inference. Rather than continuously transmitting raw multimodal data, wearable devices can perform preliminary signal-quality assessment and feature extraction locally and transmit only relevant information. However, aggressive duty cycling or downsampling may reduce temporal resolution and potentially obscure short-duration physiological events. Therefore, future systems should report not only sensing and classification accuracy but also energy consumption per inference, continuous operating time, and performance under simultaneous multimodal acquisition.

Wearable sports systems continuously generate longitudinal physiological, biochemical, biomechanical, and behavioural information. These datasets may have considerable personal, medical, and commercial value, particularly in elite sports, where physiological profiles and performance trajectories may influence team selection, contracts, sponsorships, and competitive strategy. Importantly, privacy risks are not eliminated simply by removing direct identifiers. A systematic review of wearable-device data demonstrated that physiological signals can support re-identification, with many studies reporting high identification performance from apparently non-identifying wearable signals (Chikwetu et al., 2023).

Additional vulnerabilities may arise during wireless transmission, smartphone synchronization, cloud storage, and AI model training. Consequently, secure authentication, encrypted communication, access control, hardware-assisted cryptography, data minimization, and privacy-preserving computation should be incorporated into the system architecture rather than added after deployment. Federated learning represents one promising approach because it allows models to be trained across decentralized datasets without directly transferring raw physiological data; however, it does not completely eliminate privacy and security risks, including model inversion, gradient leakage, data heterogeneity, and communication overhead (Ali et al., 2023).

Perhaps the most important translational limitation is the performance gap between controlled laboratory validation and unrestricted athletic environments. Many wearable systems are evaluated using treadmill running, stationary cycling, controlled exercise protocols, or relatively short-duration experiments. In contrast, outdoor and competitive sports expose sensors to variable temperature, humidity, solar radiation, sweat accumulation, rain, repeated impacts, abrupt movements, changing body orientations, and inconsistent sensor placement. These factors can simultaneously affect adhesion, mechanical integrity, optical measurements, electrochemical response, electrode–skin contact, and wireless communication.

Environmental and physiological variability also creates a substantial distribution shift between training datasets and real-world deployment conditions. An algorithm trained using a small number of athletes under standardized laboratory conditions may perform substantially differently when applied to athletes with different body compositions, training statuses, movement patterns, hydration levels, or sensor-placement configurations. Recent reviews have therefore identified environmental robustness, long-term wearability, multimodal integration, calibration, and field validation as persistent barriers to practical deployment (Jin et al., 2026).

Consequently, high sensitivity, low detection limits, or high classification accuracy obtained under controlled conditions should not be interpreted as direct evidence of field readiness. Robust translational evaluation should incorporate prolonged on-body testing, multiple athletes, different exercise intensities, realistic environmental conditions, repeated-use cycles, sensor-placement variability, and comparison with appropriate reference measurements. In particular, sports-specific validation should include the actual movement patterns and environmental conditions encountered during training and competition rather than relying solely on generic laboratory exercise protocols.

Collectively, these limitations demonstrate that the principal bottleneck in multimodal wearable sports biosensing is no longer the development of individual high-performance sensors, but the simultaneous preservation of analytical accuracy, mechanical integrity, energy efficiency, calibration stability, cybersecurity, and user acceptability during prolonged real-world operation. Improvements in one dimension may introduce compromises in another: increasing sensor density can improve physiological coverage while increasing power and computational demands; stronger encapsulation can enhance environmental protection while reducing flexibility and breathability; and more sophisticated AI models can improve predictive performance while increasing memory, energy, and interpretability requirements. Therefore, future research should move beyond isolated sensitivity, detection-limit, or classification-accuracy metrics toward standardized, longitudinal, system-level benchmarking that simultaneously evaluates signal drift, motion robustness, mechanical durability, energy consumption, calibration stability, privacy, and multimodal reliability under realistic sporting conditions. This shift from sensor-level optimization to system-level validation will be essential for translating multimodal wearable biosensors from laboratory prototypes into dependable tools for continuous athlete monitoring (Mondal and Saikia, 2026).

5 Conclusion

This article provides a comprehensive analysis and evaluation into the categories, positioning, data collection methodologies, and prevailing applications of sensor structures employed within the domain of wearable technology and sports-related devices. The advent of wearable sensors has enabled the monitoring of athletes’ health by a diverse range of stakeholders, including users, athletes, coaches, trainers, club owners, and numerous others. This monitoring encompasses not only the tracking of physical activities but also the collection of data from multiple sensor structures. The resultant outcomes of this process include enhanced athlete training, modifications to training methods, and improved health. Despite the extensive research that has been conducted on the subject of wearable technologies, this article aims to address a significant gap in the existing literature by improving quality and thoroughly examining the latest developments in wearable devices and technologies. The present study provides an overview of the current landscape of wearable technologies, examining sensor types and placement strategies. There are ongoing opportunities to enhance quality and address current challenges.

Performance Evaluation: The evaluation of athletes’ performance is facilitated by the utilisation of sensors and images. The objective of the programme is twofold: firstly, to identify the potential strength of athletes; and secondly, to analyse their training and on-field performance.

Training Scores: This approach is instrumental in ensuring the identification of suitable training programmes for athletes during both training and preparation phases. The objective of this initiative is to mitigate the risk of injury for athletes.

The Athlete Injury Prevention and Rehabilitation Process: The integration of wearable devices and technologies has been identified as a factor in the development of effective injury prevention strategies and the collection of athlete data. The system has been developed as a preventative measure against a range of health issues, including dehydration, muscle fatigue, muscle tears, heart problems and overexertion. For athletes who have suffered such injuries, it is imperative that they resume their sports careers expeditiously and in a manner that prevents the recurrence of the injury.

The utilisation of wearable technologies incorporating artificial intelligence (AI), virtual reality (VR), and augmented reality (AR) is expected to play a substantial role in promoting athlete health and facilitating injury recovery. However, the adaptation of training programmes to these emerging systems remains an area that warrants further investigation.

In sports science, the implementation of AI facilitates the prediction of musculoskeletal injuries, the evaluation of neurological activity, and the continuous monitoring of metabolic stress through sensor-derived data. Strategic optimization of the AI-sensor synergy is essential for maximizing outcomes in athlete health. These analytics are increasingly accessible via cross-platform interfaces on mobile and desktop devices, with the primary objective being the development of early-warning systems and performance optimization frameworks.

This review provides a comprehensive analysis of recent advancements in wearable technologies, elucidating their functional capabilities and research trends. While the sustained utilization of Inertial Measurement Unit (IMU) systems is emphasized due to their cost-effectiveness and accessibility, there is an imperative need to integrate biosensors and chemical-based sensors into wearable architectures. Such integration would facilitate a more holistic analysis of athletic performance. Notably, the current literature reveals a significant paucity of studies regarding chemical-based sensing in sports, which represents a critical gap in the field. The exponential growth in wearable research over the past 5 years suggests that this sector will continue to evolve, attracting intensified academic and industrial interest.

Finally, the marked increase in research on wearable devices over the past 5 years, coupled with the proliferation of consumer-oriented products in the sector, indicates that this field is likely to continue expanding and attracting growing research attention. The miniaturisation of sensors, coupled with their enhanced accuracy, is poised to catalyse the proliferation of wearable technologies.

Statements

Author contributions

BA: Conceptualization, Data curation, Investigation, Methodology, Resources, Visualization, Writing – original draft, Writing – review and editing. MG: Conceptualization, Data curation, Resources, Validation, Writing – original draft, Writing – review and editing. BS: Conceptualization, Methodology, Resources, Software, Validation, Visualization, Writing – original draft, Writing – review and editing. SY: Conceptualization, Investigation, Validation, Visualization, Writing – original draft, Writing – review and editing. FC: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review and editing.

Funding

The author(s) declared that financial support was not received for this work and/or its publication.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The author MG declared that they were an editorial board member of Frontiers at the time of submission. This had no impact on the peer review process and the final decision.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1

    AbbasS. R.AbbasZ.ZahirA.LeeS. W. (2024). Federated Learning in Smart Healthcare: A Comprehensive Review on Privacy, Security, and Predictive Analytics with Iot Integration. 10.3390/healthcare12242587

  • 2

    Abdul-HussainG.HolderbaumW.TheodoridisT.WeiG. (2023). Modified nonlinear hysteresis approach for a tactile sensor. Sensors23, 7293. 10.3390/s23167293

  • 3

    AcarG.OzturkO.GolparvarA. J.ElboshraT. A.BöhringerK.Kaya YapiciM. (2019). Wearable and flexible textile electrodes for biopotential signal monitoring: a review. Electron8, 479. 10.3390/electronics8050479

  • 4

    Aguilar-ToránJ.Rabost-GarciaG.Toinga-VillafuerteS.Álvarez-CarullaA.Colmena-RubilV.Fajardo-GarciaA.et al (2023). Novel sweat-based wearable device for advanced monitoring of athletic physiological biometrics. Sensors23 (23), 9473. 10.3390/s23239473

  • 5

    AkininA.PaulA.WangJ.BuccinoA.CauwenberghsG. (2020). 6 Biopotential measurements and electrodes. Springer, Cham: Neural Engineering. 65–96. 10.1007/978-3-030-43395-6_2

  • 6

    Al-SheikhB. (2023). Adaptive algorithm for motion artifacts removal in wearable biomedical sensors during physical exercise. IEEE Sens. J.23, 9491–9499. 10.1109/JSEN.2023.3256959

  • 7

    AliM.NaeemF.TariqM.KaddoumG. (2023). Federated learning for privacy preservation in smart Healthcare systems: a comprehensive survey. IEEE J. Biomed. Heal. Inf.27, 778–789. 10.1109/JBHI.2022.3181823

  • 8

    AnastasiouA.NikakiA.PitoglouS.KoumpourosY. (2022). Proposed design and assessment methodology of a wearable device for prevention and performance evaluation of athletes. Int. J. Reliab. Qual. E-Healthcare11, 1–13. 10.4018/IJRQEH.297089

  • 9

    AngelucciA.TariqM.KaddoumG. (2021). Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques. 10.3390/s21030814

  • 10

    AssalveG.LunettiP.Di CagnoA.De LucaE. W.AldegheriS.ZaraV.et al (2024). Advanced wearable devices for monitoring sweat biochemical markers in athletic performance. A Compr. Rev.14, 574. 10.3390/bios14120574

  • 11

    BiY.SunM.WangJ.ZhuZ.BaiJ.EmranM. Y.et al (2023). Universal fully integrated wearable sensor arrays for the multiple electrolyte and metabolite monitoring in raw sweat, saliva, or urine. Anal. Chem.95 (16), 6690–6699. 10.1021/acs.analchem.3c00361

  • 12

    ButkeviciuteE.BikulcieneL.SidekerskieneT.BlazauskasT.MaskeliunasR.DamaseviciusR.et al (2019). Removal of movement artefact for Mobile EEG analysis in sports exercises. IEEE Access7, 7206–7217. 10.1109/ACCESS.2018.2890335

  • 13

    ChenF.WangJ.ChenL.LinH.HanD.BaoY.et al (2024). A wearable electrochemical biosensor utilizing functionalized Ti3C2Tx MXene for the real-time monitoring of uric acid metabolite. Anal. Chem.96, 3914–3924. 10.1021/acs.analchem.3c05672

  • 14

    ChenY.HeZ.WuY.BaiX.LiY.YangW.et al (2025). A wearable molecularly imprinted electrochemical sensor for cortisol stable monitoring in sweat. Biosensors15, 194. 10.3390/bios15030194

  • 15

    ChenM.WeiJ.HuQ.ZhaoJ.WangS.YaoS.et al (2026). Self-powered, conformable sweat sensing bioelectronics for multiplexed biomarker detection and sports health management. Nano Energy154, 111993. 10.1016/j.nanoen.2026.111993

  • 16

    ChiY. M.DeissS. R.CauwenberghsG. (2009). Non-contact low power EEG/ECG electrode for high density wearable biopotential sensor networks. Proceedings 1112- 2009 6th international workshop on wearable and implantable body sensor networks, 246–250. 10.1109/BSN.2009.52

  • 17

    ChikwetuL.MiaoY.WoldetensaeM. K.BellD.GoldenholzD. M.DunnJ. (2023). Does deidentification of data from wearable devices give Us a false sense of security?A Systematic Review5, e239–e247. 10.1016/S2589-7500(22)00234-5

  • 18

    ChoudhryN. A.RasheedA.AhmadS.ArnoldL.WangL. (2020). Design, development and characterization of textile stitch-based piezoresistive sensors for wearable monitoring. IEEE Sens. J.20 (18), 10485–10494. 10.1109/JSEN.2020.2994264

  • 19

    ChowdhuryS. S.HasanM. S.SharminR. (2019). “Robust heart rate estimation from PPG signals with intense motion artifacts using Cascade of adaptive filter and recurrent neural network,” in IEEE Region 10 Annual International Conference, Proceedings/TENCON. 10.1109/TENCON.2019.8929692

  • 20

    CömertA.HonkalaM.HyttinenJ. (2013). Effect of pressure and padding on motion artifact of textile electrodes. Biomed. Eng. Online12, 26. 10.1186/1475-925X-12-26

  • 21

    CupermanR.JansenK. M. B.CiszewskiM. G. (2022). An end-to-end deep learning pipeline for football activity recognition based on wearable acceleration sensors. Sensors22, 1347. 10.3390/s22041347

  • 22

    DahiyaE. S.KalraA. M.LoweA.AnandG. (2024). Wearable technology for monitoring electrocardiograms (ECGs) in adults: a scoping review. Sensors24 (4), 1318. 10.3390/s24041318

  • 23

    De FazioR.MastronardiV. M.De VittorioM.ViscontiP. (2023). Wearable sensors and smart devices to monitor rehabilitation parameters and sports performance: an overview. Sensors23 (4), 1856. 10.3390/s23041856

  • 24

    Di GiminianiR.CardinaleM.FerrariM.QuaresimaV. (2020). Validation of fabric-based thigh-wearable EMG sensors and oximetry for monitoring quadriceps activity during strength and endurance exercises. Sensors20 (17), 4664. 10.3390/s20174664

  • 25

    DjassemiO.Vila DieguezO.ReynosoM.KimB.La SalleT.AgajanianN.et al (2026). Continuous lactate monitoring for real-time fatigue assessment in baseball pitchers. Biosens. Bioelectron.304, 118611. 10.1016/j.bios.2026.118611

  • 26

    GaiX. L. (2025). Application of flexible sensor multimodal data fusion system based on artificial synapse and machine learning in athletic injury prevention and health monitoring. Discov. Artif. Intell.5, 31. 10.1007/s44163-025-00254-4

  • 27

    GoodsP. S. R.MaloneyP.MillerJ.JenningsD.Fahey-GilmourJ.PeelingP.et al (2023). Concurrent validity of the CORE wearable sensor with BodyCap temperature pill to assess core body temperature during an elite women’s field hockey heat training camp. Eur. J. Sport Sci.23 (8), 1509–1517. 10.1080/17461391.2023.2193953

  • 28

    GorostiagaE. M.Navarro-AmézquetaI.González-IzalM.MalandaA.GranadosC.IbáñezJ.et al (2012). Blood lactate and sEMG at different knee angles during fatiguing leg press exercise. Eur. J. Appl. Physiol.112, 1349–1358. 10.1007/s00421-011-2090-1

  • 29

    GuoW.TanC.ShiK.LiJ.WangX. X.SunB.et al (2018). Wireless piezoelectric devices based on electrospun PVDF/BaTiO3 NW nanocomposite fibers for human motion monitoring. Nanoscale10 (37), 17751–17760. 10.1039/C8NR05292A

  • 30

    HashimotoY.NotoK.TadaS.NishidaY. (2025). Wearable multimodal sensor probe for monitoring core body temperature, electrocardiogram, heart rate, and sweat rate. IEEE Access13, 70769–70778. 10.1109/ACCESS.2025.3561288

  • 31

    HeC.KorposhS.HernandezF. U.LiuL.CorreiaR.Hayes-GillB. R.et al (2020). Real-time humidity measurement during sports activity using optical fibre sensing. Sensors20 (7), 1904. 10.3390/s20071904

  • 32

    HeydariS.MahmoudQ. H. (2020). Tiny machine learning and On-Device inference: a survey of applications, challenges, and future directions. 25, 3191. 10.3390/s25103191

  • 33

    HirataA.MiyazawaT.UematsuR.KoderaS.HashimotoY.TakagaharaK.et al (2021). Body core temperature estimation using new compartment model with vital data from wearable devices. IEEE Access9, 124452–124462. 10.1109/ACCESS.2021.3110252

  • 34

    HoritaT.IshikoT. (1987). Relationships between muscle lactate accumulation and surface EMG activities during isokinetic contractions in man. Eur. J. Appl. Physiol. Occup. Physiol.56, 18–23. 10.1007/BF00696370

  • 35

    HungS. H.SerwaK.RosenthalG.EngJ. J. (2025). Validity of heart rate measurements in wrist-based monitors across skin tones during exercise. PLoS One20, e0318724. 10.1371/journal.pone.0318724

  • 36

    HuntA. P.BullerM. J.MaleyM. J.CostelloJ. T.StewartI. B. (2019). Validity of a noninvasive estimation of deep body temperature when wearing personal protective equipment during exercise and recovery. Mil. Med. Res.6 (1), 20. 10.1186/s40779-019-0208-7

  • 37

    HwangB. U.ZabeebA.TrungT. Q.WenL.LeeJ. D.ChoiY. I.et al (2019). A transparent stretchable sensor for distinguishable detection of touch and pressure by capacitive and piezoresistive signal transduction. NPG Asia Mat.11, 23. 10.1038/s41427-019-0126-x

  • 38

    JansenR.AmentW.VerkerkeG. J.HofA. L. (1997). Median power frequency of the surface electromyogram and blood lactate concentration in incremental cycle ergometry. Eur. J. Appl. Physiol. Occup. Physiol.75, 102–108. 10.1007/s004210050133

  • 39

    JinH.WangW.ChenS.ZhangG.TongY.LuD.et al (2026). Flexible wearable sensors for sports training: recent advances and future perspectives. Mat. Des.265, 115994. 10.1016/j.matdes.2026.115994

  • 40

    JuF.WangY.YinB.ZhaoM.ZhangY.GongY.et al (2023). Microfluidic wearable devices for sports applications. Micromachines14 (9), 1792. 10.3390/mi14091792

  • 41

    KaiqiangW.XingyangL. (2020). Wearable pressure sensor for athletes’ full-range motion signal monitoring. Mat. Res. Express7, 105003. 10.1088/2053-1591/abbbcc

  • 42

    KeivanimehrA. R.AkbariM. (2025). TinyML and edge intelligence applications in cardiovascular disease. A Survey186, 109653. 10.1016/j.compbiomed.2025.109653

  • 43

    KimH.LeeK.JoG.KimJ.-S.LimM. T.ChaY. (2021). Tendon-inspired piezoelectric sensor for biometric application. IEEE/ASME Trans. Mechatronics26 (5), 2538–2547. 10.1109/TMECH.2020.3041877

  • 44

    KulkarniM. B.RajagopalS.Prieto-SimónB.PogueB. W. (2024). Recent advances in smart wearable sensors for continuous human health monitoring. Talanta272, 125817. 10.1016/j.talanta.2024.125817

  • 45

    KumarN.LinY.-J.HuangY.-C.LiaoY.-T.LinS.-P. (2023). Detection of lactate in human sweat via surface-modified, screen-printed carbon electrodes. Talanta265, 124888. 10.1016/j.talanta.2023.124888

  • 46

    LeuF.KoC.YouI.ChooK. K. R.HoC. L. (2018). A smartphone-based wearable sensors for monitoring real-time physiological data. Comput. Electr. Eng.65, 376–392. 10.1016/j.compeleceng.2017.06.031

  • 47

    LiY.SamadY. A.LiaoK. (2015). From cotton to wearable pressure sensor. J. Mat. Chem. A3 (5), 2181–2187. 10.1039/C4TA05810K

  • 48

    LiP.BaoY.ChenB.LiuX.YangH.LiQ.et al (2022). A bioinspired sweat-drainable janus electrophysiological electrode for scientific sports training. Adv. Mat. Technol.7 (10), 2200040. 10.1002/admt.202200040

  • 49

    LiangH.HeY.ChenM.JiangL.ZhangZ.HengX.et al (2021). Self powered stretchable mechanoluminescent optical fiber strain sensor. Adv. Intell. Syst.3 (Jun), 2100035. 10.1002/aisy.202100035

  • 50

    LiaqatS.DashtipourK.RizwanA.UsmanM.ShahS. A.ArshadK.et al (2022). Personalized wearable electrodermal sensing-based human skin hydration level detection for sports, health and wellbeing. Sci. Rep.12, 3715. 10.1038/s41598-022-07754-8

  • 51

    LimJ.HajebS.KongY.ChonK. H. (2026). Deep learning for suppressing EMG and motion artifacts in armband ECG R-peak detection. Biomed. Eng. Lett.16, 29–40. 10.1007/s13534-025-00507-2

  • 52

    LiuY.LinZ.ZhangY.ZhangX.LiZ.XiongR.et al (2025). BreathFIT: liquid metal-PDMS sticky conductors and AuNPs/MXene biosensors for synchronous EMG-Lactate monitoring in respiratory health. Chem. Eng. J.526, 171147. 10.1016/j.cej.2025.171147

  • 53

    LiuY.ZhouB.XuG.LuoW.HuX.GuanF.et al (2026). A plasmonic and intelligent sweat sensing patch for large-scale health monitoring. InfoMat8, e70085. 10.1002/inf2.70085

  • 54

    LuanY.XiongQ.MaM.HuangY.LiuJ.LuoL.et al (2025). Effects of aptamer-functionalized multivalent DNA nanostructures on small-molecule detection in wearable sweat sensors. ACS Sensors11 (1), 667–676. 10.1021/acssensors.5c03612

  • 55

    LvX.TaoY.XueY. (2025). Research on personalized exercise volume optimization in college basketball training based on LSTM neural network with multi-modal data fusion intervention. Appl. Sci.15, 8871. 10.3390/app15168871

  • 56

    LynnS. K.WatkinsC. M.WongM. A.BalfanyK.FeeneyD. F. (2018). Validity and reliability of surface electromyography measurements from a wearable athlete performance system. J. Sports Sci. Med.17 (2), 205–215.

  • 57

    ManjarresJ.NarvaezP.GasserK.PercybrooksW.PardoM. (2020). Physical workload tracking using human activity recognition with wearable devices. Sensors Switz.20 (1), 39. 10.3390/s20010039

  • 58

    McLarenJ.HelmerR. J. N.HorneS. L.BlanchonetteI. (2010). Preliminary development of a wearable device for dynamic pressure measurement in garments. Procedia Eng.2 (2), 3041–3046. 10.1016/j.proeng.2010.04.108

  • 59

    MessinaL.GiardiM. T. (2025). Recent status on lactate monitoring in sweat using biosensors: can this approach be an alternative to blood detection?Biosensors15 (1), 3. 10.3390/bios15010003

  • 60

    MondalR.SaikiaM. J. (2026). Advances in wearable biosensors for non-invasive biofluid monitoring. Biosensors16 (6), 336. 10.3390/bios16060336

  • 61

    NajafiT. A.CaleroJ. A. M.ThevenotJ.DucB.AlbiniS.AmirshahiA.et al (2024). VersaSens: an extendable multimodal platform for next-generation Edge-AI wearables. IEEE Trans. Circuits Syst. Artif. Intell.1, 83–96. 10.1109/tcasai.2024.3453809

  • 62

    NemaneS.SaradV. M.P. TulaskarD.MarodeT. P.BhangdiyaV.AgrawalL.et al (2026). Federated learning in multimodal healthcare diagnostics: privacy-preserving AI for biomedical imaging, electronic health records, wearables, and clinical decision support. Arch. Comput. Methods Eng.10.1007/s11831-026-10629-0

  • 63

    NigusseA. B.MengistieD. A.MalengierB.TseghaiG. B.Van LangenhoveL. (2021). Wearable smart textiles for long‐term electrocardiography Monitoring—A review. Sensors21, 4174. 10.3390/s21124174

  • 64

    Oloko-ObaM.EsenoghoE.ArulebaK. (2026). From biosignals to bedside: a review of real-time edge machine learning for wearable health monitoring. Bioeng. Basel, Switz.13 (5), 559. 10.3390/bioengineering13050559

  • 65

    OusakaD.HiraiK.SakanoN.MoritaM.HarunaM.HiranoK.et al (2022). Initial evaluation of a novel electrocardiography sensor-embedded fabric wear during a full marathon. Heart Vessels37, 443–450. 10.1007/s00380-021-01939-3

  • 66

    OweisK.QuteishatH.ZgoulM.HaddadA. (2018). “A study on the effect of sports on academic stress using wearable galvanic skin response,” in 2018 12th International Symposium on Medical Information and Communication Technology (ISMICT), 1–6. 10.1109/ISMICT.2018.8573736

  • 67

    ÖzkahramanE. E.EroğluZ.EfremovV.MaryyamA.AbbasiaslT.DasR.et al (2025). High-performance black Phosphorus/graphitic carbon nitride heterostructure-based wearable sensor for real-time sweat glucose monitoring. Adv. Mat. Technol.10 (17), e00106. 10.1002/admt.202500106

  • 68

    PalumboA.VizzaP.CalabreseB.IelpoN. (2021). Biopotential Signal Monitoring Systems in Rehabilitation: A Review. 10.3390/s21217172

  • 69

    ParkK.JeongH.JungY.SuhJ.-H.JeM.KimJ. (2025). Using biopotential and bio-impedance for intuitive human–robot interaction. Nat. Rev. Electr. Eng.2, 555–571. 10.1038/s44287-025-00191-5

  • 70

    ParvinN.JooS. W.JungJ. H.MandalT. K. (2025). Multimodal AI in biomedicine: pioneering the future of biomaterials. Diagnostics, Personalized Healthc.15, 895. 10.3390/nano15120895

  • 71

    PeiS.JiW.YangY.YangS.LiuT.DaiJ.et al (2025). An enzyme-free wearable sweat sensor based on a Cu metal-organic frame composite material for monitoring lactate metabolism. Sensors Actuators B Chem.433, 137512. 10.1016/j.snb.2025.137512

  • 72

    PhamS.YeapD.EscaleraG.BasuR.WuX.KenyonN. J.et al (2020). Wearable sensor system to monitor physical activity and the physiological effects of heat exposure. Sensors20 (3). 10.3390/s20030855

  • 73

    QiW.AlivertiA. (2020). A multimodal wearable system for continuous and real-time breathing pattern monitoring during daily activity. IEEE J. Biomed. Heal. Inf.24, 2199–2207. 10.1109/JBHI.2019.2963048

  • 74

    QinH.GuoD.ChenY. (2025). Detecting physical changes in athletes during training using flexible piezoresistive pressure sensors. MRS Commun.16, 219–227. 10.1557/s43579-025-00858-y

  • 75

    RongG.ZhengY.SawanM. (2021). Energy solutions for wearable sensors. A Review21, 3806. 10.3390/s21113806

  • 76

    SeçkinA. Ç.AteşB.SeçkinM. (2023). Review on wearable technology in sports: concepts, challenges and opportunities. Appl. Sci.13 (18), 10399. 10.3390/app131810399

  • 77

    SeshadriD. R.LiR. T.VoosJ. E.RowbottomJ. R.AlfesC. M.ZormanC. A.et al (2019). Wearable sensors for monitoring the physiological and biochemical profile of the athlete. Digit. Med.2 (1), 72. 10.1038/s41746-019-0150-9

  • 78

    SheiR. J.HolderI. G.OumsangA. S.ParisB. A.ParisH. L. (2022). Wearable Activity trackers–advanced Technology or Advanced Marketing?10.1007/s00421-022-04951-1

  • 79

    ShenD.WangJ.KoncarV.GoyalK.TaoX. (2024). Design, fabrication, and evaluation of 3D biopotential electrodes and intelligent garment system for sports monitoring. Sensors24 (13), 4114. 10.3390/s24134114

  • 80

    SirtoliV. G.LiaminiM.LinsL. T.Lessard-TremblayM.CowanG. E. R.ZednikR. J.et al (2023). Removal of motion artifacts in capacitive electrocardiogram acquisition: a review. IEEE Trans. Biomed. Circuits Syst.17, 394–412. 10.1109/TBCAS.2023.3270661

  • 81

    SpetzL.RogestedtJ.NilssonR.MattssonC. M.LarsenF. J. (2025). Validating subjective ratings with wearable data for a nuanced understanding of load-recovery status in elite endurance athletes. Sport. Med. - Open11, 154. 10.1186/s40798-025-00958-y

  • 82

    SunZ.YinL. (2025). Intelligent textile sensors coupled with machine learning for athlete physiological monitoring: a review of recent progress. Sens. Rev.46, 583–603. 10.1108/SR-08-2025-0563

  • 83

    SunY.YuX. B. (2016). Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review. 10.1109/JSEN.2016.2519392

  • 84

    TanW.ShiZ. Y.KopelmanR. (1992). Development of submicron chemical fiber optic sensors. Anal. Chem.64, 2985–2990. 10.1021/ac00047a019

  • 85

    TangC.ZhouK.WangR.LiM.LiuW.LiC.et al (2024). Wearable biosensors for human sweat glucose detection based on carbon Black nanoparticles. Anal. Bioanal. Chem.416 (6), 1407–1415. 10.1007/s00216-024-05135-w

  • 86

    TenanM. S.McMurrayR. G.Troy BlackburnB.McGrathM.LeppertK. (2011). The relationship between blood potassium, blood lactate, and electromyography signals related to fatigue in a progressive cycling exercise test. J. Electromyogr. Kinesiol.21, 25–32. 10.1016/j.jelekin.2010.09.002

  • 87

    ValchinovE.AntoniouA.RotasK.PallikarakisN. (2014). “Wearable ECG system for health and sports monitoring,” in 2014 4th International Conference on Wireless Mobile Communication and Healthcare - Transforming Healthcare Through Innovations in Mobile and Wireless Technologies (MOBIHEALTH), 63–66. 10.4108/Mobihealth33544.2014.7015910

  • 88

    VerdelN.PodlogarT.CiuhaU.HolmbergH.-C.DebevecT.SupejM. (2021). Reliability and validity of the CORE sensor to assess core body temperature during cycling exercise. Sensors21 (17), 5932. 10.3390/s21175932

  • 89

    VinothR.NakagawaT.MathiyarasuJ.MohanA. M. V. (2021). Fully printed wearable microfluidic devices for high-throughput sweat sampling and multiplexed electrochemical analysis. ACS Sensors6, 1174–1186. 10.1021/acssensors.0c02446

  • 90

    WangA.HuM.ZhouL.QiangX. (2018). Self-powered wearable pressure sensors with enhanced piezoelectric properties of aligned P(VDF-TrFE)/MWCNT composites for monitoring human physiological and muscle motion signs. Nanomaterials8 (12). 10.3390/nano8121021

  • 91

    WangL.LiuS.LiG.ZhuR. (2021). Interface sensors with skin piezo-thermic transduction enable motion artifact removal for wearable physiological monitoring. Biosens. Bioelectron.188, 113325. 10.1016/j.bios.2021.113325

  • 92

    WangZ. Z.XiaX.ChenQ. (2025). Multi-level data fusion enables collaborative dynamics analysis in team sports using wearable sensor networks. Sci. Rep.15, 28210. 10.1038/s41598-025-12920-9

  • 93

    WangP.WangA.WangS. (2026). Integrating Multimodal AI Technologies for Sports Injury Prediction and Rehabilitation: Systematic Review. 10.55860/w6j5wc21

  • 94

    WeP.GuoR.ZhangJ.ZhangY. T. (2008). “A new wristband wearable sensor using adaptive reduction filter to reduce motion artifact,” in 5th Int. Conference on Information Technology and Applications in Biomedicine, ITAB 2008 in Conjunction with 2nd Int. Symposium and Summer School on Biomedical and Health Engineering. 10.1109/ITAB.2008.4570636

  • 95

    WilkM. P.WalshM.O’FlynnB. (2021). Multimodal sensor fusion for low-power wearable human motion tracking systems in sports applications. IEEE Sens. J.21, 5195–5212. 10.1109/JSEN.2020.3030779

  • 96

    WuM.WangR.HuY.FanM.WangY.LiY.et al (2021). Invisible experience to real-time assessment in elite tennis athlete training: sport-Specific movement classification based on wearable MEMS sensor data. Proc. Inst. Mech. Eng. Part P J. Sport. Eng. Technol.237, 175433712110503. 10.1177/17543371211050312

  • 97

    WuZ.-Q.CaoX.-Q.HuaY.YuC.-M. (2024). A bifunctional wearable sensor based on a nanoporous membrane for simultaneous detection of sweat lactate and temperature. Anal. Chem.96 (7), 3087–3095. 10.1021/acs.analchem.3c05216

  • 98

    XiY.HuangT.YangZ. (2026). Multimodal human action recognition and personalized sports health promotion: a deep learning framework integrating wearable sensor fusion. Front. Neurorobot.20, 20–2026. 10.3389/fnbot.2026.1785114

  • 99

    XiaX.ChenQ.WangZ. (2026). Deep reinforcement learning-driven personalized training load control algorithm for competitive sports performance optimization. Sci. Rep.16, 845. 10.1038/s41598-025-30453-z

  • 100

    XuP.YanoT.YamamotoK.SuzukiH.KumagaiH. (1996). Characterization of a lactate oxidase from a strain of gram negative bacterium from soil. Appl. Biochem. Biotechnol.56 (3), 277–288. 10.1007/BF02786958

  • 101

    YangC. C.HsuY. L. (2010). A Review of Accelerometry-based Wearable Motion Detectors for Physical Activity Monitoring. 10.3390/s100807772

  • 102

    YangM.HouX.WuH.GuoY.ZhangJ.XieX.et al (2023). Arrayed piezoresistive and inertial measurement unit sensor-integrated assistant training tennis racket for multipoint hand pressure monitoring and representative action recognition. Sci. China Technol. Sci.66 (6), 1746–1756. 10.1007/s11431-022-2377-7

  • 103

    YangM.WangQ.YangB. (2026). A multimodal implicit neural field and spatio-temporal graph attention framework for body-shape-aware smart sportswear comfort prediction and personalized optimization. Appl. Artif. Intell.40 (1), 2700859. 10.1080/08839514.2026.2700859

  • 104

    YinJ.WangS.TatT.ChenJ. (2024). Motion Artefact Management for Soft Bioelectronics. 10.1038/s44222-024-00175-4

  • 105

    YouH.JiaY.WangY. (2026). Standards and interoperability profiles for 6G wearable health monitoring: a reference architecture for intelligent sports applications. IEEE Commun. Stand. Mag., 1–10. 10.1109/MCOMSTD.2026.3675652

  • 106

    YuM.JinJ.WangX.YuX.ZhanD.GaoJ. (2021). Development and design of flexible sensors used in pressure-monitoring sports pants for human knee joints. IEEE Sens. J.21 (22), 25400–25408. 10.1109/JSEN.2021.3087005

  • 107

    ZhangZ.SilvaI.WuD.ZhengJ.WuH.WangW. (2014). Adaptive motion artefact reduction in respiration and ECG signals for wearable healthcare monitoring systems. Med. Biol. Eng. Comput.52, 1019–1030. 10.1007/s11517-014-1201-7

  • 108

    ZhangK.GuoB.YangM.JiaY.ZhangK.WangL. (2024a). The assessment of sports performance by grip pressure using flexible piezoresistive pressure sensors in seven sports events. Sci. Rep.14 (1), 31750. 10.1038/s41598-024-82274-1

  • 109

    ZhangK.ZhangK.WangL. (2024b). The evaluation of sports performance in tennis based on flexible piezoresistive pressure sensing technology. IEEE Sens. J.24 (17), 28111–28118. 10.1109/JSEN.2024.3425591

  • 110

    ZhaoC.JiaC.ZhuY.ZhaoT. (2021). An effective self-powered piezoelectric sensor for monitoring basketball skills. Sensors21 (15), 5144. 10.3390/s21155144

  • 111

    ZhongG.LiuQ.WangQ.QiuH.LiH.XuT. (2024). Fully integrated microneedle biosensor array for wearable multiplexed fitness biomarkers monitoring. Biosens. Bioelectron.265, 116697. 10.1016/j.bios.2024.116697

Summary

Keywords

biopotential sensors, chemical sensors, hybrid biosensors, physical sensors, sports monitoring, wearable technologies

Citation

Adıgüzel B, Ghorbanpour M, Sarac B, Yücer S and Ciftci F (2026) Multimodal wearable biosensors in sports: integrating physical and chemical sensing for performance and health. Front. Sens. 7:1884845. doi: 10.3389/fsens.2026.1884845

Received

18 May 2026

Revised

23 August 2026

Accepted

28 August 2026

Published

14 October 2026

Volume

7 - 2026

Edited by

Mohamed O. Amin, University at Albany, United States

Reviewed by

Kenneth Harrington McKeever, The State University of New Jersey, United States

Shuolei Feng, Lincoln University College, Malaysia

Oscar Poudel, New Jersey Institute of Technology, United States

Updates

Copyright

*Correspondence: Fatih Ciftci, ,

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics