Abstract
Introduction:
Underground metro structures can obstruct groundwater flow, causing upstream water-level rise and pore-pressure redistribution. This study investigates the groundwater-blocking effect associated with Jinan Metro and evaluates measures for reducing the resulting engineering risk.
Methods:
A physical model system was developed to reproduce groundwater seepage during metro station construction and operation under different hydraulic gradients and diversion conditions. Pore-water pressure responses were monitored, and repeated tests were conducted to assess measurement repeatability. Six indicators were selected for risk assessment, with subjective and objective weights determined using the analytic hierarchy process and principal component analysis, respectively. TOPSIS and a normal cloud model were applied to 12 validation cases.
Results:
Without diversion, the maximum upstream water-level rise reached 2.10 m at a hydraulic gradient of 0.07. Diversion reduced water-level backwater by 74.07%–98.09% across the tested conditions. The 3,000 mm2 gravel channel provided the greatest reduction, while the 700 mm2 gravel channel and the seven connecting pipes of 5 mm diameter also performed effectively. The normal cloud model agreed with the reference results in 75.00% of cases, compared with 58.33% for TOPSIS.
Discussion:
The experiments clarify the mechanisms of local groundwater blocking and support the selection of diversion measures and risk-based engineering controls. The normal cloud model showed better agreement within the tested cases; however, the limited validation sample and simplified aquifer representation require further verification using site-specific monitoring and hydrogeological data.
1 Introduction
With the rapid development of the social economy and the accelerating urbanization process, the burden of urban transportation has been continuously increasing in recent years (He and Wang, 2013; Tong et al., 2021). Rail transit has become an important mode of transportation due to its advantages such as fast speed, large volume, safety, reliability, and punctuality. In the field of public transportation in major cities in China, the construction of rail transit systems has become the main development trend. The rapid and high-volume public transportation system driven by electricity and operated by wheel rail is called rail transit, which usually includes two forms: subway and light rail. The subway, with its advantages of not occupying ground space, not interfering with ground traffic, and carrying more passengers than light rail, has naturally become the focus of the development of the rail transit system. As a branch of urban rail transit, subway has the characteristics of large volume, high efficiency, intensification, low energy consumption, convenient riding, safety and comfort. The construction of subways is an important measure to effectively alleviate urban surface traffic congestion, and also an important way to achieve urban spatial optimization, adjustment, balanced and healthy development (Lo and Ramsay, 1991; Zhou et al., 2021).
During the construction and operation of subway stations, the problem of water level blockage caused by subway lines and stations is one of the issues that deserves close attention. At present, although the monitoring technology for groundwater level before and after the subway operation period is relatively complete, the layout of the groundwater flow field monitoring network is relatively complex, with a large amount of data, which is time-consuming and laborious. Therefore, combining risk assessment theory to evaluate the risk of groundwater level blockage caused by subway construction in karst formations has gradually become an important research direction (Lu et al., 2020; Ricci et al., 2007; Song et al., 2014).
Jinan is famous for its numerous springs, and the protection of springs is a top priority for Jinan's rail transit construction. The southern part of Jinan is characterized by low mountains and hills, with exposed Cambrian and Ordovician limestone and well-developed karst, which is easily replenished by atmospheric precipitation (Liu et al., 2025; Kong et al., 2026; Yu et al., 2026). The flow of groundwater from south to north is blocked by the intrusion of igneous rocks in the northern Yanshan Mountains, and at the same time, due to the east-west formation of the fracture zone of the Thousand Buddha Mountain and the Wenhua Bridge, the flow of groundwater is restricted on three sides, and the head of the groundwater is elevated. Under high pressure, spring water gushes out in low-lying areas along limestone fractures, karst channels, or igneous rock structural fractures, passing through thin layers of loose or gravel erosion layers. The urban rail project is located in the bustling urban area of Jinan, where springs are concentrated and exposed. It is a key planning area for the urban rail network and also a place with significant geological changes and complex structures.
Specifically, some of the lines planned for the construction of Jinan rail transit pass through the direct supply area of the “Baotu Spring Domain” and “Baiquan Spring Domain.” In this area, the spring water channel has the characteristics of shallow burial depth and strong permeability. The buried underground structure of urban rail transit is highly likely to occupy or even block the groundwater runoff channel, and the east-west direction of the subway line is prone to have an interception effect on the north-south flow of groundwater runoff. The construction of rail transit projects may damage the original groundwater runoff environment and cause significant changes in the original groundwater runoff field. At the same time, changes in the groundwater runoff environment will lead to rapid accumulation of groundwater, causing serious hydrological and geological problems during the construction and operation stages of subway stations. When tunnels or metro stations are constructed in environmentally sensitive areas, the disturbance is not limited to the structural excavation itself. More importantly, the underground structure may alter the original groundwater flow path and change the local hydrogeological equilibrium. In spring-sensitive areas, shallow aquifers, wetland systems and other groundwater-dependent environments, such changes may cause upstream water-level rise, downstream head reduction, pore-pressure redistribution and local variation in hydraulic gradient. These responses may further influence soil effective stress, ground deformation, spring discharge and the serviceability of adjacent underground structures. Therefore, the blocking effect induced by underground structures has become a key issue in the environmental impact assessment of tunnel and metro construction.
Existing studies have mainly investigated this problem using theoretical analysis, numerical simulation and field monitoring. These methods have improved the understanding of groundwater–structure interaction, but they still have certain limitations. Theoretical solutions usually require simplified assumptions regarding stratum homogeneity and boundary conditions. Numerical simulations are sensitive to hydrogeological parameters and model boundaries. Field monitoring can reflect real engineering responses, but the measured data are often affected by rainfall, pumping, recharge variation and adjacent construction activities (Chen et al., 2021; Zhang et al., 2024). It is therefore difficult to isolate the effects of structural length, burial depth and hydraulic gradient on water-level rise. Similarity physical model testing provides a useful way to reproduce the seepage response under controlled conditions and to clarify the formation mechanism of groundwater blocking.
2 Overview of the engineering
The Jinan area is bordered by the Taishan Bulge in the south and the Qihe- Guangrao Great Fracture Zone in the north, and it is a monoclinic tectonics tilted northward with the Paleozoic strata as the main body. The northern section of the Monoclinic is located at the junction of the Ruxi uplift and the North China depression, which is influenced by the Neohuaxia and late EW oriented tectonics, and has a wide range of magmatic activities, with more developed east- and west-trending minor folds and faults. At the southern edge of the monoclinic tectonics, the crystalline basement dominated by the Tethys gneiss is mainly exposed. The overlying Paleozoic cover was formed under the joint influence of the early EW-oriented tectonic system, the late NW-oriented tectonic system and the Neohuaxian system. Fractures are developed, but the development of folds and magma is not obvious, and the degree of inclination is low. The monoclinic tectonic faults are more developed, mainly in the NNW direction, with another group of NE direction intersecting with them.
The proposed subway line area in the research area belongs to the Luzhong Uplift area in terms of geological structure and the fracture structures related to the line are the Ganggou Fracture, Dongwu Fracture, Wenhuaqiao Fracture, Qianfoshan Fracture, and Chaomidian Fracture. The main Fractures involved in the KC02 section of the proposed Phase I project of a line of Jinan Metro are the Qianfoshan Fracture and the Cultural Bridge Fault.
Based on the observation records of karst water near the station and considering factors such as the annual variation of groundwater in the area, it is recommended that the water level elevation of the site be 68.0~75.5 m in the past 3~5 years. The proposal of anti-floating water level shall be made by collecting regional hydrological data and investigating the current water level, taking into account the topography and geomorphology of the site, the type of groundwater and the conditions of replenishment and discharge, and considering the hydraulic connection between the aquifers and surface water, as well as the interrelationships between the underground structures and the aquifers, the importance of the project, and the working conditions of the construction, and other factors. The site serves as a direct recharge area, and its aquifer has good permeability. Influenced by seasonal precipitation and leakage recharge from nearby flood discharge ditches, the groundwater level changes greatly. The water level dynamic shows a seasonal and periodic change characteristic of “descending, ascending, and descending” throughout the year. Generally, the water level gradually decreases from January to May, and the lowest water level appears from May to June. The rainy season from July to September approaches, and the water level rises, The highest water level lags behind the month with the highest precipitation by about 1 month.
3 Model experiments process
3.1 The derivation of similarity ratios
According to the disturbance effect of subway construction on fluid seepage processes within rock masses, the physical quantities such as fluid velocity, permeability coefficient, and pore water pressure at corresponding material points in the model and prototype physical fields are made to achieve similarity, thereby ensuring that the dehydration state of saturated aquifers in the similar model rock mass is analogous. The seepage of water in soil should satisfy the average momentum conservation equation and continuity equation for porous media flow list as Equations 1 and 2:
Among them, n represents the soil porosity, is the viscous stress tensor of the fluid, ρf is the density of the fluid, μf is the dynamic viscosity coefficient of the fluid, vfis the actual flow velocity of the fluid in the soil, is the average interaction force between the soil particles and the fluid within the unit volume, is the average particle diameter of the soil particles, and is the average movement velocity of the soil particles. In the equation , and represent the component velocities of the fluid in the x, y, and z directions, ρf is the density of the fluid, and Δx, Δy, and Δz are the lengths of the unit body.
As shown in Equations 3 and 4, the similar constants are defined respectively: pore water pressure, length, kinematic viscosity coefficient, fluid density, fluid velocity, time, average particle diameter, gravitational acceleration, laminar zone permeability coefficient, and turbulent zone permeability coefficient.
Substituting the above similar constants into the percolation equation and the continuity equation, the governing equations for the physical fields of the model are obtained as Equation 5:
If the velocity field and pore pressure field of the two physical fields are similar, then the model physical fields should also follow the above equation set, and the following similar indicators can be obtained (Equations 6 and 7).
Among them, is called the harmonic time criterion, which must be satisfied when two non-stationary motion systems are similar. is called the gravity similarity criterion, which needs to be satisfied in the similar system where the gravitational force plays the main role. is the pressure v similarity criterion. represents the similarity criterion for internal frictional force that needs to be satisfied in a similar system where viscous force plays a major role. And the seepage process of the fluid under the Darcy law should conform to the condition of .
In conclusion, if the model size is reduced to 1/N of the prototype, the soil deformation displacement will be 1/N of the prototype, the pore water pressure remains unchanged. The relevant similarity ratios are defined in Equation 8. Considering the typical size parameters of the subway station structure, the determined similarity scale is 200. The model size is reduced to 1/200 of the prototype, the soil deformation displacement is reduced to 1/200 of the prototype, the pore water pressure remains unchanged, and the permeability coefficient is reduced to 14.1 times that of the prototype. According to the similarity condition scale conversion, the similarity of various physical quantities is shown in Table 1.
Table 1
| Indicators | similarity ratio | Indicators | similarity ratio |
|---|---|---|---|
| Length | 200 | Elasticity modulus | 200 |
| Weight | 1 | Compressive strength | 200 |
| Stress | 200 | Tensile Strength | 200 |
| Strain | 1 | Permeability coefficient | 14.1 |
| Displacement | 200 | Time | 14.1 |
| Internal friction angle | 1 | Acceleration | 1 |
| Poisson's ratio | 1 | Speed | 14.1 |
Summary of similarity ratios of multiple physical field parameters.
3.2 Experiments process
After the physical model testing system was assembled and debugged, the model test was carried out following a controlled preparation–construction–monitoring procedure, as shown in Figure 1. Before testing, the raw materials for the similar strata were prepared according to the designed mix proportions. The aggregates and powders were stored separately to prevent moisture absorption, while binders such as Vaseline and silicone oil were kept away from high-temperature exposure to ensure stable material properties. The mix proportion of the similar material is listed in Table 2.
Table 2
| Material | 1~2 mm | Sand | Iron powder | Vaseline | Silicone oil | Calcium carbonate | White cement | Mixing water |
|---|---|---|---|---|---|---|---|---|
| Ratio | 0.2687 | 0.2687 | 0.23576 | 0.030177 | 0.007544 | 0.05658 | 0.07544 | 0.05695 |
Material ratio table.
Figure 1
Prior to model filling, the model box was cleaned and checked for sealing performance. Filter layers were installed at the inlet and outlet boundaries to prevent the loss of fine particles during seepage while maintaining smooth water flow. A preliminary test was then conducted to examine the stability of the water supply system, drainage system, sensors, and data acquisition device. During this stage, the similar materials were filled and compacted in layers to verify whether the model could maintain a stable seepage field and whether the sensors could accurately record pore-water pressure variations (Figure 1a).
For the formal test, the strata were constructed layer by layer according to the generalized geological profile of the proposed subway station site. Each layer was filled to the designed thickness and compacted uniformly to reduce the influence of local density variation. Pore-water pressure sensors were embedded at representative positions during the filling process, especially near the upstream side, downstream side, and surrounding area of the station structure, where the groundwater blocking response was expected to be significant.
After the completion of stratum preparation, groundwater seepage was introduced into the model. According to the designed hydraulic gradient, the water-level difference between the inlet and outlet boundaries was calculated, and the water level control system was adjusted until a stable seepage state was reached. The initial pore-water pressure and water-level distribution were then recorded as the reference state. Subsequently, the prefabricated subway station model, prepared according to the similarity ratio, was embedded into the corresponding position after local excavation of the model strata. Different working conditions were simulated by changing the hydraulic gradient, station length, and burial depth (Figures 1b and c).
To monitor the evolution of the seepage field within the physical model under the blocking effect of the metro structure, a multi-point sensor monitoring system was installed in the model test. The sensor layout was designed by considering the main groundwater flow direction, the hydraulic response characteristics on the upstream and downstream sides of the metro structure, and the variation in pore-water pressure near different stratigraphic interfaces. The monitoring points were mainly arranged in the central region of the model and in the key influence zones on both sides of the structure, so as to capture the upstream water-level rise, downstream head reduction, and local redistribution of the seepage field. The detailed layout of the sensor installation positions is shown in Figure 2.
Figure 2
During each test, the pore-water pressure and surface deformation responses were continuously recorded using the data acquisition system. Particular attention was paid to the changes in pore-water pressure and settlement near the station structure, as these areas directly reflect the redistribution of the seepage field and the development of the groundwater blocking effect. After the seepage field reached a new stable state under each working condition, the monitoring data were processed and compared to analyze the influence of structural and hydraulic factors on water-level rise and pore-pressure redistribution.
4 Data recording and analysis
After the initial flow field was adjusted, the geological units were excavated and the subway structural model was placed in position. As can be seen from Figure 3, the excavation process of the subway model is generally divided into four stages, the first stage is to stop water supply and excavate the subway station foundation pit. The second phase is the completion of pit excavation and in-pit drainage. The third phase is the completion of the drainage in the pit to take no diversionary measures to install the subway station models. The fourth stage is to adjust the water supply to the same hydraulic conditions as the initial state.
Figure 3
According to the curve of pore water pressure over time, it can be seen that 0~6 min is the initial state of hydraulic conditions, and 6~40 min is the first stage of stopping water supply and excavating the subway station foundation pit, at this time, with the increase in the depth of the excavation, digging below the infiltration line, the water in the model box began to slowly converge to the pit, part of the pore pressure sensor readings have a tendency to decrease. 40~50 min is the second stage, which is the period when the foundation pit excavation is completed and the drainage inside the foundation pit is completed. The continuous drainage inside the foundation pit leads to a larger water level difference inside and outside the foundation pit, causing faster flow of groundwater in the model.
It is not difficult to see from the Figure 4 that the pore pressure sensor P1 located near the inlet box has the largest reading change throughout the entire process, ranging from 0.730 to 1.185 kPa, and the water level change is 4.5 cm. This is because after stopping the water supply, the water level near the water inlet tank is the highest, and as time increases, the water loses faster and more toward the low water level area. From the data of pore pressure sensors near the subway station model, it can be seen that the variation curves of P3, P4, and P5 are basically consistent because they are all buried in the same layer near the excavation pit of the subway model. The sensor results after filling in the subway model are significantly larger than the initial state readings. From P6, P7, and P11, it can also be observed that there is a trend of increasing pore pressure after taking no diversion measures. The water level rise and other operating conditions caused by non-diversion measures taken after the excavation of the subway model will be further analyzed below.
Figure 4
Analyzing the water level elevation under different diversion measures with a hydraulic gradient of 0.07, it was found that the water level elevation was reduced by 74.07%, 90.47%, 97.14%, 92.38%, and 98.09% compared to the condition without diversion measures, using 300 mm2 gravel diversion channels, 500 mm2 gravel diversion channels, 700 mm2 gravel diversion channels, seven 5 mm diameter connecting pipelines, and 3000 mm2 gravel diversion channels (see Figures 4–8). Under the condition of a hydraulic gradient of 0.08, different water diversion measures were taken to analyze the water level elevation. It was found that the water level elevation was reduced by 79.55%, 90.15%, 96.21%, 94.70%, and 97.73% respectively when using a 300 mm2 gravel water diversion channel, a 500 mm2 gravel water diversion channel, a 700 mm2 gravel water diversion channel, seven 5 mm diameter connected pipelines, and a 3000 mm2 gravel water diversion channel compared to the condition without diversion measures. Under the condition of hydraulic gradient of 0.06, different water diversion measures were taken to analyze the water level elevation. It was found that the water level elevation was reduced by 74.07%, 88.89%, 96.30%, 92.59%, and 97.53% compared to the condition without diversion measures, using 300 mm2 gravel water diversion channel, 500 mm2 gravel water diversion channel, 700 mm2 gravel water diversion channel, seven 5 mm diameter connected pipelines, and 3000 mm2 gravel water diversion channel.
Figure 5
Figure 6
Figure 7
Figure 8
Under the condition of a hydraulic gradient of 0.05, different water diversion measures were taken to analyze the water level elevation. It was found that the water level elevation was reduced by 80.30%, 89.39%, 96.97%, 93.94%, and 96.97% respectively when using a 300 mm2 gravel water diversion channel, a 500 mm2 gravel water diversion channel, a 700 mm2 gravel water diversion channel, seven 5 mm diameter connecting pipelines, and a 3000 mm2 gravel water diversion channel compared to the condition without diversion measures.
Under different diversion measures and hydraulic gradients, the model test using a 300 mm2 gravel channel resulted in the highest water level backwater, while using a 3000 mm2 gravel channel resulted in the lowest water level backwater. The water level backwater values generated by using a 700 mm2 gravel channel and seven 5 mm diameter connected pipelines were relatively close to the minimum water level backwater. The analysis shows that the order of diversion effects under various diversion measures is: using 3000 mm2 crushed stone water channel > using 700 mm2 crushed stone water channel > using seven connected pipes with a diameter of 5 mm > using 500 mm2 crushed stone water channel (Table 3).
Table 3
| Hydraulic gradient | 300 mm2 gravel channel | 500 mm2 gravel channel | 700 mm2 gravel channel | Seven 5 mm pipes | 3,000 mm2 gravel channel |
|---|---|---|---|---|---|
| 0.08 | 79.55% | 90.15% | 96.21% | 94.70% | 97.73% |
| 0.07 | 74.07% | 90.47% | 97.14% | 92.38% | 98.09% |
| 0.06 | 74.07% | 88.89% | 96.30% | 92.59% | 97.53% |
| 0.05 | 80.30% | 89.39% | 96.97% | 93.94% | 96.97% |
Reduction ratio of water-level backwater under different diversion measures.
The pore-water pressure curves reflect the adjustment of the seepage field after the metro station structure was embedded in the aquifer. Before the structure was installed, groundwater mainly migrated along the original hydraulic gradient, and the pore-pressure distribution was relatively continuous. After the structure cut into the aquifer, the available seepage section was reduced and the local flow resistance increased. Consequently, groundwater was partly retained on the upstream side, resulting in water-head accumulation and an increase in pore pressure at the upstream monitoring points. On the downstream side, the hydraulic supply was weakened because the flow had to bypass the structure through lateral or vertical paths, leading to a decrease in pore pressure.
The temporal variation of pore pressure also shows a clear adjustment process. At the beginning, the obstruction of the seepage path caused a rapid change in pore pressure. With the gradual formation of bypass flow around the structure, the seepage field tended to reach a new equilibrium, and the variation rate of pore pressure decreased. The monitoring points close to the structure showed relatively moderate fluctuations, mainly because these points were affected by upstream head accumulation, downstream pressure reduction, and local seepage redistribution at the same time. These results indicate that the observed pore-pressure evolution is closely related to structural blocking, changes in hydraulic gradient, and adjustment of seepage paths.
The physical model test in this study was not intended to reproduce the full complexity of a karst groundwater system. In actual spring areas, groundwater flow may be controlled by karst conduits, large fractures, pipe flow, or subterranean rivers, and may deviate from Darcy flow. Therefore, the model should be regarded as a simplified representation of the local groundwater blocking effect induced by subway structures in the overlying Quaternary strata, rather than an equivalent simulation of the entire heterogeneous karst aquifer.
In this test, karst conduits and deep fracture-controlled flow were simplified as hydraulic boundary conditions, and the seepage response around the subway structure was approximated as porous-media flow. The results mainly provide mechanism-level understanding of water-level rise, downstream drawdown, and pore pressure redistribution caused by structural obstruction. For practical spring protection and anti-floating engineering in strongly karstified areas, these findings should be used together with site-specific hydrogeological investigation, field monitoring, and numerical analysis that accounts for conduit flow, fracture flow, or non-Darcy seepage.
After the seepage field reached a new stable state under each working condition, the monitoring data were processed and compared to analyze the influence of structural and hydraulic factors on water-level rise and pore-pressure redistribution. To evaluate the repeatability of the physical model experiments, three independent tests were conducted under a representative condition with a hydraulic gradient of 0.07 and a 700 mm2 gravel diversion channel. Before each repeated test, the inlet and outlet water levels were restored to the prescribed values, the pore-pressure sensors were checked and zeroed, and the seepage field was allowed to recover to the same initial steady state. The material configuration, position of the metro structure, hydraulic boundary conditions, monitoring frequency, and experimental procedure were kept unchanged. Monitoring points P1, P5, and P7 were selected for the repeatability analysis. The mean and standard deviation were calculated at each sampling time, while the coefficient of variation and maximum relative deviation during the stable stage were used to quantify the dispersion of the experimental results.
Figure 9 presents the repeatability analysis of the pore-water pressure measurements at representative monitoring points P1, P5, and P7 under a hydraulic gradient of 0.07 and a 700 mm2 gravel diversion channel. The three individual repeated tests exhibit similar temporal evolution patterns at all monitoring points. Although slight differences can be observed during the transient adjustment stage, the repeated curves remain closely distributed around their corresponding mean values and gradually converge as the seepage field approaches a new equilibrium.
Figure 9
The relatively narrow standard-deviation bands indicate that the dispersion among the repeated measurements is limited. P1 exhibits the largest pore-pressure magnitude and a more pronounced temporal response because it is located closer to the upstream hydraulic boundary and is directly affected by water-head adjustment. P5, located near the metro station structure, reflects the combined effects of upstream water accumulation, local seepage-path deflection, and increased hydraulic resistance. In comparison, P7 shows a relatively smaller pressure variation, indicating that the blocking-induced disturbance gradually attenuates toward the downstream or transition zone. The results therefore demonstrate that the observed pore-pressure responses are reproducible and are primarily governed by the groundwater-blocking effect rather than random experimental fluctuations.
5 Risk assessment of water level fluctuation
The physical model tests establish a direct basis for the following risk assessment. After the metro station structure was introduced, the original seepage field was clearly redistributed, with water-head accumulation on the upstream side, pore-pressure dissipation on the downstream side, and a transition zone around the structure. This response shows that the maximum water-level rise is a suitable parameter for characterizing the intensity of the groundwater blocking effect. The tests under different working conditions further indicate that the water-level rise is mainly affected by hydraulic gradient, metro structure length, and roof burial depth. The hydraulic gradient controls the seepage driving force, the structure length affects the lateral obstruction range and bypass path, while the roof burial depth changes the effective vertical flow section of the aquifer. On this basis, these three factors were introduced into the PCA–AHP analysis. Thus, the model test results are not only used to explain the blocking mechanism, but also serve as the experimental support for indicator selection, weight determination, and subsequent risk evaluation.
5.1 Risk assessment theory
During the construction and operation of subway stations, the problem of water level blockage caused by subway lines and stations is one of the issues that deserves close attention. At present, although the monitoring technology for groundwater level before and after the subway operation period is relatively complete, the layout of the groundwater flow field monitoring network is relatively complex, with a large amount of data, which is time-consuming and laborious. Therefore, combining risk assessment theory to evaluate the risk of groundwater level blockage caused by subway construction in karst strata is an important approach to addressing the problem of high groundwater levels during subway station operation.
5.2 TOPSIS decision theory
The TOPSIS (Technique for Order Preference by Similarity to an Ideal Solution) method ranks the evaluation objects based on their proximity to the idealized goal, and can evaluate the relative advantages and disadvantages of existing objects. TOPSIS theory, also known as the “ideal point distance method,” belongs to a multi-objective decision-making method. The TOPSIS theory has a high degree of scientificity and operability, and is widely applied by researchers to various engineering problems in various fields (Wu et al., 2020; Haghshenas et al., 2017; Golestanifar et al., 2011; Yazdani-Chamzini and Yakhchali, 2012).
5.2.1 Establishing a decision system
Assuming Um×n is the set of evaluation attribute values, whose matrix form is shown in Equation 9. Among them, the set contains m evaluation indicators Qi(q1,…, qm).
5.2.2 Determine ideal point
The “ideal point” is a key concept in TOPSIS theory that expresses the attributes of decision objects. The “positive ideal point” A+ and “negative ideal point” A− represent the optimal and worst values of the target, respectively. For the positive indicator set (q1,..., qm) and the negative indicator set Qi- (q1,..., qm), the criteria for determining the “positive ideal point” A+and “negative ideal point” A− are shown in Equations 10 and 11.
5.2.3 Ideal point distance calculation
The indicator attribute value and relative distance D are the evaluation criteria for the quality of attributes. To obtain the value of relative distance D, the proximity distance function D(x) is introduced. When the evaluation level of the water level rising is k, the solution formula for the closeness of Value of the ith indicator qi to the ideal point of the index D+i−k and D−i−k are calculated using Equations 12 and 13:
5.2.4 Result evaluation
The ideal-point closeness is calculated using Equation 14:
The final result is determined as the risk level corresponding to the maximum value of closeness, i.e., Pk=maxPi {P1, P2,..., Pl | i=1, 2,..., l}.
5.3 Normal cloud model prediction method
On the basis of traditional fuzzy theory and probability statistics theory, cloud model is a conceptual formalization theory proposed by Academician Li Deyi, reflecting the randomness and fuzziness in the objective world. Cloud models have been successfully applied in areas such as risk prediction and large-scale system evaluation (Lin et al., 2020; Wang et al., 2016, 2022, 2019; Peng et al., 2020).
In the domain space, a cloud model is a pan normal mathematical mapping image generated by two connected normal generators composed of many cloud droplets. It is a scalable and boundaryless cloud image that completes qualitative and quantitative mutual mapping.
With respect to the existence of a fuzzy set A in the domain X, for any element xεX, there exists a random number μA(υ) that has a stabilizing tendency, and μA(υ) is called a degree of affiliation of x to a particular fuzzy set A. If the elements of the domain are simply ordered or can be transformed to be simply ordered by one-to-one mapping, the distribution of the degree of affiliation μA(υ) over X is called a cloud model, or cloud for short. The cloud model has the following basic properties:
(a) The domain can be multi-dimensional;
(b) The certainty of the qualitative concept X exists in the form of a probability distribution, rather than a fixed numerical value;
(c) In terms of quantity, a random implementation is represented as a cloud droplet, and the more cloud droplets there are, the better it reflects the overall characteristics of X;
(d) The greater the certainty of cloud droplets, the greater their contribution to X.
The numerical features of the cloud model are mainly based on the qualitative concepts and quantitative features of the problem expressed by expected Ex, entropy En, and Hyperentropy He, as shown in Figure 10.
Figure 10
Among them, Expected Ex: represents the expected distribution of cloud droplets, is the central value of the universe X, and is reflected on the cloud shape, representing the “highest point” of the cloud shape.
Entropy En: Reflects the span of the cloud represented on the cloud shape. The larger the entropy, the larger the span of the cloud, and the more ambiguous the conceptual range expressed.
Hyperentropy He: Reflects the degree of dispersion of cloud droplets, determined by the fuzziness and randomness of entropy. Reflected in the cloud shape, it refers to the thickness of the cloud. The greater the Hyperentropy, the thicker the cloud, and the stronger the randomness.
5.3.1 The construction steps of a normal cloud model
The forward cloud generator, conditional cloud generator (X conditional cloud generator and Y conditional cloud generator), and reverse cloud generator are all cloud generators that are specific algorithms for generating cloud models. The forward cloud generator exhibits a mapping law of qualitative concepts generating quantitative values. Based on the digital characteristics of normal clouds, cloud droplets that conform to the normal cloud generators are specific algorithms for generating cloud models, including the forward cloud generator, conditional cloud generators (X-condition and Y-condition), and the backward cloud generator. The forward cloud generator implements a qualitative-to-quantitative mapping that produces cloud droplets based on the digital characteristics (Ex, En, He) of a given normal cloud. The number of cloud droplets can be specified according to the practical requirements of the application.
A forward cloud generator is a mapping from qualitative to quantitative, which generates cloud droplets based on the characteristics of the cloud (Ex, En, and He). The calculation steps of the forward cloud generator are described as follows:
Assuming that Z is a quantitative domain represented by precise numerical values, and S is a qualitative concept on Z, if the quantitative value xεZ and x is a random implementation of the qualitative concept S, then entropy En and Hyperentropy He can be calculated. Make x satisfy: x~N (Ex, (En ‘) 2), where En'~N (En, He2), and x membership degree to C, μ (x)ε[0,1] is calculated using Equation 15:
The resulting distribution of x over the domain Z defines a one-dimensional normal cloud, from which the numerical characteristics of the cloud model can be derived.
5.3.2 Screening of indicators
In the risk assessment of water level rise caused by subway station construction, multiple evaluation indicators were selected. Below, we will use Analytic Hierarchy Process (AHP) and Principal Component Analysis (PCA) to explore the correlation between indicators and screen out the main predictive indicators (Kim et al., 2022; Hyun et al., 2015; Khademi Hamidi et al., 2010; Xu et al., 2018; Bouayad and Emeriault, 2017).
5.3.3 Subjective weight
This section introduces the Analytic Hierarchy Process, the specific analysis method is as follows:
5.3.3.1 Constructing discriminant matrix
Assuming that there are m indicators of high risk of groundwater level congestion impacts in the decision-making, using a scientific survey with reference to a large amount of literature as well as a final summary based on the analysis of experts and scholars, the evaluation criteria of the importance of the decision-making indicators use the Arabic numerals from 1 to 9 to rank the importance of the indicators.
5.3.3.2 Solving discriminant matrix
On the discriminant matrix Gm×m uses the maximum eigenvalue solution formula to calculate the maximum eigenvalue λMax and its corresponding feature vector u (Equation 16).
5.3.3.3 Consistency check
The consistency index CI and consistency ratio CR are calculated using Equation 17, with RI denoting the random consistency index.
The reasonableness of the ordering of Gm×m is judged according to CR. CR < 0.1 indicates that Gm×m has good consistency, at which point the subjective weights of the indicators are calculated. The normalized subjective weights are obtained using Equation 18.
Conversely, it indicates that the judgment matrix Gm×m consistency is not met and the importance of the indicators needs to be reordered.
5.3.4 Objective weights
According to the principal component analysis method, calculate the objective weight of the indicators, and the steps are as follows:
A. Assuming that there exist sample objects X with m variables per sample, then a matrix of order m×n can be formed. The sample data matrix is constructed as shown in Equation 19.
The corresponding correlation matrix is given in Equation 20.
B. Calculate the eigenvalues and eigenvectors. Sort feature values as λ1 ≥ λ2≥ …λm > 0, calculate the unit feature vector ei (I = 1, 2,..., m), where eij represents the jth component of the vector. f (i) the information contribution rate of the main component, and F (a) the cumulative contribution rate of the main component. The contribution and cumulative contribution rates are calculated using Equations 21 and 22, respectively.
C. Calculate the weight w “j using the objective indicator weights are calculated using Equation 23 and normalized using Equation 24, and obtain the weight vector W” by normalizing the weight vectors of all indicators.
5.3.5 Weight combination
This section calculates the combination of objective weight set W” and subjective weight set W” using the following method. The subjective and objective weights are combined using Equation 25.
Below, based on the results, delete the indicators with weights less than 0.05 and adjust the indicator set to recalculate the results of the weight combination. Following any indicator screening, the retained weights are renormalized using Equation 26.
Based on the results of principal component analysis, the input indicator set is dimensionally reduced and the main component set F '(i) for the prediction indicator is selected.
5.4 Risk assessment of groundwater level blockage
On the basis of obtaining the comprehensive weights of risk assessment indicators for water level blockage, a water level blockage risk assessment model was established using various methods to conduct relevant research on water level blockage risk warning and engineering control caused by subway station operation period.
5.5 Risk assessment indicators for groundwater level blockage
Before constructing the groundwater-level blockage risk assessment system, the candidate indicators were screened according to the physical mechanism of groundwater seepage disturbance, the structural blocking effect of the metro station, the hydrogeological properties of the aquifer and the availability of engineering parameters. Three principles were followed in the indicator selection. First, the selected indicator should have a clear physical relationship with groundwater blocking and water-level rise. Second, the indicator should be quantifiable from geological investigation, engineering design data, model tests or numerical simulation results. Third, the indicator should be suitable for engineering-scale risk assessment during the construction and operation of metro stations.
According to these principles, six indicators were selected in this study: hydraulic gradient, subway station length, buried depth ratio, aquifer porosity, comprehensive permeability and the angle between the groundwater flow direction and the normal direction of the subway station. Among them, the hydraulic gradient represents the driving force of groundwater seepage; the subway station length reflects the horizontal blocking range of the underground structure; the buried depth ratio describes the degree to which the station structure occupies the aquifer in the vertical direction; aquifer porosity characterizes the groundwater storage capacity; comprehensive permeability reflects the seepage capacity of the strata; and the groundwater flow angle affects the spatial distribution and magnitude of water-level rise around the station structure.
Regional rainfall recharge intensity is important hydrogeological background factors in the Jinan spring area. However, they were not introduced as independent indicators in the present assessment system. Rainfall recharge mainly controls the seasonal fluctuation of groundwater level and the hydraulic head boundary condition. Its influence is therefore reflected indirectly by the hydraulic gradient and groundwater level conditions used in the model tests. In addition, the present study focuses on the engineering-scale groundwater blocking effect caused by the metro station structure, while rainfall recharge intensity and fault-zone proximity are more suitable for regional-scale transient groundwater modeling when sufficient long-term monitoring data are available. Therefore, these factors were considered as background hydrogeological conditions rather than independent risk assessment indicators.
5.5.1 Hydraulic gradient i
The movement of groundwater in the seepage field is complex and variable. The change in groundwater level can reflect the change in groundwater head value, and the indicator to measure its degree of change can be expressed by hydraulic gradient. When the groundwater hydraulic gradient is large, the groundwater flow velocity is high and the kinetic energy is large. Therefore, the hydraulic gradient of groundwater is used as an indicator parameter for risk assessment of water level blockage.
5.5.2 Length of subway station l
The length of underground structures such as subway stations indicates the range of groundwater seepage channels. The longer the subway station length, the wider the range of groundwater bodies it affects, and the greater the risk of water level blockage. Therefore, the length of subway stations is chosen as an indicator parameter for evaluating the risk of groundwater level blockage.
5.5.3 Burial depth ratio of subway stations α
When the main permeable layer of the formation is concentrated and the distribution of the formation is shallow, the construction of subway stations blocks the groundwater runoff channel, often causing significant water level rise and even causing a regional decrease in groundwater flow. The burial depth of subway stations is an important factor affecting groundwater seepage, which can determine the relative position relationship between the aquifer and the subway station. Defining the buried depth ratio of subway stations α, Namely α = h1/h. Among them, h1 is the depth at which the subway station structure is inserted into the aquifer; h is the thickness of the aquifer. As shown in the figure, the larger the burial depth ratio, the more aquifer space is occupied by subway stations, and the greater the risk of water level blockage.
5.5.4 Aquifer porosity p
The karst phenomena such as underground carbonate karst pores and caves are relatively developed in the research area, providing huge storage space and migration channels for groundwater. With the passage of time, the underground karst environment is likely to further develop, leading to the emergence of larger groundwater migration channels. According to the researches, as the porosity increases, the groundwater level rapidly increases and then tends to stabilize. Therefore, the porosity of the aquifer is chosen as the reference factor for the risk of water level blockage.
5.5.5 Comprehensive permeability k
Permeability is an important indicator reflecting the state of water seepage in the formation. Areas with strong permeability in the formation have strong groundwater level fluctuations. The thickness-weighted permeability is calculated using Equation 27.
In the formula: n is the comprehensive permeability (m2); Hi is the thickness of the i-th aquifer (m); Ni is the permeability of the i-th aquifer (m2).
Considering the large differences in permeability coefficients among different strata, the measured permeability coefficient cannot be directly used as a unified quantitative indicator for the water-level backwater analysis. Therefore, a comprehensive permeability capacity index, denoted as kc, is introduced in this study to characterize the relative permeability capacity of different strata. It should be emphasized that kc is a dimensionless normalized evaluation index rather than the measured permeability coefficient.
The measured permeability coefficient is denoted as K. According to the permeability classification criteria listed in Table 4, the permeability grade corresponding to K is first determined and denoted as r. For the r−th permeability grade, and represent the lower and upper limits of the measured permeability coefficient, respectively, while ar and br represent the lower and upper bounds of the corresponding normalized permeability capacity index. The normalized permeability capacity index kc is calculated using Equation 28.
Table 4
| Permeability class | I | II | III | IV | V |
|---|---|---|---|---|---|
| Classification basis | < 10−14 | 10−14~10−13 | 10−13~10−12 | 10−12~10−11 | >10−11 |
| Comprehensive permeability | 0~0.2 | 0.2~0.4 | 0.4~0.6 | 0.6~0.8 | 0.8~1.0 |
| Permeability assessment | Very weak permeability | Weakly permeable | Medium permeability | Highly permeable | Extremely permeable |
Rating of soil permeability.
where K is the measured permeability coefficient of the stratum; (r) is the permeability grade determined according to Table 4. and are the lower and upper limits of the measured permeability coefficient for the r−th grade, respectively; and ar and br are the lower and upper bounds of the normalized permeability capacity index corresponding to the r−th grade, respectively. The logarithmic form is adopted because the permeability coefficients of different strata may vary by several orders of magnitude. This treatment reduces the influence of magnitude differences and allows the permeability capacity of different strata to be compared within a unified evaluation framework. It should be noted that kc is a normalized evaluation index rather than the measured permeability coefficient. This index is used to quantify the permeability capacity of different strata and to support the subsequent analysis of the groundwater blocking effect. According to the Table 4, the permeability level of the soil can be determined.
5.5.6 The angle between the flow direction of groundwater and the normal direction of subway stations θ
It was found that due to the angle between the groundwater flow direction and the normal direction of the subway station, the maximum water level backwater on the upstream surface does not appear in the central position, but deviates. So the angle between the flow direction of groundwater and the normal direction of subway stations affects the location, size, and distribution of water level rise.
5.6 Classification of risk levels and risk expression for water level blockage
In determining the values of the index attributes, hydraulic gradient i, aquifer porosity p, and integrated permeability k can be obtained from the geological survey data. The length l of the subway station, the buried depth ratio α of the subway station, and the angle θ between the direction of groundwater flow and the normal direction of the subway station can be obtained from the relevant engineering data at the time of the construction of the subway station.
According to the characteristics of the project, the classification criteria for the risk level of water level blockage during the operation period of subway stations are selected, which are divided into five levels: extremely low risk (I), low risk (II), medium risk (III), high risk (IV), and extremely high risk (V). The corresponding risk status is represented by the risk level of water level blockage Cl (l = 0.2, 0.4,... L). By studying relevant research materials and conducting engineering case investigations, the values of each evaluation index were evenly divided, and the grading standards are shown in Table 5. Based on actual engineering analysis and research, corresponding descriptions have been given for the phenomenon of water level backwater at different risk levels.
Table 5
| Level | (I) | (II) | (III) | (IV) | (V) |
|---|---|---|---|---|---|
| Hydraulic gradient: i | < 0.01 | 0.01~0.02 | 0.02~0.03 | 0.03~0.04 | >0.04 |
| Length of metro stations: l/(m) | < 150 | 150~250 | 250~350 | 350~450 | >450 |
| Buried depth ratio: α | < 0.3 | 0.3~0.4 | 0.4~0.5 | 0.5~0.6 | >0.6 |
| Aquifer porosity: p | < 0.1 | 0.1~0.2 | 0.2~0.3 | 0.3~0.4 | >0.4 |
| Comprehensive permeability index | 0~0.2 | 0.2~0.4 | 0.4~0.6 | 0.6~0.8 | 0.8~1.0 |
| Groundwater flow angle | >60 | 45~60 | 30~45 | 15~30 | 0~15 |
| Discrete value | 0.2 | 0.4 | 0.6 | 0.8 | 1.0 |
| Qualitative risk description | Very low risk | Low risk | Medium risk | High risk | Very high risk |
Classification of high risk of water level obstruction caused by subway station construction.
Based on the results of numerical simulation research and experimental result, the degree of water level rise and the degree of water pressure change on the structural bottom plate are used as characterization parameters to describe the risk level of water level rise (see Table 6).
Table 6
| Risk level | Expression of high risk of congestion at water level |
|---|---|
| Level I | The risk of water level congestion is extremely low, with an average water level congestion of less than 0.2 m, a maximum water level congestion of less than 0.3 m, and a variation in water pressure on the structure floor of less than 3 kPa. |
| Level II | The risk of water level congestion is low, with an average water level congestion of 0.2–0.6 m, a maximum water level congestion of 0.3–0.8m, and a variation of water pressure on the structural floor of 3–7 kPa. |
| Level III | The risk of water level congestion is moderate, with an average water level congestion of 0.6 to 1.0 m, a maximum water level congestion of 0.8 to 1.5 m, and a variation of water pressure on the structural floor of 7 to 15 kPa. |
| Level IV | The risk of water level congestion is high, with an average water level congestion of 1.0~1.5 m, a maximum water level congestion of 1.5~2.0 m, and a water pressure variation of 15~20 kPa at the base of the structure. |
| Level V | The risk of water level congestion is extremely high, with average water level congestion greater than 1.5 m, maximum water level congestion greater than 2.0 m, and water pressure variability greater than 20 kPa at the base of the structure. |
Description of high-risk level of water level raising.
According to the proposed risk assessment system, combined with the measured dataset of indicators, the TOPSIS decision theory and normal cloud model prediction method are used to construct the prediction model. Afterwards, actual data was used to solve the problem, and the predicted results were compared with the actual situation to select the optimal risk assessment system for water level blockage.
5.7 Indicator weight set
5.7.1 Subjective weight w'i
In the process of calculating the subjective weights of the indicators, the importance ranking of the selected indicators was determined by means of consulting relevant information, and after systematic discussion and consultation finally the importance ranking table of the decision-making indicators was obtained, as shown in Table 7.
Table 7
| Indicator | i | l | α | p | k | θ |
|---|---|---|---|---|---|---|
| i | 1 | 4 | 1/2 | 2 | 4 | 2 |
| l | 1/4 | 1 | 1/3 | 1/2 | 1 | 1/2 |
| α | 1/2 | 3 | 1 | 3/2 | 3 | 3/2 |
| p | 1/2 | 2 | 2/3 | 1 | 2 | 1 |
| k | 1/4 | 1 | 1/3 | 1/2 | 1 | 2 |
| θ | 1/2 | 2 | 2/3 | 1 | 2 | 1 |
Subjective importance ranking.
According to the subjective importance ranking table, the subjective weight set is W'{0.3165, 0.0814, 0.2176, 0.1232, 0.0871, 0.1742}. Among them, the consistency test parameter CR = 0.027 < 0.10, calculated indicates that the importance ranking of indicators is very reasonable (see Figure 11).
Figure 11
5.7.2 Objective weight w “j
Real data on evaluation indicators were collected through model test, and these data were summarized as data samples for objective weight analysis, as shown in Table 8.
Table 8
| i | l/(m) | α | p | k | θ/(°) |
|---|---|---|---|---|---|
| 0.026 | 280 | 0.511 | 0.11 | 0.42 | 45 |
| 0.031 | 320 | 0.351 | 0.32 | 0.68 | 18 |
| 0.024 | 360 | 0.423 | 0.41 | 0.47 | 25 |
| 0.020 | 410 | 0.512 | 0.20 | 0.71 | 21 |
| 0.027 | 203 | 0.342 | 0.33 | 0.29 | 25 |
| 0.041 | 361 | 0.127 | 0.17 | 0.82 | 40 |
| 0.043 | 312 | 0.621 | 0.52 | 0.48 | 5 |
| 0.036 | 362 | 0.736 | 0.15 | 0.69 | 32 |
| 0.042 | 274 | 0.421 | 0.41 | 0.67 | 26 |
| 0.038 | 368 | 0.361 | 0.33 | 0.46 | 16 |
| 0.051 | 286 | 0.496 | 0.18 | 0.66 | 8 |
| 0.044 | 295 | 0.571 | 0.54 | 0.51 | 17 |
| 0.035 | 365 | 0.612 | 0.43 | 0.66 | 76 |
| 0.040 | 342 | 0.492 | 0.14 | 0.44 | 0 |
| 0.028 | 359 | 0.421 | 0.03 | 0.22 | 22 |
| 0.022 | 312 | 0.352 | 0.38 | 0.47 | 50 |
| 0.026 | 280 | 0.511 | 0.11 | 0.42 | 45 |
| 0.021 | 361 | 0.327 | 0.24 | 0.61 | 15 |
Data of groundwater parameters.
According to the principle and method of principal component analysis, the above six indicators were analyzed and calculated according to the equations, and the objective weights of the six data items were obtained as shown in Table 9 (see Figure 12).
Table 9
| Type of indicator | i | l | α | p | k | θ |
|---|---|---|---|---|---|---|
| w”j | 0.1285 | 0.2406 | 0.1329 | 0.1621 | 0.1785 | 0.1573 |
Weight results of principal component analysis.
Figure 12
5.7.3 Combination weight Wi
The objective weight set W‘ obtained by the PCA method and the subjective weight set W' obtained by the Analytic Hierarchy Process were combined by multiplication using the method described, and the comprehensive weight set Wi {0.2674, 0.1288, 0.1901, 0.1313, 0.1022, 0.1801} was obtained through weight allocation (see Table 10 and Figure 13).
Table 10
| Type of indicator | i | l | α | P | k | θ |
|---|---|---|---|---|---|---|
| Subjective weighting | 0.3165 | 0.0814 | 0.2176 | 0.1232 | 0.0871 | 0.1742 |
| Objective weighting | 0.1285 | 0.2406 | 0.1329 | 0.1621 | 0.1785 | 0.1573 |
| Combined weights | 0.2674 | 0.1288 | 0.1901 | 0.1313 | 0.1022 | 0.1801 |
Comprehensive weight calculation table.
Figure 13
5.8 Model application and assessment
In practical engineering, the standard for assessing the effectiveness of model services is to evaluate the applicability and accuracy of the model. 12 sets of real data for evaluating the risk of groundwater level blockage were selected, and the TOPSIS theoretical model and normal cloud model prediction method were used to comprehensively evaluate the risk of groundwater level blockage (Table 11). Finally, the evaluation results were compared and verified to evaluate the applicability of the model.
Table 11
| i | l/(m) | α | p | k | θ/(°) |
|---|---|---|---|---|---|
| 0.031 | 320 | 0.351 | 0.32 | 0.68 | 18 |
| 0.026 | 280 | 0.511 | 0.11 | 0.42 | 45 |
| 0.024 | 360 | 0.423 | 0.41 | 0.47 | 25 |
| 0.020 | 410 | 0.512 | 0.20 | 0.71 | 21 |
| 0.027 | 203 | 0.342 | 0.33 | 0.29 | 25 |
| 0.041 | 361 | 0.127 | 0.17 | 0.82 | 40 |
| 0.043 | 312 | 0.621 | 0.52 | 0.48 | 5 |
| 0.036 | 362 | 0.736 | 0.15 | 0.69 | 32 |
| 0.042 | 274 | 0.421 | 0.41 | 0.67 | 26 |
| 0.038 | 368 | 0.361 | 0.33 | 0.46 | 16 |
| 0.051 | 286 | 0.496 | 0.18 | 0.66 | 8 |
| 0.044 | 295 | 0.571 | 0.54 | 0.51 | 17 |
Samples of data to be evaluated.
Firstly, the evaluation process is based on a normal cloud model. Three numerical features (Ex, En, and He) were calculated, and then the corresponding cloud droplets were generated using the forward cloud generator algorithm using MATLAB, as shown in Figure 14.
Figure 14
According to the theoretical framework described in the previous section, the water-level backwater risk levels were evaluated using the TOPSIS method and the normal cloud model. To examine the engineering applicability of the evaluation results, 12 validation cases were compared with the corresponding reference results. As shown in Figure 15, the agreement rate between the normal cloud model and the reference results was 75.00% (9 out of 12 cases), while that of the TOPSIS method was 58.33% (7 out of 12 cases).
Figure 15
It should be noted that the number of validation cases is limited. Therefore, the difference between the two agreement rates should not be interpreted as statistically significant. This comparison is used only as a qualitative engineering-based consistency check, rather than as formal statistical evidence of model superiority. From the distribution trend shown in Figure 15, the TOPSIS evaluation results tend to be relatively conservative, whereas the normal cloud model shows better consistency with the reference results within the limited validation dataset. Overall, the comparison suggests that the normal cloud model can reasonably reflect the main trend of the water-level backwater risk in the present cases. However, due to the small number of validation samples, its applicability should be further verified using more engineering cases, field monitoring data, or numerical simulation results in future studies.
6 Discussion
The metro station structure reduced the effective seepage section and increased local flow resistance, causing upstream water-head accumulation and downstream pressure reduction. The pore-pressure curves show that the seepage field underwent a clear adjustment process before reaching a new equilibrium through lateral and vertical bypass flow. The repeated tests at P1, P5, and P7 showed similar trends and limited dispersion, supporting the reliability of the measured pore-pressure response.
All diversion measures reduced the water-level rise, but their effectiveness varied with hydraulic capacity. The 3000 mm2 gravel channel performed best, while the 700 mm2 channel and the connecting-pipe scheme achieved comparable reductions with smaller sections. This suggests that the benefit of increasing the diversion area becomes limited once sufficient hydraulic connectivity is restored. In practice, hydraulic performance should therefore be considered together with construction space, maintenance, clogging risk, and cost. The risk assessment also identified hydraulic gradient as the most influential factor. Although the normal cloud model agreed better with the reference cases than TOPSIS, the limited number of validation samples means that this result should be treated cautiously.
The physical model was intended to reproduce the local blocking effect around the metro station rather than the full regional karst groundwater system. Actual groundwater flow in spring areas may be controlled by conduits, fractures, subterranean rivers, and preferential pathways, which may not follow Darcy flow. The model also simplifies aquifer heterogeneity, conduit connectivity, and temporal changes in recharge and discharge. Therefore, the results mainly describe the local mechanisms of water-head accumulation and seepage redistribution. Engineering application still requires site-specific investigation, field monitoring, and numerical modeling that considers fracture–conduit flow and possible non-Darcy effects.
7 Conclusions
In this study, data processing and analysis were conducted on groundwater diversion measures under six working conditions after subway model excavation. The pore water pressure and settlement during the excavation process were also monitored and analyzed. The main conclusions are as follows:
A significant water-level rise occurred in the subway station model when no diversion measure was adopted. Taking the hydraulic gradient of 0.07 as an example, the measured water-level backwater at monitoring points P3, P4 and P5 on the upstream side of the station model reached 2.10 m, 2.02 m and 2.00 m, respectively. Among them, P3 was located near the middle of the upstream side and recorded the maximum water-level rise. The P7 and P11 sensors measured water-level backwater heights of 1.12 m and 1.14 m, respectively, indicating that groundwater flow around the station model was still present. In contrast, the P10 sensor on the downstream side recorded a groundwater-level decrease of 0.14 m, which was mainly attributed to the blocking effect of the subway station structure on the original groundwater runoff channel.
The groundwater diversion measures effectively reduced the water-level backwater induced by the station structure. Under different hydraulic gradients, the 300 mm2 gravel channel produced the highest residual water-level backwater, while the 3000 mm2 gravel channel produced the lowest residual water-level backwater. Overall, the diversion efficiency can be ranked as follows: 3000 mm2 gravel channel > 700 mm2 gravel channel > seven 5 mm diameter connecting pipes > 500 mm2 gravel channel > 300 mm2 gravel channel. The effects of the 700 mm2 gravel channel and the seven 5 mm diameter connecting pipes were relatively close to the minimum backwater condition, indicating that both measures can effectively alleviate the groundwater blocking effect.
Six parameters, namely hydraulic gradient, subway station length, buried depth ratio, aquifer porosity, comprehensive permeability and groundwater flow angle, were selected as the risk assessment indicators for groundwater-level blockage. The combined weights obtained using AHP and PCA showed that the hydraulic gradient had the largest weight, with a value of 0.2674, while the comprehensive permeability had the smallest weight, with a value of 0.1022. This indicates that hydraulic gradient is the most sensitive factor affecting the water-level blockage risk in the studied case.
The TOPSIS method and the normal cloud model were used to establish the groundwater-level blockage risk assessment model. Compared with TOPSIS, the normal cloud model showed better agreement with the model test results, indicating that it is more suitable for evaluating the uncertainty and fuzziness of groundwater-level blockage risk. Based on the risk assessment results, corresponding diversion measures can be selected for different risk levels, providing a reference for groundwater control and spring protection in similar metro construction projects.
Statements
Data availability statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
Author contributions
YG: Supervision, Writing – review & editing, Writing – original draft, Methodology. LD: Writing – original draft, Conceptualization, Investigation. RW: Data curation, Writing – review & editing, Conceptualization, Formal analysis, Investigation. JP: Writing – review & editing, Data curation, Project administration, Conceptualization. RZ: Resources, Funding acquisition, Conceptualization, Writing – review & editing. HZ: Writing – review & editing, Project administration, Resources, Funding acquisition. ZZ: Software, Supervision, Resources, Writing – review & editing. TH: Methodology, Writing – review & editing, Project administration, Funding acquisition. CJ: Visualization, Writing – review & editing, Investigation, Conceptualization, Supervision, Software.
Funding
The author(s) declared that financial support was received for this work and/or its publication. This study was financially supported by Natural Science Foundation of Shandong Province, China (ZR2023QE265), Shandong Provincial Transportation Technology Plan (2024B02), City of Springs Industry Leading Talents Support Program (Ji Gov [2020] 90), and Jinan Science and Technology Plan Social Livelihood Special Project (202131001).
Conflict of interest
LD, RZ, and HZ were employed by Jinan Rail Transit Group Construction Investment Co., Ltd.
The remaining author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
BouayadD.EmeriaultF. (2017). Modeling the relationship between ground surface settlements induced by shield tunneling and the operational and geological parameters based on the hybrid PCA/ANFIS method. Tunn. Undergr. Sp. Tech.68, 142–152. doi: 10.1016/j.tust.2017.03.011
2
ChenF.WangY.JiangW.ZhengS. (2021). Numerical simulation of ground movement induced by water and sand gushing in subway through fault based on DEM-CFD. Comput. Geotech.139:104282. doi: 10.1016/j.compgeo.2021.104282
3
GolestanifarM.GoshtasbiK.JafarianM.AdnaniS. (2011). A multi-dimensional approach to the assessment of tunnel excavation methods. Int. J. Rock Mech. Min. Sci.48, 1077–1085. doi: 10.1016/j.ijrmms.2011.07.001
4
HaghshenasS. S.MikaeilR.ArdalanT.SedaghatiZ.Kazemzadeh HerisP. (2017). Selection of an appropriate tunnel boring machine using TOPSIS-FDAHP method (Case Study: Line 7 of Tehran Subway, East-West Section). Electron. J. Geotech. Eng.22, 4047–4062.
5
HeC.WangB. (2013). Research progress and development trends of highway tunnels in China. J. Mod. Transp.21, 209–223. doi: 10.1007/s40534-013-0029-4
6
HyunK. C.MinS.ChoiH.ParkJ.Lee IM. (2015). Risk analysis using fault-tree analysis (FTA) and analytic hierarchy process (AHP) applicable to shield TBM tunnels. Tunn. Undergr. Sp. Tech.49, 121–129. doi: 10.1016/j.tust.2015.04.007
7
Khademi HamidiJ.ShahriarK.RezaiB.RostamiJ.BejariH. (2010). Risk assessment based selection of rock TBM for adverse geological conditions using Fuzzy-AHP. Bull. Eng. Geol. Environ.69, 523–532. doi: 10.1007/s10064-009-0260-8
8
KimJ.KimC.KimG.KimI.AbbasQ.LeeJ. (2022). Probabilistic tunnel collapse risk evaluation model using analytical hierarchy process (AHP) and Delphi survey technique. Tunn. Undergr. Sp. Tech.120:104262. doi: 10.1016/j.tust.2021.104262
9
KongF.XueY.GongH.JiangX.FuK.HanM. (2026). Modeling dynamic fracturing behavior of water-resisting rock of tunnel under seismicity based on a coupled hydro-mechanical discrete element method. Rock. Mech. Rock. Eng. doi: 10.1007/s00603-026-05380-8
10
LinC. J.ZhangM.LiL. P.ZhouZ. Q.LiuS.LiuC.et al. (2020). Risk assessment of tunnel construction based on improved cloud model. J. Perform. Constr. Fac.34. doi: 10.1061/(ASCE)CF.1943-5509.0001421
11
LiuZ.MaX.ZhangH.SongQ.ChenY.MaC. (2025). Seismic response characteristics of subway stations in the Jinan area: an experimental and computational approach. J. Earthq. Eng.29, 2035–2066. doi: 10.1080/13632469.2025.2484588
12
LoK. Y.RamsayJ. A. (1991). The effect of construction on existing subway tunnels—a case study from Toronto. Tunn. Undergr. Sp. Tech.6, 287–297. doi: 10.1016/0886-7798(91)90140-Y
13
LuD.LiX.DuX.LinQ.GongQ. (2020). Numerical simulation and analysis on the mechanical responses of the urban existing subway tunnel during the rising groundwater. Tunn. Undergr. Sp. Tech.98, 103297.1–103297.12. doi: 10.1016/j.tust.2020.103297
14
PengY.WuL.ZuoQ.ChenC.HaoY. (2020). Risk assessment of water inrush in tunnel through water-rich fault based on AHP-cloud model. Geomat. Nat. Haz. Risk11, 301–317. doi: 10.1080/19475705.2020.1722760
15
RicciG.EnrioneR.EusebioA.CrovaR. (2007). Numerical Modelling of the Interference between Underground Structures and Aquifers in Urban Environment. The Turin Subway Line 1. Underground Space. London: Taylor and Francis Group. p.1323–1329.
16
SongW.DongJ.LiuD. (2014). “Studies on the mechanical model of subway station structures under the influence of changes in groundwater level”, in Challenges and Advances in Sustainable Transportation Systems, p. 413–419. doi: 10.1061/9780784413364.051
17
TongH.PengJ. F.ZhangY. J.FangT. G.ZhangJ. S.MenZ. Y.et al. (2021). Environmental benefit analysis of “road-to-rail” policy in China based on a railway tunnel measurement. J. Clean. Prod.316:128227. doi: 10.1016/j.jclepro.2021.128227
18
WangY. CYinX.JingH. WLiuR. CSuH. J. (2016). A novel cloud model for risk analysis of water inrush in karst tunnels. Environ. Earth Sci.75, 1–13. doi: 10.1007/s12665-016-6260-7
19
WangP.XueY.SuM.QiuD.LiG. (2022). A TBM tunnel collapse risk prediction model based on AHP and normal cloud model. Geomech. Eng.30, 413–422. doi: 10.12989/gae.2022.30.5.413
20
WangX.LiS.XuZ.HuJ.PanD.XueY. (2019). Risk assessment of water inrush in karst tunnels excavation based on normal cloud model. B. Eng. Geol. Environ.78, 3783–3798. doi: 10.1007/s10064-018-1294-6
21
WuB.LuM.HuangW.LanY.WuY.HuangZ. (2020). A case study on the construction optimization decision scheme of urban subway tunnel based on the TOPSIS method. KSCE J. Civ. Eng.24, 3488–3500. doi: 10.1007/s12205-020-1290-9
22
XuJ. B.ChenJ. P.WuS. L.PanY. H.WangW.LuoQ. Q. (2018). Prediction of large deformation behavior in tunnels based on AHP-FUZZY method and numerical simulation method. Geotech. Geol. Eng.36, 151–163. doi: 10.1007/s10706-017-0312-y
23
Yazdani-ChamziniA.YakhchaliS. H. (2012). Tunnel Boring Machine (TBM) selection using fuzzy multicriteria decision making methods. Tunn. Undergr. Sp. Tech.30, 194–204. doi: 10.1016/j.tust.2012.02.021
24
YuH.XuS.YinX.HasanipanahM. (2026). A sliding window feature extraction and weight adaptive random forest-based method for TBM tunnel rock mass grade identification. Expert Syst. Appl.311:131336. doi: 10.1016/j.eswa.2026.131336
25
ZhangS.GaoJ.LiuC.LiP.YangZ.LuX. (2024). Model test on the collapse mechanism of subway tunnels in the soil-sand-rock composite strata. Eng. Fail. Anal.162:108356. doi: 10.1016/j.engfailanal.2024.108356
26
ZhouZ.IrizarryJ.GuoW. (2021). A network-based approach to modeling safety accidents and causations within the context of subway construction project management. Safety Sci.139:105261. doi: 10.1016/j.ssci.2021.105261
Summary
Keywords
groundwater level rise, groundwater blocking, physical model testing, metro station, TOPSIS, normal cloud model
Citation
Gao Y, Du L, Wang R, Pei J, Zhang R, Zhang H, Zhang Z, Hu T and Jia C (2026) Research on risk assessment and control of water level rising during operation of Jinan Metro based on similar physical model experiments. Front. Water 8:1881917. doi: 10.3389/frwa.2026.1881917
Received
15 May 2026
Revised
05 September 2026
Accepted
01 October 2026
Published
03 November 2026
Volume
8 - 2026
Edited by
Pragnaditya Malakar, Indian Institute of Science Education and Research Berhampur (IISER), India
Reviewed by
Zhongyuan Xu, Southwest Jiaotong University, China
Jiajun Shu, China University of Mining and Technology, Beijing, China
Updates
Copyright
© 2026 Gao, Du, Wang, Pei, Zhang, Zhang, Zhang, Hu and Jia.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Chao Jia, jiachao@sdu.edu.cn
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.