Abstract
Wastewater treatment plants (WWTPs) are potential reservoirs and dissemination pathways for antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) into aquatic environments. Most South African WWTPs use activated sludge processes that may incompletely remove ARB and ARGs, potentially contributing to environmental antimicrobial resistance (AMR). This study investigated physicochemical parameters, bacterial occurrence, antimicrobial susceptibility, and genomic characteristics of presumptive Enterococcus and Staphylococcus spp. from two WWTPs and receiving rivers in Gauteng, South Africa. Effluent physicochemical parameters remained within regulatory pH and temperature ranges (pH 7.25–7.51; temperature 16.73–22.33 °C), with DO increasing (26.77–125%) and TDS ranging from 170–326 ppm. Seventy-two water samples were collected from influent, effluent, upstream, and downstream sites during three sampling periods in June, August, and late October 2023. Target bacteria were enumerated by membrane filtration and selective culture, followed by biochemical identification and antimicrobial susceptibility testing (AST). Presumptive Enterococcus and Staphylococcus concentrations ranged from 6.074–7.423 and 6.576–7.255 log CFU/mL, respectively. WWTP1 showed limited bacterial removal (0.68–10.76%), whereas WWTP2 achieved 89.5–90.5% reduction; downstream concentrations generally exceeded upstream levels. From 54 isolates subjected to AST, six met the predefined MDR criterion. Enterococcus isolates exhibited resistance to teicoplanin, azithromycin, and tetracycline. Whole-genome sequencing identified four E. faecium sequence types (ST1052, ST1058, ST94, and ST32) and one MDR S. aureus sequence type (ST243). E. faecium harboured msr(C), erm(B), and lsa(A), while S. aureus carried norA and norR. Overall, detection of MDR bacteria and clinically relevant resistance determinants in treated wastewater and receiving rivers indicates potential WWTP-associated environmental dissemination of resistant bacteria in aquatic environments.
Introduction
Antibiotic resistance (AR) has emerged as one of the most pressing global public health threats driven by the persistent overuse, misuse, and improper disposal of antibiotics (Salam et al., 2023). Environmental bacterial isolates are increasingly become antibiotic resistant bacteria (ARB), reducing the therapeutic effectiveness of antibiotics contributing to treatment failure (Friedman et al., 2016). Currently, AR is recognised as a silent and faceless pandemic that continues to increase globally, threatening human, animal, and environmental health (Jampani and Chandy, 2021; Mahoney et al., 2021). Recent surveillance from the World Health Organisation (WHO) by the Global Antibiotic Resistance Surveillance (GLASS) report estimates that 1 in 6 bacterial infections globally show resistance to commonly used antibiotics (World Health Organization, 2025). Consequently, bacteria are rapidly acquiring AR to currently available antibiotics, increasing morbidity, mortality, and healthcare costs. Therefore, there is an urgent need to identify environmental reservoirs and transmission pathways that contribute to the persistence and spread of ARB and antibiotic resistance genes (ARGs).
Wastewater treatment plants (WWTPs) are increasingly recognised as critical environmental hotspots for the emergence and transmission of ARB and ARGs (Gholizadeh et al., 2023; La Rosa et al., 2025a). The treatment plants receive wastewater contaminated with antibiotics, ARB, and ARGs from hospitals, households, veterinary and agricultural activities, and pharmaceutical industries. A recent general screening using LC–MS identified 36 antibiotic pollutants across two South Africa WWTPs, highlighting the need for monitoring AR determinants in wastewater (Mokhonoana et al., 2026). Typically, wastewater contain high bacterial densities and a diversity of extracellular genetic elements (plasmids, transposons, integrons, and free-floating DNA-that carry ARG) that can be transferred among bacteria via horizontal gene transfer mechanisms (transformation and conjugation) (Brown et al., 2024; La Rosa et al., 2025b). Nutrient rich conditions in WWTPs promotes bacterial growth and horizontal gene transfer, while incompletely metabolised antibiotic pollutants in wastewater create selective pressure that favours ARB (Olanrewaju and Bezuidenhout, 2025; Polianciuc et al., 2020; Sambaza and Naicker, 2023; Tucker et al., 2022). Therefore, WWTPs acts as exchange point, amplification point and transmission pathway of ARGs among bacteria into the environment.
In South African, WWTPs predominantly uses conventional treatment technologies such as activated sludge, wastewater ponds, wetlands, bio filters and rotating biological reactors (Korzeniewska and Harnisz, 2018; Jack et al., 2016). While these processes are effective in removing biodegradable organic matter that often deplete oxygen in receiving water. However, these technologies do not fully remove antibiotic pollutants, ARB and ARGs from WWTPs effluents (Alam et al., 2021). These treatment technologies primarily use on adsorption, biodegradation, and partial microbial inactivation rather complete destruction of contaminants. As results, treated effluents containing ARB and ARGs are discharged into rivers contributing to the environmental spread of AR.
The challenge of wastewater associated AR is particularly concerning in South Africa, where many WWTPs operate under sub-optimal conditions. The 2023 Green Drop Report by the Department of Water and Sanitation, 334 (39%) of the audited WWTPs were classified as being in a critical state requiring urgent intervention (Department of Water and Sanitation, 2023). These challenges are due to ageing infrastructure, inadequate maintenance, and vandalism compromising the wastewater treatment efficiency, and causing inadequately treated effluents to be released into rivers. The public health implications of poor wastewater management have been demonstrated by recent outbreaks such as the Hammanskraal cholera outbreak in northern Pretoria, South Africa (du Plessis et al., 2024). This growing burden threatens progress towards Sustainable Development Goals (SDGs) 3 and 6, which focus on good health, well-being, clean water, and sanitation, while indirectly contributing to poverty and inequality associated with SDG 1. Despite increasing awareness of AMR, significant knowledge gaps remain regarding the diversity, distribution, and genomic characteristics of ARB and ARGs in South African aquatic environments.
Therefore, this study aimed to characterise the occurrence and concentration of presumptive Enterococcus spp. and Staphylococcus spp. in influent, effluent, upstream and downstream waters associated with two WWTPs in Gauteng, South Africa, during three sampling periods in 2023. The specific objectives were to: (i) quantify the target organisms using culture-based methods and compare their concentrations among WWTPs, sampling points and sampling campaigns; (ii) determine phenotypic antimicrobial susceptibility profiles to identify isolates multidrug-resistant (MDR) isolates and (iii) characterise the sequence types, resistance determinants and virulence-associated genes of six selected MDR isolates using whole-genome sequencing (WGS). The study contributes to enhanced genomic surveillance and a better understanding of environmental AR dynamics in South Africa.
Materials and methods
Study area description
Two wastewater treatment plants receiving municipal and hospital wastewater in Johannesburg, South Africa, were selected for this study and are referred to as WWTP1 and WWTP2 (Figure 1). Johannesburg was selected because of its high population density and extensive economic activity. WWTP1 treats domestic sewage using an activated sludge process followed by chlorination, with a design capacity of 150,000 kL per day. While WWTP2 treats domestic sewage using activated sludge, maturation ponds, and chlorination, and has a design capacity of 405,000 kL per day. Water samples were collected from the influent, effluent, upstream river, and downstream river at each WWTP. Based on the South African seasonal calendar, June and August fall within winter, whereas late October falls within spring. However, the three sampling periods were not treated as seasons but as sampling periods. During each sampling period, triplicate water samples were collected from each sampling point using sterile 500-mL glass bottles. A total of 72 samples were collected in this study. The samples were transported in cooler boxes maintained at 4 °C to the University of South Africa, Florida Park, Roodepoort Campus, for further processing.
Figure 1
Physicochemical parameter analysis in water
Water quality at the sampling sites was assessed by measuring physicochemical parameters in situ during each sampling event. The physicochemical parameters including water temperature, potential hydrogen (pH), total dissolved solids (TDS), and dissolved oxygen (DO), were measured using a multiparameter Lovibond SensoDirect 150 (Lasec, South Africa). Triplicate measurements were recorded for each parameter at each sampling point. Before measurements were taken, the Lovibond SensoDirect 150 meter was calibrated according to the manufacturer’s instructions.
Isolation and quantification of bacteria
From each 500 mL sample, bacteria were concentrated by vacuum filtration through sterile 0.45 μm nitrocellulose membrane filters (Merck, South Africa) using a Merck filtration manifold. The membrane filter was then aseptically transferred into 10 mL sterile distilled water using sterile forceps, and the bacterial cells were gently resuspended by rubbing the membranes with sterile inoculating loop. Enterococcus selective agar (Merck) and mannitol salt phenol-red agar (Merck) were used for isolation and enumeration of presumptive Enterococcus and Staphylococcus, respectively. Serial dilutions up to 10−7 were prepared, and each dilution was plated in triplicate onto the respective media. Plates were incubated at 37 °C for 24 h. Presumptive Enterococcus colonies appeared pink to dark red on Enterococcus selective agar; presumptive S. aureus colonies appeared yellow on mannitol salt phenol-red agar.
Presumptive colonies were counted and recorded, and bacterial concentrations in the original samples were calculated using Equation 1. Data analysis was performed using Origin 2021 software to determine the mean, standard deviation and standard error. Percentage reduction between influent and effluent samples, as well between upstream and downstream river samples for WWTPs were calculated using Equations 2, 3, respectively. The identity of presumptive bacteria was confirmed using biochemical tests such as oxidase, catalase citrate, and Gram staining. In all experiments, Enterococcus faecalis ATCC 29212, Enterococcus faecium ATCC 700221, and Staphylococcus aureus ATCC 25923 were used as positive controls. Presumptive colonies were counted, and bacterial concentrations in the original samples were calculated as:
Where = bacterial concentration (CFU mL−1), = colonies counted per plate (CFU), = total dilution factor, and = volume plated (mL).
Non-detects were recorded as 0 CFU/mL in the raw dataset. Given an analytical detection limit of 10 CFU/mL, non-detects were assigned half the detection limit (5 CFU/mL) for log10 transformation. Percentage reduction between influent and effluent, and between upstream and downstream, was calculated as:
And,
Where negative values indicate an increase in bacterial counts downstream.
Antimicrobial susceptibility testing
Antimicrobial susceptibility testing was performed using the Kirby–Bauer disk diffusion method in accordance with CLSI guidelines (M100, 33rd ed., 2023), with separate antibiotic panels for Gram-positive and Gram-negative ESKAPE isolates. Pure cultures revived from −20 °C glycerol stocks were grown overnight in nutrient broth at 37 °C, and inocula were adjusted to a 0.5 McFarland standard (~1 × 108 CFU mL−1) by measuring absorbance at 625 nm (0.08–0.13) using an Evolution 60S UV–Vis spectrophotometer, with suspensions used within 15 min. A total of 54 presumptive E. faecium, and S. aureus strains were tested in triplicate. The antibiotics selected for testing were based on those commonly prescribed and previously detected in South African WWTPs, representing different antibiotic classes. The panel included antibiotics used for empirical therapy as well as those considered as last resort options. Mueller–Hinton agar plates were inoculated to produce bacterial lawns, and a maximum of five antibiotic disks per 10 cm plate were aseptically applied; plates were incubated aerobically at 37 °C for 16–18 h. Quality control was performed on each testing using Staphylococcus aureus ATCC 25923, and Enterococcus faecalis ATCC 29212, with zone diameters falling within CLSI-recommended ranges. Inhibition zones were measured to the nearest millimetre and interpreted as susceptible, intermediate, or resistant using CLSI M100 (2023). Only antibiotic–organism combinations with validated interpretive criteria were categorised and isolates non-susceptible to at least one agent in three or more antimicrobial classes were defined as multidrug-resistant. Multiple antibiotic resistance (MAR) index for the isolates was calculated using Equation 4. Six isolates with higher MAR were selected for further characterisation by whole genome sequencing.
MAR = a/b Equation 4 where a = the number of antibiotics to which the isolate is resistant, and b = total number of antibiotics tested against that isolate.
Whole-genome sequencing
Multidrug resistant isolates with high MAR indices were selected for WGS. Due to cost constraints, six MDR isolates (five presumptive E. faecium and one presumptive S. aureus) were sequenced. Single colonies were inoculated into 5 mL LB broth and incubated for 24 h. Genomic DNA was extracted using the Quick DNA Fungal/Bacterial Microprep Kit (Zymo Research) according to the manufacturer’s instructions. Escherichia coli ATCC 25922 and nutrient broth were used as positive and negative controls, respectively. DNA concentration and purity were assessed using an EzDrop 1,000 spectrophotometer. Libraries were sequenced on an Illumina MiSeq at the Agricultural Research Council–Biotechnology Platform (ARC-BTP). Raw reads were assembled and analysed using TORMES v1.3.0 at Biosyntiya Solutions. Taxonomic identification was confirmed using Kraken 2. Multilocus sequence typing (MLST) was performed using the relevant MLST databases. ARGs were identified by screening assembled genomes against ResFinder (version 4.0, January 2025) and the Comprehensive Antibiotic Resistance Database (CARD; version 4.0.1, January 2025) using thresholds of ≥90% identity and ≥80% coverage unless otherwise stated. Virulence factors were identified using the Virulence Factor Database [VFDB; version (2025), January 2025]; hits with <97% identity or <100% coverage were excluded. The datasets supporting WGS have been deposited in the NCBI SRA under BioProjects PRJNA1363166, PRJNA1364784, and PRJNA1363723.
Statistical analysis
Statistical analyses were based on campaign-level means calculated from triplicate measurements collected during June, August and October 2023. One-way ANOVA was used to compare influent, effluent, upstream and downstream sampling locations within each WWTP, while two-sided paired t-tests were used to compare WWTP1 and WWTP2 at matched sampling locations across the three sampling campaigns.
Results
Physicochemical parameters
Influent and effluent
The water quality assessed using in situ physicochemical parameters at the influent and effluent points of WWTP 1 and 2 during the sampling period is presented in Table 1. The measured pH at influent and effluent points for both plants ranged from 7.25 to 7.90. The temperature at WWTP 1 ranged from 15.60 °C to 20.33 °C, whereas at WWTP 2 it ranged from 19.34 °C to 22.33 °C. Overall, ANOVA analyse did not detect statistically significant differences in the measured physicochemical parameters between influent and effluent or between the two WWTPs (p = 0.05) (Supplementary Table A1). Total dissolved solids (TDS) in the influent and effluent of WWTP 1 ranged from 181 to 336 ppm, while those of WWTP 2 ranged from 175 to 365 ppm Table 1. The lowest TDS values at both plants were recorded during late autumn. TDS concentrations in the effluents of both plants were below the Department of Water Affairs and Forestry (DWAF) recommended discharge limit of 450 ppm. Dissolved oxygen (DO) levels measured in situ at WWTP 1 and WWTP 2 ranged from 24 to 125% (Table 1). The highest DO level was observed in the WWTP 2 effluent during late autumn, whereas the lowest level was recorded in the influent of WWTP 1 during winter.
Table 1
| Season | Sampling points | Physicochemical parameters influent vs effluent | ||||
|---|---|---|---|---|---|---|
| pH | Temp(°C) | DO (%) | TDS (ppm) | |||
| June | WWTP1 | Influent | 7.53 ± 0.015 | 15.60 ± 0.100 | 24.33 ± 0.578 | 336,33 ± 1.528 |
| Effluent | 7.37 ± 0.006 | 16.73 ± 0.578 | 26.77 ± 0.723 | 308.67 ± 2.517 | ||
| WWTP2 | Influent | 7.42 ± 0.020 | 20.42 ± 0.010 | 28.67 ± 0.577 | 365.33 ± 0.577 | |
| Effluent | 7.45 ± 0.006 | 19.27 ± 0.115 | 40.67 ± 1.527 | 231.33 ± 0.577 | ||
| August | WWTP1 | Influent | 7.31 ± 0.015 | 18.90 ± 0.100 | 27.00 ± 1.000 | 332.00 ± 1.000 |
| Effluent | 7.51 ± 0.015 | 18.40 ± 0.100 | 33.33 ± 3.055 | 326.00 ± 1.000 | ||
| WWTP2 | Influent | 7.50 ± 0.000 | 19.83 ± 0.058 | 27.67 ± 0.528 | 330.00 ± 1.000 | |
| Effluent | 7.25 ± 0.000 | 19.34 ± 0.494 | 41.67 ± 1.528 | 295.00 ± 1.000 | ||
| October | WWTP1 | Influent | 7.92 ± 0.015 | 22.30 ± 0.000 | 64.50 ± 0.500 | 181.33 ± 2.081 |
| Effluent | 7.35 ± 0.010 | 20.93 ± 0.058 | 114.4 ± 0.529 | 170.00 ± 0.000 | ||
| WWTP2 | Influent | 7.44 ± 0.006 | 21.97 ± 0.577 | 54.00 ± 1.000 | 175.33 ± 0.577 | |
| Effluent | 7.51 ± 0.010 | 22.33 ± 1.528 | 125.00 ± 1.000 | 181.00 ± 0.000 | ||
| Wastewater effluent (General limit, SA Act no. 36 of 1998) (Van der Merwe-Botha and Leonardo, 2011) | 5,5-9,5 | 35 | ≥75 | 25 ≥ | ||
In situ physicochemical parameters of influent vs. effluent wastewater samples from WWTP 1 and WWTP 2 in South Africa, measured seasonally (mean ±SE, n = 3).
Upstream and downstream
The physicochemical parameters measured in situ at the upstream and downstream river sites associated with WWTPs 1 and 2 are presented in Table 2. Water temperature ranged from 16.6 °C to 23.5 °C. The physicochemical characteristics of the wastewater and receiving-water samples varied among sampling locations and between the two wastewater treatment plants (WWTPs), although no statistically significant differences were detected after adjustment for multiple comparisons. The pH values ranged from 7.18 to 8.36 and generally fell within the South African Department of Water Affairs and Forestry (DWAF), South Africa (1996) (Table 2). Total dissolved solids (TDS) concentrations in the upstream and downstream rivers of both WWTPs ranged from 113 ppm to 330 ppm. Paired t-tests comparing the two WWTPs at matched sampling locations showed no statistically significant differences after Holm adjustment (Supplementary Table A2).
Table 2
| Seasons | Sampling points | Physicochemical parameters | |||
|---|---|---|---|---|---|
| pH | Temp(°C) | DO (%) | TDS (ppm) | ||
| Winter | WWTP 1-U | 7.46 ± 0.007 | 18.33 ± 0.231 | 37.33 ± 0.121 | 211.33 ± 0.577 |
| WWTP 1-D | 7.57 ± 0.012 | 17.20 ± 0.200 | 27.67 ± 1.058 | 194.00 ± 2.000 | |
| WWTP 2-U | 7.41 ± 0.015 | 16.30 ± 0.100 | 48.66 ± 0.577 | 156.00 ± 2.000 | |
| WWTP 2-D | 7.58 ± 0.010 | 19.47 ± 0.115 | 28.00 ± 1.000 | 230.33 ± 0.577 | |
| Autum | WWTP 1-U | 7.56 ± 0.025 | 18.50 ± 0.100 | 36.33 ± 1.528 | 261.67 ± 0.578 |
| WWTP 1-D | 7.68 ± 0.020 | 19.53 ± 0.058 | 26.00 ± 1,000 | 176.67 ± 1.528 | |
| WWTP 2-U | 7.95 ± 0.015 | 16.99 ± 0.015 | 39.33 ± 0.577 | 171.67 ± 0.578 | |
| WWTP 2-D | 8.59 ± 1.166 | 19.60 ± 0.100 | 30.00 ± 1.000 | 305.33 ± 0.577 | |
| Late autumn | WWTP1-U | 7.63 ± 0.006 | 23.50 ± 0.000 | 109.33 ± 3.786 | 132.67 ± 1.155 |
| WWTP1-D | 7.33 ± 0.015 | 19.93 ± 0.058 | 78,00 ± 1.000 | 132.33 ± 0.577 | |
| WWTP 2-U | 7.23 ± 0.010 | 19.20 ± 0.000 | 97.33 ± 1.528 | 117.67 ± 0.577 | |
| WWTP 2-D | 7.82 ± 0.577 | 16.67 ± 0.578 | 1.25.00 ± 0.004 | 102.33 ± 0.577 | |
| DWA irrigation standards (1996)(Department of Water Affairs and Forestry (DWAF), South Africa) | 6.5–8.4 | ≤ 30\u00B0C° | 80% | 1,100 | |
In situ Physicochemical parameters of upstream and downstream river samples from WWTP 1 and WWTP 2 in South Africa, measured seasonally (mean ±SE, n = 3).
Isolation and quantification of bacteria
Presumptive Enterococcus and Staphylococcus species were successfully isolated and identified from water samples using chromogenic media. Presumptive Enterococcus colonies appeared pink to red on Enterococcus selective agar, while and S. aureus colonies appeared yellow on mannitol salt phenol red agar (Supplementary Appendix S1 A–C). After Gram staining, the bacteria were identified as coccus-shaped and Gram-positive (Supplementary Appendix S1 D,E). The targeted bacteria were detected at all sampling sites (Figure 2). The results show that WWTP1 had consistently higher bacterial concentrations compared with WWTP2 (Figure 2). In addition, the concentration of presumptive Enterococcus bacteria were higher than that Staphylococcus bacteria of in both WWTPs. Notably, high bacterial concentrations were observed in WWTP 1 effluents during all sampling periods. Overall, the removal efficiency of bacteria by WWTP2 at effluent across seasons was higher compared to WWTP1 (Supplementary Table A3.1).
Figure 2
Profiling of antibiotic resistance
The antibiotic resistance profiles of 54 presumptive Enterococcus faecium and Staphylococcus aureus isolates were evaluated against nine antibiotics in duplicate across three sampling seasons (Table 3). All E. faecium isolates exhibited the highest resistance to tetracycline across all seasons, while the highest resistance to linezolid (18.5%) was observed during winter. A previous study conducted in South African private hospitals between 2016 and 2018 reported high antibiotic resistance in E. faecium against penicillin/ampicillin (92%), teicoplanin (4%), and vancomycin (4%). The Staphylococcus isolates showed the highest resistance to tetracycline (30.8%), clarithromycin (16.7%), and azithromycin (12.3%). Overall, the study demonstrated the presence of ARB isolates from different WWTP, and associated rivers exhibited varying antibiotic resistance patterns.
Table 3
| Antibiotics | Bacteria | Number of isolates (%) winter | Number of isolates (%) autumn | Number of isolates (%) late autumn | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| S | I | R | S | I | R | S | I | R | ||
| Ampicillin (10 μg) | EF | 52(96.3) | 0(00.0) | 2(03.7) | 51(94.4) | 0(00.0) | 3(5.6) | 50(92.6) | 0(00.0) | 4(7.4) |
| SP | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | |
| Azithromycin (30 μg) | SP | 38(70.4) | 10(18.5) | 6(11.1) | 52(96.3) | 0(00.0) | 2(03.7) | 38(70.4) | 4(07.4) | 12(22.2) |
| Cefoxitin (30 μg) | SP | 52(96.3) | 0(00.0) | 2(03.7) | 40(74.1) | 0(00.0) | 14(25.9) | 54(100) | 0(00.0) | 0(00.0) |
| Clarithromycin (15 μg) | SP | 48 (88.9) | 0(00.0) | 6(11.1) | 54(100) | 0(00.0) | 0(00.0) | 38(70.4) | 4(7.4) | 12(22.2) |
| Chloramphenicol (10 μg) | EF | 52(96.3) | 2(03.7) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 50(92.6) | 0 (00.0) | 4(07.4) |
| SP | 50(92.5) | 4(7.4) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | |
| Linezolid (30 μg) | EF | 43(79.6) | 6(11.1) | 5(9.3) | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) |
| SP | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | |
| Teicoplanin (30 μg) | EF | 53(98.1) | 1(1.9) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 51(94.4) | 0(00.0) | 3(5.6) |
| Tetracycline (30 μg) | EF | 38 (72.2) | 0(00.0) | 15(27.3) | 26(66.6) | 3(5.5) | 15(27.58) | 42(77.7) | 0(00.0) | 12(22.2) |
| SP | 48 (88.9) | 6(11.1) | 0(00.0) | 9(33.3) | 9(33.3) | 9(33.3) | 38(70.4) | 2(3.7) | 14(25.9) | |
| Vancomycin (30 μg) | EF | 49 (90.7) | 5(9.3) | 0(00.0) | 53(98.1) | 1(1.9) | 0(00.0) | 49(90.7) | 2(3.7) | 3(5.6) |
| SP | 54 (100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | 54(100) | 0(00.0) | 0(00.0) | |
Total antibiotic resistance profile of E. faecium and Staphylococcus species bacteria isolated from water samples (each n = 54).
Antibiotic susceptibility testing results: S = susceptible, I = intermediate and R = resistance. Presumptive bacteria: EF = Enterococcus faecium and SP = Staphylococcus aureus.
Multiple antibiotic resistance index analysis
The shows that the multiple antibiotic resistance index (MARI) values ranged from 0.13 to 0.71 (Figure 3). The highest MARI value (0.71) was observed among presumptive Enterococcus isolates from the upstream river at WWTP 1, indicating a high-risk source of contamination upstream of the treatment plant. A presumptive Enterococcus isolate from the WWTP 1 influent also exhibited a relatively high MARI value of 0.43. Overall, MARI values were higher at WWTP 1 than at WWTP 2. The detection of multidrug-resistant (MDR) bacteria in the upstream river water suggests pre-existing environmental contamination of the river. Presumptive S aureus isolates showed lower levels of antibiotic resistance than Enterococcus species, with MARI values ranging from 0.13 to 0.25, whereas Enterococcus isolates exhibited MARI values ranging from 0.29 to 0.71 (Figure 3). In this study, only two presumptive S. aureus isolates were resistant to cefoxitin, indicating possible methicillin resistance in these strains.
Figure 3
Whole-genome sequencing
The quality assessment results for the raw sequencing reads and genome assemblies generated after WGS are summarized in Table 4. The number of sequencings reads per sample ranged from 13,516,996 to 27,481,988. Across all isolates, the number of contigs per genome ranged from 777 to 2,631. The average genome sizes of the isolates ranged from 2,937,054 bp to 6,072,351 bp, with E. faecium isolates exhibiting the largest genomes. Although this assembly had high sequencing depth (587x), its relatively large genome size and fragmentation should be interpretation but, in this study, taxonomic classification of isolates were confirmed with Kraken 2. The N50 values for all assemblies exceeded 10,000 bp, indicating acceptable assembly continuity. The GC content of E. faecium isolates ranged from 38.32 to 40.42%, whereas the GC content of Staphylococcus isolates ranged from 33.47 to 35.79%, consistent with the reported GC content ranges for these genera. The sequencing depth for all samples exceeded 101X, which is within recommended thresholds for robust comparative genomics. The genome sizes and contig numbers varied considerably within species, which is likely related to differences in chromosome size and the presence or absence of plasmids among isolates. Overall, the observed read lengths, contig lengths, N50 values, and sequencing depth indicate that WGS was successful. Taxonomic classification based on the assembled genomes confirmed that the isolates were E. faecium and S. aureus.
Table 4
| Samples | Reads | Contigs | Ave genome length (bp) | Largest contig (bp) | N50 | GC (%) | Depth |
|---|---|---|---|---|---|---|---|
| E faecium 1 | 23,941,566 | 2,194 | 6,072,351 | 304,001 | 15,035 | 38.32 | 587X |
| E faecium 2 | 13,516,896 | 777 | 2,970,240 | 371,412 | 82,977 | 38.28 | 678X |
| E faecium 3 | 25,232,038 | 1,172 | 2,996,560 | 526,193 | 131,917 | 39.04 | 1,254X |
| E faecium 4 | 32,626,118 | 1,579 | 3,136,761 | 227,155 | 98,584 | 39.1 | 1,549X |
| E faecium 5 | 19,275,206 | 2,392 | 3,245,903 | 229,323 | 85,163 | 40.42 | 884X |
| S. aureus 1 | 18,778,214 | 659 | 2,937,054 | 523,509 | 151,611 | 33.47 | 952X |
Whole-genome sequencing assembly statistics generated using TORMES.
Multi-locus sequence typing
The four E. faecium isolates recovered from locations at two WWTPs displayed distinct sequence types (ST), namely ST1052, ST1058, ST94, and ST32 (Table 5). However, E. faecium 1 could not be assigned to a recognised ST because of missing alleles. The S aureus isolate from upstream site of WWTP 1 was assigned to ST243.
Table 5
| Bacteria | Multi-locus sequence typing | ST | ||||||
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | ||
| EF1 | AtpA (15) | ddl (3) | gdh (1) | purK (14) | gyd (1) | pstS (1) | adk (1) | |
| EF2 | atpA (13) | ddl (8) | gdh (52) | purK (22) | gyd (6) | pstS (27) | adk (6) | 1,052 |
| EF3 | atpA (2) | ddl (76) | gdh (2) | purK (2) | gyd (1) | pstS (1) | adk (1) | 1,058 |
| EF4 | atpA (13) | ddl (8) | gdh (8) | purK (8) | gyd (6) | pstS (10) | adk (6) | 94 |
| EF5 | atpA (3) | ddl (3) | gdh (1) | purK (2) | gyd (1) | pstS (1) | adk (1) | 32 |
| SA | arcC (2) | aroE (2) | glpF (5) | gmk (2) | pta (6) | tpi (3) | yqiL (2) | 243 |
Multilocus sequencing typing was used to differentiate the levels of bacterial strains.
Antibiotic resistance genes
The results showed that all five E. faecium isolates and the S. aureus isolate carried multidrug-resistance genes following genome screening using the ResFinder and CARD databases (Figure 4). ResFinder did not detect any ARGs in S. aureus; however, ARGs were identified when the CARD database was used, highlighting differences in detection sensitivity between the databases. Tetracycline-resistance genes were the most frequently detected ARGs among the isolates, except in E. faecium 2. Each E. faecium isolate harboured either the tetL or tetM gene, which are commonly associated with mobile genetic elements. In addition, several multidrug-resistance genes were identified in the E. faecium isolates, including msr(C), ermB18, and lsaA_1, conferring resistance to multiple antibiotic classes such as macrolides, lincosamides, streptogramins, and pleuromutilins.
Figure 4
Among the isolates, E. faecium 1 from WWTP 1 carried the highest number of ARGs, including dfrE and dfrG (diaminopyrimidine resistance), Erb (lincosamide, macrolide, and streptogramin resistance), and lsa genes associated with resistance to aminoamides, macrolides, oxazolidinones, phenicols, pleuromutilins, streptogramins, and tetracyclines. Multiple resistance mechanisms, including Ema, msrC, ErmB, and lsa, were also detected in these isolates. Furthermore, the CARD database identified several ARGs in S. aureus 1, including ArlS and ArlR (fluoroquinolone resistance), FosB (fosfomycin resistance), MapA and MepR (tetracycline resistance), NorA (fluoroquinolone resistance), and NorR, which confers resistance to cephalosporins, fluoroquinolones, penams, peptides, and tetracyclines. Overall, most detected ARGs were associated with multidrug resistance, posing a significant public health concern and complicating efforts to combat antimicrobial resistance.
Virulence factor genes
The five E. faecium isolates and S. aureus haboured a range of virulence factor genes (Figure 5). Most virulence genes were found in the S. aureus isolate (55 genes), followed by E. faecium 1 (24 genes), while E. faecium 2–5 each carried a single. The full description of the virulence factor genes is provided in Supplementary Table A4. The E. faecium isolates carried several virulence genes, including those associated with surface adhesion (Acm, SgrA,srtC, and Fsl), biofilm genes (ebpB), capsule formation (CapsA and CapsK), and toxins (cylA,cylB,cylI,cylL,cylR1,cylR2, and cylS), particularly in E. faecium 1. E. faecium 1 from WWTP1 exhibited the highest numbers of both ARGs and virulence genes, suggesting that this strain could represent a potential pathogen. Similarly, the S. aureus isolate from WWTP1 carried a diverse array of virulence genes contributing to pathogenicity, including adhesion genes (Clf, EbP, icaA–icaC, srtB), toxin genes (HlB, HlD, HlgA–HlgC, Hly/Hla, lukF-PV, lukS-PV), enzyme genes (AdsA, Cap8A–CapP, GeH, HysA, lip, scpA–scpC), host immune invasion genes (EsaA, EsaB, Sbi, and SpA), and iron acquisition genes (isdA–isdG). The S. aureus isolate also encoded hla (alpha-haemolysin) and hld (delta-haemolysin), both implicated in skin and soft tissue infections.
Figure 5
Discussion
E. faecium and S. aureus isolates recovered from the two Johannesburg, South African WWTP associated environments harboured multiple ARGs, and virulence associated genes, indicating their potential to persist in and contribute to AR om aquatic environments. Wastewater treatment plants are important hotspots for the emergence and dissemination of ARB and ARGs into the environment (Guo et al., 2017; Pazda et al., 2019). In the present study, WWTP1 showed lower bacterial removal WWTP2 and result high bacterial concentrations in its final effluent. This suggests that WWTP1 contribute to the downstream river water contamination of ARB. However, this study has not established WWTP1 as principal or sole source of ARB in the receiving river, since ARB were also detected at the upstream river and genomic analysis in study smaller sample size, only six isolates. In this study evaluated physicochemical parameters for assessing water quality (water temperature, pH, DO, and TDS) in both WWTPs complied with the recommended DWAF limits and showed no significant variation across the sampling sites (Supplementary Table A1). The physiochemical parameters in wastewater are collectively important operational parameters that influence the survival, persistence, spread of ARB and ARGs into receiving rivers (Muoghalu et al., 2025). The water temperature and TDS measured in the two WWTPs were lower than those reported by Olabode et al. for wastewater effluent in Cape Town, South Africa, where values ranged from (19.0–36 °C) and (590.72–828.27 ppm), respectively (Olabode et al., 2020). Water temperature is known to potentially influence bacterial growth, metabolic activity, and the horizontal transfer of ARGs (Li et al., 2024), while the water pH affects antibiotic pollutants stability and bacterial survival in water (Kulik et al., 2023; Razmi et al., 2023). Dissolved oxygen also plays a role in microbial activity and resistance gene expression as different bacterial species adapt to different level of oxygens (Qin et al., 2023; Wu et al., 2024). Collectively, DO and TDS results suggested that WWTP 2 performed better than WWTP 1, indicating improved treatment efficiency and effluent quality. Variations in influent sources and operational design between the two WWTPs such as the presence of maturation pond in WWTP2 may have contributed to efficiency of WWP2 compared to WWTP1. Overall, WWTP effluent physicochemical conditions, including water temperature, pH, DO and TDS, together with nutrients and chloride which are not measured in study, exert selective pressure that can promote the spread of ARB and ARGs into rivers.
WWTP2 reduced Enterococcus and Staphylococcus bacteria loads more effectively compared to WWTP1 (Supplementary Table A3.1 and Table A3.2). Microbial count in this study showed that E. faecium and S. aureus counts in the final effluent of WWTP 1 exceeded 1,000 CFU/mL across all seasons (Figure 2). Difference in bacterial reduction between the two WWTPs may be explained by presence of a maturation pond in WWTP2, which reduces bacteria at WWTP effluent contributing to its better performances relative to WWTP1. Persistently high bacterial in WWTP1 effluent indicate possible disinfection inefficiencies, although chloride was not measured to confirm this claim. High bacterial counts measured in the Klipspruit River likely reflect local be illegal dumping and sewage contamination within the catchment area, while elevated bacterial counts downstream river of WWTP1 are likely associated with the discharge of inadequately treated effluent of WWTP1. These findings are consistent with the 2023 Green Drop report, which highlighted that many South African WWTPs are ageing and frequently release partially treated effluent into rivers (Department of Water and Sanitation, 2023). Consequently, the discharge of inadequately treated wastewater poses significant health risks to humans, animals, and the environment.
Antibiotic resistance profiles differed between Staphylococcus and Enterococcus isolates from the two WWTPs (Table 3). Differences in antibiotic resistance profiles observed in this study may be attributed to variations in antibiotic pollutants, ARB, and ARGs exposure wastewater. Staphylococcus isolates in this study showed lower AR profile than reported in some previous South African studies and were fully susceptible to ampicillin and vancomycin (Qin et al., 2023; Ramessar and Olaniran, 2019). In contrast, Enterococcus isolates exhibited resistance mainly to azithromycin and tetracycline (Table 3, Figure 3). Although only a few MDR isolates were recovered from effluent samples, WWTP 1 is potential source of ARB release into receiving rivers, given its comparatively lower bacterial removal efficiency. The presence of ARB upstream suggests that WWTP associated discharge is not the only possible source of resistance in the river. Therefore, the finding support continued surveillance and optimisation of wastewater disinfection and potentially suggesting that conventional activated sludge treatment in WWTP1 is not effectively eliminate ARB compared WWTP2. Therefore, continuous surveillance and optimisation of WWTP disinfection processes are necessary to reduce the spread of antibiotic resistance and its associated environmental and public health risks.
Whole genome sequencing of selected MDR isolates identified clinically relevant sequence types and a diversity of ARGs and virulence factors. Six MDR isolates (five presumptive E. faecium and one presumptive S. aureus) were sequenced (Table 4). E. faecium sequence types ST32, ST94, ST1052, and ST1058 were detected, ST32 and ST94 have been reported in pigs and goats from Ghana and associated with resistance to erythromycin, ciprofloxacin, and tetracycline (Amuasi et al., 2023). In contrast, limited information is available for ST1052 and ST1058, indicating that these may represent rare or underreported lineages in South Africa. The S. aureus isolate was ST243, previously identified in dairy cows in the Free State Province of South Africa and associated with multidrug resistance to macrolides and tetracyclines (Khasapane et al., 2024). The occurrence of these clinically relevant sequence types in river water highlights the role of aquatic environments as potential reservoirs and dissemination pathways for antimicrobial-resistant bacteria.
Tetracycline-resistance genes tetL and tetM, were among the most common ARGs detected, and virulence profiling identified genes involved in adhesion, invasion, toxin production, immune modulation and biofilm formation (Figures 4, 5). The identification of multiple ARGs in the present study is also comparable to findings reported by Rahim et al. (2024), who detected diverse resistance determinants in bacteria isolated from wastewater and receiving waters, including tetracycline, sulfonamide, aminoglycoside and β-lactam resistance genes (Rahim et al., 2024). Together, these findings demonstrate the value of combining phenotypic antimicrobial susceptibility testing with molecular or genomic approaches to characterise environmental AMR. Smith and colleagues conducted a 24-month metagenomic investigation of raw sewage from four wastewater-treatment works in Tshwane and Ekurhuleni, Gauteng, South Africa. They found that aminoglycoside, beta-lactam, sulfonamide and tetracycline resistance were the dominant resistance classes. The sul1 gene was the most abundant resistance gene, while resistance profiles differed between municipalities, treatment plants and socioeconomic settings (Smith et al., 2024).
The phenotypic resistance to azithromycin observed in E. faecium was supported by the presence of the ermB gene in the corresponding sequenced isolates. However, not all observed phenotypic resistance profiles were consistent with the ARGs identified using the ResFinder and CARD database. Such discrepancies may arise from gene regulation and expression, mutation or alternative resistance mechanism, database limitations, and stringent CARD cut-off thresholds that can increase false-positive detections and overestimate resistance (Manzoor et al., 2025). Importantly, detection of an ARG does not indicate phenotypic expression and thus phenotypic and genotypic relationship should therefore be interpreted with caution. Differences between phenotypic and genotypic resistance may also arise from false-positive or false-negative results, reduced gene expression, or low ARG copy numbers. Furthermore, the absence of known ARGs despite phenotypic resistance may indicate the presence of novel resistance mechanisms. Although WGS provides an opportunity to investigate genomic context, the present study did not perform a dedicated analysis of ARG localization. Consequently, the chromosomal or mobile-element location of tetL, tetM, ermB and other detected ARGs could not be established, and their potential for horizontal transfer remains to be determined. VFDB analysis identified multiple virulence factors in both E. faecium and S. aureus isolates, with S. aureus carrying highest number of virulence genes 55 genes, followed by E. faecium 1 (Figure 5). E. faecium carried cylA, which has previously been associated with human infections (Ferguson et al., 2016). S. aureus isolate harboured the LukS/F-PV gene, a cytotoxin associated with leukocyte destruction and tissue necrosis (Wilson et al., 2023). These findings highlight the importance of continuous surveillance of ARB, ARGs and virulence factors for public health and environmental safety.
This study was limited by the three sampling campaigns, culture-dependent bacterial detection, and the small number of isolates subjected to WGS. Only six MDR isolates were sequenced, limiting the generalisation of the genomic findings. Genotype–phenotype differences were observed, while the genomic location and mobility of ARGs were not determined. In addition, the detection of resistant bacteria upstream means that WWTPs cannot be confirmed as the sole source of downstream AMR. These limitations should be considered when interpreting the findings and highlight the need for longer-term sampling and broader genomic analyses. Future studies should comprehensively assess AR in WWTPs by screening both ARB, which carry intracellular ARGs, and free-floating ARGs present in water (extracellular ARGs). This approach will provide a more comprehensive understanding of the total antibiotic resistance crisis. This will improve detection of ARG dissemination and support better monitoring of the spread of antimicrobial resistance in South African wastewater systems. Future studies should include longitudinal sampling, more WGS isolates, and metagenomic approaches. Genomic analyses should investigate the mobility and potential horizontal transfer of ARGs, while source-tracking approaches could help distinguish pre-existing river contamination from WWTP-associated contributions. These approaches will improve understanding of AMR persistence and dissemination in South African aquatic systems.
Conclusion
This study demonstrated the occurrence of Enterococcus and Staphylococcus spp., antimicrobial resistance, and ARGs in two WWTPs and their receiving rivers in Johannesburg. WWTP2 showed greater bacterial reduction than WWTP1, while WWTP1 appeared to be a potential contributor to the downstream burden of antimicrobial-resistant bacteria. WGS further identified diverse ARGs and virulence-associated determinants among selected MDR isolates, although their genomic mobility and source could not be definitively established. These findings highlight the importance of routine monitoring of wastewater effluents and receiving rivers to support early detection and management of environmental AMR in South Africa.
Statements
Data availability statement
The data supporting the findings of this study are available from the corresponding author upon reasonable request. The datasets supporting WGS have been deposited in the NCBI SRA under BioProjects PRJNA1363166, PRJNA1364784, and PRJNA1363723.
Author contributions
NM: Writing – original draft, Formal analysis, Visualization, Conceptualization, Data curation, Investigation, Methodology. TMs: Writing – review & editing, Conceptualization, Supervision. TMa: Supervision, Writing – review & editing, Conceptualization. KC: Writing – review & editing. IK: Writing – review & editing, Supervision, Conceptualization, Project administration, Validation.
Funding
The author(s) declared that financial support was received for this work and/or its publication. The authors thank the Institute for Nanotechnology and Water Sustainability (iNanoWS) of the University of South Africa for providing the facilities used in this study and funding the project.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that Generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/frwa.2026.1955602/full#supplementary-material
References
1
AlamM.FerdousS.ErcumenA.LinA.KamalA.LuiesS. K.et al. (2021). Effective treatment strategies for the removal of antibiotic-resistant bacteria, antibiotic-resistance genes, and antibiotic residues in the effluent from wastewater treatment plants receiving municipal, hospital, and domestic wastewater: protocol for a systematic review. JMIR Res. Protoc.10:e33365. doi: 10.2196/33365,
2
AmuasiG. R.DsaniE.Owusu-NyantakyiC.OwusuF. A.MohktarQ.NilssonP.et al. (2023). Enterococcus species: insights into antimicrobial resistance and whole-genome features of isolates recovered from livestock and raw meat in Ghana. Front. Microbiol.14:1254896. doi: 10.3389/fmicb.2023.1254896
3
BrownC. L.Maile-MoskowitzA.LopatkinA. J.XiaK.LoganL. K.DavisB. C.et al. (2024). Selection and horizontal gene transfer underlie microdiversity-level heterogeneity in resistance gene fate during wastewater treatment. Nat. Commun.15:5412. doi: 10.1038/s41467-024-49742-8,
4
Department of Water Affairs and Forestry (DWAF). (1996). South African Water Quality Guidelines. Vol. 4: Agricultural Water Use – Irrigation. (2nd ed.). South Africa: Department of Water Affairs and Forestry, Pretoria.
5
Department of Water and Sanitation (2023). Green drop watch report. Available online at: https://ws.dws.gov.za/iris/releases/GDWR.pdf (Accessed July 23, 2026).
6
du PlessisE. M.RichterL.KorstenL. (2024). An independent investigation and advisory on the role of water, sanitation and hygiene in the 2023 Cholera outbreak in HAMMANSKRAAL, South Africa. Available online at: https://www.wrc.org.za/wp-content/uploads/mdocs/3167-5%20final.pdf (Accessed July 23, 2026).
7
FergusonD. M.TalaveraG. N.HernándezL. A. R.WeisbergS. B.AmbroseR. F.JayJ. A. (2016). Virulence genes among Enterococcus faecalis and Enterococcus faecium isolated from coastal beaches and human and nonhuman sources in Southern California and Puerto Rico. J. Pathog.2016:3437214. doi: 10.1155/2016/3437214
8
FriedmanN. D.TemkinE.CarmeliY. (2016). The negative impact of antibiotic resistance. Clin. Microbiol. Infect.22, 416–422. doi: 10.1016/j.cmi.2015.12.002,
9
GholizadehA.KhiadaniM.ForoughiM.Alizade SiukiH.MehrfarH. (2023). Wastewater treatment plants: the missing link in global one-health surveillance and management of antibiotic resistance. J. Infect. Public Health16, 217–224. doi: 10.1016/j.jiph.2023.09.017,
10
GuoJ.LiJ.ChenH.BondP. L.YuanZ. (2017). Metagenomic analysis reveals wastewater treatment plants as hotspots of antibiotic resistance genes and mobile genetic elements. Water Res.123, 468–478. doi: 10.1016/j.watres.2017.07.002,
11
JackU.de SouzaP.MoorgasS. (2016). Guidelines on using the Wastewater Treatment Technologies Selection Decision Support Tool (W2DST). Tshwane: Water Research Commission.
12
JampaniM.ChandyS. J. (2021). Increased antimicrobial use during COVID-19: the risk of advancing the threat of antimicrobial resistance. Health Sci. Rep.4:e459. doi: 10.1002/hsr2.459,
13
KhasapaneN. G.NkhebenyaneJ.MnisiZ.KwendaS.ThekisoeO. (2024). Comprehensive whole genome analysis of Staphylococcus aureus isolates from dairy cows with subclinical mastitis. Front. Microbiol.15:1376620. doi: 10.3389/fmicb.2024.1376620
14
KorzeniewskaE.HarniszM. (2018). Relationship between modification of activated sludge wastewater treatment and changes in antibiotic resistance of bacteria. Sci. Total Environ.639, 304–315. doi: 10.1016/j.scitotenv.2018.05.165,
15
KulikK.Lenart-BorońA.WyrzykowskaK. (2023). Impact of antibiotic pollution on the bacterial population within surface water with special focus on mountain Rivers. Water15:975. doi: 10.3390/w15050975,
16
La RosaM. C.MaugeriA.FavaraG.La MastraC.Magnano San LioR.BarchittaM. (2025). The impact of wastewater on antimicrobial resistance: a scoping review of transmission pathways and contributing factors. Antibiotics (Basel, Switzerland)14:131. doi: 10.3390/antibiotics14020131
17
LiY.ZhengQ.LuY.QiaoY.GuoH.MaQ.et al. (2024). Water temperature disturbance alters the conjugate transfer of antibiotic resistance genes via affecting ROS content and intercellular aggregation. J. Hazard. Mater.479:135762. doi: 10.1016/j.jhazmat.2024.135762,
18
MahoneyA. R.SafaeeM. M.WuestW. M.FurstA. L. (2021). The silent pandemic: emergent antibiotic resistances following the global response to SARS-CoV-2. IScience24:102304. doi: 10.1016/j.isci.2021.102304,
19
ManzoorH.LiH.KayaniM. (2025). Identification of antibiotic resistance genes from whole genome and metagenome sequencing datasets. One Health Adv.3:4280. doi: 10.1186/s44280-025-00079-x
20
MokhonoanaN. K.MalefetseT. J.MsagatiT. A. M.KamikaI. (2026). Antibiotic pollutants and resistance in Escherichia coli and Bacillus cereus from South African wastewater treatment plants. J. Environ. Manag.409:130001. doi: 10.1016/j.jenvman.2026.130001,
21
MuoghaluC.KaboggozaH. C.SemiyagaS.LebuS.LiuC.NiwagabaC.et al. (2025). Antibiotic resistant bacteria (ARB) and genes (ARGs) in urban wastewater treatment plants: influencing factors, mechanisms, and removal efficiency. Environ. Pollut.383:126851. doi: 10.1016/j.envpol.2025.126851,
22
OlabodeG. S.OlorundareO. F.SomersetV. S. (2020). Physicochemical properties of wastewater effluent from two selected wastewater treatment plants (Cape Town) for water quality improvement. Int. J. Environ. Sci. Technol.17, 4745–4758. doi: 10.1007/s13762-020-02788-9
23
OlanrewajuO. S. S.BezuidenhoutC. C. C. (2025). Harnessing beneficial bacteria to remediate antibiotic-polluted agricultural soils: integrating source diversity, bioavailability modulators, and ecological impacts. Front. Microbiol.16:1635233. doi: 10.3389/fmicb.2025.1635233
24
PazdaM.KumirskaJ.StepnowskiP.MulkiewiczE. (2019). Antibiotic resistance genes identified in wastewater treatment plant systems – a review. Sci. Total Environ.697:134023. doi: 10.1016/j.scitotenv.2019.134023,
25
PolianciucS. I.GurzăuA. E.KissB.ŞtefanM. G.LoghinF. (2020). Antibiotics in the environment: causes and consequences. Med. Pharmacy Reports93, 231–240. doi: 10.15386/mpr-1742,
26
QinL.WangD.ZhangZ.LiX.ChaiG.LinY.et al. (2023). Impact of dissolved oxygen on the performance and microbial dynamics in side-stream activated sludge hydrolysis process. Water15:977. doi: 10.3390/w15111977
27
RahimK.NawazM. N.AlmehmadiM.AlsuwatM. A.LiuL.YuC.et al. (2024). Public health implications of antibiotic resistance in sewage water: an epidemiological perspective. Bioresour. Bioprocess.11:91. doi: 10.1186/s40643-024-00807-y,
28
RamessarK.OlaniranA. O. (2019). Antibiogram and molecular characterization of methicillin-resistant Staphylococcus aureus recovered from treated wastewater effluent and receiving surface water in Durban, South Africa. World J. Microbiol. Biotechnol.35:142. doi: 10.1007/s11274-019-2715-9,
29
RazmiN.LazouskayaM.PajcinI.PetrovicB.GrahovacJ.SimicM.et al. (2023). Monitoring the effect of pH on the growth of pathogenic bacteria using electrical impedance spectroscopy. Results Eng.20:101425. doi: 10.1016/j.rineng.2023.101425
30
SalamM. A.Al-AminM.SalamM. T.PawarJ. S.AkhterN.RabaanA. A.et al. (2023). Antimicrobial resistance: a growing serious threat for global public health. Healthcare (Basel, Switzerland)11:1946. doi: 10.3390/healthcare11131946,
31
SambazaS. S.NaickerN. (2023). Contribution of wastewater to antimicrobial resistance: a review article. J. Glob. Antimicrob. Resist.34, 23–29. doi: 10.1016/j.jgar.2023.05.010,
32
SmithA. M.RamudzuluM.MunkP.AvotB. J.EsterhuyseK. C.Van BlerkN.et al. (2024). Metagenomics analysis of sewage for surveillance of antimicrobial resistance in South Africa. PLoS One19:e0309409. doi: 10.1371/journal.pone.0309409
33
TuckerK.StoneW.BotesM.FeilE. J.WolfaardtG. M. (2022). Wastewater treatment works: a last line of defense for preventing antibiotic resistance entry into the environment. Front. Water4:883282. doi: 10.3389/frwa.2022.883282
34
Van der Merwe-BothaM.LeonardoM. (2011). Wastewater risk Abatement plan: a W₂RAP Guideline to plan and Manage towards safe and Complying Municipal Wastewater Collection and Treatment in South Africa. Water Research Commission. Available online at: https://www.wrc.org.za/wp-content/uploads/mdocs/TT%20489-11.pdf (Accessed July 23, 2026).
35
WilsonT. K.ZishiriO. T.El ZowalatyM. E. (2023). Molecular detection of virulence genes in Staphylococcus aureus isolated from wild pigeons (Columba domestica livia) in KwaZulu-Natal in South Africa. One Health (Amsterdam, Netherlands)18:100656. doi: 10.1016/j.onehlt.2023.100656
36
World Health Organization (2025). Global Antibiotic Resistance Surveillance Report 2025: WHO Global Antimicrobial Resistance and use Surveillance system (glass). Geneva: World Health Organization.
37
WuH.XingZ.ZhanG. (2024). Dissolved oxygen drives heterotrophic microorganism succession to regulate low carbon source wastewater treatment enhanced by slurry. J. Environ. Manag.366:121804. doi: 10.1016/j.jenvman.2024.121804,
Summary
Keywords
Enterococcus faecium, multidrug resistance bacteria, South Africa, Staphylococcus aureus, wastewater treatment plants, whole-genome sequencing
Citation
Mokhonoana NK, Msagati TAM, Malefetse TJ, Chokoe K and Kamika I (2026) Antibiotic resistance in South African wastewater: a snapshot from two treatment plants and their receiving rivers. Front. Water 8:1955602. doi: 10.3389/frwa.2026.1955602
Received
01 August 2026
Revised
27 September 2026
Accepted
30 September 2026
Published
19 October 2026
Volume
8 - 2026
Edited by
Mrunmayee Manjari Sahoo, Lovely Professional University, India
Reviewed by
Kevin Vu, University of Notre Dame, United States
Shahin Shah Khan, Beijing University of Chemical Technology, China
Updates
Copyright
© 2026 Mokhonoana, Msagati, Malefetse, Chokoe and Kamika.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ilunga Kamika, kamiki@unisa.ac.za
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.