Editorial: Methods in structural biology: Cryo-electron microscopy

by SPA is tenfold higher than that measured by MicroED. The authors also proposed the strategies to collecting high-resolution data using SPA and MicroED. Cryo-EM specimen preparation is the current bottleneck that impeding the broader use of cryo-EM technique. Many groups have been working hard to improve the sample preparation. Common issues with the process of vitrification are the poor/nonuniform distribution of protein molecules (particles), preferred orientation, protein denaturation/degradation at the water-air interface, high background noise from thick ice, etc. One of the techniques developed to improve the cryo-EM specimen preparation is to use the support films made of graphene and its derivatives. Fan and Sun have given a great review about the various advantages of graphene grid over conventional holey carbon film grids, functionalization of graphene support films, how to make the graphene grids, as well as the origins of pristine graphene contamination [Developing graphene grids for cryoelectron microscopy].Conformational heterogeneity of a biological molecule is a prerequisite for the molecule to perform its functions. In cryo-EM, the specimen heterogeneity not only presents the challenge for obtaining high-resolution structure, but also provides the opportunity to determine multiple structures of the same molecule/complexes with different conformations from same dataset, and thus the opportunity to investigate the conformational changes associated with its biological functions. Hybrid electron microscopy normal mode analysis (HEMNMA) was first developed in 2014 [Jin, et al., 2014] for analyzing continuous and large-scale conformational changes in cryo-EM, determines the conformation, orientation, and position of the complex in each single particle image with combined method of image analysis used in SPA and normal modes analysis (NMA) (the motion directions simulated for a given atomic structure or EM map), which in turn allows the determining the full conformational space of the complex but at the price of high

3,469 views

1 citations

Electron radiation damage to macromolecules is an inevitable resolution limit factor in all major structural determination applications using cryo-electron microscopy (cryo-EM). Single particle analysis (SPA) and micro-crystal electron diffraction (MicroED) have been employed to assess radiation damage with a variety of protein complexes. Although radiation induced sidechain density loss and resolution decay were observed by both methods, the minimum dose of electron irradiation reducing high-resolution limit reported by SPA is ten folds higher than measured by MicroED using the conventional dose concept. We compared and analyzed these two approaches side-by-side in detail from several aspects to identify some crucial determinants and to explain this discrepancy. Probability of a high energy electron being inelastically scattered by a macromolecule is proportional to number of layers of the molecules in its transmission path. As a result, the same electron dose could induce much more site-specific damage to macromolecules in 3D protein crystal than single particle sample. Major differences in data collection and processing scheme are the key factors to different levels of sensitivity to radiation damage between the two methods. High resolution electron diffraction in MicroED dataset is very sensitive to global damage to 3D protein crystals with low dose accumulation, and its intensity attenuation rates at atomic resolution shell could be applied for estimating site specific damage rate to macromolecules for single particle sample. More in-depth systematically radiation damage assessments using SPA and MicroED will benefit all applications of cryo-EM, especially cellular structure analysis by tomography.

8,308 views

11 citations

DeepHEMNMA: ResNet-based hybrid analysis of continuous conformational heterogeneity in cryo-EM single particle images
Single-particle cryo-electron microscopy (cryo-EM) is a technique for biomolecular structure reconstruction from vitrified samples containing many copies of a biomolecular complex (known as single particles) at random unknown 3D orientations and positions. Cryo-EM allows reconstructing multiple conformations of the complexes from images of the same sample, which usually requires many rounds of 2D and 3D classifications to disentangle and interpret the combined conformational, orientational, and translational heterogeneity. The elucidation of different conformations is the key to understand molecular mechanisms behind the biological functions of the complexes and the key to novel drug discovery. Continuous conformational heterogeneity, due to gradual conformational transitions giving raise to many intermediate conformational states of the complexes, is both an obstacle for high-resolution 3D reconstruction of the conformational states and an opportunity to obtain information about multiple coexisting conformational states at once. HEMNMA method, specifically developed for analyzing continuous conformational heterogeneity in cryo-EM, determines the conformation, orientation, and position of the complex in each single particle image by image analysis using normal modes (the motion directions simulated for a given atomic structure or EM map), which in turn allows determining the full conformational space of the complex but at the price of high computational cost. In this article, we present a new method, referred to as DeepHEMNMA, which speeds up HEMNMA by combining it with a residual neural network (ResNet) based deep learning approach. The performance of DeepHEMNMA is shown using synthetic and experimental single particle images.

5,128 views

38 citations

Cryogenic electron microscopy (cryo-EM) single particle analysis has become one of the major techniques used to study high-resolution 3D structures of biological macromolecules. Specimens are generally prepared in a thin layer of vitrified ice by using a holey carbon grid. However, the sample quality using this type of grid is not always ideal for high-resolution imaging even when the specimens in the test tube behave ideally. Various problems occur during a vitrification procedure, including poor/nonuniform distribution of particles, preferred orientation of particles, specimen denaturation/degradation, high background from thick ice, beam-induced motion, etc., which have become important bottlenecks in high-resolution structural studies using cryo-EM in many projects. In recent years, grids with support films made of graphene and its derivatives have been developed to efficiently solve these problems. Here, the various advantages of graphene grids over conventional holey carbon film grids, functionalization of graphene support films, production methods of graphene grids and origins of pristine graphene contamination are reviewed and discussed.

13,104 views

21 citations

The three-dimensional organization of biomolecules important in the function of all living systems can be determined by cryo-electron tomography imaging under native biological contexts. Cryo-electron tomography is continually expanding and evolving, and the development of new methods that use the latest technology for sample thinning is enabling the visualization of ever larger and more complex biological systems, allowing imaging across scales. Quantitative cryo-electron tomography possesses the capability of visualizing the impact of molecular and environmental perturbations in sub-cellular structure and function to understand fundamental biological processes. This review provides an overview of current hardware and software developments that allow quantitative cryo-ET studies, their limitations and how overcoming them may allow us to unleash the full power of cryo-ET.

13,903 views

30 citations