accessible. As systems move away from highly specialized radiology environments, they must also become easier to install, operate, maintain, and interpret. Volume II of the Research Topic on Autonomous Low-field Magnetic Resonance Imaging illustrates this transition. The central challenge extends beyond producing useful low-field images; it requires developing an imaging workflow that is robust, reproducible, and automated enough to operate effectively in environments with limited MRI expertise. Sarty et al. address accessibility by enabling communities to build and maintain low-field MRI hardware locally. Their educational program demonstrated that skills already present in an aircraft-maintenance training environment (including 3D printing, sheet-metal fabrication, and electrical harness construction) were sufficient to build a prototype MRI system. This work expands the meaning of autonomy beyond software. Sustainable low-field MRI requires local technical capacity, modular hardware, transparent documentation, and maintainable systems. Automation can complement this approach by reducing calibration burden, detecting hardware or setup errors, and guiding less specialized users through system checks and acquisition.Workneh et al. examine another, equally important prerequisite for accessible neuroimaging: feasibility and community acceptance. In rural Ethiopia, community members and clinicians viewed MRI and electroencephalography (EEG) positively after being introduced to the technologies, while raising concerns about safety, unfamiliarity, transportation, and participation logistics. Their findings emphasize that successful deployment requires workflows that are understandable, predictable, and compatible with local clinical and social contexts. Automated setup, protocol selection, safety checks, child-friendly guidance, and quality assurance could reduce operator dependence while helping standardize examinations across geographically distributed sites.Two contributions focus directly on overcoming the image-quality and quantitative limitations of low-field MRI using artificial intelligence. Ssentamu et al. introduce native noise denoising, using noise characteristics measured from low-field images to generate training data for a denoising network. The approach improved signal-to-noise ratio across multiple low-field datasets while preserving structural information. Islam et al.evaluate regional brain volumetry from 64 mT MRI and show that AI-based image enhancement reduces systematic differences relative to 3 T measurements. Together, these studies illustrate an important pathway toward autonomous low-field MRI: reconstruction and post-processing should adapt to the characteristics of the acquired data and produce consistent outputs without requiring extensive manual intervention. Future systems will need to integrate such methods with automated quality assessment so that enhancement is not merely visually appealing, but quantitatively reliable and traceable. Finally, Azizi et al. broaden the case for portable low-field MRI by quantifying its environmental impact in remote Canadian settings. Their analysis found substantially lower energy use per examination than conventional fixed MRI and highlighted the potential reduction in transportation-related emissions when patients can be imaged locally. These findings connect accessibility, sustainability, and autonomy. A scanner that requires fewer specialized facilities and avoids long-distance patient transfers can lower both logistical and environmental costs; automation can amplify these advantages by enabling reliable operation with smaller on-site teams and reducing repeat examinations caused by inconsistent acquisition quality.Collectively, the articles in this volume suggest that the next phase of low-field MRI should be defined by systemlevel autonomy. This includes automated hardware calibration and monitoring; protocol selection and parameter adaptation; patient positioning and motion management; acquisition quality control; reconstruction, denoising, and artifact correction; quantitative analysis; and appropriately validated decision support. Importantly, autonomy should not imply removal of human expertise. Rather, it should encode expert knowledge into transparent, failsafe workflows that augment local operators and preserve routes for remote expert oversight when needed. Lowfield MRI has already demonstrated that the physical requirements of MRI can be reduced. The next step is to reduce its operational complexity. Doing so will be essential if low-field MRI is to scale from promising demonstrations to dependable, sustainable imaging systems that can expand access across diverse clinical and geographic settings.
Editorial12 November 2026
Editorial: Autonomous low-field magnetic resonance imaging, volume IIThis study compares volumetric measurements of various brain regions using different magnetic resonance imaging (MRI) modalities and deep learning models, specifically 3T MRI, ultra-low field (ULF) MRI at 64mT, and AI-enhanced ULF MRI using SynthSR and HiLoResGAN. The aim is to evaluate the alignment and agreement among field strengths and ULF MRI with and without AI. Descriptive statistics, paired t-tests, effect size analyses, and regression analyses are employed to assess the relationships and differences between modalities. The results indicate that volumetric measurements derived from 64mT MRI deviate significantly from those obtained using 3T MRI. By leveraging SynthSR and LoHiResGAN models, these deviations are reduced, bringing the volumetric estimates closer to those obtained from 3T MRI, which serves as the reference standard for brain volume quantification. These findings highlight that deep learning models can reduce systematic differences in brain volume measurements across field strengths, providing potential solutions to minimize bias in imaging studies.