Editorial: POCUS for neonates - advancing care with point-of-care ultrasound
Editorial28 October 2025
Editorial: POCUS for neonates - advancing care with point-of-care ultrasound

The clinical application of point-of-care ultrasound (POCUS) in neonatology has expanded dramatically over the recent decade, driven by the easy availability of portable machines and its proven value in making better physiology-based clinical decisions. POCUS has been demonstrated to be superior to chest X-rays and other bedside available tools in making accurate diagnoses, targeting specific interventions, and enhancing procedure safety. Its ability to perform serial evaluations helps in understanding the disease process and evaluating the response to intervention.Beyond diagnostics, POCUS enhances procedural success rates for central line placement, lumbar puncture, and thoracentesis, reducing complications compared to traditional 'blind' techniques. Its radiation-free nature also makes it a safer alternative to CT scan or X-ray, particularly for newborns. These benefits make POCUS an attractive imaging tool in the intensive care unit.However, neonatal POCUS lags behind as compared to adult medicine. To promote a safe use of POCUS and enhance clinical governance, the European Society of Pediatric and Neonatal Intensive Care (ESPNIC) society issued the first international evidence-based guidelines on use of POCUS in neonatal and pediatric intensive care units (2020), followed by the American Academy of Pediatrics (AAP) clinical and technical reports (2022) 1,2 . There remains uncertainty about whether widespread adoption will improve the outcomes in the NICU. This Research Topic, 'POCUS for Neonates: Advancing Care with Point-of-Care Ultrasound,' brings together 10 peer-reviewed articles that enhance knowledge on how POCUS can be utilized for accurate and timely diagnosis, guide interventions, and improve decisionmaking in the NICU. Battacharjee et al. reported that repeated X-ray exposure was linked to developmental delay, underscoring the value of radiation-free imaging such as POCUS. Beyond being a reliable diagnostic and procedural tool, [1][2] Tomaszkiewicz et al. performed outcomes studies showing that POCUS impacts care by enhancing efficiency in umbilical venous catheter placement and reducing complications. LUS with qualitative scoring has been widely used for decades to predict surfactant need in preterm infants with respiratory distress syndrome, but standardized approaches remain lacking. 3 Several studies here focused on LUS protocol standardization and application validation. With the availability of ultra-high-frequency probes (UHFUS) (~30-70 MHz), neonatal POCUS is less limited by the small size and superficial location of neonatal structures. UHFUS offers significantly higher spatial resolution for very superficial tissues (typical penetration of ~1-3 cm) and has demonstrated feasibility in pediatric and neonatal imaging of lung, gastrointestinal, and musculoskeletal imaging. 5,6 As POCUS applications expand, research must also address effective methods for delivering high-quality and most efficient training for the clinicians.The pace of innovation in technology used in the medical field, especially in imaging, is extremely fast. Application of Artificial Intelligence (AI) can help address operator dependence, variability in image quality, and challenges in quantitative analysis that characterize POCUS. The AI applications include better imaging optimization, help with the best possible imaging acquisition, rapid image analysis, and data processing. 7,8 Enhanced AI applications include realtime acquisition guidance that provides step-by-step feedback for probe placement and automatically stores optimal images. 7,8 This will help in POCUS training for new users, especially those in low-resource areas, which is another important POCUS research area. Other automated tools offer functions such as B-line counting for lung ultrasound scoring, inferior vena cava (IVC) compressibility assessment for intravascular volume status, velocity-time integral (VTI) calculations for cardiac output, and real-time ejection fraction (EF) measurements. Chan et al. developed an algorithm to automatically quantify the proportion of anechoic cerebrospinal fluid within the spinal canal to correlate with intraventricular hemorrhage severity. 9 All these tools still require extensive validation due to both known and unknown limitations, particularly the inadequate neonatal data pool for machine learning. Despite these advances, several limitations hinder the widespread clinical adoption of AIenabled POCUS. Most models are trained on relatively small or homogeneous datasets, which limits generalizability across diverse patient populations, ultrasound machines, and clinical settings. The volume of neonatal imaging data available for machine learning remains insufficient, and many automated tools have not been adapted for neonatal physiology. Addressing these limitations through multicenter validation, transparent algorithm design, and thoughtful clinical integration will be critical for AI to achieve its potential in the field of ultrasonography.In this editorial, we reflect on the rapidly evolving role of POCUS, some of the araes featured in this Research Topic, and outline future directions. POCUS is changing the way clinicians practice in the intensive care unit; however, continued investigation is essential to strengthen the body of evidence around its impact on improving patient outcomes. Future directions should include studies focused on patient outcomes, standardization of clinical applications, validation of guidelines and protocols, quality assurance, technological innovation, and how best to provide POCUS training. (Figure 1)

2,130 views

1 citations

Real-time ultrasound guidance improves neonatal umbilical venous catheter placement efficiency and reduces liver complications
IntroductionUmbilical venous catheters (UVCs) are essential in neonatal intensive care, yet blind insertion techniques remain common and increase the risk of malposition and liver injury. This study evaluated whether real-time ultrasound guidance improves UVC placement efficiency and safety.MethodsWe retrospectively analysed 305 neonates who underwent ultrasound-guided UVC placement between July 2023 and January 2025 in a tertiary neonatal unit. The primary outcome was successful tip placement in the subdiaphragmatic vestibule; the secondary outcome was acute catheter-related liver injury.ResultsCorrect catheter placement was achieved in 86.56% of cases, with a gradual improvement from 83.81% to 89.12% over time. Only one hepatic haematoma was observed, and no other acute complications occurred.DiscussionReal-time ultrasound guidance significantly enhances the accuracy and safety of UVC insertion in neonates, minimising hepatic injury risk. Further research should assess its role in prolonged catheter monitoring.

2,763 views

4 citations

Neurodevelopmental impact of early diagnostic imaging in preterm infants: quantifying risk and the role of point-of-care ultrasound
ORIGINAL RESEARCH
20 August 2025
Neurodevelopmental impact of early diagnostic imaging in preterm infants: quantifying risk and the role of point-of-care ultrasound
Indrani Bhattacharjee, 3 more and Paige Church

3,717 views

4 citations

ORIGINAL RESEARCH
13 August 2025
Neonatal evaluation by extended (12 area) vs. traditional (6 area) lung ultrasound scoring (NEXT-LUS): a prospective observational study
Chinmay Chetan, 5 more and Saikat Patra
Neonatal evaluation by extended (12 area) vs. traditional (6 area) lung ultrasound scoring (NEXT-LUS): a prospective observational study
BackgroundLung ultrasound (LUS) offers a safe, repeatable, radiation-free tool in management of respiratory distress in neonates. Despite wide use, limited data exists on optimal scoring approaches.MethodologyA prospective observational study was conducted over 6 months in a tertiary neonatal intensive care unit (NICU) enrolling neonates with respiratory distress within 2 h of admission after consent. LUS was performed using both 6-area and 12-area scanning approaches. Scores were assigned per Brat's criteria. Primary outcome was prediction of need for invasive ventilation within 72 h. Secondary outcomes included optimal cut-off scores, correlation with clinical outcomes and procedural safety.ResultsAmong 73 neonates enrolled, the 6-area LUS score (cut-off ≥5) predicted invasive mechanical ventilation within 72 h with 75% sensitivity and 67% specificity (AUC = 0.76). The 12-area score (cut-off ≥13) had similar accuracy (sensitivity 75%, specificity 73%; AUC = 0.77). Both 6-area and 12-area scores performed better in neonates <34 weeks (AUCs: 0.83 vs. 0.86). In neonates presenting after 24 h of life (n = 19), both scores maintained good accuracy (AUCs: 0.80 for 6-area, 0.83 for 12-area). Multivariate analysis identified partial pressure of carbon dioxide (pCO2) and duration of stay as independent predictors. The 12-area score required reattempts (in 9% cases) unlike the 6-area score.ConclusionIn neonates presenting with respiratory distress, 6-area and 12-area LUS scores done within 2 h of admission show good and comparable predictive value regarding need for invasive ventilation by 72 h.

3,286 views

3 citations

Diagnostic value of prenatal ultrasound in the typing of fetal esophageal atresia
ORIGINAL RESEARCH
29 July 2025
Diagnostic value of prenatal ultrasound in the typing of fetal esophageal atresia
Lijun Song, 5 more and Hong Yin
ObjectiveTo investigate the prenatal ultrasound image features and diagnostic value of fetal esophageal atresia (EA).MethodsThe clinical and prenatal ultrasound data of 24 fetuses with suspected esophageal atresia diagnosed by prenatal ultrasound and/or postpartum ultrasound at Shandong Maternal and Child Health Hospital between February 2022 and November 2024 were retrospectively analyzed, and the prenatal ultrasound diagnostic characteristics of different types of esophageal atresia were reviewed retrospectively.ResultsTwenty-four cases of esophageal atresia were detected by prenatal and/or postpartum ultrasound. Among the 11 patients who were lost to follow-up or with no clear diagnosis after birth, the confirmation rate with prenatal ultrasound was 92% (12) among the 13 cases with confirmation by postpartum surgery or anatomy, with a classification concordance rate of 77% (10/13). Two cases of type IIIA EA were misdiagnosed as type IIIB, and one case of type IIIB EA was missed. The proportion of other malformations was 77% (10/13), and the detection rate of chromosomal abnormalities was 15% (2/13).ConclusionPrenatal ultrasound can be used to diagnose and assess the classification and combined malformations of esophageal atresia effectively, providing an strong basis for clinical decision-making.

3,657 views

2 citations

Case Report: From diagnosis to therapy: a lung ultrasound-driven precision strategy for neonatal atelectasis management
CASE REPORT
5 June 2025
Case Report: From diagnosis to therapy: a lung ultrasound-driven precision strategy for neonatal atelectasis management
Qi Chen, 1 more and Li Jun
ObjectiveTo examine the clinical value of lung ultrasound (LUS) in the individualized management of neonatal atelectasis and assess its effectiveness in directing condition-specific treatment strategies.MethodsThree neonatal atelectasis cases with differing causes, pneumonia, pulmonary hemorrhage, and meconium aspiration syndrome, were treated with LUS-guided, personalized interventions. These included ultrasound-directed airway clearance, selective bronchoalveolar lavage, and high-frequency chest wall oscillation.ResultsLUS enabled continuous, real-time assessment of atelectasis severity and distinct pathological signs such as hepatization and the shred sign. This imaging guidance allowed targeted therapies that shortened hospitalization by an average of 40%. In all cases, lung re-expansion was achieved without adverse events.ConclusionDue to its lack of radiation, high sensitivity, and real-time feedback, LUS offers a valuable tool for guiding individualized, etiology-specific therapies in neonatal atelectasis. It presents a clinically adaptable approach for optimizing outcomes in this population.

3,627 views

3 citations

CASE REPORT
6 February 2025
Case report: Ultrasound and contrast-enhanced ultrasound findings of pediatric small intestinal inflammatory myofibroblastic tumor
Zengmiao Xing, 1 more and Lingling Qin

2,307 views

2 citations