Skip to main content

Minimally Invasive Pediatric Surgery: How To Improve and Overcome Limitations

57kviews
Editorial17 July 2024
Editorial: Minimally invasive pediatric surgery: how to improve and overcome limitations

The evolution of minimally invasive pediatric surgery is one of modern medicine's most exciting and progressive chapters. This practice, which originated in the development of laparoscopic surgery in adults in the 1980s, has gained a prominent position in the care of pediatric patients because of its many advantages over more invasive traditional surgical approaches. Minimally invasive pediatric surgery began to take shape in the 1990s, with the adoption of laparoscopic techniques for simple surgeries such as appendectomy and cholecystectomy. An important milestone was set in 1995 when van der Zee performed the first laparoscopic CDH repair (1). Since then, it has seen a wide expansion in techniques and applications, ranging from gastrointestinal to urological and thoracic surgeries. After that, surgical techniques have undergone continuous improvements, up to unimaginable goals, such as performing robotic-assisted surgical procedures on patients under the age of one. Technological advances have played a crucial role in the evolution of minimally invasive pediatric surgery (2). Miniaturization of surgical instruments and improvements in imaging technologies have made operating safe even in the smallest patients possible. Robotics and augmented reality systems are now frequently integrated to improve the precision and effectiveness of surgery. Robot-assisted surgery, in particular, has enabled a further decrease in incision size and an increase in precision, thanks to robotic arms that eliminate the natural tremor of the human hand and allow extremely controlled and delicate movements. The evolution of techniques and knowledge has made it possible to overcome barriers, operating with minimally invasive techniques on small patients with complex pathologies (3,4). The clinical results of pediatric minimally invasive surgery have been extraordinary. Several studies have shown that children undergoing minimally invasive procedures experience less postoperative pain, have lower risks of infection, and enjoy faster convalescence than those treated with traditional techniques (5,6). In addition, the reduced visual impact of scars contributes positively to young patients' psychological acceptance of surgical treatment.The goal of this special issue was to collect publications that could best describe and summarize not only the evolution of minimally invasive pediatric surgery but also set goals for future developments.Robot-assisted surgery has made it easier for pediatric surgeons to perform essential reconstructive-type procedures. One of the most significant examples is ureterovesical junction surgery, in which the robotic approach demonstrates its advantages. In their work, He et al. described how the technique of modified Lich-Gregoir direct nipple ureteral extravesical reimplantation can help maintain the physiological direction of the ureter and at the same time enhance the effectiveness of antireflux in robotic surgery. In addition, design of a single-port-plus-one wound can produce a cosmetic appearance by concentrating and hiding the wound around the umbilicus. This modified reimplantation procedure has the potential to become a promising technique in the robot-assisted treatment of primary obstructive megaureter.Robot-assisted surgery is also catching on in the field of oncology surgery, in selected cases, showing the same good results as in other areas. Liang et al. described a case of a 3-year-old patient with a periampullary rhabdomyosarcoma who underwent a robotic pylorus-preserving pancreatoduodenectomy. With the assistance of a modern robotic system, they performed an R0 resection and a reconstruction with end-to-end pancreatojejunostomy, end-to-side hepaticojejunostomy, and duodenojejunostomy, without fatal complications such as pancreatic fistula or leak. The reported case demonstrates that this kind of procedure in pediatric patients is also safe and effective without intra-or postoperative complications.An important part of minimally invasive surgery remains the domain of techniques such as laparoscopy and thoracoscopy. In this special issue, we have collected interesting experiences from this point of view. Laparoscopic herniorrhaphy in pediatric patients has become a routine procedure, often performed in day surgery. Zhang et al. reported a large series of 848 patients undergoing single-port laparoscopic herniorrhaphy. They described satisfactory results with no cases of conversion and 2 patients presenting with recurrence. They stated that this intervention presents numerous benefits, including the utilization of uncomplicated instruments, straightforward operation, a clear curative impact, minimal tissue damage, rapid recovery, and the absence of scarring. Another interesting example is that of Jung, who reports the case of a newborn presented with a rare combination of esophageal atresia with tracheoesophageal fistula and duodenal atresia, which was successfully managed using minimally invasive surgical techniques. The neonate underwent a thoracoscopic ligation of the tracheoesophageal fistula (TEF) and a laparoscopic duodeno-duodenostomy on the same day, resulting in stabilized vital signs. Ten days after the initial operation, a thoracoscopic esophago-esophagostomy was successfully performed. This report details a recent successful experience with a two-stage operation conducted without gastrostomy and utilizing minimally invasive surgical techniques. This approach underscores the evolving potential for neonatal treatment strategies in managing such complex cases.Talking about minimally invasive surgery also means addressing how to enable surgeons, starting with residents, to acquire a progressive learning curve to make them autonomous even in the most complex cases. In this sense, the development of training programs involving faithful anatomical models becomes essential to ensure the development of the basic skills needed to approach this type of procedure. In this special issue, we have collected two original types of research dealing with different aspects of the same topic. Zahradnikova et al created a 3D printed model for thoracoscopic repair of esophageal atresia with tracheoesophageal fistula and created a program in which 18 participants with different surgical experiences practiced. The results emphasized that this type of model proved useful as a training tool, partly because of its realism. The authors stated that due to its reusability, and suitability for individual participants, this model holds promise as a training tool for thoracoscopic procedures among surgeons. Miyano et al., on the other hand, described a cadaver teaching program to evaluate the usefulness of remote teaching. The results of their study show, that although inferior to hands-on practice, remote observation of minimally invasive procedures provides good results and can be particularly useful for training programs in resource-limited settings.Lastly, when talking about pediatric minimally invasive surgery, and addressing the topic of what its developments might be, the focus on patients cannot be lost sight of. Pediatric patients require different management and attention than adults, and to neglect this is to disregard the overall health of patients. From this point of view, one of the main aspects is the management of the patient's preoperative anxiety. Franconi et al., designed a study, using a humanoid robot that would interact with patients, accompanying them as they entered the operating room. The purpose of this study was to determine whether the use of a humanoid robot could reduce preoperative anxiety levels in children. This work had the interesting result of showing that a non-pharmacological intervention like a humanoid robot reduces anxiety in children during the pre-operative time and it might be an attractive solution to optimize perioperative care in children.In conclusion, we can say that the success of this Special Issue, in addition to the important number of articles collected, also lies in the fact that it has shown how minimally invasive surgery, even in pediatric settings, is a field where important milestones have been achieved, without ceasing to look toward future goals of further development.

2,044 views

6 citations

ORIGINAL RESEARCH
10 January 2024
Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations
Weiwei Yang, 4 more and Yang Li
Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations
Purpose: Olecranon fracture is considered intra-articular when there is obvious displacement or an irregular articular surface. Such fractures should be reduced and fixed via surgery. No clear indications regarding the surgical technique to be adopted exist. Therefore, this study aimed to compare the outcomes of tension band wiring (TBW) and Herbert screw fixations for olecranon fractures.We retrospectively analyzed the clinical data of 29 children with olecranon fractures. They were divided into the tension band wiring and Herbert screw groups. We assessed early epiphyseal closure and maximum length of the ulna using radiography. Patients were clinically evaluated using the average QuickDASH score.Results: Both groups had good radiological outcomes. Herbert screws demonstrated advantages in terms of bleeding, operative time, intraoperative blood loss, surgery duration, and particularly the QuickDASH score (1.57 vs. 4.18, p < 0.05). Complications, including needle loosening and bursitis, occurred in five cases in the TBW group. Six cases had premature physis plate closure, and no difference was observed in limb length at 6 months after surgery.Compared with TBW, Hebert screws demonstrated better clinical outcomes and lesser postoperative complications in the treatment of ulnar olecranon fractures in children. However, long-term follow-up is required to assess the effects of screws on the ulnar physis plate and ulna length.

3,537 views

9 citations

To use a simple hernia needle for single-port laparoscopic percutaneous inguinal hernia repair in children: a 5-year experience study
ORIGINAL RESEARCH
8 January 2024
To use a simple hernia needle for single-port laparoscopic percutaneous inguinal hernia repair in children: a 5-year experience study
Li Zhang, 5 more and Saihua Li

3,396 views

13 citations

Preoperative anxiety management in children. Benefits of humanoid robots: an experimental study
ORIGINAL RESEARCH
8 December 2023
Preoperative anxiety management in children. Benefits of humanoid robots: an experimental study
Ilaria Franconi, 7 more and Flavia Carle
Objective The purpose of this study was to determine whether the use of a humanoid robot (Estrabot) could reduce preoperative anxiety levels in children. Methods An experimental study was conducted at Azienda Ospedaliero Universitaria delle Marche Hospital, involving the Pediatric Surgery ward and the Operating Room (OR). The clinical documentation of patients aged between 2 and 14 years who underwent minor surgery was included. The Instruments used were the Children's Emotional Manifestation Scale to evaluate anxiety levels, and Estrabot, a humanoid robot that interacts with people. Medical records between July 2019 and February 2020 were analyzed and the data was anonymous. The level of anxiety is extrapolated in Pediatric Surgery during the administration of oral pre-medication, and in the Operating Room, during the induction of anesthesia. Patients were divided into an intervention group treated with Estrabot, and a control group without a robot. Results The population consists of 60 patients (86.7%) with a median (IQR) age of 6 (4-8) years The median (IQR) anxiety score during premedication was 7 (5-11), while the median (IQR) anxiety score during anesthesia was 6 (5-10). A significantly lower level of anxiety was reported in the Estrabot group both during oral premedication and anesthesia administration. Patients in the Estrabot group had significantly lower anxiety levels in both age groups (less than 8 years and more or equal to 8 years). Conclusion A humanoid robot can reduce preoperative anxiety levels in children during premedication and the induction of anesthesia.

3,899 views

9 citations

ORIGINAL RESEARCH
23 November 2023
Percutaneous transthoracic catheter drainage prior to surgery in treating neonates with congenital macrocystic lung malformation presenting with respiratory distress
Taozhen He, 6 more and Chang Xu

1,715 views

5 citations

Inanimate 3D printed model for thoracoscopic repair of esophageal atresia with tracheoesophageal fistula
ORIGINAL RESEARCH
14 November 2023
Inanimate 3D printed model for thoracoscopic repair of esophageal atresia with tracheoesophageal fistula
Petra Zahradniková, 6 more and Barbora Nedomová
Inanimate 3D Printed Model for Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula Abstract Background Thoracoscopic esophageal atresia (EA)/tracheoesophageal fistula (TEF) repair is technically challenging. The purposes of this study were to create an inexpensive, reusable, high-fidelity synthetic tissue EA/TEF repair simulation model and to evaluate the validity of this simulator. Method We have developed a new inanimate inexpensive easy reusable model designed for training of thoracoscopic repair of EA/TEF. The goal of this study was to validate this model using 5-point Likert scale validation and objective structured assessment of technical skills (OATS) for participants’ surgical performance. Results A total of 17 participants after instructions and training were asked to perform TEF ligation, dissection and esophageal anastomosis using six sliding knots on the EA/TEF simulator. Six medical students, 4 pediatric surgery trainees and 7 experienced surgeons were enrolled in this study. All participants in the consultant group completed the task within the allotted 120-min period; however, only one participant from inexperienced group completed the task within the time limit. There was a statistically significant difference in OSATS scores for the ‘flow of task’ (p = 0.018) and scores for the ‘MIS skills’ (p = 0.010) task distinguishing between novice and intermediates and experts. The simulator showed good content validity; its usefulness as a training tool for EA/TEF, with the mean score of 4.68. The mean scores for realism of the model and working environment were 4.25 and 4.5, respectively. Conclusions Our study demonstrated good face and content validity. As our model is inexpensive, reusable, easily replaceable for each participant it seems to as that it holds real potential as a thoracoscopic training device for surgeons. However, novices and trainees were not able to finished advanced MIS procedure. Therefore, a structured and focused training curriculum in pediatric MIS is needed for optimal utilization of the available training hours.

3,261 views

17 citations

Single-port-plus-one robot-assisted laparoscopic modified Lich-Gregoir direct nipple ureteral extravesical reimplantation in children with a primary obstructive megaureter
ORIGINAL RESEARCH
2 November 2023
Single-port-plus-one robot-assisted laparoscopic modified Lich-Gregoir direct nipple ureteral extravesical reimplantation in children with a primary obstructive megaureter
Yufeng He, 6 more and Di Xu
To introduce a new technique of single-port-plus-one robotic laparoscopic modified Lich-Gregoir direct nipple ureteral extravesical reimplantation and verify its validity in the treatment of pediatric primary obstructive megaureter. Methods: Retrospectively analyzed the clinical data of 12 children with primary obstructive megaureter admitted to the Department of Pediatric Surgery of Fujian Provincial Hospital from January 2021 to November 2021. 12 children were treated with single-port-plus-one robotic laparoscopic Lich-Gregoir direct nipple ureteral extravesical reimplantation. Five of them were female and seven were male, including nine obstructive cases and three obstructive with reflux cases. The mean age was 17.33 ± 6.99 (10-36) months and the mean follow-up time was 14.16 ± 1.75 (12-17) months. Changes in parameters preoperative and 1 st year postoperative were compared. Results: The mean operative time for the 12 children was 123.58 ± 10.85 (110-145) min, with a mean internal operative time of 101.42 ± 0.85 (90-120) min, mean operative bleeding of 2.42 ± 0.67 (2-4) ml and mean haematuria duration of 16.08 ± 1.44 (14~19) hours, mean Indwelling catheterization time was 2.25 ± 0.45 (2~3) days and mean hospitalization were 3.83 ± 0.39 (3~4) days. At 1 st year postoperative, the ureteral diameter, calyceal diameter, and APRPD were significantly smaller than preoperative (18.83 ± 3.21 mm vs 6.83 ± 1.27 mm, 13.99±3.58mm vs 3.5±2.90mm and 34.92 ± 4.25 mm vs 10.08 ± 1.88 mm, P<0.001). Renal cortical thickness and DRF % were significantly increased (3.63±1.66mm vs 5.67±1.88mm,33.75 ± 2.77 mm vs 37.50 ± 1.31 mm, P <0.001). The resolution rate of obstruction was 100% and no one develop developed DeNovo VUR. Conclusion: The technique of modified Lich-Gregoir direct nipple ureteral extravesical reimplantation can remain maintain the physiological direction of the ureter and enhance the effectiveness of anti-refluxing at the same time in robot surgery. The design of a single-port-plus-one wound can produce a cosmetic appearance by concentrating and hiding the wound around the umbilicus. This modified surgery may become a promising used surgery in the robot-assisted treatment of POM.

2,963 views

7 citations

ORIGINAL RESEARCH
9 October 2023
Remote cadaveric minimally invasive surgical training
Go Miyano, 10 more and Tadaharu Okazaki

2,162 views

2 citations

CASE REPORT
21 July 2023
Case report: Laparoscopic nissen-sleeve gastrectomy in a young adult with incidental finding of Morgagni-Larrey hernia
Rossella Palma, 5 more and Luigi Angrisani

2,242 views

4 citations

CASE REPORT
27 June 2023
Case report: Minimally invasive removal of a dislodged thoracoamniotic shunt with an integral cystoscope in a preterm infant
Lichao Zhu, 4 more and Feng Guo

2,582 views

ORIGINAL RESEARCH
4 October 2023
Comparative assessment of fully laparoscopic Duhamel-Z with minimal rectorectal dissection vs. laparoscopy-assisted Duhamel-Z with blunt manual rectorectal dissection for total colonic aganglionosis
Go Miyano, 8 more and Tadaharu Okazaki

2,240 views