Developing Novel Materials and New Techniques of Biological and Physical Retrospective Dosimetry for Affected Individuals in Radiological and Nuclear Emergencies

32kviews
Editorial05 January 2023
Editorial: Developing novel materials and new techniques of biological and physical retrospective dosimetry for affected individuals in radiological and nuclear emergencies

Retrospective dosimetry estimates radiation doses received by an individual in the past using physical and biological methods. Because of the increasing threat of radiological accidents or terrorist attacks involving radioactive material, the development of this area of research has become extremely important (1,2). This research topic, entitled "Developing Novel Materials and New Techniques of Biological and Physical Retrospective Dosimetry for Affected Individuals in Radiological and Nuclear Emergencies," provided an opportunity to receive new relevant contributions from various experts who provided new insights and perspectives in the field of retrospective dosimetry. The aim was to connect more scientific fields, researchers and infrastructures from this interdisciplinary research area and to collect studies relevant to human health. The main objective is to improve complementary physical and biological measurement techniques with lower detection limits of received radiation doses, to characterize different appropriate dosimeters, to develop and validate individual dose estimation models, and to propose standardized dosimetry protocols required in the most likely scenarios. It also aims to estimate more accurately radiation dose received by individuals involved in a nuclear accident or radiological emergency using materials on or near the victim and the victim's blood in a relatively short period of time to allow appropriate medical treatment and therapy to increase survival rates. In the manuscript by Chaurasia et al., the authors propose the detection and quantification of 94 phospho-53BP1 foci as a rapid and sensitive biological dosimetry method. For this purpose, γ-ray-95 induced dose-response curves were generated and validated at different time points. The study also 96 includes comparative evaluations of the generated calibration curve with the γH2AX-foci assay and 97 cytogenetic assays by estimating doses from dose-blinded samples. The authors suggest the use of 98 the phospho-53BP1 foci calibration curve for rapid biological dosimetry in radiological emergencies 99 and medical exposures. 100Another system to reduce analysis time is the use of automated or semi-automated equipment. 101Automation of metaphase determination, image capturing, and aberration scoring has proven 102 successful and is used in many biodosimetry laboratories. In this context, an interesting work by Lee 103 and coworkers has been incorporated into this research topic. In their study, the performance of a 104 semi-automatic scoring method for dicentrics using ex vivo and in vivo irradiated samples was 105 compared to the standard manual scoring method. Although the semiautomated scoring method 106 requires additional testing to correct for false positives, their results indicate that the semiautomated 107 scoring method can rapidly provide an accurate dose estimate and could be useful as an alternative to 108 the manual dicentric assay for biodosimetry in large-scale radiological accidents. 109In addition, Buchner indicated in their study that the orientation of the blood sample tubes 110 (vertical vs. horizontal) had a significant effect on radiation dose with a variation from -41% to +49% 111 and contributed to a dose gradient of up to 870 mGy within the vertical tubes due to the size of the 112 sample tubes and the associated differences in the distance from the focal point of the tube. As a 113 result, the number of dicentric chromosomes and micronuclei differed by ~30% between the two 114 orientations. Therefore, careful examination of the experimental setup in collaboration with 115 physicists was suggested to ensure traceability and reproducibility of the irradiation conditions, to 116 correctly correlate the radiation dose and the number of aberrations, and to avoid systematic biases 117 that affect dose estimation in the context of biological dosimetry. 118According to these findings, it can be suggested as a conclusion that close cooperation 119 between a wide range of researchers and infrastructures is needed to achieve the main goal of urgent, 120 appropriate and adequate medical treatment of victims of radiological and nuclear accidents. 121

1,424 views

2 citations

Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure
ORIGINAL RESEARCH
20 October 2022
Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure
Younghyun Lee, 5 more and Seongjae Jang

3,307 views

15 citations

ORIGINAL RESEARCH
17 November 2022
Comparison of three methods of EPR retrospective dosimetry in watch glass
Agnieszka Marciniak, 3 more and Jakub Karczewski

2,334 views

3 citations

ORIGINAL RESEARCH
15 September 2022
Mobile phone screen protector glass: A TL investigation of the intrinsic background signal
Céline Bassinet, 2 more and Clemens Woda
Screen protector glasses are often used to protect the display screen surface of mobile phones against physical damage. Their dosimetric properties were recently studied by thermoluminescence with the aim of using these items as potential emergency dosimeters in the event of a radiological accident. They are sensitive to ionizing radiation and they could be easily removed and replaced without destroying the phone in case of a dose assessment. However, an intrinsic background signal that partially overlaps with the radiation-induced TL signal is observed. The reconstructed dose could be overestimated if not properly taken into account. The homogeneity of this confounding signal on the surface of several screen protectors was estimated and a chemical treatment with hydrofluoric acid (HF 40%) was tested to minimize its contribution. For most of the samples studied, the intrinsic background signal remained a serious issue for dose reconstruction. Additionally, the TL signals were measured in the red detector range using two different models of red-sensitive photomultiplier tubes. The homogeneity of the intrinsic background signal on the surface of screen protectors was examined and the results of the reduction of this signal by the chemical HF treatment were discussed.
Mobile phone screen protector glass: A TL investigation of the intrinsic background signal

4,745 views

16 citations

Establishment of in vitro Calibration Curve for 60Co-γ-rays Induced Phospho-53BP1 Foci, Rapid Biodosimetry and Initial Triage, and Comparative Evaluations With γH2AX and Cytogenetic Assays
A rapid and reliable method for biodosimetry of populations exposed to ionising radiation in the event of an incident or accident is crucial for initial triage and medical attention/management. DNA-Double Strand Breaks (DSBs) are known to be radiation specific and DSB-repair proteins (53BP1, gamma H2AX, ATM, etc) are considered as promising markers of DSB quantification. Immunofluorescence technique serves as a sensitive and reproducible tool for the detection and quantification of these DSB-repair proteins which can be used for biological dose estimations. In this study, Dose Response Curves (DRCs) were generated for 60Co-gamma-rays induced phosphorylation of 53 Binding Protein 1 (53BP1) at 1, 2, 4, 8, 16 and 24 h, post irradiation, for dose range 0.05 - 4 Gy, using fluorescence microscopy. Following ISO recommendations, Minimum Detection Limits (MDLs) were estimated to be 16, 18, 25, 40, 50 and 75 mGy for DRCs generated at 1, 2, 4, 8, 16 and 24 h, post irradiation. Colocalization and correlation of phosphorylated 53BP1 and gamma H2AX was also illustrated in irradiated lymphocytes, to gain dual conformation. Multiparametric validation of the established curve was made by gamma H2AX-immunofluorescence, Dicentric Chromosomal Aberration (DCA) and Reciprocal Chromosomal Translocations (RCT) assays, through 6 dose blinded samples. Respective, in house established DRCs were employed to reconstruct the doses. Estimated doses were found to be within the variation of 4.1 - 24 %. For lower doses (0.05 - 2 Gy), immunofluorescence assays (53BP1 and gamma H2AX) gave closer estimates (variation, - 4.1 to + 9 %) in comparison to cytogenetic assays (variation, - 8.5 to 24 %) and for higher doses (3 and 4 Gy) cytogenetic and immunofluorescence, both the assays gave comparable close estimates, with - 11.3 to + 14.3 % and - 10.3 to - 13.7 %, variations, respectively.

3,311 views

23 citations

BRIEF RESEARCH REPORT
30 August 2022
The use of portable OSL and IRSL measurements of NaCl in low dose assessments following a radiological or nuclear emergency
Hamdan Alghamdi, 3 more and L. Martin

3,338 views

10 citations

ORIGINAL RESEARCH
17 May 2022
Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays
Martin Bucher, 7 more and Ursula Oestreicher
Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays
In biological dosimetry, dose-response curves are essential for reliable retrospective dose estimation of individual exposure in case of a radiation accident. Therefore, blood samples are irradiated in vitro and evaluated based on the applied assay. Accurate physical dosimetry of the irradiation performance is a critical part of the experimental procedure and is influenced by the experimental setup, especially when X-ray cabinets are used. The aim of this study was to investigate variations and pitfalls associated with the experimental setups used to establish calibration curves in biological dosimetry with X-ray cabinets. In this study, irradiation was performed with an X-ray source (195 kV, 10 mA, 0.5 mm Cu filter, dose rate 0.52 Gy/min, 1st and 2nd half-value layer = 1.01 and 1.76 mm Cu, respectively, average energy 86.9 keV). Blood collection tubes were irradiated with a dose of 1 Gy in vertical or horizontal orientation in the center of the beam area with or without usage of an additional fan heater. To evaluate the influence of the setups, physical dose measurements using thermoluminescence dosimeters, electron paramagnetic resonance dosimetry and ionization chamber as well as biological effects, quantified by dicentric chromosomes and micronuclei, were compared. This study revealed that the orientation of the sample tubes (vertical vs. horizontal) had a significant effect on the radiation dose with a variation of -41% up to +49% and contributed to a dose gradient of up to 870 mGy inside the vertical tubes due to the size of the sample tubes and the associated differences in the distance to the focal point of the tube. The number of dicentric chromosomes and micronuclei differed by approximately 30% between both orientations. An additional fan heater had no consistent impact. Therefore, dosimetric monitoring of experimental irradiation setups is mandatory prior to the establishment of calibration curves in biological dosimetry. Careful consideration of the experimental setup in collaboration with physicists is required to ensure traceability and reproducibility of irradiation conditions, to correlate the radiation dose and the number of aberrations correctly and to avoid systematical bias influencing the dose estimation in the frame of biological dosimetry.

3,418 views

7 citations