ORIGINAL RESEARCH article

Front. Physiol., 09 April 2018

Sec. Clinical and Translational Physiology

Volume 9 - 2018 | https://doi.org/10.3389/fphys.2018.00353

Modeling Arterial Pulse Pressure From Heart Rate During Sympathetic Activation by Progressive Central Hypovolemia

  • 1. Department of Internal Medicine, Academic Medical Center, Amsterdam, Netherlands

  • 2. Department of Medical Biology, Academic Medical Center, Amsterdam, Netherlands

  • 3. Laboratory for Clinical Cardiovascular Physiology, Academic Medical Center, Amsterdam, Netherlands

  • 4. Department of Anesthesiology, Academic Medical Center, Amsterdam, Netherlands

  • 5. Department of Pulmonary Diseases, Medical Center, Institute for Cardiovascular Research, VU University Amsterdam, Amsterdam, Netherlands

  • 6. School of Life Sciences, The Medical School, MRC/Arthritis Research UK Centre for Musculoskeletal Ageing Research, Queen's Medical Centre, Nottingham, United Kingdom

Abstract

Heart rate (HR) has an impact on the central blood pressure (BP) wave shape and is related to pulse wave velocity and therefore to timing and duration of systole and diastole. This study tested the hypothesis that in healthy subjects both in rest and during sympathetic stimulation the relation between HR and pulse pressure (PP) is described by a linear effect model. Forty-four healthy volunteers were subjected to sympathetic stimulation by continuous lower body negative pressure (LBNP) until the onset of pre-syncopal symptoms. Changes in PP and HR were tracked non-invasively and modeled by linear mixed effect (LME) models. The dataset was split into two groups: the first was used for creating a model and the second for its evaluation. Models were created on the data obtained during LBNP. Model performance was expressed as absolute median error (1st; 3rd quantiles) and bias with limits of agreement (LOA) between modeled and measured PP. From rest to sympathetic stimulation, mean BP was maintained while HR increased (~30%) and PP decreased gradually (~20%). During baseline, PP could be modeled with an absolute error of 6 (4; 10) mm Hg and geometric mean ratio of the bias was 0.97 (LOA: 0.8–1.1). During LBNP, absolute median model error was 5 (4; 8) mmHg with geometric mean ratio 1.02 (LOA: 0.8–1.3). In conclusion, both during rest and during sustained sympathetic outflow induced by progressive central hypovolemia, a LME model of HR provides for an estimate of PP in healthy young adults.

Introduction

In the resting condition an elevated arterial pulse pressure (PP), the pulsatile component of blood pressure (BP), usually reflects decreased arterial compliance specifically in the elderly and is then associated with multiple adverse cardiovascular outcomes. In contrast, when healthy subjects exercise PP increases by the combined effects of an increase in systolic pressure concomitant to the elevated cardiac output (CO) and a reduction in diastolic pressure related to the vasodilatation in the exercising muscles (Lewis et al., 1983; Kim et al., 2015). PP provides prognostic utility beyond that of mean arterial pressure (MAP) (Selvaraj et al., 2016) and respiratory variations in PP relate to the magnitude of the central blood volume or left ventricular preload (Michard, 2005; Bronzwaer et al., 2015). However tracking PP requires a continuous BP signal either through arterial cannulation or through non-invasive BP measurement by plethysmography (Martina et al., 2012).

The duration of the cardiac cycle determines the length of diastole and influences the shape of the arterial pressure waveform (Wilkinson et al., 2000; Lantelme et al., 2002; Albaladejo et al., 2004; Haesler et al., 2004; Westerhof et al., 2008; Mackenzie et al., 2009; Benetos et al., 2010; Westerhof and Westerhof, 2013; Rimoldi et al., 2016). Recently, studies in both animals and humans using pacing or a selective negative chronotropic agent alleged evidence for an inverse relationship between PP and heart rate (HR) (Lantelme et al., 2002; Albaladejo et al., 2004; Haesler et al., 2004; Rimoldi et al., 2016). A lower HR prolongates diastole more than systole, widening PP (Figure 1; Folkow and Ely, 1998).

Figure 1

This study tested the hypothesis that in healthy subjects both in rest and during sympathetic stimulation the relationship between HR and PP can be described by a linear mixed effect (LME) model. To that purpose we tested this in young healthy adults by validating the resulting model on measured PP. Changes in HR and PP were introduced by sympathetic stimulation through induction of progressive central hypovolemia by lower body negative pressure (LBNP).

Materials and methods

This study was carried out in accordance with the recommendations of Academic Medical Centre Amsterdam medical ethical committee with written informed consent from all subjects. All subjects gave written informed consent in accordance with the Declaration of Helsinki. The protocol was approved by the Academic Medical Centre Amsterdam medical ethical committee (Study no. #2014_310).

Subjects

Forty-four healthy, non-smoking volunteers (21 females) who performed regular exercise and that did not use cardiovascular medication participated in the study (age: 24, standard deviation (SD) 4 years; height: 177, SD 10 cm; weight: 73, SD 11 kg). Exclusion criteria were a medical history of cardio- and/or cerebrovascular disease, neurological disorders, diabetes mellitus, regular fainting and the use of medication. Prior to the experiment subjects abstained from heavy exercise, alcohol and caffeinated beverages for at least 12 h.

Instrumentation

Continuous beat-to-beat BP was measured non-invasively using finger plethysmography (Nexfin, Edwards Lifesciences, Irvine, CA, USA; Martina et al., 2012). An appropriately sized finger cuff was applied to the mid-phalanx of the left hand. The hand was maintained at heart level. PP was defined as the difference between systolic and diastolic arterial pressure (SAP and DAP) and HR was defined as the inverse of the interbeat interval. MAP was the mean pressure over one BP pressure wave. Stroke volume (SV) was determined from the arterial pressure pulse wave by Nexfin CO-trek. Nexfin CO-trek readings are not different from a thermodilution estimate of CO for both invasive and non-invasive arterial pressure inputs, nor during upright exercise when compared to inert gas rebreathing (Bogert et al., 2010; Bartels et al., 2011) CO was SV multiplied by HR, and total peripheral resistance the ratio of MAP to CO.

Protocol

Following instrumentation, the lower part of the body was positioned inside a LBNP box (Dr. Kaiser Medizintechnik, Bad Hersfeld, Germany) and sealed at the level of the iliac crest (Goswami et al., 2009). The LBNP box was equipped with a saddle for subjects to sit on and to prevent leg muscle pump activation during the application of the sub-atmospheric pressure. Following 30 min of supine rest, continuous negative pressure (50 mmHg below atmospheric pressure) was applied to the lower body in one single step. The pressure inside the box was manually controlled and established within 20 s.

Monitoring of progressive central hypovolemia

Subjects were instructed to minimize movement and maintain their spontaneous breathing frequency and depth. Breathing frequency and end-tidal CO2 partial pressure were continuously monitored, verifying that end-tidal CO2 did not change significantly during the trial. An investigator experienced in human studies who was unoccupied by other experimental obligations monitored the subjects' well-being. LBNP was terminated either on request, at onset of (pre-) syncopal symptoms or after 30 min. Pre-syncopal symptoms were defined as one or more of the following criteria: systolic arterial pressure below 80 mmHg, or a rapid drop in BP (Δsystolic pressure ≥25 mmHg/min, Δdiastolic arterial pressure ≥15 mmHg/min), a drop in HR of ≥15 bpm, and/or sweating, light-headedness, nausea, vision alterations, skin pallor or a heat sensation.

Analysis

Data collected during the final 10 min of supine rest preceding onset of LBNP was averaged and defined as baseline. Data for each minute during LBNP was averaged and served as model input and output. We constructed LME models describing PP in relation to explanatory variable HR (fixed effect). Subject specific variables (random effects) were included to correct for, subject dependency and the expected variation in HR slope. LME models were computed in R (The R Project, The R Foundation for Statistical Computing, Vienna, Austria) (R Core Team, 2014) using the NLME library (Pinheiro et al., 2014). We used a crossover design to test model performance. The dataset was split into two groups (A and B). Initially, the data of group A served as model input and the data of group B was used to assess the performance of the acquired model. Then the process was interchanged: the data of group B was used to build a model and data of group A to test it (Figure 2). Absolute model errors determined during both baseline and LBNP were assessed per heartbeat. Median errors from all subjects following completion of the interchanging datasets are reported. Except for the modeling all data processing and statistics were performed in Matlab (Matlab 2007b, The MathWorks Inc., Natick, MA, USA).

Figure 2

Calibration

For the estimation of systolic and diastolic pressure the model was calibrated every 5 min to the 10 beat average of the non-invasive BP monitor to emulate an emergency setting in our hospital first aid department where on a routine basis only intermittent oscillometric BP is available.

Statistics

A rule of thumb for regression models requires 10 data samples for each included model parameter. Model performance is expressed as absolute median error, bias (mean of differences) and limit of agreement (LOA) (bias ± 1.96 SD) between measured and actual PP. In the case of normally distributed errors, bias and LOA are reported as geometric mean of the ratio between the two parameters. In the case of non-normally distributed model errors a logarithmic transformation was performed on the data before computing bias and LOA followed by a transformation back to get the geometric means ratio and its LOA (Bland and Altman, 1999). Data is reported as means and SD in the case of normally distributed parameters, and as median [1st; 3rd quantile] for parameters that were not distributed normally.

Results

Data of 3 subjects was excluded because of artifacts or noise in the measured signals, leaving data from 41 subjects available for analysis.

LBNP induced a rapid decline in SV (~25%) and PP (~15%) accompanied by an immediate ~30% increase in HR (Figure 3). Mean BP was maintained whereas systolic pressure declined ~10% and total peripheral resistance increased ~20%. LBNP was terminated in 37 out of 44 subjects because of pre-syncopal symptoms. Mean time until pre-syncope was 837 (SD 368) s; 7 subjects completed the full 30 min of LBNP. The relationships of HR and the BP parameters during baseline and LBNP (SAP, DAP, MAP and PP) are shown in Figure 4.

Figure 3

Figure 4

Model validation

The interchanging of datasets resulted in two equations for the model:

with HR in beats per minute and PP in mmHg. The distribution of the model input for HR ranged from 58 (SD 9) to 98 (SD 15) bpm. Model within group residuals were 9.0; and 10.3 for group A and B respectively.

Absolute model errors were 6.0 [3.9; 9.8] and 4.9 [3.8; 7.6] mmHg (Figure 5) during baseline and LBNP respectively. Model errors were not normally distributed. Geometric mean ratio of the bias was 0.97 with LOA 0.81–1.13 and 1.02 with LOA 0.77–1.27 during baseline and LBNP respectively.

Figure 5

Calibration of the model to intermittent BP further reduced estimated PP errors to: 2 [2–4] and 3 [2–4] mmHg during rest and LBNP respectively. Errors of systolic and diastolic pressures were normally distributed (Table 1).

Table 1

BaselineLBNP
BiasLimit of agreementBiasLimit of agreement
Systole0.71 [0.3–1.2]12.39 [11.5–13.2]1.66 [1.1–2.2]15.79 [14.8–16.8]
Diastole0.34 [0.1–0.6]9.03 [8.4–9.7]1.47 [1.1–13.9]14.76 [14.0–15.5]

Mean bias, limit of agreement of blood pressure estimation during baseline and lower body negative pressure (LBNP).

Numbers reflect mean and 95% confidence intervals in mmHg.

A concordance figure is shown in Figure 6. Mean degree to the line of identity was −5.5 CI 95% [−0.13 to −10.8] degrees. All but one sample fell within the range between −45 and −45 degrees. The sector holding 95% of the samples is ±30 degrees.

Figure 6

Discussion

The novel finding of this study is that in a setting of a sustained increase in sympathetic outflow by LBNP PP can be estimated from a LME model based on HR. The implication is that in healthy subjects PP can be tracked over time from HR without the requirement of recording continuous (non-)invasive BP. The data indicates that such a model provides an acceptable estimate of PP when venous return becomes reduced with decreasing cardiac volume and filling pressures and enhanced peripheral vascular resistance.

The LBNP procedure was terminated as soon as a subject experienced pre-syncopal symptoms, and the LME models are thus based on a reducing number of samples per passing minute. A merit of LME models is that they allow for such repeated observations and are applicable to datasets with missing data and/or small sample size (Verbeke and Molenberghs, 2000; Gueorguieva and Krystal, 2004; Torng et al., 2007; Pan et al., 2012). Related to the linearity of the equation, our model can only describe the response as described here and not when the relationship between PP and HR reverses, which may occur during pre-syncope where regularly PP and HR decline rapidly. Since PP is inversely modeled to HR (Equation 1), a reduction in HR will incorrectly predict an increase of PP. A restriction of linear models is that they cannot describe such complexity and therefore become unreliable under conditions where the PP—HR relationship is not in agreement with the model's assumptions, i.e., is an inverse linear one.

Limitations

By design, all subjects were young, healthy individuals, which restrains us from extrapolating the data to aging patients with cardiovascular disease. The model was tested for a limited range of HRs during rest and LBNP and it is unlikely that the model maintains reported performance far beyond the reaches of the used range. The modeled PP (Figure 5B) has difficulty in predicting PP at the start of the LBNP protocol. Due to the almost stepwise fashion in which PP and SV reduce in response to LBNP, the model inherently cannot describe PP accurately at this early stage. Calculating a mean value during such a rapid change is invalid due to the non-normally nature of PP during this phase. This increases estimation error for the initial segment. In a real-life clinical setting, the occurrence of such a rapid drop in blood volume is unlikely.

Clinical perspective

First line monitoring of patients presenting with hemorrhage includes measuring HR, arterial oxygen saturation and non-invasive intermittent oscillometric blood pressure (NIBP). However, none of these represent biomarkers highly sensitive to the detection of a blood volume deficit since during the initial phase of hypovolemic shock mean BP is maintained by a baroreflex mediated increment in HR and total peripheral resistance (Grant and Reeve, 1941; Barcroft et al., 1944; McMichael, 1944; Ryan et al., 2012; Secher and Van Lieshout, 2016). In contrast, PP decreases progressively during hypovolemic shock and rather than mean BP reflects central blood volume due to its relation to SV (Convertino et al., 2006; Bighamian and Hahn, 2014). Since PP is an important biomarker for changing volume state, application of the reported model could assist in the monitoring of patients at risk for blood loss or development of hypovolemia. It is the rate of change (or trend) noticeable in HR and PP rather than their absolute values that contain the dynamic information essential for clinicians to decide whether the cardiovascular system is in steady-state or is still subject to change. PP is more closely related to flow parameters such as SV where a reduction in PP strongly suggests a decline in SV. In general, BP is not sensitive for a reduction in flow, as illustrated in Figure 3: PP, SV and HR all change during LBNP, whereas MAP is still between 95 and 100% of its initial value.

The presented model does not require additional devices or measurements to function and can be used whenever HR is available, e.g., from electrocardiography or pulse oximetry. Further we demonstrated that the model can upgrade intermittent oscillometric BP to a continuous tracking device of systolic and diastolic BP by a 5 min interval calibration.

In conclusion, in healthy young adults who progress from a resting situation to a situation of sympathetic activation by progressive central hypovolemia PP and its trend can be estimated from HR.

Statements

Author contributions

Conception and experimental design: BS, BW, NS-W, JL, and WS; Data acquisition: BS and WS; Analysis: BS; Figure preparation: BS and JL Manuscript editing: BW, NS-W, WS, and JL.

Funding

Supported by an educational grant number Edwards Lifesciences: 2010B0797.

Conflict of interest

BW previously worked for Edwards Lifesciences Corp. They, however, had no say in any of the data or work presented. The other authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  • 1

    AlbaladejoP.ChallandeP.KakouA.BenetosA.LabatC.LouisH.et al. (2004). Selective reduction of heart rate by ivabradine: effect on the visco-elastic arterial properties in rats. J. Hypertens.22, 17391745. 10.1097/00004872-200409000-00018

  • 2

    BarcroftH.EdholmO. G.McMichaelJ.Sharpey-SchaferE. P. (1944). Posthaemorrhagic fainting. Study by cardiac output and forearm flow. Lancet1, 489491.

  • 3

    BartelsS. A.StokW. J.BezemerR.BoksemR. J.van GoudoeverJ.CherpanathT. G.et al. (2011). Noninvasive cardiac output monitoring during exercise testing: nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis. J. Clin. Monit. Comput.25, 315321. 10.1007/s10877-011-9310-4

  • 4

    BenetosA.ThomasF.JolyL.BlacherJ.PannierB.LabatC.et al. (2010). Pulse pressure amplification a mechanical biomarker of cardiovascular risk. J. Am. Coll. Cardiol.55, 10321037. 10.1016/j.jacc.2009.09.061

  • 5

    BighamianR.HahnJ. O. (2014). Relationship between stroke volume and pulse pressure during blood volume perturbation: a mathematical analysis. Biomed. Res. Int.2014:459269. 10.1155/2014/459269

  • 6

    BlandJ. M.AltmanD. G. (1999). Measuring agreement in method comparison studies. Stat. Methods Med. Res.8, 135160. 10.1177/096228029900800204

  • 7

    BogertL. W.WesselingK. H.SchraaO.Van LieshoutE. J.de MolB. A.van GoudoeverJ.et al. (2010). Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia65, 11191125. 10.1111/j.1365-2044.2010.06511.x

  • 8

    BronzwaerA. S.OuweneelD. M.StokW. J.WesterhofB. E.van LieshoutJ. J. (2015). Arterial pressure variation as a biomarker of preload dependency in spontaneously breathing subjects - a proof of principle. PLoS ONE10:e0137364. 10.1371/journal.pone.0137364

  • 9

    ConvertinoV. A.CookeW. H.HolcombJ. B. (2006). Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia. J. Trauma61, 629634. 10.1097/01.ta.0000196663.34175.33

  • 10

    CritchleyL. A.YangX. X.LeeA. (2011). Assessment of trending ability of cardiac output monitors by polar plot methodology. J. Cardiothorac. Vasc. Anesth.25, 536546. 10.1053/j.jvca.2011.01.003

  • 11

    FolkowB.ElyD. (1998). Importance of the blood pressure-heart rate relationship. Blood Press7, 133138. 10.1080/080370598437321

  • 12

    GoswamiN.GrasserE.RoesslerA.SchneditzD.Hinghofer-SzalkayH. (2009). The cardiovascular response to lower body negative pressure in humans depends on seal location. Physiol. Res.58, 311318.

  • 13

    GrantR. T.ReeveE. B. (1941). Clinical observations on air-raid casualties. Br. Med. J.2, 293297.

  • 14

    GueorguievaR.KrystalJ. H. (2004). Move over anova: progress in analyzing repeated-measures data andits reflection in papers published in the archives of general psychiatry. Arch. Gen. Psychiatry61, 310317. 10.1001/archpsyc.61.3.310

  • 15

    HaeslerE.LyonX.PruvotE.KappenbergerL.HayozD. (2004). Confounding effects of heart rate on pulse wave velocity in paced patients with a low degree of atherosclerosis. J. Hypertens.22, 13171322. 10.1097/01.hjh.0000125447.28861.18

  • 16

    KimY. S.SeifertT.BrassardP.RasmussenP.VaagA.NielsenH. B.et al. (2015). Impaired cerebral blood flow and oxygenation during exercise in type 2 diabetic patients. Physiol. Rep.3:e12430. 10.14814/phy2.12430

  • 17

    LantelmeP.MestreC.LievreM.GressardA.MilonH. (2002). Heart rate: an important confounder of pulse wave velocity assessment. Hypertension39, 10831087. 10.1161/01.HYP.0000019132.41066.95

  • 18

    LewisS. F.TaylorW. F.GrahamR. M.PettingerW. A.SchutteJ. E.BlomqvistC. G. (1983). Cardiovascular responses to exercise as functions of absolute and relative work load. J. Appl. Physiol. Respir. Environ. Exerc. Physiol.54, 13141323. 10.1152/jappl.1983.54.5.1314

  • 19

    MackenzieI. S.McEnieryC. M.DhakamZ.BrownM. J.CockcroftJ. R.WilkinsonI. B. (2009). Comparison of the effects of antihypertensive agents on central blood pressure and arterial stiffness in isolated systolic hypertension. Hypertension54, 409413. 10.1161/HYPERTENSIONAHA.109.133801

  • 20

    MartinaJ. R.WesterhofB. E.van GoudoeverJ.de BeaumontE. M.TruijenJ.KimY. S.et al. (2012). Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology116, 10921103. 10.1097/ALN.0b013e31824f94ed

  • 21

    McMichaelJ. (1944). Clinical aspects of shock. J. Am. Med. Assoc.124, 275281. 10.1001/jama.1944.02850050007003

  • 22

    MichardF. (2005). Changes in arterial pressure during mechanical ventilation. Anesthesiology103, 419428. 10.1097/00000542-200508000-00026

  • 23

    PanA. W.ChenY. L.ChungL. I.WangJ. D.ChenT. J.HsiungP. C. (2012). A longitudinal study of the predictors of quality of life in patients with major depressive disorder utilizing a linear mixed effect model. Psychiatry Res.198, 412419. 10.1016/j.psychres.2012.02.001

  • 24

    PinheiroJ. B. D.DebRoyS.SarkarD.R Core Team (2014). nlme: Linear and Nonlinear Mixed Effects Models. R package version 3.1-117.

  • 25

    R Core Team (2014). R: A Language and Environment for Statistical Computing.R Foundation for Statistical Computing.

  • 26

    RimoldiS. F.MesserliF. H.CernyD.GloeklerS.TraupeT.LaurentS.et al. (2016). Selective heart rate reduction with ivabradine increases central blood pressure in stable coronary artery disease. Hypertension67, 12051210. 10.1161/HYPERTENSIONAHA.116.07250

  • 27

    RyanK. L.RickardsC. A.Hinojosa-LabordeC.CookeW. H.ConvertinoV. A. (2012). Sympathetic responses to central hypovolemia: new insights from microneurographic recordings. Front. Physiol.3:110. 10.3389/fphys.2012.00110

  • 28

    SecherN. H.Van LieshoutJ. J. (2016). Hypovolemic shock, in Clinical Fluid Therapy in the Perioperative Setting, 2nd Edn., ed HahnR. G. (Cambridge: Cambridge University Press), 222231.

  • 29

    SelvarajS.StegP. G.ElbezY.SorbetsE.FeldmanL. J.EagleK. A.et al. (2016). Pulse pressure and risk for cardiovascular events in patients with atherothrombosis: from the REACH registry. J. Am. Coll. Cardiol.67, 392403. 10.1016/j.jacc.2015.10.084

  • 30

    TorngP. L.ChangW. C.HwangJ. S.HsuW. C.WangJ. D.HuangS. C.et al. (2007). Health-related quality of life after laparoscopically assisted vaginal hysterectomy: is uterine weight a major factor?Qual. Life Res.16, 227237. 10.1007/s11136-006-9123-y

  • 31

    VerbekeG.MolenberghsG. (2000). Linear Mixed Models for Longitudinal Data. New York, NY: Springer-Verlag.

  • 32

    WesterhofB. E.van den WijngaardJ. P.MurgoJ. P.WesterhofN. (2008). Location of a reflection site is elusive: consequences for the calculation of aortic pulse wave velocity. Hypertension52, 478483. 10.1161/HYPERTENSIONAHA.108.116525

  • 33

    WesterhofN.WesterhofB. E. (2013). Forward and backward pressure waves in the arterial system do represent reality. J. Physiol.591, 11671169. 10.1113/jphysiol.2012.249763

  • 34

    WilkinsonI. B.MacCallumH.FlintL.CockcroftJ. R.NewbyD. E.WebbD. J. (2000). The influence of heart rate on augmentation index and central arterial pressure in humans. J. Physiol.525, 263270. 10.1111/j.1469-7793.2000.t01-1-00263.x

Summary

Keywords

heart rate, linear mixed effect models, lower body negative pressure, pulse pressure, sympathetic stimulation

Citation

van Der Ster BJP, Sperna Weiland NH, Westerhof BE, Stok WJ and van Lieshout JJ (2018) Modeling Arterial Pulse Pressure From Heart Rate During Sympathetic Activation by Progressive Central Hypovolemia. Front. Physiol. 9:353. doi: 10.3389/fphys.2018.00353

Received

04 October 2017

Accepted

20 March 2018

Published

09 April 2018

Volume

9 - 2018

Edited by

Heikki Olavi Tikkanen, University of Helsinki, Finland

Reviewed by

Antti M. Kiviniemi, University of Oulu, Finland; Ilkka H. A. Heinonen, University of Turku, Finland

Updates

Copyright

*Correspondence: Johannes J. Van Lieshout

This article was submitted to Clinical and Translational Physiology, a section of the journal Frontiers in Physiology

†Björn J. P. Van Der Ster orcid.org/0000-0001-5190-5721

†Johannes J. Van Lieshout orcid.org/0000-0002-3646-2122

†Berend E. Westerhof orcid.org/0000-0003-4753-2461

†Nicolaas H. Sperna Weiland orcid.org/0000-0003-1305-1846

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics