VALIDITY AND RELIABILITY OF A PROTOCOL OF THE STOMATOGNATHIC AND POSTURAL SYSTEM EVALUATION FOR OBSTRUCTIVE SLEEP APNEA: A CROSS-SECTIONAL STUDY
Provisionally accepted- 1Virgin of Light Hospital, Cuenca, Spain
- 2Universidad de Castilla-La Mancha - Campus de Cuenca, Cuenca, Spain
- 3Universitat de Valencia, Valencia, Spain
- 4Universidad de Castilla-La Mancha - Campus de Toledo, Toledo, Spain
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Introduction: Myofunctional therapy has been used for years as an intervention with high effectiveness in cases of Obstructive Sleep Apnea (OSA). Until now, little importance has been given to postural attitude or morphotype, even though these can modify the state in which we find the musculature and fascial system of the entire stomatognathic system. The objective is to analyse the validity and reliability of a stomatognathic and postural systems assessment protocol for patients with OSA. Methods: This is a cross-sectional study that uses new observational and measurement parameters (the postural attitude or morphotype, the position of the hyoid bone, potential temporomandibular joint disorders and mobility of the spheno-basilar joint), were assessed in 105 adult subjects presenting with symptoms associated with OSA. All subjects were evaluated using the same guidelines and standardized tests. Participants ranged in age from 23 to 83 years and volunteered to take part in the study. The assessment followed a protocol encompassing two main components: (A) postural analysis , (B) specific evaluation of the stomatognathic system. All measurements were conducted by the same examiner. Results: Criterion validity was assessed using two Spearman correlation tests. The first examined the correlation between the final protocol score and the apnoea–hypopnoea index (AHI), yielding a value of 0.082. The second analysis assessed the correlation between the diagnostic results from sections A and B of the protocol, with correlation coefficients of 0.824 and 0.907 respectively. Concurrent validity was evaluated using Spearman correlation between the final protocol score and several variables: apnoea–hypopnoea index, Epworth Sleepiness Scale, physical activity, waist circumference, and neck circumference. All correlations were statistically significant (p<0.01; p<0.05). An ANCOVA was conducted to examine mean differences in variables across categories of the final protocol score, controlling for age and sex. Internal consistency of the scale was assessed using Cronbach’s alpha, which yielded a coefficient of 0.926. Reproducibility of the protocol was evaluated using the standardised intraclass correlation coefficient (ICC). Conclusions: The specific protocol for the evaluation of the stomatognathic and postural system for OSA (SPOSAP) is a valid and reliable instrument for the screening of the pathology. .
Keywords: obstructive sleep apnea, Myofunctional Therapy, Sleep Apnea, Postural reeducation, Stomatognathic System, Oropharyngeal exercises
Received: 18 Jun 2025; Accepted: 11 Aug 2025.
Copyright: © 2025 Guijarro-Herraiz, Arias Palencia, Mayordomo, Palomo-Carrión and Notario Pacheco. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Natalia Mª Arias Palencia, Universidad de Castilla-La Mancha - Campus de Cuenca, Cuenca, Spain
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.