Skip to main content

ORIGINAL RESEARCH article

Front. Med. Technol., 11 November 2021
Sec. Diagnostic and Therapeutic Devices
Volume 3 - 2021 | https://doi.org/10.3389/fmedt.2021.780090

Professionals' Views and Experiences of Using Rehabilitation Robotics With Stroke Survivors: A Mixed Methods Survey

  • 1Department of Mechanical, Aerospace and Civil Engineering, School of Engineering, University of Manchester, Manchester, United Kingdom
  • 2Division of Nursing, Midwifery and Social Work, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, United Kingdom

Objective: To understand the reason for low implementation of clinical and home-based rehabilitation robots and their potential.

Design: Online questionnaire (November 2020 and February 2021).

Subjects: A total of 100 professionals in stroke rehabilitation area were involved (Physiotherapists n = 62, Occupation therapists n = 35).

Interventions: Not applicable.

Main Measures: Descriptive statistics and thematic content analysis were used to analyze the responses: 1. Participants' details, 2. Professionals' views and experience of using clinical rehabilitation robots, 3. Professionals' expectation and concerns of using home-based rehabilitation robots.

Results: Of 100 responses, 37 had experience of rehabilitation robots. Professionals reported that patients enjoyed using them and they increased accessibility, autonomy, and convenience especially when used at home. The main emergent themes were: “aims and objectives for rehabilitation robotics,” “requirements” (functional, software, and safety), “cost,” “patient factors” (contraindications, cautions, and concerns), and “staff issues” (concerns and benefits). The main benefits of rehabilitation robots were that they provided greater choice for therapy, increased the amount/intensity of treatment, and greater motivation to practice. Professionals perceived logistical issues (ease of use, transport, and storage), cost and limited adaptability to patients' needs to be significant barriers to tier use, whilst acknowledging they can reduce staff workload to a certain extent.

Conclusion: The main reported benefit of rehabilitation robots were they increased the amount of therapy and practice after stroke. Ease of use and adaptability are the key requirements. High cost and staffing resources were the main barriers.

Introduction

Approximately two-thirds of stroke survivors are left with some degree of residual disability, particularly in limitations of the activities of daily living and mobility (1, 2). Physical and occupational therapy is a key to the recovery of function (3). Effective rehabilitation requires high repetition task-oriented training, which while effective, can be labor intensive and time consuming for treating therapists (46). One way to address this problem is using rehabilitation robotic devices. Since the first clinical rehabilitation robot MIT-MANUS was adopted for upper limb rehabilitation, the rehabilitation robots started the era of rapid development (7). Additionally, multiple literature review papers have proved the effectiveness of robotic-assisted therapy (4, 810). Mehrholz's systematic review identified that the two main types of rehabilitation robot are end-effector and exoskeleton robot, the end effector provides one attachment point for the user, and the exoskeleton can align all the joints of the limb (11). There is good evidence that using rehabilitation robots in addition to usual therapy can improve recovery of motor impairments and functions in both clinical and home environments (7, 1220). Despite this, the take up of rehabilitation robots during stroke rehabilitation is low due to the high cost, the various settings of clinical practices, accessibility for patients, and other barriers (2123). The aim of this paper was to better understand the reasons for low levels of implementation and to inform future robot design to ensure they are feasible, safe, and acceptable for stroke survivors and professionals.

Methods

Study Design

In this mixed method study, an online questionnaire was devised by the authors and optimized with the support of the wider research team (see section Acknowledgment). It included three sections using a mixture of open and closed questions, the latter answered with Likert scales (Figure 1; Supplementary Material 1). The first covered the respondents' demographics, clinical experience and experience of using rehabilitation robots. The second concerned professionals' experience and views of using clinical rehabilitation robots, and the third was specifically about home-based rehabilitation robots. The questionnaire was distributed by email to the authors' clinical and relevant research networks and via social media between Novembers 2020 and February 2021 to health care professionals with current or previous experience of stroke rehabilitation (with or without use of rehabilitation robotics) in any clinical setting. A response indicated consent.

FIGURE 1
www.frontiersin.org

Figure 1. Illustration of study strategy.

All responses were anonymous and did not contain any sensitive data thus, according to the requirement for ethical approval of the authors' institution(s), it was not required.

All quantitative data were analyzed using IBM SPSS (Statistical Package for the Social Sciences) v25.0 (IBM SPSS Statistics, RRID:SCR_019096). Descriptive statistics were used to aggregate the collected data. Mann-Whitney and Kruskal-Wallis tests compared groups. We categorized groups based on following characteristics: (1) participants' occupation (OT, occupational therapists; PT, physiotherapists); (2) career stage (<1 year, 1–5 years, 6–10 years, and >10 years); and (3) rehabilitation robot type (end-effector and exoskeleton).

For the qualitative data, an inductive thematic content analysis was undertaken using the questions in the questionnaire as a framework (16). Firstly, the respondents' statements were downloaded unedited into Excel (Microsoft Excel, RRID:SCR_016137). Then two of the authors (LT.L and ST) independently developed a coding matrix to categorize the respondents' composite statements. Our coding was shared and revised until a consensus was reached. The resulting coding framework was member checked with two respondents in the questionnaire (who had made themselves known to us—Dr. Verity Longley and Dr. Nick Preston), both experienced stroke professionals. Examples of the coding are shown in the Supplementary Material 2.

Results

One hundred professionals responded to the survey (Table 1; Supplementary Material 3). Two-thirds were physiotherapists; one-third were occupational therapists, plus one doctor and two rehabilitation assistants. Most (71%) were from the UK, had more than 10 years of work experience (58%) and worked in the local public health system (National Health Service) (79%). Inpatient rehabilitation was the most common (78%) work environment.

TABLE 1
www.frontiersin.org

Table 1. Respondent characteristics.

Only 37% had experience of using rehabilitation robots, mainly in hospital and out-patient clinic environments with patients in the sub-acute stages of stroke recovery (1–3 months post stroke) (Table 2). Powered exoskeleton robots were the most commonly used type of device (Table 2). The most common dose of robotic therapy was a treatment session lasting 30–45 min, 3–5 times per week for 4–8 weeks. The most common aim of treatment for robot therapy was to increase function (89%) but increasing strength and range of movement were also frequent (84 and 76%, respectively). Respondents had used robots more frequently for upper limb rehabilitation (95%) than lower limb (25%), which tended to focus on training sagittal shoulder and elbow movements (76 and 70%, respectively) and grasp grip (51%). Approximately equal proportions of patients for whom the respondents would use a rehabilitation robot had mild, moderate or severe weakness but fewer had very severe weakness. There were no significant differences in the use of rehabilitation robotics between occupational and physiotherapists, between staff at different career stages, nor the type of robot they had used (p <0.05).

TABLE 2
www.frontiersin.org

Table 2. How rehabilitation robots were used in clinical practice.

Respondents with and without experience of using rehabilitation robot had similar views regarding the type of patient for whom they were suitable; patients with moderate or severe lower or upper limb weakness were considered the most suitable (Supplementary Material 4).

Five main themes emerged from the framework analysis: “aims and objectives for rehabilitation robotics,” “requirements” (functional, software, and safety), “cost,” “patient factors” (contraindications, cautions, and concerns), and “staff issues” (concerns and benefits). These are detailed in Figure 2; Tables 3, 4.

FIGURE 2
www.frontiersin.org

Figure 2. Identified themes from questionnaire data regarding rehabilitation robots in clinical and home-based settings.

TABLE 3
www.frontiersin.org

Table 3. The final coding framework.

TABLE 4
www.frontiersin.org

Table 4. Frequency of responses to each sub-theme in different groups of respondents.

Each theme is described, and the representative quotation for each theme is shown in Table 5.

TABLE 5
www.frontiersin.org

Table 5. Representative quotation from professionals.

Theme 1: Aims and Objectives of Stroke Rehabilitation Robots

Participants reported that the main objective for using robots in stroke rehabilitation was to increase the amount of therapy patients received. This was expressed in a variety of ways; the terms “therapy,” “practice,” and “movement,” were used interchangeably as was “intensity” and “amount.” This was important, as the amount of therapy is related to the degree of recovery. Additionally, using a rehabilitation robot was thought to improve patients' motivation and engagement with therapy as it was considered an enjoyable activity. An additional objective for some participants was that using the robot enabled the patient to practice movement independently or autonomously of the therapy. However, some respondents had concerns about patients using the robots without professional supervision.

In addition, improving function and functional carry over were also important considerations, although some noted that the transfer from practicing movements with the robot to functional activity in everyday life could not be assumed. Others focused on the potential impact on impairments such as strength and range of movement. A final objective was that robotic therapy was useful to broaden the range of therapy options available to patients, which was also reported as one of the biggest advantages of using rehabilitation robots.

Theme 2: Requirements

Respondents identified many features which were needed to ensure that a stroke rehabilitation robot was feasible and acceptable for use in clinical practice. These were categorized into functional, software, and safety requirements.

Functional Requirements

The participants most frequently noted that a rehabilitation robot needed to be user-friendly. It needed to be easy and intuitive to set up, administer, don and doff (put on and take off), maintain, transport, and store. The device needed to be useable as a game or to practice functional tasks/movements and be operable as either an active or an active-assisted device to eliminate the effects of gravity during three-dimensional movements. To achieve this, a robot needed to be highly adjustable to meet a wide range of patients' needs—in terms of size, level of assistance needed, cognitive demands of the games, and individual preferences. Furthermore, the appearance needed to be appealing so that it did not put patients off using it and it had to be comfortable to use.

Not only was ease of use important, but it also needed to be quick to set up, program, and “put away” as the time taken for these activities impacted on staff resources and ultimately the cost. Compatibility with other systems such as virtual reality systems or other gaming devices was also important.

Software Requirements

The software supporting the robot's function was considered as important as the physical device. Again this needed to be easy and intuitive to use and suitable for a wide range of needs in terms of patients' aims of treatment; level of ability, and preferences.

Participants with experience using rehabilitation robots reported that there was room for improvement with the games available. For example a greater choice and range of difficulty but also suitable for adults.

The software needed to provide feedback on usage and performance to patients and therapists to facilitate motivation and progress treatment. It was also important that the application settings, dose of use (duration, frequency, number of repetitions), and amount of assistance provided by the device were recorded and easily transferred to clinical notes. The need for data security to protect patient confidentiality was noted.

Safety Requirements

Safety is a paramount and non-negotiable issue for any clinical device, which was frequently raised by respondents. Their concerns and requirements went beyond the obvious need to ensure the robot did not make the patient move beyond their range of movement and was comfortable. The risk of pressure points on fragile skin or finger traps were raised, as was the need for the device to be easy to clean and to comply with infection control policies. Given the patients' movement limitations, an alarm system, emergency stop, auto shutdown, and simple/quick release mechanisms were needed to avoid incorrect or over use and to prevent secondary injury, especially for home or unsupervised use. Stability and reliability were also important issues, as was the restricting access to the settings of the robot.

Theme 3: Cost

The high cost of rehabilitation robots and difficulty persuading hospitals to commit funds to pay for them were major barriers to their implementation into practice in both clinical and home-based settings. The cost of current rehabilitation robotics varies from $75,000 to $350,000 without any hidden cost such as taxes, installation or training, maintenance, and shipment (24). According to the “World Health Organization Choosing Interventions that are Cost-Effective” project, if a health intervention costs <3 times of the national annual gross domestic product (GDP) per capita, it will be considered as cost-effective (25). In case of UK, a robotic-assisted therapy is considered cost-effective or low-cost if the total cost is < $120,852 (update by the World Bank in December 2020) (26).

Theme 4: Patient Factors

Participants raised many concerns and issues regarding the type of patients for whom robot therapy would not be suitable. This included people with non-motor stroke related impairments such as behavioral, cognitive, perceptual, communication, or visual difficulties which could make them unable to use or understand how to use the robot. However, one participant noted that using rehabilitation robots could be beneficial for some of these impairments, as well as motor problems, for example encouraging visual scanning and practicing memory and problem solving tasks. Further problems which could limit the patients' ability to engage with robot therapy or safety were pain, fatigue, skin integrity, spasticity, or limited range of movement, particularly fixed joint contractures and should be carefully considered before use. Co-morbidities such as fractures, other musculoskeletal problems, or epilepsy also needed to be borne in mind when considering whether robot therapy was suitable for a patient.

As well as patients' clinical condition, therapists also needed to consider the patients' and their families' willingness to try rehabilitation robots, particularly for home use. The “flip side” to this was concerns that patients could become “over-reliant” on the robots and disengage or refuse other aspects of therapy which may limit progress toward independent practice and activity in everyday life or could be a risk for overuse or secondary injuries.

Theme 5: Staff Issues

Participants highlighted the potential impact of rehabilitation robots on staff as well as patients. A common concern was that using rehabilitation robots to deliver greater amounts of therapy could replace, disempower, or deskill therapists. Respondents were careful to point out that robotic therapy should be an adjunct, but not a substitute to “traditional” care.

Other respondents raised concerns about the resources needed to deliver robotic therapy. As therapists' working days were already full, if they were to incorporate robotic therapy into practice, either more staff were needed or they needed to stop providing some other aspect of care.

While some participants were confident to delegate the supervision of robot rehabilitation to therapy assistants (unqualified staff), family members or, for patients to use the robots unsupervised, others felt that direct supervision from qualified staff was necessary. Furthermore, several pointed out that qualified staff's time was needed to prescribe and set up the robot, problem solve, and oversee progression whether the patient was supervised or not.

Time and staffing were not the only important resourcing issue. Staff also needed adequate training and on-going support to develop clinical skills to use the robots effectively in every-day practice. As many staff regularly change work areas (referred to as “rotation”), this input needed to be on-going to accommodate staff changes. All of which increased the cost of robotic therapy.

Finally, given the professional duty to provide evidence-based care, some respondents raised the limited evidence to support its use as a barrier to implementation.

Discussion

This research identified the benefits, requirements, concerns, and barriers to implementation of rehabilitation robots by analyzing professionals' experience and views of their use in both clinical and home-based environments. The majority (71%) of the survey responses were from UK and as such are representative of this country, it cannot be assumed that these results are necessarily representative of other geographical regions. Participants were generally positive about rehabilitation robots. Their biggest advantages was that they facilitated high repetition task-oriented training, which was consistent with the principle of efficient rehabilitation (2730). This was achieved not only by providing physical support to enable the patient to move the weak limb but also by increasing patients' motivation and engagement to practice tasks and/or play games, which are also important factors in effective rehabilitation (13). From a professional perspective, the most commonly reported benefit for staff was the potential to reduce their work load, while providing greater amounts of therapy, as the patient could practice moving using the robot unsupervised or with “light touch” supervision, especially when the robots were home-based. However, reduced workload, and therefore cost could not be assumed, as the purchase cost of rehabilitation robots were considered prohibitive by many. Further resources included staffing and training also needed to be taken into account.

Powered upper limb robots (whether exo-skeleton or end-effector) were the most commonly used rehabilitation robot in clinical practice. This may not only be because active robots can provide a wide range of support and functions, but also because upper limb robots are relatively small, which is more convenient, than lower limb robots.

Home-based rehabilitation robots were identified as having great potential to facilitate accessibility, autonomy, and increase choice for therapy. Home-based systems can be convenient for patients as they eliminate the need to travel for access and enable autonomous usage. Professionals would be more confident in prescribing home-based robot therapy with well-developed interaction systems, such as remote monitoring and supervision.

Our findings have provided a wealth of detail regarding professionals' requirements for stroke rehabilitation robots to be fit for purpose and to be adopted into practice. In addition to reducing the costs, rehabilitation robots need to be “user friendly,” safe, and suitable for a wide range of needs. All aspects of use needed to be quick, easy, intuitive, and adaptable. Safety is, of course, a non-negotiable issue especially if the robot is to be used unsupervised. Participants recognized that although there were few absolute contraindications, robots needed to be considered cautiously for people with non-motor stroke related impairments and co-morbidities which could limit their ability to understand or to use a robot safely. Furthermore, patients' preferences also need to be taken into account—not everyone wants to play games, or use technology. However, accommodating this range of needs is likely to increase costs. Alternatively if costs are minimized, then the range of users is likely to be limited. In reality, commercialization of rehabilitation robots needs to balance these competing demands with a priority to ease of use as the mismatch between the demands of operating devices and other aspects of clinical practice has rendered many promising health technologies unfit for purpose (3133). Future robot development work needs to consider these issues. Rather than focussing on progressing the sophistication and complexity of the technology, focussing on simpler technology and operation at lower cost may be key to successful implementation.

Study Limitations

The main limitations of this study include the convenience of the recruitment strategies, which may be biased toward professionals with positive views or experiences of using rehabilitation robots. Although we received responses from all over the world, most were from the UK. The findings may differ if census or probability style recruitment techniques were used or if participants from other countries were involved. However, we suggest that need for low cost, user-friendly, adaptable devices is probably universal. We have also, to date, only involved professionals. Stroke survivors and their carers/families may have other views, cautions or requirements. For the further research, the involvement of these important stakeholders should be considered.

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Author Contributions

LL, ST, and AW conceptualized the paper. LL and ST analyzed the collected data. All authors contributed to the evaluation study itself, the manuscript, and approved the final version of the manuscript.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Acknowledgments

The authors would like to thank all participants and people who helped us to send out the questionnaire. We thank our wider research team, especially Dr. Nick Preston, Dr. Ulrike Hammerbeck, and Dr. Verity Longley who helped us improve the questionnaire organization and development framework.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmedt.2021.780090/full#supplementary-material

References

1. Katan M, Luft A editors. Global burden of stroke. Semin Neurol. (2018) 38:208–211. doi: 10.1055/s-0038-1649503

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Rothwell PM, Coull AJ, Giles MF, Howard SC, Silver LE, Bull LM, et al. Change in stroke incidence, mortality, case-fatality, severity, and risk factors in Oxfordshire, UK from 1981 to 2004 (Oxford Vascular Study). Lancet. (2004) 363:1925–33. doi: 10.1016/S0140-6736(04)16405-2

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Díaz I, Gil JJ, Sánchez E. Lower-limb robotic rehabilitation: literature review and challenges. Journal of Robotics. (2011) 2011:759764. doi: 10.1155/2011/759764

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Veerbeek JM, Langbroek-Amersfoort AC, Van Wegen EE, Meskers CG, Kwakkel G. Effects of robot-assisted therapy for the upper limb after stroke: a systematic review and meta-analysis. Neurorehabil Neural Repair. (2017) 31:107–21. doi: 10.1177/1545968316666957

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Lohse KR, Hilderman CG, Cheung KL, Tatla S, Van der Loos HM. Virtual reality therapy for adults post-stroke: a systematic review and meta-analysis exploring virtual environments and commercial games in therapy. PLoS ONE. (2014) 9:e93318. doi: 10.1371/journal.pone.0093318

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Veerbeek JM, van Wegen E, van Peppen R, van der Wees PJ, Hendriks E, Rietberg M, et al. What is the evidence for physical therapy poststroke? A systematic review and meta-analysis. PLoS ONE. (2014) 9:e87987. doi: 10.1371/journal.pone.0087987

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Laut J, Porfiri M, Raghavan P. The present and future of robotic technology in rehabilitation. Curr Phys Med Rehabil Rep. (2016) 4:312–9. doi: 10.1007/s40141-016-0139-0

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Norouzi-Gheidari N, Archambault PS. Fung J. Effects of robot-assisted therapy on stroke rehabilitation in upper limbs: systematic review and meta-analysis of the literature. J Rehabil Res Dev. (2012) 49:479–96. doi: 10.1682/JRRD.2010.10.0210

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Mehrholz J, Pohl M, Platz T, Kugler J, Elsner B. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke. Cochrane Database Syst Rev. (2018) 9:CD006876-CD. doi: 10.1002/14651858.CD006876.pub5

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Bertani R, Melegari C, De Cola MC, Bramanti A, Bramanti P, Calabro RS. Effects of robot-assisted upper limb rehabilitation in stroke patients: a systematic review with meta-analysis. Neurol Sci. (2017) 38:1561–9. doi: 10.1007/s10072-017-2995-5

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Mehrholz J, Pohl M. Electromechanical-assisted gait training after stroke: a systematic review comparing end-effector and exoskeleton devices. J Rehabil Med. (2012) 44:193–9. doi: 10.2340/16501977-0943

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Van der Loos HFM, Reinkensmeyer DJ, Guglielmelli E. Rehabilitation and health care robotics. In: Siciliano B, Khatib O, editors. Springer Handbook of Robotics. Cham: Springer International Publishing (2016). p. 1685–728. doi: 10.1007/978-3-319-32552-1_64

CrossRef Full Text | Google Scholar

13. Metzger J-C, Lambercy O, Califfi A, Dinacci D, Petrillo C, Rossi P, et al. Assessment-driven selection and adaptation of exercise difficulty in robot-assisted therapy: a pilot study with a hand rehabilitation robot. J Neuroeng Rehabil. (2014) 11:154. doi: 10.1186/1743-0003-11-154

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Pellegrino G, Tomasevic L, Tombini M, Assenza G, Bravi M, Sterzi S, et al. Inter-hemispheric coupling changes associate with motor improvements after robotic stroke rehabilitation. Restor Neurol Neurosci. (2012) 30:497–510. doi: 10.3233/RNN-2012-120227

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Hesse S, Werner C, Pohl M, Rueckriem S, Mehrholz J, Lingnau ML. Computerized arm training improves the motor control of the severely affected arm after stroke. Stroke. (2005) 36:1960–6. doi: 10.1161/01.STR.0000177865.37334.ce

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Sivan M, Gallagher J, Makower S, Keeling D, Bhakta B, O'Connor RJ, et al. Home-based Computer Assisted Arm Rehabilitation (hCAAR) robotic device for upper limb exercise after stroke: results of a feasibility study in home setting. J Neuroeng Rehabil. (2014) 11:163. doi: 10.1186/1743-0003-11-163

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Ates S, Mora-Moreno I, Wessels M, Stienen AHA. Combined active wrist and hand orthosis for home use: lessons learned. In: Yu HY, Braun D, Campolo D, editors. Proceedings of the IEEE/RAS-EMBS International Conference on Rehabilitation Robotics (ICORR). Pisa (2015). p. 398–403. doi: 10.1109/ICORR.2015.7281232

CrossRef Full Text | Google Scholar

18. Ates S, Haarman CJW, Stienen AHA, SCRIPT. passive orthosis: design of interactive hand and wrist exoskeleton for rehabilitation at home after stroke. Auton Robots. (2017) 41:711–23. doi: 10.1007/s10514-016-9589-6

CrossRef Full Text | Google Scholar

19. Ates S, Lobo-Prat J, Lammertse P, van der Kooij H, Stienen AH editors. SCRIPT passive orthosis: design and technical evaluation of the wrist and hand orthosis for rehabilitation training at home. In: 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR). Seattle, WA: IEEE (2013). doi: 10.1109/ICORR.2013.6650401

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Mehrholz J, Thomas S, Kugler J, Pohl M, Elsner B. Electromechanical-assisted training for walking after stroke. Cochrane Database Syst Rev. (2020) 10:CD006185. doi: 10.1002/14651858.CD006185.pub5

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Fong J, Crocher V, Klaic M, Davies K, Rowse A, Sutton E, et al. Promoting clinical best practice in a user-centred design study of an upper limb rehabilitation robot. Disabil Rehabil Assist Technol. (2020) 2020:1–8. doi: 10.1080/17483107.2020.1785567

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Standen P, Threapleton K, Connell L, Richardson A, Brown DJ, Battersby S, et al. Patients' use of a home-based virtual reality system to provide rehabilitation of the upper limb following stroke. Phys Ther. (2015) 95:350–9. doi: 10.2522/ptj.20130564

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Shirota C, Balasubramanian S, Melendez-Calderon A. Technology-aided assessments of sensorimotor function: current use, barriers and future directions in the view of different stakeholders. J Neuroeng Rehabil. (2019) 16:53. doi: 10.1186/s12984-019-0519-7

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Duret C, Grosmaire A-G, Krebs HI. Robot-assisted therapy in upper extremity hemiparesis: overview of an evidence-based approach. Front Neurol. (2019) 10:412. doi: 10.3389/fneur.2019.00412

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Demofonti A, Carpino G, Zollo L, Johnson MJ. Affordable robotics for upper limb stroke rehabilitation in developing countries: a systematic review. IEEE Trans Med Robot Bion. (2021) 3:11–20. doi: 10.1109/TMRB.2021.3054462

CrossRef Full Text | Google Scholar

26. Bank TW. GDP Per Capita (Current US$) - United Kingdom (2020). Available online at: https://data.worldbank.org/indicator/NY.GDP.PCAP.CD?locations=GB (accessed October 12, 2021)

27. Stinear CM, Lang CE, Zeiler S, Byblow WD. Advances and challenges in stroke rehabilitation. Lancet Neurol. (2020) 19:348–60. doi: 10.1016/S1474-4422(19)30415-6

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Langhorne P, Bernhardt J, Kwakkel G. Stroke rehabilitation. Lancet. (2011) 377:1693–702. doi: 10.1016/S0140-6736(11)60325-5

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Popescu D, Manta F, Rusu L, Avramescu TE, Zavaleanu M. Upper limb rehabilitation robotic system requirements analysis. In: Ferraresi C, Quaglia G, editors. Advances in Service and Industrial Robotics. RAAD 2017. Mechanisms and Machine Science, Vol 49. Cham: Springer (2018). p. 919–27. doi: 10.1007/978-3-319-61276-8_98

CrossRef Full Text | Google Scholar

30. Kyto M, Maye L, McGookin D, Assoc Comp M. Using both hands: tangibles for stroke rehabilitation in the home. In: CHI'19: Proceedings of the 2019 CHI Conference on Human Factors in Computing Systems. Glasgow (2019) 1–14. doi: 10.1145/3290605.3300612

CrossRef Full Text | Google Scholar

31. Organization WH. Medical Devices: Managing the Mismatch: An Outcome of the Priority Medical Devices Project. World Health Organization (2010).

Google Scholar

32. Bessler J, Prange-Lasonder GB, Schaake L, Saenz JF, Bidard C, Fassi I, et al. Safety assessment of rehabilitation robots: a review identifying safety skills and current knowledge gaps. Front Robot AI. (2021) 8:602878. doi: 10.3389/frobt.2021.602878

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Musselman KE, Shah M, Zariffa J. Rehabilitation technologies and interventions for individuals with spinal cord injury: translational potential of current trends. J Neuroeng Rehabil. (2018) 15:40. doi: 10.1186/s12984-018-0386-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: rehabilitation, robotics, home-based, clinical, stroke

Citation: Li L, Tyson S and Weightman A (2021) Professionals' Views and Experiences of Using Rehabilitation Robotics With Stroke Survivors: A Mixed Methods Survey. Front. Med. Technol. 3:780090. doi: 10.3389/fmedt.2021.780090

Received: 20 September 2021; Accepted: 22 October 2021;
Published: 11 November 2021.

Edited by:

Dinesh Kumar, RMIT University, Australia

Reviewed by:

Khashayar Khoshmanesh, RMIT University, Australia
Barbara Polus, RMIT University, Australia

Copyright © 2021 Li, Tyson and Weightman. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Andrew Weightman, andrew.weightman@manchester.ac.uk

Download