Objective: To examine the causes and factors that lead to high order aberration (HOA) during the treatment of myopia using small incision lenticule extraction (SMILE), as well as the differences between SMILE and other corneal refractive surgeries through a systematic review and meta-analysis.

Methods: A systematic search was conducted from January 2015 to February 2023 in Pubmed, Embase, Web of Science, and Google Scholar databases to gather relevant studies on SMILE and HOA. Studies meeting specific criteria were chosen, and clinical data was retrieved for analysis.

Results: This meta-analysis resulted in the inclusion of 19 studies involving 1,503 eyes. Pooled results showed significant induction of total HOA (tHOA, d = −0.21, p < 0.001), spherical aberration (SA, d = −0.11, p < 0.001) and coma aberration (CA, d = −0.18, p < 0.001) after SMILE compared to pre-SMILE, while no significant change in trefoil aberration (TA) was observed (d = −0.00, p = 0.91). There was a significantly lower induction of tHOA after SMILE compared to femtosecond laser-assisted in situ keratomileusis (FS-LASIK, d = 0.04, p < 0.001), and no significant difference was observed compared to wavefront aberration-guided (WFG) refractive surgery (d = 0.00, p = 0.75). There was also a significant association between different levels of myopia and astigmatism, duration of follow-up, lenticule thickness, and preoperative central corneal thickness (CCT) on the induction of tHOA after SMILE (p < 0.05), while the higher preoperative myopia group (sphere > -5D), lower preoperative astigmatism group (cylinder ≤ -1D), larger lenticule thickness group (lenticule thickness > 100 μm), shorter follow-up group (follow-up 1 month postoperatively) and the thicker CCT group (CCT > 550 μm) brought a significant induction of tHOA compared to the opposite comparison group (p < 0.001).

Conclusion: While SMILE can induce HOA significantly, it induces less HOA than FS-LASIK. Postoperative HOA following SMILE can be affected by factors such as myopia, astigmatism, lenticule thickness, CCT, and duration of follow-up. Future research should continue to explore techniques to decrease the induction of HOA by using this methodology.

Systematic review registration: https://www.crd.york.ac.uk/prospero/.

Introduction

Myopia is one of the most significant public health problems affecting eye health worldwide, especially among adolescents. The World Health Organization (WHO) reports that the overall prevalence of myopia in high-income countries in the Asia-Pacific area is 53.4% of the global population, with East Asia having a similar rate (1). The prevalence of myopia was growing, impacting the quality of life for many individuals. The development of corneal refractive surgeries was addressing this issue (2). Radial keratotomy (RK) was the first corneal refractive surgery developed to correct myopia. Subsequently, photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), laser-assisted subepithelial keratomileusis (LASEK), and small incision lenticule extraction (SMILE) were introduced as advancements in the field (3). SMILE, a type of corneal refractive surgery known for its low invasiveness, excellent accuracy, minimal complications, and reduced postoperative corneal irritation symptoms, has received increased attention in recent studies. Sekundo et al. (4) introduced it in 2011. Research on SMILE has shown that it demonstrates strong safety, effectiveness, predictability, and ocular surface stability after surgery. Additionally, it has a low occurrence of postoperative epithelial flap issues and dry eye (5).

Medically generated HOA can raise the likelihood of visual quality problems such as halos, glare, ghost, and reduced contrast sensitivity in corneal refractive surgery (6). Consequently, an increasing number of scholars are concentrating on the postoperative induction of HOA. Wu and Wang (7) discovered that both FS-LASIK and FLEx could cause irregularities in the shape of the corneal surface and a notable induction in postoperative corneal HOA. In contrast, Xia et al. (8) observed that total HOA (tHOA) and vertical coma aberration (CA) were notably elevated after SMILE compared to the preoperative period. Later, certain scholars “customized” the preoperative corneal wavefront aberration which achieved controllability of corneal HOA. The prior occurrence of HOA was eradicated and the development of new HOA was avoided (9). Despite the technical advantages, there is very conflicting data on whether personalized corneal refractive surgery results in decreased postoperative induction of HOA compared to SMILE procedures (10). Kwak et al. (11) discovered that SMILE does not cause spherical aberration (SA) in several types of HOA. However, Zhong et al. (12) observed a notable rise in both SA and CA following SMILE. Currently, SMILE and other corneal refractive surgeries can cause considerable HOA, but there is still uncertainty regarding the specific forms of HOA induced by SMILE and how it affects changes in HOA. Thus, examining, evaluating, and minimizing the occurrence of HOA has become a shared goal for patients and surgeons. This study aims to synthesize data on changes in HOA following SMILE and other corneal refractive surgeries using systematic review and meta-analysis. To examine the development of HOAs caused by SMILE and compare them with other types of corneal refractive surgeries. Finally examining the affecting aspects of HOA, to provide reference and help to alleviate HOA after SMILE.

Methods

A meta-analysis was conducted following the established procedures of the Meta-analysis of Observational Studies in Epidemiology (MOOSE) (13). The study adhered to the principles outlined in the Declaration of Helsinki and received approval from the Ethics Committee of Peking Union Medical College Hospital (14).

Search strategy

This study conducted a comprehensive review and meta-analysis of research on SMILE and HOA. Data were retrieved by searching Pubmed, Embase, Web of Science, and Google Scholar databases for all studies on SMILE and HOA published between January 2015 and February 2023, specifically in English. The English search terms used were “small incision lenticule extraction” or “small-incision lenticule extraction” or “SMILE” or “Smile” or “smile” and “high order aberration” or “higher-order aberration” or “high order aberrations” or “HOA” or “HOAs” or “hoa” or “aberration” (the retrieval of different types of HOAs has been included in the above comprehensive retrieval process). The search was conducted across all fields. Articles must be those recently published in the appropriate journal, including papers released online before the print version.

Three ophthalmologists (YiD, YuD and SY) independently conducted the literature screening process and each summarized the chosen papers. Then an experienced ophthalmologist evaluated the literature and identified relevant literature that met the screening criteria, which may be found in the next section on inclusion and exclusion criteria. The screening process is as follows: Literature was summarized and reviewed using Endnote x9 software, then assessed for relevance based on the abstract and title. The remaining literature was fully downloaded and then filtered based on specific inclusion and exclusion criteria to obtain the accessible data.

Inclusion and exclusion criteria

The study’s inclusion criteria were: (1) observational studies with specific preoperative and postoperative HOA data (retrospective or prospective cohort studies, which require sample selection without specific bias or intervention); (2) surgeries had to be SMILE, but could include other corneal refractive surgeries; (3) patients undergoing surgery had to be myopic with or without varying degrees of astigmatism; (4) articles had to include average, standard deviations, and sample sizes of HOA data that could be extracted or calculated; (5) HOA data had to include tHOA, and other HOAs like SA, CA, or trefoil aberration (TA) if possible; (6) Patients scheduled for surgery must not have any eye conditions other than myopia and should not experience any visual function issues before the operation. The study excluded research that: (1) studies without follow-up data; (2) articles categorized as “review,” “letter,” “commentary,” or “case report”; (3) studies that were published multiple times or used data from the same studies (only one was chosen); (4) studies with incomplete data.

Data extraction

The study extracted the fundamental data and HOA data from the final conforming literature. The data consisted of author, publication date, sample size, age, aberration analyzer, mean spherical, mean cylinder, scanned pupil diameter, and duration of follow-up. The main observations in this work focused on pre- and post-operative HOA, which included total pre- and post-operative HOA, SA, CA, and TA. The results are presented as the mean difference between these markers (mean ± standard deviation). We also gathered information about other corneal refractive surgeries in case the study involved comparing SMILE with them. We categorize these articles into several subgroups according to factors like spherical, cylinder, duration of follow-up, etc. We next analyze and compare the parameters that influence changes in HOA.

Quality assessment

We evaluated the quality of the retrospective observational studies included in this analysis using the Newcastle-Ottawa Scale (NOS). Each study’s risk of bias was assessed based on this scale, and the scores for each study were calculated and combined, with scores ranging from 0 (lowest quality) to 9 (highest quality) (15).

Sensitivity analysis and publication bias

A sensitivity analysis was conducted by performing a “leave-one-out” analysis to assess the robustness of the statistical model. This involved systematically removing each study included in the analysis to examine their impact on the overall pooled estimates. Publication bias was analyzed by Egger’s test (16) and Begg’s test (17) for the included studies, which were determined not to have substantial publication bias if the result was p > 0.05.

Statistical analysis

The study utilized RevMan v5.3 for meta-analysis and to create forest and funnel plots. We utilized I2 to assess the heterogeneity of the literature included, with a significance level of α = 0.1. Heterogeneity was assessed using the I2 statistic. If p ≥ 0.10 and I2 ≤ 50%, the studies were deemed homogeneous and a fixed-effects model was used for meta-analysis. Conversely, if p < 0.1 and I2 > 50%, heterogeneity was present, and a random-effects model was employed for meta-analysis. Due to differences in devices, evaluation methodologies, and algorithms among studies, variations in results are inevitable when measuring HOA. While it is challenging to directly compare various devices and algorithms at the individual level, it is still possible to derive HOA values at the group level, albeit the diversity of the research becomes more pronounced. The aberration analyzer utilized in the various investigations has been identified in Table 1. The final observation involves comparing the mean difference between the two groups, where statistical significance is determined by a p-value of less than 0.05.

Table 1
www.frontiersin.org

Table 1. Summary of basic information on SMILE and HOA related studies included in this study.

Results

Results of the screening and sensitivity analysis

A total of 842 articles were chosen from the designated search databases based on our search criteria. After eliminating 255 duplicate articles, the remaining 587 articles were initially evaluated based on their study content and focus using titles and abstracts (excluding irrelevant literature). Later, 116 articles were chosen based on the literature screening criteria outlined in the methodology section: Inclusion and Exclusion Criteria. Forty-four articles were not cohort studies; 27 articles did not have pre- or post-operative data; 12 articles did not randomize the surgical population; 10 articles did not include analysis of HOA; and 8 articles were omitted for other reasons. We evaluated the already identified literature and found 4 new articles from their reference sections and cited articles. Ultimately, 19 articles that satisfied our criteria were included in this meta-analysis (7, 8, 1012, 1831). Figure 1 displays a flow chart of the literature reviewed in this study. The sensitivity analysis results showed that both the Egger’s test (p = 0.178 to 1.000) and Begg’s test (p = 0.212 to 1.000) did not reveal any significant publication bias among the 19 included articles. The fundamental details and data from the 19 articles are outlined in Table 1, while the risk of bias and NOS scores for each study are displayed in Table 2.

Figure 1
www.frontiersin.org

Figure 1. Flow diagram of the literature search.

Table 2
www.frontiersin.org

Table 2. Bias risk assessment results and NOS score of included retrospective studies.

Changes in various HOAs after SMILE

Overall, the results of this meta-analysis showed a significant induction of tHOA (d = −0.21, 95%CI: −0.15 to −0.27, I2 = 97%, random effects model, p < 0.001) following SMILE in comparison to before the procedure. When examining each category of HOA individually, SA (d = −0.11, 95%CI: −0.07 to −0.14, I2 = 94%, random effects model, p < 0.001) and CA (d = −0.18, 95%CI: −0.12 to −0.23, I2 = 94%, random effects model, p < 0.001) were also significantly induced. TA was not substantially affected by SMILE (d = −0.00, 95%CI: −0.04 to 0.04, I2 = 95%, random effects model, p = 0.91). The detailed outcomes are displayed in Figures 2, 3 and Table 3.

Figure 2
www.frontiersin.org

Figure 2. Outcomes of SMILE induced HOAs (tHOA). SD, standard deviation; CI, confidence interval; df, degree(s) of freedom; I2, heterogeneity; Z, overall effect.

Figure 3
www.frontiersin.org

Figure 3. Outcomes of SMILE induced HOAs. (A) Spherical aberration introduced by SMILE; (B) coma aberration introduced by SMILE; (C) trefoil aberration introduced by SMILE. SD, standard deviation; CI, confidence interval; df, degree(s) of freedom; I2, heterogeneity; Z, overall effect.

Table 3
www.frontiersin.org

Table 3. Meta-analysis of HOA induction in SMILE and other corneal refractive surgeries.

Postoperative induction of HOA of SMILE versus FS-LASIK and wavefront aberration-guided surgery

The meta-analysis results indicate that SMILE and other corneal refractive surgeries lead to induced HOA compared to FS-LASIK. However, the analysis reveals a significant decrease in induced tHOA after SMILE compared to FS-LASIK (d = 0.04, 95%CI: 0.02 to 0.06, I2 = 52%, fixed-effect model, p < 0.001), while there was no significant difference in postoperative induction of tHOA between SMILE and wavefront aberration-guided (WFG) refractive surgery (d = 0.00, 95%CI: −0.01 to 0.02, I2 = 0%, fixed-effect model, p = 0.75). The precise outcomes are displayed in Figure 4 and Table 3.

Figure 4
www.frontiersin.org

Figure 4. Outcomes of comparison between SMILE and other keratorefractive surgeries. (A) SMILE vs. FS-LASIK; (B) SMILE vs. WFG-surgery. SD, standard deviation; Cl, confidence interval; df, degree(s) of freedom; l2, heterogeneity; Z, overall effect.

Factors affecting the change in HOA before and after SMILE

After consolidating the data from combining each study, we analyzed the indicators of myopia and astigmatism degree, duration of follow-up, lenticule thickness, and preoperative central corneal thickness (CCT), after which we divided these studies into two groups according to different indicators (whether sphere >-5D, whether cylinder >-1D, follow-up of 1 month and 6 months, whether the lenticule thickness was larger than 100 μm, and whether preoperative CCT was larger than 550 μm). The results showed that there was a significant induction of tHOA after SMILE compared to preoperative for all indicators under the grouping (p < 0.05). Analysis by t-test showed that the higher myopia group (sphere >-5D, d = −0.41, 95%CI: −0.30 to −0.52, I2 = 96%, random effects model, p < 0.001), the lower astigmatism group (cylinder ≤-1D, d = −0.30, 95%CI: −0.21 to −0.39, I2 = 96%, random effects model p < 0.001), the group with shorter follow-up (1 month, d = −0.24, 95%CI: −0.12 to −0.37, I2 = 97%, random effects model, p < 0.001), the group with greater lenticule thickness (lenticule thickness > 100 μm, d = −0.28, 95%CI: −0.06 to −0.50, I2 = 98%, random effects model, p = 0.01) and the thicker preoperative CCT group (preoperative CCT >550 μm, d = −0.25, 95%CI: −0.10 to −0.41, I2 = 98%, random effects model, p = 0.001) had significantly induced the postoperative tHOA introduction compared to the comparison group (p < 0.05). The precise outcomes are displayed in Figure 5.

Figure 5
www.frontiersin.org

Figure 5. Outcomes of the induction of HOAs by SMILE under different factor grouping. (A) The lower myopia (sphere≤-5D); (B) the higher myopia group (sphere>-5D); (C) the lower astigmatism group (cylinder≤-1D); (D) the higher astigmatism group (cylinder>-1D); (E) shorter follow-up group (1 month); (F) longer follow-up group (6 months); (G) thicker lenticule thickness group (>100 μm); (H) thinner lenticule thickness group (≤100 μm); (I) thicker preoperative CCT group (>550 μm); (J) thinner preoperative CCT group (≤550 μm). SD, standard deviation; Cl, confidence interval; df, degree(s) of freedom; l2, heterogeneity; Z, overall effect.

Discussion

The HOA stands for third-order or higher aberrations that are not correctable with conventional eyeglasses or contact lenses. The human eye’s non-flat optical plane leads to uneven refraction and curvature at all sites, which are essential for the development of HOA (32). Although SMILE has accurate cutting powers, it is unable to eliminate the occurrence of HOA. The meta-analysis results indicate a statistically significant induction of HOAs after SMILE compared to before the procedure, suggesting that SMILE can lead to a considerable induction of HOAs. The outcome was consistent in most research. Jun et al. (19) and Yin et al. (26) did not observe a significant induction of tHOA following SMILE in their trials. After reviewing the manuscripts from Yin et al. (26), we observed that the mean preoperative spherical equivalent (SE) of the study population was high (>-7D). However, the pupil diameter analyzed was only 4 mm, with most being 6 mm. It indicates that the induction of HOA in the central vision region may not be significant. Consequently, the decreased visual quality likely occurred more frequently at night following SMILE. Jun et al. (19) utilized a trifocal focus method for SMILE with a mean preoperative SE of approximately -3D, potentially accounting for the little induction of tHOA following their SMILE treatment.

Most studies on various forms of HOA have shown a considerable induction of SA after SMILE, and our meta-analysis confirmed these findings. Several investigations have shown varying results on the induction of SA after SMILE, possibly due to changes in instrumentation, dark-vision environment, and pupil size (33, 34). Kwak et al. (11) and Jun et al. (19) corroborated this using a trifocal focusing approach to decrease the induction of SA. Xia et al. (8) did not see a significant induction of SA, possibly because there were too few corneal areas analyzed (5 mm). Yin et al. (26) observed a notable induction of SA in the 4 mm corneal analysis areas, possibly due to severe myopia (−7.96 ± 0.94D). Greater myopia requires a thicker stromal lenticule to be sliced, leading to significant alterations in the cornea’s front surface and increased induction of SA. The femtosecond laser enables precise excision of corneal tissue, reducing the induction of SA compared to previous surgical methods (35). CA has also been found to be greatly introduced following SMILE, comparable to SA. This meta-analysis yielded consistent findings, except Jun et al. (19), who employed the trifocal focusing approach to minimize the induction of CA. Some studies suggest that a single incision during SMILE may result in an uneven corneal healing response, causing optical alterations that can lead to increased induction of CA in the postoperative period (36). Previous research has indicated that reducing eccentricity and promoting wound healing may affect the induction of CA (18). Li et al. (28) showed that horizontal eccentricity leads to horizontal CA induction, while there seems to be no connection between the extent of vertical eccentricity and vertical CA induction. More research is required to explore the origin of both vertical and horizontal CA to enhance the clarity of postoperative visual acuity. This meta-analysis did not discover any significant induction of TA caused by SMILE. Due to the absence of studies directly examining the relationship between TA and SMILE, we explored research on FS-LASIK. Kim et al. (37) discovered that HOAs changed after creating a flap in FS-LASIK, leading to the induction of CA and TA. They proposed that the location of the flap hinge and the microkeratome type could impact the type of aberrations induced during flap creation. The manifestation of TA induction, consistent with the incision location, is attributed to the biomechanical response that occurs after creating the corneal incision. This response involves the steepening of the corneal curvature near the flap hinge and flattening toward the free edge of the flap post-flap creation. SMILE utilizes a femtosecond laser to induce two distinct depth interlayer explosions within the cornea, followed by the creation of a tiny incision measuring 2-4 mm using the same laser. The corneal lenticule is extracted from the tiny incision. FS-LASIK involves creating a 20 mm corneal flap at approximately 270 degrees with a femtosecond laser, followed by cutting the corneal stroma behind the flap with an excimer laser. The reason for the minimal change in TA following SMILE is due to the smaller corneal incision or flap, indicating a distinct benefit in decreasing the induction of TA with SMILE (Table 3).

We examined the variations in the induction of HOA between SMILE and other types of corneal refractive surgeries in this meta-analysis. Comparing SMILE with FS-LASIK, the trials yielded diverse findings, but the combined outcome indicated that SMILE resulted in reduced induction of tHOA. Hamilton et al. (23) did not detect a difference between the techniques due to the use of a wavefront aberration optimization technique for FS-LASIK, which is slightly different from the WFG technique. Yang et al. (30) conducted research that yielded comparable results, which they attributed to the inclusion of participants with high myopia. The high degree of myopia itself dominated the postoperative HOA changes, leading to the fact that the different surgical modalities did not play a key role in this. Ganesh and Gupta (38) discovered no statistically significant difference between the SMILE and FS-LASIK groups in terms of HOA, SA, and CA induced at 6 months after correcting high myopia. This supports the speculation mentioned above, but more research is required to investigate the precise reasons. Contrary findings have been proposed by Li et al. (18) and Yin et al. (26), indicating that SMILE-induced HOA was notably lower than those of FS-LASIK (Table 3).

While LASIK and PRK use pupil-tracking devices to centrally focus on the cornea, SMILE requires the surgeon to manually center the instrument, usually with the corneal vertex as the target. According to the evidence that is now available, SA induction and subsequent tHOA induction both increased as the effective optical zone decentration from the corneal vertex did when SMILE used these centralized approaches (39). The outcomes of PRK and LASIK were also comparable. There was a robust relationship between the degree of vertical decentration and the degree of vertical CA induction. After reviewing the literature on WFG technology and comparing WFG refractive surgery with SMILE in this meta-analysis, we discovered that there was no significant difference in the induction of tHOA between the two procedures postoperatively. Also, while comparing WFG-PRK with SMILE, Jun et al. (19) discovered no statistically significant difference in corneal tHOA before or after surgery. This might be associated with the fact that SMILE makes use of the trifocal focusing approach. We next looked into the literature to see if SMILE had any influence on other kinds of HOA; we discovered that Ganesh and Gupta (38), Liu et al. (40), and Lin et al. (41) had previously found that SMILE-induced SA was much lower than WFG FS-LASIK. Rather than using corneal tissue photodetachment to create microlensing, they proposed that femtosecond laser-assisted tissue stripping could be responsible for the minimal SA induction in SMILE. Because astigmatism correction creates an elliptical posterior surface of the microlens, the optical surface’s diameter is smaller along the steep axis compared to the flat axis; as a result, Ye et al. (29) speculated that this might explain why SMILE caused more horizontal and vertical CA than WFG-LASIK. In addition, the vertical edge of the refractive microlens in SMILE may also contribute to coma compared with the 2.0 mm transition zone around the optical zone in WFG-LASIK. Related to the aforementioned results, Gulmez et al. (25) and Gyldenkerne et al. (42) discovered that SMILE caused more vertical CA and TA than WFG FS-LASIK, and that WFG FS-LASIK caused more SA than SMILE. So there are still significant differences between the various types of HOAs, even if there was no change in the induction of tHOA. Corneal refractive surgery guided by corneal topography is also one of the most popular ways now utilized, both SMILE and its approaches have proven to be effective and safe, according to FDA investigations. However, which technique is better is up for debate because different patients with varied corneal characteristics, topographic irregularities, or HOAs have shown advantages and disadvantages with each treatment (43). Several prospective studies have shown that topography-guided LASIK (TG-LASIK) reduces ocular TA, corneal tHOA, and CA, and causes fewer HOAs overall (44). To achieve the best possible corneal curvature, TG-LASIK uses measurements of the cornea’s topography to guide a personalized ablation procedure. In TG-LASIK, unlike wavefront measurements, the corneal curvature may be measured regardless of the size of the pupil. Correction of peripheral corneal abnormalities on the cornea, where most HOAs of the optical system of the eye emerge, is possible using topography-guided bespoke ablation treatment, and it is not affected by mistakes caused by the pupil centroid shift when the pupil changes size (45, 46). When comparing SMILE and other methods, Yang et al. (47) discovered that SMILE successfully reduced surgically caused HOAs by adjusting for the kappa angle using topography as a reference. When it comes to correcting astigmatism and preoperative anterior corneal hyperopia, TG-LASIK with iris recognition and cyclotorsional adjustment is the way to go.

This meta-analysis investigated factors that could affect the induction of HOA following SMILE. This meta-analysis discovered that the induction of postoperative tHOA was notably greater in the high myopia group (sphere >-5D) compared to the low myopia group (sphere ≤-5D). Just as Jin et al. (27) found that the corneal tHOA, notably vertical CA and SA, were connected to the SE. These results are comparable to the study by Wu and Wang (7), who stated that more investigations are needed to determine the etiology of vertical and horizontal CA to optimize postoperative visual quality. We hypothesize that this effect should be related to the fact that the higher the degree of myopia, the thicker the lens would be cut, thus leading to a stronger induction of postoperative HOA. In contrast, the effect of astigmatism was inverted, and this meta-analysis indicated that the induction of tHOA by SMILE was substantially higher in the group with lower astigmatism (cylinder ≤-1D) than in the group with higher astigmatism (cylinder >-1D). We investigated relevant literature and re-examined the original data to discover the cause. We showed that although SMILE obtained a circular optical zone in the treatment of myopia and astigmatism, astigmatism specifically achieved an elliptical functional optical zone (FOZ). Liu et al. (48) validated in their investigation that eyes with significant astigmatism achieved a higher FOZ and lesser SA induction following SMILE compared to eyes without astigmatism. Therefore, they believe that increasing the size of FOZ can lessen the influence of eccentricity on HOA induction. Recently, Moshirfar et al. (39) have hypothesized that SMILE produces a larger FOZ than LASIK and PRK, which is crucial to minimizing HOA induction. Therefore, they argue that ensuring sufficient FOZ can reduce HOA induction, including SA and vertical CA. This may be the reason why increased astigmatism induces less HOA. In addition, we also analyzed other relevant characteristics of these studies and discovered that the average myopia degree in the high astigmatism group (mean sphere = −4.35 ± 0.66D) was lower than that in the low astigmatism group (mean sphere = −5.23 ± 1.36D). According to the earlier analysis of myopia degree, this will lead to reduced HOA induction in the high astigmatism group due to low myopia degree. However, we observed that there was no significant difference in the degree of myopia between these two groups (p = 0.13), thus we suggest that the difference in myopia may be involved in confusing the results, but it is not a crucial issue. Therefore, we believe that the key to the influence of astigmatism on HOA induction is still the magnitude of FOZ, which may indicate that larger astigmatism has less HOA induction. Additional study is required to validate this finding with improved control over pertinent variables.

We also found a substantial tHOA induced in the 1-month follow-up group following SMILE compared to the 6-month follow-up group in this meta-analysis, consistent with findings from studies with longer follow-up periods. According to Pedersen et al. (49), CA remained constant, whereas less SA and tHOA were induced significantly from 3 months to 3 years after SMILE. Most studies have consistently reported enduring stability in HOA following SMILE. Xia et al. (8) discovered that levels of tHOA, SA, CA, and TA remained consistent at specific postoperative time intervals following SMILE, aligning closely with findings from studies by Li et al. (18), Lin et al. (41), and Ağca et al. (50). For the lenticule thickness, Wallerstein et al. (51) verified that in FS-LASIK, the postoperative HOA was considerably higher in the group with a lenticule thickness larger than 100 μm compared to the group with a lenticule thickness less than 100 μm. We believe that increasing the depth of ablation will reduce the precision of ablation from SMILE, and the refractive difference induced by the ablation edge will also be more significant. Eyes with greater lens thickness tend to have a reduced residual corneal bed and corneal thickness, leading to less biomechanical stability and increased induction of HOA. It is logical to assume that the mentioned causes can result in this contrasted outcome, and the connection between myopia severity and the alteration in HOA before and after surgery is somewhat influenced by this. Our study also demonstrated that the SMILE preoperative CCT above 550 μm group produced significantly higher postoperative HOA than the preoperative CCT below 550 μm group. Feng et al. (52) suggested that keeping a larger residual CCT (preoperative CCT) with FS-LASIK can result in reduced SA, despite the absence of specific analysis. They hypothesize that alterations in corneal shape can result in biomechanical modifications, suggesting that HOA could be associated with postoperative biomechanical changes following FS-LASIK. Yet, the evaluation of SMILE appears to be more consistent, as a decrease in corneal thickness does not necessarily result in increased induction of postoperative HOA. Mohamed et al. (53) found no link between central/peripheral corneal thickness and HOA in the eye and cornea. Qu et al. (54) discovered that just one Zernike aberration, Z42, was significantly linked to CCT in corneal HOA. We believe that the results require validation from more investigations. There is also a link between myopia, lenticule thickness, and CCT. A higher degree of myopia requires a thicker lenticule to be sliced, resulting in a thinner postoperative CCT. The correlation between these parameters and HOA is linked to the biomechanical stability of the cornea. Previous studies have shown that the biomechanical stability of the cornea is significantly correlated with the 3rd to 6th-order HOAs and SA induced on the anterior surface and total cornea after SMILE (55). We hypothesize that the relationship between these factors and HOA may be attributed to corneal biomechanics. Future studies in this field will help clarify their direct association and influence (Table 4).

Table 4
www.frontiersin.org

Table 4. Meta-analysis and comparative results of influencing factors on HOA changes after SMILE.

There are some limitations of our study: (1) Due to the diverse origins of these studies, variations in aberration analyzers, and differences in populations, the results of aberration measurements and analyses may be somewhat influenced. However, this study primarily focused on comparing HOA before and after SMILE, with no changes observed in these factors before and after the procedure. Hence, the impact of these differences can be mostly disregarded. (2) Most studies use a 6 mm pupil size for analyzing HOA, but a few studies use a smaller diameter of 5 mm or less (some do not specify). Detecting HOA changes becomes challenging with a small pupil size, which can influence the disparity in HOA before and after surgery. (3) Ocular HOA mostly originates from the cornea but also involves refractive components such as the lens, anterior chamber, and vitreous. Only a few studies in this meta-analysis focused on whole-eye HOA, which may have partially impacted the accuracy. However, as SMILE is a type of corneal refractive surgery that only alters the cornea, this issue has minimal influence. (4) Discrepancies in the postoperative duration of follow-up may result in alterations in HOA, so selecting varying time intervals following the surgery can provide diverse outcomes. The study attempted to use a uniform postoperative follow-up period of 6 months for analysis, but this variation still impacted the results of the analysis. (5) The choice of cutting area, energy level, and corneal cap thickness in SMILE can impact the variations in HOA. This study aims to choose coherent studies for analysis, while minor distinctions may still impact the final result. Other factors such as selection bias and publication bias may also have some impact on this meta-analysis.

Conclusion

According to this analysis and previous studies, SMILE can dramatically increase the induction of tHOA, SA, and CA, but not TA. SMILE can greatly decrease the induction of tHOA compared to FS-LASIK, and there is no notable difference in tHOA generated by WFG refractive surgery. After categorizing by various factors, the group with severe myopia (sphere >-5D), lower astigmatism (cylinder ≤-1D), shorter duration of postoperative follow-up (1 month), thicker lenticule (over 100 μm), and higher preoperative CCT (over 550 μm) exhibited increased induction of tHOA compared to their respective control groups during SMILE. Despite the inevitable induction of HOA, SMILE remains a safe and successful procedure for corneal refractive surgery, particularly in minimizing the induction of tHOA, SA, and CA. When choosing surgical techniques in clinical practice, it is important to examine issues such as safety, effectiveness, postoperative complications, and the potential induction of postoperative HOA. To some extent, ensuring the stability of visual quality in myopic populations can be achieved by minimizing the occurrence of postoperative HOA during surgery.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Author contributions

YiD: Writing – review & editing, Writing – original draft, Methodology, Investigation, Funding acquisition, Formal analysis, Data curation, Conceptualization. YuD: Writing – original draft, Investigation, Data curation. SY: Writing – original draft, Resources, Formal analysis. FM: Writing – original draft, Software, Methodology. GC: Writing – original draft, Resources. DC: Writing – review & editing, Visualization, Validation. YL: Writing – review & editing, Visualization, Validation, Supervision, Methodology, Funding acquisition.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This study was Supported by grants from the National Natural Science Foundation of China (82000863 to YL). The sponsor or funding organization had no role in the design or conduct of this research.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Pan, CW, Ramamurthy, D, and Saw, SM. Worldwide prevalence and risk factors for myopia. Ophthalmic Physiol Opt. (2012) 32:3–16. doi: 10.1111/j.1475-1313.2011.00884.x

Crossref Full Text | Google Scholar

2. McAlinden, C . Corneal refractive surgery: past to present. Clin Exp Optom. (2012) 95:386–98. doi: 10.1111/j.1444-0938.2012.00761.x

Crossref Full Text | Google Scholar

3. Ang, M, Gatinel, D, Reinstein, DZ, Mertens, E, Alió Del Barrio, JL, and Alió, JL. Refractive surgery beyond 2020. Eye. (2021) 35:362–82. doi: 10.1038/s41433-020-1096-5

PubMed Abstract | Crossref Full Text | Google Scholar

4. Sekundo, W, Kunert, KS, and Blum, M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. (2011) 95:335–9. doi: 10.1136/bjo.2009.174284

Crossref Full Text | Google Scholar

5. Krueger, RR, and Meister, CS. A review of small incision lenticule extraction complications. Curr Opin Ophthalmol. (2018) 29:292–8. doi: 10.1097/ICU.0000000000000494

Crossref Full Text | Google Scholar

6. Wen, D, McAlinden, C, Flitcroft, I, Tu, R, Wang, Q, Alió, J, et al. Postoperative efficacy, predictability, safety, and visual quality of laser corneal refractive surgery: a network Meta-analysis. Am J Ophthalmol. (2017) 178:65–78. doi: 10.1016/j.ajo.2017.03.013

PubMed Abstract | Crossref Full Text | Google Scholar

7. Wu, W, and Wang, Y. Corneal higher-order aberrations of the anterior surface, posterior surface, and Total cornea after SMILE, FS-LASIK, and FLEx surgeries. Eye Contact Lens. (2016) 42:358–65. doi: 10.1097/ICL.0000000000000225

PubMed Abstract | Crossref Full Text | Google Scholar

8. Xia, F, Shen, Y, Han, T, Zhao, J, Xu, H, and Zhou, X. Small incision Lenticule extraction (SMILE) for moderate and high myopia: seven-year outcomes of refraction, corneal tomography, and Wavefront aberrations. J Ophthalmol. (2020) 2020:3825864–7. doi: 10.1155/2020/3825864

PubMed Abstract | Crossref Full Text | Google Scholar

9. Manche, E, and Roe, J. Recent advances in wavefront-guided LASIK. Curr Opin Ophthalmol. (2018) 29:286–91. doi: 10.1097/ICU.0000000000000488

PubMed Abstract | Crossref Full Text | Google Scholar

10. Zhang, Y, Sun, X, and Chen, Y. Comparison of corneal optical quality after SMILE, Wavefront-optimized LASIK and topography-guided LASIK for myopia and myopic astigmatism. Front Med. (2022) 9:870330. doi: 10.3389/fmed.2022.870330

PubMed Abstract | Crossref Full Text | Google Scholar

11. Kwak, JJ, Jun, I, Kim, EK, Seo, KY, and Kim, TI. Clinical outcomes of small incision Lenticule extraction in myopia: study of vector parameters and corneal aberrations. Korean J Ophthalmol. (2020) 34:76–84. doi: 10.3341/kjo.2019.0109

PubMed Abstract | Crossref Full Text | Google Scholar

12. Zhong, Y, Li, M, Han, T, Fu, D, and Zhou, X. Four-year outcomes of small incision lenticule extraction (SMILE) to correct high myopic astigmatism. Br J Ophthalmol. (2021) 105:27–31. doi: 10.1136/bjophthalmol-2019-315619

PubMed Abstract | Crossref Full Text | Google Scholar

13. Stroup, DF, Berlin, JA, Morton, SC, Olkin, I, Williamson, GD, Rennie, D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis of observational studies in epidemiology (MOOSE) group. JAMA. (2000) 283:2008–12. doi: 10.1001/jama.283.15.2008

PubMed Abstract | Crossref Full Text | Google Scholar

14. Moher, D, Liberati, A, Tetzlaff, J, and Altman, DGPRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. (2009) 6:e1000097. doi: 10.1371/journal.pmed.1000097

PubMed Abstract | Crossref Full Text | Google Scholar

15. Stang, A . Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of non-randomized studies in meta-analyses. Eur J Epidemiol. (2010) 25:603–5. doi: 10.1007/s10654-010-9491-z

PubMed Abstract | Crossref Full Text | Google Scholar

16. Egger, M, Davey Smith, G, Schneider, M, and Minder, C. Bias in meta-analysis detected by a simple, graphical test. BMJ. (1997) 315:629–34. doi: 10.1136/bmj.315.7109.629

PubMed Abstract | Crossref Full Text | Google Scholar

17. Begg, CB, and Mazumdar, M. Operating characteristics of a rank correlation test for publication bias. Biometrics. (1994) 50:1088–101. doi: 10.2307/2533446

PubMed Abstract | Crossref Full Text | Google Scholar

18. Li, X, Wang, Y, and Dou, R. Aberration compensation between anterior and posterior corneal surfaces after small incision lenticule extraction and femtosecond laser-assisted laser in-situ keratomileusis. Ophthalmic Physiol Opt. (2015) 35:540–51. doi: 10.1111/opo.12226

PubMed Abstract | Crossref Full Text | Google Scholar

19. Jun, I, Kang, DSY, Reinstein, DZ, Arba-Mosquera, S, Archer, TJ, Seo, KY, et al. Clinical outcomes of SMILE with a triple centration technique and corneal Wavefront-guided Transepithelial PRK in high astigmatism. J Refract Surg. (2018) 34:156–63. doi: 10.3928/1081597X-20180104-03

PubMed Abstract | Crossref Full Text | Google Scholar

20. Yu, M, Chen, M, Liu, W, and Dai, J. Comparative study of wave-front aberration and corneal Asphericity after SMILE and LASEK for myopia: a short and long term study. BMC Ophthalmol. (2019) 19:80. doi: 10.1186/s12886-019-1084-3

PubMed Abstract | Crossref Full Text | Google Scholar

21. Lee, H, Yong Kang, DS, Reinstein, DZ, Arba-Mosquera, S, Kim, EK, Seo, KY, et al. Comparing corneal higher-order aberrations in corneal wavefront-guided transepithelial photorefractive keratectomy versus small-incision lenticule extraction. J Cataract Refract Surg. (2018) 44:725–33. doi: 10.1016/j.jcrs.2018.03.028

PubMed Abstract | Crossref Full Text | Google Scholar

22. Jun, I, Kang, DSY, Roberts, CJ, Lee, H, Jean, SK, Kim, EK, et al. Comparison of clinical and biomechanical outcomes of small incision Lenticule extraction with 120- and 140-μm cap thickness. Transl Vis Sci Technol. (2021) 10:15. doi: 10.1167/tvst.10.8.15

PubMed Abstract | Crossref Full Text | Google Scholar

23. Hamilton, DR, Chen, AC, Khorrami, R, Nutkiewicz, M, and Nejad, M. Comparison of early visual outcomes after low-energy SMILE, high-energy SMILE, and LASIK for myopia and myopic astigmatism in the United States. J Cataract Refract Surg. (2021) 47:18–26. doi: 10.1097/j.jcrs.0000000000000368

PubMed Abstract | Crossref Full Text | Google Scholar

24. Chen, X, Wang, Y, Zhang, J, Yang, SN, Li, X, and Zhang, L. Comparison of ocular higher-order aberrations after SMILE and Wavefront-guided femtosecond LASIK for myopia. BMC Ophthalmol. (2017) 17:42. doi: 10.1186/s12886-017-0431-5

PubMed Abstract | Crossref Full Text | Google Scholar

25. Gulmez, M, Tekce, A, and Kamıs, U. Comparison of refractive outcomes and high-order aberrations after small incision lenticule extraction and wavefront-guided femtosecond-assisted laser in situ keratomileusis for correcting high myopia and myopic astigmatism. Int Ophthalmol. (2020) 40:3481–9. doi: 10.1007/s10792-020-01534-x

Crossref Full Text | Google Scholar

26. Yin, Y, Lu, Y, Xiang, A, Fu, Y, Zhao, Y, Li, Y, et al. Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study. BMC Ophthalmol. (2021) 21:292. doi: 10.1186/s12886-021-02048-5

PubMed Abstract | Crossref Full Text | Google Scholar

27. Jin, HY, Wan, T, Yu, XN, Wu, F, and Yao, K. Corneal higher-order aberrations of the anterior surface, posterior surface, and total cornea after small incision lenticule extraction (SMILE): high myopia versus mild to moderate myopia. BMC Ophthalmol. (2018) 18:295. doi: 10.1186/s12886-018-0965-1

PubMed Abstract | Crossref Full Text | Google Scholar

28. Li, MY, Li, M, Chen, Y, Miao, H, Yang, D, Ni, K, et al. Five-year results of small incision lenticule extraction (SMILE) and femtosecond laser LASIK (FS-LASIK) for myopia. Acta Ophthalmol. (2019) 97:e373–80. doi: 10.1111/aos.14017

PubMed Abstract | Crossref Full Text | Google Scholar

29. Ye, MJ, Liu, CY, Liao, RF, Gu, ZY, Zhao, BY, and Liao, Y. SMILE and Wavefront-guided LASIK out-compete other refractive surgeries in ameliorating the induction of high-order aberrations in anterior corneal surface. J Ophthalmol. (2016) 2016:8702162–7. doi: 10.1155/2016/8702162

PubMed Abstract | Crossref Full Text | Google Scholar

30. Yang, W, Liu, S, Li, M, Shen, Y, and Zhou, X. Visual outcomes after small incision Lenticule extraction and femtosecond laser-assisted LASIK for high myopia. Ophthalmic Res. (2020) 63:427–33. doi: 10.1159/000504304

PubMed Abstract | Crossref Full Text | Google Scholar

31. Kang, DSY, Lee, H, Reinstein, DZ, Roberts, CJ, Arba-Mosquera, S, Archer, TJ, et al. Comparison of the distribution of Lenticule Decentration following SMILE by subjective patient fixation or triple marking centration. J Refract Surg. (2018) 34:446–52. doi: 10.3928/1081597X-20180517-02

PubMed Abstract | Crossref Full Text | Google Scholar

32. Liang, J, Grimm, B, Goelz, S, and Bille, JF. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-shack wave-front sensor. J Opt Soc Am A Opt Image Sci Vis. (1994) 11:1949–57. doi: 10.1364/josaa.11.001949

PubMed Abstract | Crossref Full Text | Google Scholar

33. Qin, B, Zhao, J, Li, M, Yao, P, and Zhou, X. The comparison of visual outcomes, aberrations, and Bowman's layer micro-distortions after femtosecond laser small-incision lenticule extraction (SMILE) for the correction of high and moderate myopia and myopic astigmatism. BMC Ophthalmol. (2019) 19:138. doi: 10.1186/s12886-019-1135-9

PubMed Abstract | Crossref Full Text | Google Scholar

34. Shetty, R, Matalia, H, Nandini, C, Shetty, A, Khamar, P, Grover, T, et al. Wavefront-guided LASIK has comparable ocular and corneal aberrometric outcomes but better visual acuity outcomes than SMILE in myopic eyes. J Refract Surg. (2018) 34:527–32. doi: 10.3928/1081597X-20180607-02

PubMed Abstract | Crossref Full Text | Google Scholar

35. Damgaard, IB, Ang, M, Mahmoud, AM, Farook, M, Roberts, CJ, and Mehta, JS. Functional optical zone and centration following SMILE and LASIK: a prospective, randomized, contralateral eye study. J Refract Surg. (2019) 35:230–7. doi: 10.3928/1081597X-20190313-01

PubMed Abstract | Crossref Full Text | Google Scholar

36. Yu, Y, Zhang, W, Cheng, X, Cai, J, and Chen, H. Impact of treatment decentration on higher-order aberrations after SMILE. J Ophthalmol. (2017) 2017:9575723–7. doi: 10.1155/2017/9575723

PubMed Abstract | Crossref Full Text | Google Scholar

37. Kim, SW, Yang, H, Yoon, G, Lee, YJ, Kweon, MN, Kim, JK, et al. Higher-order aberration changes after implantable Collamer Lens implantation for myopia. Am J Ophthalmol. (2011) 151:653–662.e1. doi: 10.1016/j.ajo.2010.10.031

PubMed Abstract | Crossref Full Text | Google Scholar

38. Ganesh, S, and Gupta, R. Comparison of visual and refractive outcomes following femtosecond laser- assisted lasik with smile in patients with myopia or myopic astigmatism. J Refract Surg. (2014) 30:590–6. doi: 10.3928/1081597X-20140814-02

Crossref Full Text | Google Scholar

39. Moshirfar, M, Herron, MS, Cha, DS, Santos, J, Payne, CJ, and Hoopes, PC. Comparing effective optical zones after myopic ablation between LASIK, PRK, and SMILE with correlation to higher order aberrations. J Refract Surg. (2023) 39:741–50. doi: 10.3928/1081597X-20231016-02

PubMed Abstract | Crossref Full Text | Google Scholar

40. Liu, M, Chen, Y, Wang, D, Zhou, Y, Zhang, X, He, J, et al. Clinical outcomes after SMILE and femtosecond laser-assisted LASIK for myopia and myopic astigmatism: a prospective randomized comparative study. Cornea. (2016) 35:210–6. doi: 10.1097/ICO.0000000000000707

PubMed Abstract | Crossref Full Text | Google Scholar

41. Lin, F, Xu, Y, and Yang, Y. Comparison of the visual results after SMILE and femtosecond laser-assisted LASIK for myopia. J Refract Surg. (2014) 30:248–54. doi: 10.3928/1081597X-20140320-03

Crossref Full Text | Google Scholar

42. Gyldenkerne, A, Ivarsen, A, and Hjortdal, JØ. Comparison of corneal shape changes and aberrations induced by FS-LASIK and SMILE for myopia. J Refract Surg. (2015) 31:223–9. doi: 10.3928/1081597X-20150303-01

PubMed Abstract | Crossref Full Text | Google Scholar

43. Schallhorn, JM, Seifert, S, and Schallhorn, SC. SMILE, topography-guided LASIK, and Wavefront-guided LASIK: review of clinical outcomes in premarket approval FDA studies. J Refract Surg. (2019) 35:690–8. doi: 10.3928/1081597X-20190930-02

PubMed Abstract | Crossref Full Text | Google Scholar

44. Jain, AK, Malhotra, C, Pasari, A, Kumar, P, and Moshirfar, M. Outcomes of topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia in virgin eyes. J Cataract Refract Surg. (2016) 42:1302–11. doi: 10.1016/j.jcrs.2016.06.035

PubMed Abstract | Crossref Full Text | Google Scholar

45. Stulting, RD, Fant, BS, T-CAT Study GroupBond, W, Chotiner, B, Durrie, D, et al. Results of topography-guided laser in situ keratomileusis custom ablation treatment with a refractive excimer laser. J Cataract Refract Surg. (2016) 42:11–8. doi: 10.1016/j.jcrs.2015.08.016

PubMed Abstract | Crossref Full Text | Google Scholar

46. Kang, EM, Ryu, IH, Lee, IS, Kim, JK, Kim, SW, and Ji, YW. Comparison of corneal higher-order aberrations following topography-guided LASIK and SMILE for myopic correction: a propensity score matching analysis. J Clin Med. (2022) 11:6171. doi: 10.3390/jcm11206171

PubMed Abstract | Crossref Full Text | Google Scholar

47. Yang, LJ, Liu, X, Mi, SJ, Sun, L, and Chen, MX. Early visual function outcomes of topography-guided FS-LASIK and SMILE in treatment of myopia and myopic astigmatism. Int J Ophthalmol. (2021) 14:423–9. doi: 10.18240/ijo.2021.03.15

PubMed Abstract | Crossref Full Text | Google Scholar

48. Liu, S, Gu, X, Zhang, X, Zhao, J, and Zhou, X. Achieved and functional optical zone in myopic eyes with high astigmatism after small incision Lenticule extraction. J Refract Surg. (2022) 38:243–9. doi: 10.3928/1081597X-20220201-01

PubMed Abstract | Crossref Full Text | Google Scholar

49. Pedersen, IB, Ivarsen, A, and Hjortdal, J. Three-year results of small incision Lenticule extraction for high myopia: refractive outcomes and aberrations. J Refract Surg. (2015) 31:719–24. doi: 10.3928/1081597X-20150923-11

PubMed Abstract | Crossref Full Text | Google Scholar

50. Ağca, A, Demirok, A, Cankaya, Kİ, Yaşa, D, Demircan, A, Yildirim, Y, et al. Comparison of visual acuity and higher-order aberrations after femtosecond lenticule extraction and small-incision lenticule extraction. Cont Lens Anterior Eye. (2014) 37:292–6. doi: 10.1016/j.clae.2014.03.001

PubMed Abstract | Crossref Full Text | Google Scholar

51. Wallerstein, A, Gauvin, M, and Cohen, M. Effect of anterior corneal higher-order aberration ablation depth on primary topography-guided LASIK outcomes. J Refract Surg. (2019) 35:754–62. doi: 10.3928/1081597X-20191021-02

PubMed Abstract | Crossref Full Text | Google Scholar

52. Feng, Z, Wang, Q, Du, C, Yang, F, and Li, X. High-order aberration changes after femtosecond LASIK surgery in patients with high myopia. Ann Palliat Med. (2021) 10:7689–96. doi: 10.21037/apm-21-1677

Crossref Full Text | Google Scholar

53. Mohamed, EM, Wojtowicz, JC, Bowman, W, Cavanagh, HD, Mootha, V, Verity, S, et al. Corneal thickness association with ocular and corneal high-order aberrations. Eye Contact Lens. (2009) 35:297–301. doi: 10.1097/ICL.0b013e3181b93bed

PubMed Abstract | Crossref Full Text | Google Scholar

54. Qu, J, Lu, F, Wu, J, Wang, Q, Xu, C, Zhou, X, et al. Wavefront aberration and its association with intraocular pressure and central corneal thickness in myopic eyes. J Cataract Refract Surg. (2007) 33:1447–54. doi: 10.1016/j.jcrs.2007.04.012

PubMed Abstract | Crossref Full Text | Google Scholar

55. Wu, W, and Wang, Y. The correlation analysis between corneal biomechanical properties and the surgically induced corneal high-order aberrations after small incision Lenticule extraction and femtosecond laser in situ Keratomileusis. J Ophthalmol. (2015) 2015:758196. doi: 10.1155/2015/758196

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: high order aberrations, small incision lenticule extraction, myopia, spherical aberration, coma aberration, trefoil aberration

Citation: Du Y, Di Y, Yang S, Mo F, Cui G, Chen D and Li Y (2024) Differences in ocular high order aberrations before and after small incision lenticule extraction for correction of myopia: a systematic review and meta-analysis. Front. Med. 11:1274101. doi: 10.3389/fmed.2024.1274101

Received: 07 August 2023; Accepted: 13 March 2024;
Published: 27 March 2024.

Edited by:

Jinhai Huang, Fudan University, China

Reviewed by:

Majid Moshirfar, University of Utah, United States
Hongying Jin, Zhejiang University, China

Copyright © 2024 Du, Di, Yang, Mo, Cui, Chen and Li. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ying Li, liyingpumch@126.com

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.