Abstract
Introduction:
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease with ocular involvement in up to 30% of cases. Due to its type I collagen composition, the cornea is particularly susceptible to thinning due to immune-complex deposition. A reduced central corneal thickness (CCT) is clinically relevant in glaucoma, where a thinner CCT increases glaucoma risk and in refractive surgery planning. Previous studies on CCT in SLE are limited due to methodological heterogeneity, technology use, inclusion criteria, and sample size, resulting in conflicting findings. This study aims to evaluate and compare the mean CCT values between patients with SLE and healthy controls.
Materials and methods:
This cross-sectional study assessed mean CCT in 71 participants, 36 patients with SLE and 35 age- and sex-matched healthy controls, recruited from ophthalmology consultations. Participants with other risk factors for corneal thinning were excluded. A pilot study estimated a sample size of 34 participants per group. After confirming concordance using the Kappa index, one randomly selected eye per participant was included. CCT was measured using Zeiss HD Cirrus 5,000 optical coherence tomography. Correlation analysis was conducted using Spearmanās Rho coefficient, while a Loess regression was performed to visualize both linear and non-linear trends. Multivariate linear regression assessed the relationship between CCT, SLE, and other variables.
Results:
Patients in the SLE group exhibited significantly thicker CCT than controls (536.44āÆĀ±āÆ39.91āÆĪ¼m vs. 517.57āÆĀ±āÆ29.62āÆĪ¼m, pāÆ=āÆ0.014). Intraocular pressure (IOP) was similar between groups (14.31āÆĀ±āÆ3.12āÆmmHg vs. 14.54āÆĀ±āÆ2.36āÆmmHg, pāÆ=āÆ0.898). CCT positively correlated with the length of hydroxychloroquine (HCQ) use (R: 0.357; pāÆ=āÆ0.041), showing a trend toward an increase with prolonged usage, peaking approximately 100āÆmonths. Multivariate regression confirmed the association between SLE and higher CCT, potentially due to HCQ use.
Discussion:
We established an association between CCT and the presence of SLE, with SLE patients exhibiting significantly higher CCT values, potentially due to hydroxychloroquine use. These findings have important implications for IOP assessment, glaucoma risk evaluation, and refractive surgery planning in SLE patients and those undergoing treatment with HCQ. Further prospective studies are warranted to validate these observations and explore the underlying mechanisms.
Introduction
Systemic lupus erythematosus (SLE) is a chronic autoimmune and multisystemic disease categorized as a āconnective tissue disease.ā In Europe, SLE is estimated to affect 39 out of every 100,000 individuals (1), with the highest prevalence observed among young women and individuals of Black, Asian, or Hispanic background (2). The European League Against Rheumatism (EULAR) and the American College of Rheumatology (ACR) have developed classification criteria for SLE, with a sensitivity of 96.1% and a specificity of 93.4% (3). However, not all patients meet these criteria, and many suffer from diagnostic delays and misdiagnosis.
SLE can potentially affect any tissue, organ, or system, with a preference for the musculoskeletal system, skin, and kidneys (4). Ocular involvement is also notable and can occur in up to 30% of patients (1, 5). These ocular manifestations, as noted by the British Isles Lupus Assessment Group (BILAG), are often excluded from the overall SLE activity assessment (1). Ocular abnormalities frequently correlate with systemic disease activity (5), yet they may go undetected because they can be asymptomatic or paucisymptomatic (1, 5), leading to treatment delay and a worse visual prognosis. This underscores the importance of ophthalmologic evaluation in both the diagnosis and monitoring of SLE.
The most common ocular manifestations in SLE are keratoconjunctivitis sicca due to secondary Sjƶgrenās syndrome (1, 6) and bilateral small vessel retinal vasculitis (1, 4, 6, 7). Other manifestations include recurrent corneal erosions, stromal corneal infiltration, peripheral ulcerative keratitis (PUK) (5), corneal edema (4), choroidal effusion, optic neuropathy (1), orbital or eyelid inflammation, and various retinal vascular abnormalities, such as vascular occlusions in relation to associated antiphospholipid syndrome (1).
Since the cornea is primarily composed of type I connective tissue (4, 6), it is particularly vulnerable to thinning and lysis phenomena in SLE due to inflammation caused by the deposits of immunocomplexes and autoantibodies (specifically anti-double-stranded DNA antibodies, anti-dsDNA, and anti-Smith antibodies, anti-Sm) in its basement membrane (4, 8). A limited number of studies have investigated the relationship between SLE and central corneal thickness (CCT), including those by Zang et al. (9), ĆaÄlayan et al. (10), Yazici et al. (4), Mahendradas et al. (8), Eissa et al. (6), Kaya et al. (11), and Mahmoud et al. (5). However, these studies are significantly heterogeneous in their methodology, use of technology, inclusion criteria, and sample size, resulting in conflicting results. This results in uncertainty regarding CCT involvement in SLE, highlighting the need for further research.
In addition, medications commonly used to treat SLE, such as corticosteroids and hydroxychloroquine (HCQ), can have significant ocular side effects (1). The latest EULAR guidelines recommended HCQ for all SLE patients unless contraindication (12); consequently, most SLE patients are expected to be on prolonged HCQ therapy. HCQ can affect the cornea (13), leading to verticillate keratopathy (1) and alterations in endothelial cell density, and may result in CCT thickening (8, 10). It can also affect the ciliary body and retinal pigment epithelium (RPE), potentially resulting in maculopathy (1). Corticosteroids, meanwhile, increase the risk of both cataracts and glaucoma (1). Given these potential ocular complications, regular ophthalmologic monitoring is essential to mitigate the risk of vision impairment (1).
CCT measurement is essential for accurate intraocular pressure (IOP) assessment (14) and is a major source of error in applanation tonometry (15). A thicker cornea leads to overestimation of IOP; conversely, a thinner cornea results in underestimation (14). Accurate CCT evaluation is therefore crucial for diagnosing glaucoma, and also for diagnosing keratoconus and determining eligibility for corneal refractive surgery techniques such as Laser Assisted In Situ Keratomileusis (LASIK) or photorefractive keratectomy (PRK) (15ā17).
Given the corneaās susceptibility to thinning and lysis in SLE (4, 8) and the limited and inconsistent data regarding CCT in this population, further investigation is warranted. Based on the hypothesis that CCT is thinner in SLE patients compared to healthy individuals, this cross-sectional study aims to investigate the association between CCT and SLE by comparing mean CCT values between SLE patients and age- and sex-matched healthy controls using Zeiss HD Cirrus 5000ās optical coherence tomography (OCT).
Materials and methods
This cross-sectional study was conducted at the Department of Ophthalmology, General University Hospital of Elda, in collaboration with the University of Miguel HernƔndez of Elche, Spain. The study protocol was previously published (18). Patient recruitment occurred between July 2020 and November 2024.
The study was conducted in compliance with all legal and ethical principles, including the Declaration of Helsinki (WMA, 2008) and the Good Clinical Practices of the European Union. Written informed consent was obtained from all participants. No patient identification data were included in the data collection form. Instead, a code was used and cross-referenced to identify data stored in a locked cabinet and only accessed by the principal investigator.
In accordance with current research legislation, the study protocol was approved by the Institutional Review Board (IRB) of the General University Hospital of Elda (PI2020/06).
Given the limited available literature, characterized by small sample sizes and conflicting findings, a pilot study including the first 20 patients (10 SLE patients and 10 healthy controls) was used to estimate the sample size. The mean CCT was 525āÆĀ±āÆ25āÆĪ¼m in the SLE group and 510āÆĀ±āÆ24āÆĪ¼m in the control group. Establishing a bilateral hypothesis with a type 1 error of 5% and a type 2 error of 20% (80% power), the resulting effect size was 0.61. This calculation indicated a minimum of 34 participants per group.
SLE patients were consecutively recruited from those referred by the Rheumatology Department to the Ophthalmology Department for HCQ macular toxicity screening. Medical records were reviewed to ensure the fulfillment of all inclusion and exclusion criteria. Control subjects were selected from those accompanying SLE patients to their appointments and individuals attending Ophthalmology consultations for occupational eye exams or minor ocular issues. Controls were recruited from the Health Department of Elda and matched by sex and age.
Patients were excluded in case of pregnancy or lactation, African descent, pre-existing systemic or ocular conditions potentially affecting corneal thickness (e.g., keratoconus, corneal edema, uveitis, diabetes mellitus, and chronic obstructive pulmonary disease), a history of glaucoma, severe astigmatism (>āÆ3D), or severe myopia (ā„āÆ-6D or axial lengthāÆ>āÆ26āÆmm). Those who regularly used contact lenses, had a history of ocular trauma or surgery, were using topical treatments other than artificial tears, had received topical or inhaled corticosteroid treatment in the past 3āÆmonths, or had received periorbital corticosteroids or systemic prednisone treatment at doses ā„7.5āÆmg/day in the past 6āÆmonths were also excluded.
Examinations were conducted between 9:00āÆAM and 2:00āÆPM to minimize diurnal variations in measurements. After obtaining written informed consent, a clinical interview and the following ophthalmologic tests were performed: refraction, visual acuity, slit-lamp examination of the anterior segment, fundus examination, pachymetry using Zeiss Cirrus HD-OCT 5000, Goldmann applanation tonometry (GAT), Schirmer 2 test, biometry (including keratometry), 24-2 visual field (VF), and OCT of the optic nerve with pupil dilation using tropicamide. Pachymetry was performed before the instillation of anesthetic and GAT to avoid tear film alterations or corneal deformations that could affect measurements. All ocular tests were performed in a single visit by a single observer, ensuring consistency between groups. Socio-demographic data, comorbidities, SLE manifestations, treatments, and laboratory results were also collected.
The Zeiss Cirrus HD-OCT 5000 was equipped with the HD Cornea lens. This attachment facilitates the generation of pachymetric maps divided into three concentric zones (0ā2āÆmm, 2ā5āÆmm, and 5ā7āÆmm from the corneal center) by capturing 27,000 axial scans per second, with an axial resolution of 5āÆĪ¼m and a transverse resolution of 15āÆĪ¼m (19, 20). CCT measurements were obtained using the automated method (pachymetry map scan), based on 24 radial B-scans, each comprising 1,024 A-scans, covering a 9āÆmm diameter with a scan depth of 2āÆmm (20, 21). During the procedure, the patientās gaze was fixed on the internal target, and the horizontal scan line was aligned with the corneal apex, ensuring proper positioning over the visible hyperreflective corneal reflex. Scans were repeated if the initial image was poorly centered or exhibited suboptimal corneal apex reflection. At least three corneal OCT scans were conducted per participant, and the image with the highest signal strength (ā„60) and optimal quality was selected for analysis. For CCT measurements, the Cirrus HD-OCT software algorithm (version 10.0.0.14618) automatically identified the epithelium and endothelium boundaries, generating CCT map values for the three central corneal zones (19). The mean CCT value from the 0ā2āÆmm central sector was used for analysis.
Statistical analysis
Concordance analysis using the Kappa index demonstrated the perfect correlation between the right and the left eye (KāÆ=āÆ1); therefore, one eye per participant was randomly selected for analysis.
Statistical analysis was performed using the Statistical Package for the Social Sciences (SPSS) version 26.0.0 developed by IBM Corp. (Armonk, NY) for Windows. The analysis was first conducted on the entire sample, followed by a subgroup analysis of SLE patients.
Quantitative data were expressed as meanāÆĀ±āÆstandard deviation and categorical data as proportions. Normality was assessed using the KolmogorovāSmirnov test. As the variables did not follow a normal distribution (pāÆ<āÆ0.05), non-parametric tests were used. For group comparisons, quantitative variables were analyzed using the MannāWhitney U-test, while categorical variables were assessed using the chi-square test for independent groups. McNemarās test was used for dependent categorical variables, and Spearmanās Rho coefficient was used for correlation analysis. Loess regression was performed to visualize both linear and non-linear trends in the data. In addition, 95% confidence intervals (CI) were calculated for differences in proportions (categorical variable) and differences in means (quantitative variable) between the groups.
To minimize confounding bias and to adjust and evaluate potential interactions, multivariate linear regression was used to assess the relationship between CCT, SLE, and other factors. Both crude and adjusted coefficients were calculated for each variable. Statistical significance was defined as a p-value of <0.05. A stepwise variable selection process based on the Akaike information criterion (AIC) was performed for multivariate adjustment. Graphical analysis of goodness-of-fit was conducted, and no patterns suggesting heteroscedasticity, non-linearity, or non-normality were observed (Supplementary material 1).
Results
The study involved 71 patients, aged 18āÆyears or older, divided into two groups: 36 patients with SLE (Group 1) and 35 healthy controls (Group 2). Ten participants were male (14.1%), while 61 (85.9%) were female. The demographic and clinical characteristics of all participants are shown in Table 1 and details of the SLE group in Table 2.
Table 1
| Group 1 | Group 2 | p-value | |
|---|---|---|---|
| Eyes No. | 36 | 35 | |
| Gender No. (%) | 0.962 | ||
| Female | 31 (86.1%) | 30 (85.7%) | |
| Male | 5 (13.9%) | 5 (14.3%) | |
| Age (years) | |||
| MeanāÆĀ±āÆSD | 45.8āÆĀ±āÆ13.2 | 41.9āÆĀ±āÆ12.7 | 0.059 |
| Range | 20ā71 | 18ā65 | |
| RNFL No. (%) | 0.666 | ||
| Normal | 33 (91.7%) | 33 (94.3%) | |
| Abnormal | 3 (8.3%) | 2 (5.7%) | |
| VF No. (%) | 0.321 | ||
| Normal | 35 (97.2%) | 35 (100%) | |
| Glaucomatous | 1 (2.8%) | 0 (0%) | |
| Schirmer 2 No. (%) | 0.361 | ||
| Normal | 30 (83.3%) | 27 (77.1%) | |
| Abnormal | 6 (16.7%) | 8 (22.9%) |
Socio-demographic and clinical characteristics of all study participants.
Group 1: systemic lupus erythematosus group; Group 2: Control group. SD, standard deviation; RFNL, retinal nerve fiber layer; VF, visual field.
Table 2
| Group 1 (SLE) | |
|---|---|
| Raynaud (%) | |
| Yes | 6 (16.7%) |
| No | 30 (83.3%) |
| Ocular involvement (%) | |
| Yes | 3 (8.3%) |
| No | 33 (91.7%) |
| Musculoskeletal involvement (%) | |
| Yes | 20 (55.6%) |
| No | 16 (44.4%) |
| Mucocutaneous involvement (%) | |
| Yes | 14 (38.9%) |
| No | 22 (61.1%) |
| Renal involvement (%) | |
| Yes | 3 (8.3%) |
| No | 33 (91.7%) |
| Immunosuppressive treatmenta (%) | |
| Yes | 3 (8.3%) |
| No | 33 (91.7%) |
Socio-demographic and clinical characteristics of the SLE group.
Patients under active treatment with methotrexate, mycophenolate, azathioprine, belimumab, leflunomide, or tacrolimus.
SLE, systemic lupus erythematosus.
The mean age in Group 1 was 45.8āÆĀ±āÆ13.2āÆyears, compared to 41.9āÆĀ±āÆ12.7āÆyears in Group 2, with no statistically significant differences between groups (pāÆ=āÆ0.059). The mean duration of the SLE was 10.89āÆĀ±āÆ8.9āÆyears, and the mean time since the last SLE flare was 37.83āÆĀ±āÆ36.4āÆmonths. All patients in Group 1 were treated with HCQ at a daily dosage not exceeding 6.5āÆmg/kg/24āÆh with a mean duration of HCQ usage of 81.79āÆĀ±āÆ61.12āÆmonths. Three patients with SLE (8.3%) presented an altered retinal nerve fiber layer (RNFL), but only one patient (2.8%) demonstrated visual field defects and was diagnosed with glaucoma.
Table 3 summarizes the ocular tests for both study groups. The mean CCT in Group 1 was significantly thicker than in Group 2 (536.44āÆĀ±āÆ39.91āÆĪ¼m vs. 517.57āÆĀ±āÆ29.62āÆĪ¼m, pāÆ=āÆ0.014), with a mean difference (MD) of 18.87āÆĪ¼m (95% CI: 2.58ā36.45). No differences were observed in IOP between groups (14.31āÆĀ±āÆ3.12āÆmmHg vs. 14.54āÆĀ±āÆ2.36āÆmmHg, pāÆ=āÆ0.898). A significant difference was found in the spherical equivalent (SE), with patients in Group 1 showing a more hyperopic refractive error than Group 2.
Table 3
| Group 1 | Group 2 | p-value | |
|---|---|---|---|
| CCT (μm) | 0.014 | ||
| MeanāÆĀ±āÆSD | 536.44āÆĀ±āÆ39.91 | 517.57āÆĀ±āÆ29.62 | |
| Range | 443ā628 | 459ā581 | |
| IOP (mmHg) | 0.898 | ||
| MeanāÆĀ±āÆSD | 14.31āÆĀ±āÆ3.12 | 14.54āÆĀ±āÆ2.36 | |
| Range | 6ā20 | 10ā21 | |
| RNFL (μm) | 0.637 | ||
| MeanāÆĀ±āÆSD | 92.89āÆĀ±āÆ8.39 | 95.09āÆĀ±āÆ9.86 | |
| Range | 66ā108 | 74ā116 | |
| Sphere (D) | <0.001 | ||
| MeanāÆĀ±āÆSD | 0.74āÆĀ±āÆ1.58 | ā1.06āÆĀ±āÆ1.83 | |
| Range | ā2.5ā4 | ā5.25ā2.75 | |
| Cylinder (D) | 0.263 | ||
| MeanāÆĀ±āÆSD | ā0.76āÆĀ±āÆ0.57 | ā0.67āÆĀ±āÆ0.60 | |
| Range | ā2.75ā0 | ā2.25ā0 | |
| SE (D) | <0.001 | ||
| MeanāÆĀ±āÆSD | +0.47āÆĀ±āÆ1.65 | ā1.31āÆĀ±āÆ1.84 | |
| Range | ā2.75 ā +3.75 | ā6.25ā2.00 | |
| Mean-K (D) | 0.692 | ||
| MeanāÆĀ±āÆSD | 43.86āÆĀ±āÆ1.19 | 43.92āÆĀ±āÆ1.51 | |
| Range | 39.85ā46.34 | 41.37ā48.48 |
Ocular measurements in all study participants.
CCT, central corneal thickness; SD, standard deviation; μm, microns; mmHg, millimeters of mercury; IOP, intraocular pressure; RFNL, retinal nerve fiber layer; SE, spherical equivalent; D, dioptric; Mean-K, mean keratometry.
Table 4 presents the correlation analysis between CCT and several clinical variables. A moderate positive correlation was found between CCT and IOP (R: 0.307; pāÆ=āÆ0.009) and between CCT and time of HCQ usage (R: 0.357; pāÆ=āÆ0.041) (Figure 1). In addition, a moderate inverse correlation was detected between CCT and the presence of Raynaudās phenomenon (R: ā0.405; pāÆ=āÆ0.014) and with previous mucocutaneous symptoms (R: ā0.414; pāÆ=āÆ0.012). No correlation was found between CCT and the duration of SLE (R: 0.102; pāÆ=āÆ0.554) nor with the time since the last SLE flare (R: 0.199; pāÆ=āÆ0.244).
Table 4
| CCT | ||
|---|---|---|
| Duration of the SLE | R | 0.102 |
| p-value | 0.554 | |
| Time since the last SLE flare | R | 0.199 |
| p-value | 0.244 | |
| Time of HCQ usage | R | 0.357 |
| p-value | 0.041 | |
| Raynaud syndrome | R | ā0.405 |
| p-value | 0.014 | |
| Mucocutaneous involvement | R | ā0.414 |
| p-value | 0.012 | |
| IOP | R | 0.307 |
| p-value | 0.009 |
Correlation analysis of CCT and SLE characteristics.
SLE, systemic lupus erythematosus; CCT, central corneal thickness; HCQ, hydroxychloroquine; IOP, intraocular pressure.
Figure 1
Although there was no correlation between age and CCT (R: ā0.011; pāÆ=āÆ0.927), a trend toward decreasing CCT with increasing age was observed in both groups, with a more pronounced decline in the SLE group (Figure 2).
Figure 2
Furthermore, a moderate inverse correlation between RNFL thickness and the duration of SLE (R: ā0.364; pāÆ=āÆ0.029) was found (Figure 3), while no correlation was observed between RNFL thickness and age (R: ā0.020; pāÆ=āÆ0.868) (Figure 4). This finding suggests that SLE may contribute to the thinning of the RNFL, potentially indicating damage over time.
Figure 3
Figure 4
The multivariate linear regression analysis presented in Table 5 demonstrates an association between CCT and the presence of SLE in the unadjusted model (pāÆ=āÆ0.027), which persisted after multivariate adjustment (pāÆ=āÆ0.024), indicating that the effect of SLE on CCT was not influenced by other variables. Furthermore, the MD in CCT between the SLE and the healthy control groups increased to 19.61āÆĪ¼m after adjustment.
Table 5
| Unadjusted | Adjusted Multivariate | ||||||
|---|---|---|---|---|---|---|---|
| Coefficient | Error | p-value | Coefficient | Error | p-value | ||
| Intercept | 517.57 | 5.95 | <0.001 | 1100.24 | 220.75 | <0.001 | |
| SLE group | Yes | 18.87 | 8.36 | 0.027 | 19.61 | 8.46 | 0.024 |
| Sex | Woman | 1.35 | 11.10 | 0.903 | |||
| Age | ā0.56 | 0.32 | 0.088 | ||||
| IOP | 3.38 | 1.47 | 0.039 | ||||
| Sphere | NS | ||||||
| Cylinder | NS | ||||||
| Schirmer 2 | NS | ||||||
| RNFL | NS | ||||||
Multivariate linear regression for CCT.
SLE, systemic lupus erythematosus; IOP, intraocular pressure; RFNL, retinal nerve fiber layer; NS, non-significant.
Discussion
Ocular manifestations are present in up to 30% of patients with SLE (1, 5), with a special vulnerability of the cornea given its composition (4, 8). A limited number of studies have looked into the relationship between SLE and CCT (4ā6, 8ā11) reporting conflicting results.
Our study aimed to assess the relationship between CCT and SLE. This is of clinical relevance as changes in CCT can influence the diagnosis of several pathologies, as thinner CCT is an independent risk factor for glaucoma development (15). We identified an association between SLE and CCT, with SLE patients presenting a significantly thicker CCT compared to healthy controls (536.44āÆĀ±āÆ39.91āÆĪ¼m vs. 517.57āÆĀ±āÆ29.62āÆĪ¼m, pāÆ=āÆ0.014). This association remained significant after adjustment (pāÆ=āÆ0.024), with the multivariate linear regression revealing a mean difference (MD) increase in CCT from 18.87 to 19.61āÆĪ¼m.
Our findings align with the findings of Zhang et al. (9) and ĆaÄlayan et al. (10). Zhang et al. did not directly measure CCT but rather corneal hysteresis (CH), inferring an association with CCT based on previous studies. They reported higher CH in SLE patients, which is positively correlated with CCT and suggests a thicker CCT in SLE patients (9). However, this contrasts with the findings of Gaspar et al. (16), who reported that the relationship between CCT and CH remains unclear and variable depending on whether the patients are glaucomatous or healthy (16).
Conversely, other studies such as Yazici et al. (4), Mahendradas et al. (8), Eissa et al. (6), Kaya et al. (11), and Mahmoud et al. (5) report a reduced CCT in SLE patients compared to controls (4ā6, 8ā11).
In our correlation analysis, we observed a moderate positive correlation between CCT and time of HCQ usage (R: 0.357; pāÆ=āÆ0.041), with a trend of increased CCT with prolonged use, peaking approximately 100āÆmonths before stabilization. No correlation was detected between the duration of SLE nor the time since the last SLE flare (R: 0.102; pāÆ=āÆ0.554 and R: 0.199; pāÆ=āÆ0.244, respectively). These findings suggest that the observed increase in CCT with longer HCQ use is independent of the duration of SLE. Given that HCQ is commonly prescribed for SLE patients (3, 13, 22) and subject to ophthalmologic follow-up, several studies have investigated its long-term ocular effects. ĆaÄlayan et al. found a significantly lower endothelial cell density (ECD) in HCQ-treated patients, with no differences in hexagonal cell percentage and no correlation between cumulative HCQ doses and ECD or CCT (10). These results are consistent with OÄurel et al., although only four patients with SLE were included in their study (23). Conversely, Vural et al. found no changes in ECD or CCT with HCQ usage but identified a negative correlation between the duration of HCQ use and corneal cell hexagonality (13). Consequently, the effects of HCQ on the cornea remain unclear, and further investigations are needed to elucidate the underlying mechanisms.
In addition, we found a moderate inverse correlation between the RNFL thickness and SLE duration (R: ā0.364; pāÆ=āÆ0.029), independent of age (R: ā0.020; pāÆ=āÆ0.868), suggesting that SLE may contribute to RNFL thinning, potentially increasing the risk of glaucoma. Furthermore, a moderate inverse correlation was identified between CCT and Raynaudās phenomenon (R: ā0.405; pāÆ=āÆ0.014), which could indicate a heightened glaucoma risk in SLE patients with Raynaudās, although no significant correlation was found between RNFL thickness and Raynaudās phenomenon (R: 0.004; pāÆ=āÆ0.983). The reported glaucoma prevalence in SLE patients in our cohort (2.8%) is similar to the published literature (3%) (24).
Glaucoma is the leading cause of irreversible blindness worldwide (25) and the second leading cause in Europe (26), with 111.8 million people expected to be affected by 2040 (25). Since glaucoma is typically asymptomatic until advanced stages, nearly 50% of cases go undiagnosed (26). While the etiology remains unclear, elevated IOP is the primary risk factor (16, 26), making accurate IOP and CCT evaluation crucial in clinical practice.
Precise and reproducible pachymetric measurements are essential, as a 40āÆĪ¼m decrease in CCT increases the relative risk of developing glaucoma by 1.71, and a 10% variation in CCT is associated with changes of 3ā4āÆmmHg in IOP (15). Our study identified a moderate positive correlation between CCT and IOP, highlighting the potential for overestimated IOP values in SLE patients with increased CCT. This may contribute to diagnostic uncertainty when distinguishing true glaucomatous changes from those related to corneal thickening. Furthermore, the correlation between CCT and long-term HCQ therapy underscores HCQās impact on corneal properties, potentially contributing to CCT thickening and complicating IOP interpretation and glaucoma risk stratification.
SLE patients are also vulnerable to optic nerve damage. In our study, RNFL thinning was observed in three SLE patients, with one showing glaucomatous visual field defects leading to a glaucoma diagnosis. Notably, RNFL thinning was correlated with SLE disease duration, underscoring the importance of differentiating glaucomatous damage from optic nerve changes due to SLE progression.
Although ultrasound pachymetry (USP) is considered the gold standard for measuring CCT (19, 20), its use can be problematic. Accuracy requires the precise placement of the probe in the central cornea, with no movement or applied pressure. In addition, corneal hydration can influence measurements in USP (15). This leads to low reproducibility and potential inaccuracies (15, 19). The quantification of CCT through corneal OCT can offer advantages over USP, including faster measurement acquisition, a reduced need for patient cooperation, and eliminating the need for topical anesthesia, thus eliminating the risks of epithelial damage, corneal deformation, and potential ocular contamination (19). Corneal OCT has demonstrated a high reproducibility and is considered interchangeable with USP (19). Its high reproducibility, combined with its routine application in other ophthalmic assessments such as RNFL evaluation, makes OCT a practical and efficient tool for comprehensive eye care. Moreover, utilizing a single device for multiple assessments simplifies the diagnostic process and aligns with the increasing demand for efficient, less invasive, patient-centered care.
Our research aims to improve methodological rigor compared to previous studies by determining representative sample size and exclusively enrolling SLE patients to enhance participant homogeneity. Several prior studies exhibited substantial variability in sample sizes and provided no a priori sample size calculation. For instance, the studies by Mahendradas et al. and OÄurel et al. included small samples of seven and four SLE patients, respectively (8, 23), limiting their analyses to descriptive statistics, similar to Mahendradas et al. (8), or necessitating the inclusion of both eyes in the analysis, as done by Mahmoud et al. (5). In addition, some studies such as those by Mahendradas et al. (8) included patients with both active and inactive SLE. In contrast, others, such as Yazici et al., Zhang et al., and Mahmoud et al., did not specify the SLE activity status (4, 5, 9). In contrast, Eissa et al. focused exclusively on active SLE patients (6), whereas the studies by Kaya et al. and ĆaÄlayan et al. examined only patients with inactive SLE (10, 11).
Moreover, we ensure the correct diagnosis of SLE because the patients were diagnosed and referred by a rheumatologist, which guarantees its accuracy and reliability. In addition, a concordance analysis was performed using the kappa index to assess the consistency of measurements in both eyes, resulting in a perfect correlation (KāÆ=āÆ1) between both eyes. Due to this, only one eye per patient was included; the eye to be included was randomly selected, contrary to previous investigations, where the choice of the eye analyzed was chosen by convention without exploring whether there were differences between both eyes. Furthermore, to minimize potential confusion bias and possible interactions, a multivariate analysis was performed. To minimize measurement bias, primary outcome data were collected through clinical interviews and tests using calibrated and validated devices. The main study variable depended on an objective test, and all participants, regardless of their assigned group, were evaluated in the same manner by the same investigator, ensuring no differences in assessments between groups.
However, our study presents some potential limitations. First, the initial uncertainty about the appropriate sample size required a pilot study, and the consecutive sampling method may limit the representativeness and generalizability of the conclusion. Second, the cross-sectional study design lacks a temporal sequence, thereby demonstrating association but not causality. Another consideration is that Zeiss Cirrus HD-OCT 5000 measures CCT from the tear film to Descemetās membrane (19), potentially reducing accuracy in patients with ocular surface disorders, such as low tear production or a diminished tear meniscus. To mitigate this, the Schirmer 2 test identified at-risk patients, and preservative-free artificial tears were applied to all participants before pachymetry. Nevertheless, the Cirrus HD-OCT review software automatically identified and measured corneal epithelial thickness as the distance between the midpoint of the first hyperreflective line, corresponding to the tear film, and the second hyperreflective line, representing the anterior surface of Bowmanās membrane. This methodology minimizes the inclusion of the tear film in the CET measurement, ensuring more precise results (20). Finally, given the absence of an initial CCT evaluation, the temporal stability of CCT once the SLE has been diagnosed is unknown, and the unexpected results contradicting our hypothesis regarding CCT decrease in SLE may be attributed to HCQ usage and its corneal deposition. To address these issues, a prospective study will be conducted to reassess CCT in SLE patients 5āÆyears after baseline CCT examination.
It is also important to acknowledge a potential selection bias among the healthy group, as participants are selected based on the absence of an established SLE diagnosis, without additional confirmation through complementary tests. However, according to the Spanish Society of Rheumatologyās EPISER study, which included 4,900 participants to determine the national prevalence of different rheumatic diseases in Spain, 12 cases of SLE were identified through a telephone interview screening. Out of these, 11 cases had an established diagnosis before the screening, with only one patient being diagnosed de novo (27). Given the estimated low prevalence of SLE, the likelihood of misclassifying patients without self-reported or documented SLE in their medical history is low.
Understanding the association between CCT and SLE could enhance ophthalmologic care and improve the quality of life for patients. These findings underscore the importance of incorporating CCT evaluation into the routine ophthalmologic assessment of SLE patients, particularly in the context of glaucoma screening and systemic disease monitoring. Collaboration between ophthalmologists, rheumatologists, and researchers is crucial for exploring underlying mechanisms, such as inflammation, immune response, and the role of HCQ. This multidisciplinary approach could shed light on the behavior of the cornea in the context of SLE. However, further research is needed to fully elucidate the underlying mechanisms and their clinical implications.
Conclusion
In conclusion, we established a significant association between CCT and the presence of SLE, with SLE patients showing significantly higher mean CCT values compared to controls. This increase may be attributed to long-term HCQ use, as CCT shows a rising trend with prolonged HCQ usage, peaking approximately 100āÆmonths before stabilization. These findings have important clinical implications for IOP assessment, glaucoma risk evaluation, and refractive surgery planning in SLE patients and those on HCQ therapy. Further prospective studies are warranted to validate these observations and explore the underlying mechanisms.
Statements
Data availability statement
The raw data supporting the conclusions of this article will be made available by the authors without undue reservation.
Ethics statement
The studies involving humans were approved by Institutional Review Board (IRB) of the General University Hospital of Elda. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.
Author contributions
JS-G: Conceptualization, Data curation, Funding acquisition, Investigation, Methodology, Project administration, Writing ā original draft, Writing ā review & editing. MC-C: Formal analysis, Writing ā original draft, Writing ā review & editing. VG-G: Conceptualization, Methodology, Project administration, Supervision, Writing ā original draft, Writing ā review & editing. MA-B: Conceptualization, Project administration, Resources, Supervision, Writing ā original draft, Writing ā review & editing. FS: Conceptualization, Methodology, Project administration, Resources, Supervision, Writing ā original draft, Writing ā review & editing.
Funding
The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. Navarro-Tripodi Foundation has provided financial support to the authors for the publication of this article.
Acknowledgments
The authors thank all study participants for their interest and cooperation.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declare that no Gen AI was used in the creation of this manuscript.
Publisherās note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2025.1545415/full#supplementary-material
References
1.
DammaccoR. Systemic lupus erythematosus and ocular involvement: an overview. Clin Exp Med. (2018) 18:135ā49. doi: 10.1007/s10238-017-0479-9
2.
LimSSDrenkardC. Epidemiology of lupus: an update. Curr Opin Rheumatol. (2015) 27:427ā32. doi: 10.1097/BOR.0000000000000198
3.
AringerMCostenbaderKDaikhDBrinksRMoscaMRamsey-GoldmanRet al. 2019 European league against rheumatism/American College of Rheumatology classification criteria for systemic lupus erythematosus. Arthritis Rheumatol. (2019) 71:1400ā12. doi: 10.1002/art.40930
4.
YaziciAKaraNYükselKAltinkaynakHBazOBozkurtEet al. The biomechanical properties of the cornea in patients with systemic lupus erythematosus. Eye (Lond). (2011) 25:1005ā9. doi: 10.1038/eye.2011.99
5.
MahmoudMSE-DHamidMAAbdelkaderMF. Anterior segment optical coherence tomography of tear film and cornea in systemic lupus erythematosus patients. Clin Ophthalmol. (2021) 15:3391ā9. doi: 10.2147/OPTH.S323673
6.
EissaIMNassarGAArfeenSADahabAA. Evaluation of central and peripheral corneal thicknesses in patients with systemic lupus erythematosus. Clin Ophthalmol. (2020) 14:589ā95. doi: 10.2147/OPTH.S234568
7.
ModrzejewskaMOstanekLBobrowska-SnarskaDKarczewiczDWilkGBrzoskoMet al. Ocular circulation in systemic lupus erythematosus. Med Sci Monit. (2009) 15:CR573ā8.
8.
MahendradasPFrancisMValaRGowdaPKawaliAShettyRet al. Quantification of ocular biomechanics in ocular manifestations of systemic autoimmune diseases. Ocul Immunol Inflamm. (2019) 27:1127ā37. doi: 10.1080/09273948.2018.1501491
9.
ZhangBShweikhYKhawajaAPGallacherJBauermeisterSFosterPJ. Associations with corneal hysteresis in a population cohort: results from 96 010 UK biobank participants. Opththalmology. (2019) 126:1500ā10. doi: 10.1016/j.ophtha.2019.06.029
10.
ĆaÄlayanMAkyolLBalcıMAĆncülHAlakuÅMFDaÄU. Evaluation of corneal safety in systemic lupus erythematosus patients undergoing long-term hydroxychloroquine treatment. Cutan Ocul Toxicol. (2021) 40:21ā5. doi: 10.1080/15569527.2020.1861003
11.
KayaHKarasuUMartinĆTaÅƧiMPekelG. Measurements of scleral thickness and corneal optic densitometry in patients with systemic lupus erythematosus. Medicine (Baltimore). (2020) 99:e21467. doi: 10.1097/MD.0000000000021467
12.
FanouriakisAKostopoulouMAndersenJAringerMArnaudLBaeS-Cet al. EULAR recommendations for the management of systemic lupus erythematosus: 2023 update. Ann Rheum Dis. (2024) 83:15ā29. doi: 10.1136/ard-2023-224762
13.
VuralEHazarLErolK. The effect of long-term hydroxychloroquine use on the corneal endothelium in patients with systemic lupus erythematosus. Int Ophthalmol. (2020) 41:937ā43. doi: 10.1007/s10792-020-01649-1
14.
American Academy of Ophthalmology. Basic and clinical science course section 8 external disease and cornea. 2022ā2023 ed. San Francisco: American Academy of Ophthalmology (2022).
15.
PierroLIulianoLGagliardiMAmbrosiARamaPBandelloF. Central corneal thickness reproducibility among ten different instruments. Optom Vis Sci. (2016) 93:1371ā9. doi: 10.1097/OPX.0000000000000974
16.
GasparRAbegĆ£o PintoLCordeiroSD. Corneal properties and glaucoma: a review of the literature and meta-analysis. Arq Bras Oftalmol. (2017) 80:202ā6. doi: 10.5935/0004-2749.20170050
17.
TranchinaLLombardoMOddoneFSerraoSSchiano LomorielloDDucoliP. Influence of corneal biomechanical properties on intraocular pressure differences between an air-puff tonometer and the Goldmann applanation tonometer. J Glaucoma. (2013) 22:416ā21. doi: 10.1097/IJG.0b013e31824cafc9
18.
SaldaƱa-GarridoJDC-CMGil-GuillƩnVFAlfaro-BeltrƔMLSiveraF. Association between central corneal thickness and systemic lupus erythematosus: a cross-sectional study protocol. Front Med. (2024) 11:11. doi: 10.3389/fmed.2024.1483930
19.
Calvo-SanzJARuiz-AlcocerJSanchez-TenaMA. Accuracy of cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness. J Optom. (2018) 11:192ā7. doi: 10.1016/j.optom.2016.12.004
20.
BaghdasaryanETepelusTCMarionKMBagheriniaHSaddaSRHsuHY. Evaluation of corneal epithelial thickness imaged by high definition optical coherence tomography in healthy eyes. Cornea. (2019) 38:62ā6. doi: 10.1097/ICO.0000000000001745
21.
BaghdasaryanEHuangXMarionKMTepelusTCBagheriniaHSaddaSRet al. Reproducibility of central corneal thickness measurements in Normal eyes using the Zeiss cirrus 5000 HD-OCT and Pentacam HR. Open Ophthalmol J. (2018) 12:72ā83. doi: 10.2174/1874364101812010072
22.
TalYMaoz SegalRLangevitzPKivitySDarnizkiZAgmon-LevinN. Hydroxychloroquine desensitization, an effective method to overcome hypersensitivity-a multicenter experience. Lupus. (2018) 27:703ā7. doi: 10.1177/0961203317735185
23.
OÄurelTĆzerMAAkbulutYGƶkƧınarNBOnaranZUretenK. Corneal thickness and endothelial changes in long-term hydroxychloroquine use. Cutan Ocul Toxicol. (2019) 38:286ā9. doi: 10.1080/15569527.2019.1608228
24.
CarliLTaniCQuerciFDella RossaAVagnaniSBaldiniCet al. Analysis of the prevalence of cataracts and glaucoma in systemic lupus erythematosus and evaluation of the rheumatologists' practice for the monitoring of glucocorticoid eye toxicity. Clin Rheumatol. (2013) 32:1071ā3. doi: 10.1007/s10067-013-2214-6
25.
ThamY-CLiXWongTYQuigleyHAAungTChengC-Y. Global prevalence of Glaucoma and projections of Glaucoma burden through 2040. A systematic review and Meta-analysis. Ophthalmology. (2014) 121:2081ā90. doi: 10.1016/j.ophtha.2014.05.013
26.
European Glaucoma Society. Terminology and guidelines of Glaucoma. Savona: PubliComm (2021).
27.
2016 GdTdPE. Lupus Eritemasoso SistĆ©mico In: ReumatologĆa FEd, editor. EPISER 2016: Estudio de prevalencia de las enfermedades reumĆ”ticas en población adulta en EspaƱa. Madrid: Sociedad EspaƱola de ReumatologĆa (2018). 79ā88.
Summary
Keywords
systemic lupus erythematosus, central corneal thickness, pachymetry, optical coherence tomography, glaucoma, hydroxychloroquine
Citation
Saldaña-Garrido JD, Cantó-CerdÔn M, Gil-Guillén VF, Alfaro-BeltrÔ ML and Sivera F (2025) Analysis of central corneal thickness in systemic lupus erythematosus. Front. Med. 12:1545415. doi: 10.3389/fmed.2025.1545415
Received
14 December 2024
Accepted
11 February 2025
Published
28 February 2025
Volume
12 - 2025
Edited by
Xin Qi, Central South University, China
Reviewed by
Eirini-Kanella Panagiotopoulou, Democritus University of Thrace, Greece
Wei Wang, Huazhong University of Science and Technology, China
Updates
Copyright
© 2025 Saldaña-Garrido, Cantó-CerdÔn, Gil-Guillén, Alfaro-BeltrÔ and Sivera.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Juan David SaldaƱa-Garrido, jdsalga@hotmail.com
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.