Ventilation Heterogeneity Across A-B-E Phenotypes in COPD: Insights from Spirometry and Electrical Impedance Tomography

Provisionally accepted
  • 1Department of Pulmonary and Critical Care Medicine, Xijing Hospital, Fourth Military Medical University, Xi’an, China
  • 2Nanshan School, Guangzhou Medical University, Guangzhou, China
  • 3Department of Biomedical Engineering, The Fourth Military Medical University, Xi’an, China
  • 4Department of Aerospace Medicine, the Fourth Military Medical University, Xi’an, China
  • 5School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China

The final, formatted version of the article will be published soon.

Purpose This study aimed to evaluate the regional ventilation distributions in A-B-E phenotypes among patients with chronic obstructive pulmonary disease (COPD). The feasibility to better distinguish the phenotypes combining global spirometry and regional ventilation parameters derived from electrical impedance tomography (EIT) was explored. Methods A cohort undergoing pulmonary function testing was prospectively enrolled. Regional spatial and temporal ventilation parameters were calculated with EIT. Principal component analysis was used to visualize phenotypic clustering, while multinomial logistic regression evaluated discriminatory performance. Feature importance was interpreted using SHapley Additive exPlanations (SHAP). Results This study enrolled 88 COPD patients (Group A n=36, Group B n=21, Group E n=31). Spirometry and EIT parameters revealed significant intergroup differences in FEV₁%pred (P < 0.001), FEV₁/FVC (P < 0.001), GI-FEV₁ (regional distribution of FEV1%pred in functional EIT; P = 0.004), GI-FEV₁/FVC (regional distribution of FEV₁/FVC; P = 0.001) and expiratory time constant (P = 0.017). Group A demonstrated the best pulmonary function (FEV₁%pred: 77.67±20.40), while Group E showed the most pronounced flow limitation (longest time required to exhale 75% of FVC, T75). The multinomial model showed optimal discrimination for Group A (AUC: 0.827), while differentiation between Groups B and E was less satisfactory (AUC: 0.749). SHAP analysis identified FEV₁%pred as the most significant predictor (|SHAP|=0.477), with EIT-derived parameters GI-FEV₁/FVC (|SHAP|=0.203) and regional T75 (|SHAP|=0.189) providing substantial incremental value. Conclusions COPD phenotypes showed differences in global and regional flow limitations. The combination of global and regional information helped with distinguishing phenotypes.

Keywords: Electrical impedance tomography, chronic obstructive pulmonary disease, ABE Phenotype Classification, Multiclass Logistic Regression Model, Regional ventilation

Received: 24 Oct 2025; Accepted: 12 Nov 2025.

Copyright: © 2025 Zhang, Liu, Chang, Dai, Song, Yang, Ti, Qu and Zhao. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

* Correspondence:
Lin Yang, yanglin.0601@163.com
Xinyu Ti, ti_xinyufmmu@126.com
Shuoyao Qu, qsy129@fmmu.edu.cn

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.