Ultrasound Biomicroscopic Imaging Analysis of Lens Position and Stability in Acute and Chronic Angle-Closure Glaucoma

Provisionally accepted
Zhiying  YuZhiying YuXinyu  WangXinyu WangHaitao  WangHaitao WangJing  HanJing HanJing  FuJing FuLicun  WangLicun WangLing  WangLing Wang*
  • The Affiliated Hospital of Qingdao University, Qingdao, China

The final, formatted version of the article will be published soon.

This study aimed to compare the characteristics and differences in lens position and stability in patients with acute and chronic angle-closure glaucoma (ACG) using ultrasound biomicroscopy (UBM) to provide a basis for selecting treatment regimens for primary ACG (PACG).Methods: This prospective study included 82 eyes of patients with PACG, of which, 45 eyes with acute PACG (APACG), 37 with chronic PACG (CPACG). Axial length (AL) and lens thickness (LT) were measured using A-scan ultrasonography. Anterior chamber depth (ACD), pupil diameter (PD), and lens vault (LV) were measured using UBM for each group. Additionally, trabecular-iris angle (TIA), angle opening distance (AOD 500 ), iris-lens angle (ILA), and iris-lens contact distance (ILCD) were measured in four quadrants (superior, inferior, nasal, and temporal) with UBM. The corresponding lens position (LP), relative lens position (RLP), and lens thickness/axial length factor (LAF) were calculated. Normally distributed data were compared between the two groups using an independent samples t-test. Data that did not follow a normal distribution were compared using the Mann-Whitney U test.Differences were considered statistically significant when P < 0.05, and they were considered highly statistically significant when P < 0.01.The values for angle-related parameters, including the mean TIA, TIA max-min , mean AOD 500 , AOD 500 max-min , and ACD, were significantly lower in the APACG group than in the CPACG group (all P < 0.05). The LP and RLP values of the APACG group were also lower than those of the CPACG group, but only the difference in LP values being statistically significant (P = 0.038). The LT, LV, LAF, mean ILCD, and ILCD max-min values were higher than those of the CPACG group, with the differences reaching statistical significance (all P < 0.05).The APACG eyes had a thicker and more-anteriorly positioned lens than those with CPACG, which results in a shallower anterior chamber and narrower anterior chamber angle. In the APACG group, the lens exhibited nonuniform laxity of the suspensory ligament across the various quadrants, poor stability, and greater susceptibility for anterior displacement or even deviation.

Keywords: Acute angle-closure glaucoma, Chronic angle-closure glaucoma, Ultrasound biomicroscopy, Lens position, Suspensory ligament

Received: 08 May 2025; Accepted: 13 Jun 2025.

Copyright: © 2025 Yu, Wang, Wang, Han, Fu, Wang and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

* Correspondence: Ling Wang, The Affiliated Hospital of Qingdao University, Qingdao, China

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.