Abstract
Introduction:
The role of reverse trigger (RT) was unknown in ventilated non-acute respiratory distress syndrome (ARDS) patients. So we conducted a retrospective study to evaluate the incidence, characteristics and physiologic consequence of RT in such population.
Method:
Six ventilated non-ARDS patients were included, the esophageal balloon catheter were placed for measurements of respiratory mechanics in all patients. And the data were analyzed to identified the occurrence of RT, duration of the entrainment, the entrainment pattern or ratio, the phase difference (dP) and the phase angle (θ), phenotypes, Effects and clinical correlations of RT.
Result:
RT was detected in four patients of our series (66.7%), and the occurrence of RT varying from 19 to 88.6% of their recording time in these 4 patients. One patient (No.2) showed a stable 1:1 ratio and Mid-cycle RT was the most common phenotype. However, the remained patients showed a mixed ratios, and Late RT was the most common phenotype, followed by RT with breath stacking. The average values of mean phase delay and phase angles were 0.39s (0.32, 0.98) and 60.52° (49.66, 102.24). Mean phase delay and phase angles were shorter in early reverse triggering with early and delayed relaxation, and longer in mid, late RT and RT with breath stacking. Pmus was variable between patients and phenotypes, and larger Pmus was generated in Early RT, Delayed Relaxation and mid cycle RT. When the RT occurred, the Peso increased 17.27 (4.91, 19.71) cmH2O compared to the controlled breathing, and the average value of incremental ΔPeso varied widely inter and intra patients (Table 3B and Figure 1). Larger ΔPeso was always generated in Early RT, Delayed Relaxation and mid cycle RT, accompanied by an significant increase of PL with 19.12 (0.75) cmH2O and 16.10 (6.23) cmH2O.
Conclusion:
RT could also be observed in ventilated non-ARDS patients. The characteristics of pattern and phenotype was similar to RT in ARDS patients to a large extent. And RT appeared to alter lung stress and delivered volumes.
Background
Since the research published by Akoumianaki (), the term “reverse trigger (RT)” has attracted the attention of the intensivist in the worldwide (; ; ; ). Reverse trigger is a type of patient-ventilator dyssynchrony whereby a diaphragm muscle contraction occurs after a mandatory breath initiated by the ventilator (). In Brief, RT indicates an activity of the diaphragm triggered by a ventilator mediated insufflation of the thorax. In a very recent retrospective study (), Kassis et al. have further described the phenotypes of this phenomenon in details. However, almost all the articles related to RT in critically ill focused on the ventilated acute respiratory distress syndrome (ARDS) patients, and the role of this term in ventilated non-ARDS patients remains unknown. in respiratory physiology, the concept of RT is based on the “respiratory entrainment,” which refers to the establishment of a fixed repetitive temporal relationship between the neural and mechanical respiratory cycles (). Several studies have revealed that the respiratory rhythm can be entrained or phase locked to extrinsic periodic mechanical inflations imposed during controlled mechanical ventilation (; ; ). Therefore we purposed that this phenomenon is also available in other ventilated non-ARDS patients, as these patients also interact with the energy system of the ventilator.
We observed the phenomenon of RT in a sedated ventilated lung transplant patient with a continuous esophageal pressure (Pes) recording occasionally. After that, we retrospectively collected and analyzed available data of other ventilated non-ARDS patients. This case series may represent the first description of RT in such population, and this study aims to evaluate the incidence, pattern and phenotypes of RT and explore changes in esophageal pressure (Peso) and transpulmonary pressure (PL) with these efforts in such population.
Methods
Study Population
A retrospective study was conducted in a 37 beds general ICU in the 1st affiliated hospital of Guangzhou Medical University. And the analysis was performed on 6 patients from another ongoing trail with acute respiratory failure, which was approved by the Ethics Committee of the First Affiliated Hospital of Guangzhou Medical University (Approval No.2020-065) and the informed consent were obtained from all the patient’s families.
Data Acquisition
Six patients were ventilated and all of them had an esophageal balloon catheter placed for measurements of respiratory mechanics. DP15 pressure transducers (Validyne Engineering Corp., United States) were respectively connected to the esophageal balloon and the respiratory circuit and were used to record pressures traces (Paw, Peso). The pressure transducers were connected to a CD280 pressure amplifier (Validyne Engineering Corp., United States). The pressure signals ultimately were recorded by PowerLab Data Recording and Analysis system (Powerlab 16/30 SP, ADInstruments Pty Ltd, Australia). The sampling rate was 200 Hz. Transpulmonary pressure (PL) equal to Paw minus Peso. The Paw, Peso, PL were displayed simultaneously. The data were stored in a notebook and were analyzed using commercially available software (labchart7.0, ADinstrucments Pty Ltd, Australia).
The Definition of Terms
Patient inspiratory effort was detected through the Peso negative fluctuation from baseline. The definition of RT and the following descriptive parameters such as the duration of the entrainment, the entrainment pattern or ratio, the phase difference (dP) and the phase angle (θ) were according to the previous research (). RT was defined by a sudden negative fluctuation of Peso occurring after the onset of a mandatory breath. RT were divided into 5 phenotypes:(1) Early RT, Early Relaxation; (2) Early RT, Delayed Relaxation; (3) Mid Cycle RT; (4) Late RT and (5) RT with Breath stacking, the definition were according to another previous research (), and modified through peer-review to clarify definitions.
Statistical Methods
Data were analyzed by descriptive statistical methods and are expressed as mean ± SD, medians, and the IQR. Statistical analysis was carried out by SPSS 17.0 software.
Results
Patient’s Characteristics
Recordings of Pes were available in six patients, who were deeply sedated due to clinical condition. And all of them were ventilated by Evita XL (Dräger), the ventilator mode was either volume assist-control (VAC) or pressure assist-control. More details of patient’s demography, diagnosis, ventilator and respiratory mechanisms were shown in Table 1.
TABLE 1
| Patient No. | Age, years | Gender | Diagnosis | Mode | RR | VT,mL/kg IBW | Peak, cm H2O | PEEP, cm H2O | Timech, s | Crs, mL/cm H20 | Rrs, cm H20/L/s, |
| 1 | 67 | F | Interstitial Pneumonia | VAC | 16 | 2.85 | 20 | 5 | 0.95 | 12.2 | 14.5 |
| 2 | 30 | M | Obliterans Bronchitis | VAC | 26 | 5.6 | 40 | 2 | 0.8 | 30 | 35 |
| 3 | 59 | F | Bilateral lung transplantation | VAC | 16 | 5.2 | 18 | 2 | 0.9 | 20.6 | 13.6 |
| 4 | 75 | F | Sepsis | VAC | 19 | 8.4 | 22 | 6 | 0.95 | 54 | 14.4 |
| 5 | 58 | F | Bilateral lung transplantation | VAC | 17 | 4.1 | 23 | 8 | 0.95 | 14.8 | 19.7 |
| 6 | 65 | M | Bronchiectasis | VAC | 17 | 6 | 21 | 5 | 1.0 | 45.9 | 13.7 |
Patient’s demography, diagnosis, ventilator and respiratory mechanics.
F, female; M, male; PAC, pressure assist-control; VAC, volume assist-control; RR, respiratory rate; VT, tidal volume; IBW, ideal body weight; PEEP, positive end-expiratory pressure; Timech, mechanical inspiratory time; Crs, respiratory system compliance; Rrs, respiratory system resistance.
Reverse Trigger Characteristics
All patients were deeply sedated indicated as RASS score −5. We analyzed waveform data consisted of an average of 7.3 ± 1.14 min per patient for a total of 52.1 min and 971 breaths. Reverse trigger events were detected in 448 total breaths (46.1%) in 4 patients (66.7%) (No. 2, 3, 4, 6), and the occurrence of reverse trigger varying from 19 to 88.6% of their recording time in these 4 patients. Blinded review of phenotypes resulted in 100% agreement, More details were shown in Table 2.
TABLE 2
| Patient No. | RASS | RRrecord | RRRT | RRRT/RRrecord% | P/F, mm Hg | FiO2, % | PH | PaCO2 | HCO3- | BE |
| 1 | −5 | 154 | 0 | 0 | ECMO support | 40 | 7.449 | 46.7 | 32.5 | 7.6 |
| 2 | −5 | 290 | 257 | 88.6 | 204 | 50 | 7.379 | 72.5 | 41.8 | 15 |
| 3 | −5 | 150 | 29 | 19 | ECMO support | 50 | 7.391 | 38.7 | 27.4 | −1.7 |
| 4 | −5 | 140 | 72 | 51.4 | 220 | 55 | 7.419 | 44.5 | 27.2 | 2.8 |
| 5 | −5 | 146 | 0 | 0 | ECMO support | 80 | 7.416 | 44.3 | 27.9 | 3.6 |
| 6 | −5 | 124 | 82 | 66.1 | 298 | 50 | 7.473 | 43 | 30.9 | 7.1 |
Patient’s sedation level, total recording respirations, reverse trigger duration and ratio, and arterial blood gases results.
RASS, Richmond Agitation-Sedation Scale; RRrecord, Recorded respirations; RRRT, respirations with reverse trigger; ECMO, extracorporeal membrane oxygenation; P/F, PaO2 to FiO2 ratio.
One patient (No.2) showed a stable 1:1 ratio and Mid-cycle RT was the most common phenotype. However, the remained patients showed a mixed ratios, and Late RT was the most common phenotype, followed by RT with Breath stacking, more details were shown in Table 3A and Figures 2, 3.
FIGURE 1
TABLE 3A
| Patient No. | RTtype | RTtot | Early RT, early relaxation | Early RT, delayed relaxation | Mid Cycle RT | Late RT | Breath stacking |
| 2 | Stable(1:1) | 257 (100%) | 0 | 19 (7%) | 220 (86%) | 18 (7%) | 0 |
| 3 | Unstable | 29 (100%) | 0 | 0 | 2 (7%) | 19 (65.5%) | 8 (27.5%) |
| 4 | Unstable | 72 (100%) | 3 (4.2%) | 0 | 23 (31.9%) | 30 (41.7%) | 16 (22.2%) |
| 6 | Unstable | 82 (100%) | 0 | 0 | 0 | 57 (69.5%) | 25 (30.5%) |
Phenotypes of reverse trigger.
RTtype, type of reverse trigger; RTtot, total numbers of reverse trigger.
TABLE 3B
| Patient No. | Phase delay, dP, s | Phase angle, θ, degree | ΔPeso, cmH2O | |||
| Median | IQR | Median | IQR | Median | IQR | |
| 2 | 0.33 | (0.3, 0.38) | 51.21 | (46.55, 58.97) | 19.5 | (18.21, 21.12) |
| 3 | 0.91 | (0.89, 0.94) | 98.08 | (95.93, 101.32) | 5.9 | (4.22, 7.01) |
| 4 | 0.96 | (0.6, 1.09) | 103.87 | (65.26, 118.55) | 5.24 | (4.04, 7.76) |
| 6 | 1.10 | (1.00, 1.13) | 104.76 | (95.23, 107.62 | 2.36 | (1.30, 4.74) |
| Average | 0.39 | (0.32, 0.98) | 60.52 | (49.66, 102.24) | 17.27 | (4.91, 19.71) |
Phase delay, Phase angle and the ΔPeso during reverse trigger.
ΔPeso, the maximal inspiratory muscle pressure during reverse trigger.
FIGURE 2
FIGURE 3

Traces of Paw, PL and Pes during reverse trigger episodes. The vertical dashed line indicates an initiation of a patient effort which is express as the negative fluctuation of esophageal pressure, the arrow indicates a breath with reverse trigger. (A) Stable reverse trigger (1:1 entrainment) traces acquired in patient No.2; (B) unstable reverse trigger traces acquired in patient No.4. Paw, airway pressure; PL, transpulmonary pressure; Peso, esophageal pressure.
The average values of mean phase delay and phase angles were 0.39s (0.32, 0.98) and 60.52° (49.66, 102.24). In patient No.2, the phase angles varied widely breath by breath (Table 3B and Figure 1). Mean phase delay and phase angles were shorter in early reverse triggering with early and delayed relaxation, and longer in mid, late RT and RT with breath stacking. More details were shown in Table 3C.
TABLE 3C
| Early RT, early relaxation | Early RT, delayed relaxation | Mid cycle RT | Late RT | Breath stacking | |
| Phase delay, Mean (SD), s | 0.38 (0.16) | 0.32 (0.04) | 0.36 (0.12) | 1.04 (0.13) | 1 (0.17) |
| Phase angle, mean (SD), degree | 41.33 (16.88) | 53 (9.79) | 54.51 (17.71) | 110.65 (27.02) | 101.7 (19.76) |
| ΔPeso, mean (SD), cmH2O | 5.44 (0.50) | 18.32 (3.36) | 18.22 (4.52) | 5.66 (7.43) | 6.2 (2.29) |
| ΔPL, mean (SD), cmH2O | 1.92 (0.64) | 19.12 (0.75) | 16.10 (6.23) | −0.64 (1.26) | −0.17 (1.90) |
| PLbasline, mean (SD), cmH2O | 14.34 (5.89) | ||||
Phase delay, Phase angle and the ΔPeso, PL in each phenotypes of reverse trigger.
ΔPeso, the maximal inspiratory muscle pressure during reverse trigger; ΔPL, the maximal inspiratory transpulmonary pressure during the breath with RT minus the maximal transpiratory transpulmonary pressure during the control breath without RT. PLbaseline, the average value of maximal inspiratory transpulmonary pressure of all analyzed control breath.
Reverse Trigger Effects and Clinical Correlations
The ventilator parameters were not adjusted in entire analysis periods in all patients. in patient No.2, the dosage of sedative drug was decreased in the observational period, even though the RASS score did not change, the patient gradually appeared a transition from assist mechanical breath to intermittent (unstable) RT and stable RT (Figure 4). When the RT occurred, the Peso increased 17.27 (4.91, 19.71) cmH2O compared to the controlled breathing, and the average value of incremental ΔPeso varied widely inter and intra patients (Table 3B and Figure 1). Larger ΔPeso was always generated in Early RT, Delayed Relaxation and mid cycle RT, accompanied by an significant increase of PL with 19.12 (0.75) cmH2O and 16.10 (6.23) cmH2O. More details were shown in Table 3C and Figure 5.
FIGURE 4

Transition from assist mechanical breath to intermittent (unstable) reverse trigger and stable reverse trigger. Traces were acquired in patient No.2. Dotted line denoted the initiation of each neural breath. Panel (A) showed that each neural breath arose before a mechanical breach initiation or the phase delay > 0 (Assist breath); Panel (B) showed the coexistence of Assist breath and Control breath with stable reverse trigger. The red solid line box included two Control breath with stable reverse trigger (the 4th and 5th breath). Panel (C) showed that each neural breath arose behind a mechanical breach initiation or the phase delay < 0 (Control breath with stable reverse trigger). Paw, airway pressure; PL, transpulmonary pressure; Peso, esophageal pressure.
FIGURE 5

An overlaping display of pressure waveforms of a control breath with reverse trigger and a control breath. Traces were acquired in patient No.4; Paw, airway pressure; PL, transpulmonary pressure; Peso, esophageal pressure. The black solid lines indicates the Paw, PL and Peso fluctuations during a mandatory or control breath. The red solid lines indicates the Paw, PL and Peso fluctuations during a breath with reverse trigger in the same patient. Comparing to the control breath, arising of patient effort or delta Peso may elevates PL during breath with reverse trigger.
Discussion
To our knowledge, it is the first study to describe the phenomenon of RT in ventilated non-ARDS patients in ICU. Our study revealed that reverse trigger occurred in 4/6 of our cases, and the phenotypes of RT varied widely, followed by an increment of ΔPeso, especially in Mid cycle RT.
In our study, 2 patients (No.3 and 5) underwent bilateral lung transplantation. Primary graft dysfunction, which was a very common postoperative complication, was similar to ARDS (
Pathophysiologic mechanisms of RT remained controversial. At present the mainstream view of it was in related to the respiratory entrainment (
In the healthy subjects, several studies had demonstrated that stable entrainment ratio such as 1:1 was the most common (
We observed the breathing stacking and elevated PL in the patients when RT occurred. It was in line with the finding of Kassis’s research (
Our study had several limitations: (1) the sample size is relatively small, because it is difficult to obtain the complete data in a retrospective study. Besides, Patients included in the current study present with specific traits (three patients supported by ECMO and two lung transplant recipients). Since we observed a high incidence of RT in such population, A prospective study with a larger sample size is necessary to determine the prevalence of RT in Non-ARDS patients. (2) The data was not initiated for this investigation, so we could not clearly illustrate the mechanism, response to intervention and impact on clinical outcome of RT. It was due to nature of the retrospective study and a well-designed prospective study was needed. (3) We did not use Campbell diagram to differentiate the phenotypes of RT, which was used in Kassis’s research (
In conclusion, RT could also be observed in ventilated non-ARDS patients in ICU. The characteristics of pattern and phenotype was similar to RT in ARDS patients to a large extent. And RT appeared to alter lung stress and delivered volumes.
Publisher’s Note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Statements
Data availability statement
The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author/s.
Ethics statement
The studies involving human participants were reviewed and approved by the Ethics Committee of the First Affiliated Hospital of Guangzhou Medical University. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.
Author contributions
LS and YX had the idea for and designed the study, they had full access to all data in the study and took responsibility for the integrity of the data analysis. LS and JZ wrote the first full draft of the report. All authors contributed to data acquisition, data analysis, or data interpretation, and they all reviewed and approved the final version.
Funding
This work was supported by Emergency Key Program of Guangzhou Laboratory (Grant No. EKPG21-17), National Science and Technology Major Project (Grant No. 2017ZX10204401), the Special Project of Guangdong Science and Technology (Grant No. 2020B1111340016), the Natural Science Foundation of Guangdong Province, China (Grant Nos. 2020A1515011459 and 2017A030313781), and National Natural Science Foundation of China (Grant No. 81870069).
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
1
AkoumianakiE.LyazidiA.ReyN.MatamisD.Perez-MartinezN.GiraudR.et al (2013). Mechanical ventilation-induced reverse-triggered breaths: a frequently unrecognized form of neuromechanical coupling.Chest143927–938. 10.1378/chest.12-1817
2
BaconnierP. F.BenchetritG.PachotP.DemongeotJ. (1993). Entrainment of the respiratory rhythm: a new approach.J. Theoret. Biol.164:149. 10.1006/jtbi.1993.1145
3
BenchetritG.MuzzinS.BaconnierP.BachyJ. P.EberhardA. (1986). “Entrainment of the respiratory rhythm by repetitive stimulation of pulmonary receptors: effect of C02,” in Neurobiology of the Control of Breathing, edsvon EulerC.LagercrantzH. (New York, NY: Raven Press), 263–268.
4
BourenneJ.GuervillyC.MechatiM.HraiechS.FraisseM.BisbalM.et al (2019). Variability of reverse triggering in deeply sedated ARDS patients.Intensive Care Med.45725–726. 10.1007/s00134-018-5500-6
5
De HaroC.López-AguilarJ.MagransR.MontanyaJ.Fernández-GonzaloS.TuronM.et al (2018). Double cycling during mechanical ventilation: frequency, mechanisms, and physiologic implications.Crit. Care Med.461385–1392. 10.1097/ccm.0000000000003256
6
FullerB. M.MohrN. M.DrewryA. M.CarpenterC. R. (2013). Lower tidal volume at initiation of mechanical ventilation may reduce progression to acute respiratory distress syndrome: a systematic review.Crit. Care17:R11.
7
GravesC.GlassL.LaportaD.MelocheR.GrassinoA. (1986). Respiratory phase locking during mechanical ventilation in anesthetized human subjects.Am. J. Physiol.250(5 Pt. 2):R902.
8
GriecoD. L.ChenL.BrochardL. (2017). Transpulmonary pressure: importance and limits.Ann. Transl. Med.5:285. 10.21037/atm.2017.07.22
9
KassisE. B.SuH. K.GrahamA. R.NovackV.LoringS. H.TalmorD. S. (2020). Reverse trigger phenotypes in acute respiratory distress syndrome.Am. J. Respir. Crit. Care Med.20367–77.
10
MauriT.GrasselliG.SurianoG.EroniaN.SpadaroS.TurriniC.et al (2016). Control of respiratory drive and effort in extracorporeal membrane oxygenation patients recovering from severe acute respiratory distress syndrome.Anesthesiology125159–167. 10.1097/aln.0000000000001103
11
Mellado ArtigasR.DamianiL. F.PirainoT.PhamT.ChenL.RauseoM.et al (2021). Reverse triggering dyssynchrony 24 h after initiation of mechanical ventilation.Anesthesiology134760–769. 10.1097/aln.0000000000003726
12
MuzzinS.BaconnierP.BenchetritG. (1992). Entrainment of respiratory rhythm by periodic lung inflation: effect of airflow rate and duration.Am. J. Physiol.263(2 Pt. 2):R292.
13
NetoA. S.NagtzaamL.SchultzM. J. (2014). Ventilation with lower tidal volumes for critically ill patients without the acute respiratory distress syndrome: a systematic translational review and meta-analysis.Curr. Opin. Crit. Care2025–32. 10.1097/mcc.0000000000000044
14
PetrilloG. A.GlassL.TrippenbachT.LeiterJ. C. (1983). Phase locking of the respiratory rhythm in cats to a mechanical ventilator.Can. J. Physiol. Pharmacol.61599–607. 10.1139/y83-092
15
RodensteinD. O.StanescuD. C.CuttitaG. (1989). Ventilatory and diaphragmatic emg responses to negative-pressure ventilation in airflow obstruction.J. Crit. Care4229–230. 10.1016/0883-9441(89)90028-2
16
SimonP. M.HabelA. M.DaubenspeckJ. A.LeiterJ. C. (2000). Vagal feedback in the entrainment of respiration to mechanical ventilation in sleeping humans.J. Appl. Physiol.89760–769. 10.1152/jappl.2000.89.2.760
17
SimonP. M.ZurobA. S.WiesW. M.LeiterJ. C.LeiterJ. C.HubmayrR. D. (1999). Entrainment of respiration in humans by periodic lung inflations. Effect of state and CO(2).Am. J. Respir. Crit. Care Med.160950–960. 10.1164/ajrccm.160.3.9712057
18
TaigaI.YoshitoyoU.NobutoN.JunO. (2018). Reverse triggering induced by endotracheal tube leak in lightly sedated ARDS patient.J. Intensive Care6:41.
19
TakeshiY.MiyukiN. M. A.MoraisC. C. A.AmatoM. B. P.KavanaghB. P. (2018). Reverse triggering causes an injurious inflation pattern during mechanical ventilation.Am. J. Respir. Crit. Care Med.1981096–1099. 10.1164/rccm.201804-0649le
20
TalaieT.DichiacchioL.PrasadN. K.PasrijaC.JulliardW.KaczorowskiD. J.et al (2021). Ischemia-reperfusion Injury in the transplanted lung: a literature review.Transplant. Direct7:e652. 10.1097/txd.0000000000001104
21
TalmorD.SargeT.MalhotraA.O’DonnellC. R.RitzR.LisbonA.et al (2008). Mechanical ventilation guided by esophageal pressure in acute lung injury.N. Engl. J. Med.3592095–2104.
22
VibertJ. F.CailleD.SegundoJ. P. (1981). Respiratory oscillator entrainment by periodic vagal afferentes: an experimental test of a model.Biol. Cybern.41119–130. 10.1007/bf00335366
23
Writing Group for the PReVENT Investigators, SimonisF. D.Serpa NetoA.BinnekadeJ. M.BraberA.BruinK. C. M. (2018). Effect of a low vs intermediate tidal volume strategy on ventilator-free days in intensive care unit patients without ards: a randomized clinical trial.JAMA 3201872–1880. 10.1001/jama.2018.14280
24
YonisH.GobertF.TapponnierR.GuérinC. (2015). Reverse triggering in a patient with ARDS.Intensive Care Med.411711–1712. 10.1007/s00134-015-3702-8
Summary
Keywords
reverse triggering, mechanical ventilation, sedation, acute respiratory distress syndrome, respiratory mechanics
Citation
Lin Z, Zhou J, Lin X, Wang Y, Zheng H, Huang W, Liu X, Li Y, Zhong N, Huang Y, Xu Y and Sang L (2021) Reverse Trigger in Ventilated Non-ARDS Patients: A Phenomenon Can Not Be Ignored!. Front. Physiol. 12:670172. doi: 10.3389/fphys.2021.670172
Received
20 February 2021
Accepted
28 June 2021
Published
29 July 2021
Volume
12 - 2021
Edited by
Peter Markus Spieth, University Hospital Carl Gustav Carus, Germany
Reviewed by
Mark Edward Wylam, Mayo Clinic, United States; Teresa Pitts, University of Louisville, United States
Updates

Check for updates
Copyright
© 2021 Lin, Zhou, Lin, Wang, Zheng, Huang, Liu, Li, Zhong, Huang, Xu and Sang.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ling Sang, sonysang999@vip.163.comYongbo Huang, yongbo2046@163.comYuanda Xu, xuyuanda@sina.com
†These authors have contributed equally to this work
This article was submitted to Respiratory Physiology, a section of the journal Frontiers in Physiology
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.