Abstract
Objective: The feasibility of the conduction system pacing (CSP) upgrade as an alternative modality to the traditional biventricular pacing (BiVP) upgrade in patients with pacemaker-induced cardiomyopathy (PICM) remains uncertain. This study sought to compare two modalities of CSP (His bundle pacing (HBP) and left bundle branch pacing (LBBP)) with BiVP and no upgrades in patients with pacing-induced cardiomyopathy.
Methods: This retrospective analysis comprised consecutive patients who underwent either BiVP or CSP upgrade for PICM at the cardiac department from 2017 to 2021. Patients with a follow-up period exceeding 12Â months were considered for the final analysis.
Results: The final group of patients who underwent upgrades included 48 individuals: 11 with BiVP upgrades, 24 with HBP upgrades, and 13 with LBBP upgrades. Compared to the baseline data, there were significant improvements in cardiac performance at the last follow-up. After the upgrade, the QRS duration (127.81 ± 31.89 vs 177.08 ± 34.35 ms, p < 0.001), NYHA class (2.28 ± 0.70 vs 3.04 ± 0.54, p < 0.05), left ventricular end-diastolic diameter (LVEDD) (54.08 ± 4.80 vs 57.50 ± 4.85 mm, p < 0.05), and left ventricular ejection fraction (LVEF) (44.46% ± 6.39% vs 33.15% ± 5.25%, p < 0.001) were improved. There was a noticeable improvement in LVEF in the CSP group (32.15% ± 3.22% vs 44.95% ± 3.99% (p < 0.001)) and the BiVP group (33.90% ± 3.09% vs 40.83% ± 2.99% (p < 0.001)). The changes in QRS duration were more evident in CSP than in BiVP (56.65 ± 11.71 vs 34.67 ± 13.32, p < 0.001). Similarly, the changes in LVEF (12.8 ± 3.66 vs 6.93 ± 3.04, p < 0.001) and LVEDD (5.80 ± 1.71 vs 3.16 ± 1.35, p < 0.001) were greater in CSP than in BiVP. The changes in LVEDD (p = 0.549) and LVEF (p = 0.570) were similar in the LBBP and HBP groups. The threshold in LBBP was also lower than that in HBP (1.01 ± 0.43 vs 1.33 ± 0.32 V, p = 0.019).
Conclusion: The improvement of clinical outcomes in CSP was more significant than in BiVP. CSP may be an alternative therapy to CRT for patients with PICM. LBBP would be a better choice than HBP due to its lower thresholds.
Introduction
Long-term right ventricular pacing has been linked to cardiac dyssynchrony and pacemaker-induced cardiomyopathy (PICM) (Sharma et al., 2020). Upgrading to biventricular pacing (BiVP) was recommended for patients who developed PICM (Gierula et al., 2013). However, BiVP procedure failure and non-response were not uncommon (Khurshid et al., 2018).
Conduction system pacing (CSP), which includes His bundle pacing (HBP) and left bundle branch pacing (LBBP) modalities, has been shown to have a positive impact on cardiac performance (Herweg et al., 2021; Bednarek et al., 2023). The benefits of CSP upgrades in patients with PICM have also been reported (Yang et al., 2021). However, whether a CSP upgrade is a feasible alternative pacing modality to a BiVP upgrade still needs to be determined. This study aims to explore the different outcomes associated with varying upgrade modalities.
Methods
Population and study design
This study is a retrospective observational study. All patients with PICM were enrolled retrospectively from 2017 to 2021 at the First Affiliated Hospital of Dalian Medical University (FAHDMU). All patients were given a chance to choose an upgrade after being informed about the criteria for optimal pacing, success rate, factors for failure, complications, technical details for lead placement, and other pacing-related details. If the patient’s first choice failed, all patients agreed to switch to the alternative therapy (CSP to BiVP or vice versa). All patients provided consent for their respective treatments. The Ethics Committee of the FAHDMU approved the study and procedures (No. PJ-KS-KY-2023-365). The patient enrollment flowchart is shown in Figure 1.
FIGURE 1
Measurements
Left ventricular end-diastolic diameter (LVEDD) and left atrial diameter (LAD) were measured based on the American Society of Echocardiography guidelines. LVEF was obtained using the biplane Simpson method. The vena contracta width with color flow Doppler was used to measure the maximum mitral regurgitation (MR) and tricuspid regurgitation (TR).
Criteria and definitions
It is important to note that PICM definitions vary in different studies. In this study, we have established the following criteria for defining PICM: LVEF ≥50% before RVP implantation, the development of new-onset heart failure in patients with RVP >40% and LVEF ≤40%, and the absence of other causes of heart failure (Tops et al., 2009; Chen et al., 2013; Udo et al., 2015; Kiehl et al., 2016; Lu et al., 2022). Additionally, patients with AV node ablations were excluded. Left bundle branch area pacing capture was defined by an abrupt decrease in the Stim-LV active time (LVAT) of more than 10 ms and less than 75 ms, along with specific morphologies in Qr, qR, or rSRʹ in lead V1. HBP was not considered if a 1:1 His ventricular conduction was not noted during pacing at 110 beats per minute. LVEF greater than 50% and LVEDD less than 50 mm were considered complete LV reverse remodeling. The CSP response was defined as an absolute increase in LVEF by ≥ 5% after 1 year (Vijayaraman et al., 2018a; Abdin et al., 2022).
Upgrading procedure
HBP and LBBP were performed using the select secure pacing lead (Model 3830, Medtronic Inc.) and a fixed-curve sheath (C315 HIS, Medtronic Inc.). His bundle electrograms were mapped in a unipolar configuration and recorded in the system (Prucka CardioLab, GE Healthcare) (Sundaram and Vijayaraman, 2020). The pacing rate was decreased to 30Â bpm for an escape rhythm. Pacing mapping was conducted if no His bundle electrogram was detected. HBP was acceptable when the capture threshold was lower than 2.0Â V/1.0Â ms (Vijayaraman et al., 2018b). LBBP would be further performed if HBP was not detected. For patients with dependent ventricular pacing, right ventricular backup pacing was routinely performed if the threshold of HBP was higher than 2.0Â v/0.5Â ms. In patients with permanent AF who required a dual-chamber pacemaker, the 3830 lead was connected to the right atrial port, and the right ventricular lead remained in the RV port. In patients who received a new CRT defibrillator (D) or CRT pacemaker (P) device, the RA lead remained in the atrial port, and the RV lead remained in the RV port as a backup. The 3830 lead was connected to the left ventricular (LV) port.
The LV lead was implanted via the traditional coronary venous approach for BiVP implants. If possible, it is positioned using a standard technique in the lateral or posterolateral LV vein in patients with BiVP.
Follow-up
All patients received optimal medical therapy for at least 3Â months prior to the procedure. All patients with PICM were followed for at least 1Â year, regardless of resynchronization upgrade. Clinical data were regularly collected for at least half a year. During the follow-up, a 12-lead electrocardiogram (ECG), echocardiography, postoperative complications, and pacemaker parameters were monitored.
Statistical analysis
Statistical analyses were performed using SPSS 27.0. Continuous variables were expressed as the mean ± SD or median and were compared with an independent two-sample, paired t-test, or Wilcoxon test. Differences among groups were assessed using analysis of variance, or Kruskal–Wallis, depending on the presence of a normal distribution. Categorical variables were expressed as numbers (%) and were compared using Fisher’s exact test. p < 0.05 (two-tailed) was considered statistically significant.
Results
Baseline characteristics
During the study period, 73 patients were initially enrolled. Of these, 23 patients refused the upgrade, 2 patients tried to undergo the upgrade but failed, and 48 patients (48/50.96%) successfully underwent a resynchronization upgrade. Of these 48 upgraded patients, 24 received HBP, 13 received LBBP, and 11 received BiVP. During the procedure, two patients switched to LBBP due to a high threshold of over 2.0Â V/0.4Â ms, while another two patients reverted to HBP due to LBBP failure (Figure 1).
All PICM patients were followed up for 27.78 ± 9.69 months. There was no significant difference in gender, age, comorbidity, or ECG characteristics among those patients who underwent CSP, BiVP, and those without an upgrade (Table 1).
TABLE 1
| Patients with CSP (n = 37) | Patients with BiVP (n = 11) | Patients without an upgrade (n = 25) | p-value | |
|---|---|---|---|---|
| Male | 17 (45.83) | 4 (36.36) | 11 (44.00) | 0.850 |
| Age | 65.69 ± 14.85 | 59.86 ± 10.79 | 69.56 ± 15.83 | 0.360 |
| Diabetes | 10 (27.08) | 2 (18.18) | 10 (40.00) | 0.346 |
| Hypertension | 24 (64.58) | 5 (45.45) | 17 (68.00) | 0.412 |
| Atrial fibrillation | 15 (41.67) | 3 (27.27) | 11 (44.00) | 0.621 |
| Coronary heart disease | 12 (31.25) | 3 (27.27) | 8 (32.00) | 0.959 |
| QRS duration (ms) | 177.08 ± 34.35 | 181.71 ± 45.54 | 170.81 ± 31.29 | 0.375 |
| LVEDD (mm) | 57.50 ± 4.85 | 60.14 ± 6.18 | 55.67 ± 7.89 | 0.301 |
| LAD (mm) | 43.81 ± 7.39 | 43.57 ± 5.03 | 41.96 ± 7.02 | 0.501 |
| LVEF (%) | 33.15 ± 5.25 | 37.00 ± 3.96 | 35.15 ± 5.04 | 0.059 |
| Mitral regurgitation | 2.35 ± 0.43 | 2.28 ± 0.39 | 2.28 ± 0.39 | 0.853 |
| Tricuspid regurgitation | 1.53 ± 0.64 | 1.71 ± 0.49 | 1.70 ± 0.49 | 0.554 |
| NYHA class | 3.04 ± 0.54 | 3.27 ± 0.47 | 3.24 ± 0.60 | 0.234 |
| NYHA II, n (%) | 4 (10.81) | 0 (0) | 0 (0) | |
| NYHA III, n (%) | 28 (75.68) | 8 (72.73) | 16 (64.00) | |
| NYHA IV, n (%) | 5 (13.51) | 3 (27.27) | 9 (36.00) | |
| Follow-up year (year) | 2.53 (1.54–3.30) | 2.21 (1.55–3.11) | 2.08 (1.69–3.05) | 0.101 |
| ACEI/ARB/ARNI (n, %) | 32 (87.50) | 10 (90.91) | 21 (84.00) | 0.900 |
| β blockers (n, %) | 33 (89.58) | 10 (90.91) | 19 (92 .00) | 0.239 |
| Diuretics (n, %) | 33 (89.58) | 11 (100) | 23 (92.00) | 0.858 |
| Digoxin (n, %) | 16 (43.85) | 6 (54.55) | 11 (44.00) | 0.801 |
Baseline characteristics of participants.
ACEI, angiotensin-converting enzyme inhibitor; ARB, angiotensin II receptor blocker; ARNI, angiotensin receptor-neprilysin inhibitor; LAD, left atrial diameter; LVEDD, left ventricular end-diastolic; LVEF, left ventricular ejection fraction.
Procedural outcomes
Paced QRS duration was slightly shorter in HBP (102.08 ± 10.04 ms) and LBBP (113.95 ± 9.28 ms) than in BiVP (147.33 ± 12.67 ms). The pacing threshold was a little higher in HBP (1.33 ± 0.32V@0.4 ms) and BiVP (1.81 ± 0.60) than in LBBP (1.01 ± 0.43V@0.4 ms).
The pacing threshold remained stable during follow-up except for a significant increase in the pacing threshold (3.0V@1.0Â ms) in one patient with HBP and BiVP. There was no infection, thrombosis, perforation, acute left heart failure, sudden death, or lead dislodgement after the upgrade. Procedural characteristics, including the complications, are shown in detail in Table 2.
TABLE 2
| HBP (n = 24) | LBBP (n = 13) | BiVP (n = 11) | p-value | |
|---|---|---|---|---|
| Baseline QRS duration (ms) | 179.21 ± 24.35 | 170.32 ± 13.34 | 182.00 ± 13.88 | 0.981 |
| Paced QRS duration (ms) | 102.08 ± 10.04 | 113.95 ± 9.28 | 147.33 ± 12.67 | 0.003 |
| Threshold during procedure (V) | 1.33 ± 0.32 | 1.01 ± 0.43 | 1.81 ± 0.60 | 0.702 |
| Threshold after follow-up(V) | 1.42 ± 0.52 | 0.90 ± 0.69 | 1.89 ± 0.63 | 0.464 |
| Threshold increase ≥1 V | 1 (2.70) | 0 | 1 (4.00) | 1.000 |
| Ventricular pacing (%) | 92.61 ± 2.98 | 93.81 ± 2.21 | 95.73 ± 2.31 | 0.661 |
| Procedural complications | 0 | 0 | 0 | |
| Lead dislodgement | 0 | 0 | 0 | |
| Infection | 0 | 0 | 0 | |
| Perforation | 0 | 0 | 0 |
Characteristics of patients based on HBP, LBBP, and BiVP upgrades.
HBP, His bundle pacing; LBBP, left bundle branch pacing; BiVP, biventricular pacing.
Clinical outcomes after follow-up
Three patients (3/25, 12.00%) died of heart failure among those who did not undergo an upgrade, and no cardiac death occurred in patients whose received the upgrade. Four patients with CSP were re-hospitalized, and one patient died of kidney failure 2 years after the upgrade. The Kaplan–Meir curve of all-cause mortality is shown in Figure 2.
FIGURE 2
The response in CSP was similar to that in BiVP (95.83% vs 81.82%, p = 0.154). Complete remodeling was more common in CSP than in BiVP patients (66.67% vs 27.27%, p = 0.040). The median time to complete reverse remodeling was 6.21 ± 3.57 months. NYHA class improved ≥1 class in CSP was similar to that in BiVP (p = 0.368), as shown in Figure 3. NYHA class improvement was not found in four patients with NYHA II and three with NYHA III. However, LVEF improvement was noticeable in seven patients (31.00% ± 3.37% vs 45.75% ± 9.74%, p = 0.037).
FIGURE 3
Echocardiographic outcomes after follow-up
It is fascinating to note that patients who experienced a decrease in the ejection fraction at baseline and received upgrades demonstrated significant improvement compared to the non-upgraded group (33.15% ± 5.25% vs 44.46% ± 6.39%, p < 0.001). Furthermore, there was a noticeable improvement in LVEF in the CSP group (32.15% ± 3.22% vs 44.95% ± 3.99%, p < 0.001) and the BiVP group (33.90% ± 3.09% vs 40.83% ± 2.99%, p < 0.001). The upgrade group also experienced a decrease in LVEDD (57.50 ± 4.85 vs 54.08 ± 4.80 mm, p < 0.05). Notably, upgraded patients generally showed improvement in tricuspid regurgitation (1.15 ± 0.46 vs 1.57 ± 0.60, p = 0.018). Additionally, significant improvements in QRS duration and NYHA class were observed in the upgraded group during follow-up compared to the baseline.
The changes in QRS duration were more evident in CSP than in BiVP (56.65 ± 11.71 vs 34.67 ± 13.32, p < 0.001) (Figure 4A). Similarly, the changes in LVEF (12.8 ± 3.66 vs 6.93 ± 3.04, p < 0.001) and LVEDD (5.80 ± 1.71 vs 3.16 ± 1.35, p < 0.001) were greater in CSP than in BiVP (Figures 4B,C). There was no statistically significant change in LVEF (11.62% ± 3.73% vs 10.55% ± 3.01%, p = 0.570) and LVEDD (6.19 ± 8.34 vs 8.70 ± 6.45 mm, p = 0.549) between HBP and LBBP. Regurgitation deterioration was found in one patient after HBP.
FIGURE 4
Discussion
In this single-center, retrospective study, we discovered that the echocardiographic response and complete reverse remodeling of the left ventricle were significantly higher in patients who underwent CRT with a CSP upgrade than those with a BiVP upgrade. Additionally, we observed similar clinical improvements between patients who received an upgrade to HBP and those who underwent an LBBP upgrade in individuals with PICM.
Different options for cardiac resynchronization in patients with PICM
Previous studies have shown that the BiVP upgrade had positive outcomes for patients with PICM. Witte et al. (2006) found that the BiVP upgrade helped reverse left ventricular dilatation and dysfunction and reduce mitral regurgitation. In a prospective cohort study, improvements in left ventricular ejection fraction (LVEF) (33.3% ± 5.2% to 47.6% ± 9.3%, p < 0.001) and NYHA grade were observed after the BiVP upgrade (Schwerg et al., 2015). Consistent with these findings, our present study also demonstrated significantly improved LVEF (33.90% ± 3.09% vs 40.83% ± 2.99%, p < 0.001) and NYHA class. The longer-paced QRS duration after RVP and the more obvious QRS duration shortening after the BiVP upgrade might be associated with a more favorable CRT response (Hsing et al., 2011). Nevertheless, a substantial portion of individuals undergoing BiVP might not attain any clinical or echocardiographic advantages, and a few might even deteriorate (European Heart Rhythm et al., 2012).
Previous research had demonstrated notable enhancements in cardiac performance following CSP. CSP was effective in electrical resynchronization, narrowed QRS complex, and improved LVEF in patients with PICM (Vijayaraman et al., 2019; Gardas et al., 2022). However, there was a lack of direct comparative studies between BiVP and CSP upgrades. In the present study, we demonstrated a much more significant reduction in QRS duration with CSP compared to BiVP. It was observed for the first time that the improvements in LVEF (ΔLVEF) and LVEDD (ΔLVEDD) were significantly higher in CSP than in BiVP, and the improvements in LVEF and LVEDD were similar between LBBP and HBP.
The present study also demonstrated a similar risk in tricuspid regurgitation with LBBP and BiVP, which was consistent with the findings of Li et al. (2022).
When addressing heart failure caused by the pacing modality, physiological pacing was the preferred option for restoring normal cardiac function in patients with PICM. Clinical trials had shown the remarkable effectiveness of physiological pacing in improving cardiac function over both short- and long-term periods when compared to traditional right ventricular pacing (RVP) (Kronborg et al., 2014; Huang et al., 2017). A recent study indicated that the incidence of PICM in HBP was significantly lower than that in RVP (2% vs 22%, p = 0.04) (Vijayaraman et al., 2018c), suggesting that HBP might be the first-line recommendation for patients at high risk of PICM.
Feasibility and safety of an upgrade in patients with PICM
BiVP procedures account for nearly a quarter of all CRT procedures. While BiVP might reduce the risk of death or heart failure by 33%, the upgrade procedure might also be associated with more complications (Valls Bertault et al., 2004; Poole et al., 2010; Linde et al., 2018). Cheung et al. (2017) examined the outcomes of CRT upgrade procedures compared to de novo CRT procedures. The findings revealed that upgrade procedures were linked to higher mortality rates, increased incidents of cardiac perforation, and a greater need for lead revision (Cheung et al., 2017). However, a meta-analysis discovered that the average complication rates for patients undergoing biventricular upgrade were 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection during a mean follow-up period of 24 months (Kaza et al., 2023). In addition, the meta-analysis reported that 3.3% of patients with biventricular upgrades and 1.8% of patients with CSP upgrades experienced complications related to lead placement. A two-center, observational, retrospective study found that the pacing threshold was 1.62 ± 1.0 V after 5 years of follow-up in HBP (Vijayaraman et al., 2018c). Guo et al. (2020) showed that the LBBP had satisfactory and stable lead parameters at 12 months. Similarly, our study showed a stable pacing threshold in patients with CSP after nearly 2 years of follow-up.
Typically, lower and more consistent pacing thresholds and higher R-wave amplitudes were observed with LBBP instead of HBP (Chen et al., 2019). This indicates that LBBP may offer a promising alternative for providing physiological pacing with improved stability in pacing thresholds (Wu et al., 2019). Our study also revealed a lower pacing threshold (p = 0.018) in LBBP than in HBP. To comprehensively assess the safety and feasibility of CSP and BiVP upgrades, randomized clinical trials with long-term follow-up would be essential.
Padala et al. (2020) reported a successful delivery of LBBP in 89% of patients. Ye et al. (2021) showed that the LBBP upgrade succeeded in 95% of patients with PICM. Our study also demonstrated a similar success ratio of the CSP upgrade (95.83%). The high success rate was attributed to the adoption of both HBP and LBBP in this study, as well as the operators’ experience.
Clinical performance of CSP in patients with PICM
In the treatment of patients with PICM, CSP plays a vital role. Huang et al. revealed that in patients with clinically symptomatic heart failure and LVEF <50%, HBP upgrade was feasible in 88.9% of cases, leading to significant improvement in left ventricular function and remodeling (Shan et al., 2018). For patients with infra-nodal atrioventricular block, LBBP emerged as a feasible option for pacing beyond the block site, serving as a reasonable alternative to cardiac resynchronization pacing via a coronary sinus lead. Furthermore, Qian et al. (2021) showed that 69.2% of LBBP patients with heart failure after right ventricular pacing experienced an absolute increase in LVEF of over 5%.
Gardas et al. (2022) found that the LVEF response was higher in HBP than in BiVP (92.3% vs 81.2%, p < 0.05). In our study, we observed that the echo response in CSP was similar to BiVP (95.83% vs 81.82%, p = 0.154). However, complete left ventricular reverse remodeling was more common in CSP than in BiVP (66.67% vs 27.27%, p = 0.040). The lack of complete cardiac reverse remodeling in PICM patients can be attributed to the existence of multiple myocardial lesions and an increase in permanent myocardial scar formation. Guan et al. (2022) demonstrated that a history of heart failure was associated with outcomes following CSP. These findings strongly suggest that CSP upgrades should be performed before irreversible heart failure develops.
Limitations
This study was an observational, single-center retrospective study. BiVP or CSP was chosen in this observational study based on patients’ preferences. Therefore, the upgrade strategy was not randomized, and the results should be interpreted with caution. Prospective, randomized trials with an extended follow-up period are crucial to compare BiVP and CSP and validate the observed outcomes identified in this study.
Conclusion
Both CSP and BiVP upgrades improved cardiac performance in PICM. The improvement in cardiac performance was more significant in CSP than in BiVP. HBP and LBBP had similar improvements in left ventricular performance, while LBBP would be an optimal choice for a lower pacing threshold compared with HBP.
Statements
Data availability statement
The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.
Ethics statement
The studies involving humans were approved by the Ethics Committee of the First Affiliated Hospital of Dalian Medical University. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants’ legal guardians/next of kin in accordance with the national legislation and institutional requirements.
Author contributions
MP-P: formal analysis, writing–original draft, conceptualization, and data curation. CY: formal analysis, writing–original draft, methodology, and software. YY-h: conceptualization, methodology, and writing–original draft. LG-c: methodology and writing–original draft. MC-m: writing–original draft and formal analysis. FQ: writing–original draft and software. GL-j: validation and writing–review and editing. XY-l: validation, writing–review and editing, and supervision. DY-x: supervision, validation, writing–review and editing, conceptualization, data curation, funding acquisition, and methodology.
Funding
The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This research was supported by the Scientific and Technological Innovation Foundation of Dalian City (2020JJ26SN055).
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fphys.2024.1355696/full#supplementary-material
References
1
AbdinA.AktaaS.VukadinovicD.ArbeloE.BurriH.GliksonM.et al (2022). Outcomes of conduction system pacing compared to right ventricular pacing as a primary strategy for treating bradyarrhythmia: systematic review and meta-analysis. Clin. Res. Cardiol.111, 1198–1209. 10.1007/s00392-021-01927-7
2
BednarekA.KiełbasaG.MoskalP.OstrowskaA.BednarskiA.SondejT.et al (2023). Left bundle branch area pacing prevents pacing induced cardiomyopathy in long-term observation. Pacing Clin. Electrophysiol.46, 629–638. 10.1111/pace.14707
3
ChenS.YinY.LanX.LiuZ.LingZ.et al (2013). Paced QRS duration as a predictor for clinical heart failure events during right ventricular apical pacing in patients with idiopathic complete atrioventricular block: results from an observational cohort study (PREDICT-HF). Eur. J. Heart Fail15, 352–359. 10.1093/eurjhf/hfs199
4
ChenX.WuS.SuL.SuY.HuangW. (2019). The characteristics of the electrocardiogram and the intracardiac electrogram in left bundle branch pacing. J. Cardiovasc Electrophysiol.30, 1096–1101. 10.1111/jce.13956
5
CheungJ. W.IpJ. E.MarkowitzS. M.LiuC. F.ThomasG.FeldmanD. N.et al (2017). Trends and outcomes of cardiac resynchronization therapy upgrade procedures: a comparative analysis using a United States National Database 2003-2013. Heart rhythm.14, 1043–1050. 10.1016/j.hrthm.2017.02.0172017.02.017
6
European Heart RhythmA.European Society ofC.HeartR. S.AuricchioA.BergerR. D.BeshaiJ. F.et al (2012). 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Heart rhythm.9, 1524–1576. 10.1016/j.hrthm.2012.07.0252012.07.025
7
GardasR.GolbaK. S.SoralT.BiernatJ.KuleszaP.SajdokM.et al (2022). The effects of his bundle pacing compared to classic resynchronization therapy in patients with pacing-induced cardiomyopathy. J. Clin. Med.11, 5723. 10.3390/jcm11195723
8
GierulaJ.CubbonR. M.JamilH. A.ByromR.BaxterP. D.PavittS.et al (2013). Cardiac resynchronization therapy in pacemaker-dependent patients with left ventricular dysfunction. Europace15, 1609–1614. 10.1093/europace/eut148
9
GuanX. M.LiD. N.ZhaoF. L.ZhaoY. N.YangY. H.DaiB. L.et al (2022). Short QRS duration after his-purkinje conduction system pacing predicts left ventricular complete reverse remodeling in patients with true left bundle branch block and heart failure. Front. Cardiovasc Med.9, 824194. 10.3389/fcvm.2022.824194
10
GuoJ.LiL.MengF.SuM.HuangX.ChenS.et al (2020). Short-term and intermediate-term performance and safety of left bundle branch pacing. J. Cardiovasc Electrophysiol.31 (6), 1472–1481. 10.1111/jce.14463
11
HerwegB.Welter-FrostA.VijayaramanP. (2021). The evolution of cardiac resynchronization therapy and an introduction to conduction system pacing: a conceptual review. Europace23, 496–510. 10.1093/europace/euaa264
12
HsingJ. M.SelzmanK. A.LeclercqC.PiresL. A.McLaughlinM. G.McRaeS. E.et al (2011). Paced left ventricular QRS width and ECG parameters predict outcomes after cardiac resynchronization therapy: PROSPECT-ECG substudy. Circ. Arrhythm. Electrophysiol.4, 851–857. 10.1161/CIRCEP.111.962605
13
HuangW.SuL.WuS.XuL.XiaoF.ZhouX.et al (2017). Benefits of permanent his bundle pacing combined with atrioventricular node ablation in atrial fibrillation patients with heart failure with both preserved and reduced left ventricular ejection fraction. J. Am. Heart Assoc.6, e005309. 10.1161/JAHA.116.005309
14
KazaN.HtunV.MiyazawaA.SimaderF.PorterB.HowardJ. P.et al (2023). Upgrading right ventricular pacemakers to biventricular pacing or conduction system pacing: a systematic review and meta-analysis. Europace25 (3), 1077–1086. 10.1093/europace/euac188
15
KhurshidS.Obeng-GyimahE.SuppleG. E.SchallerR.LinD.OwensA. T.et al (2018). Reversal of pacing-induced cardiomyopathy following cardiac resynchronization therapy. JACC Clin. Electrophysiol.4, 168–177. 10.1016/j.jacep.2017.10.0022017.10.002
16
KiehlE. L.MakkiT.KumarR.GumberD.KwonD. H.RickardJ. W.et al (2016). Incidence and predictors of right ventricular pacing-induced cardiomyopathy in patients with complete atrioventricular block and preserved left ventricular systolic function. Heart rhythm.13, 2272–2278. 10.1016/j.hrthm.2016.09.0272016.09.027
17
KronborgM. B.MortensenP. T.PoulsenS. H.GerdesJ. C.JensenH. K.NielsenJ. C. (2014). His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study. Europace16, 1189–1196. 10.1093/europace/euu011
18
LiX.ZhuH.FanX.WangQ.WangZ.LiH.et al (2022). Tricuspid regurgitation outcomes in left bundle branch area pacing and comparison with right ventricular septal pacing. Heart rhythm.19 (7), 1202–1203. 10.1016/j.hrthm.2022.03.005
19
LindeC. M.NormandC.BogaleN.AuricchioA.SterlinskiM.MarinskisG.et al (2018). Upgrades from a previous device compared to de novo cardiac resynchronization therapy in the European Society of Cardiology CRT Survey II. Eur. J. Heart Fail20, 1457–1468. 10.1002/ejhf.1235
20
LuW.LinJ.DaiY.ChenK.ZhangS. (2022). The therapeutic effects of upgrade to cardiac resynchronization therapy in pacing-induced cardiomyopathy or chronic right ventricular pacing patients: a meta-analysis. Heart Fail Rev.27, 507–516. 10.1007/s10741-021-10091-z
21
PadalaS. K.MasterV. M.TerricabrasM.ChiocchiniA.GargA.KronJ.et al (2020). Initial experience, safety, and feasibility of left bundle branch area pacing: a multicenter prospective study. JACC Clin. Electrophysiol.6, 1773–1782. 10.1016/j.jacep.2020.07.0042020.07.004
22
PooleJ. E.GlevaM. J.MelaT.ChungM. K.UslanD. Z.BorgeR.et al (2010). Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation122, 1553–1561. 10.1161/CIRCULATIONAHA.110.976076
23
QianZ.WangY.HouX.QiuY.WuH.ZhouW.et al (2021). Efficacy of upgrading to left bundle branch pacing in patients with heart failure after right ventricular pacing. Pacing Clin. Electrophysiol.44, 472–480. 10.1111/pace.14147
24
SchwergM.DregerH.PollerW. C.DustB.MelzerC. (2015). Efficacy of optimal medical therapy and cardiac resynchronization therapy upgrade in patients with pacemaker-induced cardiomyopathy. J. Interv. Card. Electrophysiol.44, 289–296. 10.1007/s10840-015-0059-4
25
ShanP.SuL.ZhouX.WuS.XuL.XiaoF.et al (2018). Beneficial effects of upgrading to His bundle pacing in chronically paced patients with left ventricular ejection fraction <50. Heart rhythm.15, 405–412. 10.1016/j.hrthm.2017.10.0312017.10.031
26
SharmaP. S.VijayaramanP.EllenbogenK. A. (2020). Permanent His bundle pacing: shaping the future of physiological ventricular pacing. Nat. Rev. Cardiol.17, 22–36. 10.1038/s41569-019-0224-z
27
SundaramS.VijayaramanP. (2020). Left bundle branch pacing. Herzschrittmacherther Elektrophysiol31, 124–134. 10.1007/s00399-020-00694-8
28
TopsL. F.SchalijM. J.BaxJ. J. (2009). The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy. J. Am. Coll. Cardiol.54, 764–776. 10.1016/j.jacc.2009.06.006
29
UdoE. O.van HemelN. M.ZuithoffN. P.DoevendansP. A.MoonsK. G. (2015). Risk of heart failure- and cardiac death gradually increases with more right ventricular pacing. Int. J. Cardiol.185, 95–100. 10.1016/j.ijcard.2015.03.0532015.03.053
30
Valls BertaultV.FatemiM.GilardM.PennecP. Y.EtienneY.BlancJ. J. (2004). Assessment of upgrading to biventricular pacing in patients with right ventricular pacing and congestive heart failure after atrioventricular junctional ablation for chronic atrial fibrillation. Europace6, 438–443. 10.1016/j.eupc.2004.04.004
31
VijayaramanP.ChungM. K.DandamudiG.UpadhyayG. A.KrishnanK.CrossleyG.et al (2018b). His bundle pacing. J. Am. Coll. Cardiol.72, 927–947. 10.1016/j.jacc.2018.06.017
32
VijayaramanP.DandamudiG.ZanonF.SharmaP. S.TungR.HuangW.et al (2018a). Permanent his bundle pacing: recommendations from a multicenter his bundle pacing collaborative working group for standardization of definitions, implant measurements, and follow-up. Heart rhythm.15, 460–468. 10.1016/j.hrthm.2017.10.0392017.10.039
33
VijayaramanP.HerwegB.DandamudiG.MittalS.BhattA. G.MarcantoniL.et al (2019). Outcomes of His-bundle pacing upgrade after long-term right ventricular pacing and/or pacing-induced cardiomyopathy: insights into disease progression. Heart rhythm.16, 1554–1561. 10.1016/j.hrthm.2019.03.0262019.03.026
34
VijayaramanP.NaperkowskiA.SubzposhF. A.AbdelrahmanM.SharmaP. S.OrenJ. W.et al (2018c). Permanent His-bundle pacing: long-term lead performance and clinical outcomes. Heart rhythm.15, 696–702. 10.1016/j.hrthm.2017.12.0222017.12.022
35
WitteK. K.PipesR. R.NanthakumarK.ParkerJ. D. (2006). Biventricular pacemaker upgrade in previously paced heart failure patients--improvements in ventricular dyssynchrony. J. Card. Fail12, 199–204. 10.1016/j.cardfail.2005.12.003
36
WuS.SuL.WangS.VijayaramanP.EllenbogenK. A.HuangW. (2019). Peri-left bundle branch pacing in a patient with right ventricular pacing-induced cardiomyopathy and atrioventricular infra-Hisian block. Europace21, 1038. 10.1093/europace/euz031
37
YangY. H.WangK. X.MaP. P.ZhangR. F.WaleedK. B.YinX.et al (2021). His-purkinje system pacing upgrade improve the heart performances in patients suffering from pacing-induced cardiomyopathy with or without permanent atrial fibrillation. Int. J. Cardiol.335, 47–51. 10.1016/j.ijcard.2021.04.0122021.04.012
38
YeY.WuS.SuL.ShengX.ZhangJ.WangB.et al (2021). Feasibility and outcomes of upgrading to left bundle branch pacing in patients with pacing-induced cardiomyopathy and infranodal atrioventricular block. Front. Cardiovasc Med.8, 674452. 10.3389/fcvm.2021.674452
Summary
Keywords
pacemaker-induced cardiomyopathy, biventricular pacing, conduction system pacing, heart failure, cardiac resynchronization therapy
Citation
Pei-pei M, Ying C, Yi-heng Y, Guo-cao L, Cheng-ming M, Qing F, Lian-jun G, Yun-long X and Ying-xue D (2024) Conduction system pacing upgrade versus biventricular pacing on pacemaker-induced cardiomyopathy: a retrospective observational study. Front. Physiol. 15:1355696. doi: 10.3389/fphys.2024.1355696
Received
14 December 2023
Accepted
02 July 2024
Published
23 July 2024
Volume
15 - 2024
Edited by
Richard Gary Trohman, Rush University, United States
Reviewed by
Richard Ang, University College London, United Kingdom
Venkatesh Ravi, Saint Francis Hospital, United States
Updates
Copyright
© 2024 Pei-pei, Ying, Yi-heng, Guo-cao, Cheng-ming, Qing, Lian-jun, Yun-long and Ying-xue.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Dong Ying-xue, dong_yingxue@126.com
†These authors have contributed equally to this work and share first authorship
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.