Correction: Neural network based active control of base isolated structure considering isolator nonlinearity

Nour Elhouda GhanemiNour Elhouda Ghanemi1Mahdi Abdeddaim
Mahdi Abdeddaim1*Abdelhafid OunisAbdelhafid Ounis1Michela BasiliMichela Basili2
  • 1LARGHYDE Laboratory, Department of Civil Engineering and Hydraulics, Faculty of Architecture, Urbanism, Civil Engineering and Hydraulics, Biskra University, Biskra, Algeria
  • 2Department of Engineering and Sciences, Universitas Mercatorum, Rome, Italy

A Correction on
Neural network based active control of base isolated structure considering isolator nonlinearity

by Ghanemi NE, Abdeddaim M, Ounis A and Basili M (2025). Front. Built Environ. 11:1630131. doi: 10.3389/fbuil.2025.1630131

Equation (10) in Section 2 - Mathematical model, was erroneously given as:

d=00001, H=10001

The correct equation is:

d=00001, H=10000

Equation (13) in Section 2 - Mathematical model, was erroneously given as:

B=M1dE00

The correct equation is:

B=M1HM1dr000

The published article stated:

[ut=futxg¨tT is the input vector collecting the ATMD force and the seismic acceleration.]

A correction has been made to the section Section 2 - Mathematical model:

“[ut=fNLtfutx¨gtT is the input vector collecting the nonlinear component of the restoring force, the force ATMD force and the seismic acceleration.]”

The original article has been updated.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Keywords: hybrid control, artificial intelligence, active tuned mass damper, base isolator, artificial neural network, linear quadratic regulator, signal time delay, white noise

Citation: Ghanemi NE, Abdeddaim M, Ounis A and Basili M (2025) Correction: Neural network based active control of base isolated structure considering isolator nonlinearity. Front. Built Environ. 11:1755156. doi: 10.3389/fbuil.2025.1755156

Received: 26 November 2025; Accepted: 08 December 2025;
Published: 18 December 2025.

Edited and reviewed by:

Songye Zhu, Hong Kong Polytechnic University, Hong Kong SAR, China

Copyright © 2025 Ghanemi, Abdeddaim, Ounis and Basili. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Mahdi Abdeddaim, bS5hYmRlZGRhaW1AdW5pdi1iaXNrcmEuZHo=

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.