Abstract
Background: The retina has gained increasing attention in non-ophthalmological research in recent years. The pattern electroretinogram (PERG), a method to evaluate retinal ganglion cell function, has been used to identify objective correlates of the essentially subjective state of depression. A reduction in the PERG contrast gain was demonstrated in patients with depression compared to healthy controls with normalization after remission. PERG responses are not only modulated by stimulus contrast, but also by check size and stimulation frequency. Therefore, the rationale was to evaluate potentially more feasible procedures for PERG recordings in daily diagnostics in psychiatry.
Methods: Twenty-four participants (12 patients with major depression (MDD) and 12 age- and sex-matched healthy controls) were examined in this pilot study. We investigated PERG amplitudes for two steady-state pattern reversal frequencies (12.5/18.75 rps) and four sizes of a checkerboard stimulus (0.8°, 1.6°, 3.2°, and 16°) to optimize the PERG recordings in MDD patients.
Results: Smaller PERG amplitudes in MDD patients were observed for all parameters, whereby the extent of the reduction appeared to be stimulus-specific. The most pronounced decline in the PERG of MDD patients was observed at the higher stimulation frequency and the finest pattern, whilst responses for the largest check size were less affected. Following the PERG ratio protocol for early glaucoma, where similar stimulus dependent modulations have been reported, we calculated PERG ratios (0.8°/16°) for all participants. At the higher frequency (18.75 rps), significantly reduced ratios were observed in MDD patients.
Conclusion: The “normalization” of the PERG responses—via building a ratio—appears to be a very promising approach with regard to the development of an objective biomarker of the depressive state, facilitating inter-individual assessments of PERG recordings in patients with psychiatric disorders.
Introduction
As an ontogenetic part of the brain, the retina exhibits high levels of many neurotransmitters of the central nervous system, including dopamine (). Since the retina represents a more accessible structure than the brain itself for related measurements, it recently gained increasing attention in other, non-ophthalmological research fields, such as neurology or psychiatry ().
Indeed, previous studies indicate alterations in visual processing in diseases which are associated with a disturbance in the central dopaminergic homeostasis. These include Parkinson's disease (–), schizophrenia (, ) and major depressive disorder (MDD) (–).
Bubl et al. () initially reported higher contrast detection thresholds in patients suffering from MDD. In further research, they took advantage of a more objective electrophysiological approach from ophthalmology, the pattern electroretinogram (PERG), to demonstrate objective correlates of the essentially subjective state of depression ().
The electroretinogram (ERG) uses corneal electrodes to measure the electrical activity of the retina in response to visual stimulation (). The PERG is mostly generated by the retinal ganglion cells () which are stimulated by local contrast changes in black/white reversing pattern stimuli, like checkerboards (, ). The PERG allows both, an assessment of the macular function and a direct measurement of the retinal ganglion cell integrity (). Therefore, it is—so far—primarily applied in ophthalmology for detecting early glaucomatous dysfunction (–).
In recent years, PERG has become increasingly important in psychiatric research as a possibility to map the integrity of the cerebral dopaminergic system indirectly via retinal ganglion cell function with minimal invasiveness (, –).
Bubl et al. (), for instance, observed a remarkable reduction in the PERG contrast gain (corresponding to the increase in amplitude with ascending stimulus contrast) of about 50% in patients with MDD compared to healthy controls, with a significant negative correlation of contrast gain with depression severity. Moreover, with remission of the depressive symptoms, a normalization of the reduced retinal signals was observed (). Therefore, it was postulated that the PERG could be a meaningful measurement tool for psychiatric disorders with the contrast gain as a state marker for depression (). Table 1 lists preliminary and present investigations focusing on the contrast sensitivity and the PERG-based contrast gain in MDD patients.
Table 1
| References | N (Patients/HC) | Age (years) mean (SD) | Measurement parameters (e.g., pattern size, reversal rate, contrast level) | Results (Patients/HC) |
|---|---|---|---|---|
| 1. Bubl et al. () | 28 MDD 21 HC | 31.8 (9.5) 33.1 (10) | Gabor patches: Size: 2 cpd Contrasts: 1, 3, 10, 20, 30, 40, 50% | Elevated contrast discrimination threshold in MDD |
| 2. Bubl et al. () [see technical note in Bubl et al. ()] | 40 MDD (20 medicated, 20 without medication) 40 HC | 43.2 (6.3) 44.6 (4.5) 41.8 (4.5) 43.3 (6.3) | PERG Check size: 0.51° Reversal rate: 12.5 rps Contrasts: 3.2, 7.3, 16.2, 36, 80% | Reduced PERG contrast gain in MDD (~50% reduction in MDD) |
| 3. Bubl et al. () | 14 MDD (10 remitted, 4 not remitted) 40 HC | 40.3 (12.8) 48.8 (9.8) 43.3 (12.7) | PERG Check size: 0.51° Reversal rate: 12.5 rps Contrasts: 3.2, 7.3, 16.2, 36, 80% | Normalization of reduced PERG-based contrast gain in MDD with remission |
| 4. Fam et al. () | 20 MDD 20 HC | 44.5 (9.8) 43.7 (9.7) | (1) PERG Check size: 0.8° Reversal rate: 12 rps Contrasts: 7, 21, 42, 56, 68% (2) ffERG: flashes 0.01/3.0 cd·s/m2) (3) Contrast sensitivity (FrACT) | Normal signals in MDD for (1) PERG contrast gain and (2) ffERG; (3) Reduced contrast sensitivity in MDD which were correlated with BDI-symptoms |
Previous studies on contrast sensitivity and/or PERG responses in patients with major depression.
BDI, beck depression inventory; cpd, cycles per degree; ffERG, full-field electroretinogram; HC, healthy controls; MDD, major depressive disorder; N, number; PERG, pattern electroretinogram; rps, reversals per second; SD, standard deviation.
The International Society for Clinical Electrophysiology of Vision (ISCEV) published the current PERG standards in 2012 with recommendations for measurement parameters, calibrations and settings of PERG recordings (). Various parameters have to be considered when recording the PERG signal.
For the standard PERG, a symmetrical black/white reversing checkerboard pattern with a constant mean luminance should be presented at a standard (15°) or large field size (≈ 30°). A check size of 0.8° (±0.2°), a reversal rate of approximately 16 rps (8 Hz) ±20% (for steady state stimulation) and a high stimulus contrast (> 80%) is recommended in the current guidelines (). As the PERG amplitude increases almost linearly with increasing stimulus contrast (), the PERG contrast gain can be calculated from a linear regression line (PERG contrast transfer function) as described by Bubl et al. (). The slope of this regression line is modulated by the stimulus frequency as well as by the check sizes presented. Higher frequencies lead to a steeper slope of the PERG contrast transfer function, whereas the use of larger patterns (≈ 4°) seems to counteract this effect ().
Aims of the Study
The recommended standard recording parameters of the ISCEV () for clinical PERG assessment have been adapted for ophthalmologic patients. However, it has not yet been investigated whether they are equally suitable for PERG recordings in psychiatric patients.
The aim of the current study was (1) to replicate the findings of reduced PERG responses in patients with depression (, ) in an independent sample and (2) to improve the PERG protocols for this patient group with a specific focus on check size and stimulus frequency.
Check Size
It is known that the PERG amplitudes attenuate with poor visual acuity (). Proper refraction is thus mandatory for PERG recordings, but difficult to implement in non-ophthalmological settings. This effect can be bypassed by using very coarse checkerboard patterns for the stimulation, which are clearly above the visual acuity threshold. In the present study, we investigated the PERG in response to a whole set of black/white reversal checkerboards with the following check sizes: 0.8°, 1.6°, 3.2°, and 16°.
Frequency
In previous studies about PERG effects in patients with depression, a stimulation frequency of 12.5 rps was applied. Higher reversal frequencies have been reported to be capable to increase the sensitivity for detecting ophthalmological diseases like glaucoma (, ). In the present study, we compared PERG amplitudes for two steady-state frequencies for pattern reversals (12.5 and 18.75 rps) to assess whether they can be applied equivalently.
Materials and Methods
Participants
The study was approved by the ethics committee of the University Medical Center Freiburg (Approval ID: 93/04) and was conducted in accordance with the Declaration of Helsinki. All participants gave their written informed consent. Patients were recruited at the Department of Psychiatry and Psychotherapy, University of Freiburg. The diagnosis of a major depressive episode was established by an experienced specialist in psychiatry according to DSM-5 criteria. A depressive episode in the context of bipolar disorder, the presence of psychotic symptoms, and comorbid alcohol abuse were defined as exclusion criteria. Initially, 17 patients with a diagnosis of major depressive disorder (MDD) were recruited. PERG measurement was performed within the first few weeks after starting antidepressant medication, without clinical response. The intake of neuroleptics, methylphenidate, or the antidepressant bupropion were defined as exclusion criteria.
In addition, 17 healthy controls without current or a history of psychiatric or neurological diseases were recruited. They had to score within the normal range of the Beck Depression Inventory [BDI; ()] and the Hamilton Depression Rating Scale [HDRS; ()]. The matching procedure controlled for effects of sex and age.
Exclusion criteria for both groups were defined as an age > 65 years, the presence of neurological or ophthalmological diseases or an uncorrectable low visual acuity (< 0.8).
The following questionnaires were collected from both patients and control participants: the Beck Depression Inventory [BDI; ()] to assess the severity of depressive symptoms and the Wender-Utah Rating Scale [WURS-k; ()] for ADHD symptoms in childhood. In addition, the Hamilton Depression Rating Scale [HDRS; ()] was applied as third-party assessment questionnaire.
Data Acquisition
Before examination, visual acuity of each participant was assessed monocularly with the Freiburg Visual Acuity and Contrast Test [FrACT; ()] and, if necessary, corrected with refraction. A minimum of 0.8 decimal visual acuity was required for each eye.
DTL (Dawson, Trick, and Litzkow)-like electrodes (), placed at the lower limbus of each eye were used for PERG recordings. Gold-cup electrodes positioned at each ipsilateral eye-canthus served as reference, an ear-clip as ground.
The EP2000 system was used for stimulation and initial data collection (https://michaelbach.de/sci/stim/ep2000/index.html; retrieval date 15.10.2021). Pattern stimuli were presented at an observer distance of 57 cm on a CRT monitor with 75 Hz frame rate in 800 x 600 pixel resolution, covering a field size of 32° × 27°. Symmetrical black/white reversal checkerboards with a mean luminance of 45 cd/m2 and a Michelson contrast of 80% served as pattern stimuli. Four different check sizes (0.8°, 1.6°, 3.2°, 16°) were presented using two different reversal frequencies (12.5 and 18.75 rps) in the steady state range. Every check size was presented for a duration of 10 sweeps with a constant sweep length for both frequencies (960 ms), starting with the lower reversal rate, followed by the higher one. Blocks for the different pattern sizes were shown in ascending manner (stepwise increasing check size: 0.8°, 1.6°, 3.4°, 16°). This sequence was repeated in 10 equal cycles, with a short break in between. Responses exceeding a threshold of 120 μV were automatically rejected as artifacts. A minimum of 100 artifact free sweeps were recorded per condition and submitted to stimulus-synchronized averaging.
Data Analysis
First off-line data processing was performed in Igor Pro 7 (Wave Metrics) with the “EP2000” module. To eliminate mains hum artifacts, averaged response traces were digitally low pass filtered (40 Hz). A Fourier analysis was performed after any linear trend (e.g., due to baseline drifts) had been removed (). PERG amplitudes were extracted from the Fourier spectra at the respective stimulation frequencies (12.5 and 18.75 Hz) and noise-corrected [as described in ()]. The average magnitude from the direct adjacent frequencies served as noise estimate (). Additionally, phases were extracted from the Fourier transformation.
Statistical Analysis
Statistical analysis was carried out in “R” () with RStudio () using the “tidyverse” package () for data handling. For the 8 stimulus conditions (4 check sizes and 2 frequencies) PERG amplitudes from both eyes were averaged for every participant separately. Psychometric data comparisons and initial testing for differences between the groups or stimulation parameters were established using Wilcoxon rank sum tests [“rstatix” package ()]. Response times (in ms) were calculated from the extracted phase values (). The fully crossed factorial design was analyzed with a mixed analysis of variance (ANOVA) for repeated measures [“afex” package ()]. The factors group, check size and stimulation frequency, as well as their interactions, were evaluated for their impact on PERG amplitudes or response times. The factors check size and frequency were considered as repeated measures factors for each subject. Post-hoc analysis was limited to group comparisons [“emmeans” package ()] with equal variance assumed. Hedge corrected () Cohen's d was calculated as effect size estimation for unpaired samples [“rstatix” package ()]. Significance levels were determined by applying the Bonferroni-Holm procedure for a familywise α of 0.05 ().
Results
Demographic and Psychometric Data
Of the originally measured 17 patients, five had to be excluded. The reasons for exclusion were intolerance of the electrodes, the intake of neuroleptic medication, regular somatic medication, subsequently diagnosed psychiatric comorbidity and substance abuse. Finally, 12 patients between 19 and 51 years of age could be included in the final analysis. Four patients suffered from a first severe depressive episode, while 8 patients had a recurrent severe depressive episode. Of the 17 control participants measured, 12 were matched by sex and age to the included patients and considered in the final analysis. The psychometric data of the patient and the control groups are presented in Table 2.
Table 2
| Characteristic | Controls, N = 12 | Patients, N = 12 | p-valuea | |
|---|---|---|---|---|
| Sex | Male | 5/12 (42%) | 5/12 (42%) | |
| Female | 7/12 (58%) | 7/12 (58%) | ||
| Age | Mean (SD) | 29 (8) | 26 (9) | 0.087 |
| Range | 20–51 | 19–51 | ||
| Medication | Medicated | 0/12 (0%) | 11/12 (92%) | |
| Unmedicated | 12/12 (100%) | 1/12 (8.3%) | ||
| WURS-k | Mean (SD) | 11 (6) | 23 (13) | 0.003 |
| Median (IQR) | 8 (7, 15) | 18 (16, 27) | ||
| BDI | Mean (SD) | 3 (3) | 25 (8) | <0.001 |
| Median (IQR) | 3 (1, 5) | 25 (18, 32) | ||
| (Missing) | 0 | 1 | ||
| HDRS | Mean (SD) | 1 (1) | 22 (4) | <0.001 |
| Median (IQR) | 1 (0, 1) | 22 (20, 26) |
Demographic and psychometric data.
Statistical test: Wilcoxon rank-sum test. BDI, Beck Depression Inventory; HDRS, Hamilton Depression Rating Scale; IQR, interquartile range; N, number; SD, standard deviation; WURS-k, Wender-Utah Rating Scale; y, years.
Pattern Electroretinogram (PERG)
Group Averaged PERG Responses
In both groups, measures of one eye of each of two participants had to be excluded due to electrode displacement during the experiment. Except for these cases, the responses of both eyes were averaged before further analysis.
Figure 1 illustrates the mean PERG amplitudes for patients and controls for all stimulus conditions.
Figure 1
The overall average of the PERG response of patients suffering from MDD was significantly lower compared to the control group (p = 0.017, unpaired, one-sided Wilcoxon test assuming lower PERG for MDD; data pooled across stimulus parameters), with a similar signal to noise ratio for both groups (p = 0.242, unpaired, two-sided Wilcoxon test, data averaged across stimulus parameters).
Although the average PERG amplitude in response to the higher frequency (18.75 rps) was significantly lower (p < 0.001; paired, one-sided Wilcoxon test assuming lower PERG at 18.75 rps; data averaged across groups and check sizes), the signal-to-noise ratio was comparable for both frequencies (p = 0.121; paired, two-sided Wilcoxon test, data pooled across groups and check sizes). Further visual inspection suggests largest amplitudes in response to the smallest check size with a slight attenuation toward coarser patterns.
The overall average of PERG response time was significantly reduced in patients with MDD compared to healthy controls (p < 0.001, unpaired, two-sided Wilcoxon test, data pooled across stimulus parameters).
Mixed ANOVA Results
With a mixed ANOVA, PERG amplitudes were evaluated for (between) group differences and influences from check size or stimulation frequency, both considered as subject-wise repeated measures (within). Possible interaction effects were included.
The ANOVA revealed a significant effect for the between factor group [F(1, 22) = 6.53, p = 0.018] and the within factors check size [F(1.52, 33.41) = 55.42, p < 0.001] and stimulation frequency [F(1, 22) = 53.02, p < 0.001], as well as a significant interaction between the two stimulus parameters [F(1.79, 39.38) = 19.24, p < 0.001] on the PERG amplitudes. Interactions between stimulus conditions and the factor group were not observed.
A separate ANOVA calculated for response times showed significant effects for the factors group [F(1, 22) = 14.70, p < 0.001], frequency [F(1, 22) = 88.14, p < 0.001] and size [F(1.48, 32.51) = 1313.83, p < 0.001].
Post-hoc Analysis for Group Differences
A subsequent post-hoc comparison of the two groups indicated significantly reduced PERG amplitudes in the MDD group for almost all stimulus parameters (Table 3), considering the uncorrected results. After correcting significance levels for multiple comparisons according to the Bonferroni-Holm procedure, group differences remained significant only for the finest pattern (0.8°). At 18.75 rps, the decline of PERG in MDD (Table 3) apparently scales with the check size of the stimulus.
Table 3
| Check Size [°] | Frequency [rps] | Controls mean (SD) | Patients mean (SD) | Differences of estimated marginal means (SE) | P-value (significance level Holm adjusted) | Hedge corrected Cohen's d |
|---|---|---|---|---|---|---|
| 0.8 | 12.5 | 2.9 (0.5) | 2.3 (0.7) | 0.621 (0.21) | 0.007 (*) | 0.98 |
| 1.6 | 12.5 | 2.5 (0.5) | 2 (0.6) | 0.549 (0.21) | 0.015 (ns) | 1.00 |
| 3.2 | 12.5 | 2.3 (0.5) | 1.8 (0.5) | 0.553 (0.21) | 0.014 (ns) | 1.13 |
| 16 | 12.5 | 2.3 (0.5) | 1.8 (0.5) | 0.490 (0.21) | 0.028 (ns) | 0.95 |
| 0.8 | 18.75 | 2.5 (0.5) | 1.9 (0.7) | 0.630 (0.21) | 0.006 (*) | 1.04 |
| 1.6 | 18.75 | 2.2 (0.4) | 1.7 (0.5) | 0.514 (0.21) | 0.022 (ns) | 1.03 |
| 3.2 | 18.75 | 2.1 (0.4) | 1.6 (0.5) | 0.431 (0.21) | 0.051 (ns) | 0.95 |
| 16 | 18.75 | 2.2 (0.5) | 1.8 (0.5) | 0.331 (0.21) | 0.127 (ns) | 0.67 |
Results from the post-hoc analysis for PERG amplitudes (in μV).
Pairwise group comparisons (contrast: controls–patients) for all stimulus conditions with the corresponding differences in the estimated marginal means (SE included), the arithmetic mean and standard deviation (SD) for patients and controls as well as the effect size estimation (Cohen's d Hedge corrected) for group differences. Significance levels were adjusted according to Bonferroni-Holm procedure.
significant; ns, not significant.
In an additional post-hoc analysis, we detected shorter response times for patients with MDD compared to healthy controls for all stimulus parameter combinations (Table 4).
Table 4
| Check size [°] | Frequency [rps] | Controls mean (SD) | Patients mean (SD) | Differences of estimated marginal means (SE) | P-value (significance level Holm adjusted) | Hedge corrected Cohen's d |
|---|---|---|---|---|---|---|
| 0.8 | 12.5 | 55.2 (2.9) | 51.9 (3) | 3.37 (0.96) | 0.002 (*) | 1.09 |
| 1.6 | 12.5 | 51.7 (2.6) | 48.3 (2.8) | 3.42 (0.96) | 0.001 (*) | 1.22 |
| 3.2 | 12.5 | 48.9 (2.2) | 45.3 (2.4) | 3.58 (0.96) | 0.001 (*) | 1.53 |
| 16 | 12.5 | 44.7 (2.1) | 41.5 (2.4) | 3.22 (0.96) | 0.002 (*) | 1.36 |
| 0.8 | 18.75 | 56.4 (1.8) | 53.2 (2.5) | 3.19 (0.96) | 0.003 (*) | 1.41 |
| 1.6 | 18.75 | 53.4 (2) | 49.6 (2.3) | 3.79 (0.96) | 0.001 (*) | 1.69 |
| 3.2 | 18.75 | 50.4 (2.1) | 46.5 (2) | 3.87 (0.96) | <0.0001 (*) | 1.84 |
| 16 | 18.75 | 46.5 (2.1) | 43 (1.8) | 3.52 (0.96) | 0.001 (*) | 1.72 |
Results from the post-hoc analysis for calculated response times (in ms).
Pairwise group comparisons (contrast: controls–patients) for all stimulus conditions with the corresponding differences in the estimated marginal means (SE included), the arithmetic mean and standard deviation (SD) for patients and controls as well as the effect size estimation (Cohen's d Hedge corrected) for group differences. Significance levels were adjusted according to Bonferroni-Holm procedure.
significant; ns, not significant.
Cohen's d Effect Size Estimation for Stimulus Parameter Combinations
Figure 2 shows that, at a stimulation frequency of 18.75 rps, the PERG response difference between patients and healthy controls is gradually smaller with increasing check size. The most prominent decay in patients' PERG amplitudes was observed with the finest pattern (0.8°) (25%, d = 1.04), while the PERG amplitudes at the coarsest checkerboard (16°) seemed to be least affected (15%, d = 0.67). Interestingly, this PERG response pattern is reminiscent of the conditions observed in early glaucoma (, , ).
Figure 2
PERG Check Size Ratio
Based on the “PERG ratio protocol” in early glaucoma (, , ), check size ratios for the PERG amplitudes were established for both groups and frequencies according to formula (1).
With regard to the application of PERG response as an objective biomarker, the calculation of PERG ratios for every subject has the advantage of minimizing inter-individual variability by amplitude normalization. Figure 3 depicts the normalized PERG amplitudes for the patient and the control group.
Figure 3
A second mixed ANOVA with the between factor group, the within-factor stimulation frequency and the PERG ratio as dependent variable revealed a significant influence of stimulus frequency on the PERG ratio [F(1, 22) = 29.23, p < 0.001], no overall-group differences [F(1, 22) = 3.33, p = 0.082], but a significant interaction effect between group and stimulus frequency [F(1, 22) = 6.96, p = 0.015].
Post-hoc evaluation exhibited that the PERG ratios in the MDD group, in response to a stimulation frequency of 18.75 rps, were significantly reduced (p = 0.008, d = 1.07), whereas with the lower reversal rate (12.5 rps), PERG ratios did not differ between groups (p = 0.674, d = 0.18).
Discussion
The aims of the present study were (1) the replication of the PERG amplitude effect in patients with MDD and (2) the evaluation of different stimulus conditions to further improve PERG recording procedures for this patient group. Four check sizes (0.8°, 1.6°, 3.2°, and 16°) were compared to analyze if PERG signals in MDD, in response to coarser patterns, are affected to the same extent as to smaller check sizes used in previous studies. The application of coarser patterns would be beneficial by eliminating influences due to refraction errors. In addition, two frequencies (12.5 and 18.75 rps) for checkerboard reversals were investigated in order to test if PERG responses were similarly affected at higher stimulation frequencies.
Group Comparisons for the Different Parameter Combinations
Overall, we discerned smaller PERG amplitudes in patients with MDD compared to matched healthy control participants, which replicates earlier findings with an independent sample of patients and controls (
This effect was not only present for the lower (12.5 rps), as previously reported (
The higher rate for checkerboard reversals (18.75 rps) is additionally beneficial by fine-tuning group differences between MDD and control subjects through check size dependent modulations, which allow for a normalization of PERG responses via the calculation of check size ratios, similar to those used for the detection of early glaucoma (
Besides, our observations are not in line with the results of Fam et al. (
Since the PERG amplitude reduction in patients with MDD was only significant with the smallest check size (0.8°), we cannot recommend a recording paradigm which uses exclusively larger check sizes (1.6°, 3.2°, or 16°) in the context of psychiatric disorders, which would render the correction of refractive anomalies unnecessary.
Considering the dopamine-dependent regulation of the receptive field sizes in the retina (
Moreover, shortened response times were observed in patients with MDD for all stimulus conditions. As described in transient stimulations (
PERG Ratio
While it would have been useful to find strong effects of depression with the very large check sizes, which would have obviated refraction, one can turn the relative constancy of these amplitudes into our favor by using them for individual normalization. Inspired by the PERG ratio protocol in early glaucoma (
Methodological Issues and Limitations
The present study provides promising perspectives for the optimization of PERG recording procedures in psychiatric settings. However, some limitations have to be mentioned.
Due to the small number of patients, the results of the current study must be considered preliminary. Follow-up studies with larger samples sizes could yield further information about the adaptation of stimulation frequency and check size for PERG recordings in psychiatric patients. It should be noted, however, that the PERG ratio is feasible to minimize inter-individual differences.
At the time of measurement, patients had already been taking antidepressant medication for a few days or weeks. In a previous study by Bubl et al. (
Summary
In summary, in this methodological pilot study we could reproduce earlier findings of reduced PERG amplitudes in patients with depression as a potentially objective biomarker signal of the essentially subjective state of depression. In addition, we were able to methodologically improve the recording procedure by demonstrating the suitability of a higher stimulation frequency for recordings along with the introduction of an interpersonal normalization approach for the PERG signals, which further enhances the sensitivity of the method.
Funding
Part of the study was funded by the DFG (HE 3504/11-1 | TE 280/24-1). The article processing charge was funded by the Baden-Wuerttemberg Ministry of Science, Research and Art and the University of Freiburg in the funding programme Open Access Publishing.
Publisher's Note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Statements
Data availability statement
The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author/s.
Ethics statement
The studies involving human participants were reviewed and approved by the Ethics Committee of the University Medical Center Freiburg (Approval ID: 93/04). The patients/participants provided their written informed consent to participate in this study.
Author contributions
KN and EF wrote the paper. EF, KN, CS, and SM performed the data and statistical analysis. LTvE, KN, DEb, MB, and EF organized the study and created the study design. KN, DEb, and DEn recruited the patients and established the diagnosis. MB and SH supported the methodological and technical realization for the collection of the electrophysiological data. CS and EF performed the measurements. LTvE, KD, SM, DEb, DEn, KR, EB, MB, JK, and SH revised the manuscript critically focusing on clinical and statistical aspects. All authors were critically involved in the theoretical discussion, composition of the manuscript, and read and approved the final version of the manuscript.
Conflict of interest
LTvE Advisory boards, lectures, or travel grants within the last three years: Roche, Eli Lilly, Janssen-Cilag, Novartis, Shire, UCB, GSK, Servier, Janssen, and Cyberonics. KD member of the “Steering Committee Neurosciences,” Janssen Pharmaceuticals, Inc. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
1.
NguyenCTOHuiFCharngJVelaedanSvan KoeverdenAKLimJKHet al. Retinal biomarkers provide ‘insight’ into cortical pharmacology and disease. Pharmacol Therapeut. (2017) 175:151–77. 10.1016/j.pharmthera.2017.02.009
2.
AlmonteMTCapellànPYapTECordeiroMF. Retinal correlates of psychiatric disorders. Therapeut Adv Chronic Dis. (2020) 11:1–21. 10.1177/2040622320905215
3.
Tebartz van ElstLGreenleeMWFoleyJMLückingCH. Contrast detection, discrimination and adaptation in patients with Parkinson's disease and multiple system atrophy. Brain J Neurol. (1997) 120(Pt 12):2219–28.
4.
BrandiesRYehudaS. The possible role of retinal dopaminergic system in visual performance. Neurosci Biobehav Rev. (2008) 32:611–56. 10.1016/j.neubiorev.2007.09.004
5.
ArmstrongRA. Visual symptoms in Parkinson's disease. Parkinsons Dis. (2011) 2011:e908306. 10.4061/2011/908306
6.
SilversteinSKeaneBPBlakeRGierschAGreenMKériS. Vision in schizophrenia: why it matters. Front Psychol. (2015) 6:41. 10.3389/fpsyg.2015.00041
7.
SilversteinSMFradkinSIDemminDL. Schizophrenia and the retina: towards a 2020 perspective. Schizophrenia Res. (2020) 219:84–94. 10.1016/j.schres.2019.09.016
8.
BublETebartz van ElstLGondanMEbertDGreenleeMW. Vision in depressive disorder. World J Biol Psychiatry. (2009) 10 (4 Pt 2):377–84. 10.1080/15622970701513756
9.
BublEKernEEbertDBachMTebartz van ElstL. Seeing gray when feeling blue? Depression can be measured in the eye of the diseased. Biol Psychiatry. (2010) 68:205–8. 10.1016/j.biopsych.2010.02.009
10.
BublEEbertDKernETebartz van ElstLBachM. Effect of antidepressive therapy on retinal contrast processing in depressive disorder. Brit J Psychiatry. (2012) 201:151–8. 10.1192/bjp.bp.111.100560
11.
RobsonAGNilssonJLiSJalaliSFultonABTormeneAPet al. ISCEV guide to visual electrodiagnostic procedures. Document Ophthalmol. (2018) 136:1–26. 10.1007/s10633-017-9621-y
12.
LuoXFrishmanLJ. Retinal pathway origins of the pattern electroretinogram (PERG). Investig Ophthalmol Visual Sci. (2011) 52:8571–84. 10.1167/iovs.11-8376
13.
BachMHoffmannMB. The origin of the pattern electroretinogram. In: HeckenlivelyJRArdenGB editors. Principles Practice of Clinical Electrophysiology of Vision. 2nd ed. Cambridge, MA: MIT Press (2006), p. 185–96.
14.
BachMBrigellMGHawlinaMHolderGEJohnsonMAMcCullochDLet al. ISCEV standard for clinical pattern electroretinography (PERG): 2012 update. Document Ophthalmol. (2012) 124:1–13. 10.1007/s10633-012-9353-y
15.
HolderGE. Pattern electroretinography (PERG) and an integrated approach to visual pathway diagnosis. Prog Retinal Eye Res. (2001) 20:531–61. 10.1016/S1350-9462(00)00030-6
16.
BachM. Electrophysiological approaches for early detection of glaucoma. Eur J Ophthalmol Suppl. (2001) 11 (Suppl 2):S41–9. 10.1177/112067210101102s05
17.
BachMHoffmannMB. Update on the pattern electroretinogram in glaucoma. Optomet Vision Sci. (2008) 85:386–95. 10.1097/OPX.0b013e318177ebf3
18.
BachMRamharter-SereinigA. Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG ratio protocols. Document Ophthalmol. (2013) 127:227–38. 10.1007/s10633-013-9412-z
19.
LangheinrichTTebartz van ElstLLagrèzeWABachMLückingCHGreenleeMW. Visual contrast response functions in Parkinson's disease: evidence from electroretinograms, visually evoked potentials and psychophysics. Clin Neurophysiol. (2000) 111:66–74. 10.1016/s1388-2457(99)00223-0
20.
LavoieJIllianoPSotnikovaTDGainetdinovRRBeaulieuJ-MHébertM. The electroretinogram as a biomarker of central dopamine and serotonin: potential relevance to psychiatric disorders. Biological Psychiatry. (2014) 75:479–86. 10.1016/j.biopsych.2012.11.024
21.
LavoieJMaziadeMHébertM. The brain through the retina: the flash electroretinogram as a tool to investigate psychiatric disorders. Prog Neuropsychopharmacol Biol Psychiatry. (2014) 48:129–34. 10.1016/j.pnpbp.2013.09.020
22.
SchwitzerTSchwanRBublELalanneLAngioi-DuprezKLaprevoteV. Looking into the brain through the retinal ganglion cells in psychiatric disorders: a review of evidences. Prog Neuropsychopharmacol Biol Psychiatry. (2017) 76:155–62. 10.1016/j.pnpbp.2017.03.008
23.
BublEKernEEbertDRiedelATebartz van ElstLBachM. Retinal dysfunction of contrast processing in major depression also apparent in cortical activity. Eur Arch Psychiatry Clin Neurosci. (2015) 265:343–50. 10.1007/s00406-014-0573-x
24.
FamJRushAJHaalandBBarbierSLuuC. Visual contrast sensitivity in major depressive disorder. J Psychosom Res. (2013) 75:83–6. 10.1016/j.jpsychores.2013.03.008
25.
Ben-ShlomoGBachMOfriR. Temporal and spatial frequencies interact in the contrast transfer function of the pattern electroretinogram. Vision Res. (2007) 47:1992–9. 10.1016/j.visres.2007.04.009
26.
BachMMathieuM. Different effect of dioptric defocus vs. light scatter on the pattern electroretinogram (PERG). Document Ophthalmol. (2004) 108:99–106. 10.1023/b:doop.0000018415.00285.56
27.
TrickGL. Retinal potentials in patients with primary open-angle glaucoma: physiological evidence for temporal frequency tuning deficits. Investig Ophthalmol Visual Sci. (1985) 26:1750–58.
28.
HissPFahlG. [Changes in the pattern electroretinogram in glaucoma and ocular hypertension are dependent on stimulus frequency]. Fortschritte Der Ophthalmologie Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft. (1991) 88:562–65.
29.
BeckATWardCHMendelsonMMockJErbaughJ. An inventory for measuring depression. Arch Gen Psychiatry. (1961) 4:561–71.
30.
HamiltonM. A rating scale for depression. J Neurol Neurosurg Psychiatry. (1960) 23:56–62. 10.1136/jnnp.23.1.56
31.
Retz-JungingerPRetzWBlocherDWeijersH-GTrottEWenderPHet al. Wender Utah Rating Scale (WURS-k) Die deutsche Kurzform zur retrospektiven Erfassung des hyperkinetischen Syndroms bei Erwachsenen. Der Nervenarzt. (2002) 73:830–38. 10.1007/s00115-001-1215-x
32.
BachM. The Freiburg visual acuity test–automatic measurement of visual acuity. Optometry Vision Sci. (1996) 73:49–53. 10.1097/00006324-199601000-00008
33.
DawsonWWTrickGLLitzkowCA. Improved electrode for electroretinography. Invest Ophthalmol Vis Sci. (1979) 18:988–91.
34.
BachMMeigenT. Do's and don'ts in Fourier analysis of steady-state potentials. Doc Ophthalmol. (1999) 99:69–82. 10.1023/A:1002648202420
35.
MeigenTBachM. On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol. (1999) 98:207–32. 10.1023/A:1002097208337
36.
R Core Team. R: A Language and Environment for Statistical Computing. Vienna: R Foundation for Statistical Computing (2020). Available online at: https://www.R-project.org/
37.
RStudioTeam. RStudio: Integrated Development Environment for R. Boston, MA: RStudio, PBC (2020). Available online at: http://www.rstudio.com/
38.
WickhamHAverickMBryanJChangWMcGowanLFrançoisRet al. Welcome to the Tidyverse. J Open Source Softw. (2019) 4:1686. 10.21105/joss.01686
39.
KassambaraA. Rstatix: Pipe-Friendly Framework for Basic Statistical Tests (2020). Available online at: https://CRAN.R-project.org/package=rstatix
40.
BodeSFNJehleTBachM. Pattern electroretinogram in glaucoma suspects: new findings from a longitudinal study. Investig Opthalmol Visual Sci. (2011) 52:4300. 10.1167/iovs.10-6381
41.
SingmannHBolkerBWestfallJAustFBen-ShacharMS. Afex: Analysis of Factorial Experiments (2020). Available online at: https://CRAN.R-project.org/package=afex
42.
LenthRV. Emmeans: Estimated Marginal Means, Aka Least-Squares Means (2020). Available online at: https://CRAN.R-project.org/package=emmeans
43.
HedgesLVOlkinI. Statistical methods for meta-analysis. In: CHAPTER 5 - Estimation of a Single Effect Size: Parametric and Nonparametric Methods. Orlando, FL: Academic Press (1985). p. 75–106. 10.1016/C2009-0-03396-0
44.
HolmS. A simple sequentially rejective multiple test procedure. Scand J Statist. (1979) 6:65–70.
45.
BachMUnsoeldASPhilippinHStaubachFMaierPWalterHSet al. Pattern ERG as an early glaucoma indicator in ocular hypertension: a long-term, prospective study. Investig Ophthalmol Visual Sci. (2006) 47:4881–7. 10.1167/iovs.05-0875
46.
PoloschekCMBachM. [Electrophysiological examination methods in glaucoma diagnostics]. Der Ophthalmologe: Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft. (2012) 109:358–63. 10.1007/s00347-012-2546-7
47.
AndersL-MHeinrichSPLagrèzeWAJoachimsenL. Little effect of 0.01% atropine eye drops as used in myopia prevention on the pattern electroretinogram. Document Ophthalmol. (2019) 138:85–95. 10.1007/s10633-019-09671-0
48.
RoySFieldGD. Dopaminergic modulation of retinal processing from starlight to sunlight. J Pharmacol Sci. (2019) 140:86–93. 10.1016/j.jphs.2019.03.006
49.
EbertDLammersC-H. Das zentrale dopaminerge System und die Depression. Der Nervenarzt. (1997) 68:545–55. 10.1007/s001150050159
50.
DunlopBWNemeroffCB. The role of dopamine in the pathophysiology of depression. Arch Gen Psychiatry. (2007) 64:327. 10.1001/archpsyc.64.3.327
51.
BachMHolderGE. Check size tuning of the pattern electroretingoram: a reappraisal. Document Ophthalmol. (1996) 92:193–202. 10.1007/BF02583290
52.
ViswanathanSFrishmanLJRobsonJG. The uniform field and pattern ERG in macaques with experimental glaucoma: removal of spiking activity. Investig Ophthalmol Visual Sci. (2000) 41:2797–810.
53.
DaniJA. Roles of dopamine signaling in nicotine addiction. Mol Psychiatry. (2003) 8:255–6. 10.1038/sj.mp.4001284
54.
BublEDörrMPhilipsenAEbertDBachMTebartz van ElstL. Retinal contrast transfer functions in adults with without ADHD. PLoS ONE. (2013) 8:e61728. 10.1371/journal.pone.0061728
55.
WernerALTebartz van ElstLEbertDFriedelEBublAClementHWet al. Normalization of increased retinal background noise after ADHD treatment: a neuronal correlate. Schizophr Res. (2019) 219:77–83. 10.1016/j.schres.2019.04.013
Summary
Keywords
pattern electroretinogram, PERG, depression, check size, dopamine
Citation
Friedel EBN, Tebartz van Elst L, Schmelz C, Ebert D, Maier S, Endres D, Runge K, Domschke K, Bubl E, Kornmeier J, Bach M, Heinrich SP and Nickel K (2021) Replication of Reduced Pattern Electroretinogram Amplitudes in Depression With Improved Recording Parameters. Front. Med. 8:732222. doi: 10.3389/fmed.2021.732222
Received
28 June 2021
Accepted
06 October 2021
Published
29 October 2021
Volume
8 - 2021
Edited by
Jason C. Park, University of Illinois at Chicago, United States
Reviewed by
Jan Kremers, University Hospital Erlangen, Germany; Shresta Patangay, University of Illinois at Chicago, United States
Updates

Check for updates
Copyright
© 2021 Friedel, Tebartz van Elst, Schmelz, Ebert, Maier, Endres, Runge, Domschke, Bubl, Kornmeier, Bach, Heinrich and Nickel.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ludger Tebartz van Elst tebartzvanelst@uniklinik-freiburg.de
†These authors share first authorship
This article was submitted to Ophthalmology, a section of the journal Frontiers in Medicine
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.