ORIGINAL RESEARCH article

Front. Med., 23 September 2024

Sec. Nuclear Medicine

Volume 11 - 2024 | https://doi.org/10.3389/fmed.2024.1462870

99mTc-FAPI-04 SPECT/CT outperforms contrast-enhanced CT in detecting metastasis in postoperative patients with colorectal cancer

  • 1. Department of Nuclear Medicine, Yangpu Hospital, School of Medicine, Tongji University, Shanghai, China

  • 2. Department of Nuclear Medicine, The First Affiliated Hospital of Naval Medical University, Shanghai, China

Abstract

Purpose:

To compare the performance of 99mTc-FAPI-04 SPECT/CT and contrast-enhanced CT (CECT) in the detection of postoperative metastasis in patients with colorectal cancer (CRC).

Methods:

The postoperative patients with CRC were consecutively recruited from January 2023 to June 2023, and the enrolled patients completed 99mTc-FAPI-04 SPECT/CT imaging and CECT examination within two weeks. Histopathological analysis and the follow-up results were used as the reference criteria. The location and number of metastatic sites and the detection accuracy between the two imaging methods were compared. The tumor-to-background ratio (TBR) of liver metastasis and lymph node metastasis in 99mTc-FAPI-04 SPECT/CT imaging were also calculated for comparison.

Results:

In total, 19 postoperative CRC patients, including 15 patients with metastasis, were included in this study. In the patient-based analysis, 99mTc-FAPI-04 SPECT/CT showed a significantly higher sensitivity for the detection of metastasis than CECT (93.3% vs. 80.0%, p = 0.038), but both techniques had the same specificity (100%, 4/4). For the lesion-based analysis, the detection rates of metastatic sites were 92.2% (47/51) and 72.5% (37/51) for 99mTc-FAPI-04 SPECT/CT and CECT, respectively, and the difference between them was statistically significant. In the diagnosis of liver metastasis and lymph node metastasis, 99mTc-FAPI-04 SPECT/CT both exceeded CECT. Additionally, the TBR in lymph node metastasis was higher than that in liver metastasis.

Conclusion:

The findings suggested that 99mTc-FAPI-04 SPECT/CT could detect metastasis more effectively than CECT, especially liver and lymph node metastases, in postoperative CRC patients.

1 Introduction

Colorectal cancer (CRC) is the third most commonly diagnosed cancer in the world and ranks second in the number of cancer-related deaths, seriously damaging public health (1). Curative surgical resection is the main method of treating CRC patients, but approximately 30–50% of postoperative patients face the risks of relapse or metastasis. Thus, new strategies are needed for early detection and corresponding intervention to improve clinical outcomes (2). Contrast-enhanced CT (CECT) is routinely used to monitor CRC recurrence and metastasis after surgery because of its widespread application and high-resolution assessment of anatomical structures (3). Nuclear medicine imaging modalities, including single-photon emission computed tomography/X-ray computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT), can efficiently provide functional and morphological information on lesions, and they also have the advantage of whole-body scan; these reasons make them suitable for detecting tumor recurrence and metastasis. The 18F-fluorodeoxyglucose (18F-FDG) PET/CT technique is used as the standard-of-care imaging for initial staging and re-staging, treatment response, follow-up, and postoperative surveillance of CRC patients (4, 5).

Fibroblast activation protein (FAP) is overexpressed in cancer-associated fibroblasts (CAFs) in more than 90% of epithelial tumors, including CRC, but its level of expression in normal organs is low (6, 7). FAP-targeted PET/CT using 68Ga or 18F-labeled FAP inhibitors (FAPIs) is a highly promising imaging tool for the diagnosis, staging, monitoring recurrence, and metastasis of various cancers (8, 9). Recent studies have suggested that 68Ga-FAPI-04 PET/CT has higher sensitivity and specificity than 18F-FDG in detecting primary tumors and metastases in patients with CRC (10–12). However, the lack of availability and high cost of PET/CT scanning facilities greatly limits routine clinical use. Generally speaking, PET imaging system using the coincidence detection of two γ-rays with an energy of 511 keV that are produced when a positron released by the positron emitter radionuclide (e.g., 18F and 68Ga) annihilates with an electron, has higher spatial resolution and sensitivity than SPECT imaging, which employs physical collimator to reject photons [e.g., 140 keV photons from the gamma-ray emitter technetium-99m (99mTc)] that are not within a small angular range (13). Although 68Ga-PET gives better image quality than 99mTc-SPECT, the latter is cheaper and more feasible. Thus, SPECT as a widely used molecular imaging technique remains a good choice for the diagnosis and treatment follow-up of tumors. Herein, we conducted a comparative study on the performance of 99mTc-labeled FAPI-04 SPECT/CT and CECT in detecting metastasis in postoperative patients with CRC.

2 Population and methods

2.1 Patient population

All patients provided written informed consent before the study. Postoperative CRC patients with suspected metastases who had not previously undergone chemotherapy or targeted therapy were enrolled from January 2023 to June 2023. For the enrolled patients, 99mTc-FAPI-04 SPECT/CT imaging and CECT examination were performed for the evaluation of tumor metastasis, which were completed within 2 weeks.

2.2 Image acquisition

The precursor HYNIC-FAPI-04 kit containing 20 μg of HYNIC-FAPI-04, 10 mg of ethylenediamine-NcN′-diacetic acid (EDDA), 20 mg of tricine and 50 μg of SnCl2 was purchased from Shanghai Nice-labeling Biotechnology Co. Ltd. 99mTc-NaTcO4 was provided by Shanghai Atom Kexing Pharmaceutical Co., Ltd., and the radiolabeling was performed according to the instruction manual (Supplementary Figure S1). Briefly, 2 mL of freshly eluted 99mTc-NaTcO4 solution (2.22 GBq) was mixed with the precursor kit, and then was heated at 100°C for 15 min to prepare 99mTc-HYNIC-FAPI-04 (abbreviated as 99mTc-FAPI-04). Before each use, the labeling rate of 99mTc-FAPI-04 was measured using a mini-scan radio-thin layer chromatography (TLC) scanner, in which silica gel paper strip and acetone was used as the stationary phase and mobile phase, respectively. Generally, 99mTc-FAPI-04 exhibits an excellent labeling rate (over 95%, Supplementary Figure S2) and a high specific activity of >650 MBq/nmol, meaning that the radiotracer can be used directly without additional purification.

For SPECT/CT examination, the patients received an intravenous injection of 740 MBq of 99mTc-FAPI-04, and then, whole-body SPECT imaging and SPECT/CT fusion images were taken using the GE Discovery (NM/CT 670) SPECT/CT system 60 min after injection. For CECT examination, the patients first underwent CT plain scanning, and then, they were injected intravenously with 80–120 mL of Iodixanol (270 mg/mL, Yangtze River Pharmaceutical Group Co., Ltd., China), followed by enhanced CT scanning at the artery phase (30 s delay) portal venous phase (65 s delay) using a Siemens SOMATOM Definition AS 64-row 128-slice 4D spiral CT scanner.

2.3 Image analysis

The 99mTc-FAPI-04 SPECT/CT images were analyzed by two experienced nuclear medicine physicians. In SPECT/CT fusion images, the sites with local radioactivity accumulation and simultaneous positive CT scan results were diagnosed as having metastatic lesions. To determine the tumor-to-background ratio (TBR), the tumor region of interest (ROI) was delineated on the largest cross-section of the lesions in the co-registered SPECT/CT images, and the system software would give the radioactive counts per unit automatically. Similarly, ROI with the same size was drawn in muscle as the background. Lastly, the TBR was calculated by comparing the radioactive counts per unit volume of metastasis sites with that in the background. For CECT, images were analyzed by two senior abdominal radiologists using the radiological criteria. Generally, lesions were suspected based on temporal criteria (recent appearance) and morphological criteria (nodules or masses without typical benign characteristics).

2.4 Statistical analysis

All statistical analyses were performed using SPSS 20.0. The measurement data were expressed as the mean ± standard deviation (SD). The differences in the rates between the two methods were compared by χ2-test (or the Fisher exact test when appropriate), and p < 0.05 was considered to be statistically significant.

3 Result

3.1 Patient characteristics

The study included 19 postoperative patients with CRC, including 15 males and 4 females (average age: 59.53 ± 13.39 years). The primary tumors included 3 ascending colon cancers, 4 transverse colon cancers, 4 descending colon cancers, and 4 rectal cancers. The median time of the postoperative course was 18.42 months (range: 1–60 months), and the mean duration of postoperative follow-up was 95.16 days (range: 45–180 days). Metastasis was confirmed by tissue biopsy or repeated postoperative pathological, clinical, and imaging follow-up results. All participants underwent 99mTc-FAPI-04 SPECT/CT imaging and CECT examination without serious adverse effect. The characteristics of the patients are summarized in Table 1.

Table 1

CharacteristicValue
No. of patients19
Sex
Male15
Female4
Age (years)
Mean ± SD59.53 ± 13.39
Primary tumor
Ascending colonic adenocarcinoma3
Transverse colonic adenocarcinoma4
Sigmoid colonic adenocarcinoma4
Rectum adenocarcinoma4
Postoperative time course (months)
Mean (range)18.42 (1, 60)
Postoperative follow-up time (days)
Mean (range)95.16 (45, 180)

Summary of the characteristics of the patients.

SD, standard deviation.

3.2 Comparative assessment of the performance of metastasis detection

In the patient-based analysis, no metastasis was detected in 4 postoperative CRC patients, as confirmed by the two imaging methods (Figure 1). Among 15 CRC patients, postoperative metastasis was detected in 14 patients and 12 patients through 99mTc-FAPI-04 SPECT/CT and CECT, respectively, suggesting that the two imaging methods were effective for detecting postoperative metastasis of CRC (Figure 2). However, 99mTc-FAPI-04 SPECT/CT had greater sensitivity than CECT (93.3% vs. 80.0%, χ2 = 4.286, p = 0.038). The different types of follow-up imaging examination of a postoperative CRC patient are shown in Figure 3; the atypical imaging features of liver metastases on CECT prevented the radiologists from making a definitive diagnosis, but the 99mTc-FAPI-04 probe was effectively taken up by the metastatic lesions, which immensely helped us evaluate the clinical disease status.

Figure 1

Figure 2

Figure 3

In total, 51 metastatic lesions were found in 15 patients, including 19 liver metastases, 20 lymph node metastases, 7 lung metastases, 1 spleen metastasis, 1 adrenal gland metastasis, and 3 bone metastases (Table 2). The results of 99mTc-FAPI-04 SPECT/CT imaging and CECT examination found 47 lesions and 37 lesions, respectively, with a significant difference between the two methods (92.16% vs. 72.55%, χ2 = 4.927, p = 0.026). Especially, regarding the detection of liver and lymph node metastases, 99mTc-FAPI-04 SPECT/CT imaging showed higher sensitivity than CECT (Table 2). SPECT imaging can be used for total-body scanning, which helps find more metastatic lesions. For example, in one postoperative CRC patient with multiple metastatic lesions, compared to CECT, the 99mTc-FAPI-04 SPECT/CT imaging technique detected additional cervical lymph node metastasis (Figure 4).

Table 2

Imaging methodThe number of lesions
Liver (19)Lymph node (20)Lung (7)Spleen (1)Adrenal gland (1)Bone (3)Total (51)
SPECT/CT1818611347
CECT1513701137
χ23.9584.127————4.927
p0.0470.042————0.026

The results of 99mTc-FAPI-04 SPECT/CT and CECT examinations for detecting metastatic lesions (n = 15).

FAPI-04, fibroblast activation protein inhibitor-04; SPECT/CT, single-photon emission computed tomography/X-ray computed tomography; CECT, contrast-enhanced CT.

Figure 4

3.3 Comparison of TBR in liver metastasis and lymph node metastasis

According to the 99mTc-FAPI-04 SPECT/CT image, the radioactive counts per unit volume of lymph node metastases were significantly higher than that of liver metastases (p = 0.017). Additionally, significantly higher TBR values were found in lymph node metastases than in liver metastases (p = 0.010) (Table 3).

Table 3

MetastasisThe number of lesionsRadioactive counts per unit volumeTBR
LesionsMuscle
Liver18911.58 ± 296.59256.11 ± 77.293.61 ± 1.16
Lymph181286.04 ± 546.35288.79 ± 77.064.48 ± 1.61
p0.0170.2130.010

A comparison of the radioactive counts per unit volume and the TBR in liver and lymph node metastases.

TBR, tumor-to-background ratio.

4 Discussion

Imaging examination plays an important role in the diagnosis, staging, re-staging, metastatic spread, and treatment monitoring of CRC (14–16). In the clinical setting, CECT is a recommended imaging modality for evaluating postoperative CRC patients with suspected tumor recurrence or distant metastasis (17). However, CECT has several limitations, such as the iodine contrast agent-induced nephropathy in patients with renal impairment, allergic reactions, and particularly, a limited scan range; due to these reasons, it has a good chance of missing some metastatic lesions (18). In contrast, nuclear medicine whole-body functional imaging modality facilitates the evaluation of tumor metabolism, proliferation, activity and parameters affecting treatment outcomes, and has unique advantages in monitoring the post-therapy recurrence and metastasis of tumor. Currently, the radionuclide-labeled FAPI is one of the most attractive novel nuclear medicine molecular probes, and the effectiveness of FAPI-based PET/CT for the diagnosis of various tumors has been evaluated as compared with 18F-FDG PET/CT. For example, in the detection of primary and metastatic lung cancer lesions, 18F-FAPI PET/CT exhibited higher sensitivity than 18F-FDG PET/CT (19); 68Ga-FAPI-04 PET/CT was superior to CECT or 18F-FDG PET/CT for detecting primary and recurrent CRC, as confirmed by several clinical studies (10–12, 20). Certainly, PET/CT plays a significant role in monitoring the postoperative status of CRC, but this imaging technique bears some drawbacks, including its high cost, relatively complex synthetic method of positron-emitting radiopharmaceuticals. Unlike PET/CT, SPECT/CT is a cheaper and readily available modality. The single-photon emitting radionuclide 99mTc can be got easily from 99Mo/99mTc generator, and clinically, 99mTc-labeled radiopharmaceuticals SPECT/CT serves as a simple, economical, convenient and widespread diagnostic procedure. For these reasons, SPECT/CT has received much attention from researchers, particularly with the application of novel molecular probes. For example, 99mTc-PSMA and 99mTc-FAPI SPECT/CT can be used as a substitute for 68Ga-PSMA and 68Ga-FAPI PET/CT to some extent in the evaluation of specific tumors, respectively (21). Thus, determining the efficacy of 99mTc-FAPI-04 SPECT/CT in the diagnosis of metastasis after radical resection of CRC and assessing its superiority over CECT are important steps.

Among the 19 CRC patients recruited in this study who underwent radical operations, tumor metastasis was found in 15 patients, and the postoperative metastasis rate reached 78.95%. Reliable assessment of the disease status was the prerequisite for making appropriate treatment plans. Among all participants, 4 postoperative CRC patients without metastasis were diagnosed as negative in 99mTc-FAPI-04 SPECT/CT imaging and CECT examination, which indicated that both techniques had high specificity in evaluating metastatic lesions, but SPECT/CT imaging displayed higher sensitivity. For the sake of accurately detecting tumor metastasis, 99mTc-FAPI-04 SPECT/CT is a better choice than CECT for the postoperative follow-up examination of CRC. Overall, the patient-based analysis showed that the 99mTc-FAPI-04 SPECT/CT imaging technique is highly valuable in detecting metastasis in postoperative CRC patients. However, a multicenter clinical trial with a larger sample size is needed to validate this conclusion.

Whole-body scanning and functional imaging techniques, which show the activity of the key molecules of tumors without relying on the anatomical changes in lesions, use 99mTc-FAPI-04 SPECT/CT with a good ability to more accurately find metastatic lesions in earlier stages. Among the 51 lesions detected in 15 postoperative CRC patients, 47 lesions showed high uptake of 99mTc-FAPI-04, mainly in the liver (18 lesions), lymph nodes (18 lesions), and lungs (6 lesions). However, no radiotracer uptake was found in a few metastatic lesions in lymph nodes (2 lesions), liver (1 lesion), and lungs (1 lesion). One reason for this false-negative result is that these metastatic lesions were too small, with a maximum diameter of <0.5 cm. In CRC tumor tissue, FAP is mainly expressed by CAFs, and the amount and activity of CAFs largely determine the expression of FAP. Therefore, tiny metastatic lesions with a small quantity of CAFs have negligible uptake of 99mTc-FAPI-04. Also, a high concentration of 99mTc-FAPI-04 was detected in the abdominal surgical scar and lung fibrosis tissue in 2 postoperative CRC patients, which occurred because fibroblasts in these tissues were activated along with the overexpression of FAP (22–24). To reduce the rate of misdiagnosis, a detailed analysis of history, clinical symptoms, and relevant physical examination is needed to interpret the 99mTc-FAPI-04 SPECT/CT results.

Although CECT is used as the first-line diagnostic tool for detecting recurrent and metastatic CRC, it has some limitations when used alone. The efficacy of CECT lies in its ability to provide the anatomical information of lesions, but the tiny lesions and the distant metastatic lesions may be missed. By comparison, SPECT/CT provides physiological information along with anatomical information, and may be a better alternative to assess the disease progression of the patients undergoing therapy. For example, 99mTc-Sestamibi SPECT/CT has been reported to have an incremental value over CECT for differentiating malignant or aggressive renal tumors from benign or indolent ones, because the former can give the pathophysiological characteristics of different types of diseases (25). According to our present study, among the 51 postoperative metastatic lesions mentioned above, only 37 lesions could be diagnosed clearly by CECT, including 15 liver metastases and 13 lymph node metastases; in both types of metastases, its diagnostic performance was inferior to that of 99mTc-FAPI-04 SPECT/CT. The remaining 13 lesions were undetectable, indeterminate, or negative. Thus, CECT missed 4 liver metastatic lesions in 3 patients, including 2 patients with 2 lesion and 1 patient with 2 lesions. In CECT images, these lesions generally had a small low-density area with weak enhancement, without the typical features of CRC liver metastases. The lesion volume, tube current, and slice thickness influenced the image quality of CECT, resulting in its low diagnostic efficacy in liver metastasis (26, 27). Our results were similar to those of another study, in which it was reported that 99mTc-FAPI SPECT/CT has greater diagnostic efficiency than CECT in detecting the distant metastasis of patients with digestive system tumors, especially in identifying liver metastases (28). Additionally, 7 cervical and mediastinal lymph node metastases, 1 spleen metastasis, and 2 bone metastases were missed by CECT, indicating that the ability of CECT to detect distant metastases in postoperative CRC patients is limited. Namely, SPECT/CT is a more sensitive and accurate tool for evaluating distant metastases than CECT.

With the development of iterative image reconstruction by incorporating compensations for collimator-detector response, attenuation and scatter, SPECT quantification in terms of standard uptake value (SUV) or kBq/cc become feasible, providing a more accurate method for monitoring tumor metabolic response. Regretfully, our SPECT/CT system did not incorporate the tools or algorithms for generating quantitative SPECT data, and we chose TBR as an alternative tool to assess the uptake of 99mTc-FAPI-04 in metastases. In this study, lymph node metastases had a higher and more stable uptake of 99mTc-FAPI-04 than liver metastases, along with a higher TBR value. By analyzing the SPECT/CT image of liver metastases, we found that liver lesions varied in size from less than 1 cm to over 8 cm, and the huge metastatic lesions had several small areas of necrotic tissues with low density, leading to the non-uniform uptake of 99mTc-FAPI-04 by the lesions. In contrast, lymph node metastases were relatively small, with a maximum diameter of ≤3 cm, homogeneous density, and uniform distribution of radiotracer. The combination of the above factors facilitated a more significant accumulation of 99mTc-FAPI-04 and a higher TBR in metastatic lymph nodes, suggesting that 99mTc-FAPI-04 SPECT/CT is a highly promising tool for the radiological follow-up of postoperative CRC at risk of lymph node metastasis.

5 Conclusion

To summarize, compared to CECT, 99mTc-FAPI-04 SPECT/CT showed higher sensitivity in detecting metastatic lesions, especially liver and lymph node metastases. These findings indicated that it may be used to assess metastases in postoperative patients with CRC in routine clinical practice.

Statements

Data availability statement

The original contributions presented in the study are included in the article/Supplementary material, further inquiries can be directed to the corresponding authors.

Ethics statement

The studies involving humans were approved by the Ethics Review Committee of Yangpu Hospital. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

DS: Conceptualization, Formal analysis, Investigation, Methodology, Validation, Writing – original draft. LM: Conceptualization, Formal analysis, Methodology, Validation, Writing – original draft. YL: Formal analysis, Investigation, Methodology, Writing – original draft. CB: Methodology, Resources, Software, Writing – original draft. GJ: Software, Visualization, Writing – original draft. TW: Conceptualization, Formal analysis, Methodology, Project administration, Supervision, Validation, Writing – review & editing. YW: Conceptualization, Formal analysis, Funding acquisition, Methodology, Project administration, Resources, Supervision, Visualization, Writing – review & editing.

Funding

The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This work was supported by the Clinical Problem-Based Research Fund of Yangpu Hospital (Se1202204) and Shanghai Pujiang Program (2022PJD014).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2024.1462870/full#supplementary-material

References

  • 1.

    SiegelRLWagleNSCercekASmithRAJemalA. Colorectal cancer statistics, 2023. CA Cancer J Clin. (2023) 73:233–54. doi: 10.3322/caac.21772

  • 2.

    GurayaSY. Pattern, stage, and time of recurrent colorectal cancer after curative surgery. Clin Colorectal Cancer. (2019) 18:e223–8. doi: 10.1016/j.clcc.2019.01.003

  • 3.

    BensonABVenookAPAl-HawaryMMArainMAChenYJCiomborKKet al. Colon cancer, version 2.2021, NCCN clinical practice guidelines in oncology. J Natl Compr Cancer Netw. (2021) 19:329–59. doi: 10.6004/jnccn.2021.0012

  • 4.

    MaffioneAMRubelloDCaroliPCollettiPMMatteucciF. Is it time to introduce PET/CT in colon cancer guidelines?Clin Nucl Med. (2020) 45:525–30. doi: 10.1097/RLU.0000000000003076

  • 5.

    ShiYWangMZhangJXiangZLiCZhangJet al. Tailoring the clinical management of colorectal cancer by 18F-FDG PET/CT. Front Oncol. (2022) 12:1062704. doi: 10.3389/fonc.2022.1062704

  • 6.

    XingFSaidouJWatabeK. Cancer associated fibroblasts (CAFs) in tumor microenvironment. Front Biosci. (2010) 15:166–79. doi: 10.2741/3613

  • 7.

    ZhangHYueXChenZLiuCWuWZhangNet al. Define cancer-associated fibroblasts (CAFs) in the tumor microenvironment: new opportunities in cancer immunotherapy and advances in clinical trials. Mol Cancer. (2023) 22:159. doi: 10.1186/s12943-023-01860-5

  • 8.

    AltmannAHaberkornUSivekeJ. The latest developments in imaging of fibroblast activation protein. J Nucl Med. (2021) 62:160–7. doi: 10.2967/jnumed.120.244806

  • 9.

    KratochwilCFlechsigPLindnerTAbderrahimLAltmannAMierWet al. 68Ga-FAPI PET/CT: tracer uptake in 28 different kinds of cancer. J Nucl Med. (2019) 60:801–5. doi: 10.2967/jnumed.119.227967

  • 10.

    LinXLiYWangSZhangYChenXWeiMet al. Diagnostic value of [68Ga] Ga-FAPI-04 in patients with colorectal cancer in comparison with [18F] F-FDG PET/CT. Front Oncol. (2023) 12:1087792. doi: 10.3389/fonc.2022.1087792

  • 11.

    ChengZWangSXuSDuBLiXLiY. FAPI PET/CT in diagnostic and treatment management of colorectal cancer: review of current research status. J Clin Med. (2023) 12:577. doi: 10.3390/jcm12020577

  • 12.

    KƶmekHCanCKaplanİGündoğanCKepenekFKaraoglanHet al. Comparison of [68Ga] Ga-DOTA-FAPI-04 PET/CT and [18F] FDG PET/CT in colorectal cancer. Eur J Nucl Med Mol Imaging. (2022) 49:3898–909. doi: 10.1007/s00259-022-05839-0

  • 13.

    RahmimAZaidiH. PET versus SPECT: strengths, limitations and challenges. Nucl Med Commun. (2008) 29:193–207. doi: 10.1097/MNM.0b013e3282f3a515

  • 14.

    Van CutsemEVerheulHMFlamenPRougierPBeets-TanRGlynne-JonesRet al. Imaging in colorectal cancer: progress and challenges for the clinicians. Cancers. (2016) 8:81. doi: 10.3390/cancers8090081

  • 15.

    CarusoDPoliciMBelliniDLaghiA. ESR essentials: imaging in colorectal cancer-practice recommendations by ESGAR. Eur Radiol. (2024) 34:5903–10. doi: 10.1007/s00330-024-10645-3

  • 16.

    van der StokEPSpaanderMCWGrunhagenDJVerhoefCKuipersEJ. Surveillance after curative treatment for colorectal cancer. Nat Rev Clin Oncol. (2017) 14:297–315. doi: 10.1038/nrclinonc.2016.199

  • 17.

    NeriEVagliPTuriniFCerriFFaggioniLAngeliSet al. Post-surgical follow-up of colorectal cancer: role of contrast-enhanced CT colonography. Abdom Imaging. (2010) 35:669–75. doi: 10.1007/s00261-009-9596-6

  • 18.

    KatzbergRWBarrettBJ. Risk of iodinated contrast material-induced nephropathy with intravenous administration1. Radiology. (2007) 243:622–8. doi: 10.1148/radiol.2433061411

  • 19.

    WeiYMaLLiPLuJRenJYanSet al. FAPI compared with FDG PET/CT for diagnosis of primary and metastatic lung cancer. Radiology. (2023) 308:e222785. doi: 10.1148/radiol.222785

  • 20.

    PangYZhaoLLuoZHaoBWuHLinQet al. Comparison of 68Ga-FAPI and 18F-FDG uptake in gastric, duodenal, and colorectal cancers. Radiology. (2021) 298:393–402. doi: 10.1148/radiol.2020203275

  • 21.

    FallahiBKhademiNKaramzade-ZiaratiNFard-EsfahaniAEmami-ArdekaniAFarzanefarSet al. 99mTc-PSMA SPECT/CT versus 68Ga-PSMA PET/CT in the evaluation of metastatic prostate cancer. Clin Nucl Medi. (2021) 46:e68–74. doi: 10.1097/RLU.0000000000003410

  • 22.

    FitzgeraldAAWeinerLM. The role of fibroblast activation protein in health and malignancy. Cancer Metast Rev. (2020) 39:783–803. doi: 10.1007/s10555-020-09909-3

  • 23.

    RƶhrichMLeitzDGlattingFMWefersAKWeinheimerOFlechsigPet al. Fibroblast activation protein-specific PET/CT imaging in fibrotic interstitial lung diseases and lung cancer: a translational exploratory study. J Nucl Med. (2022) 63:127–33. doi: 10.2967/jnumed.121.261925

  • 24.

    LiuYZhangQZhangYWangJWuYYangGet al. 99mTc-labeled FAPI SPECT imaging in idiopathic pulmonary fibrosis: preliminary results. Pharmaceuticals. (2023) 16:1434. doi: 10.3390/ph16101434

  • 25.

    PariharASMhlangaJRonstromCSchmidtLRFigenshauRSDehdashtiFet al. Diagnostic accuracy of 99mTc-Sestamibi SPECT/CT for characterization of solid renal masses. J Nucl Med. (2023) 64:90–5. doi: 10.2967/jnumed.122.264329

  • 26.

    SchulzAViktilEGodtJCJohansenCKDormagenJBHoltedahlJEet al. Diagnostic performance of CT, MRI and PET/CT in patients with suspected colorectal liver metastases: the superiority of MRI. Acta Radiol. (2016) 57:1040–8. doi: 10.1177/0284185115617349

  • 27.

    SivesgaardKLarsenLPSĆørensenMKramerSSchlanderSAmanaviciusNet al. Diagnostic accuracy of CECT, MRI and FDG PET/CT for detecting colorectal cancer liver metastases in patients considered eligible for hepatic resection and/or local ablation. Eur Radiol. (2018) 28:4735–47. doi: 10.1007/s00330-018-5469-0

  • 28.

    JiaXLiXJiaBYangYWangYLiuYet al. The role of 99mTc-HFAPi SPECT/CT in patients with malignancies of digestive system: first clinical experience. Eur J Nucl Med Mol Imaging. (2023) 50:1228–39. doi: 10.1007/s00259-022-06068-1

Summary

Keywords

99mTc-FAPI-04, SPECT/CT, contrast-enhanced CT, colorectal cancer, metastasis

Citation

Sun D, Ma L, Liu Y, Bao C, Jia G, Wang T and Wang Y (2024) 99mTc-FAPI-04 SPECT/CT outperforms contrast-enhanced CT in detecting metastasis in postoperative patients with colorectal cancer. Front. Med. 11:1462870. doi: 10.3389/fmed.2024.1462870

Received

10 July 2024

Accepted

03 September 2024

Published

23 September 2024

Volume

11 - 2024

Edited by

Orit Jacobson, National Institutes of Health (NIH), United States

Reviewed by

Bruna Fernandes, National Institutes of Health, United States

Gregory Ravizzini, University of Texas MD Anderson Cancer Center, United States

Updates

Copyright

*Correspondence: Tao Wang, ; Yingqiu Wang,

†These authors have contributed equally to this work

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics