Your new experience awaits. Try the new design now and help us make it even better

CASE REPORT article

Front. Med., 23 January 2026

Sec. Dermatology

Volume 13 - 2026 | https://doi.org/10.3389/fmed.2026.1686516

High-resolution 3T-MRI with microcoil enhancement for preoperative evaluation of cutaneous squamous cell carcinoma: a case report and literature review

  • Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China

Background: Cutaneous squamous cell carcinoma (cSCC) is a common non-melanoma skin cancer with potential for local invasion and metastasis. Accurate preoperative assessment is essential for optimal treatment planning.

Materials and methods: We report a case of an 83-year-old female patient who presented with a progressively enlarging scalp mass over 3 months. HR-MRI revealed a mixed-signal lesion (22 × 15 × 26 mm) in the right scalp. On T1-weighted imaging (T1WI) and T2-weighted imaging (T2WI), the lesion exhibited heterogeneous signals with an irregular, crater-like surface. Post-contrast imaging demonstrated significant heterogeneous enhancement. The tumor was located within the epidermis, dermis, and subcutaneous fat, closely adhering to the galea aponeurotica with well-defined margins. Surgical resection and histopathological examination confirmed a (exophytic type) moderately to well-differentiated cSCC (2.8 × 2.3 × 2.0 cm) infiltrating the subcutaneous tissue but without perineural invasion or deeper tissue involvement.

Results: HR-MRI provided clear visualization of tumor morphology, infiltration depth, and relationship with surrounding structures. Compared to conventional MRI, HR-MRI improved the accuracy of tumor boundary delineation, offering valuable information for preoperative planning.

Conclusion: HR-MRI plays a significant role in the evaluation of cSCC, particularly in assessing tumor infiltration depth and differentiating it from other cutaneous malignancies. Its high-resolution imaging facilitates early detection, precise surgical planning, and improved patient outcomes.

Introduction

Cutaneous squamous cell carcinoma (cSCC) is the second most common non-melanoma skin cancer (NMSC) following basal cell carcinoma(BCC) (1). The incidence of skin cancer is rising, particularly in older populations, with cSCC being a leading cause of skin cancer-related morbidity. Although surgical excision is typically effective, some cSCC cases are associated with a higher risk of recurrence, metastasis, and mortality (2). Clinically, cSCC often presents as a rapidly enlarging mass or a non-healing ulcer. Diagnosis is based on histopathology, with wide local excision being the most commonly used treatment. However, assessing the exact tumor size and depth of infiltration remains challenging and is often based on clinical judgment or dermoscopy, which can lead to suboptimal prognostic outcomes and delayed recovery (35). Magnetic resonance imaging (MRI) is a valuable tool for assessing cSCC, particularly in larger tumors, by providing detailed information on tumor invasion and its relationship to surrounding structures (6, 7). However, conventional MRI techniques can be limited in accurately delineating tumor margins, particularly in smaller or superficially invasive tumors. High-resolution 3T-MRI with Microcoil Enhancement offers improved resolution, allowing for better visualization of early invasion and microstructural changes, potentially enhancing diagnostic accuracy.

This study aims to demonstrate the clinical utility of microcoil-enhanced 3T-MRI in the evaluation of cutaneous squamous cell carcinoma (cSCC), using a pathologically confirmed case of scalp cSCC. Unlike previous studies that primarily addressed the technical feasibility of high-resolution MRI for cutaneous tumors, this case emphasizes the incremental preoperative value of microcoil-enhanced 3T-MRI over conventional MRI, particularly in the accurate delineation of tumor margins and assessment of infiltration depth, which are critical for surgical planning.

Case report

Clinical data

An 83-year-old female patient presented with a progressively enlarging scalp mass over 3 months. Initially asymptomatic, the lesion was later evaluated due to its increasing size.

Imaging assessment

A 3T-MRI scanner (VIDA, Siemens Medical Solutions, Erlangen, Germany) with a high-resolution microscopy coil was used. T2-weighted fast spin-echo (FSE) imaging was performed in the coronal plane with parameters: TR/TE 2447/100 ms, slice thickness 2 mm, field of view (FOV) 70 × 70 mm, matrix 256 × 256, and echo train length (ETL) 12. T1-weighted FSE imaging was also performed in the coronal plane with TR/TE 400/22 ms, maintaining the same slice thickness, FOV, and matrix as T2WI, with an ETL of 4. Post-contrast T1-weighted FSE imaging was performed after intravenous administration of 0.1 mmol/kg contrast agent.

HR-MRI revealed a mixed-signal lesion in the right scalp. The lesion demonstrated heterogeneous signal intensity on both T1-weighted and T2-weighted images, with intermixed hypo- to isointense components on T1WI and predominantly hyperintense areas on T2WI, likely reflecting keratinization and associated inflammatory components. The lesion exhibited a well-defined base and close adherence to the galea aponeurotica. On microcoil-enhanced HR-MRI, the lesion measured approximately 22 × 15 × 26 mm along the maximum axial and craniocaudal dimensions. Protruding from the scalp surface with an irregular, crater-like appearance. Post-contrast imaging demonstrated significant heterogeneous enhancement (Figure 1). Minor discrepancies between MRI-based measurements and histopathological dimensions may be partially attributed to differences in measurement orientation and tissue shrinkage following formalin fixation. Surgical resection was performed the following day.

Figure 1
MRI scans showing side and top views of a brain with a prominent lesion highlighted by arrows. Images A, B, D, and E show sagittal views of the lesion. Images C and F show coronal views, indicating a protruding mass.

Figure 1. 3T-MRI findings in a case of squamous cell carcinoma in an 83-year-old female. (a) Coronal T1-weighted 3T-MRI demonstrates an oval-shaped lesion with heterogeneous hypointense signals and an irregular surface contour (arrow). (b) Coronal T2-weighted 3T-MRI reveals a mixed hyperintense mass with superficial ulceration (arrow) and adjacent linear hyperintense foci, indicative of peritumoral inflammatory changes. (c) Conventional T1-weighted fat-suppressed MRI shows ill-defined lesion margins (arrow). (d) Post-contrast coronal T1-weighted MRI highlights heterogeneous enhancement (arrow), correlating with tumor angiogenesis. (e) T1-weighted fat-suppressed MRI sequence accurately delineates the involvement of the dermal-subcutaneous junction (arrow). (f) Conventional T1-weighted fat-suppressed imaging exhibits reduced soft tissue contrast resolution compared to MRI (arrow).

Histopathological findings: Histopathological examination confirmed an exophytic, moderately to well-differentiated cSCC measuring 2.8 × 2.3 × 2.0 cm, with a height of 2.0 cm (Figure 2). The tumor infiltrated the subcutaneous tissue but had negative margins, with no evidence of perineural invasion or deeper tissue involvement.

Figure 2
Histological image showing fibrous tissue with a pinkish hue, characterized by swirling collagen fibers and scattered dark purple nuclei. Scale bar indicates increments up to 200 micrometers.

Figure 2. Histological specimen (hematoxylin and eosin staining) reveals tumor cells of cutaneous squamous cell carcinoma arranged in a trabecular pattern, with abundant keratin pearls present. The tumor cells exhibit large size, abundant eosinophilic cytoplasm, and large, vacuolated nuclei with prominent nucleoli. The surrounding stromal components are distinctly evident.

Discussion

Although uncomplicated cSCC can often be cured with surgery combined with local therapy, there remains a clear clinical need for more objective and noninvasive diagnostic tools to guide clinicians in developing detailed biopsy strategies and surgical plans for lesions with atypical features or suspected subcutaneous extension (8). Commonly used modalities—such as high-frequency ultrasound (HFUS) (9), optical coherence tomography (OCT) (10), dermoscopy (11), and CT (12)—provide useful structural information but have notable limitations. HFUS offers excellent axial resolution but limited penetration, reducing its ability to assess deeper margins. OCT provides near-histologic visualization but is restricted to a depth of 1–2 mm. Dermoscopy is confined to surface morphology, and CT lacks sufficient soft-tissue contrast for thin cutaneous lesions (912). In contrast, HR-MRI combines high spatial resolution with adequate tissue penetration, enabling three-dimensional assessment of tumor thickness, peritumoral inflammation, and involvement of deeper structures. Thus, HR-MRI provides more comprehensive preoperative information than HFUS or OCT, especially for lesions in which deeper invasion must be excluded.

High-resolution MRI is a noninvasive technique capable of quasi-histologic, in vivo visualization of the skin (13). By employing small surface coils (<100 mm) in combination with a 3T or higher MRI system, HR-MRI achieves substantially higher spatial resolution than conventional surface coils (13). This capability allows for visualization of tissue structures not identifiable with standard imaging techniques. Its primary clinical value lies in delineating deep and peripheral tumor margins, providing dermatologic surgeons—particularly those performing Mohs micrographic surgery—with a reliable preoperative roadmap (14). HR-MRI has also been successfully applied to imaging superficial anatomical structures such as the orbit (15), parotid gland (16), and small joints of the hands and feet (17, 18).

Although high-resolution or microcoil-based MRI has been previously reported in the evaluation of various cutaneous tumors, its direct contribution to preoperative decision-making in cutaneous squamous cell carcinoma (cSCC) remains under-reported. This case illustrates how microcoil-enhanced high-resolution MRI can provide clinically actionable information beyond conventional MRI, particularly for surgical planning. In this case of scalp cutaneous squamous cell carcinoma (cSCC), 3T-MRI with Microcoil Enhancement demonstrated significant value by providing detailed visualization of tumor morphology, infiltration depth, and its relationship with surrounding tissues, thereby improving the accuracy of preoperative assessment. The tumor displayed typical exophytic features of cSCC, including an ovoid or cauliflower-like appearance with ulceration and a crater-like surface. These findings are consistent with previous reports, where MRI has proven effective in identifying characteristic tumor features and assessing their extent (19).

A major strength of this examination was the superior performance of microcoil-enhanced HR-MRI compared with conventional MRI. Three critical advantages were observed. First, the use of a microcoil markedly increased signal-to-noise ratio (SNR) by reducing coil–tissue distance, enabling thinner slices and minimizing partial-volume effects. This enhancement allowed visualization of microstructural features—such as dermal–subcutaneous junction disruption and crater-like ulceration—that are often indistinct on routine MRI. Second, HR-MRI improved staging accuracy by differentiating tumor-confined involvement of the fat layer from deeper galeal or fascial invasion. Third, the technique facilitated preoperative planning by enabling precise delineation of tumor margins; in this case, an approximate 2-mm boundary was identified and later confirmed histologically.

The results of this case further support the potential of HR-MRI in differentiating cSCC from other cutaneous malignancies, including basal cell carcinoma (BCC), melanoma, and cutaneous lymphoma. While these findings align with existing literature, they also highlight the superior resolution and enhanced image contrast provided by HR-MRI compared with conventional MRI, especially for tumors with irregular borders or superficial invasions (Table 1).

Table 1
www.frontiersin.org

Table 1. Differential diagnosis of cutaneous squamous cell carcinoma in the head and neck region (20).

Limitations

Despite these advantages, there are limitations to this study. The case report design restricts generalizability, and the findings are based on a single patient’s data. Additionally, while 3T-MRI provided detailed information on tumor boundaries, it remains subject to limitations inherent to MRI, such as motion artifacts and reliance on high-quality imaging equipment. Further studies with larger cohorts and prospective designs are necessary to validate the broader applicability of 3T-MRI in cSCC and other skin cancers.

Conclusion

This case suggests that microcoil-enhanced 3T high-resolution MRI may offer incremental value over conventional MRI in the preoperative assessment of cutaneous squamous cell carcinoma. Although further studies with larger cohorts are required to validate these findings, HR-MRI appears to be a promising tool for improving preoperative evaluation and surgical planning in cSCC.

Data availability statement

The datasets presented in this study can be found in online repositories. The names of the repository/repositories and accession number(s) can be found in the article/supplementary material.

Ethics statement

Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

SC: Writing – original draft. SZ: Writing – review & editing. MT: Writing – review & editing. QY: Supervision, Writing – review & editing. HH: Writing – review & editing.

Funding

The author(s) declared that financial support was not received for this work and/or its publication.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that Generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Chang, SM, Azin, M, and Demehri, S. Cutaneous squamous cell carcinoma: The frontier of cancer immunoprevention. Annu Rev Pathol. (2022) 17:101–19. doi: 10.1146/annurev-pathol-042320-120056,

PubMed Abstract | Crossref Full Text | Google Scholar

2. Que, KS, Zwald, OF, and Schmults, DC. Cutaneous squamous cell carcinoma: incidence, risk factors, diagnosis, and staging. J Am Acad Dermatol. (2018) 78:237–47. doi: 10.1016/j.jaad.2017.08.059,

PubMed Abstract | Crossref Full Text | Google Scholar

3. Alam, M, and Ratner, D. Cutaneous squamous-cell carcinoma. N Engl J Med. (2001) 344:975–83. doi: 10.1056/NEJM200103293441306,

PubMed Abstract | Crossref Full Text | Google Scholar

4. Garbe, C, Amaral, T, Peris, K, Hauschild, A, Arenberger, P, Basset-Seguin, N, et al. European consensus-based interdisciplinary guideline for melanoma. Part 1: Diagnostics: Update 2022. Eur J Cancer. (2022) 170:236–55. doi: 10.1016/j.ejca.2022.03.008,

PubMed Abstract | Crossref Full Text | Google Scholar

5. Claus, G, Amaral, T, Peris, K, Hauschild, A, Arenberger, P, Basset-Seguin, N, et al. European consensus-based interdisciplinary guideline for melanoma. Part 2: Treatment - Update 2022. Eur J Cancer. (2022) 170:256–84. doi: 10.1016/j.ejca.2022.04.018

Crossref Full Text | Google Scholar

6. Kawaguchi, M, Matsusue, E, Fujihara, T, Nakamura, K, Kaminou, T, Ohno, Y, et al. Prognostic value of 18F-FDG PET/CT and MRI features in patients with high-risk and very-high-risk cutaneous squamous cell carcinoma. Br J Radiol. (2022) 95:20211003. doi: 10.1259/bjr.20211003

Crossref Full Text | Google Scholar

7. Kawaguchi, M, Kato, H, Tomita, H, Hara, A, Suzui, N, Miyazaki, T, et al. Magnetic resonance imaging findings differentiating cutaneous basal cell carcinoma from squamous cell carcinoma in the head and neck region. Korean J Radiol. (2020) 21:325–31. doi: 10.3348/kjr.2019.0508,

PubMed Abstract | Crossref Full Text | Google Scholar

8. Bakos, RM, Blumetti, TP, Roldán-Marín, R, and Salerni, G. Noninvasive Imaging Tools in the Diagnosis and Treatment of Skin Cancers. Am J Clin Dermatol. (2018) 19:3–14. doi: 10.1007/s40257-018-0367-4,

PubMed Abstract | Crossref Full Text | Google Scholar

9. Dinnes, J, Bamber, J, Chuchu, N, Bayliss, SE, Takwoingi, Y, Davenport, C, et al. High-frequency ultrasound for diagnosing skin cancer in adults. Cochrane Database Syst Rev. (2018) 12:CD013188. doi: 10.1002/14651858.CD013188,

PubMed Abstract | Crossref Full Text | Google Scholar

10. Malvehy, J, and Pellacani, G. Dermoscopy, Confocal Microscopy and other Non-invasive Tools for the Diagnosis of Non-Melanoma Skin Cancers and Other Skin Conditions. Acta Derm Venereol. (2017) Suppl 218:22–30. doi: 10.2340/00015555-2720,

PubMed Abstract | Crossref Full Text | Google Scholar

11. Humphreys, TR, Shah, K, Wysong, A, Lexa, F, and MacFarlane, D. The role of imaging in the management of patients with nonmelanoma skin cancer: When is imaging necessary. J Am Acad Dermatol. (2017) 76:591–607. doi: 10.1016/j.jaad.2015.10.009,

PubMed Abstract | Crossref Full Text | Google Scholar

12. Warszawik-Hendzel, O, Olszewska, M, Maj, M, Rakowska, A, Czuwara, J, and Rudnicka, L. Non-invasive diagnostic techniques in the diagnosis of squamous cell carcinoma. J Dermatol Case Rep. (2015) 9:89–97. doi: 10.3315/jdcr.2015.1221,

PubMed Abstract | Crossref Full Text | Google Scholar

13. Aubry, S, Casile, C, Humbert, P, Jehl, J, Vidal, C, and Kastler, B. Feasibility study of 3-T MR imaging of the skin. Eur Radiol. (2009) 19:1595–603. doi: 10.1007/s00330-009-1348-z,

PubMed Abstract | Crossref Full Text | Google Scholar

14. Budak, MJ, Weir-McCall, JR, Yeap, PM, White, RD, Waugh, SA, Sudarshan, TA, et al. High-Resolution Microscopy-Coil MR Imaging of Skin Tumors: Techniques and Novel Clinical Applications. Radiographics. (2015) 35:1077–90. doi: 10.1148/rg.2015140142,

PubMed Abstract | Crossref Full Text | Google Scholar

15. Georgouli, T, Chang, B, Nelson, M, James, T, Tanner, S, Shelley, D, et al. Use of high-resolution microscopy coil MRI for depicting orbital anatomy. Orbit. (2008) 27:107–14. doi: 10.1080/01676830701558166,

PubMed Abstract | Crossref Full Text | Google Scholar

16. Kraff, O, Theysohn, JM, Maderwald, S, Kokulinsky, PC, Dogan, Z, Kerem, A, et al. High-resolution MRI of the human parotid gland and duct at 7 Tesla. Investig Radiol. (2009) 44:518–24. doi: 10.1097/RLI.0b013e3181b4c0cf,

PubMed Abstract | Crossref Full Text | Google Scholar

17. Mundada, P, Becker, M, Lenoir, V, Stefanelli, S, Rougemont, AL, Beaulieu, JY, et al. High resolution MRI of nail tumors and tumor-like conditions. Eur J Radiol. (2019) 112:93–105. doi: 10.1016/j.ejrad.2019.01.004,

PubMed Abstract | Crossref Full Text | Google Scholar

18. Lee, IS, Choi, JA, Oh, JH, Chung, JH, Jeong, HS, Hong, SH, et al. Microscopy coil for preoperative MRI of small soft-tissue masses of the hand and foot: comparison with conventional surface coil. AJR Am J Roentgenol. (2008) 191:W256–63. doi: 10.2214/AJR.07.3011,

PubMed Abstract | Crossref Full Text | Google Scholar

19. Tang, MX, Huang, RJ, Chen, JH, Sheng, M, Zhang, Z, Xing, J, et al. Clinical value of high-resolution dynamic contrast-enhanced (DCE) MRI in diagnosis of cutaneous squamous cell carcinoma. Skin Res Technol. (2020) 27:511–20. doi: 10.1111/srt.12978,

PubMed Abstract | Crossref Full Text | Google Scholar

20. Tang, M. Application of high-resolution MR imaging in the diagnosis of skin neoplastic lesions [dissertation]. Suzhou: Suzhou University (2020).

Google Scholar

Keywords: 3T-magnetic resonance imaging (3T-MRI), cutaneous squamous cell carcinoma (cSCC), cutaneous tumors, high-resolution magnetic resonance imaging (HR-MRI), magnetic resonance imaging (MRI), microcoil, preoperative assessment, tumor infiltration depth

Citation: Cao S, Zhan S, Tang M, Yu Q and Hu H (2026) High-resolution 3T-MRI with microcoil enhancement for preoperative evaluation of cutaneous squamous cell carcinoma: a case report and literature review. Front. Med. 13:1686516. doi: 10.3389/fmed.2026.1686516

Received: 15 August 2025; Revised: 05 January 2026; Accepted: 06 January 2026;
Published: 23 January 2026.

Edited by:

Isabel Pires, University of Trás-os-Montes and Alto Douro, Portugal

Reviewed by:

Giandomenico Roviello, University of Firenze, Italy
Giorgio Bogani, National Cancer Institute Foundation (IRCCS), Italy

Copyright © 2026 Cao, Zhan, Tang, Yu and Hu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Hongjie Hu, aG9uZ2ppZWh1QHpqdS5lZHUuY24=

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.