Diagnosis of Early Kidney Allograft Rejection: Influencing Factors in Metabolite-Based Urine Analysis

  • 1. Department of Nephrology, University Hospital Regensburg, Regensburg, Germany

  • 2. Department of Internal Medicine and Geriatrics, Krankenhaus Barmherzige Bruder Regensburg, Regensburg, Germany

  • 3. Numares AG, Regensburg, Germany

  • 4. Department of Surgery, University Hospital Regensburg, Regensburg, Germany

  • 5. Rheinisch-Westfalische Technische Hochschule Aachen Institute for Experimental Molecular Imaging, Aachen, Germany

Article metrics

View details

105

Views

The final, formatted version of the article will be published soon.

Abstract

Acute allograft rejection remains a major complication in kidney transplantation, highlighting the need for accurate and early diagnostic tools to enable prompt treatment. Standard diagnostic methods, such as serum creatinine monitoring, lack sufficient sensitivity and specificity. As a result, subclinical rejection may go undetected, or unnecessary biopsies may be performed, posing additional risks. Previously, a novel, non-invasive urine test based on metabolomic profiling was developed to detect renal allograft rejection. However, the early post-transplant period remains particularly challenging, as reliable biomarker-based detection in this critical window is not yet well established. This study, conducted within the UMBRELLA project, analyzed 682 urine samples from 109 kidney transplant recipients. The test utilized a specific urinary metabolite constellation based on alanine, citrate, lactate, and urea. A total of 29 clinical and transplant-related parameters, including donor and recipient characteristics, ischemia times, and donor type, were evaluated for their effect on the test's ability to detect biopsy-confirmed rejection within the first 14 days after transplantation. Univariate analysis identified ten significant confounding factors, including lower residual urine volume before transplantation, reduced eGFR, use of induction therapy, longer warm and cold ischemia times, deceased donor status, younger recipient age, and certain HLA mismatches. Multivariate analysis confirmed the relevance of living donation. Subgroup analysis revealed the highest diagnostic accuracy in recipients of living donor kidneys, with an AUC of 0.720 (95% CI: 0.62–0.82), followed by recipients with a short warm ischemia time (<30 minutes), who achieved an AUC of 0.702 (95% CI: 0.61–0.79). Clinical complications often coincided with abnormal metabolite test results. In conclusion, this study underscores the importance of considering donor type and ischemia times when interpreting urinary metabolite constellations for rejection monitoring in the early post-transplant period. The findings suggest a distinct metabolic profile in recipients of deceased donor kidneys within the first two weeks after transplantation. Understanding these influencing factors may enhance the accuracy of non-invasive rejection detection and support timely clinical interventions to improve patient outcomes.

Summary

Keywords

allograft rejection, Biopsies, Kidney Transplantation, Metabolomics,, Urine test

Received

18 August 2025

Accepted

03 February 2026

Copyright

© 2026 Wiesner, Schiffer, Putz, Robertson, Mark, Reichelt-Wurm, Schmidt, Schwaeble Santamaría, Banas and Banas. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Miriam C Banas

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Share article

Article metrics