From Ciliary Sulcus Asymmetry to Vault Prediction: An hSTS-Based Approach to Individualized Sizing of Implantable Collamer Lenses in Myopic Eyes
Zeyu Zhu 1,2,3
Miao Diao 1
Chunhao Fu 1
Wanling Wu 1
Guiying Zhang 1,2,3
Jingyuan Tian 1
Chuchu Zhong 4
Lingling Zhong 5
Ying Zhu 6,7,8,9
Jun Li 1
1. He Eye Specialist Hospital, Shenyang, China
2. The Second Hospital of Dalian Medical University, Dalian, China
3. He University, Shenyang, China
4. College of Physics and Communication Electronics, Jiangxi Normal University,, Nanchang, China
5. Fuzhou Experimental School, Fuzhou, China
6. Dalian Third People’s Hospital Affiliated to Dalian University of Technology, Dalian, China
7. Dalian Municipal Eye Hospital, Dalian, China
8. Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Dalian, China
9. Technology Engineering Research Center, Dalian, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Abstract
Objective: To investigate the distribution and correlations of horizontal and vertical sulcus-to-sulcus diameters (hSTS/vSTS) in myopic eyes with different refractive errors, and to develop a predictive model for postoperative vault after posterior chamber phakic implantable collamer lens (ICL) implantation based on key anterior segment parameters. Methods: This retrospective study included two non-overlapping cohorts of myopic patients who underwent ICL implantation at a single tertiary eye hospital. The morphology cohort comprised 244 eyes, classified into moderate, high, and extreme myopia groups according to spherical equivalent (SE). Ultrasound biomicroscopy (UBM) was used to measure hSTS and vSTS; inter-group comparisons and correlation analyses were performed. The model development cohort included 44 patients (72 eyes). In addition to STS, preoperative anterior segment parameters (corneal curvature, horizontal corneal diameter, anterior chamber depth, lens thickness, and axial length) were recorded, and ICL size was selected according to the STAAR nomogram. One month postoperatively, the vault was measured using anterior segment optical coherence tomography. Univariate correlation and stepwise multiple linear regression were applied to identify factors and derive a prediction formula. Results: The ciliary sulcus was predominantly vertically elliptical in the overall population (vSTS > hSTS). In the extreme myopia group, both hSTS and vSTS were significantly larger than in moderate and high myopia groups, with a greater vSTS−hSTS difference (0.63 ± 0.38 mm, all P < 0.05). SE correlated weakly and negatively with hSTS (r = −0.177, P = 0.006) and vSTS (r = −0.243, P < 0.001), while hSTS and vSTS were strongly positively correlated (r = 0.781, P < 0.001). In the modeling cohort, stepwise regression identified hSTS and ICL size as independent predictors of vault (adjusted R² = 0.657), yielding the formula: vault (µm) = −2286.216 − 164.416 × hSTS (mm) + 375.487 × ICL size. Conclusions: The higher myopic refractive error is associated with a more pronounced vertically elliptical ciliary sulcus. Routine measurement of both vertical and horizontal STS, combined with a vault prediction model based on hSTS and ICL size, may facilitate individualized ICL sizing, improve vault predictability, and enhance surgical safety.
Summary
Keywords
Implantable collamer lens (ICL), Myopia, Personalized surgery, sulcus-to-sulcus, Ultrasound biomicroscopy (UBM), Vault
Received
07 December 2025
Accepted
13 February 2026
Copyright
© 2026 Zhu, Diao, Fu, Wu, Zhang, Tian, Zhong, Zhong, Zhu and Li. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ying Zhu; Jun Li
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.