Skip to main content

EDITORIAL article

Front. Bioeng. Biotechnol., 12 September 2022
Sec. Biosensors and Biomolecular Electronics
Volume 10 - 2022 | https://doi.org/10.3389/fbioe.2022.1008603

Editorial: Integrated biosensors towards clinical and point-of-care diagnostics

  • 1FIT Freiburg Center for Interactive Materials and Bioinspired Technologies, University of Freiburg, Freiburg, Germany
  • 2Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
  • 3Laboratory of Bio-physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India
  • 4Biophotonic Nanosensors Laboratory, Centro de Investigaciones en Óptica León, Guanajuato, Mexico

Biosensing devices such as lateral flow assays, blood glucose test strips or wearable continuous glucose monitoring systems have had a great impact on healthcare for more than half a century and have already improved our living standards. In particular, biosensors allow us to measure clinically relevant biomarkers from various sample matrices (including whole blood, plasma, saliva, or urine) in a fast, cost-effective, and user-friendly manner. Hence, biosensing technologies can provide vital information related to the propensity for illness or the status of a disease, or its treatment monitoring. However, there are still some challenges, especially regarding the sample Research Topic and preparation as well as the biosensing performance of diagnostic devices (Ates et al., 2021).

To further assess the potential of this technology, researchers are pushing forward the frontiers of integrated biosensors, combining the sample Research Topic, preparation, analysis, and data evaluation, to create “sample-in-answer-out” diagnostic devices. Such integrated solutions for biosensing could enable real-time, highly sensitive, and selective quantification of various biomolecules within clinically relevant body fluids in a smart, sustainable, interoperable, and portable manner.

This Research Topic gathers innovative approaches for integrated biosensing systems conceived from colleagues located in diverse parts of the world, including Australia, China, Denmark, Taiwan, the United Kingdom, and the United States. Several clinically relevant agents are targeted, including respiratory viruses (Fan et al.), interleukin-6 (a biomarker of inflammatory associated diseases) (Rahbar et al.), biomarkers related to gastric cancer (Liu et al.), dengue serotypes (Moser et al.), SARS-CoV-2 virus (Lin et al.; Ngoc et al.), and carbohydrate antigen 50 (a non–organ-specific tumor biomarker for screening several cancers) (Liu et al.). All of them were presented with (potential) clinical applications at the point-of-care. In particular:

Fan et al. integrated recombinase aided amplification (a novel isothermal amplification method targeting the genetic material of various pathogens) and quantitative polymerase chain reaction (qPCR) in order to detect respiratory viruses (ADV3 and ADV7). A conventional qPCR apparatus was employed to perform nucleic acid amplification and highly specific detection in a single tube within 1 h.

Rahbar et al. reported a paper-based device where the silver amplification technique was integrated in a lateral flow immunoassay to enhance colorimetric signals, leading to a reliable, low-cost, and user-friendly platform for the detection of interleukin-6.

Liu et al. reviewed the state of the art of Raman spectroscopy as an emerging label-free technology for gastric cancer diagnosis. The authors highlight that the integration of a Raman fiber optic probe and endoscope facilitates real-time in vivo detection of cancer development. In this context, limiting factors to be addressed are also spotted, including those related to equipment, clinical sensitivity/specificity, and Raman data analysis.

Lin et al. integrated a molecular diagnostic device with microfluidic chips and dual temperature modules. This platform offers detection of the genetic material of pathogens in less than 24 min. The clinical sensitivity of the platform was demonstrated by analyzing clinical samples of sputum and stool, thereby enabling a rapid, reliable, and user-friendly device for the detection of pathogens such as SARS-CoV-2.

Liu et al. implemented a miniaturized chemiluminescence immunoassay analyzer that obviates the skills of particularly trained personnel. For the demonstration of the proof-of-concept, carbohydrate antigen 50 was detected using this platform. The analyzer, which can detect 60 samples per hour, was proven technically sound with clinical samples, offering an alternative to performing cancer-related diagnostics in low-resource settings.

Ngoc et al. developed a point-of-care system for the fast and real-time detection of SARS-CoV-2. The team took advantage of fluorescent signals and Arduino platforms (compatible with commercially available open-source hardware-software and off-the-shelf electronic components) to control real-time reverse transcriptase loop-mediated isothermal amplification reactions for the quantitative detection of SARS-CoV-2 viruses.

Moser et al. introduced a smartphone-connected portable lab-on-a-chip platform for the quantitative detection of two dengue serotypes. A smartphone app synchronizes the obtained results in real-time with a secure cloud server hosted by Amazon Web Services for epidemiological surveillance. In addition, the portable character and geo-tagging abilities of the platform were proven to be technically sound in low-resource settings employing a pilot study performed between United Kingdom and Taiwan.

We hope this article Research Topic contributes valuable insights into the exciting field of integrated biosensors with comprehensive knowledge of fundamentals, materials, technologies, and their point-of-care applications. This in turn will help researchers to conduct research beyond the state-of-the-art in this field.

Author contributions

EM-N, CD, and PC conceived the idea and coordinated the Research Topic. CD, EM-N, and PC co-edited this Research Topic and approved the submitted version of the Editorial Article. All authors contributed to the article and approved the submitted version.

Funding

EM-N. acknowledges financial support from CONACYT (Mexico, grant number 376135) and IDEA-GTO (grant number MA-CFINN0997). PC acknowledges the financial support from ICMR, India (Department of Health Research Grant Number: GIA/2020/001025).

Acknowledgments

We acknowledge and thank the authors who contributed to this Research Topic. We are also grateful to the involved Reviewers for their professional insights in reviewing this Research Topic.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Ates, H. C., Brunauer, A., von Stetten, F., Urban, G. A., Güder, F., Merkoçi, A., et al. (2021). Integrated devices for non-invasive diagnostics. Adv. Funct. Mat. 31, 2010388. doi:10.1002/adfm.202010388

CrossRef Full Text | Google Scholar

Keywords: health 4.0, on-site detection, sample preparation, microfluidics, non-invasive diagnostics, point-of-care testing

Citation: Dincer C, Chandra P and Morales-Narváez E (2022) Editorial: Integrated biosensors towards clinical and point-of-care diagnostics. Front. Bioeng. Biotechnol. 10:1008603. doi: 10.3389/fbioe.2022.1008603

Received: 01 August 2022; Accepted: 16 August 2022;
Published: 12 September 2022.

Edited and reviewed by:

Guozhen Liu, The Chinese University of Hong Kong, Hong Kong SAR, China

Copyright © 2022 Dincer, Chandra and Morales-Narváez. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Can Dincer, dincer@imtek.de; Pranjal Chandra, pranjal.bce@iitbhu.ac.in; Eden Morales-Narváez, eden@cio.mx

Download