Skip to main content

REVIEW article

Front. Oncol., 09 March 2017
Sec. Genitourinary Oncology
This article is part of the Research Topic Controversies and Perspectives in the Use of Postoperative Radiotherapy for Prostate Cancer View all 10 articles

Post-Prostatectomy Image-Guided Radiotherapy: The Invisible Target Concept

\r\nFlorent VilotteFlorent Vilotte1Mickael AntoineMickael Antoine2Maxime BobinMaxime Bobin1Igor LatorzeffIgor Latorzeff3Stphane SupiotStéphane Supiot4Pierre RichaudPierre Richaud1Laurence ThomasLaurence Thomas1Nicolas LeducNicolas Leduc1Stephane GurifStephane Guérif5Jone Iriondo-AlberdiJone Iriondo-Alberdi6Renaud de CrevoisierRenaud de Crevoisier7Paul Sargos*\r\nPaul Sargos1*
  • 1Department of Radiotherapy, Institut Bergonié, Bordeaux Cedex, France
  • 2Department of Medical Physics, Institut Bergonié, Bordeaux Cedex, France
  • 3Department of Radiotherapy, Groupe ONCORAD, Clinique Pasteur, Toulouse, France
  • 4Department of Radiotherapy, Institut de Cancérologie de L’Ouest René Gauducheau, Nantes, France
  • 5Department of Radiotherapy, CHU de Poitier, Poitiers, France
  • 6Institut Bergonié, Bordeaux Cedex, France
  • 7Department of Radiotherapy, Centre Eugène-Marquis, Rennes, France

In the era of intensity-modulated radiation therapy, image-guided radiotherapy (IGRT) appears crucial to control dose delivery and to promote dose escalation while allowing healthy tissue sparing. The place of IGRT following radical prostatectomy is poorly described in the literature. This review aims to highlight some key points on the different IGRT techniques applicable to prostatic bed radiotherapy. Furthermore, methods used to evaluate target motion and to reduce planning target volume margins will also be explored.

Introduction

Intrapelvic anatomical variations occurring between radiotherapy fractions (inter-fractions) or during the fraction (intra-fraction), corresponding to movement and/or deformation of target volumes and/or adjacent organs at risk (OAR), can result in differences between the distribution of the pretreatment-delivered dose and the initially planned distribution. If not corrected, these variations can particularly cause severe overdose to healthy tissues and underdose to target tumor, leading to an increased risk both of toxicity and of local recurrence (1). In this context, radiotherapy following radical prostatectomy represents a challenge for the radiation oncologist. The absence of a visible target within a complex pelvic anatomical region requires, firstly, accurate target volume delineation and, secondly, a qualitative approach to ensure radiation delivery.

Regarding the first condition, to date, only four articles have published consensus guidelines to delineate the clinical target volume (CTV) corresponding to the prostatectomy bed. According to the Radiation Therapy Oncology Group (RTOG) Consensus Guidelines, CTV can be defined as “the tissue volume at risk of subclinical microscopic and macroscopic tumor growth for the prostate fossa following radical prostatectomy” (25). Even if such definition results in lower interobserver variability in the CTV delineation (6), the characterization of the volume of interest still differs from one article to another. This uncertainty arises from both the anatomical modifications after surgery and the difficulty in using the data on preoperative target volume localization. In turn, with the development of intensity-modulated radiation therapy (IMRT), the possibility of increasing the dose to the target while sparing the surrounding OARs has led to significantly improving the biochemical control for localized prostate cancers (79). In the postsurgery setting, the prescribed dose has been shown to be correlated to a biochemical control with both adjuvant radiotherapy and salvage radiation therapy (1013). The use of IMRT for the irradiation of the prostatectomy bed has also allowed reducing significantly late grade ≥2 gastrointestinal toxicity compared to 3D conformal radiation therapy (14, 15). Nevertheless, with the increase of elderly patients, the choice of treatment must be discussed, and the toxicity threshold re-defined (16). If clinical benefits appear to be obvious with IMRT, the goal of image-guided radiation therapy (IGRT) is to ensure an effective treatment delivery by precisely targeting the radiation to the tumor. The use of planning target volume (PTV), which takes into consideration the uncertainties linked to patient positioning and target volume movements and deformation during treatment, becomes a determining element to guarantee the quality of radiation therapy in the postsurgery setting (17). Dosimetry inaccuracies resulting from positioning errors may decrease biochemical control (18) and increase toxicity if the OARs are not spared (1921). Prostatectomy bed movements and/or deformations are mainly dictated by changes in the volume and shape of rectum and bladder (18, 22). The aim of this review is to provide an overview of prostatectomy bed motion (PBM) and/or deformation in post-prostatectomy radiotherapy. Repositioning imaging techniques used in IGRT and potential corrective, preventive, and stabilizing measures will also be explored.

Concepts and Strategy for IGRT of the Prostatectomy Bed

What Errors Must Be Taken into Account?

Image guidance is defined as a 3D adjustment of the target position such that the treatment target and the planned target positions correspond. IGRT allows tracking the position of the patient and the target isocenter, of the PTV and of adjacent OARs, as well as analyzing possible deformations for those volumes during the radiotherapy schedule. Minimizing these repositioning errors could lead to reduced PTV margins, which facilitates OAR sparing. Positioning errors can be divided into three main categories:

– Setup errors (SUEs) correspond to the necessary displacements to align bony anatomy on the electronic portal image and the digitally reconstructed radiograph, after patient positioning using skin landmarks.

– PBM corresponds to target volume movement relative to bony anatomy.

– Total positioning error (TPE) is the sum of the two previous errors.

Both systematic (mean value of the displacement) and random (SD of the displacement) errors can be calculated, the systematic error impacting strongly in dose variations (17). In addition to displacement uncertainties, the prostatectomy bed may present large deformations, which are less observed with the intact prostate. Such anatomical variations are much more complex to quantify and to take into account than displacements, unless using elastic registration methods.

How to Evaluate and Reduce These Errors?

The different IGRT techniques allow viewing the tumor either directly through 2D or 3D images, or indirectly using markers or bony structures closely related to the tumor and/or OAR motion. Table 1 presents potential advantages and limitations of prostatectomy bed IGRT techniques. Table 2 synthetizes the results of main IGRT studies evaluating PBM.

TABLE 1
www.frontiersin.org

Table 1. Description of post-prostatectomy image-guided radiotherapy (IGRT) techniques.

TABLE 2
www.frontiersin.org

Table 2. Results of IGRT main studies evaluating prostatectomy bed movements.

Image-Based Positioning Techniques in Post-Prostatectomy IGRT: What Results with Which Technique?

Bony Anatomy Alignment Captured by 2D Imaging

Klayton et al. studied PBM using electromagnetic transponders in order to evaluate the quality of bony anatomy as a localization method using 2D imaging. After patient positioning based on laser and skin landmarks, the evaluation of target volume isocenter position was carried out with electromagnetic transponders. Deviation of the isocenter position in this case corresponded to TPE. Once the first alignment completed, 2D kv–kv imaging was performed. PBM was estimated by measuring the 3D shifts needed to align bony anatomy. For 9% of fractions, anterior–posterior (AP) direction PBM exceeded 5 mm. In 21% of fractions, a repositioning in the superior–inferior (SI) direction was necessary. Finally, 70% of patients were repositioned at least once during treatment. According to the authors, patient setup margins were 5 mm in left–right (LR), 13 mm in SI, and 9 mm in AP based on 2D kv–kv image guidance. The results of this study are summarized in Table 2. 2D imaging on its own only takes into consideration SUEs, omitting the contribution of the PBM component and of volume variations. As a result, it is not adapted to estimate prostatectomy bed movements (23).

Soft Tissue Anatomy Alignment Evaluated by 3D Imaging

Ost et al. analyzed a series of 547 cone beam computed tomography (CBCT) daily images from 15 patients successively treated by post-prostatectomy radiotherapy. PBM was determined considering the motion of the anterior rectal wall. Systematic inter-fraction movements in the LR, SI, and AP were 0.44, 0.92, and 2.50 mm, respectively. Similarly, random deviations of 0.99 mm in LR, 1.38 mm in SI, and 2.32 mm in AP axes were observed. These results, based on imaging modalities that take into account PBM, emphasize the prevalence of AP shifts of the prostatectomy bed, as reported for prostate, and highlight that an approach relying only on bony anatomy appears insufficient (24). Despite the larger TPE described with 2D kv–kv imaging compared to CBCT, no correlation was found between TPE and acute toxicity (25). Using computed tomography (CT)-on-rails IGRT on 10 patients, Liu et al. analyzed volume variations and deformations of CTV, rectum, and bladder. They showed daily volume variations of 75–116% for CTV, 50–270% for rectum, and 30–180% for bladder compared to planning CT (26).

Soft Tissue Anatomy Alignment Evaluated by Ultrasonography (US)

Studies on the use of US for post-prostatectomy IGRT are scarce. Chinnaiyan et al. analyzed PBM in six consecutive patients by comparing transabdominal US (taking the bladder neck as reference for post-prostatectomy fossa localization) with 2D imaging. Regarding repositioning accuracy, there was a difference of 5 ± 3 mm between the two techniques in favor of US imaging. This result supports the use of the US-IGRT for daily pretreatment patient repositioning as stated by the authors (27).

A comparison of transabdominal US and CBCT imaging was carried out by Fargier-Voiron et al. in 11 post-prostatectomy patients. The differences between US and CBCT shifts were −0.7 ± 4.3, 1 ± 4.6, and 0.2 ± 2.7 mm in AP, SI, and LR axes, respectively. For these three directions, the shift agreements (percentage of sessions for which the shift difference between the two modalities is below or equal to 5 mm) between US and CBCT were 80.2, 86.8, and 96.2%, respectively. During radiotherapy schedule, 20% of the US images were excluded due to poor quality, the authors concluding that transabdominal US imaging alone should not be used as IGRT modality (28). The same group evaluated a novel method of transperineal US imaging (Clarity, Elekta®) that offers a better image quality (100 vs 80% exploitable), a reduction of inter-operator variability, and a consistent probe pressure during examination. Shift agreements at ±5 mm improved to 90.3, 85, and 97.6% in AP, SI, and LR directions, respectively, leading the authors to propose this method as a non-ionizing alternative to CBCT (29).

What PTV Margins Are Used with Which IGRT Technique?

It appears essential to adapt PTV margins to the IGRT techniques used by the physician. According to the literature, these margins range from 3 to 10 mm (30). For example, in cases of bony anatomy alignment, PTV margins vary from 5 to 15 mm. Indeed, recommendations for target volume definitions differ substantially: at least 5 mm according to the European Organization For Research and Treatment of Cancer, 10 mm according to the Australian and New Zealand Radiation Oncology Genito-Urinary Group (in case of rectal dose–volume histogram limitations, a reduction of the posterior PTV margin expansion to 5 mm is possible), from 6 to 15 mm according to the RTOG study 0534, and from 5 to 15 mm according to the recommendations from the Groupe d’Etude des Tumeurs Uro-Génitales (25).

Can IGRT be Improved Using Prostatectomy Bed Repositioning Markers?

Surgical Clips As Markers

Similar to prostate radiotherapy, several studies have analyzed the use of surgical clips during post-prostatectomy irradiation (3135). Sandhu et al. studied two orthogonal kv images to localize the prostatectomy bed in 26 patients using surgical clips as target volume landmarks. In total, 692 images were analyzed. Target volume displacements were mainly related to SUE. PBM was most prominent in the AP axis, with an average magnitude of 2.7 ± 2.1 mm. PBM in the SI and LR directions was 2.4 ± 2.1 and 1 ± 1.7 mm, respectively (31). Series using 3D imaging with the same approach have also reported the prominence of the displacements in the AP direction (2–5 mm) compared to those in the SI (0.5–2.5 mm) and lateral (less than 1 mm) directions (33, 35). Cavalieri et al. used surgical clips as markers to analyze the repositioning of 17 consecutive patients using CT-on-rail IGRT. Systematic errors led to displacements ranging from 6 to 10 mm, mainly in the AP dimension (5.5%) (36). Hence, the use of surgical clips as markers to guide radiotherapy could reduce the impact of PBM. Figure 1 presents an example of CBCT for post-prostatectomy radiotherapy.

FIGURE 1
www.frontiersin.org

Figure 1. Example of post-prostatectomy image-guided radiotherapy. Initial computed tomography (CT) scan and cone beam computed tomography (CBCT) used for analysis of repositioning show a good correlation for rectum, bladder, and clinical target volume.

Gold Fiducial As Markers

Historically used for prostate radiotherapy, fiducial markers facilitate the detection of the CTV. Additionally, their radiopacity allows using low ionizing imaging modalities. Even though the transrectal implantation of gold fiducial markers under US guidance is an invasive technique, very few complications have been described. Langenhuijsen et al. implanted three gold markers (two at the dorsal bladder base and one next to the anastomosis) in 77 consecutive post-prostatectomy patients and showed the feasibility of the procedure (37). Fortin et al. reported a reduction of inter-operator variability during online and offline localization compared to surgical clips. Furthermore, fiducial markers resulted in a repositioning quality greater than that of surgical clips, often out of the prostatectomy bed and closely clustered, limiting daily SUE and errors related to PBM (38). After implanting gold fiducial markers into the prostate bed, daily CBCT of 13 patients was analyzed by Ålander et al. They reported displacements (mean ± SD) of 0.0 ± 0.5 mm in the LR, 0.7 ± 2.1 mm in the SI, and 0.8 ± 1.6 mm in the AP directions, which were deemed non-significant by the authors (39). In a similar manner, Schiffner et al. used 2D imaging for 10 patients. Positioning errors of more than 5 mm in the LR, SI, and AP axes were observed in 14.1, 38.7, and 28.2% of the cases, respectively, mainly related to SUE, while PBM remained modest. Over the total duration of treatment, gold seed fiducial migration was small (0.4 mm on average) (40). Confirming the difficulties in matching predominant in the AP direction, also reported with the use of surgical clips, gold fiducial markers with CBCT or kv–kv imaging appear to be more robust despite their invasive nature.

Is There a Need for Global Positioning System for Prostate Bed Radiotherapy?

The Calypso® 4D Localization System commercialized by Varian enables real-time intra-fraction localization and tracking with three electromagnetic transponders (41). Already studied in the prostate irradiation setting (42), intra-fraction motion was analyzed in 20 patients undergoing post-prostatectomy radiotherapy. A displacement of more than 5 mm during 30 s was reported for at least 11% of delivered fractions. For 16 (80%) patients, PBM was observed in the SI and AP axes, and the 5-mm threshold margin was exceeded in a third of cases. Interruptions for repositioning were reported in 15% of the delivered fractions. Over the treatment course, only 25% of the patients were repositioned more than five times, and 30% of the patients did not need any repositioning. Further studies are needed in order to select patients that can benefit most from this approach (23).

Preventive, Corrective, and Stabilizing Approaches to Limit PBM Due to Rectal and Bladder Movements

Prostatectomy bed motion is essentially correlated with adjacent OAR displacements or volume variations. Disregarding rectal distension could result in an increase of up to 18 or 24 mm of posterior margins and, consequently, in dosimetry inaccuracies (43, 44). Figure 2 illustrates a case of inadequate rectal filling during treatment. Concerning bladder volume variations during treatment, Fiorino et al. detected a ratio between the largest and smallest volume of 3.8 (range 1.9–8.3), which had an impact on PTV (18). Preventive, corrective, and stabilizing approaches to limit PBM due to rectal and bladder movements are presented below.

FIGURE 2
www.frontiersin.org

Figure 2. Example of a patient treated by prostate-bed radiotherapy with inadequate rectal filling during image-guided radiotherapy (3D image-based positioning).

Bladder Filling

Variations in bladder volume are frequent in both post-prostatectomy and non-operated patients, with a trend in decreasing volume during treatment (18, 45). These bladder volume variations could impact on PTV coverage (22). Bell et al. showed that bladder filling variations of >2, ±1, or <2 cm happened in 3.4–56.2% of cases, with most size changes occurring in the AP direction. These variations resulted in potential geographic misses (movement of surgical clips greater than 0.5 cm posteriorly, 1 cm in other directions). Further, if the bladder or rectum remained within 1 cm of the planned size, less than 10% of the images revealed a geographic miss (46). These results demonstrate the importance of a consistent and stable bladder and rectal volume during treatment. Patients at risk of variations should be detected early in order to offer them the most secure treatment.

Diet Recommendations

Studies on diet changes, in order to prevent the production of gas, primarily in cases of prostate irradiation, have led to conflicting results. Smitsmans et al. compared the CBCT of 26 patients irradiated following a diet poor in fibers and 23 patients following no diet. Diet was beneficial, preventing the presence of stool, gas pockets, and moving gas pockets during radiotherapy, and resulted in a reduction of inter-fraction and intra-fraction motion (47). On the contrary, Lips et al. evaluated the same type of diet in 105 patients and observed an increase in inter-fraction prostate motion for patients following the dietary protocol. The median of the average inter-fraction motion ranged from 2.53 mm in the non-diet group to 3 mm in the diet group (48). Using magnetic resonance imaging (MRI) as IGRT technique, Nichol et al. evaluated an antiflatulent diet and a milk of magnesia-based laxative in 42 patients and did not observe a reduction in inter-fraction prostate motion. This study demonstrated that moving gas only (56%) and moving gas and stool (18%) accounted for 74% of inter-fraction movements (49). Concerning inter-fraction motion, Oates et al. could not demonstrate any significant difference in favor of a diet associated to psyllium but observed a trend toward rectal volume reduction (50). A randomized trial including 40 patients studied the use of probiotics, such as Lactobacillus acidophilus, and reported a significant reduction in rectal volume variations over the treatment course (51). Evaluations on other molecules preventing the production of intestinal gas, such as the alpha-galactosidase, are ongoing (52). Although encouraging, these results need to be further validated.

Strategies for Rectal Emptying

Several studies have analyzed the efficacy of different strategies to empty rectal gases in order to minimize prostate motion. Yahya et al. compared three strategies to reduce rectal distension: (i) the use of microenema before each treatment; (ii) a recommended dietary protocol; and (iii) no bowel preparation or dietary advice. After the analyses of the CBCT scans of these three groups, a reduction of almost half of scans showing geometric miss (shifts ≥5 mm) was observed in the microenema group compared to the other two (53). Ogino et al. analyzed the impact of rectal gas self-evacuation using the index finger on the average prostate and seminal vesicle motion in 76 patients. A significant reduction (0.3–4.4 mm) of the prostate and the seminal vesicle displacement was observed (54). Diot et al. analyzed in a series of 17 post-prostatectomy patients an intervention involving the use of a rectal catheter to deflate the rectum, evacuation of stools, and adjustment of bladder filling. These corrective measures were applied in cases of rectal or bladder wall displacements larger than 5 mm. The median number of interventions per patient was 5. The procedure led to a reduction in the motion of the target volume during radiotherapy schedule, which dropped from 45 to 21% in the AP, from 7 to 4% in the SI, and from 7 to 8% in the LR direction. These measures, more effective for AP displacements, decreased the PTV margin by 3.3 mm (55). Nevertheless, no benefit in terms of dosimetry was observed with conventional fractionation both for PTV coverage or OAR sparing. These results suggest that daily CBCT localization alone could be enough to take into consideration the motion of the target volume. For hypofractionated treatments, however, the rectal emptying interventions could have a greater impact in terms of dosimetry (56).

Endorectal Balloons (ERBs)

Rectal filling has been identified as predictive of prostate motion by cine-MRI studies assessing intra-fraction movements (57, 58). The introduction of an ERB could optimize the rectal volume and conformation, minimizing at the same time target volume positioning errors.

In a comparative study on 14 post-prostatectomy patients, 7 of which were treated with ERB, shift agreement of CTV and rectal volumes with planning CT were improved by 4 and 21%, respectively. This stability is also reflected in a reduction of median motion, particularly the AP margin of the lower part of the CTV motion of 0.43 ± 0.45 cm without ERB to 0.37 ± 0.27 cm with ERB. The lower part of CTV moves dropped from 0.16 ± 0.17 to 0.11 ± 0.11 cm. ERB also reduced the impact of vesicle filling on shift agreement (59). Jameson et al. analyzed the use of ERB on post-prostatectomy patients and observed no significant dosimetry improvements in terms of PTV coverage or OAR sparing with the use of ERB (60). On the other hand, some dosimetry studies have demonstrated an improvement in rectum and anal canal sparing, mainly for intermediate and high doses, with the use of ERB. Smeenk et al. compared the dosimetry in 20 patients that had undergone surgery, with or without ERB, for a prescription dose of 70 Gy. Regarding rectal dose–volume histogram, rectal V30 and V40 dropped by 8 and 5%, respectively. CTV volume was considerably reduced in the presence of ERB (117 ± 27 vs 110 ± 20 cc), but no correlation could be found between this volume and rectal sparing (61, 62).

Concerning the clinical impact, Ishiyama et al. carried out a retrospective study on 107 patients treated by salvage radiotherapy with ERB at a dose of 70 Gy in 32 fractions. Late gastrointestinal and genitourinary toxicities of grade 2 were reported in 6 and 13% of patients, respectively, and grade 3 in 3 and 6% of patients, respectively (63).

The development of new stabilizers, such as the ProSpare of the Institute of Cancer Research in London, opens up a new study field in this domain. ProSpare proposes to add radio-opaque markers that allow a better identification of the anterior rectal wall, as well as ventilation holes for the evacuation of rectal gases (64, 65). A phase II study is currently ongoing (postoperative ProSpare).

Spacers

The injection or implantation of a biodegradable substance in the anterior perirectal fatty space was studied for patients receiving prostate radiotherapy (66). This approach allows displacing the prostate away from the rectal wall reducing the rectal volume exposed to high level doses (67). Pinkawa et al. found a significant reduction of systematic posterior displacements superior to 6.5 mm (dropping from 27 to 0%) (6871). For prostate radiotherapy, a wide range of spacers have been studied, and the prostate-rectum separation varied from 7 to 20 mm depending on the technique used, reducing the rectal V70 by about 43–84% (66, 72, 73). Spacer utilization has been less explored in the postoperative radiotherapy setting. Pinkawa et al. published a case report on a patient presenting a macroscopic recurrence at the uretho-vesical anastomosis. Polyethylene glycol spacer injection allowed them to create a space of more than 1 cm between the recurrence site and the rectal wall. This led to significantly reducing the rectal V70, V60, and V50 compared to treatment planning based on computer tomography. PTV dose prescription was 76 Gy, and a good global tolerance led the authors to propose this approach for specifically selected patients (74).

Conclusion

Radiotherapy of the prostatectomy bed in an adjuvant or salvage setting, mostly under IMRT and IGRT conditions, constitutes a routine situation for the clinician. 2D imaging modalities are in themselves insufficient to evaluate target volume displacement and deformation, and the soft tissue anatomy alignment using a 3D approach appears crucial. The utility of fiducial markers or surgical clips, as well as preventive, corrective, or stabilizing measures, has been shown to limit these displacements. At present, due to lack of substantial literature, reducing the margin that constitutes the PTV to less than 5 mm (independent of the IGRT technique used) is not recommended; however, an anisotropic approach can be justified in view of the predominant displacements in the AP dimension on the prostatectomy bed. The development of MRI and of tracking strategies could therefore improve imaging quality and, as a result, increase the precision of soft tissue anatomy alignment. The trend toward dose augmentation and hypofractionation requires not only precise target localization to ensure dose distribution but also tolerance and efficacy. Confirming the impact of IGRT by means of larger studies seems necessary with, notably, an evaluation of patient-reported outcomes.

Author Contributions

Drafting the article: FV and PS. Critical revision of the article; final approval of the version to be published: FV, MA, MB, IL, SS, PR, LT, NL, SG, JI-A, RC, and PS.

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

1. Gill S, Isiah R, Adams R, Dang K, Siva S, Tai KH, et al. Conventional margins not sufficient for post-prostatectomy prostate bed coverage: an analysis of 477 cone-beam computed tomography scans. Radiother Oncol (2014) 110(2):235–9. doi:10.1016/j.radonc.2013.12.004

CrossRef Full Text | Google Scholar

2. Poortmans P, Bossi A, Vandeputte K, Bosset M, Miralbell R, Maingon P, et al. Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group. Radiother Oncol (2007) 84(2):121–7. doi:10.1016/j.radonc.2007.07.017

CrossRef Full Text | Google Scholar

3. Wiltshire KL, Brock KK, Haider MA, Zwahlen D, Kong V, Chan E, et al. Anatomic boundaries of the clinical target volume (prostate bed) after radical prostatectomy. Int J Radiat Oncol Biol Phys (2007) 69(4):1090–9. doi:10.1016/j.ijrobp.2007.04.068

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Michalski JM, Lawton C, El Naqa I, Ritter M, O’Meara E, Seider MJ, et al. Development of RTOG consensus guidelines for the definition of the clinical target volume for postoperative conformal radiation therapy for prostate cancer. Int J Radiat Oncol Biol Phys (2010) 76(2):361–8. doi:10.1016/j.ijrobp.2009.02.006

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Sidhom MA, Kneebone AB, Lehman M, Wiltshire KL, Millar JL, Mukherjee RK, et al. Post-prostatectomy radiation therapy: consensus guidelines of the Australian and New Zealand Radiation Oncology Genito-Urinary Group. Radiother Oncol (2008) 88(1):10–9. doi:10.1016/j.radonc.2008.05.006

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Mitchell DM, Perry L, Smith S, Elliott T, Wylie JP, Cowan RA, et al. Assessing the effect of a contouring protocol on postprostatectomy radiotherapy clinical target volumes and interphysician variation. Int J Radiat Oncol Biol Phys (2009) 75(4):990–3. doi:10.1016/j.ijrobp.2008.12.042

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Kupelian PA, Ciezki J, Reddy CA, Klein EA, Mahadevan A. Effect of increasing radiation doses on local and distant failures in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys (2008) 71(1):16–22. doi:10.1016/j.ijrobp.2007.09.020

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Hummel S, Simpson EL, Hemingway P, Stevenson MD, Rees A. Intensity-modulated radiotherapy for the treatment of prostate cancer: a systematic review and economic evaluation. Health Technol Assess (2010) 14(47):1–108, iii–iv. doi:10.3310/hta14470

CrossRef Full Text | Google Scholar

9. Alicikus ZA, Yamada Y, Zhang Z, Pei X, Hunt M, Kollmeier M, et al. Ten-year outcomes of high-dose, intensity-modulated radiotherapy for localized prostate cancer. Cancer (2011) 117(7):1429–37. doi:10.1002/cncr.25467

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Bernard JR, Buskirk SJ, Heckman MG, Diehl NN, Ko SJ, Macdonald OK, et al. Salvage radiotherapy for rising prostate-specific antigen levels after radical prostatectomy for prostate cancer: dose-response analysis. Int J Radiat Oncol Biol Phys (2010) 76(3):735–40. doi:10.1016/j.ijrobp.2009.02.049

CrossRef Full Text | Google Scholar

11. King CR. The dose-response of salvage radiotherapy following radical prostatectomy: a systematic review and meta-analysis. Radiother Oncol (2016) 121(2):199–203. doi:10.1016/j.radonc.2016.10.026

CrossRef Full Text | Google Scholar

12. Herrera FG, Berthold DR. Radiation therapy after radical prostatectomy: implications for clinicians. Front Oncol (2016) 6:117. doi:10.3389/fonc.2016.00117

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Beck M, Barelkowski T, Kaul D, Wecker S, Thieme AH, Zwahlen DR, et al. Role of dose intensification for salvage radiation therapy after radical prostatectomy. Front Oncol (2016) 6:48. doi:10.3389/fonc.2016.00048

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Goenka A, Magsanoc JM, Pei X, Schechter M, Kollmeier M, Cox B, et al. Improved toxicity profile following high-dose postprostatectomy salvage radiation therapy with intensity-modulated radiation therapy. Eur Urol (2011) 60(6):1142–8. doi:10.1016/j.eururo.2011.08.006

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Raziee H, Berlin A. Gaps between evidence and practice in postoperative radiotherapy for prostate cancer: focus on toxicities and the effects on health-related quality of life. Front Oncol (2016) 6:70. doi:10.3389/fonc.2016.00070

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Goineau A, d’Aillières B, de Decker L, Supiot S. Integrating geriatric assessment into decision-making after prostatectomy: adjuvant radiotherapy, salvage radiotherapy, or none? Front Oncol (2015) 5:227. doi:10.3389/fonc.2015.00227

PubMed Abstract | CrossRef Full Text | Google Scholar

17. van Herk M, Remeijer P, Lebesque JV. Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol (2002) 52(5):1407–22. doi:10.1016/S0360-3016(01)02805-X

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Fiorino C, Foppiano F, Franzone P, Broggi S, Castellone P, Marcenaro M, et al. Rectal and bladder motion during conformal radiotherapy after radical prostatectomy. Radiother Oncol (2005) 74(2):187–95. doi:10.1016/j.radonc.2004.10.002

PubMed Abstract | CrossRef Full Text | Google Scholar

19. de Crevoisier R, Tucker SL, Dong L, Mohan R, Cheung R, Cox JD, et al. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys (2005) 62(4):965–73. doi:10.1016/j.ijrobp.2004.11.032

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Potters L, Gaspar LE, Kavanagh B, Galvin JM, Hartford AC, Hevezi JM, et al. American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guidelines for image-guided radiation therapy (IGRT). Int J Radiat Oncol Biol Phys (2010) 76(2):319–25. doi:10.1016/j.ijrobp.2009.09.042

CrossRef Full Text | Google Scholar

21. Korreman S, Rasch C, McNair H, Verellen D, Oelfke U, Maingon P, et al. The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide. Radiother Oncol (2010) 94(2):129–44. doi:10.1016/j.radonc.2010.01.004

CrossRef Full Text | Google Scholar

22. Haworth A, Paneghel A, Herschtal A, Duchesne G, Williams S, Tai KH, et al. Verification of target position in the post-prostatectomy cancer patient using cone beam CT. J Med Imaging Radiat Oncol (2009) 53(2):212–20. doi:10.1111/j.1754-9485.2009.02057.x

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Klayton T, Price R, Buyyounouski MK, Sobczak M, Greenberg R, Li J, et al. Prostate bed motion during intensity-modulated radiotherapy treatment. Int J Radiat Oncol Biol Phys (2012) 84(1):130–6. doi:10.1016/j.ijrobp.2011.11.041

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Ost P, De Meerleer G, De Gersem W, Impens A, De Neve W. Analysis of prostate bed motion using daily cone-beam computed tomography during postprostatectomy radiotherapy. Int J Radiat Oncol Biol Phys (2011) 79(1):188–94. doi:10.1016/j.ijrobp.2009.10.029

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Simpson DR, Einck JP, Nath SK, Sethi RA, Wang JZ, Mundt AJ, et al. Comparison of daily cone-beam computed tomography and kilovoltage planar imaging for target localization in prostate cancer patients following radical prostatectomy. Pract Radiat Oncol (2011) 1(3):156–62. doi:10.1016/j.prro.2010.12.002

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Liu F, Ahunbay E, Lawton C, Li XA. Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy. Med Phys (2014) 41(3):031710. doi:10.1118/1.4866222

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Chinnaiyan P, Tomée W, Patel R, Chappell R, Ritter M. 3D-ultrasound guided radiation therapy in the post-prostatectomy setting. Technol Cancer Res Treat (2003) 2(5):455–8. doi:10.1177/153303460300200511

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Fargier-Voiron M, Presles B, Pommier P, Munoz A, Rit S, Sarrut D, et al. Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization. Phys Med (2015) 31(8):997–1004. doi:10.1016/j.ejmp.2015.07.147

CrossRef Full Text | Google Scholar

29. Fargier-Voiron M, Presles B, Pommier P, Munoz A, Rit S, Sarrut D, et al. Evaluation of a new transperineal ultrasound probe for inter-fraction image-guidance for definitive and post-operative prostate cancer radiotherapy. Phys Med (2016) 32(3):499–505. doi:10.1016/j.ejmp.2016.01.481

CrossRef Full Text | Google Scholar

30. Ramiandrisoa F, Duvergé L, Castelli J, Nguyen TD, Servagi-Vernat S, de Crevoisier R. [Clinical to planning target volume margins in prostate cancer radiotherapy]. Cancer Radiother (2016) 20(6–7):629–39. doi:10.1016/j.canrad.2016.07.095

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Sandhu A, Sethi R, Rice R, Wang J-Z, Marcus L, Salem C, et al. Prostate bed localization with image-guided approach using on-board imaging: reporting acute toxicity and implications for radiation therapy planning following prostatectomy. Radiother Oncol (2008) 88(1):20–5. doi:10.1016/j.radonc.2008.05.009

CrossRef Full Text | Google Scholar

32. Song S, Yenice KM, Kopec M, Liauw SL. Image-guided radiotherapy using surgical clips as fiducial markers after prostatectomy: a report of total setup error, required PTV expansion, and dosimetric implications. Radiother Oncol (2012) 103(2):270–4. doi:10.1016/j.radonc.2011.07.024

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Huang K, Palma DA, Scott D, McGregor D, Gaede S, Yartsev S, et al. Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy. Int J Radiat Oncol Biol Phys (2012) 84(2):402–7. doi:10.1016/j.ijrobp.2011.12.035

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Bell LJ, Cox J, Eade T, Rinks M, Kneebone A. Prostate bed motion may cause geographic miss in post-prostatectomy image-guided intensity-modulated radiotherapy. J Med Imaging Radiat Oncol (2013) 57(6):725–32. doi:10.1111/1754-9485.12089

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Kupelian PA, Langen KM, Willoughby TR, Wagner TH, Zeidan OA, Meeks SL. Daily variations in the position of the prostate bed in patients with prostate cancer receiving postoperative external beam radiation therapy. Int J Radiat Oncol Biol Phys (2006) 66(2):593–6. doi:10.1016/j.ijrobp.2006.05.071

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Cavalieri R, Gay HA, Liu J, Ferreira MC, Mota HC, Sibata CH, et al. Total error shift patterns for daily CT on rails image-guided radiotherapy to the prostate bed. Radiat Oncol (2011) 6:142. doi:10.1186/1748-717X-6-142

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Langenhuijsen JF, Donker R, McColl GM, Kiemeney LA, Witjes JA, van Lin EN. Postprostatectomy ultrasound-guided transrectal implantation of gold markers for external beam radiotherapy. Technique and complications rate. Strahlenther Onkol (2013) 189(6):476–81. doi:10.1007/s00066-013-0323-4

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Fortin I, Carrier J-F, Beauchemin M-C, Béliveau-Nadeau D, Delouya G, Taussky D. Using fiducial markers in the prostate bed in postprostatectomy external beam radiation therapy improves accuracy over surgical clips. Strahlenther Onkol (2014) 190(5):46771. doi:10.1007/s00066-014-0631-3

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Ålander E, Visapää H, Kouri M, Keyriläinen J, Saarilahti K, Tenhunen M. Gold seed fiducials in analysis of linear and rotational displacement of the prostate bed. Radiother Oncol (2014) 110(2):256–60. doi:10.1016/j.radonc.2013.10.037

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Schiffner DC, Gottschalk AR, Lometti M, Aubin M, Pouliot J, Speight J, et al. Daily electronic portal imaging of implanted gold seed fiducials in patients undergoing radiotherapy after radical prostatectomy. Int J Radiat Oncol Biol Phys (2007) 67(2):610–9. doi:10.1016/j.ijrobp.2006.09.042

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Balter JM, Wright JN, Newell LJ, Friemel B, Dimmer S, Cheng Y, et al. Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys (2005) 61(3):933–7. doi:10.1016/j.ijrobp.2004.11.009

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Willoughby TR, Kupelian PA, Pouliot J, Shinohara K, Aubin M, Roach M, et al. Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys (2006) 65(2):528–34. doi:10.1016/j.ijrobp.2006.01.050

PubMed Abstract | CrossRef Full Text | Google Scholar

43. Li XA, Yu C, Holmes T. A systematic evaluation of air cavity dose perturbation in megavoltage x-ray beams. Med Phys (2000) 27(5):1011–7. doi:10.1118/1.598966

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Pinkawa M, Siluschek J, Gagel B, Demirel C, Asadpour B, Holy R, et al. Influence of the initial rectal distension on posterior margins in primary and postoperative radiotherapy for prostate cancer. Radiother Oncol (2006) 81(3):284–90. doi:10.1016/j.radonc.2006.10.028

PubMed Abstract | CrossRef Full Text | Google Scholar

45. O’Doherty UM, McNair HA, Norman AR, Miles E, Hooper S, Davies M, et al. Variability of bladder filling in patients receiving radical radiotherapy to the prostate. Radiother Oncol (2006) 79(3):335–40. doi:10.1016/j.radonc.2006.05.007

PubMed Abstract | CrossRef Full Text | Google Scholar

46. Bell LJ, Cox J, Eade T, Rinks M, Kneebone A. The impact of rectal and bladder variability on target coverage during post-prostatectomy intensity modulated radiotherapy. Radiother Oncol (2014) 110(2):245–50. doi:10.1016/j.radonc.2013.10.042

PubMed Abstract | CrossRef Full Text | Google Scholar

47. Smitsmans MHP, Pos FJ, de Bois J, Heemsbergen WD, Sonke J-J, Lebesque JV, et al. The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients. Int J Radiat Oncol Biol Phys (2008) 71(4):1279–86. doi:10.1016/j.ijrobp.2008.03.036

PubMed Abstract | CrossRef Full Text | Google Scholar

48. Lips IM, Kotte ANTJ, van Gils CH, van Leerdam ME, van der Heide UA, van Vulpen M. Influence of antiflatulent dietary advice on intrafraction motion for prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys (2011) 81(4):e401–6. doi:10.1016/j.ijrobp.2011.04.062

PubMed Abstract | CrossRef Full Text | Google Scholar

49. Nichol AM, Warde PR, Lockwood GA, Kirilova AK, Bayley A, Bristow R, et al. A cinematic magnetic resonance imaging study of milk of magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion. Int J Radiat Oncol Biol Phys (2010) 77(4):1072–8. doi:10.1016/j.ijrobp.2009.06.005

PubMed Abstract | CrossRef Full Text | Google Scholar

50. Oates RW, Schneider ME, Lim Joon M, McPhee NJ, Jones DK, Foroudi F, et al. A randomised study of a diet intervention to maintain consistent rectal volume for patients receiving radical radiotherapy to the prostate. Acta Oncol (2014) 53(4):569–71. doi:10.3109/0284186X.2013.854927

CrossRef Full Text | Google Scholar

51. Ki Y, Kim W, Nam J, Kim D, Lee J, Park D, et al. Probiotics for rectal volume variation during radiation therapy for prostate cancer. Int J Radiat Oncol Biol Phys (2013) 87(4):646–50. doi:10.1016/j.ijrobp.2013.07.038

PubMed Abstract | CrossRef Full Text | Google Scholar

52. Di Stefano M, Miceli E, Gotti S, Missanelli A, Mazzocchi S, Corazza GR. The effect of oral alpha-galactosidase on intestinal gas production and gas-related symptoms. Dig Dis Sci (2007) 52(1):78–83. doi:10.1007/s10620-006-9296-9

PubMed Abstract | CrossRef Full Text | Google Scholar

53. Yahya S, Zarkar A, Southgate E, Nightingale P, Webster G. Which bowel preparation is best? Comparison of a high-fibre diet leaflet, daily microenema and no preparation in prostate cancer patients treated with radical radiotherapy to assess the effect on planned target volume shifts due to rectal distension. Br J Radiol (2013) 86(1031):20130457. doi:10.1259/bjr.20130457

PubMed Abstract | CrossRef Full Text | Google Scholar

54. Ogino I, Uemura H, Inoue T, Kubota Y, Nomura K, Okamoto N. Reduction of prostate motion by removal of gas in rectum during radiotherapy. Int J Radiat Oncol Biol Phys (2008) 72(2):456–66. doi:10.1016/j.ijrobp.2008.01.004

PubMed Abstract | CrossRef Full Text | Google Scholar

55. Diot Q, Olsen C, Kavanagh B, Raben D, Miften M. Impact of anatomical interventions on the localization of post-prostatectomy cancer patients. Med Phys (2010) 37(2):629–37. doi:10.1118/1.3284249

PubMed Abstract | CrossRef Full Text | Google Scholar

56. Diot Q, Olsen C, Kavanagh B, Raben D, Miften M. Dosimetric effect of online image-guided anatomical interventions for postprostatectomy cancer patients. Int J Radiat Oncol Biol Phys (2011) 79(2):623–32. doi:10.1016/j.ijrobp.2010.04.020

PubMed Abstract | CrossRef Full Text | Google Scholar

57. Ghilezan MJ, Jaffray DA, Siewerdsen JH, Van Herk M, Shetty A, Sharpe MB, et al. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). Int J Radiat Oncol Biol Phys (2005) 62(2):406–17. doi:10.1016/j.ijrobp.2003.10.017

CrossRef Full Text | Google Scholar

58. Padhani AR, Khoo VS, Suckling J, Husband JE, Leach MO, Dearnaley DP. Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. Int J Radiat Oncol Biol Phys (1999) 44(3):525–33. doi:10.1016/S0360-3016(99)00040-1

PubMed Abstract | CrossRef Full Text | Google Scholar

59. de Leon JF, Jameson MG, Windsor A, Cloak K, Keats S, Vial P, et al. Superior target volume and organ stability with the use of endorectal balloons in post-prostatectomy radiotherapy. J Med Imaging Radiat Oncol (2015) 59(4):507–13. doi:10.1111/1754-9485.12300

PubMed Abstract | CrossRef Full Text | Google Scholar

60. Jameson MG, De Leon J, Windsor AA, Cloak K, Keats S, Dowling JA, et al. Endorectal balloons in the post prostatectomy setting: do gains in stability lead to more predictable dosimetry? Radiother Oncol (2013) 109(3):493–7. doi:10.1016/j.radonc.2013.08.024

PubMed Abstract | CrossRef Full Text | Google Scholar

61. Smeenk RJ, van Lin EN, van Kollenburg P, McColl GM, Kunze-Busch M, Kaanders JH. Endorectal balloon reduces anorectal doses in post-prostatectomy intensity-modulated radiotherapy. Radiother Oncol (2011) 101(3):465–70. doi:10.1016/j.radonc.2011.07.019

PubMed Abstract | CrossRef Full Text | Google Scholar

62. Smeenk RJ, Teh BS, Butler EB, van Lin EN, Kaanders JH. Is there a role for endorectal balloons in prostate radiotherapy? A systematic review. Radiother Oncol (2010) 95(3):277–82. doi:10.1016/j.radonc.2010.04.016

PubMed Abstract | CrossRef Full Text | Google Scholar

63. Ishiyama H, Teh BS, Blanco AI, Paulino AC, Mai W-Y, Caillouet J, et al. Salvage intensity modulated radiotherapy using endorectal balloon after radical prostatectomy: clinical outcomes. Int J Urol (2013) 20(12):1178–83. doi:10.1111/iju.12145

CrossRef Full Text | Google Scholar

64. Effect of ProSpare (PS), a rectal obturator, on inter- and intrafraction prostate motion and anorectal doses in prostate radiotherapy (RT). J Clin Oncol (2016). Available from: http://meetinglibrary.asco.org/content/158265-172

Google Scholar

65. Murray JR, McNair HA, Dearnaley DP. Rationale and development of image-guided intensity-modulated radiotherapy post-prostatectomy: the present standard of care? Cancer Manag Res (2015) 7:331–44. doi:10.2147/CMAR.S51955

PubMed Abstract | CrossRef Full Text | Google Scholar

66. Zilli T, Benz E, Miralbell R. [Prostate-rectum spacers: optimization of prostate cancer irradiation]. Cancer Radiothér (2014) 18(3):215–21; quiz 243–4, 247. doi:10.1016/j.canrad.2014.03.001

CrossRef Full Text | Google Scholar

67. Susil RC, McNutt TR, DeWeese TL, Song D. Effects of prostate-rectum separation on rectal dose from external beam radiotherapy. Int J Radiat Oncol Biol Phys (2010) 76(4):1251–8. doi:10.1016/j.ijrobp.2009.07.1679

PubMed Abstract | CrossRef Full Text | Google Scholar

68. Rouzaud M, Zilli T, Vallée JP, Weber DC, Miralbell R. EP-1261: impact of polyethylen glycol spacer injections on interfraction prostate motion in patients undergoing IGRT. Radiother Oncol (2013) 106:S476–7. doi:10.1016/S0167-8140(15)33567-2

CrossRef Full Text | Google Scholar

69. Picardi C, Rouzaud M, Kountouri M, Lestrade L, Vallée JP, Caparrotti F, et al. Impact of hydrogel spacer injections on interfraction prostate motion during prostate cancer radiotherapy. Acta Oncol (2016) 55(7):834–8. doi:10.3109/0284186X.2015.1128118

PubMed Abstract | CrossRef Full Text | Google Scholar

70. Juneja P, Kneebone A, Booth JT, Thwaites DI, Kaur R, Colvill E, et al. Prostate motion during radiotherapy of prostate cancer patients with and without application of a hydrogel spacer: a comparative study. Radiat Oncol (2015) 10:215. doi:10.1186/s13014-015-0526-1

PubMed Abstract | CrossRef Full Text | Google Scholar

71. Pinkawa M, Piroth MD, Holy R, Escobar-Corral N, Caffaro M, Djukic V, et al. Spacer stability and prostate position variability during radiotherapy for prostate cancer applying a hydrogel to protect the rectal wall. Radiother Oncol (2013) 106(2):220–4. doi:10.1016/j.radonc.2012.11.010

PubMed Abstract | CrossRef Full Text | Google Scholar

72. Pinkawa M. Current role of spacers for prostate cancer radiotherapy. World J Clin Oncol (2015) 6(6):189–93. doi:10.5306/wjco.v6.i6.189

PubMed Abstract | CrossRef Full Text | Google Scholar

73. Mok G, Benz E, Vallee J-P, Miralbell R, Zilli T. Optimization of radiation therapy techniques for prostate cancer with prostate-rectum spacers: a systematic review. Int J Radiat Oncol Biol Phys (2014) 90(2):278–88. doi:10.1016/j.ijrobp.2014.06.044

PubMed Abstract | CrossRef Full Text | Google Scholar

74. Pinkawa M, Schubert C, Escobar-Corral N, Holy R, Eble MJ. Application of a hydrogel spacer for postoperative salvage radiotherapy of prostate cancer. Strahlenther Onkol (2015) 191(4):375–9. doi:10.1007/s00066-014-0769-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: post-prostatectomy, prostate neoplasm, radiotherapy, image-guided radiotherapy, spacers, endorectal balloons, diet protocol

Citation: Vilotte F, Antoine M, Bobin M, Latorzeff I, Supiot S, Richaud P, Thomas L, Leduc N, Guérif S, Iriondo-Alberdi J, de Crevoisier R and Sargos P (2017) Post-Prostatectomy Image-Guided Radiotherapy: The Invisible Target Concept. Front. Oncol. 7:34. doi: 10.3389/fonc.2017.00034

Received: 26 January 2017; Accepted: 24 February 2017;
Published: 09 March 2017

Edited by:

Fabio Grizzi, Humanitas Clinical and Research Center, Italy

Reviewed by:

Kouji Izumi, Kanazawa University, Japan
Mohamed Saad Zaghloul, Cairo University, Egypt

Copyright: © 2017 Vilotte, Antoine, Bobin, Latorzeff, Supiot, Richaud, Thomas, Leduc, Guérif, Iriondo-Alberdi, de Crevoisier and Sargos. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Paul Sargos, p.sargos@bordeaux.unicancer.fr

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.