Staged Hybrid Techniques With Straightforward Bypass Surgery Followed by Flow Diverter Deployment for Complex Recurrent Middle Cerebral Artery Aneurysms

Jun Tanabe* Ichiro Nakahara Shoji Matsumoto Jun Morioka Akiko Hasebe Sadayoshi Watanabe Kenichiro Suyama Kiyonori Kuwahara
  • Department of Comprehensive Strokology, Fujita Health University School of Medicine, Toyoake, Japan

Background: Recurrent complex middle cerebral artery (MCA) aneurysms after combined clipping and endovascular surgery are challenging, and if conventional techniques are adapted, advanced surgical, endovascular, and a combination of both techniques are often required. For such complex aneurysms, safe and effective straightforward techniques for all neurovascular surgeons are warranted. We describe the details of staged hybrid techniques with straightforward bypass surgery followed by flow diverter deployment in a patient with complex MCA aneurysm.

Illustrative Case: A 69-year-old woman presented with left recurrent large MCA aneurysm enlargement 25 years after direct surgery and coil embolization for ruptured aneurysm. The recurrent MCA aneurysm had large and complex morphology and was adhering to the brain tissues. Therefore, it was unsuitable to treat such aneurysm with conventional surgical and endovascular techniques with a high risk of morbidity. We performed (1) M2 ligation following superficial temporal artery-M2 bypass and (2) flow diverter deployment assisted with coil packing in two sessions. Three months after the second session, the aneurysm was completely occluded with endothelialization of the neck. Angiographic findings revealed no recurrence 12 months after the treatment.

Conclusions: Staged hybrid techniques with straightforward bypass surgery followed by flow diverter deployment may be a safe and effective treatment for complex recurrent MCA aneurysms.

Introduction

Recurrent complex middle cerebral artery (MCA) aneurysms after clipping and endovascular surgery are challenging because advanced direct surgery and endovascular techniques are often required (18). For such complex aneurysms, safe and effective straightforward techniques for all neurovascular surgeons are warranted. We describe a staged hybrid technique characterized by M2 ligation following superficial temporal artery (STA)-M2 bypass and flow diverter (FD) deployment assisted with coil packing for recurrent complex large MCA aneurysm.

Illustrative Case

Clinical Presentation

A 69-year-old woman presented with left recurrent large MCA aneurysm enlargement 25 years after direct surgery and coil embolization for a ruptured aneurysm. For the initial treatment of a ruptured aneurysm 25 years previously, neck clipping was attempted, but she received only a coating due to the aneurysm's unclippable morphology. Subsequently, coil embolization was performed using a simple technique. Nine years after the initial treatment, an additional coil was inserted, owing to coil compaction. Twenty-three years after the initial treatment, regrowth of the aneurysm was detected; however, conservative treatment was selected because of treatment difficulty. Two years later, she was referred to us for treatment of further rapid enlargement. Angiography revealed aneurysm regrowth (12 × 8 × 6 mm) unrelated to the previous coil mesh (Figure 1). The STA-parietal branch was sacrificed at initial treatment before 25 years, and the STA-frontal branch (FB-STA) was preserved with a small caliber. It was unsuitable to treat such an aneurysm with conventional surgical or endovascular techniques because previous coil mesh protruded from outside of the aneurysm, and firm adhesion of the aneurysm to the surrounding brain tissue was a concern. Hybrid-combined therapy with direct surgery and endovascular treatment was performed in two sessions: (1) FB-STA and M2-superior trunk, originating from the aneurysm with a steep angle, followed by ligation of the M2-superior trunk proximal to the bypass, and (2) FD deployment following coil embolization.

FIGURE 1
www.frontiersin.org

Figure 1. Left internal carotid angiography reveals recurrent large middle cerebral artery aneurysm unrelated to a previous coil. (A) In an antero-posterior view. (B) In a lateral view.

Treatment and Technique

In the first session, frontotemporal craniotomy was performed using a previous skin incision and bone flap. FB-STA was harvested with a direct cut down on the artery behind the skin flap. The Sylvian fissure was widely dissected, revealing the M2/M3 portion (9, 10). It was difficult to fully expose the aneurysm because the aneurysm was strongly adherent to the surrounding brain tissue, coating material, and previously extruded coil mesh. Therefore, the superior branch of the M2 was exposed. FB-STA and M2 bypass were performed, and the patency of the bypass was confirmed using indocyanine green videoangiography. Thereafter, the M2 proximal to the bypass was ligated (Figure 2). Trans-cranial motor-evoked potential (MEP) was intact for 10 min after M2 ligation, and cranial closure was performed. The MEP was intact until the end of the surgery, approximately 60 min after M2 ligation. Thus, the recurrent MCA aneurysm was transformed to a side-wall-type aneurysm (Figure 3).

FIGURE 2
www.frontiersin.org

Figure 2. Left: Preoperative three-dimensional rotational angiography, describing the aneurysm estimated for an operative view. The arrow indicates the bypass site, and the arrowhead indicates the ligation point. Right: A frontal branch of the superficial temporal artery and M2 bypass followed by ligation of M2 proximal to bypass.

FIGURE 3
www.frontiersin.org

Figure 3. Postoperative angiography of first session reveals sacrifice of superior trunk “that is transformation to side-wall-type aneurysm” (left) and good patency of bypass (right).

In the second session, 3 weeks after the first session, endovascular therapy was performed. The patient received dual antiplatelet therapy for 2 weeks before the procedure. An 8-Fr guiding catheter was introduced into the left internal carotid artery. A 6-Fr distal access catheter (SOFIA SELECT; MicroVention-Terumo, Tustin, California, USA) was navigated into the IC top. Coils were roughly inserted through the microcatheter (Phenom 17; Medtronic, Minneapolis, MN, USA) with balloon assistance (Scepter XC; 4. mm in diameter, 11 mm in length; Microvention-Terumo). The balloon catheter was exchanged with a microcatheter for FD deployment (Headway 27; MicroVention-Terumo) with a long microguide wire (CHIKAI, 300-cm length; Asahi Intecc, Nagoya, Aichi, Japan). An FD [flow redirection endoluminal device (FRED) 3.5 mm in diameter, 13/11 mm in length; MicroVention-Terumo] was deployed from the M2 posterior trunk to the M1, covering the aneurysm neck. Immediately after FD deployment, the aneurysm was subtotally filled (O' Kelly-Marotta grading scale B). The aneurysm became even more side wall type because FD deployment straightened the artery from the M2 posterior trunk to M1 (Figure 4). The operative technique is presented in the surgical video (Supplementary Material).

FIGURE 4
www.frontiersin.org

Figure 4. (A) Flow diverter deployment following coil insertion in the antero-posterior view. Coil embolization is performed with ten detachable coils (Barricade complex framing; Blockade Medical, Irvine, California, USA, Axium Prime 3D; Medtronic). (B) In a lateral view. The aneurysm underwent a subtotal filling, and the artery, where flow diverter (FD) was deployed, was slightly straightened.

Outcomes and Follow-Up

The patient recovered without symptomatic complications in both the procedures. No high-intensity signal, including the territory of the perforator, such as the lenticulostriate artery (LSA), appeared on the diffusion-weighted image. Three months after the second treatment session, the aneurysm was completely occluded with neck endothelialization (O'Kelly-Marotta grading scale D) by follow-up digital subtraction angiography (Figure 5) (11). Angiography revealed no recurrence 12 months after the treatment. Dual antiplatelet therapy was maintained for 6 months, and single-agent therapy was discontinued 12 months after the treatment.

FIGURE 5
www.frontiersin.org

Figure 5. Left internal carotid angiography 3 months after treatment reveals complete occlusion of the aneurysm with endothelialization of the neck. (A) In an antero-posterior view. (B) In a lateral view.

Discussion

Principle of a Present Staged Strategy

The present study described staged hybrid techniques characterized by debranching the artery planned to be jailed by FD using low-flow bypass and FD deployment for complex bifurcation aneurysms (Figure 6). To promote early healing, adjunctive coil embolization was performed because the presented aneurysm had short-term aggressive enlargement. Thus, the aneurysm was completely occluded in the short term.

FIGURE 6
www.frontiersin.org

Figure 6. Schematic illustration depicting the present techniques.

Combined surgical and endovascular techniques for complex aneurysms have been reported (12, 13). Before FD treatment, transformation from a bifurcation aneurysm to a side wall aneurysm by side-to-side M2 anastomosis followed by coil embolization of the M2 has been a minimally invasive approach (14). Technical characteristics, safety, and effectiveness have been reported regarding side-to-side anastomosis (15, 16). However, it is difficult to make a suitable surgical field for side-to-side anastomosis in retreatment situations due to tissue adhesion. Side-to-side anastomosis requires advanced technical skills and risks the occlusion of both arteries, resulting in major ischemic complications. In contrast, low-flow bypass sufficiently supplies blood flow to one side of the M2 territory with electrophysiological monitoring and is a familiar technique for many neurovascular surgeons. In addition, technical advancements in endovascular devices have allowed easier and safer FD deployment. Therefore, among the various combined surgical and endovascular techniques for complex recurrent MCA aneurysms, this staged hybrid technique with low-flow bypass and FD deployment may comprise the preferred treatment option.

Concerns of Conventional and Another Recent Advanced Treatment

Microsurgical clipping and endovascular treatment are challenging in complex aneurysms, including aneurysms that lack a neck, which have a large size, and have been treated previously. Consequently, in the conventional strategy, trapping or proximal occlusion for flow alteration was adopted following bypass surgery, including high flow bypass using an interposition graft such as a radial artery or saphenous vein. However, uncertain aneurysm occlusion in flow alteration treatment, cerebral infarction due to graft occlusion, and hyperperfusion for high-flow bypass have been a concern (13). In contrast, endovascular techniques, including even FD deployment, have the risk of incomplete occlusion and recurrence, especially in complex large MCA bifurcation aneurysms (47, 17).

In recent years, novel endovascular devices have become available for wide-neck bifurcation aneurysms, such as PulseRider and Woven EndoBridge devices (18, 19). However, the use of these devices for aneurysms with a steep parent artery-aneurysm angle, previous coil mesh, or thrombus is contraindicated.

Advantage of FD Deployment Following Transformed Aneurysm Morphology

We proposed that FD should be deployed following the sacrifice of the jailed M2 after STA-MCA bypass for complex MCA aneurysm. FD has been increasingly used in endovascular treatment of distal anterior circulation aneurysms for treatment efficacy (5, 7, 20, 21). Especially for giant and large aneurysms, FD treatment provides a higher complete occlusion rate at follow-up and a lower recurrence rate than stent-assisted coiling, while the immediate occlusion rate is similar for both treatments (residual aneurysm in almost cases) (22). In the FD treatment for MCA aneurysms, subsequent infarction of the LSA territory after FD deployment is not a major concern under suitable antiplatelet management based on previous reports and clinical experiences of FD in more than a decade (23). However, MCA location has been an independent factor associated with lower occlusion rate, and the FD treatment for MCA bifurcation aneurysms has not been suitable unless conventional treatment options are ineffective (46). In an experimental study, incomplete occlusion following FD deployment for bifurcation aneurysms can be caused by persistent flow of the jailed artery (17). Therefore, combined treatment with branch occlusion for FD deployment is recommended. Transforming a bifurcation aneurysm to a sidewall type using our staged strategy facilitates neo-endothelialization after FD deployment, resulting in long-term stability of aneurysm occlusion.

Conclusion

We present a case in which staged hybrid techniques with straightforward bypass surgery followed by FD deployment were introduced to successfully obliterate complex recurrent MCA aneurysms 25 years after direct surgery and coil embolization. This strategy may be safe and effective, and, comprising the preferred treatment option for complex MCA aneurysms, it could be widely adopted by neurovascular surgeons.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics Statement

Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author Contributions

JT and IN contributed conception and design of the study and wrote sections of the manuscript. JT, IN, SM, JM, AH, SW, KS, and KK contributed to the acquisition and analysis of the data. JT wrote the first draft of the manuscript. All authors contributed to manuscript revision, read, and approved the submitted version.

Conflict of Interest

IN reports grants from Kaneka Medix, Medtronic, and Nipro, consultancy from Kaneka Medix, and Medicos Hirata, outside the submitted work.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Acknowledgments

We express our gratitude to Dr. Yoshio Suyama, Department of Neurosurgery, Baba Memorial Hospital, for his invaluable support of this study.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fsurg.2022.824236/full#supplementary-material

Supplementary Video. Staged hybrid techniques with straightforward bypass surgery followed by flow diverter deployment for complex recurrent middle cerebral artery aneurysms: The operative technique demonstration of the illustrative case.

References

1. Matsukawa H, Tanikawa R, Kamiyama H, Tsuboi T, Noda K, Ota N, et al. Risk factors for neurological worsening and symptomatic watershed infarction in internal carotid artery aneurysm treated by extracranial-intracranial bypass using radial artery graft. J Neurosurg. (2016) 125:239–46. doi: 10.3171/2015.5.JNS142524

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Diaz FG, Pearce J, Ausman JI. Complications of cerebral revascularization with autogenous vein grafts. Neurosurgery. (1985) 17:271–6. doi: 10.1227/00006123-198508000-00004

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Sekhar LN, Duff JM, Kalavakonda C, Olding M. Cerebral revascularization using radial artery grafts for the treatment of complex intracranial aneurysms: Techniques and outcomes for 17 patients. Neurosurgery. (2001) 49:646–59. doi: 10.1227/00006123-200109000-00023

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Caroff J, Neki H, Mihalea C, D'Argento F, Abdel Khalek H, Ikka L, et al. Flow-diverter stents for the treatment of saccular middle cerebral artery bifurcation aneurysms. Am J Neuroradiol. (2016) 37:279–84. doi: 10.3174/ajnr.A4540

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Cagnazzo F, Perrini P, Dargazanli C, Lefevre PH, Gascou G, Morganti R, et al. Treatment of unruptured distal anterior circulation aneurysms with flow-diverter stents: a meta-analysis. Am J Neuroradiol. (2019) 40:687–93. doi: 10.3174/ajnr.A6002

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Cagnazzo F, Mantilla D, Lefevre PH, Dargazanli C, Gascou G, Costalat V. Treatment of middle cerebral artery aneurysms with flow- diverter stents: a systematic review and meta-analysis. Am J Neuroradiol. (2017) 38:2289–94. doi: 10.3174/ajnr.A5388

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Michelozzi C, Darcourt J, Guenego A, Januel AC, Tall P, Gawlitza M, et al. Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: Complications, aneurysm sac occlusion, reabsorption, recurrence, and jailed branch modification at follow-up. J Neurosurg. (2019) 131:1751–62. doi: 10.3171/2018.7.JNS18654

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Nussbaum ES, Kallmes KM, Lassig JP, Goddard JK, Madison MT, Nussbaum LA. Cerebral revascularization for the management of complex intracranial aneurysms: A single-center experience. J Neurosurg. (2019) 131:1297–307. doi: 10.3171/2018.4.JNS172752

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Maekawa H, Hadeishi H. Venous-preserving sylvian dissection. World Neurosurg. (2015) 84:2043–52. doi: 10.1016/j.wneu.2015.07.050

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Ishikawa T. What is the role of clipping surgery for ruptured cerebral aneurysms in the endovascular era? A review of recent technical advances and problems to be solved. Neurol Med Chir. (2010) 50:800–8. doi: 10.2176/nmc.50.800

PubMed Abstract | CrossRef Full Text | Google Scholar

11. O'Kelly CJ, Krings T, Fiorella D, Marotta TR, A. novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol. (2010) 16:133–7. doi: 10.1177/159101991001600204

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Hoh BL, Putman CM, Budzik RF, Carter BS, Ogilvy CS. Combined surgical and endovascular techniques of flow alteration to treat fusiform and complex wide-necked intracranial aneurysms that are unsuitable for clipping or coil embolization. J Neurosurg. (2001) 95:24–35. doi: 10.3171/jns.2001.95.1.0024

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Sato K, Endo H, Fujimura M, Endo T, Matsumoto Y, Shimizu H, et al. Endovascular treatments in combination with extracranial-intracranial bypass for complex intracranial aneurysms. World Neurosurg. (2018) 113:e747–60. doi: 10.1016/j.wneu.2018.02.143

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Cenzato M, Dones F, Fratianni A, Piano M, Valvassori L, Cervo A, et al. A minimally invasive approach for giant middle cerebral artery thrombosed aneurysms treatment. J Neurosurg Sci. (2019) doi: 10.23736/S0390-5616.19.04768-4

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Wang L, Cai L, Qian H, Lawton MT, Shi X. The in situ side-to-side bypass technique: a comprehensive review of the technical characteristics, current anastomosis approaches, and surgical experience. World Neurosurg. (2018) 115:357–72. doi: 10.1016/j.wneu.2018.04.173

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Quiñones-Hinojosa A, Lawton MT. In situ bypass in the management of complex intracranial aneurysms: technique application in 13 patients. Neurosurgery. (2005) 57:140–5. doi: 10.1227/01.NEU.0000163599.78896.F4

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Fahed R, Gentric JC, Salazkin I, Gevry G, Raymond J, Darsaut TE. Flow diversion of bifurcation aneurysms is more effective when the jailed branch is occluded: an experimental study in a novel canine model. J Neurointerv Surg. (2017) 9:311–5. doi: 10.1136/neurintsurg-2015-012240

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Spiotta AM, Chaudry MI, Turner RD, Turk AS, Derdeyn CP, Mocco J, et al. An update on the adjunctive neurovascular support of wide-neck aneurysm embolization and reconstruction trial: 1-year safety and angiographic results. Am J Neuroradiol. (2018) 39:848–51. doi: 10.3174/ajnr.A5599

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Arthur AS, Molyneux A, Coon AL, Saatci I, Szikora I, Baltacioglu F, et al. The safety and effectiveness of the woven endobridge (web) system for the treatment of wide-necked bifurcation aneurysms: Final 12-month results of the pivotal web intrasaccular therapy (web-it) study. J Neurointerv Surg. (2019) 11:924–30. doi: 10.1136/neurintsurg-2019-014815

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Killer-Oberpfalzer M, Kocer N, Griessenauer CJ, Janssen H, Engelhorn T, Holtmannspötter M, et al. European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: The european flow-redirection intraluminal device study. Am J Neuroradiol. (2018) 39:841–7. doi: 10.3174/ajnr.A5592

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Pierot L, Spelle L, Berge J, Januel AC, Herbreteau D, Aggour M, et al. SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results. J Neurointerv Surg. (2019) 11:184–9. doi: 10.1136/neurintsurg-2018-014261

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Zhang Y, Zhou Y, Yang P, Liu J, Xu Y, Hong B, et al. Comparison of the flow diverter and stent-assisted coiling in large and giant aneurysms: safety and efficacy based on a propensity score-matched analysis. Eur Radiol. (2016) 26:2369–77. doi: 10.1007/s00330-015-4052-1

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Wagner KM, Srinivasan VM, Srivatsan A, Ghali MGZ, Thomas AJ, Enriquez-Marulanda A, et al. Outcomes after coverage of lenticulostriate vessels by flow diverters: a multicenter experience. J Neurosurg. (2020) 132:473–80. doi: 10.3171/2018.8.JNS18755

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: aneurysm, bypass, endovascular therapy (EVT), hybrid technique, middle cerebral artery aneurysms

Citation: Tanabe J, Nakahara I, Matsumoto S, Morioka J, Hasebe A, Watanabe S, Suyama K and Kuwahara K (2022) Staged Hybrid Techniques With Straightforward Bypass Surgery Followed by Flow Diverter Deployment for Complex Recurrent Middle Cerebral Artery Aneurysms. Front. Surg. 9:824236. doi: 10.3389/fsurg.2022.824236

Received: 29 November 2021; Accepted: 03 January 2022;
Published: 02 February 2022.

Edited by:

Sabino Luzzi, University of Pavia, Italy

Reviewed by:

Lai Fung LI, Queen Mary Hospital, Hong Kong SAR, China
Jorge Marcelo Mura, Instituto de Neurocirugía, Chile

Copyright © 2022 Tanabe, Nakahara, Matsumoto, Morioka, Hasebe, Watanabe, Suyama and Kuwahara. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Jun Tanabe, j.tanabe@fujita-hu.ac.jp

Download